SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Similar documents
Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Function Manual SIMATIC HMI TP900. Operator Panel.

MICROMASTER Encoder Module

KRF EMC Filters Installation, Operation and Maintenance Manual

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Power Injector 1520 Series

Photovoltaic Module Installation Manual (IEC)

Series CT7N Bimetallic Overload Relays

Photovoltaic Module Installation Manual (IEC)

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Installation Manual Original Instructions - IW4001

Trusted 40 Channel 120 Vac Digital Input FTA

SIMATIC. ET 200S distributed I/O IM151-1 BASIC interface module (6ES7151-1CA00-0AB0) Preface. Properties 1. Parameters 2. Error and system messages 3

3 Cleaning. 4 Technical data

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Trusted 40 Channel 120 Vac Digital Input FTA

SIREC P, PA, L, LA. Manual

llen-bradley 194R-HM4-NFPA3

Trusted 40 Channel Analogue Input FTA

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

Immersion Pumps HCT (High Chem) sealless

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Modular Power System acc. VG MoFess Module for Military Ground Vehicles

Cyclo Series. user manual. MartinArchitectural

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Backlight Replacement

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

LED Driver Linear / area fixed output

.Power Distribution Center. PD-1. Instruction Manual

SQM40/41 Actuators for air and gas dampers

Siemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry.

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

4 Wiring Brochure Wiring and installation of specific control

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

3 line filters for converters and power electronics

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Cisco Aironet 1520 Series Outdoor Mesh Access Point Power Injector Installation Instructions

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

SIMATIC. ET 200S distributed I/O 2AO U HS analog electronic module (6ES7135-4FB52-0AB0) Preface. Properties 1. Parameters 2.

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Operating Instructions Dimmer for V Incandescent Lamps

EMC filters. 4-line filters for installations and systems Rated current 6 to 125 A. Date: January 2006

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.


LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LED Thunder S-150 Code 1097

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

MS2540 Current Loop Receiver with RS485 Communication

DALI TOUCHPANEL BASIC TW. Operating and control unit

3M Sensored Termination (15 kv) QX-T15I-vi1-E

PRELIMINARY Sunny Boy 240-US

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

NEA WIRING CENTRE NEA HT 230V /24 V

AS09..S 3-pole Contactors - Spring Terminals

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

Heating thermostat Series AMHs B Operating Instructions 11.06/

Frequency Converter Fv

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

LED Driver Compact fixed output

Industrial Monitor Update Kit

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Model Number Structure

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

Installation Operation Maintenance

Bulletin 190 IEC Modular Starter System

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

Electric Motorized Projection Screen PowerMax Tension Series

Transcription:

SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s

Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical specifications 6 Control version V4.3 SP2 05/2010 A5E01347987A

Legal information Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation for the specific task, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed. Trademarks All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY A5E01347987A P 07/2010 Copyright Siemens AG 2010. Technical data subject to change

Table of contents 1 Safety information... 7 1.1 Warnings...7 1.2 Safety and operating instructions...8 2 General... 9 3 Mechanical installation... 15 3.1 General...15 3.2 Dimension drawings...16 4 Electrical installation... 19 5 Maintenance and servicing... 27 6 Technical specifications... 29 Operating Instructions, 05/2010, A5E01347987A 5

Table of contents 6 Operating Instructions, 05/2010, A5E01347987A

Safety information 1 1.1 Warnings WARNING Hazardous voltages are present when electrical equipment is in operation. Severe personal injury or substantial material damage may result if these warnings are not observed. Only qualified personnel are permitted to work on or around the equipment. This personnel must be thoroughly familiar with all the warnings and maintenance procedures described in these operating instructions. The successful and safe operation of this device is dependent on correct transport, proper storage and installation, as well as careful operation and maintenance. National safety guidelines must be observed. DANGER Five safety rules When carrying out any kind of work on electrical devices, the "five safety rules" defined in EN 50110 must always be observed: 1. Disconnect the system. 2. Protect against reconnection. 3. Make sure that the equipment is de-energized. 4. Ground and short-circuit. 5. Cover or enclose adjacent components that are still live. NOTICE For a UL-approved system use 60/75 C copper conductors only. Operating Instructions, 05/2010, A5E01347987A 7

Safety information 1.2 Safety and operating instructions 1.2 Safety and operating instructions DANGER This equipment is used in industrial high-voltage installations. During operation, this equipment contains rotating and live, bare parts. For this reason, they could cause severe injury or significant material damage if the required covers are removed, if they are used or operated incorrectly, or have not been properly maintained. When the machines are used in non-industrial areas, the installation location must be protected against unauthorized access (protective fencing, appropriate signs). Prerequisites Those responsible for protecting the plant must ensure the following: The basic planning work for the plant and the transport, assembly, installation, commissioning, maintenance, and repair work is carried out by qualified personnel and/or checked by experts responsible. The operating manual and machine documentation are always available. The technical specifications regarding the applicable installation, connection, environmental, and operating conditions are always observed. The plant-specific assembly and safety guidelines are observed and personal protection equipment is used. Unqualified personnel are forbidden from using these machines and working near them. This operating manual is intended for qualified personnel and only contain information and notes relating to the intended purpose of the machines. The operating manual and machine documentation are written in different languages as specified in the delivery contracts. Note We recommend engaging the support and services of your local Siemens service center for all planning, installation, commissioning and maintenance work. 8 Operating Instructions, 05/2010, A5E01347987A

General 2 Description are drive components designed for installation in electrical systems or machines. They must not be used in other electrical consumers since this could destroy the devices. WARNING must only be connected to symmetrical networks otherwise they can be destroyed. Line system configurations The line is required to comply with Class III according to EN 6100-2-4. If you want to operate the filter modules with line systems not specified in the table below, please contact our technical department. VDE-compliant line system configuration With directly grounded star point With indirectly grounded star point With isolated star point Operating the line harmonics filter Permitted Permitted Permitted Operating Instructions, 05/2010, A5E01347987A 9

General Assignment of line harmonics filter and converter G130/G150 Table 2-1 Assignment of line harmonics filter, converter G130/G150 Line harmonics filter Associated converter G130 1) Associated converter cabinet G150 2) 6SL3000-0JE36-1AA0 6SL3000-0JE38-4AA0 6SL3310-1GE33-1AAx 6SL3310-1GE33-8AAx 6SL3310-1GE35-0AAx 6SL3310-1GE36-1AAx 6SL3310-1GE37-5AAx 6SL3310-1GE38-4AAx Line voltage 380 480 V 3 AC 6SL3710-1GE33-1_Ax 6SL3710-1GE33-8_Ax 6SL3710-1GE35-0_Ax 6SL3710-1GE36-1_Ax 6SL3710-1GE37-5_Ax 6SL3710-1GE38-4_Ax Unit rating of the converter 160 kw 200 kw 250 kw 315 kw 400 kw 450 kw 6SL3000-0JE41-0AA0 6SL3310-1GE41-0AAx 6SL3710-1GE41-0_Ax 560 kw Line voltage 500 600 V 3 AC 6SL3000-0JH33-3AA0 6SL3310-1GF31-8AAx 6SL3310-1GF32-2AAx 6SL3310-1GF32-6AAx 6SL3310-1GF33-3AAx 6SL3710-1GF31-8_Ax 6SL3710-1GF32-2_Ax 6SL3710-1GF32-6_Ax 6SL3710-1GF33-3_Ax 110 kw 132 kw 160 kw 200 kw 6SL3000-0JH34-7AA0 6SL3310-1GF34-1AAx 6SL3310-1GF34-7AAx 6SL3710-1GF34-1_Ax 6SL3710-1GF34-7_Ax 250 kw 315 kw 6SL3000-0JH35-8AA0 6SL3310-1GF35-8AAx 6SL3710-1GF35-8_Ax 400 kw 6SL3000-0JH38-1AA0 6SL3310-1GF37-4AAx 6SL3310-1GF38-1AAx 6SL3710-1GF37-4_Ax 6SL3710-1GF38-1_Ax 500 kw 560 kw Line voltage 660 690 V 3 AC 6SL3000-0JH33-3AA0 6SL3000-0JH34-7AA0 6SL3310-1GH31-8AAx 6SL3310-1GH32-2AAx 6SL3310-1GH32-6AAx 6SL3310-1GH33-3AAx 6SL3310-1GH34-1AAx 6SL3310-1GH34-7AAx 6SL3710-1GH31-8_Ax 6SL3710-1GH32-2_Ax 6SL3710-1GH32-6_Ax 6SL3710-1GH33-3_Ax 6SL3710-1GH34-1_Ax 6SL3710-1GH34-7_Ax 160 kw 200 kw 250 kw 315 kw 400 kw 450 kw 6SL3000-0JH35-8AA0 6SL3310-1GH35-8AAx 6SL3710-1GH35-8_Ax 560 kw 6SL3000-0JH38-1AA0 6SL3310-1GH37-4AAx 6SL3710-1GH37-4_Ax 710 kw 6SL3310-1GH38-1AAx 6SL3710-1GH38-1_Ax 800 kw 1) With G130: only in conjunction with a line reactor and line contactor/circuit breaker (see table below) 2) With G150: only in conjunction with options L23 (line reactor) and L13 (line contactor)/l26 (circuit breaker) 10 Operating Instructions, 05/2010, A5E01347987A

General Table 2-2 Assignment of converter G130, line contactor, and line reactor SINAMICS G130 Unit rating Line contactor/circuit breaker Line reactor Line voltage 380 480 V 3 AC 6SL3310-1GE33-1AAx 160 kw 3RT1466-6AP36 6SL3000-0CE33-3AA0 6SL3310-1GE33-8AAx 200 kw 3RT1476-6AP36 6SL3000-0CE35-1AA0 6SL3310-1GE35-0AAx 250 kw 3RT1476-6AP36 6SL3000-0CE35-1AA0 6SL3310-1GE36-1AAx 315 kw 3RT1476-6AP36 6SL3000-0CE36-3AA0 6SL3310-1GE37-5AAx 400 kw 3 x 3RT1466-6AP36 6SL3000-0CE37-7AA0 6SL3310-1GE38-4AAx 450 kw 3WL1110-2BB34-4AN2-Z, Z=22 6SL3000-0CE38-7AA0 6SL3310-1GE41-0AAx 560 kw 3WL1210-2BB34-4AN2-Z, Z=22 6SL3000-0CE41-0AA0 Line voltage 500 600 V 3 AC 6SL3310-1GF31-8AAx 110 kw 3RT1456-6AP36 6SL3000-0CH32-2AA0 6SL3310-1GF32-2AAx 132 kw 3RT1456-6AP36 6SL3000-0CH32-2AA0 6SL3310-1GF32-6AAx 160 kw 3RT1466-6AP36 6SL3000-0CH32-7AA0 6SL3310-1GF33-3AAx 200 kw 3RT1466-6AP36 6SL3000-0CH33-4AA0 6SL3310-1GF34-1AAx 250 kw 3RT1476-6AP36 6SL3000-0CH34-8AA0 6SL3310-1GF34-7AAx 315 kw 3RT1476-6AP36 6SL3000-0CH34-8AA0 6SL3310-1GF35-8AAx 400 kw 3RT1476-6AP36 6SL3000-0CH36-0AA0 6SL3310-1GF37-4AAx 450 kw 3 x 3RT1466-6AP36 6SL3000-0CH38-4AA0 6SL3310-1GF38-1AAx 560 kw 3WL1210-4BB34-4AN2-Z, Z=22 6SL3000-0CH38-4AA0 Line voltage 660 690 V 3 AC 6SL3310-1GH31-8AAx 160 kw 3RT1456-6AP36 6SL3000-0CH32-2AA0 6SL3310-1GH32-2AAx 200 kw 3RT1456-6AP36 6SL3000-0CH32-2AA0 6SL3310-1GH32-6AAx 250 kw 3RT1466-6AP36 6SL3000-0CH32-7AA0 6SL3310-1GH33-3AAx 315 kw 3RT1466-6AP36 6SL3000-0CH33-4AA0 6SL3310-1GH34-1AAx 400 kw 3RT1476-6AP36 6SL3000-0CH34-8AA0 6SL3310-1GH34-7AAx 450 kw 3RT1476-6AP36 6SL3000-0CH34-8AA0 6SL3310-1GH35-8AAx 560 kw 3RT1476-6AP36 6SL3000-0CH36-0AA0 6SL3310-1GH37-4AAx 710 kw 3 x 3RT1466-6AP36 6SL3000-0CH38-4AA0 6SL3310-1GH38-1AAx 800 kw 3WL1210-4BB34-4AN2-Z, Z=22 6SL3000-0CH38-4AA0 Operating Instructions, 05/2010, A5E01347987A 11

General Line harmonics filter Figure 2-1 Line harmonics filter in the delivery condition with degree of protection IP20 12 Operating Instructions, 05/2010, A5E01347987A

General Figure 2-2 Line harmonics filter with mounted canopy and degree of protection IP21 Operating Instructions, 05/2010, A5E01347987A 13

General 14 Operating Instructions, 05/2010, A5E01347987A

Mechanical installation 3 3.1 General WARNING To ensure that the devices operate safely and reliably, they must be properly installed and commissioned by qualified personnel, taking into account the warnings provided in these operating instructions. In particular, the general and national installation and safety guidelines for high-voltage installations (e.g. VDE the Union of German Technical Engineers) as well as the guidelines relating to the proper use of tools and personal protective equipment must be observed. Death, serious injury, or substantial material damage can result if these factors are not taken into account. Note A ventilation clearance of at least 60 mm at the rear of the line harmonics filter must be observed. Natural convection must not be obstructed. Installing the canopy to increase the degree of protection to IP21 The canopy supplied can be installed on the line harmonics filter to increase the degree of protection to IP21. To install it, the spacers supplied with the line harmonics filter must be screwed into the holes otherwise used for the cover. Use the screws you removed earlier (incl. washers and retaining rings) to secure the canopy. Operating Instructions, 05/2010, A5E01347987A 15

Mechanical installation 3.2 Dimension drawings 3.2 Dimension drawings Figure 3-1 Dimension drawing of line harmonics filter: 6SL3000-0JE36-1AA0, 6SL3000-0JH33-3AA0 16 Operating Instructions, 05/2010, A5E01347987A

Mechanical installation 3.2 Dimension drawings Figure 3-2 Dimension drawing of line harmonics filter: 6SL3000-0JE38-4AA0, 6SL3000-0JH34-7AA0 Operating Instructions, 05/2010, A5E01347987A 17

Mechanical installation 3.2 Dimension drawings Figure 3-3 Dimension drawing of line harmonics filter: 6SL3000-0JE41-0AA0, 6SL3000-0JH35-8AA0, 6SL3000-0JH38-1AA0 18 Operating Instructions, 05/2010, A5E01347987A

Electrical installation 4 Important safety precautions WARNING The line harmonics filters are operated with high voltages. All connection procedures must be carried out when the cabinet is de-energized. All work on the device must be carried out by trained personnel only. Death, serious injury, or substantial material damage can result if these warnings are not taken into account. Work on an open device must be carried out with extreme caution. The power and control terminals may be live even when the motor is not running. Due to the capacitors, dangerously high voltage levels are still present in the cabinet up to five minutes after it has been disconnected. For this reason, the cabinet should not be opened until a reasonable period of time has elapsed. The operator is responsible for ensuring that the motor, converter, and other devices are installed and connected in accordance with the recognized technical rules in the country of installation and applicable regional guidelines. Special attention should be paid to cable dimensioning, fuses, grounding, shutdown, disconnection, and overcurrent protection. If an item of protective gear trips in a branch circuit, a leakage current may have been disconnected. To reduce the risk of fire or an electric shock, the current-conducting parts and other components in the cabinet unit should be inspected and damaged parts replaced. When an item of protective gear trips, the cause of the trip must be identified and rectified. When the line harmonics filter is connected to a network with a line frequency of 60 Hz, the cable jumpers must be removed in accordance with the instructions in the device (see interface overviews below). Tightening torques for connecting current-carrying parts When securing connections for current-carrying parts (e.g. copper bars), you must observe the following tightening torques. Table 4-1 Tightening torques for connecting current-carrying parts Bolt M6 M8 M10 M12 Torque 6 Nm 13 Nm 25 Nm 50 Nm Operating Instructions, 05/2010, A5E01347987A 19

Electrical installation Interface overview Figure 4-1 Connection overview of the Line Harmonics Filter (600 mm wide) 20 Operating Instructions, 05/2010, A5E01347987A

Electrical installation Figure 4-2 Connection overview of the Line Harmonics Filter (800 mm wide) Operating Instructions, 05/2010, A5E01347987A 21

Electrical installation Figure 4-3 Connection overview of the Line Harmonics Filter (1000 mm wide) 22 Operating Instructions, 05/2010, A5E01347987A

Electrical installation Connecting the Line Harmonics Filter for SINAMICS G150 L 1 L 2 L 3 N PE M 3 ~ Figure 4-4 Connecting the Line Harmonics Filter for SINAMICS G150 CAUTION Line-side protection The line harmonics filter must be line-protected! The fuses for this purpose are specified in the technical data in the SINAMICS G150 operating instructions. Operating Instructions, 05/2010, A5E01347987A 23

Electrical installation Connecting the Line Harmonics Filter for SINAMICS G130 L 1 L 2 L 3 N PE M 3 ~ Figure 4-5 Connecting the Line Harmonics Filter for SINAMICS G130 CAUTION Line-side protection The line harmonics filter must be line-protected! The fuses for this purpose are specified in the technical data in the SINAMICS G130 operating instructions. 24 Operating Instructions, 05/2010, A5E01347987A

Electrical installation Thermostatic switch connection A thermostatic switch is installed to protect the integrated reactors against overload. Its floating contacts must be integrated in the fault chain on the line side. Table 4-2 Thermostatic switch connection Terminal T1 T2 Max. connectable cross-section: 6 mm² Description of function Thermostatic switch connection Thermostatic switch connection CAUTION Shutdown following overtemperature The inverter must be switched off if the line harmonics filter overheats. This can be executed by a higher-level control. It is recommended that the temperature is evaluated internally in the converter with tripping of an OFF2 signal. For this purpose, the thermostatic switch must be supplied with 24 V DC and connected to digital input 3 (terminal -X122:4) on the Control Unit. If digital input 3 is already assigned at the factory (e.g. connected internally in the cabinet in the case of SINAMICS G150), the thermostatic switch must be wired in series with the existing signals. When the converter is commissioned, digital input DI3 is automatically connected to signal "No OFF2_2", so that when the thermostatic switch opens, an OFF2 process is initiated to shut down the converter. Figure 4-6 Thermostatic switch connection (schematic representation) Rewiring when the line frequency is changed from 50 Hz to 60 Hz When the line harmonics filter is connected to a network with a line frequency of 60 Hz, the cable jumpers must be removed in accordance with the instructions in the device (see the interface overviews). Operating Instructions, 05/2010, A5E01347987A 25

Electrical installation 26 Operating Instructions, 05/2010, A5E01347987A

Maintenance and servicing 5 Maintenance and servicing are not carried out for the line harmonics filter. If a fault occurs, please contact Technical Support. Technical support We offer technical support in both German and English for products, systems, and solutions deployed in drive and automation systems. In special cases, help is available from professional, trained, and experienced specialists via teleservice and video conferencing. Free Contact providing you with free technical support In Europe / Africa Tel.: +49 (0) 911 895 7222 Fax: +49 (0) 911 895 7223 Internet: http://www.siemens.com/automation/support-request in America Tel.: +1 423 262 2522 Fax: +1 423 262 2200 E-mail: techsupport.sea@siemens.com Asia / Pacific region Tel.: +86 1064 757 575 Fax: +86 1064 747 474 E-mail: support.asia.automation@siemens.com Operating Instructions, 05/2010, A5E01347987A 27

Maintenance and servicing 28 Operating Instructions, 05/2010, A5E01347987A

Technical specifications 6 General technical specifications Table 6-1 General technical specifications Temperature class VDE: H UL: H Cooling method AN: Air cooling by means of natural convection Line requirement Class III to EN EN 61000-2-4 Line frequency 47... 63 Hz Standards IEEE 519-1992 Paint finish RAL 7035 Ambient conditions Storage Transport During operation Ambient temperature -25... +70 C -25... +70 C 0... +50 C Relative humidity (noncondensing) corresponds to class 5... 95 % 1K4 to EN 60721-3-1 5... 95 % at 40 C 2K3 to EN 60721-3-2 5... 95 % 3K3 to EN 60721-3-3 Mechanical stability Storage Transport During operation Vibrational load: - Displacement - Acceleration corresponds to class Shock load - Acceleration corresponds to class 1.5 mm at 5 to 9 Hz 5 m/s² at > 9 to 200 Hz 1M2 to EN 60721-3-1 40 m/s² at 22 ms 1M2 to EN 60721-3-1 3.5 mm at 5 to 9 Hz 10 m/s² at > 9 to 200 Hz 2M2 to EN 60721-3-2 100 m/s² at 11 ms 2M2 to EN 60721-3-2 Deviations from the defined classes are shown in italics. 0.075 mm at 10... 58 Hz 10 m/s² at >58... 200 Hz - 100 m/s² at 11 ms 3M4 to EN 60721-3-3 Operating Instructions, 05/2010, A5E01347987A 29

Technical specifications Detailed technical specifications Table 6-2 Line Harmonics Filter, 380 V 480 V Order number 6SL3000-0JE36-1AA0 0JE38-4AA0 0JE41-0AA0 Rated power kw 315 450 560 Rated voltage - can be rewired to: V 380 V to 415 V 3 AC ±10% at 50 Hz 440 V to 480 V 3 AC ±10% at 60 Hz Rated current A 500 700 900 Power loss kw 3.09 4.54 5.6 Connection cross-sections - Maximum: IEC - Mounting hole mm 2 mm 4 x 240 15 (2 holes) 4 x 240 15 (2 holes) 4 x 240 15 (2 holes) Connection of protective conductor - Fixing bolts M12 (3 bolts) M12 (3 bolts) M12 (3 bolts) Weight kg 460 600 900 Dimensions (W x H x D) mm 600 x 1700 x 540 800 x 1700 x 540 1000 x 1700 x 540 Table 6-3 Line Harmonics Filter, 500 V 690 V, part 1 Order number 6SL3000-0JH33-3AA0 0JH34-7AA0 0JH35-8AA0 Rated power kw 315 450 560 Rated voltage - can be rewired to: V 500 V to 690 V 3 AC ±10% at 50 Hz 500 V to 690 V 3 AC ±10% at 60 Hz Rated current A 290 400 520 Power loss kw 3.11 4.62 5.69 Connection cross-sections - Maximum: IEC - Mounting hole mm 2 mm 4 x 240 15 (2 holes) 4 x 240 15 (2 holes) 4 x 240 15 (2 holes) Connection of protective conductor - Fixing bolts M12 (3 bolts) M12 (3 bolts) M12 (3 bolts) Weight kg 450 600 830 Dimensions (W x H x D) mm 600 x 1700 x 540 800 x 1700 x 540 1000 x 1700 x 540 30 Operating Instructions, 05/2010, A5E01347987A

Technical specifications Table 6-4 Line Harmonics Filter, 500 V 690 V, part 2 Order number 6SL3000-0JH38-1AA0 Rated power kw 800 Rated voltage - can be rewired to: V 500 V to 690 V 3 AC ±10% at 50 Hz 500 V to 690 V 3 AC ±10% at 60 Hz Rated current A 710 Power loss kw 7.97 Connection cross-sections - Maximum: IEC - Mounting hole mm 2 mm 4 x 240 15 (2 holes) Connection of protective conductor - Fixing bolts M12 (3 bolts) Weight kg 830 Dimensions (W x H x D) mm 1000 x 1700 x 540 Operating Instructions, 05/2010, A5E01347987A 31

Siemens AG Industry Sector Drive Technologies Large Drives Postfach 4743 90025 NUREMBERG GERMANY www.siemens.com/automation Subject to change Siemens AG 2010