SatLabs Recommendation for a Common Inter-Facility Link for DVB-RCS terminals

Similar documents
HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

OBSOLETE HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

Advanced Test Equipment Rentals ATEC (2832)

High-Value 100 Series (Outdoor)

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

L-BAND FREQUENCY CONVERTER

SYNTHESIZED COMMUNICATION CONVERTERS

HMC7053. Block Upconverters. Typical Applications. General Description. Features. Functional Block Diagram. Satellite communications.

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

MULTIBAND 1/3 RACK-MOUNTED

1/3 RACK-MOUNTED BLOCK CONVERTERS

Multiple Band Outdoor Block Up- and Downconverters

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

ACTIVE IF SPLITTER/COMBINER UHP-IFS

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

2 MHz Lock-In Amplifier

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

Satellite Up- and Downconverter

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Agilent 5345A Universal Counter, 500 MHz

High Performance Outdoor Test Translators

Satellite Up- and Downconverter

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

Datasheet SHF A

Analog & Digital RF-Solutions

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

L-Band Block Upconverter MKT-74 Rev B JULY 2017 Page 1 of 7

DESCRIPTION APPLICATIONS AGILE IF TO L-BAND/RF AZIMUTH SERIES UP/DOWN FREQ CONVERTER NTC/2142

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

4 MHz Lock-In Amplifier

Synthesized Block Up- and Downconverter

SDA 3302 Family. GHz PLL with I 2 C Bus and Four Chip Addresses

Satellite Up- and Downconverter Indoor / Outdoor

Inmarsat Downconverter Narrowband Downconverter

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Instruction Manual Model # Block Upconverter

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

RX40_V1_0 Measurement Report F.Faccio

Product Catalogue January 2018

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

ABE12KX 12 W P1dB Extended Ku-Band BUC USER MANUAL

Advanced Test Equipment Rentals ATEC (2832)

R3267/3273 Spectrum Analyzers

PSM-2100L Satellite Modem L-Band IF Addendum

Synthesized Clock Generator

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

DSM GHz Linear Chirping Source

SATCOM FIBER OPTIC PRODUCTS

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

USB-TG124A Tracking Generator User Manual

L-Band IF Interface Unit

DVO700 P FIBRE OPTIC TRANSMITTER

Modular Block Converter Systems

16W Ku-band Matchbox BUC

Noise Detector ND-1 Operating Manual

GEOSYNC. CAPABILITIES and PRODUCTS CATALOG. Outdoor Mounted. Rack Mounted. Converter Module. Block Converters, L-Band to Transponder Frequency

HDO701 FIBRE OPTIC TRANSMITTER

-Preliminary- Ku-band PLL LNB - Internal Reference (L.O. Stability: ±1 ppm) - MODEL No. NJR2835U/36U/37U/39U series

Synthesized Block Up- and Downconverter Indoor / Outdoor

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD

Instruction Manual Model BlockUpconverter

Typical applications:

SMPTE STANDARD Gb/s Signal/Data Serial Interface. Proposed SMPTE Standard for Television SMPTE 424M Date: < > TP Rev 0

Wideband LNB: 2.4 GHz

REPORT ITU-R M Characteristics of terrestrial IMT-2000 systems for frequency sharing/interference analyses

Norsat SigmaLink. Innovative Communication Solutions. Flexible. Intelligent. Rugged. The Norsat Advantage. Intelligent. Rugged.

Instrumentation Grade RF & Microwave Subsystems

2 MHz Lock-In Amplifier

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

EX04-000D. DVB-T/2xT/T2 MODULATOR DVB MODULATOR

DA : Series of Narrowband or Wideband Distribution Amplifiers

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

X-Band Redundant LNB Systems

Features. PFD Output Voltage 2000 mv, Pk - Pk. PFD Gain Gain = Vpp / 2π Rad khz 100 MHz Square Wave Ref.

Application Note DT-AN-2115B-1. DTA-2115B Verification of Specifations

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

RF Mogul. Quick Start. Model: SDC1. Satellite Dish Controller

Instruction Manual Model Block Downconverter

INTEGRATED CIRCUITS DATA SHEET. TDA4510 PAL decoder. Product specification File under Integrated Circuits, IC02

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

Ku-Band Redundant LNB Systems

ThinkRF D GHz RF Downconverter

SAT IF distribution system

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

Application Note DT-AN DTU-315 Verification of Specifications

ZLNB101 DUAL POLARISATION SWITCH TWIN LNB MULTIPLEX CONTROLLER ISSUE 1- JANUARY 2001 DEVICE DESCRIPTION FEATURES APPLICATIONS

Transcription:

SatLabs Recommendation for a Common Inter-Facility Link for DVB-RCS terminals Version 1.6-06/01/2005 This document is the result of a cooperative effort undertaken by the SatLabs Group. Neither the SatLabs Group nor any member organisation is responsible for any liability of any nature whatsoever resulting from or arising out of use or reliance upon this document by any party. This document is furnished on an as is basis and neither the SatLabs Group nor its members provide any representation or warranty, express or implied, regarding its accuracy, completeness, or fitness for a particular purpose. SatLabs Group 2005. All rights reserved info@satlabs.org http://www.satlabs.org

Content Foreword 3 1 Introduction 4 2 RX IF specification 4 3 TX IFL functionality 5 4 TX IFL specification 5 4.1 IF frequency scheme 5 4.2 IFL system specification 6 5 BUC LO frequency reference system 6 5.1 Internal Reference system specification 7 5.2 External Reference system specification 7 6 BUC DiSEqC signaling 8 6.1 Physical layer specification 8 6.2 Specifications 11 6.3 Basic DiSEqC functionality 11 6.3.1 Set SSPA Power Level command 0xC8 12 6.3.2 Internal Reference mode Enable (0xDD) 12 7 BUC DC supply voltage 13 8 Reference documents 13 06 January 2005 2

Foreword The SatLabs Group is an international, not-for-profit association whose members are committed to bringing the deployment of the DVB-RCS standard to large-scale adoption. SatLabs membership is formed by service providers, satellite operators, system integrators, terminal manufacturers and technology providers with an interest in DVB-RCS. The mission of SatLabs is to complement the DVB-RCS standard with recommendations and guidelines to facilitate DVB-RCS terminal interoperability, and to provide a mechanism for formal DVB-RCS interoperability certification. While the Inter-Facility Link (IFL) is not actually part of the DVB-RCS Specification itself, different options for the IFL are described in detail in the DVB-RCS Guidelines. This Recommendation builds on that work and from experience gained by many SatLabs members, in order to agree a baseline specification for the IFL. This will open the way for interoperability between Indoor units and Outdoor units from different manufacturers. 06 January 2005 3

Common IFL Specification for DVB-RCS terminals 1 Introduction This document describes the latest version of the ESA Satlabs WG#1 agreed target specification of the Common IFL physical interface definition of DVB-RCS terminals. In the Common IFL specification consist of a detailed description of the inter-facility link interface between DVB-RCS modem and outdoor unit. In this version both internal- as well as external ODU local oscillator frequency reference systems are covered. The required Local Oscillator reference system can be selected by DiSEqC command. 2 RX IF specification The RX IF system interfaces between LNB and modem. The definition is directly derived from the ETS 300 784, EN61319-1 and DVB doc A01 rev.1 for "Universal" DBS/DTH terminals. Parameter Value Unit Note 2.1 Frequency scheme no spectral inversion 2.1.1 RF input range, low band See table below 2.1.2 IF output range, low band 950 1950 MHz 2.1.3 RF input range, high band See table below 2.1.4 IF output range, high band 1100 2150 MHz 2.2 IF Impedance 75 Ohm 2.3 Return loss LNB & modem > 8 db 2.4 Connector type F-type 2.5 Connector & cable color code blue 2.6 Cable loss @ 2150 MHz < 40 db/100m 2.7 LNB band switch tone command acc. EN 61319-1 2.7.1 Low band selected 0.0 0.2 Vpp 2.7.2 High band selected 0.4 0.8 Vpp 18 26 khz 06 January 2005 4

2.8 Polarization fixed linear, orthogonal with TX 1 2.9 DC supply voltage 11-19 V on the LNB 2.10 DC supply current < 300 ma Typical RF Input Ranges include: Band RF [GHz] LO [GHz] IF [MHz] C-Band 3.7-4.2 5.15 950 1450 Ku-band - Low band 10.7 11.7 9.75 950-1950 Ku-band High band 11.7-12.75 10.6 1100 2150 Ka-band 19.7 20.2 18.75 950 1450 3 TX IFL functionality The TX IFL system interfaces between modem and BUC. A single coaxial cable carries: The TX IF signal in L-band The TX LO frequency reference signal. A low frequency sub-carrier for DiSEqC signaling The DC power supplying the BUC 4 TX IFL specification 4.1 IF frequency scheme In general L-band is recommended for all RCS terminals according to following scheme, with no spectral inversion, according: 1 If dual-polarisation reception is supported then the voltage (13/17V) switching command as specified in EN61319-1 shall be used. 06 January 2005 5

Band RF [GHz] LO [GHz] IF [MHz] Ku-band 14.00 14.50 13.05 950 1450 Extended Ku-band 13.75 14.25 12.80 950 1450 Full extended Ku-band 13.75 14.50 12.80 950 1700 Ka-band 29.50 30.00 28.55 950 1450 4.2 IFL system specification Recommended is a fixed cable loss IFL system for constant gain BUCs. This common system uses a fixed set IF drive level at modem output, as well as fixed cable attenuation and constant BUC gain. The IFL cable loss and slope are compensated at installation of the terminal by setting-up standard level values in the modem. Condition that cable loss and slope as well as the BU C gain are well known and do not change over operational conditions or life-time of the terminal. Parameter Value Unit Note set once during 4.2.1 IF drive level modem installation 4.2.2 IF impedance 75 Ohm 4.2.3 Return loss BUC & modem > 13 db 4.2.4 Return loss cable > 16 db 4.2.5 Connector type F-type 4.2.6 Connector & Cable color code Red 4.2.7 Cable attenuation @ 1700 MHz < 30 db/100m 4.2.8 Cable attenuation uniformity < 0.3 db/mhz 4.2.9 Cable length < 50 m 5 BUC LO frequency reference system The LO reference system can be selected by the modem using a DiSEqC command string [see chapter 6]. The default system setting is to external reference mode. 06 January 2005 6

Internal mode can be selected by the transmission of the enable int ref DiSEqC command. This mode shall be cleared either by a full reset command or power down. Note: Absence of 10 MHz does not change mode (absence of 10 MHz in ext mode may be used to set alarm state and deactivate SSPA) 5.1 Internal Reference system specification In the internal LO reference system, a 10 MHz reference signal is derived from the BUC PLO and send back to the modem to enable frequency correction of the TX-IF signal. Parameter Value Unit Note 5.1.1 Reference type frequency synchronous 5.1.2 Frequency 10 MHz sinusoidal 5.1.3 Frequency tolerance < +/- 30 ppm overall* 5.1.4 Level -5 +/- 5 dbm 5.1.5 Level on PLO un-lock alarm < -30 dbm Optional 5.1.5 Spurious level < 30 dbc 0.01 20 MHz * Note: The frequency tolerance includes set up error, temperature drift and 10 years ageing. 5.2 External Reference system specification In the external LO reference system, at forward link NCR derived 10 MHz reference signal is send from modem to synchronize the BUC PLO. Parameter Value Unit Note 5.2.1 Reference type frequency synchronous 5.2.2 Frequency 10 MHz sinusoidal 5.2.3 Frequency tolerance < +/- 25 ppm overall* 06 January 2005 7

5.2.4 Level 0 +/- 5 dbm 5.2.5 Spurious level < 30 dbc 0.01 20 MHz 5.2.6 Phase Noise: 10 Hz -86 dbc/hz 100 Hz -124 dbc/hz 1 khz -134 dbc/hz 10 khz -144 dbc/hz 100 khz -152 dbc/hz Figures derived from TR101790 * Note: The reference signal is derived from the NCR of the forward link, therefore is highly accurate. 6 BUC DiSEqC signaling DiSEqC IFL signaling between modem and BUC enables a number of advanced applications and features. The DVB-RCS Guidelines, TR101790 suggest the use of either 22 khz AM on/off modulation or 10.7 MHz FSK. SatLabs proposes for 22 khz AM. 6.1 Physical layer specification The signaling commands from modem to radio will be make use of on/off voltage modulation as suggested in the Guidelines TR101 790. Parameter Value Unit Note 6.1.1 Carrier frequency 22 +/- 4 khz acc. EN 61319-1 6.1.2 Modulation type on/off using voltage superimposing 6.1.3 Carrier level, logical 0/1 0 / 0.6 Vpp The low data rate communication between the IDU and the ODU is based on a 22 khz PWK signal as used by DiSEqC [22]. The impedance of the bus at 22 khz shall be 15 Ω. A parallel inductor of 270 µh can be used to support a DC. power supply current. In this case a capacitor to ground should be supplied to shape the 22 khz signal. The DC feeding point is grounded for 22 khz with a capacitor. If a DC is not needed for powering peripheral devices, then in order to 06 January 2005 8

maintain correct operation of the DiSEqC bus, there should be a minimum of 10 V bias applied, but the inductor and capacitor can be omitted. The control signal from every device on the bus is produced by a 43 ma current shunt producing a 650 mv signal which is monitored by every device. This amplitude of the DiSEqC carrier tone on the bus is normally too small to detect directly on a "TTL" or "CMOS" compatible pin on a microcontroller, so usually a "comparator" input, or a simple external (one-transistor) amplifier, is required. In any case, it is important not to make the input too sensitive to smallamplitude signals which may be "noise" or interference. It is recommended that the smallest amplitude normally detected is about 200 mv peak-peak. This can be achieved either with hysteresis (positive feedback applied around the comparator/amplifier) or with a DC bias offset (equivalent to about 100 mv) applied to the input of the amplifier/comparator. Hysteresis (if symmetrical) can maintain a reasonably constant 50 % duty cycle for the detected carrier tone, whilst the DC offset method may generate a less desirable asymmetric (pulse) waveform when the carrier amplitude approaches the lower limit. All devices are connected in parallel on the bus and shall therefore have high impedance. 06 January 2005 9

Figure 6-1 22 khz PWK bus concept 43 ma R B = 15 Ω Bias Voltage > 10 V > 10 000 Ω C r L B = 270 µh U 22 khz R r C B = 470 nf typically ODU 43 ma > 10 000 Ω C r U 22 khz R r IDU 1 43 ma > 10 000 Ω C r U 22 khz R r IDU n 06 January 2005 10

6.2 Specifications Parameter Value Unit Note 6.2.1 Carrier frequency 22 khz ± 20 % 6.2.2 Bus load impedance R B 15 Ω ± 5 % DC supply 6.2.3 Bus load inductance L B 270 µh ± 5 % 6.2.4 Bus load capacitance C B 470 nf typical Current source 6.2.5 current amplitude 43 ma ± 10 % 6.2.6 source impedance > 10 kω 6.2.7 22 khz carrier detection device resistance R r 5 to 10 kω typical 6.2.8 DC block capacitor typically a few nf, but depends on the value R r, it should be chosen so as to give a time constant of around 100 µs Bit definition 6.2.9 timing base 0.5 ms ± 0,1 6.2.10 bit length 1.5 ms 6.2.11 "0" 1,0 ms burst + 0,5 ms pause 6.2.12 "1" 0,5 ms burst + 1,0 ms pause 6.3 Basic DiSEqC functionality This two-way system supports should support the DiSEqC commands set as described in the DVB-RCS Guidelines, TR 101 790. As a minimum the system must support the following subset of command messages. Hex byte Command Description Note 00 Reset Reset all ODU functions 0A Soft reset ODU soft reset 12 Monitoring ODU status request C6 SSPA on Enable SSPA C7 SSPA off Disable SSPA ETSI mandatory 06 January 2005 11

C8 Set SSPA Power level Enable Constant Power mode and set level See below CE TX off Disable TX power save CF TX on Enable TX DD 2 Int Ref on Enable int. freq. ref. mode Default off See description below 6.3.1 Set SSPA Power Level command 0xC8 Default mode is off; IDU does not send command automatically. IDU should allow via both the local or air interfaces the command to be enabled (on), in which case the 0xC8 command with data value 00 is sent immediately. If positive reply received from ODU then Constant Power mode is enabled and message E2 82 C8 00 is sent each time on boot-up. If a negative reply is received, IDU remains in default mode, error message generated. Once enabled, any values for level (+/-128) may be set via both local and air interfaces. Constant Power mode shall be cleared by full reset command or at power down. For ODUs that do not support constant power mode they send NACK E5 request not supported. For ODUs that support constant power mode (they must also support constant gain) they will switch to CP mode after receiving message E2 82 C8 00 and reply with ACK E4 command accepted. Thereafter the IDU may set SSPA level by instructions received via both the local or air interfaces as described above. 6.3.2 Internal Reference mode Enable (0xDD) This command allows the IDU to enable the Internal Reference Mode in the ODU. This mode shall be cleared by either a full reset 00 or on power down. 2 Next available reserved command after proposed modifications to TR101790v1.2.1 for mobile antenna submitted to DVB TM doc: TM-RCS0560 EUTELSAT to confirm 06 January 2005 12

Direction Message Comment IDU ODU E2 82 DD IDU sends the transmitter enable command to the ODU ODU IDU E5 Request rejected, not supported by ODU (optional feature) ODU IDU E6 Request rejected, parity error during transmission ODU IDU E7 Request rejected, message format not recognized ODU IDU E4 Command accepted. ODU shall power on transmitter 7 BUC DC supply voltage Parameter value unit note 7.1 DC voltage @ BUC 18-30 V 24 V typical 7.2 Supply current < 2 A @ 24 V after inrush 8 Reference documents 1. ETSI EN 301 790 DVB-RCS Specification 2. ETSI TR 101 790 DVB-RCS Guidelines 3. ETSI EN 301 428 Ku-band VSAT requirements 4. ETSI EN 301 459 Ka-band VSAT requirements 5. EUTELSAT DVB-RCST ODU Recommendations; issue 1.1 6. ETSI EN 300 784 DBS/DTH terminal requirements 7. CENELEC EN 61319-1 Universal DBS/DTH terminal requirements 8. SATLABS SL_115_v10 Common IFL Specification of DVB-RCS terminals 06 January 2005 13