CountDown Touch User Manual

Similar documents
FiliBuster. User Manual

HD Digital MPEG2 Encoder / QAM Modulator

Warnings and Precautions

Winmate Communication INC.

Camera 220C Document Camera User s Guide

HD Digital MPEG2 Encoder / QAM Modulator

HD Digital MPEG2 Encoder / QAM Modulator Get Going Guide

CU103 User Manual. Contents

AUTO - SCANNING WITH DIGITAL CONTROL LCD COLOR MONITOR FS-L1903C. User manual (Rev.01) SMITHS HEIMANN

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

Amplified TV Antenna VIDEO. Band Separator. Matching Transformer. 120 VAC, 60 Hz to 12 VDC, 200mA Wall Adapter ANT200

DC162 Digital Visualizer. User Manual. English - 1

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

HD Digital Set-Top Box Quick Start Guide

Installation Manual VIP 1003

DDW36C Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

Operating Instructions

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

27'' Full HD LED Monitor KALED27MONSC Quick Start Guide

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

LINK-MI LM-WHD05B. Wireless HDMI AV Transmission System. User Manual

Evolution Digital HD Set-Top Box Important Safety Instructions

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

Disclaimer of Product & Services The information offered in this instruction manual is intended as a guide only. At all times, Datavideo Technologies

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

INSTRUCTION MANUAL. ANI-1x2COMPDA. 1x2 Component Video(RCA) Splitter Distribution Amplifier w/ Digital Coaxial/Optical Audio

RemotePoint. Navigator. User s Manual VP4150


FD Trinitron Colour Television

28 4K LED monitor. User Manual M284K

USER MANUAL MX102 & MX1202

ZvBox 150. HD video distribution over COAX Get Going Guide

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL


HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

Monochrome Video Monitors

Stereo Cassette Deck

TFT LCD MONITOR USER MANUAL. L80AP and L101AP

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

PNP300 / PNP300UN / PNP350

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

User Manual MagniLink Mira

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

STEREO OR MONO CONTINUITY TM POWER AMP

S MiX 2M2S UF. S MiX 2M2S F

USER GUIDE MULTI-CHANNEL STEREO MIXER S MIX 4M2S UD

SAFETY INFORMATION. 7. Do not force switched or external connections in any way. They should all connect easily, without needing to be forced.

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

SAFETY WARNINGS AND GUIDELINES... 3 INTRODUCTION... 4 CUSTOMER SERVICE... 4 PACKAGE CONTENTS... 4 RECOMMENDED TOOLS... 6 CONTROL PANEL OVERVIEW...

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

Table of Contents FCC COMPLIANCE STATEMENT... 4 WARNINGS AND PRECAUTIONS... 4 WARRANTY... 5 STANDARD WARRANTY... 5 TWO YEAR WARRANTY... 5 DISPOSAL...

Stereo Cassette Deck

Stereo Cassette Deck

PNP300 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE

Get Connected. Download the free Pure Connect app to immerse yourself in music.

Contents. Disclaimer of Product and Services

Passport Player Owner s Manual

OPERATING INSTRUCTIONS TOM-0431IP

Multi-Channel Passive Transceiver Hubs Installation Sheet

Electro Magnetic Compatibility (EMC) Warning. Important notes for users in the U.K. FCC declaration. Caution. Fuse

.Power Distribution Center. PD-1. Instruction Manual

Model 1421 Distribution Amplifier

4 PORT HDMI SWITCH

2.0 Wall Mount TV Soundbar Instruction Manual

Stratos Duo RGB. User Manual. Order code: EQLED371

Fusion 120 Zoom. User Manual. Order code: EQLED068

DisplayPort Extender over 2 LC Fibers

INSTALLATION MANUAL VIP 1903 / VIP 1903 T VIP 1963 / VIP 1963 T

EN - English Washington Street Melrose, MA Phone Toll Free Revision 4 20/06/17

APS W 12 inch. APS W 15 inch. 2 Way Active PA System with 3 Channel Mixer. 2 Way Active PA System with 3 Channel Mixer.

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

USER MANUAL. KW-11T Wireless High Definition Transmitter. KW-11R Wireless High Definition Receiver MODELS: P/N: Rev 9

MONOPRICE. BitPath AV 4K 1X4 HDMI Splitter Extender over Single Cat6 with IR, 120m. User's Manual P/N 16286

CAMERA KIT USE AND CARE GUIDE. Black & White Plastic Casing Camera Kit

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

MONOPRICE. Blackbird 4K HDBaseT Extender Kit. User's Manual P/N 21792

MONOPRICE. BitPath AV VGA Extender over Single Cat6 Cable, 120m. User's Manual P/N 16226

2.4GHz Digital Wireless Video Door Phone User Manual

9.7-INCH VALUE LED MONITOR

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

DISTRIBUTION AMPLIFIER

Welcome to NEED HELP? DIRECTV offers the best entertainment experience. Use this guide to make the most of it LKR FCC ID : ORS

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

9" B/W MONITOR CEM-09/09A-2 12" B/W MONITOR CEM-12/12A-2 OPERATION MANUAL

OPERATIONS MANUAL FOR EDISON PROFESSIONAL Professional ABS Molded Loudspeaker M4000

NS-3 RF Noise Source Operation Manual

PL2410W LCD Monitor USER'S GUIDE.

2.4 GHz WIRELESS SURVEILLANCE SYSTEM

TP HDMI OVER ANYWIRE TRANSMITTER

MONOPRICE. BitPath AV VGA Wireless Transmitter & Receiver Kit, 200m. User's Manual P/N 16224

ACUBRITE 23 SS. Manual. Stainless Steel Chassis 23" LCD Display. Content

CR42 LANCASTER

LED Widescreen LED Security Monitor USER GUIDE Cincinnati Avenue, Rocklin, CA Rev.

PLL2210MW LED Monitor

CM-S23349SV. Vari-Focal IR Bullet Camera

Register your product and get support at SDV5122/27. EN User manual

Picture Fan. display your photos, graphics & messages

Transcription:

CountDown Touch User Manual Cueing and Presentation Control Specialists 1

Contents Introduction...3 Safety Instructions...4 Setting Up...5 General Features...6 Operating Instructions...7 Programming...8 Setting Count Down Editing running Time Programming Memory Tools Environmental...9 Declaration of Conformity...10 FCC...11 Technical Support Contact...11 2

Introduction CountDown Touch is the ideal product for those events running to tight schedules. The easy to navigate intuitive touch screen can be operated by the technician. CountDown Touch works by displaying either real time or the elapsed/remaining time on discreet numeric displays for the benefit of a presenter. The system can be set to any required duration up to the maximum of 99 minutes and 59 seconds and can count up or down. CountDown Touch can also display the real time of day. To remind the presenter to summarize and conclude, the display digits can also be programmed to change colour from Green to Amber to Red. A range of numeric tri-colour displays are available for long distance and up close viewing and Intelligent Lamp and Light Tower options can also be used to only show the colour change. Professional Presenter Timekeeping We hope that CountDown Touch exceeds your expectations and welcome any feedback that you have about this or any of our products. Thank you. The Interspace Industries Team www.interspaceind.com 3

Safety Instructions All safety and operating instructions should be read before this product is operated and should be retained for further reference. Please adhere to all the warnings on this product and in these operating instructions. Please follow these instructions carefully. Power. Only use the power source indicated on the device. Devices equipped with a grounded plug should only be used with a grounded type outlet. In no way should grounding be disconnected, modified or suppressed. Power Supply Lead. To unplug the device always pull by the plug itself, not the power supply lead. The power source outlet should always be near the CountDown Touch main unit and easily accessible. Ensure the power supply lead cannot be walked on or damaged by items placed on or against it. Do not use if the power supply lead is damaged. Using the device with a damaged power supply lead may expose you to electric shock or other hazards. Check the condition of the power supply lead regularly. Contact your dealer or service centre immediately for a replacement if damaged. Keep Away From Harmful Substances To prevent the risk of electric shock and fire, do not expose this device to rain, humidity or intense heat sources (such as radiators or direct sunlight). Avoid using this equipment in environments where there is excessive heat, dust, moisture, chemicals, vibration or mechanical shock. Slots and Openings. These are designed into the device for ventilation and to avoid overheating. Always ensure these openings remain clear. Do not attempt to insert anything into these openings under any circumstances. If liquids have been spilled on, or objects have fallen into the product it must be checked by a qualified technician before reusing. Connections. All inputs and outputs (except for power input) are TBTS defined under EN60950. DO NOT OPEN SYSTEM DUE TO HIGH VOLTAGE. DO NOT IMMERSE IN WATER. 4

If you have any queries regarding these safety instructions or how to maintain the unit please do not hesitate to contact us on: +44(0) 870 770 8088 Servicing. Do not attempt to service this product yourself. Should an unauthorised person attempt to either open the covers or service our products, it may invalidate your Limited Factory Warranty. In addition, opening or removing covers and screws may expose you to electric shocks or other hazards. Refer all servicing to a qualified service personnel. Setting Up All connections can be made using standard 3-pin XLR (mic) cables. CountDown Touch can be set up and operated over a combined total distance of no more than 100 meters (300 ) to the remote displays. Main Lectern : Support Lectern : Stage CountDown Touch Control Desk Figure 1 Connections Diagram Note: A combination of displays and optional intelligent lamps can be added to the system using standard mic cable splitter (3-pin XLR type), such as our own Splixler product thereby providing for multiple displays, for instance displays located on more than one lectern. The sum of the total distance between all displays and the main unit should not exceed 100m(300 ). 5

General Features Count Up or Down. The system can be programmed to run a timer that counts up or down. Count Below Zero. The system can be set to continue counting below zero when countdown has finished running. Colour Changes. The system can be programmed to change the colour of the remote display at pre-determined times during a timer profile. This provides a means of emphasising elapsed or remaining times. The remote displays can change from green to amber to red for remaining times. It can also be changed manually at any time during the profile. Note: The twin LED colon between the hours and minutes digits on the remote displays is coloured red when the digits are either amber or green, and green when the digits turn red. Intelligent Lamp Option. In addition to the numerical remote displays, tri-coloured Intelligent Lamps can be used to simply display the colour changes to further emphasise the stages of the elapsed or remaining time. The lamps will change colour in the same way as the numerical remote displays, according to the programming of the profile that is running. Flash Mode. At any time the remote displays and/or intelligent lamps can be made to flash to further emphasise the elapsed or remaining time. The flash feature can be used while displaying real time in clock mode also. Pause Mode. At any time while a profile is running the remote display can be paused by selecting the Pause button from the main screen. This can be resumed at any time by pressing Go again which will take the system out of the pause mode. The real-time clock will continue to run despite the pausing of the time profile. Programming On the Fly : CountDown Touch is designed so that an operator can program or edit timer profiles at any time while another timer profile is running or the system is in clock display mode. This allows for easy adjustments to the timing of an event whenever required. 6

Colour change. While a profile is running, a colour change can be implemented immediately by selecting the chosen colour on the touch screen. Specifications: Power 100-240VAC Signals 2xXLR out carrying data and 12V USB in for System Firmware update Dimensions mm (inch) D x W x H 110 (4 ¼ )x165 (6 ½ )x185(2¼ ) Weight 880g(31oz) Note XLR cable is not supplied as standard. AC Power in XLR Outputs for Numeric Displays USB input for firmware update Operating Instructions Unpacking and Connections. Unpack the main unit and place on a flat surface within easy reach of the operator. Unpack and position the remote display where it can be viewed by the presenter and connect this to the main unit using standard 3-pin XLR (mic) cables. 7

Apply power to the main unit using the universal IEC power connector input on the back of the main unit. The touch screen will display a Splash Screen Page with the option to continue or to be directed to the Help pages. The remote displays will remain off until either one of the profiles has been started or the clock mode has been selected. Programming a Timer Profile (Information about programming can also be found under the Help pages on the device itself) Please make sure you are using the latest firmware version. For the latest firmware update go to our website www.interspaceind.com. Setting Count Down To set count down time use the up and down arrows buttons. Use these buttons to set the total Green time and for setting Amber and Red Times. Push the Go button and the time will start counting down. Pushing the same button will pause the timer. The Off button will turn off the display but the selected profile will continue to run. Selecting one of the three traffic lights buttons will force the display to this colour and override the present colour. Select the same traffic light button again to turn off, the display will then return to the original colour. Editing running time Use the Update button and the Green time to cut or extend the display time while running. For example, to cut the display time by 2 minutes reduce the Green time by 2 minutes then push Update. There is no Update function on the Count Up screen. Min/Sec button The system powers up in minutes mode (Min) where just the minutes can be changed. To change to seconds select the Min button to show Sec and set the seconds for the Green, Amber and Red times. The Zero button causes the Green, Amber and Red times to be set to zero. Use this in conjunction with the Update button to end a Count Down. 8

Use Restart to reload the current selected profile into the main display. Note this will only work if the timer is paused or stopped. The Flash button causes the main display to Flash. Note this cannot be used together with the On/Off button. Programming Memory In the top left corner of the main screen there are 4 icons for Countdown, Countup, Memory and Tools. To change from countdown to countup you must pause or stop the timer. The Memory and Tools buttons are immediate. The Memory page uses containers on the right side of the screen. Select which one of the 4 memories you want to edit, select count up or down. On the left select a container to edit the time, enter a new time and push the container again to save that time. Push Load to run the selected Memory. Tools The Tools screen allows setting the time of day and time format. Use the Set Time of Day button to enter time of day edit mode. You can enter time in 12 or 24 hour format. Once complete push the Store button. Use the Time to Day button to show the time in the main display. Use the Count Past Zero button to keep counting down after 00:00 with negative time. In addition, you can turn off key-click and finally, the Tools screen also provides access to the help screens. Environmental WEEE and RoHS2 Compliance. CountDown Touch and its associated accessories have been manufactured and sold in accordance with the requirements of the ECEE and RoHS2 directives. Please return all end-of-life items to your supplier, or your local Interspace Industries representative directly, for appropriate disposal. Packaging Materials: Cardboard box: Grade 150K/T B (Single Walled Corrugated- Brown Kraft) Protective Foam: Grade HLB 22 Grey Foam (High Load Bearing) 9

DECLARATION OF CONFORMITY We declare under our sole responsibility that the products: CountDown Touch Maxi Display Big Display Standard Display Mini Display Combi-Lamp ( part No s: CDTOUCH, CDd5i, CDD3i, CDD1,CDD05i, CDIL ) Conform to the following standards: EN 62368-1:2014 Audio/Video, Information, Communication technology equipment Part 1: Safety Requirements EN 55103-1:2009 (Emissions) / EN 55103-2:2009 (Immunity) Following the provisions of the EEC Directive 2014/30/EU and 2014/35/EU Issued on: Date April 2016 Signed Dave Humphrys, Managing Director Interspace Industries Unit 7, 41 Brownfields Welwyn Garden City Herts AL7 1AN UK 10

FCC Compliance Information Statement Declaration of Conformity This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. We, Interspace Industries, have determined that the above named equipment has been shown to comply with the applicable technical standards. Furthermore, we warrant that each unit of equipment marketed is identical to the unit tested and found acceptable with the standards. The records maintained continue to reflect the equipment being produced within the variation that can be expected due t quantity production and testing on a statistical basis. Manufacturer: Responsible Party in the USA: Interspace Industries Interspace Industries 4650 South Butterfield Drive Tucson AZ, 85714 Tel Office: 520 689 4237 Product: CountDown Touch, Maxi Display Big Display, Standard Display Mini Display, Combi-Lamp Authorisation Procedure: Declaration of Conformity Equipment Supplied 1x CountDown Touch Main Unit 1x Main Lead 1x USB Cable For Technical Support Or Sales Enquiries: Interspace Industries Head Office: +44 (0) 1462 600101 Emergency Technical Support Hot Line: +44 (0) 7976 385 046 Website: www.interspaceind.com 11

12 Unit 7, 41 Brownfields Welwyn Garden City Hertfordshire AL7 1AN UK Tel: +44 (0) 1462 600101 Email: moreinfo@interspaceind.com www.interspaceind.com