Bulletin 190 Compact. Combination Starters

Similar documents
Your order must include: cat. no. of the miniature contactor specified with coil voltage code and, if required, cat. no. of any accessories

Bulletin 100-G IEC Contactors

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

Bulletin 100-G IEC Contactors

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

Bulletin 190 IEC Modular Starter System

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Series CDP2 Definite Purpose Contactors

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Series CDP2 Definite Purpose Contactors

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Contactors and Contactor Assemblies

Bulletin 700-FE, -FS, -M, -CF, CRF, -HA, -HC, -HK, -HL Relays and Timers Quick Selection Table

Features XT SC 012 B B A

AS09..S 3-pole Contactors - Spring Terminals

Bulletin 305 AC Starters

Features XT SC 012 B B A

XT IEC Power Control Combination Motor Controllers

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

Selection guide siemens.com/sirius-modular-system

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Series CT7N Bimetallic Overload Relays

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

llen-bradley 194R-HM4-NFPA3

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

3-pole contactors for standard applications

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

High performance circuit breakers

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

TeSys circuit-breakers

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Bulletin 509 Full Voltage

59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview.

10 PDUs 19 PDUs Zero-U PDUs

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

AC1036. Definite Purpose Contactors

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Magnecraft Power Relays

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) XT RE C 10 B 22 AD

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Interface Relays and Optocouplers Product group picture

Bulletin 500 Top Wiring For Motor Loads

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Minicontactorrelay,2NO/2NC,DCoperated

Accessories Order No. Page Individual parts Order No. Page K1 1) K3 2) K2 2) 14 Auxiliary switch block, front. 3/105 terminals.

Bulletin 150, 154 Softstarters Quick Selection Table

Manual Motor Starter Specifcations

AC diagonal module Ø 200 mm


Definite Purpose Contactors

ALLEN BRADLEY TIMING RELAY

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

16 A and 25 A power contactors with or without handle

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

A V 50Hz / V 60Hz

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Kinetix Application Note

DMX and 4000 air circuit breakers from 800 to 4000 A

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Ordering details. Approval. Classification

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Magnetic and Hydraulic-Magnetic Circuit Breaker

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Pluggable interface relays CR-M Miniature relays

Power Circuit of a UL508A Panel. Typical UL489 Application

Data Sheet Definite Purpose Contactors Ex9CK Series

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

XT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line...

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

VAT 20 Adjustable Frequency Drive

YLAA YLAA0175 AIR-COOLED SCROLL CHILLERS STYLE A, B or C (60 Hz) TON KW

Transcription:

0Circuit reaker ulletin 10 ulletin 10 Compact Combination Starters Power Range 0.1...45 ulletin 10E Modular Eco Starters ulletin 10S Pre-wired Compact Starters Uses ulletin 140M Motor Protectors and ulletin 100-C Contactors 140M is UL/CS pproved as Self-Protected (Type E) Manual Combination Starters Type 2 Coordination with 100-C Contactors Mounts to DIN Rail(s) or Screw Mounts TLE OF CONTENTS Description Page Description Page Product Selection..................................... 46 ccessories.......................................... 4 Specifications Factory Options..................................... 4 Wiring Diagrams...................................... 51 pproximate Dimensions............................... 52 Type 2 Coordination................................... 5 Conformity to Standards: IEC 47-1/2/4 IEC 204-1 pprovals: CE Your order must include: Cat. No. of the motor protector selected. If required, Cat. No. of any accessories. 45

ulletin 10E Product Selection 10E Modular Eco Starter using 140M Motor Protector and 100M Mini Contactor Mounting Options: - Snap Fixing on (1) 35 mm DIN Rail C or DC Control Coils Thermal Trip [] Magnetic Trip Typical 3-phase [HP] Non-Reversing Starter ➊ [] I cu 200V 230V 460V 575V Cat. No. Uses 140M-C, High reak 0.10...0.16 2.1 65 10E-MN 2-C16X 0.16...0.25 3.3 65 10E-MN 2-C25X 0.25...0.40 5.2 65 10E-MN 2-C40X 0.40...0.63 8.2 65 10E-MN 2-C63X 0.63...1.00 13 65 0.5 0.75 10E-MN 2-C10X 1.00...1.60 21 65 1 1 10E-MN 2-C16X 1.60...2.50 33 65 0.5 0.5 1.5 2 10E-MN 2-C25X 2.50...4.00 52 65 1 1 3 3 10E-MN 2-C40X 4.00...6.30 82 65 1.5 2 3 5 10E-NN 2-C63X 6.30...10.0 130 65 3 3 5 5 10E-NN 2-CC10X ➊ 1 N.O. auxiliary contact on contactor is standard. See Factory Options on p. 4 for additional auxiliary contact configurations. Standard Voltage Suffix Codes for DC Control Voltage 24V 48V 100V 100 120V 220 230V 230 240V 380V 50 Hz KD KH D KK 60 Hz KD KH D KK DC 24 Factory Installed Options Page 4 140M ccessories Page 21 100M ccessories Publication No. 0100C-1.0.1 46

ulletin 10E Product Selection, Continued 10E Modular Eco Starter using 140M Motor Protector and 100C MCS Contactor Mounting Options: - Snap Fixing on (1) 35 mm DIN Rail C Control Coils Thermal Trip [] Magnetic Trip [] ➊ 1 N.O. auxiliary contact on contactor is standard. See Factory Options on p. 4 for additional auxiliary contact configurations. Standard Voltage Suffix Codes for C Control I cu Typical 3-phase [HP] 200V 230V 460V 575V Uses 140M-C, High reak Non-Reversing Starter ➊ Cat. No. 0.10...0.16 2.1 65 10E-N 2-C16X 0.16...0.25 3.3 65 10E-N 2-C25X 0.25...0.40 5.2 65 10E-N 2-C40X 0.40...0.63 8.2 65 10E-N 2-C63X 0.63...1.00 13 65 0.5 0.75 10E-N 2-C10X 1.00...1.60 21 65 1 1 10E-N 2-C16X 1.60...2.50 33 65 0.5 0.5 1.5 2 10E-N 2-C25X 2.50...4.00 52 65 1 1 3 3 10E-N 2-C40X 4.00...6.30 82 65 1.5 2 3 5 10E-N 2-C63X 6.30...10.0 130 65 2 3 7.5 10 10E-N 2-CC10X 10.0 16.0 208 10 3 5 10 10 10E-CN 2-CC16X 14.5 20.0 260 10 5 7.5 15 15 10E-DN 2-CC20X 18.5 25.0 325 10 5 7.5 15 15 10E-DN 2-CC25X Uses 140M-D, High reak PLUS 1.60 2.50 33 65 0.5 0.5 1.5 2 10E-N 2-D25X 2.50 4.00 52 65 1 1 3 3 10E-N 2-D40X 4.00 6.30 82 65 1.5 2 3 5 10E-N 2-D63X 6.30 10.0 130 65 2 3 7.5 10 10E-N 2-DC10X 10.0 16.0 208 65 3 5 10 10 10E-CN 2-DC16X 14.5 20.0 260 65 5 7.5 15 15 10E-DN 2-DD20X 18.5 25.0 325 25 5 7.5 15 15 10E-DN 2-DD25X Type 10E [V] 12 24 32 36 42 48 100 100 110 110 120 127 200 200 220 200 230 208 50 Hz R K V W X Y KP D P S KG 60 Hz Q J V X KP D KG H L 50/60 Hz KJ KY KP KD KG KL [V] 220 230 230 230 240 240 277 347 380 380... 400 400 400 415 440 480 500 550 600 50 Hz F V T N G M C 60 Hz T I E N C 50/60 Hz KF K KN K 208 240 Factory Installed Options Page 4 140M ccessories Page 21 100M ccessories Publication No. 0100C-1.0.1 47

ulletin 10S Product Selection, Continued 10S Compact Combination Starter using 140M Motor Protector and 100-C Contactor uxiliary Contacts Wired to Terminal lock at ottom of Starter ssembly Mounting Options: - Screw Fixing - Snap Fixing on (1) or (2) 35 mm DIN Rails - Snap Fixing on (1) 75 mm DIN Rail C or DC Control Coils ➊ Thermal Trip [] Magnetic Trip Typical 3-phase [HP] Non-Reversing Starter ➊ [] I cu 200V 230V 460V 575V Cat. No. 1 N.O. + 1 N.C. auxiliary contacts on 140M is standard. 1 N.O. auxiliary contact on 100C contactor is standard. See Factory Options on p. 50 for additional auxiliary contact configurations. Standard Voltage Suffix Codes for C Control 10S Standard Voltage Suffix Codes for DC Control 10S Uses 140M-C, High reak 0.10...0.16 2.1 65 10S-N 2-C16C 0.16...0.25 3.3 65 10S-N 2-C25C 0.25...0.40 5.2 65 10S-N 2-C40C 0.40...0.63 8.2 65 10S-N 2-C63C 0.63...1.00 13 65 0.5 0.75 10S-N 2-C10C 1.00...1.60 21 65 1 1 10S-N 2-C16C 1.60...2.50 33 65 0.5 0.5 1.5 2 10S-N 2-C25C 2.50...4.00 52 65 1 1 3 3 10S-N 2-C40C 4.00...6.30 82 65 1.5 2 3 5 10S-N 2-C63C 6.30...10.0 130 65 2 3 7.5 10 10S-N 2-CC10C 10.0...16.0 208 10 3 5 10 10 10S-CN 2-CC16C 14.5...20.0 260 10 5 7.5 15 15 10S-DN 2-CC20C 18.5...25.0 325 10 5 7.5 15 15 10S-DN 2-CC25C Uses 140M-D, High reak PLUS 1.60...2.50 33 65 0.5 0.5 1.5 2 10S-N 2-D25C 2.50...4.00 52 65 1 1 3 3 10S-N 2-D40C 4.00...6.30 82 65 1.5 2 3 5 10S-N 2-D63C 6.30...10.0 130 65 2 3 7.5 10 10S-N 2-DC10C 10.0...16.0 208 65 3 5 10 10 10S-CN 2-DC16C 14.5...20.0 260 65 5 7.5 15 15 10S-DN 2-DC20C 18.5...25.0 325 25 5 7.5 15 15 10S-DN 2-DC25C [V] 100-200- 200-208- 12 24 32 36 42 48 100 110 110 120 127 200 220 230 208 240 50 Hz R K V W X Y KP D P S KG 60 Hz Q J V X KP D KG H L 50/60 Hz KJ KY KP KD KG KL [V] 220-230 230 230-240 240 277 347 380 380-400 400 400-415 440 480 500 550 600 50 Hz F V T N G M C 60 Hz T I E N C 50/60 Hz KF K KN K Voltage [V] 6 12 12 24 24 w/ diode 36 48 60 64 72 80 110 115 125 220 230 240 Code ZR ZQ ZJ DJ ZW ZY ZZ Z ZG ZE ZD ZP ZS Z ZF ZT Factory Installed Options Page 50 140M ccessories Page 21 100M ccessories Publication No. 0100C-1.0.1 48

ulletin 10 Specifications 10E Factory Options: For modifications add (option code ➊) and (option code ➋) for desired features to catalog number. ➊ Replace option code X with desired auxiliary contact: 10E-MND2-C16X 140M uxiliary and Trip Contacts X C D R S Without uxiliary and Trip Contacts (STNDRD) uxiliary Contact 1 N.C. uxiliary Contact 1 N.C. uxiliary Contact 1 N.O. + 1 N.C. uxiliary Contact 2 N.O. 1 N.O. Trip + 1 N.C. uxiliary Contact 1 N.O. Trip + 1 N.O. uxiliary Contact ➋ dd desired option codes FTER auxiliary contact option code: 10E-MND2-C-16X-Y Modifications, ccessories JE Electronic Interfaces (100-C) R Surge Suppressor RC (100-C) V Surge Suppressor Varistor (100-C) D Surge Suppressor Diode (100-C) KN Lockable Twist Knob (140M) - lack KY Lockable Twist Knob (140M) - Red/Yellow dditional Contactor uxiliaries (Side Mount) S01 1 N.C. S10 1 N.O. S11 1 N.O. + 1 N.C. S20 2 N.O. dditional Contactor uxiliaries (Front Mount) F11 1 N.O. + 1 N.C. F20 2 N.O. F22 2 N.O. + 2 N.C. dditional 140M uxiliaries (Side Mount) 02 2 N.C. 20 2 N.O. 11 1 N.O. + 1 N.C. dditional 140M Trip Contacts (Side Mount) R00 1 N.O. Thermal-Mag + 1 N.O. Mag Only R01 1 N.O. Thermal-Mag + 1 N.C. Mag Only R10 1 N.C. Thermal-Mag + 1 N.O. Mag Only M11 1 N.O. Mag Only + 1 N.C. Mag Only 4

ulletin 10 Specifications, Continued 10S Factory Options: For modifications add (option code ➊) and (option code ➋) for desired features to catalog number. ➊ Replace option code C with desired auxiliary contact: 10S-ND2-C16C C D R S 140M uxiliary and Trip Contacts uxiliary Contact 1 N.O. + 1 N.C. (STNDRD) uxiliary Contact 2 N.O. 1 N.O. Trip + 1 N.C. uxiliary Contact 1 N.O. Trip + 1 N.O. uxiliary Contact ➋ dd desired option codes FTER auxiliary contact option code: 10S-ND2-C16C-Y Modifications, ccessories JE Electronic Interfaces (100-C) R Surge Suppressor RC (100-C) V Surge Suppressor Varistor (100-C) D Surge Suppressor Diode (100-C) SP Socket and Plug for Control Circuit KN Lockable Twist Knob (140M) - lack KY Lockable Twist Knob (140M) - Red/Yellow dditional Contactor uxiliaries (Side Mount) S01 1 N.C. S10 1 N.O. S11 1 N.O. + 1 N.C. S20 2 N.O. dditional 140M uxiliaries (Side Mount) 02 2 N.C. 20 2 N.O. 11 1 N.O. + 1 N.C. dditional 140M Trip Contacts (Side Mount) R00 1 N.O. Thermal-Mag + 1 N.O. Mag Only R01 1 N.O. Thermal-Mag + 1 N.C. Mag Only R10 1 N.C. Thermal-Mag + 1 N.O. Mag Only M11 1 N.O. Mag Only + 1 N.C. Mag Only 50

ulletin 10 Wiring Diagrams Wiring Diagram 10S- D 10S-...D L1 L2 L3 10S-...D L1 L2 L3 1 3 5 2 4 6 Trip Contact 1 3 5 2 4 6 With Electronic Interface JE N1 + - K1M 1 3 5 2 4 6 1 2 K1M 1 3 5 2 4 6 1 2 1 2 1 T1 T2 T3 2 1 T1 T2 T3 2 1 2 E1 E2 1 13 14 21 22 13 14 13 14 27 28 13 14 - JE Option 23 24 21 22 21 22 10S- _ 2- C 10S- _ 2- S Wiring Diagram 10S-E G 10S-E...G L1 L2 L3 10S-E...G L1 L2 L3 Q 13 14 21 22 1 3 5 2 4 6 Q 13 14 27 28 Trip Contact 1 3 5 2 4 6 With Electronic Interface JE N1 13 14 21 K1M 22 1 3 5 2 4 6 1 2 13 14 21 K1M 22 1 3 5 2 4 6 1 2 1 2 + - 1 14 14 T1 T2 T3 2 1 14 14 T1 T2 T3 2 1 2 E1 E2 1 13 14 21 22 13 21 13 14 27 28 13 21 23 24 23 24 23 24 - JE Option 24 24 23 24 23 23 10S- _ 2- C 10S- _ 2- S 51

ulletin 10 pproximate Dimensions Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes. 10E pproximate Dimensions c1 3 (3/32) b2 b b2 b b1 b1 a a a1 a c Cat. No. a a1 b b1 b2 c c1 10E Eco Starters 10E-MN 10E-NN 164 (6-15/32) 45 (1-25/32) 45 (1-25/32) 0 45 (1-25/32) 10E-N 10E-DN 178 (7) 83.5 (3-1/64) 70 (2-4/64) 11E Reversing Eco Starters 11E-MN 11E-NN 164 (6-15/32) 45 (1-25/32) 45 (1-25/32) 0 45 (1-25/32) 11E-N 11E-DN 178 (7) 83.5 (3-1/64) 70 (2-4/64) 52

pproximate Dimensions, Continued ulletin 10 Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes. 140M + 100-C/104-C pproximate Dimensions Separate Mount c1 3 (3/32) b2 b b2 b b1 b1 a a a1 a c 140M + 100-C 140M + 104-C Cat. No. a a1 b b1 b2 c c1 140M-C2 OR 140M-D8 + 100C (must be separately mounted on 2 DIN Rails) 100-C0ZU 100-C16ZU 45 (1-25/32) 0 178 (7) 45 (1-25/32) 10 (4-1/64) 100-C23ZU 127 (5) 70 (2-4/64) 140M-C2 OR 140M-D8 + 104C (must be separately mounted on 2 DIN Rails) 100-C0ZU 100-C16ZU 10 (4-1/64) 45 (1-25/32) 10 (25/64) 178 (7) 45 (1-25/32) 100-C23ZU 127 (5) 70 (2-4/64) 140M-F8 + 100-C Contactors (must be separately mounted on 2 DIN Rails) 100-C30 100-C37 101 (4) 45 (1-25/32) 0 164 (6-15/32) 55 (2-11/64) 105 (4-/64) 100-C30Z 100-C37Z 145 (5-45/64) 110 (4-21/64) 100-C43 104 (4-1/8) 54 (2-1/8) 0 178 (7) 55 (2-11/64) 105 (4-/64) 100-C43Z 148 (5-13/16) 110 (4-21/64) 140M-F8 + 104-C Reversing Contactors (must be separately mounted on 2 DIN Rails) 100-C30 100-C37 101 (4) 45 (1-25/32) 10 (25/64) 164 (6-15/32) 55 (2-11/64) 105 (4-/64) 100-C30Z 100-C37Z 145 (5-45/64) 110 (4-21/64) 100-C43 104 (4-1/8) 54 (2-1/8) 10 (25/64) 178 (7) 55 (2-11/64) 105 (4-/64) 100-C43Z 148 (5-13/16) 110 (4-21/64) 53

ulletin 10 pproximate Dimensions, Continued Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes. 10S- D pproximate Dimensions 5.5 45 Ø5.4 4 8 18 215 178 Ø5.4 34 5.5 5.5 C 10S-N 10S-N 140M-C 112 10S-CN 10S-DN 140M-D 122 10S-NZ 10S-NZ 140M-C 134.5 10S-CNZ 140M-D 144.5 10S-DNZ 140M-C 157 140M-D 167 107 100-F, 100-FC 100-FPT 100-FL C 138 157 160 132.5 100-F, 100-FC 163.5 150 100-F, 100-FC 181 54

Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes. 10S- D pproximate Dimensions ulletin 10 pproximate Dimensions, Continued ;; ;; 25 Safety Clearance 25 25 0 0 115 3.5 11 21 35 35 101.5 46.2 125±1 7.5 ;y 135 15 75 25 55

ulletin 10 pproximate Dimensions, Continued Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes. 10S-E and 10S-F pproximate Dimensions 5.5 54 Ø5.4 4 8 18 238 200 Ø5.4 43 5.5 5.5 C 10S-EN 10S-FN 10S-ENZ 10S-FNZ 140M-F 135 124 100-F 100-FPT 100-FL C 154.5 173.5 176.5 17 168 100-F 18.5 56

pproximate Dimensions, Continued ulletin 10 Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes. 10S-G pproximate Dimensions 5.5 54 Ø5.4 4 8 18 238 200 Ø5.4 43 5.5 5.5 C C 10S-GN 140M-F 135 118.5 100-F 100-FPT 100-FL 157 176 17 10S-GNZ 17 162.5 100-F 201 57

ulletin 10 pproximate Dimensions, Continued Dimensions are shown in millimeters. Dimensions are not intended for manufacturing purposes. 10-E G pproximate Dimensions Safety Clearance 25 25 25 0 0 0 25 C DC 3.5 21 56 7.5 125±1;y 75 35 145.5 25 58

Type 2 Coordination ulletin 10E Type 2 Coordination per UL 508E 10E Modular Eco Starter using 140M Motor Protector and 100M Mini Contactors or 100-C MCS Contactors Voltage: 480V, 60 HZ Eco Starter Cat. No. Thermal Overload Release Setting Range [] Magnetic Release Response Current [] Short-Circuit Current, I q [k] 10E-MN 2-C16X 0.10...0.16 2.1 65 10E-MN 2-C25X 0.16...0.25 3.3 65 10E-MN 2-C40X 0.25...0.40 5.2 65 10E-MN 2-C63X 0.40...0.63 8.2 65 10E-MN 2-C10X 0.63...1.0 13 65 10E-MN 2-C16X 1.0...1.6 21 65 10E-N 2-C16X 0.10...0.16 2.1 65 10E-N 2-C25X 0.16...0.25 3.3 65 10E-N 2-C40X 0.25...0.40 5.2 65 10E-N 2-C63X 0.40...0.63 8.2 65 10E-N 2-C10X 0.63...1.0 13 65 10E-N 2-C16X 1.0...1.6 21 65 10E-N 2-C25X 1.6 2.5 33 50 10E-N 2-D25X 1.6 2.5 33 65 10E-N 2-D40X 2.5...4.0 52 65 10E-N 2-D63X 4.0...6.3 82 65 10E-N 2-DC10X 6.3...10.0 130 65 10E-CN 2-DC16X 10.0...16.0 201 65 10E-DN 2-DC20X 14.5...20.0 260 65 10E-DN 2-DC25X 18.0...25.0 325 50 Voltage: 600V, 60 HZ Eco Starter Cat. No. Thermal Overload Release Setting Range [] Magnetic Release Response Current [] Short-Circuit Current, I q [k] 10E-MN 2-C16X 0.10...0.16 2.1 47 10E-MN 2-C25X 0.16...0.25 3.3 47 10E-MN 2-C40X 0.25...0.40 5.2 47 10E-MN 2-C63X 0.40...0.63 8.2 47 10E-MN 2-C10X 0.63...1.0 13 47 10E-MN 2-C16X 1.0...1.6 21 47 10E-N 2-C16X 0.10...0.16 2.1 47 10E-N 2-C25X 0.16...0.25 3.3 47 10E-N 2-C40X 0.25 0.40 5.2 47 10E-N 2-C63X 0.40 0.63 8.2 47 10E-N 2-C10X 0.63 1.0 13 47 10E-N 2-C16X 1.0 1.6 21 47 10E-N 2-C25X 1.6 2.5 33 10 10E-N 2-D25C 1.6 2.5 33 10 Definition of Type "2" short-circuit coordination per UL 508E: The contactor or starter must not endanger persons or plant in the event of a short-circuit. No damage to the overload relay or other parts may occur with the exception of welding of the contactor or starter contacts if t hese can be easily separated without appreciable deformation (such as with a screwdriver). In the event of short-circuit, fast-opening, strong current-limiting ulletin 140M motor protectors make it possible to build economical, fully shortcircuit coordinated starter combinations in accordance with UL 508E, Type "2" coordination. 5

ulletin 10S Type 2 Coordination Type 2 Coordination per UL 508E 10S Compact Combination Starter using 140M Motor Protector and 100-C Contactor Voltage: 480V, 60 HZ Compact Starter Cat. No. Thermal Overload Release Setting Range [] Magnetic Release Response Current [] Short-Circuit Current, I q [k] 10S-N 2-C16C 0.10...0.16 2.1 65 10S-N 2-C25C 0.16...0.25 3.3 65 10S-N 2-C40C 0.25...0.40 5.2 65 10S-N 2-C63C 0.40...0.63 8.2 65 10S-N 2-C10C 0.63...1.0 13 65 10S-N 2-C16C 1.0...1.6 21 65 10S-N 2-C25C 1.6 2.5 33 65 10S-N 2-D25C 1.6 2.5 33 65 10S-N 2-D40C 2.5 4.0 52 65 10S-N 2-D63C 4.0 6.3 82 65 10S-N 2-DC10C 6.3 10.0 130 65 10S-CN 2-DC16C 10.0 16.0 208 65 10S-DN 2-DC20C 14.5 20.0 260 65 10S-DN 2-DC25C 18.0 25.0 325 50 Voltage: 600V, 60 HZ Compact Starter Cat. No. Thermal Overload Release Setting Range [] Magnetic Release Response Current [] Short-Circuit Current, I q [k] 10S-N 2-C16C 0.10...0.16 2.1 47 10S-N 2-C25C 0.16...0.25 3.3 47 10S-N 2-C40C 0.25...0.40 5.2 47 10S-N 2-C63C 0.40...0.63 8.2 47 10S-N 2-C10C 0.63...1.0 13 47 10S-N 2-C16C 1.0...1.6 21 47 10S-N 2-C25C 1.6 2.5 33 10 10S-N 2-D25C 1.6 2.5 33 10 Definition of Type "2" short-circuit coordination per UL 508E: The contactor or starter must not endanger persons or plant in the event of a short-circuit. No damage to the overload relay or other parts may occur with the exception of welding of the contactor or starter contacts if t hese can be easily separated without appreciable deformation (such as with a screwdriver). In the event of short-circuit, fast-opening, strong current-limiting ulletin 140M motor protectors make it possible to build economical, fully shortcircuit coordinated starter combinations in accordance with UL 508E, Type "2" coordination. 60

Publication 140M-SG001-US-P January 2000 1 Rockwell International Corporation. ll rights reserved. Printed in US.