Bulletin 700-FE, -FS, -M, -CF, CRF, -HA, -HC, -HK, -HL Relays and Timers Quick Selection Table

Similar documents
ALLEN BRADLEY TIMING RELAY

Your order must include: cat. no. of the miniature contactor specified with coil voltage code and, if required, cat. no. of any accessories

Bulletin 100-G IEC Contactors

Bulletin 190 Compact. Combination Starters

Bulletin 100-G IEC Contactors

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft Power Relays

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Pluggable interface relays CR-M Miniature relays

Bulletin 305 AC Starters

relays Electromechanical 2006 /2007

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

Definite Purpose Contactors

Contactors and Contactor Assemblies

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

02/11/2015

Solid-State Digital Timer

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Solution Selection Guide

Pluggable interface relays CR-M Miniature relays

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Minicontactorrelay,2NO/2NC,DCoperated

Bulletin 190 IEC Modular Starter System

Interface Relays and Optocouplers Product group picture

AS09..S 3-pole Contactors - Spring Terminals

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Type Contact form Model

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Series CT7N Bimetallic Overload Relays

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

A V 50Hz / V 60Hz

Timer and switching relays Timers. Function timer relay. Additional function relay. Timer and switching relay

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Electromechanical Relays

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

10 SERIES. Light dependent relays A

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Level Measurement silometer FMC 420, FMC 423

Datasheet - SRB301LC 24VAC/DC

A / At MAR1 24 V c / 24 C 240 V a B Relay 1 x 8 A changeover 0.1 s C 100 h

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Bulletin 150, 154 Softstarters Quick Selection Table

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

High performance circuit breakers

02/11/2015

llen-bradley 194R-HM4-NFPA3

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Kuhnke Technical Data. Contact Details

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Electronic Timer Control Day Astronomic Electronic Control

Magnetic and Hydraulic-Magnetic Circuit Breaker

90 Series - Sockets and accessories for 60 series relays

AC1036. Definite Purpose Contactors

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electromechanical Relays

Selection guide siemens.com/sirius-modular-system

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Multifunction Digital Timer

3-pole contactors for standard applications

Modular pulse operated latching relay 16 A

Bulletin 500 Top Wiring For Motor Loads

Coils for solenoid valves

Ordering details. Approval. Classification

Magnecraft Power Relays. Catalog

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Photoelectrics Through-beam Type PA18C.T..., DC

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

30 mm Push Buttons 9001 K and SK Selector Switches

Data Sheet Definite Purpose Contactors Ex9CK Series


30 mm Push Buttons 9001K and SK Selector Switches

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Transcription:

Quick Selection Table Bulletin No. 700-FE 700-FS Type DIN Rail Timer DIN Rail Timer Control Outputs: Time Limit Instantaneous Operation Modes: N.O. or SPDT Timed SPDT DPDT, 2 N.O. + common ON-Delay, OFF-Delay, One Shot, Repeat Cycle-Pulse, Fleeting OFF-Delay, Pulse Converter, Star Delta Different Timing Modes Time Range 0.05 s 0 h 0.05s 60 h Supply Voltage 24V AC/DC, 0 240V AC 24V 48V AC/DC 24V 240V AC 2V DC 24V 48V DC 24V 240V AC Contact Rating at 20V AC 6 A 8 A Certifications cur, UL, CE cur, UL, CE Page Number 05 06 Bulletin No. 700-M 700-CF/700-CRF Type Miniature Control Relay Control Relay Spring Clamp Terminals Available as: 4 N.O.; 3 N.O., N.C.; Available as: 4 N.O.; 3 N.O., N.C.; Contacts 2 N.O., 2 N.C. 2 N.O., 2 N.C.; 4 N.C. Optional front-mounted 2 or 4 pole Optional front or side mounted, 2 or 4 external auxiliary contact block pole external auxiliary contacts blocks Dimensions (W x H x D) AC = 45 x 56 x 48 mm AC = 45 x 8 x 9.5 mm DC = 45 x 56 x 48 mm DC = 45 x 8 x 45.5 mm AC- Ratings 6A @ 500V (Standard) 20A @ 690V (Standard) 0A @ 500V (Bifurcated) 0A @ 690V (Bifurcated) AC-5 Ratings Coil Voltages Optional Accessories 2...20V AC, 0A 220 240V AC, 6A 360 400V AC, 2.5A 480 500V AC,.25A AC = 24-480V AC, 50-60Hz DC = 2-250V DC Front-mount auxiliary contacts, surge suppressors, electronic timers 2...240V AC, 0A 400V AC, 6A 480 500V AC, 2.5A 600...690V AC, A AC = 2-600V AC, 50-60Hz DC = 9-250V DC Front or side-mount auxiliary contacts, surge suppressors, electronic or pneumatic timers, mechanical latches Standards/Approvals UL, CSA, IEC, CE UL, CSA, IEC, CE Socket Type DIN Rail or Panel Mount DIN Rail or Panel Mount Page Number Page 09 Page 09 Rockwell Automation 03

Quick Selection Table Type Bulletin No. 700-HA 700-HC 700-HK 700-HL General Purpose Relay Interposing/Isolation Relay Interposing/Isolation Relay Interposing/Isolation Relay Contact Form DPDT, 3PDT 2PDT, 4PDT SPDT, DPDT SPDT ( c/o) N.O. (SSR) Contact Type Single, Bifurcated Single, Bifurcated Single Single Contact Material AgNi, AgNi + Gold AgNi, AgNi + Gold AgCdO, AgCd+Gold AgSnO Max. operating current under resistive load Min. permissible load Coil Voltage Permissible Coil Voltage Variation Dielectric Withstand Voltage Electric Service Life (cycles) Approvals Socket Type 0 A 700-HA: 0V, 50 ma 700-HAB: 6V, 30 ma 700-HAX: 6V, ma AC: 6V, 2V, 24V, 48V, 0V, 20V, 208V, 230V, 240V, 277V DC: 6V, 2V, 24V, 36V, 48V, 60V, 80V, 0V, 25V, 40V, 220V 80 0% of Nominal Voltage at 50 Hz 80 0% of Nominal Voltage at 60 Hz 80 0% of Nominal Voltage at DC Pole-to-pole: 2000V Contact-to-coil: 2000V Contact-to-frame: 2000V 0 A (2PDT) 7 A (4PDT) 0V ma (Gold), 0V 0 ma (Silver) AC: 6V, 2V, 24V, 20V, 240V DC: 6V, 2V, 24V, 48V, 0V 80 0% of Nominal Voltage at 50 Hz 80 0% of Nominal Voltage at 60 Hz 80 0% of Nominal Voltage at DC Pole-to-pole: 600V Contact-to-coil: 600V Contact-to-frame: 600V 5 A (DPDT), 0 A (SPDT) 6 A (SPDT), 2 A (SSR) 0V 50 ma (Silver), 5V 0 ma (Gold) AC: 6V, 2V, 24V, 20V, 240V DC: 6V, 2V, 24V, 48V, 0V 85 0% of Nominal Voltage at 50 Hz 85 0% of Nominal Voltage at 60 Hz 80 0% of Nominal Voltage at DC Pole-to-pole: 500V AC Contact-to-coil: 500V AC Contact-to-frame: 500V AC 2V 6 ma (72 mw) Silver 8V, 2.5 ma (20 mw) Gold AC: 2V, 24V, 48V, 0V, 20V, 230V, 240V DC: 2V, 24V, 48V, 25V, 230V, 240V 85 0% of Nominal Voltage at 50 Hz 85 0% of Nominal Voltage at 60 Hz 80 50% of Nominal Voltage at DC Pole-to-pole: Contact-to-coil: 4000V AC Contact-to-frame: 500V AC 00 000 minimum 00 000 minimum 00 000 minimum 00 000 minimum CE, culus, curus, ABS, IMQ, RINA 700-HN00, 700- HN0, 700-HN25, 700-HN26, 700- HN202, 700-HN203 CE, culus, curus, IMQ, ABS, RINA 700-HN03, 700-HN28, 700-HN04 CE, UL, UR, CSA 700-HN2 700-HN22 CE, curus, culus, ABS, IMQ Page Number Page 2 Page 3 Page 3 Page 4 04 Rockwell Automation

Product Selection: 700-FE Single Function Timing Relay Multi-function Timing Relay Star-Delta Timing Relay 700-FEAS 700-FEM3T 700-FEY2Q Description Single Function Timing Relay Width 7.5 mm according DIN 43880 Supply Voltage U22 Multi-time setting ranges 0.75 s h (5s) 0.75 5 s (m) 0.05 min (8m) 0.4 8 min (h) 0.05 h 24V AC/DC (A3/A2) 0 240V 50/60 Hz (A/A2) U23 Multi-time setting ranges 0.05 s 0 h (s) 0.05 s (0s) 0.5 0 s (m) 0.05 min (0m) 0.5 0 min (h) 0.05 h (0h) 0.5 0 h 24 48V DC (A/A2) 24 240V 50/60 Hz (A/A2) Functions Cat. No. PQ Cat. No. PQ (A) On-delay 700-FEASU22 700-FEA3TU23 (B) Off-delay 700-FEBSU22 700-FEB3TU23 (D) One shot 700-FEDSU22 700-FED3TU23 (F) Symmetric flasher starting with pulse 700-FEFSU22 700-FEF3TU23 (E) Fleeting off-delay 700-FEE3TU23 (L) Pulse converter 700-FEL3TU23 Multi-Function Timing Relay Width 7.5 mm according DIN 43880 Timing Relay includes 4 selectable Multi-time setting ranges 0.5 s h Multi-time setting ranges 0.05 s 0 h functions: (s) 0.05 s (A) On-delay (0s) 0.5 0 s (0s) 0.5 0 s (B) Off-delay (m) 0.05 min m) 0.05 min (D) One-shot (0m) 0.5 0 min (0m) 0.5 0 min (F) Flashing started by impulse (h).05 h (h) 0.05 h (0h) 0.5 0 h Supply Voltage Cat. No. PQ Cat. No. PQ U22 0 240V, 50/60 Hz (A/A2) 700-FEMRU22 24V AC/DC (A3/A2) U23 24 48V AC (A/A2) 700-FEM3TU23 24 240V, 50/60 Hz (A/A2) Star-Delta Timing Relay Width 7.5 mm according DIN 43880 Multi-time setting ranges 0.5 s 0 h (3s) 0.5 3 s (0s) 0.5 0 s (m) 0.05 min (0m) 0.5 0 min Function Cat. No. PQ (Y) Star-delta timing relay 700-FEY2QU23 Rockwell Automation 05

Product Selection: 700-FS 700-FSM Multi-Function Timing Relays Width 22.5 mm according to DIN 43880 700-FSH Description The multi-function timing relay 700-FSM includes 0 functions selectable: Multi-time setting range 0.05 s 60 h (A) On-delay (s) 0.05 s (B) Off-delay (3s) 0.5 3 s (C) On- and off-delay (0s) 0.5 0 s (D) One shot (mn) 0.05 min (E) Fleeting off-delay (3mn) 0.5 3 min (F) Symmetric flasher starting with pulse (0mn) 0.5 0 min (I) On-delay pulse generator (h) 0.05 h (L) Impulse converter (3h) 0.5 3 h (On) ON-function (for installation and maintenance) (0h) 0.5 0 h (Off) OFF-function (for installation and maintenance) (60h) 3 60 h Available Supply Voltage (A/A2) Cat. No. PQ Cat. No. PQ from stock U23 24 48V DC 24 240V 50/60 Hz 700-FSM3UU23 700-FSM4UU23 on request Z2 2V DC 700-FSM3UZ2 700-FSM4UZ2 on request U8 24 240V AC/DC 700-FSM3UU8 700-FSM4UU8 on request A40 400V 50/60 Hz 700-FSM3UA40 700-FSM4UA40 Timing relay with special function Width 22.5 mm according to DIN 43880 Supply Voltage (A/A2) Z2 2V DC U23 24 48V DC, 24 240V 50/60 Hz A40 400V 50/60 Hz (H) Flasher (repeat cycle starting with pulse or pause) Function Cat. No. PQ Multi-time setting range U 0.m60 h (s) 0.05 s (0m) 0.5 0min (3s) 0.5 3s (h) 0.05 h (0s) 0.5 0s (3h) 0.5 3h (m) 0.05 min (0h) 0.5 0h (3m) 0.5 3min (60h) 3 60h 700-FSH3UU23 700-FSH3VU23 700-FSH3UZ2 700-FSH3VZ2 700-FSH3UA40 700-FSH3VA40 from stock from stock Multi-time setting range 0.5 s 0 min (2.5s) 0.5 2.5 s (80s) 4 80 Supply Voltage (A/A2) s U8 24 240V AC/DC (0s) 0.5 0 s (0m) 0.5 0 min Function Cat. No. PQ Cat. No. PQ (Q) Off-delay without supply voltage 700-FSQ3QU8 700-FSQ4QU8 06 Rockwell Automation

Product Selection: 700-FS 700-FSA 700-FSY2 Single-Function Timing Relays Width 22.5 mm according to DIN 43880 Description! Available mono-time ranges Complete the Cat. No. with the corresponding identification! from the table on the next page. Supply Voltage (A/A2) Z2 2 VDC U23 24 48 VDC 24 240 V 50/60 Hz U8 24 240 VAC/DC A40 400 V 50/60 Hz (A) On-delay (B) Off-delay (C) On- and off-delay (D) One shot! Mono-Time Ranges, see Page 08 Multi-time setting ranges 0.05 s 60 h (s) 0.05 s (m) 0.05 min (h) 0.05 h (3s) 0.5 3 s (3m) 0.5 3 min (3h) 0.5 3 h (0s) 0.5 0 s (0m) 0.5 0 min (0h) 0.5 0 h (60h) 3 60 h Function Cat. No. PQ Cat. No. PQ 700-FSA3!U23 700-FSA3UU23 700-FSA3!Z2 700-FSA3UZ2 700-FSA3!U8 700-FSA3!A40 700-FSA3UA40 700-FSB3!U23 700-FSB3UU23 700-FSB3!Z2 700-FSB3UZ2 700-FSB3!U8 700-FSB3!A40 700-FSB3UA40 700-FSC3!U23 700-FSC3!Z2 700-FSC3!U8 700-FSC3!A40 700-FSD3!U23 700-FSD3!Z2 700-FSD3!U8 700-FSD3!A40 700-FSA4UU23 700-FSA4UZ2 700-FSA4UA40 700-FSB4UU23 700-FSB4UZ2 700-FSB4UA40 - - Rockwell Automation 07

Product Selection: 700-FS Single-Function Timing Relays Width 22.5 mm according to DIN 43880! Mono-Time Ranges Complete the Cat. No. with the mono-time range identification Time Ranges 0.05 s 0.5 3 s 0.5 0 s.5 30 s 0.05 min 0.5 3 min! A B C D E F Time Ranges 0.5 0 min.5 30 min 0.05 h 0.5 3 h 0.5 0 h 3.0 60 h! G H I J K L Special Single-Function Timing Relays Width 22.5 mm according to DIN 43880 Supply Voltage (A/A2) U23 24 48VDC 24 240V 50/60 Hz A40 400 V 50/60 Hz (Y) Star-delta timing relay (Y) Star-delta timing relay! Available mono-time ranges Complete the Cat. No. with the corresponding identification! from the table below. Function Cat. No. PQ 700-FSY2!U23 700-FSY2!A40! Mono-Time Ranges Complete the Cat. No. with the mono-time range identification Time Ranges 0.5 0 s.5 30 s 0.05 min 0.5 3 min 0.5 0 min! C D E F G 08 Rockwell Automation

Control Relays Bulletin 700-FE, -FS, -M, -CF, CRF, -HA, -HC, -HK, -HL Product Selection: 700-M, 700-CF, 700-CRF AC-control AC- AC-5 I e [A] I e [A] Contacts 40 C 240V 400V N.O. N.C. DC-control 6-2.5 25 0 5 AC- AC-5 I e [A] I e [A] Contacts 40 C 240V 400V N.O. N.C. 6-2.5 25 0 5 DC version with diode protection circuit with surcharge. Standard Control Voltages, see Page 0 Screw Terminals Spring Clamp Terminals Cat. No. PQ Cat. No. PQ 2 2 700-M220 3 700-M30 4 0 700-M400 +L +L 700-MZ220 2 2 700-CF220 700-CRF220 3 700-CF30 700-CRF30 4 0 700-CF400 700-CRF400 Screw Terminals Spring Clamp Terminals Cat. No. PQ Cat. No. PQ 2 2 700DC-M220 3 700DC-M30 4 0 700DC-M400 +L +L 700DC-MZ220 2 2 700-CF220 700-CRF220 3 700-CF30 700-CRF30 4 0 700-CF400 700-CRF400 Options Cat. No. Suffix Description Ordering Example Control Voltage AC e.g. A Voltage Selection Code from table 700-M220A Package Quantity 700-M Package Quantity 700-C 700-M 700-CF 700-CRF No entry Multi-pack (0 pieces) only A24, A, KF, A3A 700-M220 S Single item ( piece, standard) 700-M220 3S No entry Single item ( piece, standard) 700-CF220 M Multi-pack (20 pieces) 700-CF220 M! Attention: Bulletin 700-M S: Standard quantity = Single item piece Bulletin 700-C: Standard quantity= Single item piece, see Page 0 Rockwell Automation 09

Product Selection: 700-M, 700-CF, 700-CRF Control Relays Standard Control Voltages for AC-control Available control voltages: 2...500V 50 Hz / 2...600V 60 Hz 700-M 700-CF 700-CRF [Hz] [V] [V] 24 48 0 0-20 220-230 230 380-400 400-45 50 Hz - - A - (A2) - A3 60 Hz - - - A - - - A3 50/60 Hz A24 A48 - - - KF - - 2 24 32 36 42 48 00 00-0 0 20 27 200 50 (R) (K) (V) (W) (X) (Y) (KP) - (D) (P) (S) (KG) - - - CF) - 60 (Q) (J) - (V) - (X) - (KP) - (D) - - (KG) - (L) - - 50/60 - KJ - - - KY (KP) - KD - - (KG) - (KL) - - KF [Hz] [V] 230-240 240 277 347 380 380-400 400 400-45 200-220 440 480 500 550 600 50 (VA) (T) - - - (N) - (G) (B) - (M) (C) - 60 - (A) (T) (I) (E) - - - (N) (B) - - (C) 50/60 - (KA) - - - - KN - (KB) - - - - 200-230 208-240 220-230 230 Standard Control Voltages for DC-control Available control voltages: 2...250V DC 700DC-M..Z [V] 24 48 0 220 CC Z24 (Z48) Z (Z2) with diode protection circuit CC D24 - - 700-CF [V] 9 ➊ 2 24 ➋ 36 48 60 64 72 80 0 5 25 220 230 250 700-CRF DC (ZR) (ZQ) ZJ (ZW) (ZY) (ZZ) (ZB) (ZG) (ZE) ZD (ZP) (ZS) (ZA) (ZF) (ZT) with diode protection circuit DC DJ DC version with diode protection circuit with surcharge ( ) Control voltages in parentheses: No stock item ➊ Extended operating limits 0.65.3 x U s ➋ Extended operating limits 0.7.25 x U s 0 Rockwell Automation

Auxiliary Contact Blocks for Front Mounting Bulletin 700-FE, -FS, -M, -CF, CRF, -HA, -HC, -HK, -HL Accessories: 700-M, 700-CF, 700-CRF 95-MA 00-FA 00-CRFA Description N.O. N.C. For type Auxiliary Contact Blocks 2 and 4 pole Quick and easy mounting without tools Electronic compatible H-contacts Mutual positive guidance to the main contactor poles Models with equal function with several terminal numbering choices Auxiliary Contact Blocks for Front Mounting ➊ 2 and 4 pole Quick and easy mounting without tools Electronic compatible contacts Mutual positive guidance to the main contactor poles (except for L-types) Models with equal function with several terminal numbering choices L = Late break / Early make Other accessories for 700-M and 700-CF see Pages 30 38 Screw Terminals Spring Clamp Terminals Cat. No. PQ Cat. No. PQ 0 2 700-M400 95-MA02 700-M400 95-MA 700-M400, 2 0 -M30, -M220, 95-MA20 -MZ220 0 4 700-M400 95-MA04 2 2 700-M400 95-MA22 4 0 700-M400, -M30, -M220, -MZ220 95-MA40 0 2 700-CF, -CRF 00-FA02 00-CRFA02 700-CF,-CRF 00-FA 00-CRFA 2 0 700-CF,-CRF 00-FA20 00-CRFA20 2 2 700-CF,-CRF 00-FA22 00-CRFA22 3 700-CF,-CRF 00-FA3 00-CRFA3 4 0 700-CF,-CRF 00-FA40 00-CRFA40 + L ➊ Control relay and auxiliary contact block AC / DC max. 4 N.C. + L 700-CF,-CRF 00-FAL22 00-CRFAL22 Options Cat. No. Suffix Description Ordering Example Package Quantity No entry Single item ( piece, standard) 00-FA M Multi-pack (0 pieces) 00-FAM Rockwell Automation

Product Selection: 700-HA Plug-in Relays with 2 or 3 Changeover Contacts 700-HA32 Push-to-test, manual override 8-pin 2 changeover contacts Push-to-test, manual override and LED 8-pin 2 changeover contacts 700-HA33 Push-to-test, manual override -pin 3 changeover contacts Push-to-test, manual override and LED -pin 3 changeover contacts Base Socket Plug-in Relay 700-HA Multi-function Timer Module Base Socket 700-HN Description [V] Cat. No. PQ 2V 50/60Hz 700-HA32A2-3 24V 50/60Hz 700-HA32A24-3 48V 50/60Hz 700-HA32A48-3 20V 50/60Hz 240V 50/60Hz 700-HA32A-3 700-HA32A2-3 2V DC 48V DC 0V DC 700-HA32Z2-3 700-HA32Z24-3 700-HA32Z48-3 700-HA32Z-3 24V 50/60Hz 700-HA32A24-3-4 20V 50/60Hz 700-HA32A-3-4 240V 50/60Hz 700-HA32A2-3-4 700-HA32Z24-3-4 2V 50/60Hz 700-HA33A2-3 24V 50/60Hz 700-HA33A24-3 48V 50/60Hz 700-HA33A48-3 20V 50/60Hz 700-HA33A-3 240V 50/60Hz 700-HA33A2-3 2V DC 700-HA33Z2-3 700-HA33Z24-3 48V DC 700-HA33Z48-3 0V DC 700-HA33Z-3 24V 50/60Hz 700-HA33A24-3-4 20V 50/60Hz 700-HA33A-3-4 240V 50/60Hz 700-HA33A2-3-4 700-HA33Z24-3-4 Special versions with double or gold contacts on request. Available control voltages 6 240V 50/60 Hz. 6 220V DC Time Module 700-HT Description For Relays Cat. No. PQ 8-pin (use with or without optional timer module) 700-HA32 700-HN202 -pin (use with or without optional timer module) 700-HA33 700-HN203 0 8-pin 700-HA32 700-HN00 -pin 700-HA33 700-HN0 Description Control Voltage Cat. No. PQ Choice of 8 functions 24 240V AC/DC 700-HT Choice of 8 time ranges 0. 240 h Use with sockets 700-HN202 or 700-HN203 2 30V DC 700-HT2 2 Rockwell Automation

Product Selection: 700-HC, 700-HK Slim Line Relays Type HK with Plug-in Quick Connect Terminations ➊ Relay 700-HK Description Contact Rating Pilot light option: Add suffix (-4) to be selected HC relay Cat. No. Miniature Square Base Relays Type HC with Blade Terminals Wiring Diagrams Control Voltage ➊ Push-to-test option: Add suffix (-3) to the selected HC relay Cat. No. ➋ LED option: Add suffix (-4) to the selected HC relay Cat. No. except for the 240V AC, units add (-4L). ➌ Push-to-test and LED option: Add suffix (-3-4) to the selected HC relay Cat. No. Cat. No. ➊ 24V AC 700-HKX6A24 changeover contact 4 0 A Contacts: bifurcated gold overlay, AgCdO 20V AC 700-HKX6A 700-HKX6Z24 24V AC 700-HK36A24 2 20V AC 700-HK36A changeover contact 0 A 240V AC 700-HK36A2 A2 Contacts: AgCdO A 700-HK36Z24 _ U + 0V DC 700-HK36Z Socket Base 700-HN2 0 24V AC 700-HKX2A24 2 changeover contacts 4 24 5 A Contacts: bifurcated gold overlay, AgCdO 20V AC 700-HKX2A 2 700-HKX2Z24 24V AC 700-HK32A24 2 22 20V AC 700-HK32A 2 changeover contacts 5 A 240V AC 700-HK32A2 Contacts: AgCdO A2 A 700-HK32Z24 _ U + 0V DC 700-HK32Z Socket Base 700-HN22 0 Description Contact Rating Relay 700-HK Wiring Diagrams Control Voltage Relay 700-HC Cat. No. ➊ ➋ ➌ 4 changeover contacts 24V AC 700-HC4Z24 Form C AgNiAu gold plated 7 A 2 22 32 42 24V AC 700-HC4A24 contacts 4 24 34 44 20V DC 700-HC4A 24V AC 700-HC24A24 2 3 4 20V AC 700-HC24A 7 A 4 changeover contacts A A2 (C300) 240V AC 700-HC24A2 Form C contacts AgNi (R300) 700-HC24Z24 U + 0V DC 700-HC24Z Socket Base 700-HN04 0 PQ PQ Rockwell Automation 3

Product Selection: 700-HL Terminal Block Relays Bulletin 700-HL Up to 85% panel space savings vs. traditional relays DIN rail mounting Only 6.2 mm wide (SPDT) Standard LED, Reverse Polarity Protection and Surge Protection 700-HLT 700-HLS Silver Plated Contacts Silver Plated Contacts Spring Clamp Version Gold Plated Contacts Gold Plated Contacts Spring Clamp Version Description Silver Plated Contacts; Built-in Leakage Current Suppression Circuit Gold Plated Contacts; Built-in Leakage Current Suppression Circuit Solid State Solid State Spring Clamp Version Solid State; Built-in Leakage Current Suppression Circuit Input Voltage Contact Rating No. of Cat. No Contacts 700-HLTZ24 24V AC/DC 700-HLTU24 6 A c/o 0/25V AC/DC 700-HLTU 220 240V AC/DC 700-HLTU2 700-HLT2Z24 24V AC/DC 700-HLT2U24 6 A c/o 0/25V AC/DC 700-HLT2U 220 240V AC/DC 700-HLT2U2 700-HLTZ24X 24V AC/DC 700-HLTU24X 6 A c/o 0/25V AC/DC 700-HLTUX 220 240V AC/DC 700-HLTU2X 700-HLT2Z24X 24V AC/DC 700-HLT2U24X 6 A c/o 0/25V AC/DC 700-HLT2UX 220 240V AC/DC 700-HLT2U2X 240V AC 700-HLTL2 6 A c/o 20/25V AC/DC 700-HLTL 240V AC 700-HLTL2X 6 A c/o 20/25V AC/DC 700-HLTLX 700-HLSZ24 0/25V AC/DC 2 A N.O. 700-HLSU 220 240V AC/DC 700-HLSU2 700-HLS2Z24 0/25V AC/DC 2 A N.O. 700-HLS2U 220 240V AC/DC 700-HLS2U2 240V AC 700-HLSL2 20/25V AC/DC 2 A N.O. 700-HLSL ➊ Reverse polarity on the output terminals of the solid-state relay will result in the output being «ON» regardless of the state of the input voltage. ➋ Electromechanical relay to solid-state relay interchangeability possible. ➋ ➋ ➋ ➋ PQ 0 0 0 0 ➋ 0 ➋ 0 ➊ ➋ 0 ➊ ➋ 0 ➊ ➋ 0 4 Rockwell Automation

Accessories Bulletin 700-FE, -FS, -M, -CF, CRF, -HA, -HC, -HK, -HL Product Selection: 700-HL 700-TBR.. 700-TBS.. 700-HN77 Replacement Relays Description Socket Input Voltage Cat. No PQ Replacement Solid-State Relays 4-blade miniature relay for use with N. O. SSR output. 24V 220 240V, 20 25V 24V 220 240V, 20 25V 700-TBR24 700-TBR60 700-TBS24 700-TBS60 20 20 20-Way Jumpers Can be cut to required length. I th = 36 A max. per 20-way jumper. Description Colour Cat. No PQ End Barrier Used for visual separation of groups, safe separations of neighboring 700-HL modules that end with jumpers. Red Gray Blue 700-TBJ20R 700-TBJ20G 700-TBJ20B Black 700-HN77 Rockwell Automation 5