Date: Type: Firm: DLE Family Intelligent LED High Bay Fixtures Project: The DLE intelligent LED fixture family offers unparalleled performance with proven results across a broad range of commercial, industrial, and sporting applications. With marketleading value and efficiency, DLEs are high-performance alternatives to uncontrolled LED, fluorescent, and HID high bay fixtures available in multiple lumen output versions ranging from 11,989 to 55,460 lumens. DLE-12-ST/HV Each fixture is equipped with integrated intelligence enabling wireless communication to Digital Lumens software-based lighting control solutions. Accessible via web and mobile applications, the intuitive software provides comprehensive reporting tools and easy management of lighting systems settings to maximize energy savings, safety, and visual comfort. DLE fixtures feature integrated occupancy and daylight sensors, rotatable light bars, and a variety of optics options to deliver high-quality light and maximum efficiency, flexibility, and control. With adjustable direct/indirect lighting, DLEs are ideal for applications that require lighting uniformity and distribution across both ceilings and workspaces. In addition, DLEs are compatible with Digital Lumens award-winning emergency lighting solution via Battery Backup. DLE-18-ST/HV Product Family Features: Wireless connectivity to the lighting management platforms from Digital Lumens Advanced lighting strategies and dimming capabilities, such as coordinated control and progressive dimming, via software-based controls Direct/indirect lighting distribution options Narrow, Wide, Aisle, and Diffuse optic options Integrated power metering, occupancy, and daylight sensing Compatibility with Battery Backup (BBD43) emergency lighting hardware from Digital Lumens DLE-24-ST/HV DLE-48-ST/HV www.digitallumens.com +1 (617) 723-0 PS E RoHS IP52-22 F Min 122 F Max -30 C Min 50 C Max
SENSING AND CONTROL Onboard Intelligence º º Built-in sensing with data logging º º Energy and fault monitoring º º Protective temperature monitoring and control Native Sensing º º Integrated PIR occupancy sensor º º Integrated daylight sensor Wireless Networking Control Capabilities Dimming ENVIRONMENTAL IP Rating IP52 1 Operating Temperature Maximum Storage Temperature Impact Rating Humidity Photobiological Safety IEEE 802.15.4 Wireless Mesh º º On-demand adjustments via mobile and web applications º º kwh and occupancy logging º º Daylight harvesting º º 0-%, continuous º º PAR1789-compliant with modulation > 1.25 khz Fixture only: -22 to 122 F (-30 to 50 C) Fixture with BBD43 battery backup: 32 to 122 F (0 to 50 C) 122 F (70 C) IK10 Unified Glare Rating 2 20 0-95%, non-condensing Exempt group per IEC 62471 º º L70 (18K): 103,000 hours Lumen Maintenance º º L70 calculated: 121,000 hours 3,4 º º L80 calculated: 78,000 hours º º L calculated: 41,000 hours Power Factor 0.9 min Surge Protection º º Per IEC 61547 º º 1 kv line-line / 2 kv line-earth Wiring Mounting Options Fixture Frame and Power Enclosure º º WAGO Winsta modular socket; º º Direct wiring with 0.5 in (1.3 cm) trade-size knockout 5 Aircraft Cable or Fixed Mount º º PC / ABS polymer and anodized aluminum º º Zinc-plated steel Optic Material º º Optical grade PMMA º º Optical grade PC option (diffuse optic) Optic Options Narrow, Wide, Aisle, or Diffuse WARRANTY Fixture Warranty Battery Backup Warranty ACCESSORIES DHHAS DHHSO DHHRM DLEDK DLESM 6 DDWPL BBD43UL 7 BBD43CE 7 POWER CORDS North America: Without plugs: DWUL1 DWUL2 DWUH1 DWUH2 DWNM1 DWNM2 With plugs: DCUL10- (10 ft) or DCUL20- (20 ft) Europe/International: Without plugs: DWCE1 DWCE2 With plugs: DCCE320 DCCE620 10-Year Limited 5-Year Limited Aircraft Cable Hanging Hardware DLE Hanging Hardware Standoff Fixed Mount Hanging Hardware (2x required for DLE-48 fixtures) DLE Tabletop Demo Kit with Hard Case (fixture not included) PIR Sensor Mask, 10-pack DLE Direct Wiring Plug, Fixture Battery Backup (North America) Battery Backup (Europe) 10 ft whip, 300 V rated cable (UL, cul) 20 ft whip, 300 V rated cable (UL, cul) 10 ft whip, 600 V rated cable (UL, cul) 20 ft whip, 600 V rated cable (UL, cul) 10 ft whip, 300 V rated cable (UL-NOM) 20 ft whip, 300 V rated cable (UL-NOM) 01 NEMA L5-15 125 V 02 NEMA L5-20 125 V 03 NEMA L6-15 250 V 04 NEMA L6-20 250 V 05 NEMA L7-15 277 V 06 NEMA L7-20 277 V 07 NEMA L8-20 480 V 08 NEMA L24-20 347 V 3 m whip (CE) 6 m whip (CE) 3 m (Schneider Electric Canalis KBC16DCF21 (CE); 220-240 V) 6 m (Schneider Electric Canalis KBC16DCF21 (CE); 220-240 V) 2 Digital Lumens
DLE-12-ST/HV 8 Color Temperature 9 5,000 K CCT 4,000 K CCT Lumen Output (nominal) 13,446 lm 11,989 lm Power Consumption (nominal) 103 W 106 W 22.0 in (55.9 cm) Efficacy 10 lm/w 113 lm/w CRI 70 min, 72 typ 80 min, 82 typ Input Ratings 11 Standard Voltage (ST): -277 VAC, 50/60 Hz High Voltage (HV): 347-480 VAC, 50/60 Hz 1 (34.3 cm) (8.9 cm) ADDITIONAL FIXTURE OPTIONS: Battery Backup (BBD43) CERTIFICATION DLE-12 Certifications Fixture only: 3.5 x 13.5 x 22.0 in (8.9 x 34.3 x 55.9 cm) Fixture + BBD43: 3.5 x 13.5 x 23.4 in (8.9 x 34.3 x 59.5 cm) Fixture only: 9.5 lbs (4.3 kg) Fixture + BBD43: 11.5 lbs (5.2 kg) UL, cul, UL-NOM (Standard Voltage only), CE, FCC Part 15 Class B, CISPR 15, DLC Premium, PSE (Standard Voltage only), VDE-ENEC, ST COA, CCC, TISI, SII Note: Individual fixture certifications may vary depending on color temperature and/or voltage type. DLE-18-ST/HV 8 Color Temperature 9 5,000 K CCT 4,000 K CCT Lumen Output (nominal) 20,242 lm 18,127 lm Power Consumption (nominal) 155 W W 22.0 in (55.9 cm) Efficacy 10 lm/w 113 lm/w CRI 70 min, 72 typ 80 min, 82 typ Input Ratings 11 Standard Voltage (ST): -277 VAC, 50/60 Hz High Voltage (HV): 347-480 VAC, 50/60 Hz 18.5 in (47.0 cm) (8.9 cm) ADDITIONAL FIXTURE OPTIONS: Battery Backup (BBD43) CERTIFICATION DLE-18 Certifications Fixture only: 3.5 x 18.5 x 22.0 in (8.9 x 47.0 x 55.9 cm) Fixture + (2x)BBD43: 3.5 x 18.5 x 23.4 in (8.9 x 47.0 x 59.5 cm) Fixture only: 12.0 lbs (5.4 kg) Fixture + (2x)BBD43: 13.9 lbs (6.3 kg) UL, cul, UL-NOM (Standard Voltage only), FCC Part 15 Class B, CISPR 15, DLC Premium, CE, PSE (Standard Voltage only), ST COA, CCC, TISI, SII Note: Individual fixture certifications may vary depending on color temperature and/or voltage type. 3 Digital Lumens
DLE-24-ST/HV 8 Color Temperature 9 5,000 K CCT 4,000 K CCT Lumen Output (nominal) 27,036 lm 22,932 lm Power Consumption (nominal) 211 W 208 W 22.0 in (55.9 cm) Efficacy 10 128 lm/w lm/w CRI 70 min, 72 typ 80 min, 82 typ Input Ratings 11 Standard Voltage (ST): -277 VAC, 50/60 Hz High Voltage (HV): 347-480 VAC, 50/60 Hz 21.3 in (54.1 cm) (8.9 cm) ADDITIONAL FIXTURE OPTIONS: Uplighting Battery Backup (BBD43) CERTIFICATION DLE-24 Certifications Fixture only: 3.5 x 21.2 x 22.0 in (8.9 x 53.8 x 55.9 cm) Fixture + BBD43: 3.5 x 21.2 x 23.4 in (8.9 x 53.8 x 59.5 cm) Fixture only: 14.6 lbs (6.6 kg) Fixture + BBD43: 16.5 lbs (7.5 kg) UL, cul, UL-NOM (Standard Voltage only), CE, FCC Part 15 Class B, CISPR 15, DLC Premium, PSE (Standard Voltage only), VDE-ENEC, ST COA, CCC, TISI, SII Note: Individual fixture certifications may vary depending on color temperature and/or voltage type. DLE-48-ST/HV 8 41.0 in (104.2 cm) Color Temperature 9 Lumen Output (nominal) Power Consumption (nominal) Efficacy 10 CRI Input Ratings 11 5,000 Kelvin CCT 55,460 lm 423 W 131 lm/w 70 min, 72 typ Standard Voltage (ST): -277 VAC, 50/60 Hz High Voltage (HV): 347-480 VAC, 50/60 Hz Fixture only: 3.5 x 21.3 x 41.0 in (8.9 x 53.8 x 104.2 cm) Fixture + (2x)BBD43: 3.5 x 21.3 x 44.4 in (8.9 x 53.8 x 112.7 cm) Fixture only: 28.7 lbs (13.0 kg) Fixture + (2x)BBD43: 32.6 lbs (14.8 kg) 21.3 in (54.1 cm) (8.9 cm) CERTIFICATION DLE-48 Certifications UL, cul, UL-NOM (Standard Voltage only), FCC Part 15 Class B, CISPR 15, DLC Premium, CE, PSE (Standard Voltage only), ST COA, CCC, TISI, SII Note: Individual fixture certifications may vary depending on color temperature and/or voltage type. ADDITIONAL FIXTURE OPTIONS: Uplighting Battery Backup (BBD43) Note: (2x) BBD43 units required per DLE-48 fixture. 4 Digital Lumens
DE-RATING CHART The lumen output values on the following pages reflect those of Wide optic fixtures. To calculate an approximate value for Aisle, Narrow, and Diffuse optic lumen outputs, multiply the listed lumen output by the de-rating value below: AISLE DIFFUSE NARROW 0.97 0.96 0.93 POLAR CANDELA DISTRIBUTION Fixed Axis Adjustable Axis DLE-12 DLE-18 DLE-24 DLE-48 NARROW OPTIC 10-10 20-0 -20 20-0 -0-20 20-0 -0-20 WIDE OPTIC 0-0 0-0 -0 0-0 -0-0 0-0 -0-0 DIFFUSE OPTIC 0-0 0-0 -0 0-0 -0-0 0-0 -0-0 AISLE OPTIC 40-40 40-0 -40 40-0 -0-40 SPACING CRITERIA DLE-12 DLE-18 DLE-24 DLE-48 Optic Type Fixed / Adjustable Fixed / Adjustable Fixed / Adjustable Fixed / Adjustable Narrow 0.50 / 1.40 0.48 / 1.02 0.56 / 2.22.52 /.80 Wide 1.32 / 1.32 1.30 / 1.32 1.32 / 1.30 1.32 / 1.32 Diffuse 1.24 / 1.28 1.24 / 1.30 1.24 / 1.28 1.24 / 1.30 Aisle 0.72 / 2.32 0.42 / 1.48 0.44 / 1.72 5 Digital Lumens
DLE Uplighting Improve aesthetics, visual comfort, and safety by reducing glare and ceiling/floor contrast Independently aimable light bars rotate between 0 and Ordering Information Available for DLE-24 and DLE-48 fixtures only. Battery Backup (BBD43) SPECIFICATIONS Runtime (UL) minutes; (CE) minutes Operating Temperature 32 to 122 F (0 to 50 C) Battery Type NiMH Input 42 VDC, ma Output 42 VDC, 500 ma IP Rating IP52 3.5 x 11.7 x 2.9 in (8.3 x 29.8 x 7.3 cm) 2.0 lbs (0.9 kg) BBD43 Certifications UL 924 (UL, cul, UL-NOM), CE BBD43 Warranty 5-Year Limited (8.3 cm) 11.7 in (29.8 cm) DLE-48 ORDERING INFORMATION: Available to order for DLE fixtures that are BBD43-compliant. DLE-48 fixtures require (2x) BBD43 units per fixture. DLE-18 DLE-12 BBD43 (1) Light Bar (1) DLE-24 BBD43 BBD43 Light Bar 2.9 in (7.3 cm) BBD43 Light Bar Light Bar Light Bar (2) 6 Digital Lumens BBD43 (2)
Hanging Hardware Standard Aircraft Cable (DHHAS) ORDERING INFORMATION: Available to order for DLE-12, DLE-18, DLE-24, and DLE-48 fixtures. One DHHAS includes hanging hardware for five fixtures (10x units). One DHHSO includes hanging hardware for 50 fixtures (x units). 60 Max. Hanging Hardware Standoff (DHHOS) Fixed Mount (DHHRM) ORDERING INFORMATION: One DHHRM includes five (5x) units of hanging hardware. DLE + FIXED MOUNT HARDWARE DIMENSIONS: ø.3 in 7 mm 3.3 in 85 mm 2.8 in 70 mm 1.4 in 35 mm ø 1.1 in 28 mm 2.4 in 60 mm 3.4 in 85 mm 4.0 in 102 mm 3.3 in 85 mm.6 in 16 mm 7.8 in 196 mm 8.7 in 220 mm.5 in 12 mm DLE-12/18/24 8.8 in (22.3 cm) DLE-48 7 Digital Lumens
DLE Fixture Ordering Information The table below provides guidelines for encoding item numbers when ordering DLE fixtures. Select a fixture type (lumen output), voltage, optic, and CRI/CCT, and then use the character codes (in bold) when ordering. Note: For short/standard leadtimes, select options in bold. FIXTURE PREFIX VOLTAGE OPTIC CRI/CCT -ST Standard Voltage -N Narrow -843 -HV High Voltage -W Wide -753 -A Aisle 4000 K CCT, BBD43-compatible, 5000 K CCT, BBD43-compatible, -D Diffuse 12 FIXTURE PREFIX VOLTAGE OPTIC CRI/CCT -ST Standard Voltage -N Narrow -844 -HV High Voltage -W Wide -754 -A Aisle 4000 K CCT, BBD43-compatible, 5000 K CCT, BBD43-compatible, -D Diffuse 12 FIXTURE PREFIX VOLTAGE OPTIC CRI/CCT -ST Standard Voltage -N Narrow -754 5000 K CCT, BBD43-compatible, DLE-12- or DLE-18- DLE-24- DLE-48- -HV High Voltage -W Wide -D Diffuse 12 1! Clean with mild soap and water only.! Maintain 10 ft (3 m) setback from walls open to exterior. 2 Calculated in nominal application environment. 3 Per LM-79-08 test methods. 4 Projected based on TM-21 data. L70 = Time to 70% lumen maintenance. For details, refer to the Statement of Lumen Maintenance. 5 Requires DDWPL (DLE Direct Wiring Plug). Refer to the DLE Installation Instructions for more information. 6 Fixtures with Wide or Diffuse optics, as well as all DLE-48 fixtures ship without sensor masks. 7 Requires BBD43-compatible fixtures. DLE-48 requires two (2x) BBD43 units per fixture. Refer to individual product specifications for details. 8 High Voltage fixtures (HV) available in North America only. 9 Nominal CCT, as defined by ANSI C78.377-2008. 10 Efficacy values vary with optic option. See DLC QPL for variant details. 11 Input ratings may vary for international certifications. 12 Note that Daylight Harvesting is not operable by a fixture with Diffuse optics, unless DLE Daylight Harvesting Shield is attached. www.digitallumens.com 374 Congress Street, Suite 600 Boston, MA USA 02210 +1 (617) 723-0 All Rights Reserved 2010-2017 Digital Lumens Incorporated Subject to change without notice. DOC-000318-00 Rev M 10-17