True RMS AC/DC Mini Clamp Meter

Similar documents
User s Manual. Model Digital Sound Level Meter

USER MANUAL. EMF Meter. Model EMF510. Additional User Manual Translations available at

CFM/CMM Thermo Anemometer

User Manual. Power and Harmonics Analyzer Model PQ3350

KHT 1000C HV-Probe Calibrator. Instruction Manual

DGC-1000A CLAMP-ON GROUND RESISTANCE TESTER

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

3.5 TFT LCD CCTV Service Viewer with Wristband

PRO-HDMI2DP HDMI 2.0a to DisplayPort 1.2a Converter. User s Guide. Made in Taiwan

Calibration Information

Cablesson HDelity 7.1ch Audio Extractor & Mixer. User Manual

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

INSTRUCTION MANUAL DAFM2

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

Model Number Structure

Clamp 200 A AC/DC (+ V AC/DC + Ω)

PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter. User s Guide. Made in Taiwan

PRO-CoaxExt HDMI extender over Coaxial cable with bi-directional IR User s Guide

BENESTON USER MANUAL AHD-ER03H. AHD to HDMI & VGA & AV Converter AHD-ER03H

MaxView Cinema Kit Quick Install Guide

BASIC PH METER BASIC PH METER KIT

HD-1x2-4K. Ultra Slim 6G HDCP 2.2 1x2 HDMI Splitter. Factor Electronics

Instructions. P MHz 1X/10X Passive Probe

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

SAFETY AND NOTICE TABLE OF CONTENTS

1X4 HDMI Splitter with 3D Support

DisplayPort Extender over 2 LC Fibers

OFI Optical Fiber Identifier User s Guide

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

ST-4000 SIGNAL LEVEL METER

Loctite. EQUIPMENT Operation Manual. Zeta 7011-A Dosimeter-Radiometer for UVA Part Number 98086

ST-4000D SIGNAL LEVEL METER

Mini HD-SDI Optical Transceiver Model No : VCF-MF01TXRX

Certificate of Calibration

32 Channel CPCI Board User Manual

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

CV-105. DVI & Audio to HDMI Converter. User Manual. Made in Taiwan

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Instruction Manual. 7" Wireless Camera System with Wired Side Camera Inputs RVS-355W. Reverse With Confidence 1

PRO-ScalerV2HD VGA to HDMI & Audio Scaler Converter. User s Guide. Made in Taiwan

CV-005B. Mini Component to HDMI Converter. User Manual. Made in Taiwan

STD-525T PRECISION TIMER

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

SP x6 12G/6G/3G/HD/SD-SDI Distribution Amplifier with Reclocking. User Manual. rev: Made in Taiwan

User Manual rev: Made in Taiwan

3G/HD/SD-SDI to HDMI Converter

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

PRODUCT MANUAL : 1x8 Splitter/Extender : Receiver (Sold Separately)

HOME THEATER. HDMI Selector Switches. Vanco Part Numbers (5x1) (3x1) Technical Support

Users Manual. Stroboscope. September 2014

3G/HD/SD-SDI to HDMI Converter with Audio Extraction and Mixer

HDMI Extender over UTP Cable

TR-2 OPERATION MANUAL

VideoSplitter HDMI 4K PT

Introduction Congratulations and thank you for purchasing W Box Technologies 0E-HDMISPL2.

VectorVGA Tempest User Manual

CVSB/ S-video/ HDMI to HDMI Scaler with 720p and 1080p Switching.

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

LIGHT COPILOT II. elationlighting.com Internet:

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

TVAC20000 User manual

WQ Series Water Quality Bench top Meters

DisplayPort Extender over 2 LC Fibers

HDMI Extender Transmission more than 3800M

Utility Amplifier GA6A Model

Indoor/Outdoor Security System with Quad Monitor User s Manual

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

SCALE & WEIGHT DISPLAYS

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

Dynatel Advanced Cable Locator 2250

User Guide. HDMI Active Cable Extender. DVI-7370c

User s Manual. 4X1 HDMI Switcher Part #: DL-HDS41

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

USER MANUAL Table of Contents

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

DA8-T DA8-T MANUAL

VGA to DVI Extender over Fiber SET

User Manual Power and Harmonics Analyzer Model PQ3350

900-Lumen Portable LED Projector Part #: User manual

80i-500s AC CURRENT PROBE FOR OSCILLOSCOPES

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

Metal Electrode Meter

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

User Manual TLS HDMI Switch 4/1 MHL

HDMI 1.3 Receiver over Signal. CAT5/CAT6 Cable. Model #: HDMI-C5-R-M. 1

Noise Detector ND-1 Operating Manual

1x6 3G/HD/SD-SDI Distribution Amplifier with Reclocking

SD/HD-SDI 1 to 2 Distribution Amplifier VCF-1002DA-P

Phone (440) Fax Wireless Rear Observation System With Night Vision Camera

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

HDMI Converter. Operating Instructions(P/N of this Instructions is INSYH0101)

4x1 HD Analog Audio Switcher

Transcription:

User's Guide True RMS AC/DC Mini Clamp Meter Model 380947

Introduction Congratulations on your purchase of the Extech 380947 True RMS Clamp Meter. This Clamp meter measures current up to 400A DC/AC and measures Frequency up to 100 khz. Careful use of this meter will provide years of reliable service. Safety 1. NEVER exceed the specified voltage/current maximum 2. USE EXTREME CAUTION when working with high voltages. 3. NEVER operate the meter unless the back cover and the battery/fuse door are in place and fastened securely. International Safety Symbols Meter Description 1. Conductor under test 2. Clamp Jaws 3. Jaw trigger Opens the meter jaws 4. ZERO / Relative button Zeroes the DCA reading 5. Function select switch 6. HOLD button to freeze displayed reading 7. MAX/MIN button Press to track and view highest and lowest readings 8. LCD Display with function indicators, units of measure, and bargraph 2

Display icons Low battery DC AC AUTO MAN ZERO HOLD MAX MIN A M k Hz Direct current Alternating current Minus sign Automatic range (frequency only) Manual range Zero function HOLD function Highest reading Lowest reading Current unit of measure Prefix MEGA (millions of units) Prefix KILO (thousands of units) Hertz (unit of measure for frequency) Bargraph display The 40 segment bargraph display shown below is a graphical interpretation of the measurement. It is displayed under the display digits on the LCD. The bars in the bargraph indicate a presence of an electronic signal. The more bars showing, the higher the signal. The digits below the graph help the user see how many bars are showing. If 40 segments are showing, the bars will reach the 40 mark, if 20 bars are showing the bars will reach the 20 mark. The bargraph is to be interpreted based on the range the meter is in while the measurement is being made. If the bargraph shows 40 segments lit, then the signal is at the highest end of the meter s present range. 3

Operation AC Current Measurements WARNING: To avoid electric shock, disconnect the test leads from the meter before making current measurements. 1. Set the Function switch to the 4, 40, 100, or 400A AC range. 2. Press the Trigger to open the clamp jaw. 3. Clamp onto a single conductor (fully enclosing it). Do not allow a gap between the two halves of the jaw. 4. Read the ACA value on the LCD. DC Current Measurements WARNING: To avoid electric shock, disconnect the test leads from the meter before making current measurements. 1. Set the Function switch to the 40 or 400A DC range. 2. Press the DCA zero key to null the meter display. 3. Press the Trigger to open the current sense Jaw. 4. Fully enclose a single conductor to be measured. Do not allow a gap between the two halves of the jaw. 5. Read the DCA value on the LCD. Frequency Measurements 1. Ensure that at least 0.1A AC is detectable before measuring Frequency. 2. Set the Function switch to the Hz position. 3. Press the Trigger to open the jaw and fully enclose one conductor. 4. Read the Frequency measurement on the LCD in Hz. MIN, MAX Function Press the MIN/MAX key to display ONLY the highest (MAX) and the lowest (MIN) readings. Press the MIN/MAX key once to view the minimum reading, press it again to view the maximum reading. Note that the displayed readings will only change when a measurement is taken higher than the previous MAX or lower than the previous MIN readings. The HOLD display icon (along with the MIN or MAX icon) will appear on the LCD in MIN/MAX mode. Pressing the MIN/MAX key a 3 rd time returns the meter to normal operation. Data Hold To freeze the displayed reading on the LCD, press the Data Hold key (the HOLD icon will appear on the display). To release the Data Hold function and return the meter to normal operation, press the Data Hold key again (the HOLD icon will switch off). Zero button for Relative Measurements 1. Press the ZERO key and the present measurement will zero. 2. All subsequent measurements are displayed with respect to the zeroed reading. For example, if a 20A reading is zeroed and a 30A reading is subsequently measured, the LCD will display 10A. 3. To return to normal operation, press and hold the ZERO key for 2 seconds. 4. Note that Relative mode is not available if the MIN/MAX mode is enabled. 4

Battery Replacement 1. When the low battery symbol appears on the LCD, the batteries must be replaced. 2. Turn the meter off and remove the rear battery compartment screw. 3. Lift off the battery compartment cover and replace the two 1.5V AA cells. 4. Replace the compartment cover and secure the screw. You, as the end user, are legally bound (EU Battery ordinance) to return all used batteries, disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Cleaning Use only a dry cloth to clean the plastic case. 5

Specifications General Specifications Display 3-3/4 Digit LCD with 40 segment bargraph Functions Current (ACA, DCA) and Frequency (Hz) Polarity - indicates negative polarity (positive polarity assumed) Current sensor Hall effect Overload Display indicates 1 or -1 DCA zero adjust One-touch zero key (also used as a Relative function) Display rate 2 readings/second (20 readings/second for bargraph) Battery Two 1.5V AA batteries Operating temperature 4 0 F to 122 0 F (-10 0 C to 50 0 C) Operating Humidity < 85% RH Power consumption 10mA DC approx. Weight 6.2 oz. (190g) including battery Dimensions 7.2 x 2.5 x 1.4 (183 x 63.6 x 35.6mm) (H x W x D) Jaw opening 0.9 (23mm) Standards IEC 1010 Category III 300V, Category II 600V Range Specifications DC Current Resolution Accuracy (of rdg + digits) Overload Protect 40A 10mA ±(1.0% + 2d) 400A DC 400A (0 to 150A) 100mA ±(1.0% + 2d) 400A DC 400A (150 to 200A) 100mA ±(2.2% + 2d) 400A DC 400A (200 to 400A) 100mA ±(4.0% + 2d) 400A DC AC Current Resolution 50/60Hz 40Hz - 1kHz Overload Protect 4A (0 to 500mA) 1mA ±(1.5% + 7d) ±(2.0% + 7d) 400A AC 4A (500mA to 4A) 1mA ±(1.5% + 3d) ±(2.0% + 4d) 400A AC 40A 10mA ±(1.5% + 3d) ±(2.0% + 4d) 400A AC 100A (0 to 100A) 100mA ±(1.5% + 3d) ±(2.0% + 4d) 500A AC 400A (100 to 200A) 100mA ±(2.2% + 3d) ±(2.5% + 4d) 500A AC 400A (200 to 400A) 100mA ±(4.0% + 3d) ±(5.0% + 4d) 500A AC Frequency (Hz) Resolution Accuracy Sensitivity Overload Protect 40Hz to 250Hz 0.01 to 0.1Hz ±(0.5% + 2d) 3.0A 500A AC 250Hz to 10kHz 0.1 to 1Hz ±(0.5% + 2d) 0.3A 500A AC 6

Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department for authorization. Visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support lines: U.S. 877-439-8324, Intl. 603-324-7800 Technical support: Option 3; E-mail: support@extech.com Repair & Returns: Option 4; E-mail: repair@extech.com Product specifications subject to change without notice Visit our website: www.extech.com Extech Instruments Corporation, 9 Townsend West, Nashua, NH 03063 ISO 9001 Certified since 1995 7