3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE Skirt and Stabilizers

Similar documents
3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE 3M Junction Box (JBOX)

3M Distribution Box (DDB)

Cabinet Tools and Accessories Ordering Guide

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

3M Coupling Tray FDTC-10S-COUPLINGTRAY

SLiC Fiber Aerial Closure 533 and 733

3 SLiC Aerial Closure with Rubber End Seal

3M Slim Lock Closures

4320 SS-25 Self-Strip Terminating Block

3M Locator Plate N

SLiC Fiber Aerial Closure System

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

3M Cold Shrink Foldback Splice Jacket Kit

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

3M New Construction Cross-Connect Cabinets. The. Commitment. Your Copper Requires

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3M No Polish Jacketed SC/APC Connector

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

3M Better Buried Closures

3M Better Buried Compound Compression Closure System

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

18mm ECAM Cable Entry Port

3M Fiber Closures BPEO

Solutions for Electronic Specialty Markets (ESM)

3M Fiber Optic Closure System LL

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

3M 8900 Single-mode SC Crimplok Connector

Instruction Guide February 2017

3M Sensored Termination (15 kv) QX-T15I-vi1-E

3M We are Projectors! When the show must go on, 3M makes it easy:

Dynatel Advanced Cable Locator 2250

Scotch Heavy Duty Vinyl Electrical Tape 22

27mm ECAM Double Cable Entry Port

3M No Polish Jacketed SC/APC Connector

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

3M MetPak 2-FB Header

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

Built tough for long-term connections

Built tough for long-term connections

Instructions. Cable with Armor F CAUTION. October Rev A

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

3M Pressurized Closure System 2-Type 505

Communication Markets Division 3M Scotchlok Connectors and Tools. Proven. Solutions for. Today s Applications

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

3M Merchandising Catalog. Unrivaled. Product Presence to. Meet Your Merchandising Needs

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

Scotchlok Connectors and Tools

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

3M Cold Shrink Splice Kit QS-III 5416A

3M Cold Shrink Splice Kit QS-III 5515A

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Cold Shrink Splice Kit QS-III 5514A

2178 L/S Series Fiber Optic Splice Cases and Accessories

2178-L/S Series Fiber Optic Splice Case with Gasket

3M One Pass Mini Fiber Pathway

HSK Mine and Portable Cable Splice

K & B Flame Retardant Building Riser Closures

Better dispensing, better results.

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

Installation Instructions

3M Super 23 Electrical Tape

3M Mini D Ribbon (MDR) Cable Assembly

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

3M Cold Shrink Rubber Splicing Kit 5552

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

3M ScotchCode Wire Marking and Identification System. Identify with 3M

Cold Shrink Silicone Rubber Termination QT-II

FOSC 450 C6 and D6 Closures

Electrical Markets 3M ScotchCode Wire Marking and Identification System. Quality. Marking. For Most Projects

3M Cubitron. II Fibre Disc 982C and 987C Now available in grades 36+, 60+ and 80+ Engineered. Perfection. Epic Performance.

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

3 Locating and Marking Products DOCUMENT OBSOLETE

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

Size Matters: When it comes to FTTH deployment in MDUs, less is more. By Linnea Wilkes, Business Development Manager Business White Paper

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Instant 802.3af Gigabit Outdoor PoE Converter. Model: INS-3AF-O-G. Quick Start Guide

Instructions for Use of Overlap Seam Repair Kit:

IP-LINX. Installation Guide

Medium Box for Cable Termination

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

Cross-Connect Products

Quick Release Roof-Mount Kit MB700

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

LWX-1. Satellite Weather Radio Module Installation Instructions A

Installation Guide. Table of Contents: HotLok Full Rack Blanking Panel Kit. Mounting Extrusion. HotLok Blanking Panel. HotLok Blanking Sheet

Industrial Loadbreak Elbow

Installation instructions Ex frames

CGA0101 Wireless Cable Gateway Quick Installation Guide

Transcription:

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE Skirt and Stabilizers Rear skirt and stabilizers to cover and protect DSLAM apparatus cases mounted directly on 3M Pad or Stake Mount Cabinets Instructions October 2016 78-0015-2675-1-B

2 October 2016 78-0015-2675-1-B Contents 1.0 General 2.0 Accessories - Ordering information 3.0 Cabinet overall description 4.0 3M Cross-Connect Cabinet 4220SVB, 4220SVC and 4220SVE Skirt and Stabilizer Kit ordering 5.0 Stabilizer/Skirt installation for 3M 4220SVB/ 4220SVC cabinets pad or stake mount. Stabilizer/Skirt installation for SVE stake mount and Skirt installation for SVE pad mount. 6.0 Seal cable entrance 1.0 General 1.1 These instructions provide the information necessary for the installation of the rear skirt and stabilizers to the low profile 3M Cross- Connect Cabinets 4220SVB, 4220SVC or 4220SVE. The cabinets are shipped in the pad mount configuration. The 3M 4220SVB cabinet is designed to accept one external mount DSLAM, the 3M 4220SVC cabinet can accept one or two and the 3M 4220SVE cabinet can accept up to four. All of these cabinets can also house a fiber termination/ connection box and an AC powering connection box. The 3M 4220SVB and 4220SVC cabinets are multiuse in that they can be field converted as a pad, stake, and pole/post or wall mount application. The 3M 4220SVE cabinet is a multiuse in that it can be field converted as a stake or pad mount application. The cabinets accept 3M Quick Connect System (QCS) 2810 Blocks and frames (ordered separately). 1.2 Tools required for installation: a. UAE socket set b. Standard hand tools 1.3 Accessories - general a. Stake mount kit b. Pole/Post/Wall mount kit c. Rear cable entry skirt kit d. Front or rear stabilizer kit e. Rear cable entry skirt with stabilizer kit f. Top cable entry port kit g. Bottom cable entry port kit h. Internal cable sealing port kit i. 3M QCS 2810 300 maximum pair empty or loaded frame j. 3M QCS 2810 600 maximum pair loaded frame k. 3M QCS 2810 50-pair harness kits l. Fiber box m. AC power box n. Cable/pair count labels 1.4 Additional materials that may be needed for total DSLAM point installation: a. Port sealing materials b. Splicing connectors c. 3M Scotchlok Shield Bond Connector Note: The skirt and stabilizers can only be installed to the cabinets when they are in the pad or stake mount configuration. Note: The 4220SVB, 4220SVC and 4220SVE cabinets all require a specific size skirt and stabilizer. The skirt is designed to provide a confined space of protection to allow the DSLAM cables to route under and into the cabinet. (Stabilizers and Skirt are required on the 4220SVE cabinet for Stake mounting. When pad mounting the 4220SVE cabinet only the Skirt is required.)

78-0015-2675-1-B October 2016 3 2.0 Accessories Ordering Information for 3M Cross-Connect Cabinet 4220 Series 4220SVB Cabinet only 80611486061 4220SVBSK-A KIT SKIRT 80611486079 4220SVBSSK-A KIT STABILIZERS/SKIRT 80611486251 4220SVB/VB-PMK-GRADE PEDCAB BTM ENTRY GRADE/POLE MT 80611486293 4220SVB-TCPK KIT TOP CAP PORT 80611486301 4220SVB-BCPK KIT BOTTOM CAP PORT 80611486319 4220SVBS-A KIT STABILIZERS 80611498140 4220SVB-QCS/A CABINET EMPTY ALMOND 80611486244 4297-4220SVB/VB-BP KIT BREAD PAN I.D. 4"X11" 80611498132 QCS3N/300-000/A FRAME EMPTY 4220SVC Cabinet only 80611486400 4220SVC-A KIT STABILIZERS 80611486426 4220SVC-TCPK KIT TOP ENTRY PORT 80611486434 4220SVC-BCPK KIT BTM ENTRY PORT 80611486392 4297-4220SVC/VC-BP KIT BREAD PAN I.D. 4"X11" WIDE FLANGE 80611498173 4220SVCSSK-A KIT STABILIZERS/SKIRT 80611498223 4220SVCSK-A KIT SKIRT ALMOND 80611498215 4220SVC-QCS/A CABINET EMPTY ALMOND 80611481310 QCS6-QCSHC/600-000/-A FRAME EMPTY 4220SVE Cabinet only 80611486236 4220SVES-A-KIT STABILIZERS 80611498231 4220SVESK-A KIT SKIRT ALMOND 80611498181 4220SVESSK-A-KIT STABILIZERS AND SKIRT 80611498157 4220SVE-QCS/A CABINET EMPTY ALMOND All 4220SVB, 4220SVC and 4220SVE Cabinets 80611486202 4220SV/DSLAM/MB-AD-A KIT BKT OSP DSLAM MT SVB, SVC, SVE 80611486228 4220SV/DSLAM/MB-CA-A KIT BKT OSP DSLAM MT SVB, SVC, SVE 80611486095 PBO-S1-2SCA-CL KIT FIBER TERMINAL 80611498165 PBPOC-2-12-CL KIT FIBER TERMINAL 80611498199 MCFK8OD KIT MIDSPAN BOX/2 PIGTAIL, ADAPT, SBOND, GSTRAP 80611498207 4056-SVS-A STAKE MT KIT BULK ALMOND 80611498249 JBOXI INTERNAL TO CABINET 80611498256 JBOXO OUTDOOR

4 October 2016 78-0015-2675-1-B 3.0 3M Cross-Connect Cabinet Overall Description Cabinet Product Max Pair Count QCS 2810 Max # of Frames QCS 2810 Frame Number Dimensions Height/Width/Depth (inches) Single Sided Low Profile 4220SVB 300 1 QCS3N 44 7/8 x 12 3/8 x 10 1/8 X X 4220SVC 600 1 QCS6 44 7/8 x 18 x 10 1/8 X X 4220SVE 1200 2 QCS6 44 7/8 x 33 x 18 X X 4.0 3M Cross-Connect Cabinet 4220SVB, 4220SVC and 4220SVE Skirt and Stabilizer Kit ordering 4220SVB (Stabilizer not required on 4220SVE pad mount application) 80611486319 4220SVBS-A KIT STABILIZERS 80611486061 4220SVBSK-A KIT SKIRT 80611486079 4220SVBK-A KIT STABILIZERS/SKIRT 4220SVC 80611486400 4220SVC-A KIT STABILIZERS 80611498223 4220SVCSK-A KIT SKIRT ALMOND 80611498173 4220SVCSSK-A KIT STABILIZERS/SKIRT 3M Cross-Connect Cabinet 4220 SVB Stabilizers 4220SVE 80611486236 4220SVES-A-KIT STABILIZERS 80611498231 4220SVESK-A KIT SKIRT ALMOND 80611498181 4220SVESSK-A-KIT STABILIZERS AND SKIRT 3M Cross-Connect Cabinet 4220 SVB Skirt 3M Cross-Connect Cabinet 4220 SVB Skirt and Stabilizers

78-0015-2675-1-B October 2016 5 5.0 Stabilizer/skirt installation for 3M Cross-Connect Cabinets 4220SVB/4220SVC/SVE pad or stake mount (Stabilizer and skirt required for 3M 4220SVE stake mount cabinet) (Stabilizer not required, not used on 3M 4220SVE pad mount cabinet) 5.1 The skirt is designed to provide a confined space of protection to allow the DSLAM cables to route under and into the cabinet. The stabilizer can be installed on the bottom front and/or back to provide additional vertical stability to the cabinet with a DSLAM installed. The skirt will also contain the washed gravel placed in the bottom of the cabinet. 3M 4220SVE stabilizers are installed on the bottom of the cabinet and used along with the skirt for stake mount applications. The skirt and stabilizers can be ordered separately or together for the SVB and SVC cabinets and can be installed independently and each is not required to support the other. The skirt and stabilizers can be ordered separately or together for the SVE cabinet however, the stabilizers are only used on the stake mount application and must be used with a skirt. c. Install DSLAM and all cables plus field cables prior to installing skirt or stabilizer. d. Remove all installed cabinet bolts, washers and nuts required to install skirt. e. Install stabilizer first if required. f. Install skirt. Skirt Remove hardware and re-attach with skirt g. Reinstall all bolts, washers and nuts to secure skirt and stabilizer. Test probe dish JBOX I Fiber box Note: Install the bread pan cable sealing kit before routing cable if utilized. a. Confirm specific skirt and stabilizers are correct for the specific cabinet. b. 3M 4220SVE stabilizers must be mounted to the cabinet bottom first for stake mount applications. Wire spool location Ground bar Bond log label Stabilizer Stabilizer Front access cover Front access cover removed Attach stabilizers with hardware provided Stabilizers

Test probe dish JBOX I Fiber box 6.0 Seal cable entrance 6.1 Seal all cables entering the bottom of the cabinet per your company directive. 3M 4220SVB, 4220SVC, and 4220SVE Bottom Port cable entrance sealing kits 4220SVB 80611486244 4297-4220SVB/VB-BP KIT BREAD PAN I.D. 4"X9" Skirt 80611486301 4220SVB-BCPK KIT BOTTOM CAP PORT Wire spool location Ground bar Bond log label 4220SVC 80611486392 4297-4220SVC/VC-BP KIT BREAD PAN I.D. 4"X11" WIDE FLANGE Stabilizer Front access cover 80611486434 4229SVC-BCPK KIT BTM ENTRY PORT 80611488927 80611488935 4297-2-SVC PORT KIT FOR 4220SVC/VC CABINETS 4297-3-SVC PORT KIT FOR 4220SVC/VC CABINETS 4220SVE 80611487481 4297-FPE-A BREAD PAN 80610115364 4297-2 PORT ENTRY 80610115372 4297-3 PORT ENTRY 3M and Scotchlok are trademarks of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any direct, indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. Communication Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 Phone 1-800-426-8688 Web www.3m.com/telecom Please recycle. Printed in USA 3M 2016. All rights reserved. 78-0015-2675-1-B