TT N TENG TESTING R& TTE TEST REPORT For Electric Skateboard Surfwheel R1 Trademark: Surfwheel Test Report Number: TT1605230089RT Issued Date: June 02, 2016 Issued for: Koofy Development Limited Unit 220 2/F, Enterprise Place, NO.5 Science Park West venue, Science Park, Shatin, N.T., HK TEL: +86 75527724522 FX: +8675527724533 Note: This report shall not be reproduced except in full, without the written approval of Shenzhen n-teng Testing Service Co., Ltd. This document may be altered or revised by Shenzhen n-teng Testing Service Co., Ltd. personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample.
------ TT N TENG TESTING 1 GENERL INFORMTION Shenzhen n-teng Testing Service Co., Ltd Report No.: TT1605230089RT pplicant Koofy Development Limited ddress Unit 220, 2/F, Enterprise Place, NO.5 Science Park West venue, Science Park, Shatin, N.T., HK Manufacture Huizhou Tianchang Industrial Co. Ltd. ddress No.2, Xingde & Xingye Rd, Dongjiang Hi-tech Zone, Zhongkai Hi-tech Zone, Huizhou, Guangdong, China Equipment under Test (EUT) Name: Model No.: EUT Power Supply: Standards: ITest Result: Electric Skateboard Surfwheel R 1 DC 59V (Recharge Voltage: DC 67.2V, 1.5) ETSI EN 301 489-3: 2002 V1.4.1, ETSI EN 301 489-1 :2008 V1.8.1 I PSS In the configuration tested, the EUT detailed in this report complied with the standards specified above. refer to section 2 of this report for further details. Please The other tests (e.g. Low Voltage Directive 2014/30/EU) required in R&TIE Directive2014/53/EU were not included in the report, only part tests related to RF were performed and reported in this report. Hence to clarify compliance with R&TTE directive 99/5/EC shall comply with the other essential required tests additionally. I Tested By: t MI(/& ~'I'f- /~ Nico Liang Date: ~J~u"n~e~Oul~._2~Ol~6~ Check By: ~~~~~~~~ Date : ---IJll,luwnwei..lil.0... 2,...21ir.10"'1u.61..-_ dd: Room1502, Liutang Building, Baomin 2nd Road, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China. Page 2 of 23
2 Test Summary Shenzhen n-teng Testing Service Co., Ltd Electromagnetic Compatibility (EMC) Part The EUT belong to Type I in table 1 and class 3 in table 3 (refer to nnex B) of EN301489-3:2002. Test Test Requirement Test Method Class / Severity Remark Result Radiated Emission, 30MHz to 6 GHz EN 301489-3:2002 V 1.4.1 clause 7.1 EN301489-1: 2008 V1.8.1.clause 8.2, EN55016 Class B Table 3, 4 Test Rx only PSS Conducted emission (150K to 30MHz) EN 301489-3:2002 V 1.4.1 clause 7.2 EN 301489-1: 2008 V1.8.1.clause 8.3/ 8.4/ 8.7 EN 55022 Class B Test both Rx & Tx together. (worst case) N/ Electrostatic Discharge EN 301489-3:2002 V 1.4.1 clause 7.2 EN 301489-1/9.3 EN 61000-4-2 4kV, Contact 8kV. ir Test Tx & Rx together PSS Radiated Immunity, 80MHz to 1GHz & 1.4GHz to 2.7GHz EN301489-3:2002 V 1.4.1 clause 7.2 EN 301489-1/9.2 EN 61000-4-3 3V/m, 80%, 1KHz,.M. Test Tx & Rx together PSS EFT (Electrical Fast Transients) on C EN 301489-3:2002 V 1.4.1 clause 7.2 EN 301489-1/9.4 EN 61000-4-4 Table 3 row 4 Test Tx & Rx together N/ Surge Immunity on C EN 301489-3:2002 V 1.4.1 clause 7.2 EN 301489-1/9.8 EN 61000-4-5 Table 3 row 8 Test Tx & Rx together N/ Injected Currents 150kHz to 80MHz EN 301489-3:2002 V 1.4.1 clause 7.2 EN 301489-1/9.5 EN 61000-4-6 Table 3 row 5 Test Tx & Rx together N/ Voltage Dips and Interruptions on C EN 301489-3:2002 V 1.4.1 clause 7.2 EN 301489-1/9.7 EN 61000-4-11 Table 3 row 7 Test Tx & Rx together N/ Tx: In this whole report Tx (or tx) means Transmitter. Rx: In this whole report Rx (or rx) means Receiver. Page 3 of 23
3 Contents Page 1 GENERL INFORMTION... 2 2 TEST SUMMRY... 3 3 CONTENTS... 4 4 GENERL INFORMTION... 5 4.1 CLIENT INFORMTION... 5 4.2 DETILS OF E.U.T... 5 4.3 DESCRIPTION OF SUPPORT UNITS... 5 4.4 STNDRDS PPLICBLE FOR TESTING... 5 4.5 TEST LOCTION... 6 4.6 DEVITION FROM STNDRDS... 6 4.7 OTHER INFORMTION REQUESTED BY THE CUSTOMER... 6 4.8 MONITORING OF EUT FOR THE IMMUNITY TEST... 6 4.9 MODEL DIFFERENCE... 6 5 EMC REQUIREMENTS SPECIFICTION IN EN 301489-3... 7 5.1 EMI (EMISSION)... 8 5.1.1 Radiated Emission... 8 5.1.2 Conducted Emission... 11 5.1.3 Harmonics Test Results... 12 5.1.4 Flicker Test Results... 12 5.2 IMMUNITY... 13 5.2.1 ESD... 15 5.2.2 Radiated Immunity... 16 5.2.3 Electrical Fast Transients (EFT)... 17 5.2.4 RF Common Mode 0.15MHz to 80MHz... 18 6 PPENDIX : INSTRUMENTS USED DURING TEST... 19 6 EUT PHOTOGRPHS... 21 Page 4 of 23
4 General Information 4.1 Client Information pplicant: ddress of pplicant: 4.2 Details of E.U.T Koofy Development Limited Unit 220, 2/F, Enterprise Place, No.5 Science Park West venue, Science Park, Shatin, N.T., HK EUT Power Supply: DC 59V (Recharge Voltage: DC 67.2V,1.5) 4.3 Description of Support Units The EUT has been tested as an independent unit. 4.4 Standards pplicable for Testing The customer requested (R&TTE) EMC part tests for R/C CR. The standards used were EN 301 489-3 V1.4.1 (2002-08) Table 1 : Tests Carried Out Under EN301489-3 V1.4.1 (2002-08) EMI TEST ITEM TEST METHOD Clause 7.1 Radiated Emission EN301489-1: 2008 V1.8.1.clause 8.2, EN55016 Conducted Emission EN301489-1: 2008 V1.8.1.clause 8.3/ 8.4/ 8.7, EN55022 Harmonic Current EN301489-1: 2008 V1.8.1.clause 8.5 EN 61000-3-2 Voltage Fluctuation & Flicker EN301489-1: 2008 V1.8.1.clause 8.6 EN 61000-3-3 EMS TEST ITEM TEST METHOD Clause 7.2 RF EM fields (RI) EN301489-1: 2008 V1.8.1.clause 9.2, EN 61000-4-3 Electrostatic Discharge (ESD) EN301489-1: 2008 V1.8.1. clause 9.3, EN 61000-4-2 Fast transients (EFT) EN301489-1: 2008 V1.8.1.clause 9.4, EN 61000-4-4: RF Common Mode (CI) EN301489-1: 2008 V1.8.1.clause 9.5, EN 61000-4-6 Transient & Surge in Vehicular EN301489-1: 2008 V1.8.1.clause 9.6, ISO7637-1/-2 Voltage dips & Interruption EN301489-1: 2008 V1.8.1.clause 9.7, EN 61000-4-11 Surge EN301489-1: 2008 V1.8.1.clause 9.8, EN 61000-4-5 : Indicates that the test was not applicable, since the EUT is powered by DC input. : Indicates that the test was applicable. Page 5 of 23
4.5 Test Location ll tests were performed at: NTEK Testing Technology Co., Ltd. ddress: Fenda Science Park, Sanwei Community, Xixiang Street, Bao'an District, Shenzhen, China 4.6 Deviation from Standards None. 4.7 Other Information Requested by the Customer None. 4.8 Monitoring of EUT for the Immunity Test Visual: Monitored the work status of the EUT. udio: Monitored the sound of the EUT. 4.9 Model difference Page 6 of 23
5 EMC Requirements Specification in EN 301489-3 Type of SRD Equipment in EN301489-3, sub clause 4.1 table 1 Equipment Type I II III Technical nature of the primary function Transfer of messages (digital or analogue signals) Transfer of audio (speech or music) Others Classification of SRD Equipment in EN301489-3, sub clause 6.1 table 3 Class of SRD Equipment 1 2 3 Risk assessment of Rx performance Highly reliable SRD communication media; e.g. serving human life inherent system (may result in a physical risk to a person) Medium reliable SRD communication media e.g. causing inconvenience to persons, which cannot simply overcome by other means Standard reliable SRD communication media e.g. causing inconvenience to persons, which can simply overcome by other means Remark: The EUT belong to Type I, class 3. Page 7 of 23
5.1 EMI (Emission) 5.1.1 Radiated Emission Test Method: EUT Operation: EN301489-1 clause 8.2.2 (EN55016-2-3) Running(Test both Rx & Tx together). mbient: Temp.: 25 C Humid.: 45% Press.: 1050 mbar Status: Compliance test in keeping running mode. Receive setup: Frequency range (MHz) Detector RBW VBW 30-1000 Quasi-peak 120KHz 300KHz bove 1000 Peak 1MHz 3MHz Test Limit Frequency Limit(3m) Remark Test Procedure: 30MHz-230MHz 40dBuv/m QP value 230MHz-1GHz 47dBuv/m QP value 1GHz-3GHz 3GHz-6GHz 50dBuv/m 70dBuv/m 54dBuv/m 74dBuv/m verage value PK value verage value PK value 1. The EUT is placed on a turntable, which is 0.8m above ground plane. 2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission level. 3. EUT is set 3m away from the receiving antenna, which is moved from 1m to 4m to find out the maximum emissions. 4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance. 5. nd also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. 6. Repeat above procedures until the measurements for all frequencies are complete. Equipment Used: Please refer to the section 6. Page 8 of 23
Test Configuration: Below 1GHz bove 1GHz Page 9 of 23
5.1.1.1 Measurement Record Uncertainty: 6dB Rx running mode below 1GHz Cable ntenna Preamp Read Over Frequency Level Limit Line Loss Factor Factor Level Limit (MHz) (dbuv/m) (dbuv/m) (db) (db/m) (db) (dbuv) (db) Polarity 31.29 0.65 12.32 25.76 45.21 31.08 40.00-8.92 Vertical 53.13 0.69 13.94 25.75 32.15 23.75 40.00-16.25 Vertical 99.88 1.20 14.56 25.65 36.13 24.69 40.00-15.31 Vertical 139.85 1.52 9.43 25.67 45.22 29.88 40.00-10.12 Vertical 180.02 1.54 14.56 25.68 38.73 30.36 40.00-9.64 Vertical 250.30 1.20 14.32 25.69 36.24 21.75 4000-18.25 Vertical 30.64 0.65 11.56 25.78 40.12 24.84 40.00-15.16 Horizontal 96.10 1.16 11.54 25.70 39.36 23.43 40.00-16.57 Horizontal 139.85 1.52 10.22 25.87 45.33 29.74 40.00-10.26 Horizontal 170.19 1.68 10.56 25.67 41.16 30.14 40.00-9.86 Horizontal 210.05 1.98 11.54 25.82 45.61 29.44 40.00-10.56 Horizontal 250.30 1.97 13.64 25.76 38.24 28.76 40.00-11.24 Horizontal Rx running mode above 1GHz Peak measurement Cable ntenna Preamp Read Limit Over Frequency Level Loss Factor Factor Level Line Limit (MHz) (dbuv/m) (db) (db/m) (db) (dbuv) (dbuv/m) (db) Polarity 1290 4.62 26.45 38.72 54.57 43.18 70.00-26.82 Vertical 2155 5.62 29.32 38.77 58.12 51.77 70.00-18.23 Vertical 4870 10.52 34.36 39.48 47.14 48.23 74.00-25.77 Vertical 1730 5.32 27.96 39.52 60.64 51.38 70.00-18.62 Horizontal 2170 5.62 29.24 38.98 51.46 48.45 70.00-21.55 Horizontal 4510 8.86 33.92 39.92 46.34 47.88 74.00-26.12 Horizontal verage measurement Page 10 of 23
Frequency (MHz) Cable Loss (db) ntenna Factor (db/m) Preamp Factor (db) Read Level (dbuv) Level (dbuv/m) Limit Line (dbuv/m) Over Limit (db) Polarity 1290 4.76 26.43 39.62 42.08 31.78 50.00-18.22 Vertical 2155 5.62 29.26 39.12 46.80 42.46 50.00-7.54 Vertical 4870 10.42 34.35 39.76 36.04 39.46 54.00-14.54 Vertical 1730 5.36 27.92 39.55 46.09 38.88 50.00-11.12 Horizontal 2170 5.62 29.21 38.87 39.05 33.85 50.00-16.15 Horizontal 4510 8.89 33.87 39.92 33.97 34.76 54.00-19.24 Horizontal Remark: The EUT was tested at 3m in field chamber. 5.1.2 Conducted Emission Test Method: EN 301489-1 clause 8.4.2 (EN 55022) Detector: Peak for pre-scan (9kHz Resolution Bandwidth) Quasi-Peak if maximised peak within 6dB of Quasi-Peak limit EUT Operation: Running(Test both Rx & Tx together). mbient: Temp.: 25 C, Humid.: 63% Press.: 1050 mbar Status: Test Procedure: Equipment Used: Compliance test in keeping running mode. Scan from 0.15M to 30MHz, find the maximum radiation frequency to measure. Refer to section 5 for details. Test Configuration: Test Results N/ Page 11 of 23
5.1.3 Harmonics Test Results Test Requirement: EN 301 489-3: EN 61000-3-2 Test Method: N/: See Remark Below Remark: There is no need for Harmonics test to be performed on this product (rated power is less than 75W) in accordance with EN 61000-3-2. For further details, please refer to Clause 7, Note 1 of EN 61000-3-2 which states:- For the following categories of equipment limits are not specified in this edition of the standard. Note 1: Equipment with a rated power of 75W or less, other than lighting equipment. 5.1.4 Flicker Test Results Test Requirement: EN 301 489-1: EN 61000-3-3 Test Method: N/: See remark below Remark: There is no need for Flicker test to be performed on this product in accordance with EN 61000-3-3. For further details, please refer to Clause 6.1 of EN 61000-3-3 which states:- Tests need not be made on equipment which is unlikely to produce significant voltage fluctuations or flicker. It may be necessary to determine, by examination of the circuit diagram and the specification of the equipment and by a short function test, whether significant voltage fluctuations or flicker are likely to be produced. Page 12 of 23
5.2 Immunity Performance Criteria of EN301489-3, sub clause 6.3 table 4. Class 1 SRD Equipment Criteria During Test fter Test B Operated as intended, Operated as intended, No loss of function, No loss of function, For equipment Type II the communication link shall For equipment Type II the minimum be maintained. performance shall be 12dB SIND, No Degradation of performance, No unintentional responses. No loss of data or user programmable functions May be loss of function (one or more) Operated as intended, No unintentional responses Loss functions shall be self- recoverable, No Degradation of performance, No loss of data or user programmable functions Class 2 SRD Equipment Criteria During Test fter Test B Operated as intended, No loss of function, For equipment Type II the minimum performance shall be 6dB SIND, No unintentional responses. May be loss of function (one or more), No unintentional responses Operated as intended, No loss of function, For equipment Type II the communication link shall be maintained. No Degradation of performance, No loss of data or user programmable functions Operate as intended, Loss functions shall be self- recoverable, No Degradation of performance, No loss of data or user programmable functions Class 3 SRD Equipment Criteria During Test fter Test & B May be loss of function (one or more), No unintentional respond. Operate as intended, for equipment Type II the communication link may be lost, but shall be recoverable by user. No Degradation of performance. Loss functions shall be self- recoverable. Page 13 of 23
Remark: The EUT belonged to class 3. Shenzhen n-teng Testing Service Co., Ltd Page 14 of 23
5.2.1 ESD Test Method: EN301489-1 clause 9.3.2 (EN61000-4-2:1995 +1:1998+2: 2001) EUT Operation: Running(Test both Rx & Tx together). mbient: Temp.: 25 C Humid.: 63% Press.: 1050 mbar Status: 1) Kept Tx & Rx on mode, 2) Kept Tx & Rx idle mode. Test both Rx & Tx together. Test Procedure: Compliance test was performed in mode 1), 2) Equipment Used: Please refer to the section 6. 5.2.1.1 Test Results Direct pplication Test Results Test points: Direct pplication 1. ll insulated enclosure and seams. 2. ll accessible metal parts of the enclosure. Test Results Discharge Level (kv) Pulse No. Test Point Contact Discharge ir Discharge 2, 4, 8 10 for every level 1 N/ 2, 4 10 for every level 2 N/ Indirect pplication Test Results Test points: Indirect pplication for Tx 1. ll sides. Discharge Level (kv) Pulse No. Test Point Horizontal Coupling Test Results Vertical Coupling 2, 4 10 for every level 1 Indirect pplication for Rx Test Results Discharge Level (kv) Pulse No. Test Point Horizontal Coupling Vertical Coupling 2, 4 10 for every level 1 Results : No degradation in the performance of the EUT was observed. No unintentional transmissions were observed. N/: Not applicable (not required by Standard or floor mounted EUT). Page 15 of 23
5.2.2 Radiated Immunity Test Method: EUT Operation: EN301489-1 clause 9.2.2 (EN61000-4-3:2006+1:2008) Running(Test both Rx & Tx together). mbient: Temp.: 25 C Humid.: 45% Press.:1050mBar Status: 1) Kept Tx & Rx on mode, 2) Kept Tx & Rx idle mode. Test both Rx & Tx together. Test Procedure: Compliance test were performed in mode 1), 2) Equipment Used: Please refer to the section 6. 5.2.2.1 Test Results Frequency Level Modulation EUT Face ntenna Polaxis V Front H Result / Observations Back V H 80MHz-1GHz, 1.4GHz to 2.7G 3V/m 1kHz, 80% mp. Mod, 1% increment Dwell time:3seconds Left Right V H V H Top V H Under V H Remarks: : No degradation in the performance of the E.U.T. was observed. No unintentional transmissions were observed. Page 16 of 23
5.2.3 Electrical Fast Transients (EFT) Test Method: EN 301489-1 clause 9.4.2 (EN 61000-4-4:2004) Test Level: Polarity: Repetition Frequency: Burst Duration: Test Duration: EUT Operation: 0.5, 1.0kV on C Positive & Negative 5kHz 300ms 2 minute per level & polarity Running(Test both Rx & Tx together). mbient: Temp.: 25 C Humid.: 45% Press.: 1050mBar Status: 1) Keep the RX unit in running mode. 2) Keep the RX unit in idle mode. Test both Rx & Tx together. Test Procedure: Compliance test were performed in mode 1), 2) Equipment Used: Refer to section 5 for details. 5.2.3.1 Test Results Lead under Test Level ( kv) Coupling Direct/Clamp EUT operating mode Observations (Performance Criterion) Live 1.0 Direct ll mode No loss of performance was observed () Neutral 1.0 Direct ll mode () Live, Neutral 1.0 Direct ll mode () Page 17 of 23
5.2.4 RF Common Mode 0.15MHz to 80MHz Test Method: EN301489-1 clause 9.5.2 (EN61000-4-6:2007) Test level: 3V rms on C Ports (unmodulated emf into 150 ) Modulation: 80%, 1kHz mplitude Modulation EUT Operation: Running(Test both Rx & Tx together). mbient: Temp.:25 C Humid.:63% Press.:1050 mbar Status: 1) Keep the RX unit in running mode. 2) Keep the RX unit in idle mode. Test both Rx & Tx together. Test Procedure: Equipment Used: Compliance test was performed in the abovemodes Refer to section 5 for details. 5.2.4.1 Test Results Frequency Line Test Level Modulation Step Size Dwell Time Observation (Performance Criterion) 150kHz to 80MHz 3 Wire C Supply Cable 3Vrm s 80%, 1kHz mp. Mod. 1% 2S No Loss of Function () Page 18 of 23
6 ppendix : Instruments Used during Test RE in Chamber Item Test Equipment Manufacturer Model No. Inventory No. Cal.Date (dd-mm-yy) Cal.Due date (dd-mm-yy) 1 3m Semi-nechoic Chamber ETS-LINDGREN N/ SEL0017 04-10-2016 04-09-2017 2 EMI Test Receiver Rohde & Schwarz ESIB26 SEL0023 04-10-2016 04-09-2017 3 EMI Test software UDIX E3 SEL0050 N/ N/ 4 Coaxial cable SGS N/ SEL0028 04-10-2016 04-09-2017 5 BiConiLog ntenna (26-3000MHz) ETS-LINDGREN 3142C SEL0015 04-10-2016 04-09-2017 6 7 8 9 Pre-amplifier (0.1-1300MHz) Double-ridged horn (1-18GHz) Horn ntenna (18-26GHz) Pre-amplifier (18-26GHz) gilent Technologies 8447D SEL0053 04-10-2016 04-09-2017 ETS-LINDGREN 3117 SEL0006 04-10-2016 04-09-2017 ETS-LINDGREN 3160 SEL0076 04-10-2016 04-09-2017 Rohde & Schwarz FS33-18002 650-30-8P-44 SEL0080 04-10-2016 04-09-2017 10 Band filter mindeon 82346 SEL0094 04-10-2016 04-09-2017 11 ctive.loop ntenna Beijing Daze ZN30900 SEL0097 04-10-2016 04-09-2017 Conducted Emission Item Test Equipment Manufacturer Model No. Inventory No. Cal.Date (dd-mm-yy) Cal.Due date (dd-mm-yy) 1 Shielding Room ZhongYu Electron GB-88 SEL0042 N/ N/ 2 LISN ETS-LINDGREN 3816/2 SEL0021 04-10-2016 04-09-2017 3 8 Line ISN Fischer Custom Communications FCC-TLISN-T8-02 EMC0120 04-10-2016 04-09-2017 Inc. 4 4 Line ISN Fischer Custom Communications FCC-TLISN-T4-02 EMC0121 04-10-2016 04-09-2017 Inc. 5 2 Line ISN Fischer Custom Communications FCC-TLISN-T2-02 EMC0122 04-10-2016 04-09-2017 Inc. 6 EMI Test Receiver Rohde & Schwarz ESCI SEL0022 04-10-2016 04-09-2017 Page 19 of 23
7 Coaxial Cable SGS N/ SEL0024 04-10-2016 04-09-2017 ESD Item Test Equipment Manufacturer Model No. Inventory Cal.Date Cal.Due date No. (dd-mm-yy) (dd-mm-yy) 1 ESD Simulator Thermo MZ-15/EC SEL0012 04-10-2016 04-09-2017 2 ESD Simulator SCHFFNER NSG 438 SEL0035 04-10-2016 04-09-2017 3 ESD Ground Plane SGS(3m*3m) N/ SEL0004 N/ N/ Radiated Immunity Item Test Equipment Manufacturer Model No. Inventory No. Cal.Date (dd-mm-yy) Cal.Due date (dd-mm-yy) 1 3m Semi-nechoic Chamber ETS-LINDGREN N/ SEL0017 04-10-2016 04-09-2017 2 Signal Generator Rohde & Schwarz SML03 SEL0068 04-10-2016 04-09-2017 3 RF mplifier 30M-1GHz mplifier Research 250W1000 SEL0066 04-10-2016 04-09-2017 4 RF mplifier 0.8-3.0GHz mplifier Research 60S1G3 SEL0065 04-10-2016 04-09-2017 5 Power Meter Rohde & Schwarz NRVD SEL0069 04-10-2016 04-09-2017 6 Power Sensor Rohde & Schwarz URV5-Z2 SEL0071 04-10-2016 04-09-2017 7 Power Sensor Rohde & Schwarz URV5-Z2 SEL0072 04-10-2016 04-09-2017 8 Software EMC32 Rohde & Schwarz EMC32-S SEL0082 N/ N/ 9 Log-periodic ntenna mplifier Research T1080 SEL0073 N/ N/ 10 ntenna Tripod mplifier Research TP1000 SEL0074 N/ N/ 11 High Gain Horn ntenna (0.8-5GHz) mplifier Research T4002 SEL0075 N/ N/ EFT, Surge, Voltage dips and Interruption, Power-frequency Magnetic Field Item Test Equipment Manufacturer 1 2 3 EMC Immunity Test System ProPLUS Capacitive Clamp MGNETIC FIELD IMMUNITY LOOP Thermo ELECTRON Thermo ELECTRON Model No. Inventory No. Cal.Date (dd-mm-yy) Cal.Due date (dd-mm-yy) EMCPro Plus SEL0007 04-10-2016 04-09-2017 N/ SEL0008 N/ N/ FCC F-1000-4-8/9/10-L-1M SEL0010 04-10-2016 04-09-2017 Page 20 of 23
7 EUT PHOTOGRPHS Shenzhen n-teng Testing Service Co., Ltd Photo 1 View: [ ] Front [ ] Rear [ ] Right side [ ] Left side [ ] Top [ ] Bottom [ ] Internal Photo 2 View: [ ] Front [ ] Rear [ ] Right side [ ] Left side [ ] Top [ ] Bottom [ ] Internal Page 21 of 23
Photo 3 View: [ ] Front [ ] Rear [ ] Right side [ ] Left side [ ] Top [ ] Bottom [ ] Internal Photo 4 View: [ ] Front [ ] Rear [ ] Right side [ ] Left side [ ] Top [ ] Bottom [ ] Internal Page 22 of 23
Photo 5 Shenzhen n-teng Testing Service Co., Ltd View: [ ] Front [ ] Rear [ ] Right side [ ] Left side [ ] Top [ ] Bottom [ ] Internal --END.-- Page 23 of 23