The GTP-32 Control Processor helps you solve equipment interface, control and monitoring problems, quickly and easily

Similar documents
DX-10 tm Digital Interface User s Guide

(((((((((<<<<<<<<<<<<<<<<<<<<Q

Kaleido-IP HDMI Baseband multiviewer

specifications of your design. Generally, this component will be customized to meet the specific look of the broadcaster.

VNP 100 application note: At home Production Workflow, REMI

ELC-MVS01 Multi-format Control Room Automation Software

BROADCAST PRODUCTION\MASTER CONTROL SWITCHERS

C8000. switch over & ducking

33 Really Good Reasons To Choose A Ross Carbonite

MVS-3000A. Compact and flexible SD / HD video switcher. Overview. The compact MVS-3000A brings top-end performance to a mid-range switcher

Model No. ST60-SPS (-SRN, -SRK, -DRN, -DRK)

PRODUCT BROCHURE. Gemini Matrix Intercom System. Mentor RG + MasterMind Sync and Test Pulse Generator

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit

National Park Service Photo MC-4000 Master Control Processor

Model No. ST200-S. Universal VTR/DDR. Controller USER MANUAL 1 ST200-S. Manual Version Document No... ST200-S_User_Manual

Model No. ST100 VTR CONTROLLER

NV5100MC. Multi-channel, HD/SD master control switching and branding system. Master control switching and channel branding

Model No. ST60-S (-SRN, -SRK, -DRN, -DRK)

HVS-5000 Series. Video Switchers & DSKs. 3G/HD/SD 2M/E - 4M/E Digital Video Switcher

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

PRODUCT BROCHURE. Broadcast Solutions. Gemini Matrix Intercom System. Mentor RG + MasterMind Sync and Test Pulse Generator

CREATE. CONTROL. CONNECT.

FS3. Quick Start Guide. Overview. FS3 Control

Broadcast Graphics ACSR BG400 Webinar Table Of Content

The New Reference Standard is Here!

8K120 Projection Application

Production Switcher Systems MVS-8000 Series DVS-9000 Series

LIVE PRODUCTION SWITCHER. Think differently about what you can do with a production switcher

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes

Broadcast H.264 files live with ATEM Television Studio!

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

Automated Production Control

AV for Education. Instructional AV Technology Solutions from Atlona

See It. Take It. Avenue Flexible Matrix Router

HD/SD Three-Layer Logo Keyers

TERMINOLOGY INDEX. DME Down Stream Keyer (DSK) Drop Shadow. A/B Roll Edit Animation Effects Anti-Alias Auto Transition

KM-H Series. Multi-format digital production switchers KM-H3000E KM-H3000U KM-H2500E KM-H2500U

EEG A1452 SCTE-104 Inserter Frame Card

MVS-7000X. High-end 3G / HD / SD switcher. Overview. Powerful production switcher upgrades from SD to HD

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

Ponderosa is expandable by 8 input and/or 8 output increments up to 64x64 in a 4RU frame. Typical Configurations:

UTAH 100/UDS Universal Distribution System

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

Case study WWAY station in a box

Using Virtual GPIO in Axia iq and Radius consoles

TallyMan UMD & Tally Systems

C ch optical MADI & AoIP I/O. MASTER mode: A C8000 frame may be clocked via MADI input or AES67 network. AoIP Dante Brooklin II OEM module

Cue tone encoding and decoding with the HSI21 module. 3Gb/s, HD, SD embedded domain Dolby E to PCM decoder with audio shuffler

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

MX-AIR : THE PERFECT TOOL FOR SWITCHING AUDIO & VIDEO

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

Design and Use of a DTV Monitoring System consisting of DVQ(M), DVMD/DVRM and DVRG

BrightEye NXT 410-H Clean HDMI Router with HDCP

Parade Application. Overview

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

Introduction. The Solution. Signal Processing

ON-AiR / PRODUCTiON DiGiTAl MixiNG CONSOle. A lot more broadcasting for a lot less money

NewsBase. Newsroom Systems. Equip your news operation to compete in any market.

CI-218 / CI-303 / CI430

STORQ System Installation Guide

This document describes the different ways to allow the automation system to close a gpi contact from the transmission list.

Ad Benchmark s Insertion Workflow. Increase revenues and flexibility with advanced regionalization for broadcast ads and programs

Feature Descriptions INDEX

C8491 C8000 1/17. digital audio modular processing system. 3G/HD/SD-SDI DSP 4/8/16 audio channels. features. block diagram

Network Camera Operating Manual

Multi Bit Rate Routing Switcher. HDS-X3000 Series. No Need to Hesitate Any Longer

TVU MediaMind Server. Monitor, control, manage and distribute all your video content. Advantages

TVU MediaMind Server. Monitor, control, manage and distribute all your video content. Advantages

VU + SOLO2 performance above all

Challenges of Launching DOCSIS 3.0 services. (Choice s experience) Installation and configuration

The. Checking it Out. The DASDEC-II EAS Encoder/Decoder. By Kevin Raper

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION VIDEO CONNECTIONS GENERAL PURPOSE INPUTS & OUTPUTS SPECIFICATIONS...

MAGIC THipPro. Signalling and Control with. Configuration Guide. using the example of a LAWO crystal mixing console. Version: March 26 th, 2018

BrightEye NXT 410 Clean HDMI Router

Software Tools The included Windows-based software tools allow easy graphics/clip management, multiviewer configuration, and macro creation.

Adtec Product Line Overview and Applications

ST60-DVC VTR CONTROLLER ST60-AG57 VTR CONTROLLER

DigiPoints Volume 2. Student Workbook. Module 1 Components of a Digital System

We all know that Ethernet and IP underpin

SAPLING MASTER CLOCKS

Optiflex Interactive Video System

The Switcher: TriCaster 855 Extreme

AWS-750. Anycast Touch portable live content producer. Overview

HDMI / Video Wall over IP Receiver with PoE

Users Manual Firmware 2.03 September 6, 2017

1. Get support Attention Safety Caution Applications View Cameras on Screen (ex. HD TV or PC monitor) 3. Change Time Zone 5

NV5128-MC MULTI CHANNEL MASTER CONTROL SWITCHER

BecauseRFL andhubbel haveapolicyofcontinuousproductimprovement,wereservetherighttochangedesignsandspecificationswithoutnotice.

SAPLING WIRED SYSTEM

UCR 2008, Change 3, Section 5.3.7, Video Distribution System Requirements

3G/HD/SD dual channel audio embedder/de-embedder

Users Manual Firmware 1.06 October 12, 2016

Digital audio is superior to its analog audio counterpart in a number of ways:

USO RESTRITO. DENSITÉ series LGK G/HD/SD Logo Inserter & Downstream Keyer DSK-3901

Television Centre. 1. Television center structure

NTSC/PAL. Network Interface Board for MPEG IMX TM. VTRs BKMW-E2000 TM

ATEM 2 M/E Broadcast Studio 4K

Video Server SED-2100R/S. Quick Installation Guide

RCP Manual. Congratulations! RCP Version 1.0

Create. Control. Connect.

Transcription:

12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com www.dnfcontrols.com helps you solve equipment interface, control and monitoring problems, quickly and easily Is unlike anything on the market Offers simple, cost-effective, and easily accessible solutions Controls and monitors equipment in the same room, on another floor, in another building, across town, and around the world Supports GPI/O, Serial, Ethernet, LAN, WAN, VPN, Internet, TCP/ IP, UDP, SNMP, SCTE, and more Works with a wide range of broadcast and production equipment VTRs, DDRs, video servers, graphics systems, logo inserters, video routers, video switches, production switchers, master control switchers, multi-viewers, camera tallies, on-air tallies, audio devices, camera pedestals, and more... Supports an extensive list of equipment control protocols Is a control infrastructure that is expandable and adaptable Can be easily configured and re-configured as equipment and the needs of the facility change No programming or scripting required. A Problem Solver For Time triggered events Time delayed events Monitor Wall text and tally control On-Air tallies EAS crawls and audio-overs VTR / DDR / Video Server play out control and monitoring GPI routing Router control and monitoring Graphics control SCTE command generation SCTE A/B Switch SNMP message generation Camera tally control, local and remote Video A/B Switch control and monitoring, local and remote Shared control between control positions and control facilities Page 1

gives you the tools to easily solve control and interface problems Production Control Rooms #1 and #2 share cameras in Studio #A PCR #1 controls the camera tallies for the morning & afternoon shows. PCR #2 controls them for the evening shows When a PCR is controlling the camera tallies, it also needs to control the Studio On-Air lights The GTP-32 makes it so easy to respond to Operation s requests and changes. What used to take days and weeks can now be done in hours. With the GTP-32, I finally have a control system that does what I want it to do. I can easily change configurations by myself. The GTP-32 is used throughout the building for passing tallies, controlling graphics, rolling automation breaks, delegating control between studios, driving monitor walls, controlling on-air lights, and providing equipment error indicators. It is the control backbone. Fred mounts relays on a board to control 3 camera tallies and 2 studio On-Air lights. He runs wires from control rooms to studio. He mounts a switch in each PCR to take control of the camera tallies. The camera tally system works fine. Time passes and Fred is promoted and moves into another department. Joe takes over the camera tally system. He is asked to add 2 more cameras. He discovers that the system can not be easily expanded. Joe replaces the existing sytem with a GTP-32. He wires PCR tallies to GTP-32 GPIs. He wires camera tallies and studio On- Air lights to GTP-32 GPOs. PCR #1 STD #A PCR #2 Joe uses a web-browser to configure the GTP-32 inputs and outputs for 5 camera tallies and 2 On-Air lights. Oops. Another change. Make that 6 cameras and 3 On-Air lights. Page 2

When you need to push a button... Create a button panel solution by simply connecting a Universal Switch Panel to your GTP-32 Control Processor Tom in Operations tells Joe in Maintenance that the producer in PCR1 needs a button panel to change on-set graphics during his show. by the end of the week USP-16 Universal Switch Panel The USP / GTP-32 combination opens the door to endless control & statusing possibilities When used with the GTP-32, one USP panel can control graphics, A/B switching, roll clips, change routers, control keyers, you name it. LAST YEAR. Joe looks for a metal panel, buttons, and wire to build a button panel Joe drills holes, mounts buttons, and solders wires. He runs wires from PCR 1 to the equipment room. He installs and tests. Joe, the producer wants one more button and make them all green backlights Joe is not done THIS YEAR. Joe installs a USP-16 push-button panel in PCR1. He runs a cable from the existing GTP-32, in the equipment room, to the graphics playout device, two racks over. Joe uses a web-browser to configure the USP and GTP-32. He assigns legends and colors to the 5 USP keys. He assigns a USP key to each GTP-32 GPI Output, to select a graphic. Joe, the producer wants one more button and make them all green backlights Joe assigns a legend and color to another USP key. Then, on the GTP-32, he assigns the graphic to be controlled. He changes all key colors to green. Page 3

Equipment & technology continually change forcing you to adapt. Use the GTP-32 to Change GPI control to serial and Ethernet control. Change serial and Ethernet status to GPI status. Take GPI triggers from old reliable to control and monitor the new gear. Routers, switchers, graphics, video servers, DDRs, multi-viewers, tally systems,... The original graphics system supported GPIs for triggering graphics. It is no longer supported and breaks down frequently. Recently, it was replaced with a new unit that requires a serial connection to control graphics. The goal is to use the existing button panels and graphics control system, just change the interface from the original device to the new The GTP-32 is so simple to setup. select from a list of source events, assign an action, and then try it. Easy to tweak to get it just right. No programming. No scripting. The built-in diagnostic tools and logs eliminate the guesswork. The existing switch panels connected to a local GTP- 32 in Transmission. The new equipment and GTP-32 was installed down the block in the new building. Configured the GTPs and connected them together. Worked the first time and kept on working. Was monitoring an old style switcher using serial to the GTP-32. Driving on-air lights and monitor wall tallies. Got a new Ethernet based switcher. Got the new protocol from DNF and installed an Ethernet cable. The GTP-32 allowed us to mix old and new equipment in the facility. Over time the old will be replaced by new, but workflow will remain the same. Joe installs a GTP-32 in the equipment room near the original graphics system. He runs a cable to the original system s Inputs and Outputs. He runs another cable to the new graphics device. Joe connects the original system to the GTP-32's GPIs and GPOs. He connects a GTP-32 serial port to the new device. Joe uses a webbrowser to configure the GTP-32 GPIs, GPOs and serial port He tests the system. It works. Page 4

You need to connect equipment located on different floors and in different buildings. Running multi-core cable is not an option.. Place GTP-32s where you need them around the facility, between facilities, at remote locations. Connect them together over LAN, WAN, or the Internet. During Breaking News events, you share stories with other stations in your group. Sometimes you roll stories from your video server. Sometimes you provide a live feed from your newsroom. Sometimes you do both. To prevent mistakes you need On-Air tallies back from the sister station when they put your video server or studio on-air. LAST YEAR. The GTP-32 is used to pass tallies between facilities in the north and south of the country. Set it and forget it. Easily make changes for special events, maintenance, and new equipment. Setting up the GTP-32 is easy. Select a GPI. Assign it to a GPO. Assign it to 2 GPOs. Repeat for each GPI. Save one configuration for each studio. Use a GPI to recall the correct configuration. Troubleshooting tallies is simple. Punch up source on switcher then check GPI web page. Is it on? Which one is on? Use the diagnostic tool to turn on/off GPOs, one at a time. Pete in Station A calls Jim in Station B to request a story feed. Jim loads the story on a video server playout channel and waits.. Pete calls back, Roll the story! Jim rolls the story, then gets called to the equipment room. The director tells Joe to review the stories for the Evening News. Joe grabs an used video server channel and accidentally stops the feed to Station A. THIS YEAR. Pete in Station A calls Jim in Station B to request a story feed. Jim loads the story on a video server playout channel and delegates control to Pete at Station A. Pete rolls, recues and then rolls the story to air from his USP-16 panel. An On-Air light next to the video server in Station B turns on. The director tells Joe to review the stories for the Evening News. Joe sees that the video server channel is in use and finds another one. Page 5

Your facility has a specific workflow with specific control needs. Operations wants to minimize changes to their workflow. You just bought a new device that does not provide the hardware panels that they need. Using the GTP-32, create a custom, off-the-shelf, control system that meets Operations needs. The new camera switch you just bought is state of the art technology with fiber optic camera routing using light wave circuits. The only problem is that the user has to use a Windows application to do camera switching. Operations wants a push button panel with status. Every time a new control issue crops up, I call DNF. If the GTP-32 doesn t already do it, they help me find a solution or add the needed function. I use it for just about everything. Is there anything the GTP doesn t do? With the GTP-32, I finally have a control system that does what I want it to do. I can easily change configurations by myself. The GTP-32 makes it so easy to respond to Operation s requests and changes. What used to take days and weeks can now be done in hours. The GTP-32 and USP-16 is what we use to solve operator control problems. They are all over the plant. At the next Engineering staff meeting, the team explores its options for solving the problem. Changing camera switches is not an option. Making Operations use a mouse and keyboard is also not an option. After a little research, it is learned that the camera switch can be remotely controlled. Reviewing the list of available control equipment in-house, there is a GTP-32 and USP-16 with some unused keys. DNF can support the new camera switcher control protocol on the GTP-32. The new protocol is installed on the GTP-32. It is configured to control and monitor the camera switch. The operators use the USP-16 to select a camera. Page 6