Surface Mount Installation Manual

Similar documents
Surface Mount Installation Manual

A Division of Impact Lighting STAR PANEL INSTALLATION MANUAL

HDMI Over IP Extender Kit - 4K

HDMI over IP Extender Kit with Video Wall Support p

PRODUCT MANUAL. Chroma Flow PRO RGB LED Controller. and Receiver. Product Description. Main Functions: This manual reviews: Receiver.

White Only. Twinkle Stars INCLUDED IN ALL KITS: 12 VOLT POWER SUPPLY 3 DRILL BITS TEMPLATE REFERENCE INCLUDED IN BELOW MODULES TL-FBK TL-CLB-FWK

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

INSTALLATION MANUAL. ION Series FIBER OPTIC ILLUMINATOR IP67 OUTDOOR RATED

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages)

TeamWork Kits Installation Guide

TeamWork Installation Guide

INSTALLATION INSTRUCTIONS FOR

TV Lift System Model CL-65 Installation Instructions

Multi-Key v2.4 Multi-Function Amplifier Keying Interface

INPUT OUTPUT GAIN DELAY. Hue Candela Strobe Controller. Hue Candela s STROBE CONTROLLER. Front Panel Actual Size 7 ¼ By 4 ¾ POWER. msec SEC 10 1.

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

DVI DL Super Booster Plus EXT-DVI-141DLBP. User Manual

DD E SIG N E D & E N GIN EE R E. Holman Garden Lights App Instruction Manual. Android Android manual

NewScope-7A Operating Manual

CAT EXT-CAT USER MANUAL

Automotive 72 Exterior Smart Lighting Kit

PRODUCT MANUAL. DMX BOSS Wi-Fi Controller. Product Description

MOTION CONTROL SYSTEMS, MSC SERIES AUGUST 1998 EFC-240X ENCODER/FIBER OPTIC CONVERTER INSTRUCTION BOOK

Breathe. Relax. Here Are the Most Commonly Asked Questions and Concerns About Setting Up and Programming the SurroundBar 3000.

Instruction Manual for Electronic Blowers and Flashboards

TIMETRAX SYNC RF WIRELESS DIGITAL CLOCK Installation Instructions

4X1 Gefen TV Switcher GTV-HDMI N. User Manual

Electric Motorized Projection Screen PowerMax Tension Series

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

Cellular Signal Booster

EPIC RS232 ADVANCED. Specifications External power supply - (power supply sold seperately)

ICS Digital Menu. Installation Guide Version 1.1

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

TROV TROUBLE SHOOTING GUIDE. A comprehensive trouble shooting guide for TROV

1:8 CAT5 Distribution Amplifier

Cellular Signal Booster

Q-TV2. User Manual. for Screens

INSTRUCTION MANUAL. Made in the U.S.A. by USA Dance Floor. Copyright 2017 USA Dance Floor, LLC

HC20 Healthcare Kit Installation Instructions

MS2540 Current Loop Receiver with RS485 Communication

HDMI over CAT5 HDBaseT Extender - Power over Cable - Ultra HD 4K

Cyclo Series. user manual. MartinArchitectural

OWNER'S MANUAL KIT INCLUDES. 3M VHB Mounting Pad Mounting Hardware PART # 40040

HDMI over CAT5 HDBaseT Extender - 4K

PROJECT DATE LENS SF FLANGE FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Pixel LED SPI Digital Controller

4x4 Component Matrix over CAT-5

CAT Extender. EXT-CAT User Manual.

LeRIBSS MTC MANUAL. Issue #1. March, MTC Control Unit Definitions, Information and Specifications. MTC Control Unit Electronic Schematics

EPIC'S RS232 PRO. Specifications External power supply - (power supply sold seperately) Output: 8-24V DC (depends on input) DC Per Channel

Building the BX24-AHT

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

Zero-G. Owner s Manual. External Mount INSTALLERS: PLEASE LEAVE THIS MANUAL WITH THE OWNER.

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

Model#: IN-DI2MIRF 2MP Indoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

OSD. EXECUTIVE / MiniDome USERS MANUAL. USING THE MOTOSAT DISH POINTING SYSTEM EXECUTIVE / MiniDome OSD

Nanoleaf Light Panels

Evolution Digital HD Set-Top Box Important Safety Instructions

HDMI over CAT5 HDBaseT Extender - RS232 - IR - Ultra HD 4K ft (100m)

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

4X1 Gefen TV Switcher. GTV-HDMI N. User Manual

E4200 Antenna Installation Instructions: 1. Soldering required (here is the list of tools you will need)

USER MANUAL. GOLDMUND LOGOS 1N-2N SPEAKER SYSTEM Active Speaker

Configuration Vestas VMP3500

SCIR. Infrared Illuminator Powerful Indoor/Outdoor IR Spotlight SCIR

NEO-STB-0004 Neo-Flash 300 RGB User Manual

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

User Manual 15" LCD Open frame SAW Touch Monitor KOT-0150US-SA4W. Table of Contents

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

ModWright Instruments, Inc. PH 150 Tube Phono Stage Owner s Manual

User Guide SiriUS ConneCt tuner

Important Safety & Warning Precautions

Starling Tab-Tension 2 Series

MAKE AN RGB CONTROL KNOB.

RADIO FREQUENCY SYSTEMS

HD Digital Set-Top Box Quick Start Guide

Trim Diagram Da Vinci Chandelier DV1818ALED

User Manual. HDBaseT Wallplate Transmitter over Cat6/6A. Front View Panduit Dr, Tinley Park, IL (708)

For warranty service, please contact Microframe at: A technician will gladly assist you.

DIGITAL SWITCHERS 2100 SERIES

Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide

Satellite Dish Installation Manual (Ver. 2) 1

DX-10 tm Digital Interface User s Guide

80 Watt LED DMX Illuminator

Optical Distribution Box 300 Installation Guide. Version : R0.0

ISE, Inc Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440) B Long Ranger Timer

FD-128D FiberDriver - DMX Fiber Optic Illuminator

PRODUCT DATA SHEET FEATURES

Special Applications Modules

2002 Martin Professional A/S, Denmark.

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

SBL /SBLG Series Wireless Clock

Lumencove Family. The highest quality light from the tightest spaces

Documentation VFD clock 8 a clock

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM

What is SnoCam? SnoCam Installation Guide. SolarVu

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

INSTALLATION INSTRUCTIONS

Transcription:

Surface Mount Installation Manual TM

WELCOME TO THE WORLD OF FIBER OPTIC STAR LIGHTS. Your package should include the following: Acoustical fiber optic panels Mounting anchors Low voltage jumper cables Lead wire(s) RCA Lead wire(s) if controlled by RS232, and RCA (serial) jumpers as well if controlled via RS232 Hex tools poker tool Anchors template 12V power supply Cove lighting spacers (optional not always used. Spacers are used with the Thin-glow LED system.)* * Some installers use spacers for standard installation requireing more room for wires. Note: Sometimes there will be more than one lead wire and sometimes the wire(s) will already be attached to the power supply. POWER SPECIFICATIONS: Each panel draws 12V and 2.5W, or 0.2 amps max. Note: Some panels will come with a shooting star, which contain two (2) CineStarPanel Board light sources and will increase the panel another 2.5W, for a total of 5W. TIP: Put latex gloves on to keep panels clean when handling. INSTALLATION (with 2 people using a stepladder): Square up the room. A room may look square, but it doesn t mean that it is square. Measure twice since all the panels are aligned off of the first panel. It s alignment in the room is critical. Being just a little out of square with the first panel could result in being way out of square when you get to the end of the room. Take your time squaring up the first panel. Using masking tape, pencil marks, and chalk lines will assist you in keeping the installation square and true. Locate where your first panel will be installed. RUNNING THE POWER: Based on site conditions and project design, there will generally be two options for power. The recommended way is to use a Remote Driver and pre-install a CineStarPanel Leader Cable, or pre-wire an 18 AWG wire. The second and alternate way is using the Embedded Driver in the ceiling. (As always, check and observe local building codes.) TIP: After you finish running the power, after lead wires run, test every panel before it goes up, by plugging lead wire to the LED board, located in the center of the panel. OPTION 1: REMOTE DRIVER (RECOMMENDED METHOD) The power supply has connectors for a power cable for the input of the line voltage. The selected outlet for powering the Driver should be controlled from a remote switch, or control system. Locate the Driver in a proper equipment area that is accessible and within 50 feet of the first ceiling panel (generally in the center of the ceiling.) At this point, connect the Star Panel Leader Cable and start daisy chaining the panels together, using the supplied Jumper Cables. Your leader cable should not be longer than 50 feet. Consult with a CineStarPanel manufacturer if a longer leader cable is required. -1-

OPTION2: EMBEDDED DRIVER Only a licensed electrician should embed the Driver into the ceiling. It may be necessary to install a Driver into an approved electrical enclosure where the line voltage is already located in the ceiling, and running new low voltage wire is not an option. This may be more common in existing older home and retro fits. The Driver is a line voltage device and will require access to it (according to most electrical codes); therefore, a cut out in the panel will be required to access the Driver. Use the CineStarPanel Cut Out Kit (optional) to mark and cut the panel. (Check and observe local building codes.) TIP: After you finish installation of the power supply and lead wire run, test every panel before it goes up, by plugging lead wire to LED board, located in the center of the panel. Note: If your system comes with shooting star, a moon, meteor shower etc. Please confirm placement of the effects on the ceiling. MOUNTING THE FIRST PANEL TIP: You can use a paint brush extension (available at most hardware stores) to hold the panel in place. Place the first panel on the ceiling and square in its proper orientation. (This should be performed by at least two people) Push the awl (poker tool) through the center of the round stickers to make an indent in the ceiling. This is done from the finished fabric side of the panel. Once all mounting points are marked on the ceiling, remove the panel. You may use our templates to guide you, please see page 5. TIP: While installing the panels, keep the plastic covers of the un-installed panels on so dust doesn t get on them (especially in construction areas.) See Chart A and Chart B STANDARD PANEL CHART (POWER CHART) A POWER NO. OF SUPPLY PANELS 25W 10 panels 45W 18 panels 60W 24 panels 80W 32 panels 100W 40 panels 150W 60 panels 200 W 80 panels 250W 100 panels 300W 120 panels EXAMPLE OF 25W POWER SUPPLY PANEL WIRING B *If you have more than 120 panels, please contact us for assistance. INSTALLATION STEPS: Step 1. Position panel. Mark its location. Panel Extension optional: sold seperately Position panel. Mark its location. -2-

Step 2. Put masking tape on panel face at anchor locations (optional). Position template: push scratch awl (poker tool) through panel at template marking hole. Indent wallboard behind panel. Note: to mark harder wall material, i.e. concrete block, after marking the panel with the scratch awl, put a common nail in the hole and tap with it. Template For more details on marking the Star Panel please view page.7 After Step 2, remove panel Step 3. Screw panel anchors to wall at pre-marked locations. (Consult manufacturer for recommended fasteners to use with anchors. Note: do not over-tighten. Anchors should be hand tight and able to turn on screw shaft. Step 4. Push hex insert firmly into anchor body. 4.1 Push pointed hex driver through panel to engage panel anchors. -3-

TM TM Step 5. Re-position panel. Connect the lead wire to the LED board of the first panel Note: fully engage hex driver with metal insert before turning. Step 6. Turn Feature Presentaions Star panel anchors counter-clockwise (left) while pushing panel towards wall. Remove masking tape. Lightly rub fabric to hide hole locations. Note: 1 to 2 turns, do not over-tighten. Note: Our panel anchors have been tested to have a pullout strength exceeding 45 lb. in standard 6 lb./ft. 3 fiberglass insulation board. INSTALLING ADDITIONAL PANELS Leave the jumper hanging off the side of the first panel so you can connect the next panel. Because of the flat design of the Jumper Cable plugs, you can sandwich the Jumper Cables between the ceiling and panel, or run them along the 2 light cove on the back of all Surface Mount Panels. You may find that using white gaffers tape, glue dots, or double sided tape helpful in organizing the Jumper Cables during installation. Up to 12 CineStarPanels can be connected together in any configuration per lead wire. If your installation requires more than 12 Star Panels, then add an additional Leader Cable. The total quantity of panel depends on power supply size. NOTE: See Power Chart on Page 3 for power supply recommendation. Multiple lead wires may be necessary with one power supply (not included in package). -4-

STAR PANEL 8 IN & 6 IN ANCHOR TEMPLATE MAY BE USED A S A PROTRACTOR ON PANEL. IF THERE IS A FIBER OR OBSTRUCTION YOU MAY GO AROUND IT AND SCREW IN ANCHOR. USE YOUR JUDGEMENT. Note: Some install anchores at 4 inches away, please use your discretion. STEP 1 A) Place anchor template on any corner of the Star Panel and mark the area at 8 inch for anchor installation B) Place anchor template on any side of the Star Panel and mark the area at 6 inch for anchor installation STEP 2 Poke a hole with the Poker tool on the marked areas. STEP 3 Fasten the anchor to the ceiling; use a hex tool to turn anchor to adhere the star panel to the ceiling. * Used also for marking speaker and downlight light areas on the Star Panel. -5-

IF USING CUT-OUT TEMPLATE (NOT INCLUDED IN STAR CEILING SYSTEM) This template is a universal marking guide and cut-out stencil used for marking the center of a down-light, vent, speaker, or any hole that needs to be marked and cut in a CineStarPanel. Secure the large thumbtack in the center of the Cut-out Template using double-sided tape. Then use double sided tape or thumbtacks to hold the template centered on the ceiling over the opening or area you need to cut out. Properly align the panel and push it up into the thumbtack(s) (Thumbtacks do not come in the package.) Take the panel down, note the location of the thumbtack mark on the back of the panel. Mark the location of the hole on the fabric face of the panel. Now flip the panel over so it is fabric side up. Place the template centered over the hole and insert the awl. Now you have the template so that it rotates around the awl. Note: The circumference of the hole that is required (this hole should be slightly larger than what is required for the fixture opening, but smaller than the fixtures trim ring.) Place the hot knife in the appropriate slot on the template, and slowly rotate the hot knife and template all the way around the cut and cinch the fabric. Remove the awl and template, peel off the fabric circle and use the serrated knife to cut the two inches of insulation. Your perfectly located hole is done. Pulsar Star Board (2400 8 N 1) Comd. Mode ION Star Boards On IOFF Star Boards Off P0 Scintillation P1 All on 50% P2 All On 25% P3 Meteor Shower P4 Sparkle P5 Sparkle Fast P6 Sparkle Really Fast P7 Shooting Star Off P8 Shooting Star 1 Minute P9 Shooting Star 2 Minutes P10 Shooting Star 5 Minutes P11 Shooting Star 10 Minutes P12 Shooting Star 1 Second P13 Rain Shower P14 Random Strobe P15 All On 100%! Shooting Star Trigger @ Meteor Shower Trigger P$ Stop Shooting Star and Meteor Shower P$M Stop only Meteor Shower P$S Stop Only Shooting Star P% Resume Shooting Star and Meteor Shower -6-

PULSAR BOARD RS232 COMMANDS AND DIP SWITCHES Pulsar_II model allows a variety of effects including Star Effects ( sparkle, scitilation, rain,strobe,etc) and special effects (shooting star, meteor shower). The Dip Switch sets the program (program 3 setting is shown in picture): PROGRAM: PROGRAM NUMBER SWITCH 1 SWITCH 2 SWITCH 3 SWITCH 4 Scintillation 0 DOWN DOWN DOWN DOWN All on 50% 1 UP DOWN DOWN DOWN All on 25% 2 DOWN UP DOWN DOWN2 Meteor shower 3 UP UP DOWN DOWN Sparkle 4 DOWN DOWN UP DOWN Sparkle Fast 5 UP DOWN UP DOWN Sparkle really Fast 6 DOWN UP UP DOWN Shooting star Off 7 UP UP UP DOWN Shooting star (1 minute) 8 DOWN DOWN DOWN UP Shooting star (2 minutes) 9 UP DOWN DOWN UP Shooting star (5 minutes) 10 DOWN UP DOWN UP Shooting star (10 minutes) 11 UP UP DOWN UP Shooting star (1 second) 12 DOWN DOWN UP UP Rain shower 13 UP DOWN UP UP Random strobe 14 DOWN UP UP UP All on 100% 15 UP UP UP UP Other program numbers Available from RS-232 (not from dip switch): Program 16 return current program to the DIP switch setting Program 17 use Individual LEDs set/reset setting (see the = and - commands) Program 18 All Off (note: only affects pulsar boards use IOFF Instead to turn off all boards Note: All commands need to be followed by a carriage return (/r) and not a new line. -7-

and return to last program) Notes: DIP switch can be changed while board is powered. Use Program 7 (Shooting star off) for downstream boards in shooting star effect Modes of Operation: There are three modes of operation based on the DIP switch setting, 2 modes are special effects, and normal mode is Star Effect mode Special Effects: Meteor Shower (Program 3) Shooting star effect (Programs 7 to 12) Star Effect: All other programs are star effect mode! Communications for program number 0 to 15 only affect the boards with the same modes of operation. That is shooting star programs only affect the boards with the DIP switch set to shooting star (programs 7 to 12). Star effect programs only affect boards not set to special effects.! To Setup for shooting star effect with multiple boards: 1) Set Switch for FIRST shooting star board for shooting star mode (delay between shooting star) as desired. Downstream boards should be set to program 7 (shooting star off - UP UP UP DOWN) as they are controlled from the first board. 2) Connect The communications wire as follows: First Board in shooting star COMM OUT (White jack) connection connects to second board COMM IN (Black Jack) connection, Second board COMM OUT (White Jack)connects to COMM IN (Black Jack) connection: Serial Communications Serial Communications (RS232) is 2400 baud, 8 bits, no parity, 1 stop bit Computer Pin 3 on DB9 = TX = Center pin on black comm jack on pulsar II Computer Pin 5 on DB9 = Common= outside(shield) on black comm jack on pulsar II First Board 2nd Board (Downstream) -8-

All commands for pulsar II start with a character P and end with a carriage return (Enter key) Global commands (ION and OFF) affect both pulsar board AND Thin glow (RGB) on samecommunications line. Commands can be either global or addressed to a specific board in the string. Syntax of commands P(program) <Enter> (this is a global command to all pulsar II boards) or P (board)(program) <Enter> (this addresses a specific board) Where: (program) is the program number (0-15 see table above) (board) is the board in the chain (A-Z) in order of connection <Enter> is a carriage return Examples of common commands: To Turn system OFF (*) This will make all Impact lighting boards turn off(global) Enter Command: IOFF To Turn system back ON (*) This will make all Impact lighting boards turn on to the last mode/program/speed Enter Command: ION * - NOTE: these commands will affect all Impact Lighting boards (both pulsar and Thin glow (RGB) boards). To Change to sparkle mode to fast This will make all pulsar boards (boards set for scintillation or sparkle) set for go to fast sparkle (shimmer) effect (global) Enter Command: P6 To Change to scintillation mode This will make all pulsar boards (boards set for scintillation or sparkle) set for go to scintillation effect (global) Enter Command: P0 To Change to steady (no sparkle or scintillation) This will make all pulsar boards (boards with DIP switch set for scintillation or sparkle) set for go to scintillation effect (global) Enter Command: P2 Trigger shooting star Now Exclamation point is used to communicate between board in shooting star configuration. This will cause boards to start a shooting star effect as soon as received (and reset timing for next shooting star). Enter Command:! Note: This will also trigger boards set to program 7 (shooting star off). If you only want shooting star to be triggered from communications, set all shooting star board DIP switch to program 7 and issue! When required. Note: This is a 1 character command (intended to be fast). Carriage return is not required. -9-

Trigger meteor shower Now This will cause boards to start a meteor effect as soon as received (This allow meteor shower effect to be synchronized between boards.) Enter Command: @ Note: This is a 1 character command (intended to be fast). Carriage return is not required.! To Change to shooting star mode to every 1 minute This will make all pulsar boards (boards with DIP switch set for shooting star) go to shooting star effect. Enter Command: P8 To Change to shooting star mode to every 10 minutes This will make all pulsar boards (boards with DIP switch set for shooting star ) go to shooting star effect. Enter Command: P11 To Stop meteor shower AND shooting star This will make all pulsar boards (boards with DIP switch set for shooting star or meteor effect) to stop effect Enter Command (dolar sign): P$ To Stop ONLY meteor shower This will make all pulsar boards (boards with DIP switch set for shooting star or meteor effect) to stop effect Enter Command: P$M To Stop ONLY shooting star effect This will make all pulsar boards (boards with DIP switch set for shooting star or meteor effect) to stop effect Enter Command: P$S To Resume meteor shower and shooting star This will make all pulsar boards (boards with DIP switch set for shooting star or meteor effect) to resume last effect Enter Command: P% Advanced Commands Sparkle Speed Sparkle/meteor speed is controlled via Speed command 1-9 9=slowest, 1 = fast (NOTE: this is value is saved in memory and restored when powered up). The meteor speed controls the time between meteor showers (5 minutes is default) P#(speed) This will make the sparkle effect go slow (program 4-6) Enter: P#1 Meteor Speed Sparkle/meteor speed is controlled via Speed command 1-9 9=slowest, 1 = fast (NOTE: this is value is saved in memory and restored when powered up). The meteor speed controls the time between meteor showers (5 minutes is default)! P^(speed) This will make the meteor shower happen every 20 minutes minute (up to 250 minutes) Enter: P^20 Individual LED control Individual LEDs may be commanded on bright, on dim, or /off when in program 17 Bright LED: P=xxx where xxx = decimal value to led to illuminate bright (0 to 255) Dim LED: P-xxx where xxx = decimal value to led to illuminate dim (0 to 255) -10-

Examples: This will turn off the LEDS Enter: P17 This will turn on the first LEDS on bright Enter: P=1 This will turn on four LEDS on dim (all boards) Enter: P-15 This will turn on top LED (dim) on first board (Board A) Enter: PA-128 Specifications: Power in: DC 8V to 24V DC 0.2 Amp max draw (0.84watt draw typical all LEDs on at 12 volts) polarity and fuse protected input Output: Pulsar (white LEDs) 20 milliamps per LED. (3.2Volts / 0.064 watt per LED, total all LEDs0.512 watts) RGB up to 4 amps each output peak (on SV2, SV3). Communications: Serial 2400 baud, 5V 12V signaling -11-

WIRING PANELS (STARS ONLY) STANDARD CONFIGURATION STAR PANEL STAR PANELS 2ft. x 2ft. Panel 2ft. x 4ft. Panel 4ft. x 4ft. Panel 4ft. x 8ft. Panel OPTION1A: STANDARD STAR PANEL OPTION 1B: STANDARD STAR PANEL WITH TOUCH CONTROLLER W/ STARY NIGHT EFFECTS W/ STARY NIGHT EFFECTS - + - + TOUCH CONTROLLER COMMUNICATION [CAD 5 CABLE] N L +V -V DIN RAIL 12V/24V N L +V -V DIN RAIL 12V/24V

N L +V -V ipa d ipa d 3G 4:08 PM Mail Weather Facebook WIRING PANELS (STARS) OPTION 2: RS-232 TO STAR PANEL NEXT PANEL RS-232 COMMUNICATION [CAD 5 CABLE] - + 100-220V N L +V -V DIN RAIL 12V/24V OPTION 3: TABLETS (APPLE OR ANDROID] TO STAR PANEL - + EP-W2SL 100-220V IPAD IPAD MINI IPHONE ANDROID NEXXUS DIN RAIL 12V/24V

WIRING PANELS VIA RF CONTROLLER WITH STARS AND COVE EFFECTS OPTION 1: RF REMOTE, SHOOTING STAR W/ COVE EFFECT NEXT PANEL W/ SHOOTING STAR EFFECT COLOR CHANGING COVE (4 WIRES OR SINGLE COLOR COVE (2 WIRES) W/ STARY NIGHT EFFECTS RF REMOTE CONTROLLER (COVE / STARS) 100-220V N L +V -V DIN RAIL 12V/24V

WIRING PANELS VIA IR CONTROLLER OPTION 2: IR CONTROLLER, STAR PANELS & COVE LIGHTING NEXT PANEL SHOOTING STAR COLOR CHANGING COVE (4 WIRES OR SINGLE COLOR COVE (2 WIRES) W/ STARY NIGHT EFFECTS IR REMOTE CONTROLLER IR CODES 100-220V N L +V -V DIN RAIL 12V/24V

WIRING PANELS VIA RS232 CONTROLLER OPTION 3: RS-232 CONTROLLER, STAR PANELS & COVE LIGHTING NEXT PANEL SHOOTING STAR COLOR CHANGING COVE (4 WIRES OR SINGLE COLOR COVE (2 WIRES) W/ STARY NIGHT EFFECTS RS-232 FOR COVE LED ONLY RS-232 100-220V DIN RAIL 12V/24V N L +V -V

i P a d ip a d 3G 4:08 PM Mail Weather Facebook WIRING PANELS VIA TABLETS OPTION 4: TABLETS CONTROLLER, STAR PANELS & COVE LIGHTING NEXT PANEL SHOOTING STAR COLOR CHANGING COVE (4 WIRES OR SINGLE COLOR COVE (2 WIRES) W/ STARY NIGHT EFFECTS FOR COVE LED ONLY RS-232 100-220V IPAD IPAD MINI IPHONE ANDROID NEXXUS DIN RAIL 12V/24V N L +V -V

WIRING PANELS VIA EP-TOUCH OPTION 5: EP-TOUCH, RS-232 CONTROLLER, STAR PANELS & COVE LIGHTING NEXT PANEL SHOOTING STAR COLOR CHANGING COVE (4 WIRES OR SINGLE COLOR COVE (2 WIRES) W/ STARY NIGHT EFFECTS FOR COVE LED ONLY RS-232 100-220V DIN RAIL 12V/24V N L +V -V

1 2 3 B STARS STARS E STARS D METEOR SHOWER METEOR SHOWER C SHOOTING STAR F G LOW VO LTAGE 2 CONDUCTOR CABLE (JUMPERS) 4 5 6 LOW VO LTAGE 2 CONDUCTOR CABLE (JUMPERS) I STARS EXAMPLE OF MULTI PANELS WIRING DIAGRAM LOW VO LTAGE 2 CONDUCTOR CABLE (JUMPERS) LOW VO LTAGE 2 CONDUCTOR CABLE (JUMPERS) A H STARS METEOR SHOWER STARS METEOR SHOWER EP-RS232 (FOR COVE) FOR STARS FOR COVE + - 150 WATTS 25 WA TTS + - FOR WIRING, PLEASE USE THE DAISY CHAIN SYSTEM WHEN CONNECTING PANEL TO PANEL LOW VOL TAGE 2 CONDUCTOR CABLE (JUMPERS) LOW VO LTAGE 2 CONDUCTOR CABLE (JUMPERS)