SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Similar documents
Flow Measurement SITRANS F M

Flow Measurement SITRANS F M

SITRANS F M. Transmitter MAG 5000/6000 4/33

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Level Measurement Continuous level measurement - Capacitance transmitters

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Capacitance Level Measurement Electronic insert FEC 12

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

TFRH Hygienic RTD temperature sensor. CombiTemp TM

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Level Measurement Point level measurement - RF Capacitance switches

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Level Measurement Point level measurement RF Capacitance switches

Inductive sensor With analog output BI15-M30-LI-EXI

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Process transmitter RMA422

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor BI1.5-EG08K-Y1

Pendant Light Fitting IEC Series 6470/2

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

TFRN Industrial RTD temperature sensor. CombiTemp TM

Process Transmitter RMA 422

Inductive sensor NI10-M18-Y1X-H1141

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/224 Siemens FI Overview.

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

DMP 331i / DMP 333i LMP 331 i

AF-300 E11 Adjustable Frequency Drive

Wall-/Pipe-Mount Level Indicator

Level Measurement silometer FMC 420, FMC 423

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

TFR5 Room or outdoor temperature sensor. CombiTemp TM

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Liquid Level Sensor Type AKS 4100U

Linear flow controls VFC Linear flow controls with actuator IFC

7 Lighting Technology

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Dissolved Oxygen Transmitter

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

FLOMAT Electromagnetic Insertion Flowmeter

Explosion Proof Audible Signal db(a) Series YA60

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Level Measurement Continuous level measurement Radar transmitters

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

RMA42. Technical Information

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Dissolved Oxygen Transmitter

Level Measurement Continuous level measurement Radar transmitters

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Liquid Level Sensor AKS 4100U

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Lt DELTA USA, Inc

Type AKS 4100/4100U Coaxial D14 version

PROPORTIONAL VALVES Sentronic plus

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

2.9 Sigma/ 2 Plunger Metering Pumps

Single Point Flow Monitor SW118 SW119

EXLUX ECOLUX C-LUX 6480 Series

EXLUX ECOLUX 6480 Series

Mechanical flow switch for On/Off control

Pendant Light Fittings Series 6050

Datasheet EC-750 Ex DOME Camera

Fibre Optic Modem ODW-611

Linear flow control with actuator IFC

2291 Guided Wave Radar Level Transmitter

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Liquid Level Sensor AKS 4100U

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Linear encoders without bearings incremental System for linear motion feedback

Modular Lube Lubrication Systems System Controls

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Viper Ex the hazard free way to precise weighing results. Ex ia. The intrinsically safe compact scales combine leadingedge

Liquid Level Sensor Type AKS 4100/4100U

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Technical data. General specifications. Indicators/operating means

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

XML LED X M L L E D. Explosionproof Linear LED Lighting

Transcription:

Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments. Full input and output functionality is given even in the Ex version. Benefits Full range of ATEX rated flowmeters with intrinsically safe rated input and outputs For compact or remote installation HART, FOUNDATION Fieldbus H1, DeviceNet, PROFIBUS PA and DP, MODBUS RTU/RS85 addon communication modules available Superior signal resolution for optimum turn down ratio Digital signal processing with many possibilities Automatic reading of SENSORPROM data for easy commissioning User configurable operation menu with password protection 3 lines, 20 characters display in 11 languages Flow rate in various units Totalizer for forward, reverse and net flow as well as much more information available. Multiple functional outputs for process control, minimum configuration with analogue, pulse/frequency and relay output (status, flow direction, limits) Comprehensive selfdiagnostic for error indication and error logging Batch control Design The transmitter is designed for either compact or remote installation in nonhazardous or hazardous areas (compact mounted transmitter to be ordered together with the sensors). Function The following functions are available: Flow rate 2 measuring ranges 2 totalizers Low flow cutoff Flow direction Error system Operating time Uni/bidirectional flow Limit switches and pulse output Batch control The MAG 6000 I/6000 I Ex d is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic sensors and also fulfil the task of a power supply unit which provides the magnet coils with a constant current. Further information on connection, mode of operation and installation can be found in the data sheets for the sensors. Displays and keypads Operation of the transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication PC/laptop and SIMATIC PDM software using PROFIBUS or MODBUS communication Technical specifications Mode of operation and design Measuring principle Empty pipe Excitation frequency Electrode input impedance Input Digital input Activation time Current Output Current output Signal range Load Digital output Frequency Pulse (passive) Relay output Load Low flow cut off Galvanic isolation Max. measuring error MAG 6000 I/MAG 6000 I Ex d (incl. sensor) Electromagnetic with pulsed constant field Detection of empty pipe (special cable required in remote mounted installation) Depend on sensor size > 1 x 10 1 Ω DC 11... 30 V, Ri =. kω 50 ms I 11 V DC = 2.5 ma, I 30 V DC = 7 ma 0... 20 ma or... 20 ma (active/ passive) < 560 Ω 0 10 khz, 50% duty cycle (uni/bidirectional) 3 30 V DC, max 110 ma (30 ma Ex version), 200 Ω Ri 10 kω (powered from connected equipment) Changeover relay, same as current output 2 V AC/2 A, 2 V DC/1 A 0 9.9% of maximum flow All inputs and outputs are galvanic isolated ±0.2 % ±1 mm/s /3

Siemens AG 2009 Rated operation conditions Ambient temperature Operation MAG 6000 I 20 60 C ( 10 F) MAG 6000 I Ex 10 60 C (1 10 F) Storage 0 70 C (0 158 F) Mechanical load 18... 1000 Hz random in x, y z, directions for 2 hours according to EN 60068236 Transmitter: 1.1 grms Degree of protection IP67/NEMA X to IEC 529 and DIN 0050 (1 mh 2 O 30 min.) EMC performance EN 61326 Display and keypad Totalizer Two eightdigit counters for forward, net or reverse flow Display Background illumination with alphanumeric text, 3 x 20 characters to indicate flow rate, totalized values, settings and faults; Reverse flow indicated by negative sign Keypad Capacitive touch keypad with LED light for feedback indication as current output time constant Design Enclosure material Die cast aluminium, with corrosion resistant Basic Polyester power coating (min. 60 µm) Wall mounting Wall mounting bracket enclosed for remote version Dimensions See dimensional drawings Weight See dimensional drawings Power supply Non Ex d: 18... 90 V DC; 115... 230 V AC; 50... 60 Hz Ex d: 18... 30 V DC Ex d: 115... 230 V AC; 50... 60 Hz Power consumption 230 V AC: 21.5 VA 2 V DC: 12 W, I N = 380 ma, I ST = 1 A (3 ms) Certificates and approvals MAG 6000 I CE Ctick FM class 1, div 2 FM class 1, zone 2 CSA class 1, div 2 CSA class 1, zone 2 MAG 6000 I Ex IEC Ex de [ia] [ib] ia IIC T6 Gb Ex tda 21 IP67 ATEX II 2(1)(2) GD EEx de [ia] ia [ib] IIC T6 FM class 1, zone 1 CSA class 1, zone 1 Cable entries Remote installation MAG 6000 I 2 x M25(for supply/output) and 2 x M16 (for sensor connection) or 2 x ½" NPT (for supply/output) and 2 x M16 (for sensor connection) MAG 6000 I Ex ATEX 2G D 2 x M20 (for supply/output) and 2 x M16 (for sensor connection) Communication Non ATEX versions HART, MODBUS RTU/RS 85, FOUNDATION Fieldbus H1, DeviceNet, PROFIBUS PA, PROFIBUS DP addon modules ATEX 2G D HART, PROFIBUS PA, FOUNDATION Fieldbus H1 available as integrated version Selection and Ordering data Transmitter MAG 6000 I / Ex d Remote, local display, die cast aluminium Communication modules for MAG 6000 I (All standard outputs can still be used) HART FDK085U0321 (only for MAG 6000 I/Ex) MODBUS RTU/RS85 FDK085U023 PROFIBUS PA Profile 3 FDK085U0236 PROFIBUS DP Profile 3 FDK085U0237 DeviceNet FDK085U0229 FOUNDATION Fieldbus H1 A5E0205250 7 M E 6 9 3 0 2 B A 7 7 1 7 A 7 Supply voltage 115... 230 V AC, 50... 60 Hz; 18... 90 V DC 2 ATEX 2G D, 18... 30 V DC ATEX 2G D, 115... 230 V AC, 50... 60 Hz 5 Ex approval None ATEX; FM/CSA class1 div 2 0 ATEX 2G D (For ATEX sensors: 7ME6110, 2 7ME6120, 7ME610, 7ME6310, 7ME6320, 7ME630) Communication None (addon modules can be ordered separately, A see below) HART B PROFIBUS PA Profile 3 F PROFIBUS DP Profile 3 (not ATEX version) G MODBUS RTU/RS 85 (not ATEX version) E FOUNDATION Fieldbus H1 J Cable gland entries Metric 0 ½" NPT 2 This device is shipped with a Quick Start guide and the SITRANS F manual CD containing the complete manual library. Printed Operating Instructions are available for purchase via PMD. Selection and Ordering data Further design Please add Z to and specify Order code(s) and plain text. Tag name plate, stainless steel fixed with SS wire (add plain text) Tag name plate, plastic (self adhesive) Other, postproduction requirements (add plain text) Order code Y17 Y18 Y99 /

Accessories MAG 6000 I / MAG 6000 I Ex d e Cable for standard electrode or coil, 3 x 1.5 mm²/ 18 gage with shield PVC FDK083F0121 FDK083F0210 0 m (130 ft) FDK083F0211 FDK083F0212 FDK083F0213 FDK083F3052 FDK083F3053 FDK083F305 Electrode cable for empty pipe or low conductivity, double shielded, 3 x 0.25 mm² (cannot be used for Ex applications) FDK083F3020 FDK083F3095 0 m (130 ft) FDK083F309 FDK083F3093 FDK083F3092 FDK083F3056 FDK083F3057 FDK083F3058 Cable kit with standard coil cable, 3 x 1.5 mm²/18 gage with shield PVC and electrode cable double shielded, 3 x 0.25 mm² 5 m (16 ft) A5E02296329 A5E0118167 15m(9ft) A5E022966 A5E01181656 25m(82ft) A5E0229690 30m(98ft) A5E022969 0 m (130 ft) A5E01181686 50 m (16 ft) A5E0229698 A5E01181689 A5E01181691 A5E01181699 A5E01181703 A5E01181705 Low noise electrode coax cable for low conductivity and high vibration levels of cables, 3 x 0.13 mm 2 2 m (6.6 ft) A5E02272692 5 m (16.5 ft) A5E02272723 A5E02272730 Spare parts Display FDK085U3122 Accessory bag including FDK085U31 cable gland inserts coil & electrode connectors Electronics cover with Ex glass A5E02593565 plate Cover for connection board incl. gasket (for remote version) Cover for mains supply/communication Safety clamp Standard wall mounting bracket Special wall/pipe mounting bracket kit 7ME59330AC02 7ME59330AC03 7ME59330AC06 7ME59330AC0 7ME59330AC05 /5

Siemens AG 2009 Complete spare part PCB unit MAG 6000 I (Not ATEX) MAG 6000 I Ex d 18... 30 V DC Spare PCB unit for use with ATEX sensors with increased safety e (For ATEX sensors: 7ME6110, 7ME6120, 7ME610, 7ME6310, 7ME6320, 7ME630) (For 7ME6330 > DN300) MAG 6000 I Ex d 115... 230 V AC Spare PCB unit for use with ATEX sensors with increased safety e (For ATEX sensors: 7ME6110, 7ME6120, 7ME610, 7ME6310, 7ME6320, 7ME630) (For 7ME6330 > DN300) Ex d version 18... 30 V DC for sensors with intrinsic safety ib 7ME633 and 7ME613 (For sensors DN 300 (12"): 7ME6130, 7ME6150 and 7ME6330) Ex d version 115... 230 V AC for sensors with intrinsic safety ib 7ME633 and 7ME613 (For sensors DN 300 (12"): 7ME6130, 7ME6150 and 7ME6330) FDK085U3123 A5E0101330 A5E01013127 FDK085U312 FDK085U3125 Please use online Product selector to get latest updates. Product selector link: www.piaselector.automation.siemens.com Please also see www.siemens.com/sitransfordering for practical examples of ordering Dimensional drawings 205 (8.07) Dimensions in mm (inch) 205 (8.07) 100 (3.9) 220 (8.66) 65 (2.56) 153 (6.08) 250 (9.8) 28 (9.76) 28 (9.76) Ø 80 (3.15) 98,5 (3.88) 153 (6.08) 33,5 (1.32) Ø 80 (3.15) Dimensions in mm (inch), weight: 6 kg (13.5 lbs) /6

Schematics Transmitter Power supply L 1 N 31 32 L Ex 18 30 V DC Ex 115 230 V AC N Non Ex 1890 V DC/ 115230 V DC PE Output Active current output Passive current output (Powered from transmitter) (External powered) Factory setting non Ex Factory setting Ex Passive output (External powered) 56 57 Menu setup: Digital output 0/20 ma Load 560 Ω Vx 330 V max. 110 ma PLCDigital Input Negativ: R 20 ma Load 560 Ω PLCDigital Input Positiv: Ω 91 92 93 9 95 96 97 Reserved for communication modules 5 6 Relay output 77 78 82 0 83 Sensor connection Electrode cable 85 86 Coil cable /7