FASO DANCE COMPANY KALAKUTA REPUBLIK

Similar documents
PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

Technical Rider. GöteborgsOperans Danskompani. Tour to xxx. Alaska. Table of Contents: 2. Stage. 3. Lighting. 4. Sound. 5. Medical. 6.

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Technical Rider "THEATRE" by SUPERAMAS

Technical Rider. GöteborgsOperans Danskompani. Spirit Tour to XX DATE to DATE. Table of Contents: 1. The Company

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

Technical Rider. GöteborgsOperans Danskompani. Untitled Black. Tour to.. Table of Contents: 2. Stage. 3. Lighting. 4. Sound. 5. Medical. 6.

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

TECHNICAL RIDER. If you have problems to fulfil some of our demands, please don t hesitate to contact us. We will find a solution!

TECHNICAL REQUIREMENTS

JAMIE ADKINS. Circus INgognitus. Technical Rider Version: January, 2014

TECHNICAL RIDER March 30th 2015

TECH SHEET AND INFORMATION (Updated )

[technical list] updated 27/09/2017. Groupe Emile Dubois My Ladies Rock Creation September Playing time : 1h15 without intermission

The set is very simple. It consists of one small box, a small stool, and a small ping- pong table.

The Bapo (horn) Show

The Willoughby Brothers

"The Road Is Just A Surface" by Anja Garbarek and Jo Strømgren Kompani Technical Requirements

Technical Rider Attached is a technical Rider covering schedule, technical and practical requirements, and contacts. Changes may occur.

Barney Simon Theatre Technical Specifications

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

SADNESS EXTENDED TECHNICAL RIDER

DEREHAM MEMORIAL HALL

Performance: Romanesco

Avant Garde Dance & The Place Fagin s Twist Tech Spec 2016

SUPERAMAS Technical Rider YOUDREAM

Everyness. Wang Ramirez Company TECHNICAL RIDER

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

TECHNICAL SHEET Show: Machine de Cirque

The Mannie Manim Technical Specifications

TECHNICAL REQUIREMENTS

Technical Specification Pavilion Dance

Matt Dann Cultural Centre

Enormous Room Technical Rider & General Lighting Plan

Tabarnak Technical Rider

Borderline. Company Wang Ramirez TECHNICAL RIDER

Dr JOHN GALLAGHER CONCERT CHAMBER

SOUND TECH RIDER FIDO

CENTRE FOR PERFORMING ARTS

Borderline. Company Wang Ramirez TECHNICAL RIDER

Technical Specification

RIDER 2018 version 1 English

HALFWAY TO DAWN TOUR

Technical Rider. STAGE 32 m wide x 13 m deep (from the prompt)

Technical Rider. Update: may 6th 2008

Timber! Technical Rider

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point)

THEATRE EQUIPMENT DECEMBER 2017

TECHNICAL SPECIFICATIONS

JANE RUTTER AUSTRALIA S FIRST LADY OF THE FLUTE

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Technical Pack. Attenborough Arts Centre

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Roberto SOLO Fonseca

Project manager (PM): Pamela Næss Mail: Phone:

Technical Production Rider degeneration For venues in mainland Europe

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

INFORMATION FOR VISITING COMPANIES

New Theatre Royal Lincoln Technical Information

Technical Specification

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Project manager (PM): Pamela Næss Mail: Phone:

Technical Specification

TECHNICAL RIDER FOR GROUND FREIGHT-TOURING

2017 TECHNICAL SPECIFICATIONS

Main House Technical Specifications

technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Technical specifications - Compagnie José Besprosvany Prométhée enchaîné

HIRE AND TECHNICAL INFORMATION

Theatre Technical Specifications

Pleasance London Main House Visiting Company Information Pack May 2017

Jane Mallet Theatre Technical Specifications

Live From Nashville TECHNICAL RIDER

Monty Kultuurfaktorij Technical Rider

CONTACTS Jani Lauzon Managing Artistic Director

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Technical Information

Technical Data Sheet

Technical Specifications Updated 01/10/2017. Stage

Technical Specification. Updated: April 2016

SHIVER. Technical rider update : 10th feb Premiere at Theater l Arsenic in Lausanne/Suisse the 4th of february 2014

THE STREET THEATRE. Technical Specifications

VENUE TECHNICAL REQUIREMENTS

Main House Technical Specification

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

Uprising & The Art of Not Looking Back

TECHNICAL RIDER KOMEDIE

Rider Part1: Technical Requirements, A Cappella Show

Technical Specification Ardhowen Theatre

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Technical specifications Main theatre. Sound

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

HUECO / Technical Rider

Where performance matters

Not Fade Away. The Ultimate Buddy Holly Experience. TECHNICAL RIDER Video Projection is Recommended

Transcription:

Technical Rider final version FASO DANCE COMPANY KALAKUTA REPUBLIK Serge Aimé Coulibaly Technical coordination: Sam Serruys - Tel: +32477362335 - sam.serruys@me.com Production and tour management: Laure Louvat - Tel: +33664216440 - laurelouvat@gmail.com

Timetable Arrival: 09:00 AM Setup Video and sound: 09:00-13:00 Setup light and focus: 09:00-13:00 Set up set: 09:00-13:00 Lunch: 13:00-13:30 Finalizing light + sound + video: 13:00-16:00 Arrival Dancers for warm-up and spacing: 16:00 19:00 Doors open: 15 minutes before start show Showtime Part 1: 40min Pauze: 15min Showtime Part 2: 30min Strike: 45 min Dinner: After performance including technicians Technical crew Kalakuta Republik will travel with 2 technicians. Please provide 3 friendly all round experienced Technicians from the venue. 1 all round technician from the venue stand-by during the performance. SET We may use masking, please do not put borders and legs before our arrival. The scenery will be sent in one small truck. Please check accessibility to loading dock and secure parking. Please Provide black dance carpet on the floor upon arrival. Please make sure, that the stage, side stage and loading dock is empty upon our arrival. Kalakuta Republik Set Contains: 2

1 large Sofa 2 large projection screens that will be fixed on the Wind ups and tubes provided by the theatre. Projection screens are treated with BRANDEX fire retardant impregnation. 30 chairs Disco Ball 4 carpets To be provided by the theatre: Flightcase 40x40 cm black on wheels 3

STAGE DIMENSIONS 12 m wide and 12 m deep and 8m high. Stage dimensions can be discussed with the technical coordinator Rigging To be provided by the theatre: 4

4x Manfrotto s type 087NWB (black)on wheels (height 3m75) 4x Spigot 4x Trussclamb 2x black Alu tubes (6m) to be fixed on the manfrotto s LIGHT To be provided by the theatre: 21 x identical 1Kw PC (with barndoors) 8 x 2Kw PC (with barndoors) 10 x 1Kw Profile 15 12 x Par64 CP62 4 x ACP 6 x Par 36 (pinspots) 8 x light stand or towers. (30cm) 6 x floorstands for par 36 Dimmer circuits: Filters: All lights on separate dimmers. Please check light plot. we will use a light desk (dmx512) from the venue capable to record light cues. VIDEO To be provided by the theatre: 1 beamer at front of house position with at least 10000 ansi lumen with for front projection aprox. 10x 6m with DVI input 2 identical beamers min 5000 ansi lumen with 0.78 fix zoom lens for retro projection. NOTE: For 250 Euro The company can provide the 2 beamers for retro projection. Renting price is normally triple! Contact Technical coordinator for more information. Please provide 2 x HDMI connection from stage to front of house where technical crew is located to run the show. 5

provided by the company: Laptop + Matrox + Millumin. SOUND To be provided by the theatre: One high quality, undistorted and noiseless professional system. (D&B, L acoustics, Meyer, Nexo) Our main concern is to the dispersion of the sound. From each seat of the hall the sound must be of equal volume and constant frequencies bandwidth. The company sound engineer must have total control over the set-up, volume and equalization of the P.A. If there is a balcony, provide an extra flying system with separate amplifiers and delay lines. The mixing desk should be placed in the centre between the left and right PA stacks at 2/3 of the length of the venue, NEVER under balconies and always on the same level as the audience. Audio mixing desk (good quality) analogue or digital with at least 8 input channels and 4 aux sends, 2 main outs and 4bands parametric eq on input channels. in case of analogue desk please provide professional 6 mono graphic eq s on the outputs. Please provide processor to delay FOH or monitors. 4 wedges 12 or 15 inch (L acoustics, D&b, Nexo, Martin) All the same type. No Behringer, Mackie or yamaha please. 1 wireless handheld Mic (sennheiser, shure) with receiver. 2 active di s (radial/bss) provided by the company: Laptop and soundcard. Wardrobe One dresser is required each day of a performance. There should be at least one washing machine and one dryer available in the theatre. The costumes should be washed, dried and ironed. Depending on the facilities, this must happen right after the performance or the next morning. 6

IMPORTANT: AFTER THE FIRST PART PAINT WILL BE ON THE CLOTHES OF THE DANCERS. CLOTHES OF PART 1 MUST BE WASHED DIRECTLY AFTER THE FIRST PART OF THE SHOW. On strike days, this should happen immediately after the performance! The dresser also should fix costumes; in case they break or get damaged during the performance. Upon request, we can provide a list of the costumes and how they need to be treated. Dressing room 2 lockable dressing rooms for the performers with tables and chairs toilets, showers and towels a freezer compartment to store cold packs, within reach of the dressing rooms after the performance All these facilities should be in a non-public area Requested information Medical services: a list of the following should be available in the theatre: dentist, chiropractor, physiotherapist, doctor,... Responsibility Fire The theatre oversees the security of the whole equipment from the moment of arrival at the venue until the moment of departure. One moment a performer is smoking a cigarette on stage. Please check Fire alarm!! Catering Fresh fruit, sandwiches, snacks, salads, juice and water for the set-up day and the day/days of performance/s are highly appreciated. For each day, there should be enough still water available! Transport Our truck will arrive the day before the build-up day. Is it possible to reserve parking space for the whole period of our stay and a free path way 7

to the loading dock? The technical rider is part of the contract and is binding! LIGHT PLOT KALAKUTA REPUBLIK PLEASE NOTE THAT THE 8 X PAR64 ON THE FLOOR ARE AT 30CM HEIGHT. PLEASE PROVIDE STANDS (8) THAT ARE HIGH ENOUGH. 8

106 106 R119 R119 100 195 195 R119 195 195 R119 R119 195 R119 R119 106 106 475 375 340 300 175 100 475 360 290 50 375 160 25 375 425 500 300 450 375 100 100 300 375 450 0-1000 375 425 425 475 PC 1KW barndoor x21 L195 L R119 PC 2KW barndoor x8 L profile 15 38 x10 PAR64 CP62 x12 L L106 floorstands(30cmhigh) x8 PAR 36 x6 floorstands x6 ACP 1KW x4 L119 R114 floorstands x4 FLOOR LIGHTS AND STAGE DIMENTIONS 9

10 848 1275 250 250 400 400 680 680 SCREEN PART 1 SCREEN PART 1 CARPETS KALAKUTA CARPET KALAKUTA Beamer Kalakuta 1 848 1275 250 250 680 680 SCREEN PART 2 SCREEN PART 2 CARPETS KALAKUTA CARPET KALAKUTA Beamer Kalakuta 1