BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

Similar documents
2017 TECHNICAL SPECIFICATIONS

Matt Dann Cultural Centre

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Specification

Technical Pack. Attenborough Arts Centre

THE STREET THEATRE. Technical Specifications

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Phoenix Theatre Elwood

New Theatre Royal Lincoln Technical Information

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Technical specifications Main theatre. Sound

DEREHAM MEMORIAL HALL

HIRE AND TECHNICAL INFORMATION

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Where performance matters

332 fixed seats (max capacity) with reserved space for disable access

CENTRE FOR PERFORMING ARTS

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Lighthouse Theatre Technical Specification

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

RPAC REDLANDS PERFORMING ARTS CENTRE

Technical Specification Pavilion Dance

Main Stage Technical Specs - Hall #2

Latrobe Performing Arts Centre

A red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience.

Technical Information

Arcadia Performing Arts Center Technical Specifications and Information

INFORMATION PACK & SCHEDULE OF RATES 2015

JERWOOD VANBRUGH THEATRE

Technical Pack. Embrace Arts at the RA Centre

Technical Information

Technical Specifications

Dr JOHN GALLAGHER CONCERT CHAMBER

Access to back stage is off Fletcher St on the eastern side of the building

John Leslie Theatre. Technical Specifications. Updated July 2018

Technical Specification for the Alley Theatre, Strabane

TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem,

Theatre Technical Specifications

Technical Data Sheet

Shouson Theatre Venue Specifications (updated Jan 2017)

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

SUSAN AGLUKARK. Keynote Speaker/ Solo Presentation TECHNICAL RIDER HOSPITALITY RIDER 2018 Revision 1/15/18 KEY CONTACT:

Technical Specification

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Technical Specifications

Technical Specification

350 fixed seats with the capabilities of an additional 50 removable seats.

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Technical Specifications

ISLAND HALL TECHNICAL INFORMATION

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Technical Specifications. Taylor Little Theater

Visy Theatre technical information and general specifications 2019

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Technical requirements & conditions for hirers

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Facility Information

Barney Simon Theatre Technical Specifications

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Hopgood Theatre NOARLUNGA CENTRE

Monash University Academy of Performing Arts

BRAMALL INTRODUCING THE. Venue hire for classical & pop music, spoken word & comedy

DOMINO THEATRE INC. THEATRE TECHNICAL SPECIFICATIONS AND INFORMATION

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Specifications Updated 01/10/2017. Stage

Marjorie S. Deane Little Theater

The Mannie Manim Technical Specifications

Technical Specifications and Inventory Spring 2018

Tucker Theatre Policies and Procedures MTSU Department of Theatre 205 Boutwell Dramatic Arts Murfreesboro, TN 37132

Main House Technical Specification

Monash Academy of Performing Arts

ROSE THEATRE BASEMENT

Cornerstone Technical Specifications 2018 / V1

Technical Specifications

ROSE THEATRE MAIN THEATRE

Sandusky State Theatre Technical Specifications

Theatre Technical Specification

Matthew Flinders Theatre

Downtown Arts Center Tech Packet. General Information

COURTYARD!!!!! THEATRE

Melrose Veteran s Memorial Middle School Auditorium 250 Lynn Fells Parkway, Melrose, MA, 02176

Patriots Theater at the War Memorial Technical Data

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

Technical Specification Ardhowen Theatre

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

INFORMATION FOR VISITING COMPANIES

Please carefully read this entire form before completing any information.

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Transcription:

BANYULE THEATRE TECHNICAL INFORMATION 10 Buckingham Drive Heidelberg VIC 3084 Page 0 of 10

Contents 2. Brief Description 3. Features 5. Stage Measurements 6. Audio 7. Lighting 8. Standard Lighting Rig 9. Theatre Layout Plan 10. Contact Information Page 1 of 10

Brief Description The Banyule Theatre consists on ten rows of tiered seating, providing for a total audience of 265. All seats have padded upholstery and floors are carpeted in keeping with the complex colour scheme of maroon and blue. The entrance and foyer area is attractively designed with timber and brick, and features a casual seating area to seat approximately 10 people. The foyer features a large pin board that may be used by the hirer. The stage is polished floorboards, featuring black legs and borders and a red velvet electrically controlled house curtain. Two internal change rooms are located to the rear of the stage, as well as a studio area approximately the same size as the stage, minus the apron. Change rooms include, large mirrors, clothes rails, sinks and taps, and a video and audio feed of the stage. Toilets are located in the area between the change rooms and the studio area. Change rooms are also accessible from the rear of the building. Two additional external 3m x 6m Change rooms are located at the rear of the building. Both contain a video and audio feed of the stage. (Available at an additional cost) The stage features large wings suitable for storing large set pieces including flats, a video feed is supplied to both Prompt and Off-Prompt wings. The stage managers desk is located in the prompt wing and includes controls for the house curtain, house lights, stage work lights as well as blue work lights in the wings. A Bio Box is located at the rear of the auditorium and includes audio console, CD Player and facilities to play audio from a computer/mp3 player. There is also a programmable lighting console and talkback communications with both prompt and off-prompt wings. The Banyule Theatre has excellent car parking facilities that are partially shared with the neighbouring football club. Also within the Theatre Complex is a mid-sized multi-purpose room known as the Milpara Room. This room is large enough to accommodate approximately 80 people and has a serving window from the Kitchen/Kiosk. This room is available for an additional fee. The Kitchen/Kiosk is available upon request and includes ample bench space, fridge/freezer, microwave, urn, pie warmer and washing up facilities. Access for the kitchen is available from both the interior and exterior of the building and has 2 serving windows, one to the Milpara Room and one to the foyer area. A knowledgeable Theatre Technician will be in attendance at all times while the theatre is in use, and will be responsible for operating all audio and lighting requirements etc. An extra technician may be available upon special request to the theatre manager. Page 2 of 10

Features Stage The Banyule theatre features a thrust stage finished in polished floorboards, alternatively the stage floor can be covered by a layer of chip board that may then be painted. (This is to be done by the theatre technicians and will incur an additional cost, charged at the time that it takes to be completed.) A large projection screen is suspended above the stage, approximately 1m behind the proscenium arch. A data projector is available upon request. Can be operated from the bio box or prompt side of stage Wings Banyule Theatre contains ample wing space (approximately equal to the stage space); each wing is concealed by 3 x black woollen legs. Both wings contain a TV monitor featuring a video loop of the front of stage. Both wings also contain a talkback loop There is a stage door on the far side of both wings, and the prompt side also acts as a loading bay, complete with roller door Loading bay roller door dimensions: 2700mm x 2900mm Located on the Western side of the complex, at street level Studio Located behind the stage is a large studio area, suitable for housing an orchestra of up to 20-30 members. The size of the studio area is similar to that of the stage and features 3 overhead lighting bars complete with patch points (no fixtures are located on these bars when in standard rig) During shows the studio area is dimly lit in blue light Bio Box/Projection Room The bio box can comfortably house 2 to 3 people during shows; a venue technician must be present at all time while the bio box is occupied. Page 3 of 10

Ticket Office A small room located in the foyer is suitable for use as a ticket office, this room can seat 1 person, a power point is located in the room as well as a table and chair. Also features a 2-part door (Top half may move independent to the bottom). This room can be locked during shows to secure any money or documents kept inside. This room is available upon request from the venue technician. As this room is also used as storage, prior notice is requested for its use. Milpara Room Within the Theatre Complex is a mid-sized multi-purpose room known as the Milpara Room. This room is large enough to accommodate approximately 80 people and has a serving window from the Kitchen/Kiosk. This room is available for an additional fee. A projection screen is located within this room, and a data projector is available upon request, if it is not in use in the theatre Dimensions: 10780mm x 8411mm Milpara Room Page 4 of 10

2650mm Proscenium Arch 4400mm 11000mm 5500nm 5340mm 590mm 3500mm 8840mm 11000mm 5340mm Studio Area 11000m 6500mm 590mm 5340mm Banyule Theatre Stage Measurements 5500mm Drawing For Illustrative Purposes Only Page 5 of 10

Audio The Banyule Theatre features an audio system capable of fulfilling the needs of most functions, from Seminars and Lectures through to Amateur Theatre and School Productions. Additional audio equipment may be hired from external sources, but all equipment bought into the Banyule Theatre must have current electrical safety tags. Equipment is as follows: Audio Consoles Behringer X32 40-Input, 25-Bus Digital Mixing Console with 32 Programmable MIDAS Preamps, 25 Motorized Faders, Channel LCD's, 32-Channel Audio Interface and ipad/iphone Remote Control Compatible (Not Supplied) Yamaha MG2414FX 24 channels, 6 Auxiliary sends, 4 Groups, 2 Inbuilt Effects Channels Amplifier Crown CE-1000 Power Amplifier 275W @ 8-ohm stereo (per channel) Speakers FOH: Foldback: 2x Wharfedale EVP-15 NEO 15 Inch Passive 2-Way Loudspeaker 1 Inch Horn 8-Ohm Impedance Continuous: 300w Peak: 1200w 2x Quest QSA200i 8 Inch Powered 2-Way Loudspeaker ¾ Inch Horn Continuous: 100w Microphones 4x Shure SM58 Dynamic Vocal Microphone 1x Australian Monitor Paging Microphone 2x Shure PGXD Wireless Handheld Microphone, Beta 58 Capsule Playback Equipment 1x Sony CDP-XE300 CD player Miscellaneous 16 Channel, 4 Return Multi-Core Various straight and boom style microphone stands Various XLR Cables Various cable adapters Please Note: The Banyule Theatre stocks cables sufficient to run venue equipment, leads required to run externally sourced equipment must be supplied by the hirer. Page 6 of 10

Lighting The Banyule Theatre features a lighting system capable of fulfilling the needs of most functions, from Dance Concerts through to Amateur Theatre and School Productions. Additional lighting equipment may be hired from external sources, but all equipment brought into the Banyule Theatre must have current electrical safety tags. Equipment Is As Follows: Lighting Console LSC Maxim M 48 channel, 24 Preset Programmable Lighting Console Adjustable Fade In/Out times Floppy Disk Drive (To Save Shows) Video Output Dimmers 2x LSC Series A 12 x 2.4kVA Analogue Dimmer 1x Rank Strand JTM Dimmer Rack 20 x 2.4 kva (PLEASE NOTE: Some dimmer channels are not operational and are unable to be repaired, please contact Venue Technician on 0400 837 325 for more information) Patching Rank Strand JTM 110 Patch Point Patch Bay 82 Patch Points in Stage Area 28 Patch Points in Studio Area Miscellaneous 2x Startec Demultiplex Unit (Digital To Analogue Converter) Data Projector A 2600 Lumen Data Projector is available on request, it is suitable for projecting onto the Projector screen, located approx. 1m behind the house curtain. The projector is NOT suitable for projecting backdrops onto the cyc. Lighting Fixture Library Quantity Manufacturer Model Type Wattage 16 Strand Pattern 803 Fresnel 650 6 Strand Pattern 223 Fresnel 1000 5 Strand Pattern 23 Mk II Profile 500 2 Strand T-64 Profile 1000 2 Strand Pattern 23 Mk II N Zoom Profile 500 2 Strand T-84 Zoom Profile 1000 4 Nova LED Tri-Par Mk II LED Par Can 120 12 Generic Par 64 Par Can 1000 x2 2 - - Flood 1000 Page 7 of 10

Lighting Notes No barn doors available An additional 32a 3-Phase outlet is available in the bio box, Additional dimmer or Power Distribution Unit is to be supplied by the hirer if necessary Limited gel stock available, specific and or large quantities of gel are to be supplied by the hirer A 3 and 5 pin data splitter is located in the OP Wing, 3pin Data is run to the OP side of each lighting bar. 4 spare 5pin DMX outputs are located at the splitter. LED Par Cans run on 6 DMX channels (intensity, red, green, blue, strobe speed and preset mode). Output is similar to that of a 1000w conventional fixture. Beam angle is fixed at 35 degrees. House(audience) lighting is controlled from the Bio Box Only Any lights hired or supplied by the hirer must have current electrical safety tags. Please Note: The Banyule Theatre stocks cables sufficient to run venue equipment, leads required to run externally sourced equipment must be supplied by the hirer. STANDARD LIGHTING RIG Page 8 of 10

Page 9 of 10

Contact Booking Information Theatre Manager: Lisa Provis 8458 2843 lprovis@viewbank.vic.edu.au Available School Hours: Monday, Wednesday & Friday Technical Information Theatre Technicians: Ben Mogford & Jessica Brown 0400 837 325 banyuletheatre@hotmail.com Available All Times If no answer please leave a message Page 10 of 10