MÜNCHNER KAMMERSPIELE

Similar documents
Theatre Technical Specifications

Louis Koo Cinema Venue Specifications (updated 2018)

RPAC REDLANDS PERFORMING ARTS CENTRE

Technical Specification (Studio Theatre)

Technical Specifications

Mics, DIs, Stands, and Cables

SHIRO TAKATANI CHROMA Technical Requirement Sound

TECHNICAL REQUIREMENTS

Technical Specification (Studio Theatre)

Technical Specifications. Taylor Little Theater

Project manager (PM): Pamela Næss Mail: Phone:

Technical Specification

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Project manager (PM): Pamela Næss Mail: Phone:

Meeting Room Overview/Descriptions

EDITION CONFERENCE, SEMINAR & CORPORATE EVENT AUDIO-VISUAL HIRE SPECIALISTS

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Extraordinary Meeting Experience PROFESSIONALISM - FLEXIBILITY - HIGH TECNOLOGY

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Monty Kultuurfaktorij Technical Rider

There are 10 dressing rooms in Theatre Kerkrade.

CHELSEA THEATRE. Technical Specifications

Dinkelspiel Auditorium - Technical Specifications

THE REPUBLIC CULTURAL CENTRE TECHNICAL FACILITIES (STUDIO)

Dr JOHN GALLAGHER CONCERT CHAMBER

TECHNICAL SPECIFICATIONS

Matt Dann Cultural Centre

PACKAGES FOR A/V EQUIPMENT including savings for the Kap Europa

413 LANCASTER STREET WEST KITCHENER, ONTARIO N2H 4V8 PHONE : (519)

The Haymarket Basingstoke Technical Specifications

ICM Internationales Congress Center München DETAILS ROOM 14 including technical specifi cations and seating variants

Main House Technical Specifications

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

Technical Data Sheet

Audiovisual Hire Price List September Code Audiovisual Image Day Rate OVERHEAD Overhead projector $35.00

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

isync HD & isync Pro Quick Reference Guide isync HD isync Pro Digital Video Processor and Video/Audio Switcher

In this issue... NEW! MS input HD PPU Shipping! MCU remote camera controller User story

Video Series. HCS-4311M Professional Mixed Matrix for Conference 8.2. HCS-3313C High Quality Speed Dome Camera (ceiling) 8.5

Blue Bridge Repertory Theatre Technical Specifications

2017 TECHNICAL SPECIFICATIONS

Arcadia Performing Arts Center Technical Specifications and Information

Technical Specification (Drama Theatre)

There are 2 dressing rooms dedicated to the RABOzaal. Each room has at least 1 hand basin.

AUDIO SPEAKERS / AMPLIFICATION

Section A: Front of House (FOH) Public Address (PA) Speaker System

TECHNICAL SPECIFICATION

Everyness. Wang Ramirez Company TECHNICAL RIDER

TECHNICAL RIDER KOMEDIE

Main Stage Technical Specs - Hall #2

Technical Specification (Drama Theatre)

UTAH 100/UDS Universal Distribution System

Technical Specifications

1.4 Conduit Position Clearance from Wall mm minimum mm+ prefer

SHIVER. Technical rider update : 10th feb Premiere at Theater l Arsenic in Lausanne/Suisse the 4th of february 2014

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

THE STREET THEATRE. Technical Specifications

T1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422

Technical specifications Main theatre. Sound

Camden Opera House Theater. Technical Information

Aalborg Universitet. The Usability Laboratory at Cassiopeia Kjeldskov, Jesper; Skov, Mikael; Stage, Jan. Publication date: 2008

Technical Rider. STAGE 32 m wide x 13 m deep (from the prompt)

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

Theatre Technical Specifications

Technical Specifications

"The Road Is Just A Surface" by Anja Garbarek and Jo Strømgren Kompani Technical Requirements

Technical Rider. Space A. February 2018

Technical Specifications (Concert Hall)

AUDIO VISUAL SOLUTIONS. price guide

photo by courtesy of Christiaan Beukes - Sphere Custom Design, RSA FORCE SERIES XXL HOME THEATRES VIDEO-PROJECTORS FOR

Technical Specification Pavilion Dance

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Acacia Site Map. Site Facilities

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

350 fixed seats with the capabilities of an additional 50 removable seats.

Smart Digital Solutions MDX-8x8

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

ON-AiR / PRODUCTiON DiGiTAl MixiNG CONSOle. A lot more broadcasting for a lot less money

Video & Audio Transmission

Technical Specifications Nov 2016

National Theater_sound

Resource Sharing with Studer consoles

Sound Equipment Sound Control Room

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

SCHEDULE F EQUIPMENT AND SPECIFICATIONS -- GURAL THEATRE

Technical Information

JONES GRADUATE SCHOOL. Classrooms 116, 212, 214, 218, 312, 314 and 318. Users Guide


CENTRE FOR PERFORMING ARTS

Audio-Visual Systems Description

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point)

Hire List As of 12 th March 2018

Technical Informa on.zack Theater

BrightEye NXT 410-H Clean HDMI Router with HDCP

FS4 Quick Start Guide

Meeting Room Packages

Shouson Theatre Venue Specifications (updated Jan 2017)

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

Transcription:

MÜNCHNER KAMMERSPIELE Tech Rider KAMMER 2 (Neues Haus) Contents Stage...2 Fly system & understage...3 Lighting...4 Sound...5 Video...6 Stage management system...7 page 1/7 version: 2017-10-18

Stage Auditorium - Different setups for theatre and concert performances (see separate plans) - Variable audicence stands with 240 seats (ascent +50 cm) - platform system "Theater-Baukasten-Dresden" with 2m x 1m aluminium podiums - black benches Measurements stage ca. 18m x 24m gallery ca. 14m x 4m height ca. 8m, in front of elevator ca. 4,60m anderstage - 2,80 m gate ca. 4 m x 5 m page 2/7 version: 2017-10-18

Fly system & understage General information - Lighting galleries on the sides of the stage - There is a movable bridge between the galleries - The stage is a flexible stage (black box) so there is no offstage storageroom by default. - black curtains avialable - fly bar diameter: 50 mm - fly bars can be disconnected between their ropes. - mounting possibilities on the walls (steel supports) with M 12 threads - gallery with removable railing, black stage floor - Delivery of decorations via the depot of the Münchner Kammerspiele. Fly system stage - fly bars 1-19 automated fly system length: 11,72 m (fully extended 12,92 m) range: +0,26 m to 8,13 m max. load: 300 kp speed: 0-0,3 m/s - Panoramaf fly bars 1 4 automated fly system - (left and right, next to gallery) length: 3,20 m (with 1m extension each) range: +0,26 m to 8 m max. load: 250 kp speed: 0-0,25 m/s backstage - fly bars 20 25 automated fly system length: 11,72 m range: +0,30 m to 4,65 m max. load: 300 kp speed: 0-0,3 m/s Understage - black stage floor removable floor elements 0,5 m x 2,2 m x 8,5 cm max. load: 500 kg/m² max. point load: 350 kg/m² - deconstructable steel construction - waterconnection on understage page 3/7 version: 2017-10-18

Lighting Lighting desk 1 ETC GIO 4000, Backup about ETC Nomad 1 Dimmerroom with a total of: 42 dimmers 5kW, 218 dimmers 2,5kW and 24 non dimmable lines for HMI -Typ Transtechnik 12 2kW sinedimmers Typ Swisson DMX and Ethernet connection DMX-network configuration and DMX extention is possible via LSS Masterport DMX-feed in is possible via ETC Net3 4port Gateway 4 DMX universes via Transtechnik E-Gate Worklights control via Profibus and LSS Digiplus Toughpanel page 4/7 version: 2017-10-18

Sound Mobile speakers KS 8 x CPD 08 active systems 4 x CPD 10 active systems 6 x CPD 12 active systems 4 x CPD SUB-2, active subwoofer 2 x CPD W-1, active subwoofer 2 x CPD W-2, active subwoofer CL 106 with controlleramp CA4-U, 4 channels CPA 04, coax active speaker Mixing console Salzbrenner C.A.S.-Mix 64 digital DSP supported 64x64 matrix mixing console connected to Nexus via Madi in/out Size: 1,25m x 1,02m x 0,85m (B x H x T) FOH Position depends on audience stand setup Small mobile WLAN Remote with laptop, for controlling every parameter of the main console Playout THS (software-playout; 4x Stereo and 2x 8-track ) Ableton Live 8 and 9 with up to 16 channels at the same time via MacPro with RME RayDat 24ch. ADAT If requested: CD MD DAT Effects (FX) and Mikrophones (see Shauspielhaus) Wireless/Mikroports 6 channel Sennheiser EM 3552 receiver with 6 Belt Packs SK 50 UHF with DPA 4061 BM/FM capsules 2 Sennheiser SKM 5000 UHF handheld sender, 6 SKM 5200 with Neumann capsules 2 channel In Ear - monitoring, Sennheiser EW 300 G2 Cabling Nexus fiber optics with 2 mobile Base-Devices, connectable to various patchpanels on stage. Microphone, line, intercom, 100 Volt, speakon, optical fibre and power outlets on various patchpanels on stage. (seperate powerline for audio, isolated transformator) page 5/7 version: 2017-10-18

Video Please note: Most of our video systems are PAL standard double-check with us for NTSC playback possiblities! Projection 4x Panasonic PT-DW6300, 6000 ANSI Lumens Various lenses available. All necessary mounting plates and adressable DMX-shutters available. AV Stumpfl mobile screen 2,8x1,7m - Opera white or Optitrans AV Stumpfl mobile screen 6x4/5x3,8/4x3m - Opera white, Optitrans (only 4x3m) Other projection screens in various sizes and qualities. Connections HDMI/DVI via Lightware CAT Extenders CV/partly YC over BNC Patchbays VGA over Kramer CAT5-Extender. Playout (unstationary FOH) 2x Coolux Pandoras Box Dual Server LT Laptop with Manager Software and Widget Designer Pro* (w/ current Rev. each) MacPro 2006, 6GB RAM, 64GB SSD-RAID, Quad VGA-Output. Qlab,Isadora, Modul8 TVOne C2-7110 Dual Processor Seamless Switcher (VGA, DVI, FBAS) Kramer 6x4 VGA Matrix VP-64 1x Mixer 4In/2Out Panasonic WJ-MX20/AVE55 2x Pioneer DVD DV7300/8000 1x Matrix FBAS 32x32 Sierra Lassen/Kramer Various Consumer BD, DVD, VHS-Player *Your equipment can be controlled this setup in most cases. page 6/7 version: 2017-10-18

Stage management system Intercom Motorola GP 340 2-way wired intercom RTS mobile and fixed intercompanels with 13 possible destinations Cuelights Cuelightmatrix with 32 channels, programmable for perfomances House announcement system Separate announcements for technical staff All house speakers can give out the live onstage sound. Video Colour-, B/W-zoom, as well as infrared CCTV - cameras available on all stages. Various 14 -B/W and colour monitors available. page 7/7 version: 2017-10-18