Manual Motor Starter Specifcations

Similar documents
llen-bradley 194R-HM4-NFPA3

AS09..S 3-pole Contactors - Spring Terminals

Series CT7N Bimetallic Overload Relays

Bulletin 190 IEC Modular Starter System

Type: DILM25 10(24V50HZ) Article No.:

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Type: DILM12 10(24VDC) Article No.:

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

02/11/2015

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

ALLEN BRADLEY TIMING RELAY

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

GV2ME. Main. Device short name. Device application

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Minicontactorrelay,2NO/2NC,DCoperated

A V 50Hz / V 60Hz

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Bulletin 100-G IEC Contactors

Datasheet - SRB301LC 24VAC/DC

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnecraft Power Relays

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

GV2ME. Main. Device short name. Device application

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Ordering details. Approval. Classification

High performance circuit breakers

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Datasheet - SRB-E-201ST

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

GV2P05. Main. Device short name. Device application

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Bulletin 100-G IEC Contactors

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Modular pulse operated latching relay 16 A

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Gamma instabus. Technical product information

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Circuit-Breakers for Motor Protection Series 8523/8

TeSys circuit-breakers

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors

Power Circuit of a UL508A Panel. Typical UL489 Application

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

16 A and 25 A power contactors with or without handle

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Interface Relays and Optocouplers Product group picture

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

Features XT SC 012 B B A

Features XT SC 012 B B A

Bulletin 305 AC Starters

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Safety dialogue solutions

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Definite Purpose Contactors

Generator protection relay

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Data Sheet Definite Purpose Contactors Ex9CK Series

VAT 20 Adjustable Frequency Drive

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Transcription:

Technical Data Manual Motor Starter Specifcations Bulletin 140A Topic Page Product Selection 2 Accessories 3 Specifications 6 Approximate Dimensions 13 Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Product Certifications website, http://www.rockwellautomation.com/global/ certification/overview.page Description Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/global/literature-library/ overview.page. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.

Product Selection 3-pole Manual Motor Starter Rated Operational Current I e [A] Auxiliary Contacts Motor Current Adjustment Range [A] (1) Power ratings: Preferred values according to IEC 60072-1 Magnetic Release Operating Current [A] Switching of Standard 3-phase AC Motors, AC-2, AC-3 I cu = I cs 3-phase [kw] (50 Hz) (1) 3-phase [Hp] (60 Hz) [ka] 230V 400V 690V 230V 460V 575V 400/415V Cat. No. 0.16 0.1 0.16 1.8 0.02 65 140A-C2A-A16 0.25 0.16 0.25 2.8 0.06 65 140A-C2A-A25 0.4 0.25 0.4 4.4 0.09 65 140A-C2A-A40 0.63 0.4 0.63 6.9 0.06/0.09 0.12/0.18 0.25 65 140A-C2A-A63 1 0.63 1.0 11 0.12 0.25 0.37/0.55 1/2 3/4 65 140A-C2A-B10 1.6 1.0 1.6 18 0.18/0.25 0.37/0.55 0.75/1.1 1 1 65 140A-C2A-B16 2.5 1.6 2.5 28 0.37 0.75 1.8 3/4 1-1/2 2 50 140A-C2A-B25 4 2.5 4.0 44 0.55/0.75 1.1/1.5 2.2/3.0 1 3 3 10 140A-C2A-B40 6.3 4.0 6.3 69 1.1/1.5 2.2 2 5 5 10 140A-C2A-B63 10 6.3 10 110 2.2 3.0/4.0 3 7-1/2 10 8 140A-C2A-C10 16 10 16 176 3.0/4.0 5.5/7.5 5 10 15 6 140A-C2A-C16 Description Connection Diagram For Use With Pkg. Qty. Cat. No. 13 14 140A-C-AEA10 I > 33 Auxiliary Contact for Flush Mounting 1-pole No additional space required I > 34 11 140A 1 140A-C-AEA210 12 140A-C-AEA01 I > 31 32 140A-C-AEA201 I > 13 23 14 24 140A-C-ASA20 I > Auxiliary Contact for Left-side Mounting 2-pole Adds 9 mm to the width of the Manual Motor Starter Use compact bus bars with 54 mm spacing I > 13 21 14 22 140A 1 140A-C-ASA11 11 21 12 22 140A-C-ASA02 I > 2 Rockwell Automation Publication 140A-TD001B-EN-P - December 2017

Accessories Description Trip Rating Connection Diagram Undervoltage Trip Release For right-side mounting Adds 18 mm to the width of the Manual Motor Starter Shunt Trip Release For right-side mounting Adds 18 mm to the width of the Manual Motor Starter For Use With Pkg. Qty. Cat. No. 24V, 60 Hz 140A-C-UXJ 24V, 50 Hz 140A-C-UXK 48V, 60 Hz 140A-C-UXX 220 230V, 50 Hz 140A-C-UXF 240V, 50 Hz/277V, 60 Hz D1 140A-C-UXT 400V, 50 Hz/460V, 60 Hz U < 140A-C-UXN 140A 1 415V, 50 Hz/480V, 60 Hz D2 140A-C-UXB I > 500V, 50 Hz/575V, 60 Hz 140A-C-UXM 110V, 50 Hz/120V, 60 Hz 140A-C-UXD 240 260V, 60 Hz 140A-C-UXA 110V, 50/60 Hz 140A-C-UXKD 525V, 50 Hz/600V, 60 Hz 140A-C-UXVC 24V, 60 Hz 140A-C-SXJ 24V, 50 Hz 140A-C-SXK 48V, 60 Hz 140A-C-SXX 220 230V, 50 Hz 140A-C-SXF 240V, 50 Hz/277V, 60 Hz C1 140A-C-SXT 400V, 50 Hz/460V, 60 Hz 140A 1 140A-C-SXN 415V, 50 Hz/480V, 60 Hz I > C2 140A-C-SXB 500V, 50 Hz/575V, 60 Hz 140A-C-SXM 110V, 50 Hz/120V, 60 Hz 140A-C-SXD 240 260V, 60 Hz 140A-C-SXA 525V, 50 Hz/600V, 60 Hz 140A-C-SXVC Description Terminal links For Use With Pkg. Qty. Cat. No. 2 x 3 140A-C-W452 Compact Bus Bars 3 x 3 140A-C-W453 45 mm spacing for manual motor starters with flushmounted auxiliary contact blocks 4 x 3 140A-C-W454 140A 1 5 x 3 140A-C-W455 Compact Bus Bars 54 mm spacing for manual motor starters with sidemounted auxiliary contact blocks 2 x 3 140A-C-W542 3 x 3 140A-C-W543 140A 1 4 x 3 140A-C-W544 5 x 3 140A-C-W545 Bus Bar Feeder Terminal Supply of compact busbars Increases wiring capacity 140A-C-W 1 140A-C-WT Blank Space Cover For covering unused terminal links Must be ordered in multiples of 10 (10 pcs/pkg) Screw Adapter Hat (DIN) Rail 35 x 7.5 mm, length 44 mm 140A-C-W 1 140A-C-WS 140A 1 140A-C-N12 Rockwell Automation Publication 140A-TD001B-EN-P - December 2017 3

Description For Use With Pkg. Qty. Cat. No. Protection Class: IP41 140A 140A-C-EA41 Enclosures for Surface Mounting With center marks for two indicator lights Includes protective earth and neutral wire terminals Enclosures for Flush Mounting Includes protective earth and neutral wire terminals Protection Class: IP55 140A 140A-C-EA55 (with seal and protective membrane) 1 Protection Class: IP41 140A 140A-C-EE41 Protection Class: IP55 (with seal and protective membrane) 140A 140A-C-EE55 Button Membrane For IP55 enclosures Replacement part with four screws (mounting frame included) 140A-C-EA55 140A-C-EE55 1 140A-C-N55 Locking Arrangement For locking ON-button of the Manual Motor Starter For 1 3 padlocks with ø 4 6 mm 140A 1 140A-C-M3 Locking Arrangement Suitable for 140A-C-E enclosures For 1 3 padlocks with ø 4 8 mm 140A-C-E 1 140A-C-M3E Emergency Stop Push Button Set For use with enclosures Twist to release 140A-C-E 1 140A-C-MT Emergency-Stop Push Button Set For use with enclosures Key release 140A-C-E 1 140A-C-MK 4 Rockwell Automation Publication 140A-TD001B-EN-P - December 2017

Description Color Voltage For Use With Pkg. Qty. Cat. No. 120V 140-LG120 240V 140-LG240 Green 400V 140-LG400 415V 140-LG415 480V 140-LG480 120V 140-LR120 240V 140-LR240 Red 400V 140-LR400 415V 140-LR415 Pilot Lights 198E-A Length of connection leads: 180 mm 480V 140-LR480 includes lamp 198E-C 1 120V 140-LW120 protection class IP54 140A-C-E 240V 140-LW240 White 400V 140-LW400 415V 140-LW415 480V 140-LW480 120V 140-LY120 240V 140-LY240 Yellow 400V 140-LY400 415V 140-LY415 480V 140-LY480 Rockwell Automation Publication 140A-TD001B-EN-P - December 2017 5

Specifications IEC Performance Data Cat. No. 140A-C2A- A16 A25 A40 A63 B10 B16 B25 B40 B63 C10 C16 Rated Operational Current I e [A] 0.16 0.25 0.4 0.63 1.0 1.6 2.5 4.0 6.3 10 16 Magnetic Release Current [A] 1.8 2.8 4.4 6.9 11 18 28 44 69 110 176 Switching of Standard Three-Phase Motors (1) AC-2, AC-3 230/240V [kw] 0.06/0.09 0.12 0.18/0.25 0.37 0.55/0.75 1.1/1.5 2.2 3.0/4.0 400/415V [kw] 0.02 0.06 0.09 0.18/0.25 0.25 0.37/0.55 0.75 1.1/1.5 2.2 3.0/4.0 5.5/7.5 500V [kw] 0.18 0.25/0.37 0.55/0.75 1.1 1.5/2.2 2.5/3.0 4.0/6.3 7.5/10 690V [kw] 0.25 0.37/0.55 0.75/1.1 1.8 2.2/3.0 Back-Up Fuses gg, am, only if I cc I cu 230/240V [A] No fuses required 50 400/415V [A] No fuses required 63 50 500V [A] No fuses required 63 50 50 690V [A] No fuses required 25 35 Ultimate- (I cu ) and Rated Service (I cs ) Short Circuit Breaking Capacity, I cu = I cs 230/240V [ka] 65 65 65 65 65 65 50 50 50 50 3 400/415V [ka] 65 65 65 65 65 65 50 10 10 8 6 500V [ka] 50 50 50 50 50 50 50 3 10 4.5 4.5 690V [ka] 50 50 50 50 50 50 4.5 2 (1) Power ratings: Preferred values according to IEC 60072-1. UL / CSA Performance Data Manual Motor Controller (UL 508, CSA C22.2 No.14, for group installation, in combination with a short-circuit protection device) Cat. No. 140A-C2A- A16 A25 A40 A63 B10 B16 B25 B40 B63 C10 C16 Max. short-circuit current 480V [ka] 42 42 42 42 42 42 42 18 18 10 5 600V [ka] 42 42 42 42 42 42 10 5 5 5 5 Motor load 1-phase 115V [Hp] 1/10 1/8 1/4 1/2 1 230V [Hp] 1/10 1/6 1/3 3/4 1-1/2 3 3-phase 200V [Hp] 1/2 3/4 1-1/2 2 3 230V [Hp] 3/4 1 2 3 5 460V [Hp] 1/2 1 1-1/2 3 5 7-1/2 10 575V [Hp] 3/4 1 2 3 5 10 15 Maximum rated current of protection device [A] 175 6 Rockwell Automation Publication 140A-TD001B-EN-P - December 2017

General Data Cat. No. 140A-C2A- Rated Insulation Voltage U i EN/IEC [V] 690 UL, CSA [V] 600 Overvoltage Category / Pollution degree lll / 3 Rated Impulse Withstand Voltage U imp Main circuits 6 kv Auxiliary circuits 6 kv Rated Frequency [Hz] 40 60 Life Span Mechanical [operations] 100000 Electrical (I e max.) [operations] 50000 Switching Frequency [operations/h] max. 30 Ambient Temperature Storage [ C] - 25 + 80 Operation [ C] - 25 + 60 Resistance to Climatic Stress C IV (according to IEC 68) Moisture/heat resistance 40 C, 92 %, 56 days Moisture/change resistance 23 C, 83 %/40 C, 93 %, 56 cycles Site Altitude [m] 2000 Protection Class IP20, when wired Resistance to Shock, transport [g] 30 g, 20 ms Resistance to Vibration Frequency range [Hz] 10 150 in all directions [g] 7.5 Rated Thermal Current I th IEC up to 40 C ambient temperature [A] 0.1 16 up to 60 C ambient temperature [A] 0.1 16 Rated Supply Current I e [A] 0.1 16 Number of setting ranges 11 Dependence on Temperature 40 C [A] 50 C [A] no reduction 60 C [A] 70 C [A] 15 % current reduction of the upper rated current I e Overload Protection Characteristics EN/IEC 60947-4-1 Motor protection Ambient Temperature Compensation [ C] -20 +60 Trip Class 10 Magnetic Release fixed setting Release current 11 x I e max. I e max. = maximum values of setting ranges Total Power dissipation Manual motor starter at rated load [W] 7 Main Supply Application Usable as main supply switch according to EN/IEC 60-204 with corresponding accessories Rockwell Automation Publication 140A-TD001B-EN-P - December 2017 7

Conformity to Standards Approvals/Markings Terminal Parts Type of terminals Cat. No. 140A-C2A- IEC 60947-1/ -2/ -4/ -5-1 UL 508 CSA 22.2, Part 1 CE, culus Listed Screwdriver Pozidriv No. 2/Blade No. 3 1 conductor [mm 2 ]/[AWG] 1 4/No. 16 12 2 conductor [mm 2 ]/[AWG] 1 4/No. 16 12 1 conductor [mm 2 ]/[AWG] 1 6/No. 16 12 2 conductor [mm 2 ]/[AWG] 1 6/No. 16 12 1 conductor [mm 2 ]/[AWG] 1.5 6/No. 16 12 2 conductor [mm 2 ]/[AWG] 1.5 6/No. 16 12 Tightening torque [N m]/[lb in] 2 2.5/18 22 Weights Description Cat. No. Weight Description Cat. No. Weight Manual Motor Starter 140A-C2A- 290 g Blank Space Cover 140A-C-WS 3.3 g Auxiliary Contact Blocks for Flush Mounting 140A-C-AEA 12 g 140A-C-EA41 250 g Enclosure for Surface Mounting Auxiliary Contact Blocks for Left-side Mounting 140A-C-ASA 35 g 140A-C-EA55 258 g Undervoltage Release 140A-C-UX 104 g 140A-C-EE41 126 g Enclosure for Flush Mounting Shunt Release 140A-C-SX 100 g 140A-C-EE55 134 g Bus Bar Feeder Terminal 140A-C-WT 36 g Button Membrane 140A-C-N55 8 g 140A-C-W452 42 g Indicator Light 140-L 10 g 140A-C-W453 69 g Hat (DIN) rail Adapter 140A-C-N12 16 g 140A-C-W454 94 g 140A-C-M3E 19 g Locking Arrangement 140A-C-W455 119 g 140A-C-M3 11 g Compact Bus Bar 140A-C-W542 45 g 140A-C-W543 76 g 140A-C-W544 104 g 140A-C-W545 135 g Cat. No. 140A-C-EA41 / -EE41 Enclosure Cat. No. 140A-C-EA55 / -EE55 Enclosure Cat. No. 140-L... Indicator light IP Protection IP41 IP55 (with seal and protective membrane) IP54 Ambient Temperature [ C] -25 +40-25 +40 Rated Operating Voltage [V] 120, 240, 415, 480 Cat. No. 140A-C-W45... Compact Bus Bar Cat. No. 140A-C-W54... Compact Bus Bar Rated Insulation Voltage U i [V] 690 690 Rated Thermal Current I th [A] 63 63 8 Rockwell Automation Publication 140A-TD001B-EN-P - December 2017

Accessory Specifications Cat. No. 140A-C-AEA... Auxiliary Contact Block for Flush Mounting Cat. No. 140A-C-ASA... Auxiliary Contact Block for Leftside Mounting Rated Thermal Current I th at 40 C ambient temperature [A] 6 10 at 60 C ambient temperature [A] 4 6 Contact Class Coordination According to NEMA (UL/CSA Standards) AC B 600 Standard Pilot Duty B 600 Standard Pilot Duty DC R 300 Light Pilot Duty R 300 Light Pilot Duty Back-Up Fuses gg, gl [A] 16 16 Rated Supply Current [V] 230/240 400/415 500 690 230/240 400/415 500 690 AC-15 [A] 2 1 0.8 0.5 2 1 0.8 0.5 DC-13 [V] 24 48 110 220 24 48 110 220 [A] 2 0.6 0.2 0.1 2 0.6 0.2 0.1 Terminal Parts Type of terminals Screwdriver Pozidriv No. 2/Blade No. 3 Pozidriv No. 2/Blade No. 3 1 conductor [mm 2 ]/[AWG] 0.75 2.5/No. 18 14 0.75 2.5/No. 18 14 2 conductor [mm 2 ]/[AWG] 0.75 2.5/No. 18 14 0.75 2.5/No. 18 14 1 conductor [mm 2 ]/[AWG] 0.75 4/No. 18 14 0.75 4/No. 18 14 2 conductor [mm 2 ]/[AWG] 0.75 4/No. 18 14 0.75 4/No. 18 14 1 conductor [mm 2 ]/[AWG] 0.75 4/No. 18 14 0.75 4/No. 18 14 2 conductor [mm 2 ]/[AWG] 0.75 4/No. 18 14 0.75 4/No. 18 14 Tightening torque [N m]/[lb in] 1 1.5/9 13 1 1.5/9 13 Actuating Voltage Rated Control Voltage Cat. No. 140A-C-UX... Undervoltage Release Unit for Right-side Mounting Cat. No. 140A-C-SX... Shunt Release for Right-side Mounting Cat. No. 140A-C-WT Supply Block Pull-in 0.8 1.1 x U s 0.7 1.1 x U s Drop-out 0.7 0.35 x U s min. 12V, 50 Hz; 14V, 60 Hz 12V, 50 Hz; 14V, 60 Hz max. 600V, 50 Hz 600V, 50 Hz On-Time 100 % 100 % Pull-in 8.5 VA, 6 W 8.5 VA, 6 W Coil Rating Hold 3 VA, 1.2 W 3 VA, 1.2 W Terminal Parts Type of terminals Screwdriver Pozidriv No. 2/Blade No. 3 Pozidriv No. 2/Blade No. 3 Pozidriv No. 2/Blade No. 3 1 conductor [mm 2 ]/[AWG] 0.75 2.5/No. 18 14 0.75 2.5/No. 18 14 4 16/No. 14 6 2 conductor [mm 2 ]/[AWG] 0.75 2.5/No. 18 14 0.75 2.5/No. 18 14 4 16/No. 14 6 1 conductor [mm 2 ]/[AWG] 0.75 4/No. 18 14 0.75 4/No. 18 14 4 16/No. 14 6 2 conductor [mm 2 ]/[AWG] 0.75 4/No. 18 14 0.75 4/No. 18 14 4 16/No. 14 6 1 conductor [mm 2 ]/[AWG] 0.75 4/No. 18 14 0.75 4/No. 18 14 4 16/No. 14 6 2 conductor [mm 2 ]/[AWG] 0.75 4/No. 18 14 0.75 4/No. 18 14 4 16/No. 14 6 Tightening torque [N m]/[lb in] 1 1.5/9 13 1 1.5/9 13 4/36 Rockwell Automation Publication 140A-TD001B-EN-P - December 2017 9

Cut-off Current The Bulletin 140A-C2A manual motor starter limits short-circuit current I cc (prospective short-circuit current). I D is the maximum cut-off current (highest instantaneous value of the limited short-circuit current). This value is indicated in Figure 1 as a function of the system short-circuit current. Figure 1 - Short-circuit Current Function I s I cc (asymmetrical) I D I cc (symmetrical) Figure 2-140A-C2A Max. Let-Through (cut-off) Current, U e = 400...415V 100 0.25 0.3 Max. Let-Through (Cut-Off) Current I D [ka] 10 1 cos 0.95 0.8 0.9 0.7 0.5 16 A 10 A 6.3 A 4 A 2.5 A 1.6 A 1 A 0.1 0.63 A 0.01 0.1 1 10 100 Prospective Short-circuit Current I cc [ka] 10 Rockwell Automation Publication 140A-TD001B-EN-P - December 2017

Figure 3-140A-C2A Time/Current characteristics 10000 2 h 1 h 1000 Specified limits in compliance with IEC 60947-4-1 from the warm state 100 (1) Mean value from the cold state Tripping time t A [s] 10 1 0.1 (2) 0.01 0.001 0.1 1 Multiple of the set current I ef Dispersion: t A ±20%, I ef ±10% 10 100 (1) Operating Current of Thermal Releases: The adjustable inverse bimetal trip reliability protects motors against overloads. The curve shows the mean operating current at an ambient temperature of 20 C starting from cold. In equipment at operating temperature, release time is less than or equal to release time from the cold state. (2) Operating Current of Magnetic Releases: Electromagnetic instantaneous releases react at a fixed tripping current. At the upper thermal release setting, this tripping current is 11 times the set current. Correspondingly, the maximum forward i 2 dt energy is limited. This value is indicated in Figure 4 as a function of the system short-circuit current. Rockwell Automation Publication 140A-TD001B-EN-P - December 2017 11

Figure 4-140A-C2A Max. Let-through Energy, U e = 400...415V 1000 100 1 Half Cycle (50 Hz) 16 A 10 A Max. Let-Through (Cut-Off) Current i 2 dt*10 3 [A 2 s] 10 1 6.3 A 4 A 2.5 A 1.6 A 1 A 0.1 0.63 A 0.01 0.1 1 Prospective Short-circuit Current I cc [ka] 10 100 Current To Be Set: Thermal releases meet the requirements for a thermal release of a starter in accordance with IEC 60947-4-1 f. If a different value is specified (such as reduced I e in motors with an ambient temperature higher than 40 C or a site altitude >2000 m above sea level), the rated operating current I e must be adjusted. Performance categories per IEC 60947-2 Current Description I cu Rated short-circuit breaking capacity Operational after completing O-t-CO test sequence O = off I CO = restart and off cs Ultimate short-circuit breaking capacity Suitable for normal operation after completing O-t-CO-t-CO test sequence t = set delay, 3 min 12 Rockwell Automation Publication 140A-TD001B-EN-P - December 2017

Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. (3) 9 45 (2) 18 60 (2-23/64) 4 (5/32) 44 6 (1/4) 23/64 (1-25/32) (25/32) (1-47/64) 24.5 (31/32) 44.5 (1-3/4) 14 14 (35/64) (35/64) 24 (15/16) 45 (1-25/32) 88 (3-15/32) 45 (1-25/32) 17.5 (11/16) 12 12 (15/32)(15/32) 140A-C-WT ø 4.8 (3/16) 30 (1-3/16) 140A-C-N12 (1) 140A-C2A (1) Can be mounted on DIN Rail EN 50 022-35 (2) Auxiliary contact block for side-mounting of 140A-C-ASA (3) 140A-C-SX shunt release or 140A-C-UX undervoltage release 12.3 (31/64) 24 (15/16) 107 (4-7/32) 113.5 (4-15/32) 140A-C2A with 140A-C-W 140A-C2A with 140A-C-WT 360 360 30 Mounting position/safety clearance of 140A-C2A Rockwell Automation Publication 140A-TD001B-EN-P - December 2017 13

Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 130 (5-1/8) 10 (25/64) 149 (5-55/64) 150 (5-29/32) Ø 5 (13/64) 137 (5-25/64) Ø 6.5 (1/4) 25 (63/64) 45 (1-25/32) 87 (3-27/64) M 20 M 25 140A-C-EA41, -EA55 47.5 (1-7/8 88 (3-15/32) 96 (3-25/32) Cutout R4 (5/32) 84...86 139...141 (5-15/32...5-35/64) (3-5/16...3-3/8) 140A-C-EE41, -EA55 74.5 (2-15/16) 90.5 (3-9/16) 14 Rockwell Automation Publication 140A-TD001B-EN-P - December 2017

Notes: Rockwell Automation Publication 140A-TD001B-EN-P - December 2017 15

Rockwell Automation Support Use the following resources to access support information. Technical Support Center Local Technical Support Phone Numbers Direct Dial Codes Literature Library Product Compatibility and Download Center (PCDC) Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates. Locate the phone number for your country. Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer. Installation Instructions, Manuals, Brochures, and Technical Data. Get help determining how products interact, check features and capabilities, and find associated firmware. www.rockwellautomation.com/knowledgebase www.rockwellautomation.com/global/support/get-supportnow.page www.rockwellautomation.com/global/support/directdial.page www.rockwellautomation.com/literature www.rockwellautomation.com/global/support/pcdc.page Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 140A-TD001B-EN-P - December 2017 Supersedes Publication 140A-TD001A-EN-P - September 2014 Copyright 2017 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.