Do you know if your Cat. 6 patch cord has been tested according to standards?

Similar documents
IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution. Presented by PowerDsine: David Pincu -

Challenges for testing 10GBASE-T

What really changes with Category 6

Volition TM RJ45 K5e Jacks

Data Communications Competence Center

CATEGORY 6A CABLING SOLUTIONS

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

CATEGORY 6A CABLING SOLUTIONS

LCS2 Cat. 6 RJ 45 Patch panels and units

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

technicalreport MegaLine Connect100 Class E A links over 100 metres in length Data communication technology 09/2018 Classic structure 2-connector link

Class E A / Cat.6A Screened Coupler

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

The need for Encircled Flux, real or imaginary?

LCS 2 RJ 45 Cat. 6A HD panels and units

Connect with the industry s best CAT6 and CAT5e channel solutions!

SECTION COMMUNICATIONS HORIZONTAL CABLING

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

DESIGN!!GUIDELINES!!!!!

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

SYSTIMAX GigaSPEED XL Solution

How to Implement PoE in Your Harsh Industrial Environment

TB876BSX-3WH Class E A / Cat.6A STP Keystone Jack (Auto press-fit)

Effective earthing of screened cables

Category 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards.

CATEGORY 6 CABLING SOLUTIONS

PREMIUM 5e F/UTP PRODUCTS

CATEGORY 5e CABLING SOLUTIONS

INTERNATIONAL STANDARD

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

Min Dynamic Bend mm. Min Static Bend mm. EF 008 Uni4 L STA LU FS. EF 008 Uni8 L STA LU FS. EF 008 Uni12 L STA LU FS. EF 008 Uni16 L STA LU FS

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

Interface Practices Subcommittee SCTE STANDARD SCTE Hard Line Pin Connector Return Loss

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

SMART CLASSix 24/48 UTP Patch Panels -

CAT5E NETWORK PATCH LEADS

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

C6 A modul and C6 A modul K. The new connection system for a wide variety of applications of course with Cat.6 A

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

SECTION COMMUNICATIONS HORIZONTAL CABLING

Information & Communications Technology Network Infrastructure Group. Network Infrastructure Standards June 2008

RCIT Cable Certification Testing Revised 10/2017

MILLIMETER WAVE VNA MODULE BROCHURE

TEST REPORT NO.: CRT-081 RENDERED TO: Hubbell Premise Wiring 14 Lord s Hill Road Stonington, CT

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

10 Mb/s Single Twisted Pair Ethernet Preliminary Cable Properties Steffen Graber Pepperl+Fuchs

Belden IBDN System 10GX The next level of cabling performance

(with. Meets. tools. Page 1 of 11

A guide to Woolworths Limited additional requirements. for the testing of twisted pair and fibre installation.

What Kind of Ethernet Cable Should I Use?

5e. Max bandwidth is 400MHz Cat 6 max bandwidth of 500MHz Cat 6E max bandwidth of 550MHz ( E stands for enhanced ) Cat 6A max bandwidth of 625MHz

The Telegärtner Group

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

By Jim Norton Bird Technologies Group Applications Engineer

Data Communications Competence Center

RJ45FC6-BLU. Base Data. Category 6 modular keystone jack - Blue - 1/bag. Article Number: Part No. RJ45FC6-BLU. Type RJ45FC6. Color.

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

o-microgigacn Data Sheet Revision Channel Optical Transceiver Module Part Number: Module: FPD-010R008-0E Patch Cord: FOC-CC****

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

TECHNICAL SPECIFICATION

LAN Cabling Systems Copper

SP205+ DUAL 1x5 VIDEO & AUDIO DISTRIBUTION AMPLIFIER

The University of Texas at Austin September 30, 2011

STRUCTURED CABLING SYSTEMS (SCS)

Copper Cabling Troubleshooting Handbook

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Mainline Pin (plug) Connector Return Loss

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling

Draft for Public Comment

GenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk

Table of Contents. Open Matrix System (OMS) 1-2

LANmark. Copper Cabling Solutions

PRODUCT INFORMATION. ETHERLINE EC Flex Cat.5e M8

CABLE LOSS MASKING EFFECT

CAT 6 Data Wiring System Connectors

Request for Proposal (RFP)

Agilent 81600B Tunable Laser Source Family

AMERICAN NATIONAL STANDARD

CAT6Plus System. Brand-Rex Limited

CAT 6 Data Wiring System Connectors

Cable matrix. strong in connectivity

TECHNICAL SPECIFICATION

FUTURE PROOF YOUR CONNECTIONS

LITWARRANTY Rev. 5 W a r r a n t y P r o g r a m S t r u c t u r e d C a b l i n g S y s t e m s

Copper Solution Contents Cabinets Fiber Optic Solution

Everything you always wanted to know about HDBaseT*

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

Marshall Electronics. Broadcast A/V Division VAC-HT12-KIT. 4K HDBaseT Extender Kit. User Manual

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

EMC TEST REPORT. Product : Digital Camcorder Model No. : SCD5000. SAMSUNG ELECTRONICS Co., Ltd. EMC Test Laboratory. Project No.

Data sheet. USB V2.0 Interactive panel extender. Product: SDS-1001-H CAT 6 extender

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

EXTENDER ELE8080. INSTALLATION Manual. Made in Taiwan

How to accelerate your cabling system approvals

Mar11 Rev E

HighBand 25. TrueNet Category 6 Solutions

s (with up to 250 MHz Patent pending Page 1 of 9

Transcription:

White Paper 02. Juli 2002 Andreas Clauser Hauptsitz Binzstrasse 31 CH-8622 Wetzikon Tel +41 1 933 8375 Fax +41 1 930 49 41 Internet www.rdm.com Do you know if your Cat. 6 patch cord has been tested according to standards? Unfortunately, reality shows that many of the alleged Cat. 6 patch cords do not fulfil the values laid down in standards! It is common knowledge that today most of the installations are only measured as permanent links. But will your installations still yield the required performance, once the patch cords are connected? Is it enough when the stranded cable complies with the standard? How can you make sure yours is a good patch cord? This article will give you the answers to all these important questions when choosing patch cords. It also presents today s standards of patch cords and stranded cables and discusses their differences. Furthermore, it clearly describes how to proceedin order to find guaranteed top-grade patch cords. Summary Cat. 6 patch cords are specified in the standards PrEN 50173, ISO/IEC 11801 2 nd Edition and ANSI/TIA/EIA-568-B.2.1. They include defined minimum values for near-end crosstalk and return loss. Due to its consistent organisation the TIA/EIA-568-B.2.1, Draft 9 should be used as reference for the assessment of flex cables and patch cords. The draft of ISO/IEC 11801 2 nd Edition from April 2001 contains mistakes and should not serve as reference in the assessment of flex cables. CENELEC with PrEN 50173 has not yet defined a required near-end crosstalk value for Cat. 6 patch cords. There is only one way to make absolutely sure that your patch cord fulfils the standard, namely to ask the manufacturer for the test record from patch cord production. Detailed specifications The Cat. 6 patch cords are specified in the standards PrEN 50173, ISO/IEC 11801 2 nd Edition and ANSI/TIA/EIA-568-B.2.1. These standards issue identical required values for return loss. ISO/IEC White Paper/ Standards Seite 1 / 5

and TIA/EIA issue the same required values for near-end crosstalk, whereas CENELEC has not yet determined values required for Cat. 6 patch cord near-end crosstalk (as of April 2002). The new cabling standards specify patch cords of up to 20 metres. The frequency range is specified from 1 to 250 MHz. The near-end crosstalk values vary depending on the patch cord's length. By contrast the return loss values were specified independent of the patch cord's length.. Table 1: Standards for patch cords and flexible cables Document Name Title ANSI/TIA/EIA-568-B.2.1 Addendum No. 1 to TIA/EIA-568-B.2, "Transmission Performance Specifications for 4-Pair 100 Category 6 Cabling", November 2001 Draft 10 Preliminary ISO/IEC 11801 2 nd edition 2 nd CD, IT-Cabling for customer premises, April 2001 PrEN 50173 Information technology-generic cabling systems, August 2001 The standards give identical values for flex cables. There is, however, a small but significant difference: ISO/IEC 11801 specifies return loss between 4 and 250 MHz whereas ANSI/TIA/EIA set their frequency range at between 1 and 250 MHz. In reality, the return loss as specified in ISO/IEC 11801 2nd leads to the situation where the cable fulfils the standard for a flexible cable of 100 m, but the patch cords of between 5 and 10 m no longer fulfil the standard. Graph 1 Graph 2 RL S-STP flex cable 100m a RL S-STP flex cable 5m 7 7 6 6 Limit C6 flex cable 1,2 100m side a 3,6 100m side a 4,5 100m side a 7,8 100m side a Limite C6 Cord 1,2 5m 3,6 5m 4,5 5m 7,8 5m Limit C6 flex cable White Paper/ Standards Seite 2 / 5

Graph 1 shows the measurement of a 100 m flexible cable, which fulfils the specifications according to ISO/IEC. It only falls short of the limit below 4 MHz. Then, 20 metres of the cable were cut off and it was tested for the patch cords' limits as specified by ISO/IEC. To exclude any influence from the connector and the connector's termination the cable was measured separately. The result is shown below, in Graph 3: the patch cord fails. It is the same with patch cords of 10 metres (Graph 4). The patch cords of 5 metres only just about fulfil the ISO/IEC requirements again (Graph 2). Graph 3 Graph 4 RL S-STP flex cable 20m RL S-STP flex cable 10m 7 6 6 Magnitude [MHz] Limite Cord 1,2 20m 3,6 20m 4,5 20m 7,8 20m Limit (db) Limite C6 Cord 1,2 10m 3,6 m 4,5 m 7,8 m Limit flex cable The results are summarised in Table 2. They show that up to 3.7 db of reserve can be lost from a flexible cable to a patch cord of 20 metres due to the fact that ISO/IEC only start measuring cables from 4 MHz upward. Table 2: ISO/IEC 11801 2nd Edition Standard for 100 m flex cable Standard for patch cord up to 20 m Frequency range 4... 250 MHz 1... 250 MHz Length 100 m 20 m 10 m 5 m Frequency of smallest reserve 1.4 db 4.6 MHz -2.3 db 2.0 MHz -1.4 db 4.4 MHz 0.15 db 8.9 MHz Result PASS FAIL FAIL PASS The draft of ISO/IEC 11801 2 nd Edition from April 2001 contains mistakes and should not serve as reference in the assessment of flex cables. White Paper/ Standards Seite 3 / 5

In a second step the measuring results were compared with the specifications of ANSI/TIA/EIA 568- B2.-1 Draft 10 of November 2001. The results are summarised in Table 3. Table 3: ANSI/TIA/EIA 568-B.2-1 Draft 10 Standard for 100 m flex cable Standard for patch cord up to 20 m Frequency range 1... 250 MHz 1... 250 MHz Length 100 m 20 m 10 m 5 m Frequency of smallest reserve -2.0 db 1.5 MHz -2.3 db 2.0 MHz -1.4 db 4.4 0.15 db 8.9 Result FAIL FAIL FAIL PASS In TIA/EIA 568-B.2-1 Draft 10 the return loss specifications for flex cables are consistent with the limits for patch cords, both starting at 1 MHz. The reserves for the limits of a 100 m flex cable and of a 20 m patch cord also match. Furthermore, it is shown that the frequency of the worst value with reference to the limit is doubled when the patch cord's length is cut in half. This effect is caused by standing waves in the cable. Due to its consistent organisation the TIA/EIA-568-B.2.1, Draft 9 should be used as reference for the assessment of flex cables and patch cords. Reality has shown that only a few of the alleged Cat. 6 patch cords actually fulfil the values stipulated by the standards. How can you make absolutely sure that your patch cord complies with the TIA/EIA or ISO/IEC standards? It is only possible if the patch cord production is subject to a test system. The parameters near-end crosstalk and return loss must be fulfilled in compliance with ANSI/TIA/EIA-568- B.2.1 (as of Draft 9) or ISO/IEC 11801 2 nd Edition. How can a customer make sure such a test system was not only implemented by marketing but also in production? Here the only way is to ask for the manufacturer's test record of the patch cord production, which should list the measured values and the standards applied. Ask the manufacturer for the test record of the patch cord production. White Paper/ Standards Seite 4 / 5

White Paper/ Standards Seite 5 / 5