What's the difference between history and sequence. function?

Similar documents
What's the SPO technology?

Agilent Technologies N5454A Segmented Memory Acquisition for Agilent InfiniiVision Series Oscilloscopes

Keysight Technologies Using Oscilloscope Segmented Memory for Serial Bus Applications. Application Note

Keysight Technologies Segmented Memory Acquisition for InfiniiVision Series Oscilloscopes. Data Sheet

Digital Oscilloscope Waveform Generator DC Power Supply Digital Multimeter Spectrum Analyzer Handheld Oscilloscope Probes & Accessories

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

What to look for when choosing an oscilloscope

1. Abstract. Mixed Signal Oscilloscope Ideal For Debugging Embedded Systems DLM2000 Series

Agilent I 2 C Debugging

Keysight Technologies Oscilloscope Memory Architectures Why All Acquisition Memory is Not Created Equal. Application Note

Low-speed serial buses are used in wide variety of electronics products. Various low-speed buses exist in different

Realizing Waveform Characteristics up to a Digitizer s Full Bandwidth Increasing the effective sampling rate when measuring repetitive signals

Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes

~.Yr / 12. Offset range: ±2 V (2 mv/div to 200 mv/div), ±SO V (> 200 mv/div to 5 V/div) "digital storage oscilloscope" 13.

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope

Keysight Technologies Mixed Analog and Digital Signal Debug and Analysis Using a Mixed-Signal Oscilloscope

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Solutions to Embedded System Design Challenges Part II

PicoScope 6407 Digitizer

Agilent MSO and CEBus PL Communications Testing Application Note 1352

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

Mixed Analog and Digital Signal Debug and Analysis Using a Mixed-Signal Oscilloscope Wireless LAN Example Application

A New "Duration-Adapted TR" Waveform Capture Method Eliminates Severe Limitations

Debugging Digital Cameras: Detecting Redundant Pixels

Agilent PN Time-Capture Capabilities of the Agilent Series Vector Signal Analyzers Product Note

PicoScope 6407 Digitizer

VPO Technology 1 / 6 GOOD WILL INSTRUMENT CO., LTD.

The Measurement Tools and What They Do

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

Digital Storage Oscilloscopes 2550 Series

Real-Time Spectrogram (RTS tm )

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

Logic Analyzer Triggering Techniques to Capture Elusive Problems

Boosting Performance Oscilloscope Versatility, Scalability

Using FastFrame Segmented Memory

SDS1000DL+/CML+ Series Digital Oscilloscope. DataSheet

Expect to Make Waves.

Datasheet SHF A

SDS1000C Specifications

Agilent Technologies 54522A

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

ADS1000C, CAL / CML Series

Understanding. FFT Overlap Processing. A Tektronix Real-Time Spectrum Analyzer Primer

Time-Saving Features in Economy Oscilloscopes Streamline Test

1 scope channel. 2 scope channels* 200 MSa/s 4 MB memory/ch. 200 MSa/s 2 MB memory/ch. 200 MSa/s 2 MB memory/ch

WaveSurfer MXs. The Specs You Want The Features You Need 200 MHz to 1 GHz

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

In the development of electronic instruments or the analysis

Agilent 6000 Series Oscilloscope Demo Guide

User Manual SDS1000CML+/SDS1000DL+ Digital Oscilloscope UM0101A-E01A SIGLENT TECHNOLOGIES CO,.LTD

GDB-03 Demo Module USER MANUAL GW INSTEK PART NO. 82DB-03000M01 ISO-9001 CERTIFIED MANUFACTURER

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

SignalTap Analysis in the Quartus II Software Version 2.0

MultiView Zoom Simplifies Navigation of Long Records to Speed Debugging and Analysis

Logic Analysis Basics

Logic Analysis Basics

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display

Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details

HAMEG. Oscilloscopes. Innovation right from the start. Oscilloscopes

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR AUTOMATIC VIDEO CORRECTOR TEKTRONIX, MODEL 1440 (NSN )

User s Manual. TDO1000/TDO2000 Series Oscilloscopes

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams

!Ill ~ 168. Model490 Dual Input, Dual Trace Automatic Peak Power Meter

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

Advanced Troubleshooting with Oscilloscopes 9000 Scope Hands-on Labs

PAM4 Transmitter Analysis

Advanced Test Equipment Rentals ATEC (2832)

CPE 200L LABORATORY 3: SEQUENTIAL LOGIC CIRCUITS UNIVERSITY OF NEVADA, LAS VEGAS GOALS: BACKGROUND: SR FLIP-FLOP/LATCH

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

LATCHES & FLIP-FLOP. Chapter 7

Digital Circuits I and II Nov. 17, 1999

SDS1000CNL+ Series Digital Oscilloscope. DataSheet

R&S FPS-K18 Amplifier Measurements Specifications

Data Converters and DSPs Getting Closer to Sensors

Operating Instructions

X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination

Quick Reference Manual

(Refer Slide Time: 2:05)

Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes

Agilent Technologies Pulse Pattern and Data Generators Digital Stimulus Solutions

User Manual. GPS-1000B+ series. Digital Oscilloscope V 1.1

User Manual. Digital Oscilloscope V1.9

Serial Decode I2C TEN MINUTE TUTORIAL. December 21, 2011

MS-32. Oscilloscope Mixed Signal Option. Add 32 Digital Channels to a 4 Channel Oscilloscope

Agilent InfiniiVision 7000 Series Oscilloscopes

WAVESURFER XS SERIES. The Everyday Oscilloscope that s Easy to Use

Development of Simple-Matrix LCD Module for Motion Picture

COMP2611: Computer Organization Building Sequential Logics with Logisim

Keysight Technologies CAN/LIN Measurements (Option AMS) for InfiniiVision Series Oscilloscopes

Technology of high-speed storage for target signal based on ARM7 + double NAND memory

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

Development of an oscilloscope based TDP metric

Oscilloscopes, logic analyzers ScopeLogicDAQ

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

User Manual SDS1000DL/CNL/CML. Series Digital Oscilloscope V 1.2 SIGLENT TECHNOLOGIES CO,.LTD

ASYNCHRONOUS COUNTER CIRCUITS

CBF500 High resolution Streak camera

WaveSurfer 3000 Oscilloscopes 200 MHz 500 MHz

BIGGEST TOUCH. BEST VALUE.

Transcription:

What's the difference between history and sequence function? Current high-performance oscilloscope provides a high sampling rate and high bandwidth, but in some continuous measurement of multiple low duty ratio of pulse or have a long free time pulse sequence signal (Burst), such as laser pulse and the stability, low duty ratio radar pulse, or even embedded in the circuit the occasional narrow pulse signal, to capture and view the multiple continuous pulse, must increase the oscilloscope sampling time. According to the theorem the sampling rate the sampling time = the storage depth, to improve the sampling time with the storage depth in a certain number, we have to reduce the sampling rate. Another way is to upgrade the storage depth, but because of the high-speed storage in oscilloscope is very precious, It s a high cost way. SDS2000 series oscilloscopes Siglent recently launched have 28 Mpts deepest memory. Under the 2 GSa/S sampling rate, the oscilloscope can only capture 14 ms signal. It s not enough to view the continuous multiple free time signal. So upgrade the storage depth to solve the problem is not an economic and efficient way. To this end, Siglent provides an effective way to solve the similar problem: the Sequence (Sequence waveform).just as its name implies is the memory of the oscilloscope can be divided into a number of sequences, each sequence of waveform that is put in the current triggered waveform, trigger a save one. In Sequence mode, the waveform capture rate can reach 300000 times. Cooperate SDS2000 oscilloscope unique History (History waveform) function, can see every moment of waveform captured and the time interval between two times. By this technique, the oscilloscope

can maintain the high sampling rate, means it can t lost signal details information, at the same time, we can acquire the signal we interest in for a long time, and not leak any useful information. Sequence 1 Sequence 2 Sequence 3 Stored Waveform of SDS2000 Sequence Schematic Figure 1 the princ iple of Sequenc e 1. For a long time to acquire burst signal. The Burst signal is often used in radar and sonar signals. Long time acquiring Burst signal with the traditional sampling method is a big challenge, which has to compromise between the acquisition time and sampling rate. In many cases, even reduce the sampling rate can't satisfy the acquisition time required. By adopting Siglent SDS2000 segmented storage technology to divide memory into several sequences, can achieve the purpose of collection and storage Burst signal for a long time, and can analyze the stored Burst signal. As shown in figure 2, the period of Burst signal is 1 ms and duty width is about 5 us. Under 28 Mpts storage depth and 2GSa/S sampling rate, the acquisition time of SDS2000 is 14 ms, that is, a total of 14 Burst signals can be acquired, which can be verified in figure 2. It is not enough to analyze the Burst signal. If the storage depth drop to 2.8 M, the oscilloscope acquisition time reduces for shorter 1.4 ms, one Burst signals can be acquired at most.

Figure 1 Burst waveform's Zoom view of SDS2000 For the same Burst signals, if open the Sequence mode, SDS2000 can acquire Burst signal for a longer time. As shown in figure 3. SDS2000 series oscilloscope in 28 MPTS standard memory can support up to 80000 frame sequence. For example, when set the oscilloscope waveform sequence frames to 4067, as shown in figure 3 and 4, the oscilloscope can acquire 4067 segments Burst signal.

Figure 2 Sequence waveform in overlay display mode view Figure 3 Sequence in waterfall display mode view Open History function History furnish navigation and playback of the Sequence, by using the fast forward and fast rewind function, you can quickly find the time period wanted to know, and view the current sequence number (NO) and the sequence of Time

information (Time) which can be used to determine the Time interval between the Time and events. The figure shows the time interval of the Sequence is 1 ms. Figure 4 waveform playback view in History function 2. Acquire narrow pulse for a long time Same to Burst waveform, for continuous accidental narrow pulse signal, firstly adopts the range owed method make the signal triggered stability. Under the maximum 28M storage depth, to maintain the 2G sampling rate, can only acquire 28M/2G, namely 14 ms waveform. That is a total of 14 narrow pulse signal can be collected.

Figure 5 the narrow pulse's Zoom view of SDS2000 If you open the sequence function, SDS2000 can acquire more occasional narrow pulse signal. Open the History function we can playback and analysis the narrow pulse signal which we care about. Figure 6 the narrow pulse view in Sequence waveform

Figure 7 the narrow pulse's History playback view