RMA 3000 Remote Meter Assemblies Specifications

Similar documents
Model JDF Field Indicator

Rosemount 1151 Smart Pressure Transmitter

General Specifications

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Level Measurement Continuous level measurement - Capacitance transmitters

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Level Measurement Point level measurement - RF Capacitance switches

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

EXLUX ECOLUX C-LUX 6480 Series

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

General Specifications

Explosion Proof Audible Signal db(a) Series YA60

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Pressure transmitter For applications in hazardous areas Model IS-3

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Pendant Light Fitting IEC Series 6470/2

Inductive sensor With analog output BI15-M30-LI-EXI

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Level Measurement Point level measurement RF Capacitance switches

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

MODEL HS35 DRAWWORKS OPTICAL ENCODER

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

Process transmitter RMA422

Viper Ex the hazard free way to precise weighing results. Ex ia. The intrinsically safe compact scales combine leadingedge

PMG. Vibration Energy Harvesters

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TECHNICAL DATA. Type. TMC2X Design Specification. Category B ATEX Certificate. Code of Protection. IECEx SIR X Code of Protection

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Level Measurement Continuous level measurement Radar transmitters

PROPORTIONAL VALVES Sentronic plus

EXLUX ECOLUX 6480 Series

Horn loudspeaker, Ex proof, short/long flare

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Process Transmitter RMA 422

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

MAGNETOSTRICTIVE LEVEL TRANSMITTER

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

DMP 331i / DMP 333i LMP 331 i

Pendant Light Fittings Series 6050

Inductive sensor NI3-EG08K-Y1-H1341

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Modular Lube Lubrication Systems System Controls

TYPE APPROVAL CERTIFICATE

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

TFRN Industrial RTD temperature sensor. CombiTemp TM

XML LED X M L L E D. Explosionproof Linear LED Lighting

PRE Series 16 Amp Plugs and Sockets Increased Safety

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

Capacitance Level Measurement Electronic insert FEC 12

Flow Measurement SITRANS F M

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/224 Siemens FI Overview.

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

Explosion Proof Audible Signal db(a) Series YA60

Level Measurement Continuous level measurement Radar transmitters

TFR5 Room or outdoor temperature sensor. CombiTemp TM

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DPR100 C/D Pen and Multichannel Recorder: Digital Display

7 Lighting Technology

MAXX BOX. MX102/202 Series. MAXX Box

Inductive sensor BI1.5-EG08K-Y1

Veilux User Manual SVEX-Q18 Intelligence Camera Set

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

Flow Measurement SITRANS F M

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Champ-Pak Wall Pack Luminares

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Datasheet EC-750 Ex DOME Camera

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

RMA42. Technical Information

Pen and Multichannel Recorder: Digital Display

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.

I Ex-protected connectors exlink I

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

SQM40/41 Actuators for air and gas dampers

Installation instructions Ex frames

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Flow Switch. Flow Switch

2291 Guided Wave Radar Level Transmitter

PYROTENAX TERMINATION KITS COMMERCIAL WIRING. For Pyrotenax copper sheathed mineral insulated (MI) wiring cable

Inductive sensor NI10-M18-Y1X-H1141

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View)

Transcription:

RMA 3000 Remote Meter Assemlies Specifications 34-ST-03-81, July 2017 Introduction Overview The Remote Meter Assemly RMA 3000 functions as an output and status indicator for a compatile Honeywell Smartline transmitter or as an output indicator for a non- Honeywell transmitter operating in a 4-20mA current loop. The RMA 3000 is a convenient method to mount the meter (display) separately from the transmitter, thus it consists of a meter mounted in an aluminum explosion-proof housing in several protective paint styles availale. Two meter types are availale for mounting in the RMA 3000 housing: the Analog Meter (RMA300-ME), and the Engineering Unit Display Meter (RMA300-EU) The Analog Meter ME is used with analog output transmitters to give % output using a needle-type meter movement. The Engineering Units Meter EU provides digital display of temperature, pressure, level, flow, or other measurements in engineering units. This meter provides a universal solution for 4-20mA measurement displays y converting any 4-20mA signal into an LCD digital display in the preferred engineering units. The EU Display Meter is availale for remote-mount field use or can e integrally mounted with the STT250 temperature transmitter models STT25M (4-20mA only output), STT25H or STT25S (HART protocol output versions).

Highlights of Meter Features Features and Functions RMA300 - ME Function - The ME is an analog device that functions as an output indicator for any transmitter that operates in the 4-20 ma current mode. Application - The ME can e used as a Remote Meter Assemly component with any one of the Smartline transmitters operating in the analog (4 to 20 ma) mode. Electrical Characteristics The ME is an electromechanical device of the D Arsonval type. That is, the current passing through a coil in the meter is used to deflect a needle to indicate the magnitude of the current, where a current of 4-20 ma represents 0% to 100%. RMA300 - EU The EU Display Meter is connected in series with the 4-20mA loop and is powered y the loop power. It operates y processing the 4-20mA signal via an analog-to-digital converter and scaling the digital measurement linearly into the desired operating range, which the user configures into the meter. The LCD display includes a selection of integral engineering units for temperature and pressure applications (for example - C, F, in H2O, psi, etc. and a K multiplier that can e included when larger ranges require it). The EU Display Meter also includes a ar-graph display of measured signal as a percentage of the 16mA signal span. This enales confirmation from some distance away that the measurement loop is operating satisfactorily or that attention is required. The meter is configured y an integral selection switch, which enales setting the Low (4mA) and High (20mA) display range limits. HART is a trademark of the HART Communication Foundation.

RMA 3000 Remote Meter Assemlies 3 RMA300ME Specifications Operating Conditions Parameter Rated Extreme, Transportation and Storage Amient Temperature -40 to +176 ºF -40 to +80 ºC -58 to +194 ºF -50 to +90 ºC Relative Humidity 0 100% 0 100% Design Display Resolution ± 1% reading RMA300EU Specifications Operating Conditions Parameter Rated Extreme, Transportation and Storage Amient Temperature -40 to +185 ºF -40 to +85 ºC -58 to +194 ºF -50 to +90 ºC Relative Humidity 10 90%, non condensing 0 100% Design Digital Display Accuracy Digital Display Resolution Bargraph % Display Resolution Power Supply Volts drop across meter Connection Polarity Minimum Loop Current Availale Engineering Units Integral LCD indicator As stick on lael ± 0.5% of span Shown as: ± 0.05% for ± 199.9 reading range, 199.9 ± 0.5% for ± 1999 reading range, 1999 ± 5% for ± 19990 reading range 19990 ± 50% for ± 199900 reading range 199.9 K ± 500% for ± 1999000 reading range 1999 K ± 5000% for ± 19990000 reading range 19990 K ± 3% of reading on 17-segment scale 2.3 VDC with reverse polarity protection. Yellow = Positive (+ve); Blue = Negative (-ve) 3.6 ma ºF, ºC, %, in H2O, GPH, GPM, mmhg, PSI, PSIA Wide selection of printed units for temperature, pressure, and flow. All Displays Certification Conditions Installation Explosionproof/Flameproof 4ºF to +149ºF 20ºC to +65ºC 40ºF to +140ºF 40ºC to +60ºC Amient Limits Enclosure Specifications Material of Construction Numer of Conduit Openings Availale Adapters Paint Aluminum (SS availale) Two ½ NPT openings ½ NPT to M-20 316SS conduit adapter ½ NPT to ¾ NPT 316SS conduit adapter Beige or Red Epoxy

Approval and Certification Model Selection Guide, Tale III Approval Body None Factory Mutual CSA ATEX * None Approval Type Explosionproof, Dust Ignitionproof, Non-Incendive Enclosure: Type 4X Explosion Proof & Dust Ignition Proof Enclosure: Type 4X Flameproof Non Sparking Multiple Marking **, Flameproof and Non Sparking Location or Classification Class I, Div. 1, Groups A, B, C, D; Class II, III, Div. 1, Groups E, F,G; Class I, Div. 2, Groups A, B, C, D (DM, ME & SM, T4 at 40ºC) Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G; (ME T4 at 40ºC) Class I, Div. 1, Groups B, C, D; Class II, III, Div. 1, Groups E, F, G (ME T4 at 93ºC; EU, T4 at 60ºC) Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G; (ME T4 at 93ºC; EU, T4 at 60ºC) LCIE 02ATEX 6178X II 1 GD (Tale II= TG or TB); II 2 GD (Tale II= XC or XR); Ex ia IIC T5 (Ta= -40 to 60 C) Ex td A21 IP6X T95 C (at Ta = 85 C) or LCIE 02ATEX6177X II 2 GD Ex d IIC T6(Ta= -40 o C to 65 o C) or T5 (Ta= -40 o C to 85 o C) Ex td A21 IP6X T95 C (at Ta = 85 C) or HON 02.202 II 3 GD Ex na IIC T6 (Ta= -40 o C to 65 o C) or T5 (Ta= -40 o C to 85 o C) Ex td A22 IP6X T95 C (at Ta = 85 C) or LCIE 02ATEX 6178X II 1 GD (Tale II= TG or TB); II 2 GD (Tale II= XC or XR); Ex ia IIC T5 (Ta= -40 to 60 C) Ex td A21 IP6X T95 C (at Ta = 85 C) or LCIE 02ATEX6177X II 2 GD Ex d IIC T6(Ta= -40 o C to 65 o C) or T5 (Ta= -40 o C to 85 o C) Ex td A21 IP6X T95 C (at Ta = 85 C) or HON 02.202 II 3 GD Ex na IIC T6, -40 Ta 65 C Ex td A22 IP6X T95 C (at Ta = 85 C) or IECEx SAEx And Flameproof And Flameproof * See ATEX Installation requirements in the Operator manual Ex ia IIC T4 (Ta = -40 C to +85 C), T5 (Ta = -20 C to +60 C) Ex d IIC T6 (Ta = -20 C to +65 C), T5 (Ta = -40 C to +85 C) Ex ia IIC T4 (Ta = -40 C to +85 C), T5 (Ta = -20 C to +60 C) Ex d IIC T6 (Ta = -20 C to +65 C), T5 (Ta = -40 C to +85 C)

RMA 3000 Remote Meter Assemlies 5 Model Selection Guides are suject to change and are inserted into the specifications as guidance only. Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are pulished at: https://www.honeywellprocess.com/en-us/pages/default.aspx Model Selection Guide RMA 3000 Remote Meter Assemlies Model Selection Guide 34-ST-16-46 Issue 37 Instructions Select the desired key numer. The arrow to the right marks the selection availale. Make one selection from Tale I. Select Tale II options as desired. Key Numer I II (Optional) III RMA300 - -, - KEY NUMBER Description Selection Availaility Remote Meter RMA300 TABLE I - METER TYPE EU Meter Analog Meter EU ME EU ME TABLE II - OPTIONS No Selection Meter Housing Options Stainless Steel Customer wired-on Tag (4 lines, 28 characters per line, customer supplied information) Stainless Steel Customer wired-on Tag (lank) Mounting Bracket - Caron Steel Mounting Bracket - SS 1/2" NPT to M20 316 SS Conduit Adapter (BASEEFA EEx d IIC) 1/2" NPT to 3/4" NPT 316 SS Conduit Adapter Wiring Entry Plugs TB MB SB A1 A2 No Conduit Entry plugs supplied For conduit plugs,adapters and cale glands see the "Supplemenatal Accessories and Kits" section elow this tale XC XR SP 00 g h Beige Epoxy Painted Housing Red Epoxy Painted Housing End Cap Live Circuit Warning Lael in Spanish a End Cap Live Circuit Warning Lael in Portuguese PG a End Cap Live Circuit Warning Lael in Italian TL a End Cap Live Circuit Warning Lael in German GE a Warranty Options and Certificates User's Manual Paper Copy Certificate of Conformance (F2474) Additional Warranty - 1 Year Additional Warranty - 2 Years Additional Warranty - 3 Years Additional Warranty - 4 Years TG UM F3 W1 W2 W3 W4

Model Selection Guide Supplemental Accessories and Kits Conduit Plugs and Adapters may e ordered separately (M eter Assemlies come with plastic dust plugs as standard) Certified conduit plugs for CSA, ATEX and IECEx 1/2 NPT Certified Socket Plug 1/2 NPT Certified Socket Plug Certified adapters for CSA, ATEX and IECEx 1/2 NPT (male) to 3/4 NPT (female) 1/2 NPT (male) to M20 (female) Certified cale glands for UL and cul 1/2 NPT Description Material of Construction Part Numer ** Consult Honeyw ell Order Entry System for current parts pricing Zinc-plated Caron Steel 50021832-501 316 SS 50021832-502 316 SS 50000682-501 316 SS 51202409-501 Brass Nickel plated 50023212-501 TABLE III - APPROVALS RMA300 Availaility Approval Body None Factory Mutual CSA ATEX* None Approval Type Location or Classification Selection Explosionproof, Dust Ignitionproof, Non-Incendive Enclosure Rating Explosion Proof & Dust Ignition Proof Enclosure Rating Zone 0/1 / Zone 20/21 Flameproof Zone 1 / Zone 21 Class I, Div. 1, Groups A, B, C, D; Class II, III, Div. 1, Groups E, F, G;T4 at 40ºC Class I, Div. 2, Groups A, B, C, D Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G; T4 at 40ºC Type 4X Class I, Div. 1, Groups B, C, D; Class II, III, Div. 1, Groups E, F, G (ME, T4 at 93ºC; EU, T4 at 60ºC) Class I, II, III, Div. 1, Groups A,B,C,D,E,F,G; (ME, T4 at 93ºC; EU, T4 at 60ºC) Type 4X II 1 GD (Tale II = TG or TB); II 2 GD (Tale II = XC or XR) Ex ia IIC T5 (Ta = 20 C to +60 C), Ex td A21 IP6X T95 C (at Ta = 85 C) or II 2 GD Ex d IIC T5 (Ta = 40 C to +85 C) T6 (Ta = 40 C to +65 C) Ex td A21 IP6X T95 C (at Ta = 85 C) or Enclosure IP66/67 9X 1C 2J 3U 33 Non-Sparking Zone 2 / Zone 22 II 3 GD Ex na, IIC T5 (Ta = 40 C to +85 C) T6 (Ta = 20 C to +65 C) 3Y Ex td A22 IP6X T95 C (at Ta = 85 C) or (continued on next page)

RMA 3000 Remote Meter Assemlies 7 Model Selection Guide II 1 GD (Tale II TG or TB) ATEX* Multiple Marking ** Int. Safe, Zone 0/1, or Flameproof, Zone 1, or II 2 GD (Tale II= XC or XR) Ex ia IIC T5 (Ta= -40 to 60 C) II 2 GD Ex d IIC T6 (Ta= -40 o C to 65 o C) or T5 (Ta = 40 C to +85 C) Ex td A21 IP6X T95 C (at Ta = 85 C) or II 3 GD Ex na IIC T6 (Ta = 20 C to +65 C)or T5 (Honeywell) T5 (Ta = 40 C to +85 C) Ex td A22 IP6X T95 C (at Ta = 85 C) or 3C Non-Sparking Zone 2 Enclosure IP66/67 IECEx Flameproof, Zone 1 Intrinsically safe, Zone 0/1 Ex d IIC T6 (Ta = -20 C to +65 C), T5 (Ta = 40 C to +85 C) Enclosure IP66/67 Ex ia IIC T4 (Ta = -40 C to +85 C), T5 (Ta = 20 C to +60 C) CA SAEx Flameproof, Zone 1 Intrinsically safe, Zone 0/1 Ex d IIC T6 (Ta = -20 C to +65 C), T5 (Ta = 40 C to +85 C) Enclosure IP66/67 Ex ia IIC T4 (Ta = -40 C to +85 C), T5 (Ta = 20 C to +60 C) * See ATEX installation requirements in the Operator's Manual ZA **The user must determine the type of protection required for installation of the equipment. The user shall then check the ox [ ] adjacent to the type of protection used on the equipment certification nameplate. Once a type of protection has een checked on the nameplate, susequently the equipment shall not e reinstalled using any of the other certification types. RESTRICTIONS Restriction Letter Availale Only With Not Availale With Tale Selection Tale Selection a III 3U,33,3Y,3C Select only one option from this group g III 3U, 33, 3Y, 3C, CA, ZA h III 1C, 2J Notes: See 13:ST-OE-9 for OMS Order Entry Information including TC, manuals, certificates, draw ings and SPINS. See 13:ST-27 for Pulished Specials w ith pricing. Ordering Example: RMA300-EU-MB,TG-2J

Sales and Service For application assistance, current specifications, ordering, pricing, and name of the nearest Authorized Distriutor, contact one of the offices elow. ASIA PACIFIC Honeywell Process Solutions, Phone: + 800 12026455 or +44 (0) 1202645583 (TAC) hfs-tacsupport@honeywell.com Australia Honeywell Limited Phone: +(61) 7-3846 1255 FAX: +(61) 7-3840 6481 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-04-70 China PRC - Shanghai Honeywell China Inc. Phone: (86-21) 5257-4568 Fax: (86-21) 6237-2826 Singapore Honeywell Pte Ltd. Phone: +(65) 6580 3278 Fax: +(65) 6445-3033 South Korea Honeywell Korea Co Ltd Phone: +(822) 799 6114 Fax: +(822) 792 9015 EMEA Honeywell Process Solutions, Phone: + 800 12026455 or +44 (0) 1202645583 Email: (Sales) FP-Sales-Apps@Honeywell.com or (TAC) hfs-tac-support@honeywell.com AMERICAS Honeywell Process Solutions, Phone: (TAC) (800) 423-9883 or (215) 641-3610 (Sales) 1-800-343-0228 Email: (Sales) FP-Sales-Apps@Honeywell.com or (TAC) hfs-tac-support@honeywell.com The information and specifications in this document are suject to change without notice For more information To learn more aout RMA300, visit www.honeywellprocess.com Or contact your Honeywell Account Manager Process Solutions Honeywell 1250 W Sam Houston Pkwy S Houston, USA, TX 77042 Honeywell Control Systems Ltd Honeywell House, Skimped Hill Lane Bracknell, England, RG12 1EB Shanghai City Centre, 100 Jungi Road Shanghai, China 20061 www.honeywellprocess.com 34-ST-03-81 July 2017 2017 Honeywell International Inc.