ACCURATE FAT AND MOISTURE ANALYSIS HAS NEVER BEEN EASIER!

Similar documents
ACCURATE FAT AND MOISTURE ANALYSIS HAS NEVER BEEN EASIER!

vacuum analysis surface science plasma diagnostics gas analysis

Advanced Test Equipment Rentals ATEC (2832)

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

Operation Manual. Corporation

SC24 Magnetic Field Cancelling System

DVG MPEG-2 Measurement Generator

Advanced Test Equipment Rentals ATEC (2832)

SC24 Magnetic Field Cancelling System

SPECIFICATION NO Model 207 Automatic GTAW Welding System

M4000 Diagnostic Test System For Power Apparatus Condition Assessment

SAL Series Wireless Clock (V1)

Eddy Current Technology. eddyliner. digital

CTC Series. Compact Temperature Calibrator

Noise Detector ND-1 Operating Manual

PHOENIX Finds every leak. Now with an even fi ner nose.

Magnetic Stirrers Magnetic Stirr

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

EDDYCHEK 5. Innovative eddy current testing for quality and process control. Touchscreen. Networking. All major applications.

Modular Expansion Cards

ABB MEASUREMENT & ANALYTICS. MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC

X-Band Redundant LNB Systems

SY-401V PC/HD to Video Scan Converter OPERATION MANUAL

ABB MEASUREMENT & ANALYTICS. MB3000 The most reliable FT-IR laboratory analyzer

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

Portable Performance for Debug and Validation

Model ED 400 Drying and heating chambers Classic.Line with natural convection

1/3 RACK-MOUNTED BLOCK CONVERTERS

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Ku-Band Redundant LNB Systems

Oscilloscopes for field applications

DISTRIBUTION AMPLIFIER

C-Band Redundant LNB Systems

PROCESS HEAT. From LE to LHS: How to benefit from Leister s new generation of air heaters. We know how.

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

SY-MS121 SY-MS121-AP

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

Hitachi Kokusai Electric Comark LLC

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

515 PIPEMASTER. Features. Options PROGRAMMABLE POWER SOURCE FOR ORBITAL WELD HEADS

HTE Owner s Manual. HDMI, RS-232, IR & Ethernet Extender over HDBaseT with 3D, 4K, POE Support

SC26 Magnetic Field Cancelling System

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

InSight Pro. Valuable real-time process insight

LCD Display Wall Narrow Bezel Series

Thermo Scientific Polar Series Cooling/Heating Recirculating Chillers

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

R-1580A Microwave Downconverter. Product Brochure

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Agilent 87075C Multiport Test Set Product Overview

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

Power supply for MPPC

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

CPLUS-V4T 4K UHD HDMI Splitter

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

Lite USER GUIDE. 3 Lite. For more information visit

1215L 12 LCD Desktop Touchmonitor

Engineered to meet your needs T he oldest name in stud welding,

Selection Table. Ordering Information

Product Guide. WaveAnalyzer High-Resolution Optical Spectral Analysis

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Programat P310. Economical firing performance. Top-quality results. The user-friendly furnace. Now with new OSD display

R-1550A Tempest Wide Range Receiver

SCALE & WEIGHT DISPLAYS

Calibrating attenuators using the 9640A RF Reference

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Generator protection relay

Satellite Up- and Downconverter Indoor / Outdoor

Model KBF 115 Constant climate chambers with large temperature / humidity range

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

CONSUMER UPS SINGLE PHASE UPS UP TO 3000 VA THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

CH-2538TXWPKD 4K UHD HDMI/VGA over HDBaseT Wallplate Transmitter. CH-2527RX 4K UHD HDMI over HDBaseT Receiver. Operation Manual

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

USER GUIDE 3. For more information visit

Model KT 170 Cooling incubators with thermoelectric cooling

Model ED 23 Drying and heating chambers Classic.Line with natural convection

UFX-EbNo Series Precision Generators

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Thermo Scientific NESLAB ThermoFlex Recirculating Chillers

R&S RT-Zxx High-Voltage and Current Probes Specifications

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

Intelligent Security and Fire Ltd

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Sigma 4-16S Sigma 4-16KS Sigma 4-16KHS

HOME THEATER. HDMI Selector Switches. Vanco Part Numbers (5x1) (3x1) Technical Support

PINMRF. Checkout Quiz - Varian Inova-300 Version

The extremely compact laser head is approximately 480 mm long and can

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

IGNITION TRANSFORMER FOR BURNERS

1928L Multifunction 19-inch Desktop Touchmonitor

PU-515PL-KIT HDBaseT LITE Extender Kit with PoE & 2-way IR (up to 60m) OPERATION MANUAL

It will cause malfunction if the monitor is operating with unspecified power supply

Overview. Dimensions and weights 1. Specifications SMART Board 7086 interactive display Model SBID-7086

EX-IQ-Box Digital Signal Interface Module Specifications

Transcription:

ACCURATE FAT AND MOISTURE ANALYSIS HAS NEVER BEEN EASIER! Analyze for moisture/solids with SMART Turbo 1 Roll sample and place in Trac Tube 2 Insert into NMR chamber for analysis 3 Precise results in 8 seconds!

FAST, ACCURATE ANALYSIS for MOISTURE/SOLIDS, FATS and OILS A Winning Combination! RAPID ANALYSIS SYSTEM For Moisture/Solids, Fats and Oils The SMART Trac II partners advanced, high performance NMR technology with the fast, reliable drying capability of the SMART Turbo Microwave Moisture/Solids Analyzer to create a system which yields fast, accurate results without solvents or calibration. Results for the percentage of moisture, solids and fat are simple and easy. Analyze twice as many samples per day Green! No solvents, 95% less energy needed No costly calibration maintenance More accurate than FTIR and NIR AOAC Compliant (Method 2008.06) SMART Turbo Microwave Moisture/Solids Analyzer The SMART Turbo provides rapid, accurate moisture/ solids analysis for a broad range of products. The system s patented IntelliTemp TM temperature control ensures that all moisture is completely removed without overheating the sample for better precision. SMART Turbo accurately analyzes a wide variety of sample types including solids, powders, slurries and liquids (0.1-99.9% moisture). High Performance NMR Technology NMR directly measures fats and oils. Unlike indirect methods, which only measure the surface of a sample, NMR detects fats and oils throughout the sample, yielding an accurate analysis that is independent of sample uniformity and not affected by changes in color or texture. PARENT % Fat % Solids Heavy Cream 31.20 36.76 Milk 3.65 12.83 CHILD 1 CHILD 2 Easy Method Transfer SMART Trac II has standard methods that are included with the instrument. Simply select from a list of methods and start analyzing without additional calibration. Custom methods are also available. Contact our applications support group and we can e-mail them to you directly. Combine this with the incredible stability of the SMART Trac II and you have a remarkably easy-to-use instrument that you never have to re-calibrate. Once a method is developed on a PARENT; it can be copied to a CHILD and used immediately. You get the same results whether you are transferring methods across the lab or across the ocean. % Fat % Solids Heavy Cream 31.13 36.74 Milk 3.67 12.83 % Fat % Solids Heavy Cream 31.24 36.83 Milk 3.67 12.86

RAPID ANALYSIS SYSTEM For Moisture/Solids, Fats and Oils RAPID ANALYSIS Turbo Technology for the fastest moisture/solids analysis SYSTEM STATUS AT A GLANCE Ready Insert Sample Analyzing EXCELLENT PRECISION with proprietary Intelli-Temp TM temperature feedback system ON-BOARD PRINTER LIMS READY ethernet and serial ports TEST PRECISION TO 0.01% Results in % moisture, % solids & % fat Also calculates %protein STORES 100 METHODS & 300 TEST RESULTS SIMPLE USER INTERFACE RAPID ANALYSIS newly designed NMR analyzes fat in 8 seconds NEVER RECALIBRATE all operators and all shifts get the same results COMPACT NMR state of the art neodymium magnet PROGRAMMING IN 5 LANGUAGES (English, French, Spanish, Italian & German) EASY ACCESS to microwave chamber and balance pan Only CEM Has The Intellitemp TM Advantage SMALLER SIZE/LIGHTER WEIGHT fits easily in laboratory environments WEIGHT STORED AUTOMATICALLY by a built-in analytical balance that continuously weighs the sample during the drying process GREEN METHOD No solvents and SMART Trac II uses 95% less energy than conventional methods IntelliTemp continuously monitors the sample during the drying process and adjusts the microwave power, providing reproducible testing conditions by consistently maintaining the user-de ned temperature setpoint. Results are always precise and reproducible, even between laboratories!

WHAT IS NMR & HOW DOES IT WORK? A BETTER SOLUTION NMR quanti es fats and oils in samples and eliminates the need for time consuming extractions and solvents. Nuclear Magnetic Resonance (NMR) is the same technique as Magnetic Resonance Imaging (MRI), which has been widely used in the medical profession for years to image the human body. CEM combines microwave drying with NMR to accurately measure fats and oils. The SMART Turbo removes all of the water molecules from the sample, eliminating signal interference and allowing the NMR to accurately measure the amount of fat content in a wide variety of food products. NEW SMALLER SIZE In most laboratories, benchtop space is at a premium, so we designed the SMART Trac II with a new, compact magnet that is smaller than any comparable instrument. The system requires no external computer and the at panel LCD display can be used freestanding or mounted on the back of the magnet. The magnet and electronics are housed in separate units so that the electronics unit can be placed on the oor, under the bench, or even on a shelf to save bench space. The word nuclear in the name of the technique refers to the instrument s ability to analyze the nuclei of the sample s atoms. NMR technology does not generate or use ionizing radiation. Rapid Moisture/Solids Fat Analysis ANALYZE TWICE AS MANY SAMPLES EVERY DAY (min:sec) SMART Trac I SMART Trac II Milk 4:45 2:51 Cream 3:36 2:24 Cheddar 3:59 2:03 Ketchup 3:52 2:23 Hot Dog 6:00 2:21 Beef 5:02 3:30 DELIVERS THE SAME QUALITY PERFORMANCE UP TO 10 FEET AWAY

MOISTURE/SOLIDS RANGE FAT RANGE BALANCE CAPACITY PROGRAM/DATA STORAGE STANDARD SOFTWARE DATA ENTRY SYSTEM SPECIFICATIONS 0.01% to 99.99% in liquids, solids and slurries. 0.01% resolution 0.01% to 99.99% in liquids, solids and slurries, 0.01% resolution 100 grams, 0.1 mg readability 100 methods and 300 results Software with proprietary Turbo Technology and IntelliTemp Temperature Controlled Drying. Keypad with menu-driven software DISPLAY Black and white VGA (320 x 240) Optional at panel LCD display ACCESSORY PORTS STANDARD PRINTER NETWORK INTERFACES INSTRUMENT DIMENSIONS: SMART Turbo SMART Trac II Magnet SMART Trac II Processor WEIGHT: SMART Turbo SMART Trac II Magnet SMART Trac II Processor AMBIENT AIR TEMPERATURE VOLTAGE POWER CURRENT SMART Turbo SMART Trac II Magnet & Processor Power Conditioner Requirements RF PULSE GENERATOR: MAGNET: SIGNAL DETECTION: 2 serial, RS 232, 9 pin ports for network connection, external balance, or bar code reader, Parallel Port for external printer, 4 USB ports, 1 Ethernet CAT 5 port Internal impact printer RS232, USB, Ethernet 22 in (w) x 23 in (d) x 15 in (h) 56 cm (w) x 59 cm (d) x 37 cm (h) 14 in (w) x 14 in (d) x 13 in (h) 36 cm (w) x 36 cm (d) x 33 cm (h) 12 in (w) x 13 in (d) x 16 in (h) 30 cm (w) x 33 cm (d) x 41 cm (h) May be located up to 9 8 (3m) away from the magnet. 55 lbs, 25 kg 110 lbs, 50 kg 37 lbs, 17 kg Temperature must be between 15 C and 30 C. For optimum stability and performance, the ambient temperature should not vary more than 5 C/day. 100-240 V (50-60 Hz) 800 VA maximum, UPS recommended if power is not reliable 10 amps (110-127 V, 60 Hz); 5 amps (220-240 V, 50/60 Hz 10 amps (100 V, 50/60 Hz); 5 amps (200-208 V, 50/60 Hz) 6.3 amps (100-240 V, 50/60 Hz) 2.1 kva 120 V, 60 Hz 1.8 kva 240 V, 50 Hz Pulse power 300 W nominal. Pulse times variable in 100 ns increments. Transmit and receive phases selectable 0, 90, 180 and 270. Nominal 90 pulse times 3 s (10 mm probe) and 4.5 s (18 mm probe) Permanent, thermally stabilized, 0.55 T (23.4 MHz proton), Homogeneity better than 10 ppm Dual channel (quadrature) detection with programmable low-pass ltering. Programmable data acquisition rate up to 10 MHz per pair of points. PATENTS 6,548,303 6,548,304 7,125,721 7,220,591 Winner of the R&D 100 and the NSPE New Product Awards ISO 9001:2000 certifies that the CEM quality management system meets internationally accepted standards. CEM Corporation P.O. Box 200 Matthews, NC 28106 United States Tel: (800) 726-3331 USA & Canada Tel: (704) 821-7015 Fax: (704) 821-7894 e-mail: info@cem.com http://www.cem.com CEM Microwave Technology Ltd. 2 Middle Slade Buckingham Industrial Park Buckingham MK18 1WA United Kingdom Tel: (44) 1280-822873 Fax: (44) 1280-822873 e-mail: info.uk@cem.com CEM GmbH Carl-Friedrich-Gauss -Str. 9 47475 Kamp-Lintfort Germany Tel: (49) 2842-9644-0 Fax: (49) 2842-9644-11 e-mail: info@cem.de www.cem.de CEM S.R.L. Via Dell Artigianato, 6/8 24055 Cologno al Serio (Bg) Italy Tel: (39) 35-896224 Fax: (39) 35-891661 e-mail: info.srl@cem.com CEM Wave S.A.S. Immeuble Ariane Domaine Technologique de Saclay 4, rue Rene Razel 91892 ORSAY Cedex France Tel: (33-1) 69 35 57 80 e-mail: info.fr@cem.com B033.2