Pendant Downlight Aircraft Cable Uplight Aircraft Cable Downlight Hinge Mount Fixed Mount LIGHT SOURCE OPTICS 6W/FT, 12W/FT RGB and RGB+W RGBWWA CCT LUMEN MAINTENANCE ELECTRICAL CONTROL PHYSICAL CERTIFICATION RGB RGB+W RGBWWA 75,000 hrs L70 INPUT VOLTAGE POWER SUPPLY TOTAL POWER CONSUMPTION DMX READY DIMENSIONS (HEIGHT X WIDTH) HOUSING LENS OPERATING TEMPERATURES RoHS COMPLIANT 120V or 277V Remote Power Supply FIXTURE WATTAGE 6.0 W/ft 12.0 W/ft With Flat Lens: X With White Direct View Dome Lens: 1-3/" X TOTAL POWER CONSUMPTION 6.0 W/ft 12.0 W/ft Aluminum extrusion with molded end caps, powder-coated finish, White Flat Clear Acrylic Lens is standard Optional "Flat White Acrylic Lens" is available with 120 optics only (not recommended for RGBWWA products). Allows for smooth light distribution, but does not remove diode images. Optional "White Direct View Dome Lens" (DV) for direct view applications is available with 120 optics only (not recommended for RGBWWA products). The Direct View Lens option creates a crisp white illuminattion and eliminates all diode images. -25 C to 40 C ETL and cetl Listed for Dry Location WARRANTY 5 Year Limited Warranty 5 Year Limited All PILOT products are tested to IES LM-79 standards Page 1 of
PLA PREFIX PLA Pilot Architectural Series WATTAGE WATTS /FT LED COLOR 6 RGB 30 = 120 = 6W RGB Tri-Chromatic red, green, blue 12 RGB+W 30 = 120 = 12W RGB+W Tri-Chromatic red, green, blue + 40K white ORDERING INFORMATION OPTICS MOUNTING FIXTURE LENGTH 30 X 60 120 X 120 30 X 60 120 X 120 SINGLE FIXTURE MOUNTING OPTIONS HM = Hinge FM = Fixed ACSD = Aircraft Cable, Downlight ACSU = Aircraft Cable, Uplight 12 RGBWWA 120 = 120 X 120 PNSD = Pendant, Downlight RGBWWA red, green, blue (discreet), 4000K white, 6500K white & amber MULTIPLE FIXTURE RUN MOUNTING OPTIONS ACMD = Aircraft Cable, Downlight ACMU = Aircraft Cable, Uplight All Color Changing products require a DMX programmer for proper mixing. Must order separately. One LPT is required for field re-addressing of factory DMX settings. See below. SINGLE FIXTURES 12" 24" 36" 4" FOR MULTIPLE FIXTURE RUNS PLEASE RUN LENGTH IN FEET VOLTAGE/ WIRING METHOD REM1 = 120V Remote Power REM2 = 277V Remote Power Power supplies must be ordered separately. See below. CONTROL OPTIONS FINISH OPTIONS RGB & RGB+W Control Options DMXFX = Resolution per power supply RGBWWA Control Options DMXFX = Power Supply Resolution DMXFT = Foot-by-Foot Resolution DMXSY = System Resolution DMX Controls are required. Order separately Contact factory for Insight's Wireless Option W = Semi-Gloss White Contact factory for additional finishes WL = Flat White Diffusing Lens (Available with 120 optics only and it is not recommended with RGBWWA products) DV = Direct View Dome Lens For Direct View Applications (Available with 120 optics only and it is not recommended with RGBWWA products) Contact factory for MRI applications CATALOG NUMBER POWER SUPPLIES (SEE DIMENSIONS ON PAGE 7) RGB AND RGB+W (CONSTANT VOLTAGE) DESCRIPTION C1/RGB/120V C1/RGB/277V CATALOG NUMBER C1/DAT/120V C1/DAT/277V (1)-100W POWER SUPPLY, 120V FOR RGB,RGB+W, ACTIVE WHITE (1)-100W POWER SUPPLY, 277V FOR RGB,RGB+W, ACTIVE WHITE (1)-100W POWER/DATA SUPPLY, 120V FOR RGBWWA (1)-100W POWER/DATA SUPPLY, 277V FOR RGBWWA RGBWWA (CONSTANT VOLTAGE) DESCRIPTION C1/RGB & C1/DAT REMOTE POWER SUPPLIES ARE LIMITED TO THE FOLLOWING: 6W/FT: 12' or less of fixtures per power supply 12W/FT: 6' or less of fixtures per power supply REMOTE POWER SUPPLY DISTANCE NOT TO EXCEED 25 FEET FROM REMOTE POWER SUPPLY TO END OF FIXTURE RUN. PL-120V PL-277V 120V PLENUM RATED THERMAL PROTECTOR 277V PLENUM RATED THERMAL PROTECTOR POWER SUPPLY OPTIONS If required, plenum rated cabling to be suppled by others CATALOG NUMBER EXAMPLE: C1 / PWR / CC / 24" / 10W / PL-120V CATALOG NUMBER LPT CDS-A DMX PROGRAMMING KIT REQUIRED FOR ALL INSTALLATIONS DMX PROGRAMMING TOOL One LPT is required for field re-addressing of factory DMX settings. DESCRIPTION DMX DISTRIBUTION KIT ONLY (4 OUTPUTS) CDS-A consists of four outputs. Each output accommodates up to 32 fixtures in INT/REM wiring methods and unlimted fixtures in ACV wiring method. Four terminators are included for use as required. Page 2 of
HINGE MOUNT - HM Dim A 24-1/2" 36-1/2" 4-1/2" Dim B 6" to 12" 9" to 33" 9" to 45" 1 5" 3" 4 1 4 1" WITH HINGE MOUNT 65 ROTATION 1 3" 1 5" 1 7" WITH HINGE MOUNT 65 ROTATION DIM 'C' 2x clearance holes for 2x clearance holes for # mounting hardware (by others, per hinge) 65 65 5" 1 1" 4 FIXED MOUNT - FM 2" FRONT VIEW 1" Ø 1/" 1 5/" 4 FT - FLYING LEADS - TYP. /2 2" FRONT VIEW 1 3/" 1 Ø 1/" 1 5/" 4 FT - FLYING LEADS - TYP. /2 1/" 1/4" 2XØ 1/4" FOR # MOUNTING FASTENERS (BY OTHERS) Dim A 24-1/2" 36-1/2" 4-1/2" Dim B 6" to 12" 12" to 24" 24" to 36" 1" MOUNT BRACKET DETAILS Page 3 of
PENDANT, SINGLE FIXTURE, DOWNLIGHT - PNSD 3 4 " 6" Min. 4" Max. 4" DIA. POWER FEED 1 5 " DIM. A 1 3" 6" Min. 4" Max. 4" Dia. Power Feed 1 5 " Dim A 24-1/2" 36-1/2" 4-1/2" Dim B 12-1/4" 1-1/4" 24-1/4" AIRCRAFT CABLE, SINGLE FIXTURE, DOWNLIGHT - ACSD CTR. TO CTR MOUNTING LENGTH 6ʺ MIN. CTR. TO CTR MOUNTING 1-3/" LENGTH 6ʺ MIN. Dim A 24-1/2" 36-1/2" 4-1/2" Dim B 9-1/2" to 1-1/2" 15-1/2" to 30-1/2" 9" to 45" Page 4 of
AIRCRAFT CABLE, MULTIPLE FIXTURE RUN, DOWNLIGHT - ACMD 12 INCH - FLYING LEADS, TYP. 3" 3" 6" MIN. 4" DIA POWER FEED 2-1/2" DIA NON-POWER FEED 12 INCH - FLYING LEADS, TYP. 3" 3" 6" MIN. 4" DIA POWER FEED 2-1/2" DIA NON-POWER FEED 1-3/" Dim A 24-1/2" 36-1/2" 4-1/2" Dim B 2 33-5/" 45-5/" Page 5 of
AIRCRAFT CABLE, SINGLE FIXTURE, UPLIGHT - ACSU Dim A 26" 3" 50" Dim B 25" 37" 49" ctr. to ctr. mounting Specify length 6" min. Specify length 6" min. 1-3/" AIRCRAFT CABLE, MULTIPLE FIXTURE RUN, UPLIGHT - ACMU 12 INCH - FLYING LEADS, TYP. Specify length 6" min. 4" Dia. Power Feed 2-1/2" Dia. Non-Power Feed Dim A 26" 3" 50" Dim B 25-1/2" 37-1/2" 49-1/2" Page 6 of
CONTRA PWR, DIM, DAT DIMENSIONS 2 1/4" 5" 7 1/2" THERMAL PROTECTOR PLENUM RATED OPTION 14 1/2" 12 7/" SIDE VIEW 3 BACK VIEW FRONT VIEW ( PLENUM ) LPT DMX PROGRAMMING KIT DIMENSIONS 1.625 11.500 9.500 7.000 5.500 Page 7 of
DMX LINE NOTES: 1 FIXTURE PER CONTRA, TYPICAL. 2 OUTPUTS PER CONTRA, MAX. MULTIPLE CONTRA'S, CONTACT FACTORY. WIRING DETAILS TYPICAL -DMX, WIRING CONCEPT DC REMOTE-flying lead WARNING: REMOVAL OF END CAP ON THIS FIXTURE VOIDS ALL WARRANTIES! 120-277 AC LINE BELDEN 941 OR EQUIVALENT CABLE, IF APPLICABLE 120 - AC LINE CONTRA ( SEE DMX LINE NOTES ) CONTROL SOURCE ( 4 FT LEAD PROVIDED TYP. ) LUMINAIRE MAX WIRE DISTANCE - RGB / RGBW / RGBWWA / AWH 22 AWG DMX LINE NOTES: WARNING: 1 FIXTURE PER CONTRA, TYPICAL. 2 OUTPUTS WARNING: PER CONTRA, MAX. MULTIPLE CONTRA'S, CONTACT FACTORY. 6WATTS/FT 12WATTS/FT 15 FT AWAY 15 FT AWAY WIRING DETAILS TYPICAL -DMX, ACV WIRING CONCEPT CAUTION: THIS IS AN ELECTRONIC DEVICE. CARE MUST BE TAKEN DURING STORAGE AND HANDLING. STORE IN CLEAN, COOL, AND DRY LOCATION. ELECTROSTATIC DISCHARGE (ESD) CAN HARM THIS PRODUCT. AVOID STATIC DISCHARGE WHILE HANDLING THIS PRODUCT. CAUTION: ALL ELECTRICAL CONNECTIONS TO BE MADE BY A LICENSED ELECTRICIAN. DC REMOTE-flying lead CONTRA DATA CHAIN MAKE SURE ALL ELECTRICAL POWER IS OFF WHEN INSTALLING LUMINAIRES. NOTICE: SECONDARY CONNECTIONS SHALL BE INSIGHT LIGHTING IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY MADE IN ACCORDANCE OF THE BUILDING TO SUPPORT THE LUMINAIRE. ADDITIONAL BACKING WITH NEC ARTICLE 725. MAY BE REQUIRED. 120-277 AC LINE 5/1/15 WARNING: REMOVAL OF END CAP ON THIS FIXTURE VOIDS ALL WARRANTIES! 1 OF 1 BELDEN 941 OR EQUIVALENT CABLE, IF APPLICABLE CONTRA ( SEE DMX LINE NOTES ) 120 - AC LINE CONTROL SOURCE CONTRA ( SEE LINE NOTES ) 120-277 AC LINE IF APPLICABLE, MULTIPLE FIXTURE, 24 AWG DATA PAIR (BY OTHERS) CAN CONNECT DATA TO MULTIPLE CONTRA'S ( 4 FT LEAD PROVIDED TYP. ) LUMINAIRE ( 4 FT LEAD PROVIDED TYP. ) LUMINAIRE MAX WIRE DISTANCE - RGB / RGBW / RGBWWA / AWH 6WATTS/FT 12WATTS/FT 22 AWG 15 FT AWAY 15 FT AWAY CAUTION: THIS IS AN ELECTRONIC DEVICE. CARE MUST BE TAKEN DURING STORAGE AND HANDLING. STORE IN CLEAN, COOL, AND DRY LOCATION. ELECTROSTATIC DISCHARGE (ESD) CAN HARM THIS PRODUCT. AVOID STATIC DISCHARGE WHILE HANDLING THIS PRODUCT. 5/1/15 WARNING: ALL ELECTRICAL CONNECTIONS TO BE MADE BY A LICENSED ELECTRICIAN. WARNING: CAUTION: MAKE SURE ALL ELECTRICAL POWER IS OFF WHEN INSTALLING LUMINAIRES. INSIGHT LIGHTING IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THE BUILDING TO SUPPORT THE LUMINAIRE. ADDITIONAL BACKING Insight Lighting. Specifications are MAY subject BE REQUIRED. to change without notice. NOTICE: SECONDARY CONNECTIONS SHALL BE MADE IN ACCORDANCE WITH NEC ARTICLE 725. 1 OF 1 Page of