Ultrasonic Probes & Accessories

Similar documents
Normal Contact Transducer is a transducer that tests putting Longitudinal Wave on vertical incidence.

Super Idea for Ultrasonic Inspection

Minimize your cost for Phased Array & TOFD

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

Minimize your cost for Phased Array & TOFD

Minimize your cost for Phased Array & TOFD

Ultrasonic Testing adapts to meet the needs of the Automotive Tube Industry

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

RPV and Primary Circuit Inspection. Pressure Vessel Inspection Codes for phased Arrays M. Moles, Olympus NDT, Canada

WheelProbe2. Simplicity Capability Reliability

WheelProbe 2. Innovation, Flexibility, Performance

AC05-76RL01830; NRC JCN N6398; Mr. Wallace Norris, Program Monitor.

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

R&S RT-Zxx High-Voltage and Current Probes Specifications

APPLICATION OF PHASED ARRAY ULTRASONIC TEST EQUIPMENT TO THE QUALIFICATION OF RAILWAY COMPONENTS

No. MME/INS/153/ Date: 27 August 2018 NOTICE INVITING TENDER

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

R&S RT-Zxx Standard Probes Specifications

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

New appraoch for X-ray weld inspection of pipeline segments

Methodical Guidelines on using 1550 IntroVisor Ultrasonic Flaw Detector with digitally focused arrays in TOMOGRAPH mode

Study on Indication pattern in Time of Flight Diffraction technique

Perfecting the Package Bare and Overmolded Stacked Dies. Understanding Ultrasonic Technology for Advanced Package Inspection. A Sonix White Paper

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

PicoScope 6407 Digitizer

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

In-process inspection: Inspector technology and concept

NONDESTRUCTIVE INSPECTION OF A COMPOSITE MATERIAL SAMPLE USING A LASER ULTRASONICS SYSTEM WITH A BEAM HOMOGENIZER

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel.

X-ray Tube Housing Assembly H1076X H1076Y Print No.HA Release Date:

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

G.R.A.S. Sound & Vibration

PicoScope 6407 Digitizer

CATEGORY 6 CABLING SOLUTIONS

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

CATEGORY 6A CABLING SOLUTIONS

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

Cover Sheet. Scanning Report of Flexible Riser Pipe Section EVI /7/2005. Inspection Report

Mechanical aspects, FEA validation and geometry optimization

R&S RT-Zxx High-Bandwidth Probes Specifications

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

ULTRASONIC FLAW DETECTOR А1220 MONOLITH OPERATION MANUAL. Acoustic Control Systems, Ltd. Moscow 2015

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

User manual. Long Range Wireless HDMI/SDI HD Video Transmission Suite

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

Product model and standard

R&S RT-ZM Modular Probe System

General Specifications

Long Range Wireless HDMI/SDI HD Video Transmission Suite LINK-MI LM-SWHD01. User manual

TECHNICAL PASSPORT OPERATION MANUAL

TR-2 OPERATION MANUAL

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

Dual Power and Control. Backup System. Armor. SUT43X Series. Ideal Solution For Control Room

50 mw green DMX laser

Quality Control. Chapter 23

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Analogue HD Monitoring Set: 8-Channel Video Recorder + 4 Outdoor Cameras

GDB-03 Demo Module USER MANUAL GW INSTEK PART NO. 82DB-03000M01 ISO-9001 CERTIFIED MANUFACTURER

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Applications protects low noise amplifiers and other devices from ESD or input power damage military, hi-rel applications

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

R&S MDS-21 Absorbing Clamp Measurement of disturbance power and screening effectiveness on cables

Scalable Low cost Ultrasound Beam former

GaAs MMIC Double Balanced Mixer

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

R&S ZN-Z154 Calibration Unit Specifications

GaAs MMIC Double Balanced Mixer

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Pressure transmitter COMPACT IO-Link,

GaAs DOUBLE-BALANCED MIXER

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

AMS 6ICT. Weather-Resistant Enclosure

Long Range Wireless HDMI/SDI HD Video Transmission Suite LINK-MI LM-SWHD01. User manual

GaAs DOUBLE-BALANCED MIXER

GaAs DOUBLE-BALANCED MIXER

Agilent 87405C 100 MHz to 18 GHz Preamplifier

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

GaAs DOUBLE-BALANCED MIXER

R&S HF907DC SHF Downconverter Specifications

IMPAC Infrared Thermometers

BID SPECIFICATION FOR PRODUCTION CRT MONITORS

SRM W 15" Portable Powered Subwoofer

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

Low Profile Digital HDTV Over-the-Air Antenna CONTENTS

DA : Series of Narrowband or Wideband Distribution Amplifiers

GaAs MMIC Double Balanced Mixer

Features wideband, 10 to 500 MHz. Applications military, hi-rel applications stabilizing generator outputs reducing amplitude variations

OSCILLOSCOPE AND DIGITAL MULTIMETER

GaAs MMIC Triple Balanced Mixer

USB-TG124A Tracking Generator User Manual

Television Analyser - TVA97

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

CATEGORY 6A CABLING SOLUTIONS

Parameter Input Output Min Typ Max Diode Option (GHz) (GHz) Input drive level (dbm)

Transcription:

Ultrasonic Probes & Accessories

Production Capability & Quality Assurance SIUI product adopts: Highly advanced manufacturing facility Rigorous production environment control Strict product testing and inspection equipment With an aim to reach advanced international level, SIUI strictly executes every step of development, purchase, production, sales and after sales service according to related international and national quality standards. The line of ultrasound probe includes normal, angle, variable-angle, dual, immersion, focusing angle-beam, broadband normal probes, composite probes, spotweld probes and custom ultrasonic probes, which can meet different application requirements of customers. In addition, OEM orders can be accepted subject to specifications and purchase quantity. Environmental Chamber International Advanced SMT Production Line World-leading Probe Inspection System Since 1995, SIUI has been certified by lots of domestic and overseas authorities. ISO9001 Certification European CE Marking China s national ultrasonic standard for equipment and probe, is drafted by SIUI Product Certification issued by Ministry of Railway An affiliated unit to the Product Quality Supervision and Test Center for Mechanical Industry Ultrasonic Instruments The only professional institute of ultrasonic instruments in China ISO9001 *EN-12668-2 compliant.

Normal Probe There are two series of normal probes for your selection: Mainly used for testing defects parallel to or slightly tilted against the test surface (e.g. steel plate) Mid Bandwidth Series Medium pulse, medium damping best combination of gain and resolution Medium Bandwidth typical -6dB bandwidth range 30%~50% Wide Bandwidth Series (Composite Materials) High signal-to-noise in composite materials Short pulse, Higher resolution than Mid series Wide Bandwidth typical -6dB bandwidth range 60%~120% P2-20L Crystal dimension 20 Crystal Size(mm) D d H Φ6 Φ16.4 Φ10.1 22 Φ10 Φ18.8 Φ13.1 24 P/M Φ13/Φ14 Φ21.4 Φ17.1 26.5 Φ19/Φ20 Φ29.2 Φ23.5 32 Φ24/Φ25 Φ32.8 Φ27.5 34 Φ30 Φ40 Φ34 42 Mid Bandwidth Series (MHz) Crystal Size (mm) 1 Φ10,Φ13,Φ14,Φ19,Φ20,Φ24,Φ25,Φ30 P 2/2.25/2.5/4/5 Φ6,Φ10,Φ13,Φ14,Φ19,Φ20,Φ24,Φ25,Φ30 10 Φ6,Φ10 Wide Bandwidth Series(Composite Materials) (MHz) Crystal Size (mm) 0.5/1 Φ19,Φ20,Φ24,Φ25Φ29 M 2/2.25/2.5 Φ10,Φ13,Φ14,Φ19,Φ20,Φ24 4/5 Φ6,Φ10,Φ13,Φ14,Φ19,Φ20 *LEMO 01 is only available for those crystal size 24mm. *Probes with crystal size 6mm are only compatible with LEMO 00 and Microdot.

Replaceable Membrane Normal Probe There are two series of Replaceable Membrane Normal probes for selection: Mid Bandwidth Series Medium Pulse and Medium Damping perfect combination of gain and resolution Medium Bandwidth typical -6dB bandwidth range 30%~50% Wide Bandwidth Series Higher Penetration, Higher Signal-to-noise, Higher Resolution, Higher Sensitivity than Mid Freq Series Medium Bandwidth typical -6dB bandwidth range 60%~120% Mainly used for inspecting container flaws as well as flaws parallel to the inspected surface,applicable for checking coarse and slightly-curved surfaced objects. RB2-25L Crystal dimension 25 Crystal Size(mm) D d H Φ10 Φ21 Φ14 25.8 RB/RP/RM Φ13/Φ14 Φ24 Φ17 28 Φ19/Φ20 Φ36 Φ24 40.5 Φ24/Φ25 Φ46 Φ30 52 Mid Bandwidth Series (Recommended) (MHz) Crystal Size (mm) 0.5/ 1 Φ19,Φ20,Φ24,Φ25Φ29 RB 2/2.25/2.5 Φ10,Φ13,Φ14,Φ19,Φ20,Φ24 4/5 Φ6,Φ10,Φ13,Φ14,Φ19,Φ20 Mid Bandwidth Series (Based on P series normal probe with membrane protection) (MHz) Crystal Size(mm) RP 1/2/2.25/2.5/4/5 Φ10,Φ13,Φ14,Φ19,Φ20,Φ24,Φ25 Wide Bandwidth Series (MHz) Crystal Size (mm) 0.5/1 Φ19,Φ20,Φ24,Φ25,Φ29 RM 2/2.25/2.5 Φ10,Φ13,Φ14,Φ19,Φ20,Φ24 4/5 Φ6,Φ10,Φ13,Φ14,Φ19,Φ20 *LEMO 01 is only available for those crystal size 24mm.

Replaceable Delay Line Normal Probe D2.5-10L Crystal dimension 10 D Series Mainly used for inspecting flaws parallel to/ near to the inspected object surface, applicable for inspected objects with sharp edge.if the delay line is made of high-temperature material, it can also inspect high-temperature objects. DM Series Crystal Size(mm) D d H Φ10 Φ18 Φ11 30 D/DM Φ14 Φ22 Φ15 32 Φ20 Φ29 Φ21 38 Φ24 Φ33 Φ25 44 Crystal Size(mm) D d H Φ3 Φ12 Φ4 26 DM Φ6 Φ14.5 Φ8 28.8 Mid Bandwidth Series (MHz) Crystal Size (mm) D 2/2.25/2.5/4/5 Φ10,Φ14,Φ20,Φ24 Wide Bandwidth Series (MHz) Crystal Size (mm) 2/2.25/2.5 Φ10,Φ14 L: LEMO 00/ DM 4/5 Φ6,Φ10 7.5/ 10 Φ3,Φ6 * 7.5/10Mhz is also available, please refer to Thickness Gauge Probe series *Probes with crystal size 3mm are only compatible with Microdot.

Angle Probe ( Transverse Wave ) There are two series of Transverse Angle probes for selection: Narrow Bandwidth Series General purpose, recommended for the majority of applications Medium Bandwidth typical -6dB bandwidth range from 20%~30% Mid Bandwidth Series Medium Pulse, Medium Damping best combination of gain and resolution Medium Bandwidth typical -6dB bandwidth range from 30%~50% AFN4-89-60L Crystal dimension 8 9 Angle Crystal Size(mm) L W H 6 6 24.5 12.5 18 AFN/AFP 8 9/10 10 28.5 14.8 24 14 14/14 16 40.2 20.5 31 20 20/20 22 52 26.5 39 Narrow Bandwidth Series (MHz) Crystal Size (mm) Angle AFN 2/2.25/2.5/4/5 6 6, 8 9, 10 10,14 14, 14 16, 20 20, 20 22 45,60,70 Mid Bandwidth Series (MHz) Crystal Size (mm) Angle AFP 2/2.25/2.5/4/5 6 6, 8 9, 10 10,14 14, 14 16, 20 20, 20 22 45,60,70 *LEMO 01 is only available for crystal size 20 20mm and 20 22mm. *Probes with crystal size 6 6mm are only compatible with LEMO 00 and Microdot.

Angle Probe ( Longitudinal Wave ) There are two series of Longitudinal Angle probes for selection: Narrow Bandwidth Series General purpose, recommended for the majority of applications Medium Bandwidth typical -6dB bandwidth range from 20%~30% Mid Bandwidth Series Medium Pulse, Medium Damping best combination of gain and resolution Medium Bandwidth typical -6dB bandwidth range from 30%~50% LFP2-1010-70L Crystal dimension 10 10 Angle Crystal Size(mm) L W H 6 6 24.5 12.5 18 LFN/LFP 8 9/10 10 28.5 14.8 24 14 14/14 16 40.2 20.5 31 20 20/20 22 52 26.5 39 Narrow Bandwidth Series (MHz) Crystal Size (mm) Angle LFN 2/2.25/2.5/4/5 6 6, 8 9, 10 10,14 14, 14 16, 20 20, 20 22 45,60,70 Mid Bandwidth Series (MHz) Crystal Size (mm) Angle LFP 2/2.25/2.5/4/5 6 6, 8 9, 10 10,14 14, 14 16, 20 20, 20 22 45,60,70 *LEMO 01 is only available for crystal size 20 20mm and 20 22mm. *Probes with crystal size 6 6mm are only compatible with LEMO 00 and Microdot.

Thickness Gauge Probe High Temperature Probe (Up to 200 ) Twin Crystal Probe Delay Line Probe TG2-12L Crystal dimension 12 Mainly used for measuring work piece thickness. Twin crystal (H for High temperature) Crystal Size(mm) D d H Φ6 Φ14.5 Φ9.5 27.5 TG Φ8/Φ10 Φ18 Φ11.5 27.5 Φ12 Φ22.8 Φ16.3 26.5 Crystal Size(mm) D d H TG Φ10(H) Φ42 Φ11.7 67 (MHz) Crystal Size (mm) 2 Φ12 TG 5 Φ6,Φ8,Φ10 Φ10 (H) L: LEMO 00/ 7.5 Φ6 Single crystal (N for normal probe, which also be used for flaw detectors) Crystal Size(mm) D d H TG Φ20(N) Φ28 Φ26 45 (MHz) Crystal Size (mm) TG 1/ 2.5 Φ20(N) Single crystal (D for delay line probe, wide frequency series) Crystal Size(mm) D d H Φ3(D) Φ12 Φ4 26 TG Φ6(D) Φ14.5 Φ8 28.8 (MHz) Crystal Size (mm) 5 Φ6(D) L: LEMO 00/ TG Φ3(D) 7.5/10 Φ6(D) L: LEMO 00/ *All twin crystal TG probes are with cable.

Angle Probe With Replaceable Wedge There are two types for selection: Mid Bandwidth Series General purpose, recommended for most applications Medium Pulse & Medium Damping perfect combination of gain and resolution Medium Bandwidth typical -6dB bandwidth range from 30%~50% Wide Bandwidth Series Gain is usually higher than Mid Freq Series Wide Bandwidth typical -6dB bandwidth range from 60%~120% Snail Wedge ADP2-1616-70L Angle Crystal dimension 16 16 Crystal Size(mm) D d H Φ3/Φ6 Φ11 Φ9 25 ADP/LDP/ADM/LDM Φ10 Φ17 Φ14.5 23 Φ13/Φ14 Φ19 Φ16.8 24 ADM/LDM Φ20 Φ26 Φ24 31 Crystal Size(mm) L W H 13 25 47 19 30 ADP/LDP/ADM/LDM 16 16/16 19 47 25 30 Mid Bandwidth Series (Transverse Wave ADP and Longitudinal Wave LDP) (MHz) Crystal Size (mm) Angle ADP LDP 2/2.25/2.5/4/5 13 25, 16 16, 16 19,Φ6,Φ10, Φ13 45,60,70 7.5/10 Φ6 Wide Bandwidth Series (Transverse Wave ADM and Longitudinal Wave LDM) (MHz) Crystal Size (mm) Angle ADM LDM 2/2.25/2.5/4/5 13 25, 16 16, 16 19,Φ6,Φ10,Φ13, Φ14 7.5/10 Φ3,Φ6 45,60,70 *Crystal size unit inch is also available: 1/4, 3/8, 1/2. *Probes with crystal size 6mm are only compatible with LEMO 00 and Microdot. *Probes with crystal size 3mm are only compatible with Microdot.

Dual-Element Angle Probe For TRANSVERSE WAVE type: Mainly used for testing small near-surface defects, thin wall pipe and ring-type work piece. For LONGITUDINAL WAVE type: Mainly used for macro-crystal welding inspection, attenuating material and Austenitie welding. For 70 degree angle, it can be applied for creeping wave. Mainly used for testing defects tilted against the test surface or perpendicular to the test surface TRT2-1010-70L Crystal dimension 10 10 Angle Crystal Size(mm) L W H 7 10 29 15 25 TRT/TRTM/TRL/TRLM 10 10 29 17 25 20 20 37 27 28 TRANSVERSE WAVE angle probes option: Narrow Bandwidth Series TRT (MHz) Crystal Size (mm) Angle TRT 2/4 7 10, 10 10, 20 20 45,60,70 L: LEMO 00 Wide Bandwidth Series TRTM (MHz) Crystal Size (mm) Angle TRTM 2/4 10 10, 20 20 45,60,70 L: LEMO 00 LONGITUDINAL WAVE angle probe option: Narrow Bandwidth Series TRL (MHz) Crystal Size (mm) Angle TRL 2/4 7 10, 10 10, 20 20 45,60,70 L: LEMO 00/ Wide Bandwidth Series TRLM (MHz) Crystal Size (mm) Angle TRLM * All crystal sizes is for twin-element crystals. 2 4 10 10, 20 20 45,60,70 L: LEMO 00

Dual-element Normal Probe Mainly used for testing defects parallel to or slightly tilted against the test surface (e.g. steel plate); Much more appropriate for detecting near surface flaws than normal probes. * Side connector is available. (Please specify when order) TR2.5-14-30L Crystal dimension 14 Focal Length Narrow Bandwidth Series Wide Bandwidth Series Crystal Size(mm) D d H TR/TRM Φ10/7 10 Φ28 Φ14.5 40 Φ14/10 10 Φ28 Φ19.6 36.5 Φ20/14 18/12 20 Φ31 Φ25.5 40.5 Φ24/20 20 Φ35 Φ29 47 (MHz) Crystal Size (mm) Focal Length (mm) TR 2/2.25/2.5 4/5 Φ10 None,10 Φ14,Φ20,Φ24 None,10,20, 30 14 18, 12 20, 10 10, 20 20 Φ10 None,10,20 None,10,20 Φ14,Φ20,Φ24 None,10,20, 30 7 10 None,10, 15 L: LEMO 00 (MHz) Crystal Size (mm) Focal Length (mm) TRM * TR probes with membrane is also available. 2/2.25/2.5 4/5 Φ10 None,10 Φ14,Φ20,Φ24 None,10,20, 30 14 18, 12 20 None,10,20 Φ10 None,10,20 Φ14,Φ20,Φ24 None,10,20, 30 7 10, 10 10, 20 20 None,10, 15 L: LEMO 00 * All crystal sizes is for twin-element crystals.

Immersion Probe There are two series of Immersion probes for selection Mid Bandwidth Series General purpose, recommended for the majority of applications Medium Bandwidth typical -6dB bandwidth range from 30%~50% Wide Bandwidth Series High signal-to-noise in composite materials Short Pulse, Higher resolution than Narrow series Wide Bandwidth typical -6dB bandwidth range 60%~120% Mainly used in situations where the work piece and the probe do not contact directly. It is suitable for testing work piece with rough surface and automatic testing required to increase scanning speed and shorten testing time. ICP4-10-20L Crystal dimension 10 Focal Length Mid Bandwidth Series Immersion Probe without Focusing Immersion Probe with Line Focusing (MHz) Crystal Size (mm) Focal Length (mm) Φ6 10 Immersion Probe with Point Focusing Crystal Size(mm) D d H Φ6 Φ12 Φ9 40 Φ10 Φ16 Φ13 46 INP/ICP/ISP/INM/ICM/ISM Φ13/Φ14 Φ20 Φ17 52 Φ19/Φ20 Φ26 Φ23 58 Φ24/Φ25 Φ31 Φ28 64 (MHz) Crystal Size (mm) Focal Length (mm) INP 2/2.25/4/5 ICP Φ6,Φ10,Φ13,Φ14, Φ19,Φ20,Φ24,Φ25 None 2/2.25/2.5 Φ10,Φ13,Φ14, Φ19,Φ20,Φ24,Φ25 10,20,30 Φ6 10,20 4/5 Φ10,Φ13,Φ14, Φ19,Φ20,Φ24,Φ25 10,20,30 (MHz) Crystal Size (mm) Focal Length (mm) Φ6 10 ISP 2/2.25/2.5 Φ10,Φ13,Φ14, Φ19,Φ20,Φ24,Φ25 10,20,30 Φ6 10,20 4/5 Φ10,Φ13,Φ14, Φ19,Φ20,Φ24,Φ25 10,20,30

Wide Bandwidth Series Immersion Probe without focusing (MHz) Crystal Size (mm) Focal Length (mm) INM 2/2.25/4/5 Immersion Probe with Line Focusing Immersion Probe with Point Focusing Φ6,Φ10,Φ13,Φ14, Φ19,Φ20,Φ24,Φ25 None (MHz) Crystal Size (mm) Focal Length (mm) ICM 2/2.25/2.5 Φ10,Φ13,Φ14, Φ19,Φ20,Φ24,Φ25 Φ6 10 10,20,30 Φ6 10,20 4/5 Φ10,Φ13,Φ14, Φ19,Φ20,Φ24,Φ25 10,20,30 (MHz) Crystal Size (mm) Focal Length (mm) φ6 10 ISM 2/2.25/2.5 φ10,φ13,φ14, φ19,φ20,φ24,φ25 10,20,30 φ6 10,20 4/5 φ10,φ13,φ14, φ19,φ20,φ24,φ25 10,20,30 Variable-angle Probe The reflection angle can be adjusted to meet different requirements. AV2.5-1016L Crystal dimension 10 6 Crystal Size(mm) L W H 10 8 60 29 37.5 AV 10 16 75 33 42 (MHz) Crystal Size (mm) Angle AV 2.5/5 10 8, 10 16 45,60,70

Surface Wave Probe AS2.5-66L Crystal dimension 6 6 Mainly used for surface defect testing and also for surface crack depth testing. Crystal Size(mm) L W H 6 6 24.5 12.5 18 AS 10 10 28.5 14.8 24 (MHz) Crystal Size (mm) AS 2.5/5 6 6, 10 10 L: LEMO 00/ Spot-Weld Probe SW15-3L Crystal dimension 3 Straight-beam probe with soft protective membrane, using water column as water delay coupling, so as to achieve optimal coupling between the probe and spot weld surface. Especially good for spot-weld testing on thin plates of automotive industry. Crystal Size(mm) D H SW Φ3/Φ4/Φ5/ Φ6/Φ7/Φ8 Φ16 33 (MHz) Crystal Size(mm) SW 15 Φ3,Φ4,Φ5,Φ6,Φ7,Φ8 L: LEMO 00 /

Custom Ultrasonic Probe SIUI can provide custom ultrasonic probes according to specific requirement. Probe Cable SIUI provides various of probe cables to be compatible with probes. There are different kinds of cable connectors for your selection. Such as BNC, LEMO 01, LEMO 00, Microdot, UHF etc. Probe Test Report Probe test reports are available as option. (EN 12668-2 compliant) Storage Boxes Storage boxes are available for all of our UT probes.

Shantou Institute of Ultrasonic Instruments Co., Ltd. Add: #77, Jinsha Road, Shantou 515041, Guangdong, China Tel: +86-754-88250150 Fax: +86-754-88251499 E-mail: siui@siui.com Website: http://www.siui.com Specifications and appearance are subject to change without prior notice. DCY2.791.UT PROBE.CY/7E05