Underground Installation of Optical Fiber Cable by Pulling

Similar documents
Installation of Optical Fiber

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

FIBER OPTIC CABLE PULLING

Cable installation guidelines

Aerial Cable Installation Best Practices

Triax TechInfo. Installing and pulling Fibre Optic cables

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

A Comparison of Dry Versus Gel Filled Optical Cables

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Placing Fiber Optic Cable in Underground Plant

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

Selecting the correct cable type for Outside Plant Application

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

Underground Installation of Optic Fiber Cable Placing

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

Installing fiber optic cables

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Aerial Installation Guidelines for Fiber Optic Cable

Dry-Core ADSS Cable Placement

Micro duct Cable with HDPE Sheath for Installation by Blowing

Field Instruction. Any registered training organisation UETTDRCJ21A Lay ESI electrical cables. Before commencing work:

Micro Cables, Application (Ducts & Accessories, Equipments, Installation)

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

Water blocking tape. Locator ridge HPA-0486

STRUCTURED CABLE SYSTEM (SCS)

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

Public Works Division Lighting District Fiber Optic Specifications April 2009

Section Communications Optical Fiber Backbone Cabling

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Cable Installation Tips

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

Cable Installation Tips

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

High Voltage Cables kv. Handling and Operating Instructions

FusionLink Central Tube Ribbon Preparation & handling procedure

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved.

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

Laying of cables and lines in electrical installations and data networks

Gel-sealed in-line fiber optic closure

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

New Ultra-Density Fiber Cable Technology for FTTx and Access Markets Using New SpiderWeb Ribbon

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

Cold Shrink Straight Joint

OmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet

Microduct Fiber Optic Cable Installation procedure

HCS - HES Cabling Systems

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

SLiC Fiber Aerial Closure System

SECTION COMMUNICATIONS HORIZONTAL CABLING

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE AND COMPONENTS. July 19, 2013

TECHNICAL SPECIFICATION

SECTION COMMUNICATIONS HORIZONTAL CABLING

SPECIFICATION. Spec No : VSS-1402-CS603B

Microduct Fiber Optic Cable Installation Procedure

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

Michigan State University Construction Standards EXTERIOR FIBER OPTIC CABLE SYSTEM PAGE

Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)

TECHNICAL SPECIFICATION

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Fiber Optic Cable System

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

3M Fiber Optic Wall Mount Enclosure 8430 Series

FREEDM Loose Tube Interlocking Armored Cables

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

Mining and Petrochemical Fiber Optic Cables

Pocket guide to cable management

TN1205 Technical note

Color Codes of Optical Fiber and Color Shade Measurement Standards in Optical Fiber Cables

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

SECTION FIBER OPTIC STATION CABLES

SPECIAL SPECIFICATION 1438 Fiber Optic Cable (Single mode and Multimode)

WIRE CABLES PULL CABLES WR CONTROLS FLEXBALL ITALIANA CONDUIT FOR PULL CABLES WIRE FOR PULL CABLES

220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX

VITALink MC. 2 Hour Fire Rated Cable UL FHIT 120/ULC S139 FHIT Installation Manual

Mar11 Rev E

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

18mm ECAM Cable Entry Port

Transcription:

Application Notes Underground Installation of Optical Fiber Cable by Pulling Authors Prasanna Pardeshi and Sudipta Bhaumik Issued July 2015 Abstract This application note discusses underground fiber optic cable installation by pulling technique, the factors effecting pulling performance & best practices. Keywords Fiber optic cable, Underground installation, Cable pulling

Introduction Optical fiber cables for telecommunication application have been installed in pipes/ducts for many years. The installation process is influenced by local conditions, local climate, customer s existing procedures, and customer requirements. There are two basic methods of cable installation in a preinstalled duct Pulling method and Blowing method. The cable installation method is selected based on site conditions and availability of machinery & resources. Table 1 shows a comparison between the two installation methods. Table 1 Comparison between Pulling and Blowing methods Pulling Method Pulling rope pre-installed Equipment and manpower at two sides High sidewall forces on cables and ducts may lead to cable damage Mainly manual pulling is practiced. Machine pulling needs one hydraulic power pack Mainly used for straight duct route Suitable for short distance (few 100 meters) installation Blowing Method No pulling rope to install Equipment and manpower at one side Forces on cable and duct can be monitored and controlled and minimal chance of cable damage Large compressor and/or hydraulic power pack at one side Preferred for duct route with multiple bends and undulations Preferred for long distance (over 2 km) installation Pulling procedure is necessary and unavoidable in certain areas such as the small areas, small patches where blowing set up is not able to be accommodated. In this application note, cable installation by pulling method and its best practices are explained. Pulling Method Cable installation into a pre-installed underground ducts/pipes by manual pulling or by puller machine is called as Pulling Method. In this method, cable is pulled through duct/pipes with the help of pre-installed rope inside the duct/pipes. Optical fiber Cable pulling in underground horizontal duct routes requires some special considerations. These considerations are familiar to the installers who are specialize in optical fiber cabling installation, but may be unknown to the contractor who has dealt primarily with copper cabling. Failing to follow such a procedure can result in fiber/cable damages or high optical power losses after installation. Optical fiber cable pulling is generally preferred in access networks where underground ducts/ pipes are not continuous for more than 200 to 300 meters and cable needs to be stored in coil form at each manhole/handhole available at every 200 to 300 meters. If cables are pulled into conduit or inner duct, the Duct Fill Ratio to be maintained below 65%. The ratio between cross sectional area of the cable and inner space of the duct is known as Duct Fill Ratio (DFR) or Fill Ratio.

d DFR = 2 x100 D Where, 2 d= cable diameter D= duct inner diameter Cable Pulling Guidelines and Best Practices Duct Route Survey Conduct the duct route survey and inspect the route for manhole, coiling, splicing locations. Ensure there are no sharp bends or slops that exceed the minimum bend radius of the cable (refer cable supplier specification sheet). Identify and attain the potential problems during route survey. Identify the cable reel location/pulling location. Ensure the duct continuity is thorough and clear for the pulling length patch. Pulling Rope Ensure cable pulling rope is available in the duct. If pulling rope is not available inside the ducts then first install the pulling rope with the help of rodder as shown in Figure1. Push the rodder rod through one end of the duct/pipe and as the rodder rod reaches to other end of the duct/pipe, tie the pulling rope with the rodder rod at other end and reel back the rodder rod. Figure 1 Pulling rope installation by rodder Cable Pulling Grip Cable pulling grip shall be fixed at the head of the cable as shown in below figure 2. The function of this grip is to provide effective grip over cable sheath which is very useful during cable pulling. A wrap of plastic tape shall be wrapped around the grip which has been pulled tight over the cable. Figure 2 Wire mesh cable pulling grip

Breakaway Swivel It is strongly recommended to use breakaway swivel during manual pulling installation where pulling tension is not controlled. During manual pulling, applied pulling tension higher than the cable tensile rating can damage the cable and negatively impact its lifetime. Breakaway swivels are available with different tensile rating and can be placed in between cable and pulling rope. The main function of breakaway swivel is to break the swivel device if excess tension applied during cable pulling. For example, if cable rated tensile is 2700N and breakaway swivel having 2500N tensile strength is fixed, when the cable pulling tension goes above 2500N, the swivel will break so that excess pulling tension will not have any impact on cable. Pulling Rope Swivel Cable Pulling Grip Figure 3 Swivel Cable reel pay-off This feature is very important in optical fiber cable installation set-up to ensure cable is smoothly reel off. It is always recommended to use cable reel pay off during cable installation. The cable reel should be kept in level to avoid cable rubbing against the reel flanges. The cable reel orientation should be such that the natural payoff direction is towards the pulling direction. To eliminate possible cable contact with the ground, cable payout should be from the top of the reel. Figure 4 shows a cable reel in a cable reel pay-off and figure 5 shows the do s and don ts of cable unwinding. Figure 4 Figure 5 Figure 4 Cable reel pay-off Figure 5 Cable Handling All optical fiber cables are sensitive to damage during shipping, handling, and installation. Some of the important parameters that need special attention during cable pulling installation are: Cable bending radius: Optical fiber cables are designed with a minimum bending radius. The cable should never be bent below its minimum bending radius. Doing so can result in bending losses and/or fiber breaks in the cable. Generally the minimum bending radius of a fiber cable under load is 20 D, where D is the diameter of cable. Figure 6

Cable Pulling Tension: Optical fiber cables are designed with a maximum tensile strength. The cable should never be pulled beyond its maximum tensile strength. Exceeding the cable s pulling tension provided by Sterlite in the Cable Data Sheet / Specification, can alter cable and fiber performance and shorten its in-service lifetime. Cable Twist: Cable twist can develop stress on the fibers and therefore need to be avoided. Tension on the cable and pulling ropes can cause cable twisting. Use a swivel pulling eye to connect the pulling rope to the cable prevents pulling tension causing twisting forces on the cable as shown in figure 3. Unroll the cable off the reel loaded on pay-off or reel jack instead of manually taking out as shown in figure 4. When reel-off the cable for pulling, stored in figure-8 shape on the ground to prevent twisting. The figure 8 puts a half twist in one side of 8 and takes it out on the other side to prevent generation of twists in cable. Figure 7 Cable stored in fig-8 shape Cable Lubricants Use of cable lubricants to reduce co-efficient of friction between cable outer surface and duct inner surface is recommended to pull cable in a duct route having multiple bends, elevation and undulations. The lubricant material should not react with cable outer sheath (don t use soap water, kerosene, diesel). Apply right quantity of lubricant as suggested by the supplier. For additional information refer Sterlite application note titled Underground Installation of Optic Fiber Cable Placing (issue- November 2014). Copyright 2017 Sterlite Technologies Limited. All rights reserved. The word and design marks set forth herein are trademarks and/or registered trademarks of Sterlite Technologies and/or related affiliates and subsidiaries. All other trademarks listed herein are the property of their respective owners. www.sterlitetech.com