WU-Minn HCP MEG Initial Data Release: Reference Manual

Similar documents
WU-Minn HCP MEG Initial Data Release: Reference Manual

Brain-Computer Interface (BCI)

Digital SWIR Scanning Laser Doppler Vibrometer

Preparation of the participant. EOG, ECG, HPI coils : what, why and how

Digital SWIR Scanning Laser Doppler Vibrometer

THE BERGEN EEG-fMRI TOOLBOX. Gradient fmri Artifatcs Remover Plugin for EEGLAB 1- INTRODUCTION

Thought Technology Ltd Belgrave Avenue, Montreal, QC H4A 2L8 Canada

Multi echo Multi slice (MEMS) High Performance fmri at CFMRI... 1

ni.com Sensor Measurement Fundamentals Series

BioGraph Infiniti Physiology Suite

"CHARM Access and operational Procedure

The Ultimate Long-term EEG Monitoring System

User Guide EMG. This user guide has been created to educate and inform the reader about doing EMG measurements

Pre-processing of revolution speed data in ArtemiS SUITE 1

Pre-Processing of ERP Data. Peter J. Molfese, Ph.D. Yale University

CHAPTER 3 ECG SIGNAL RECORDING USING LABVIEW

Quick Guide Book of Sending and receiving card

Common Spatial Patterns 2 class BCI V Copyright 2012 g.tec medical engineering GmbH

SedLine Sedation Monitor

Digital 4 Q - Servo amplifier for brushless DC Servo motors (Trapeze)

Lesson 10 Manual Revision BIOPAC Systems, Inc.

Procedures for conducting User QA on the scanner

PITZ Introduction to the Video System

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

Chapter 2 Introduction to

Lab 2: A/D, D/A, and Sampling Theorem

. ImagePRO. ImagePRO-SDI. ImagePRO-HD. ImagePRO TM. Multi-format image processor line

Hall-B Beamline Commissioning Plan for CLAS12

Abstract. Learning Objectives 8/1/2017

Torsional vibration analysis in ArtemiS SUITE 1

Oculomatic Pro. Setup and User Guide. 4/19/ rev

Common Spatial Patterns 3 class BCI V Copyright 2012 g.tec medical engineering GmbH

Tech Note: How to measure additive phase noise of amplifiers using the 7000 Series

OSL Preprocessing Henry Luckhoo. Wednesday, 23 October 13

What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven

Tuesday, Dec 3rd 10:15 to 11:00 IHE Classroom at InfoRAD at RSNA 2002.

MODEL 5493A DTMF MODEM

COPYRIGHT NOVEMBER-1998

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

>Inductive. REFERENCE guide. Proximity

Supplemental Material for Gamma-band Synchronization in the Macaque Hippocampus and Memory Formation

DVB-T2 Transmission System in the GE-06 Plan

IMPORTANT SAFETY INSTRUCTIONS Please read User Guide before using this product. Please keep User Guide for future reference. Please read the cautions

An Introduction to the Spectral Dynamics Rotating Machinery Analysis (RMA) package For PUMA and COUGAR

MNI-BIC MEG Laboratory Manual

Constant Bit Rate for Video Streaming Over Packet Switching Networks

Bit Rate Control for Video Transmission Over Wireless Networks

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

Ensemble QLAB. Stand-Alone, 1-4 Axes Piezo Motion Controller. Control 1 to 4 axes of piezo nanopositioning stages in open- or closed-loop operation

MULTIMEDIA TECHNOLOGIES

Amplification Setup Methods for the Maxprep TM Liquid Handler Technical Manual

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

>Inductive and. REFERENCE guide. Capacitive Sensors

User Guide Slow Cortical Potentials (SCP)

WaveDriver 20 Potentiostat/Galvanostat System

Environmental Controls Laboratory

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor

Heart Rate Variability Preparing Data for Analysis Using AcqKnowledge

4 x 1 S-Video Switch with Audio and Serial Control

Standard Operating Procedure of nanoir2-s

The DataView PowerPad III Control Panel

USER S GUIDE DSR-1 DE-ESSER. Plug-in for Mackie Digital Mixers

S M A R T U LT R A S O U N D

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

Software vs Hardware Machine Control: Cost and Performance Compared

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

Label Applicator HERMA 400

The Kaffeine Handbook. Jürgen Kofler Christophe Thommeret Mauro Carvalho Chehab

Electrocardiograph ECG-2550

Real-Time Spectrogram (RTS tm )

PulseCounter Neutron & Gamma Spectrometry Software Manual

A COMPUTERIZED SYSTEM FOR THE ADVANCED INSPECTION OF REACTOR VESSEL STUDS AND NUTS BY COMBINED MULTI-FREQUENCY EDDY CURRENT AND ULTRASONIC TECHNIQUE

Module 8 VIDEO CODING STANDARDS. Version 2 ECE IIT, Kharagpur

EAN-Performance and Latency

ksa ScanningPyro ksa ScanningPyro Full Carrier Temperature Maps at the Click of a Button!

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide

Reconstruction of Ca 2+ dynamics from low frame rate Ca 2+ imaging data CS229 final project. Submitted by: Limor Bursztyn

Operation Manual for. SCU1 Signal Conditioning Unit

Getting Started with the LabVIEW Sound and Vibration Toolkit

Release Notes for LAS AF version 1.8.0

4/14/2009. The Big Picture of Quality. MRI Quality Assurance and ACR MRI Accreditation Program. Basic Elements for Image Quality.

SignalTap Plus System Analyzer

RATE CARD & MEDIA KIT 2013

PS User Guide Series Seismic-Data Display

qeeg-pro Manual André W. Keizer, PhD v1.5 Februari 2018 Version 1.5 Copyright 2018 qeeg-pro BV, All rights reserved

GS Bloch Equations Simulator 1. GS Introduction to Medical Physics IV Exercise 1: Discrete Subjects

SC26 Magnetic Field Cancelling System

Appendix B DVB-T function operating manual

ESI VLS-2000 Video Line Scaler

RECOMMENDATION ITU-R BT

ТМ-04 Multichannel long range UHF alarm transmitter Operating manual. Sectron Ltd.

Lesson 14 BIOFEEDBACK Relaxation and Arousal

HBI Database. Version 2 (User Manual)

It will cause malfunction if the monitor is operating with unspecified power supply

New GRABLINK Frame Grabbers

Transcription:

WU-Minn HCP MEG Initial Data Release: Reference Manual Appendix I HCP MEG Session Protocol Details 4 March 2014 MEG1 Reference Manual Appendix I WU-Minn Consortium of the NIH Human Connectome Project Page 1

Table of Contents HCP MEG Scan Protocol Details... 3 Mailing List... 7 MEG1 Reference Manual Appendix I WU-Minn Consortium of the NIH Human Connectome Project Page 2

HCP MEG Scan Protocol Details HCP MEG data acquisition is performed on a whole head MAGNES 3600 (4D Neuroimaging, San Diego, CA) system housed in a magnetically shielded room, located at the Saint Louis University (SLU) medical campus. This document details the scan protocol and scanner parameters used for all HCP subjects selected for MEG scanning. See HCP MEG Initial Release Appendix II for Standard Operating Procedures used by HCP research staff to ensure consistent data acquisition between subjects. When planning MEG experiments on your local system, we caution that performance may vary from system to system, even within a single scanner platform. For best performance, you may need to adjust your protocols. Several key choices were made regarding the HCP MEG recordings. Sampling rate was selected to be as high as possible (2034.51 Hz) while collecting all channels (248 magnetometer channels together with 23 reference channels). Bandwidth was set (at DC, 400Hz) to capture physiological signals, and optimize file sizes and the signal-to-noise ratio. All our experiments were recorded in continuous mode to allow the greatest user flexibility in determining epoch widths in analyses. Since the bit noise on our system was higher than our sensor noise, Delta encoding is used to increase the bitrate. The order of scans in the HCP MEG protocol is as follows for all subjects: Scan Description Duration (min) 1-Rnoise Empty Room scan establishes a baseline noise level 5:00 2-Pnoise Patient scan, multiple if degaussing of the head is necessary. 1:00 Participant Digitization ~ 20 3-Restin First resting state scan, eyes open, fixated. 6:00 4-Restin Second resting state scan, eyes open, fixated. 6:00 5-Restin Third resting state scan, eyes open, fixated. 6:00 Break for button box placement ~2 6-Wrkmem First half, Working Memory scan 10:00 7-Wrkmem Second half, Working Memory scan 10:00 Break for otic placements ~2 8-StoryM First Half, Language scan 7:00 9-StoryM Second Half, Language scan 7:00 Break for muscle sensor placement (EMG) ~10 10-Motort First Half, Motor scan 14:00 11-Motort Second Half, Motor scan 14:00 MEG1 Reference Manual Appendix I WU-Minn Consortium of the NIH Human Connectome Project Page 3

In a particular session, multiple PNoise scans may be performed if the first shows artifact, generally from missed metal on the head or body of the participant, or dental work with residual magnetic fields. We can degauss the participant, if necessary, and in such cases the PNoise will be repeated until a good artifact-free scan is reviewed. The final PNoise in a subfolder will represent the baseline noise-state of this participant for other scans in the session. Particular scans may have been rejected from the data release for quality reasons in acquisition or preprocessing. The exact duration of each scan in seconds is variable as the recording brackets the stimuluspresentation time with buffer at the start and end. The screenshots below show the HCP acquisition setup and parameters set for the MAGNES 3600 magnetometer for an exemplar MEG session. In the first shot, the general acquisition parameters are shown. Duration is set at 2000 seconds for most scans, and manually stopped after the E-Prime run is concluded, to ensure the data are not prematurely clipped. MEG1 Reference Manual Appendix I WU-Minn Consortium of the NIH Human Connectome Project Page 4

In the Scan Information screenshot, whole head and the miscellaneous setup parameters are shown for a resting state scan. In all acquisitions 287 channels are acquired, always with a Gain of x1. In the Data File Information screenshot, Channel reference information is given for the first few channels. A complete listing of this info is contained in the headers, which are accessible by reading the data into MATLAB. Because we record continuous data, epoch information will reflect the whole scan as a single epoch. Points (times) sample period = epoch duration. MEG1 Reference Manual Appendix I WU-Minn Consortium of the NIH Human Connectome Project Page 5

MEG1 Reference Manual Appendix I WU-Minn Consortium of the NIH Human Connectome Project Page 6

Mailing List Individuals with further protocol-related questions are encouraged to use the HCP Data Users mailing list (hcp-users@humanconnectome.org) by signing up at http://www.humanconnectome.org/contact/ or by checking the appropriate box when registering to download HCP data. We also encourage individuals to share their protocols of what they find works best (and what does not) via this forum! MEG1 Reference Manual Appendix I WU-Minn Consortium of the NIH Human Connectome Project Page 7