3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Similar documents
3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

SLiC Fiber Aerial Closure System

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

3M Distribution Box (DDB)

2178-L/S Series Fiber Optic Splice Case with Gasket

18mm ECAM Cable Entry Port

3 SLiC Aerial Closure with Rubber End Seal

3M Better Buried Compound Compression Closure System

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

3M Better Buried Closures

27mm ECAM Double Cable Entry Port

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

3M Coupling Tray FDTC-10S-COUPLINGTRAY

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

FOSC 450 C6 and D6 Closures

SLiC Fiber Aerial Closure 533 and 733

Instructions. Cable with Armor F CAUTION. October Rev A

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

3M Fiber Closures BPEO

3M Fiber Optic Closure System LL

3M Cold Shrink Foldback Splice Jacket Kit

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

3M Locator Plate N

2178 L/S Series Fiber Optic Splice Cases and Accessories

INSTALLATION INSTRUCTIONS

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

HCS - HES Cabling Systems

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Pressurized Closure System 2-Type 505

3M Cold Shrink Splice Kit QS-III 5515A

K & B Flame Retardant Building Riser Closures

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

Instruction Guide February 2017

3M Cold Shrink Splice Kit QS-III 5514A

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Cold Shrink Splice Kit QS-III 5416A

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

Flexible Fiber Management Solutions

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

3M No Polish Jacketed SC/APC Connector

3M Fiber Optic Splice Closure 2178 Family. Flexible Fiber. Management Solutions

3M 8900 Single-mode SC Crimplok Connector

3M Cold Shrink Rubber Splicing Kit 5552

Medium Box for Cable Termination

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

3M Slim Lock Closures

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE 3M Junction Box (JBOX)

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

3M Sensored Termination (15 kv) QX-T15I-vi1-E

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

Optical Distribution Box 300 Installation Guide. Version : R0.0

HSK Mine and Portable Cable Splice

Scotch Heavy Duty Vinyl Electrical Tape 22

Cold Shrink Silicone Rubber Termination QT-II

Solutions for Electronic Specialty Markets (ESM)

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

Quick Term II Silicone Rubber Termination Kits for Shielded Cables Instruction Sheet

Cabinet Tools and Accessories Ordering Guide

3M No Polish Jacketed SC/APC Connector

Customer-Owned Outside Plant

IP-LINX. Installation Guide

Installation Instructions

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE Skirt and Stabilizers

4320 SS-25 Self-Strip Terminating Block

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Gel-sealed in-line fiber optic closure

Industrial Loadbreak Elbow

INSTALLATION INSTRUCTIONS

IP-LINX Fiber :: X-XXXX

Fiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

TECHNICAL SPECIFICATION

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

Fiber Optic Splice Closure GPJ Instruction Manual

Scotchlok Connectors and Tools

3M One Pass Mini Fiber Pathway

Ordering Guide of the Fiber-Optic Splice Closure (FOSC-400)

SPECIFICATION. Spec No : VSS-1402-CS603B

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits

3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0

3M Super 23 Electrical Tape

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

Splice Closure Fiber (SCF) Family

Installation instructions Roxtec RM ES

Transcription:

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR Instructions July 2010 78-8135-0094-5-K 3

1.0 General 1.1 3M Fiber Optic Splice Closure 2178-XSB The 3M Fiber Optic Splice Closure 2178-XSB has been developed to accommodate up to 48 single fusion splices, and 144 mass fusion splices. The closure has two 1" ports and one 1.4" port in the center. The 2178-XSB splice closure can accommodate two 3M Fiber Optic Splice Trays 2532. The 2532 splice tray can accommodate single fusion, single mechanical or 12-ribbon fiber. 2178-XSB Height 4.62" (117 mm) 2178-XLB Height 5.75" (146 mm) 2181 Adapter adds 2.05" (52 mm) Width 10.10" (257 mm) 1.2 3M Fiber Optic Splice Closure 2178-XLB The 3M Fiber Optic Splice Closure 2178-XLB has been developed to accommodate up to 96 single fusion splices, and 288 mass fusion splices. The closure has two 1" ports and one 1.4" port in the center. Length 14.56" (370 mm) The 2178-XLB splice closure can accommodate four 3M Fiber Optic Splice Trays 2532. The 2532 splice tray can accommodate single fusion, single mechanical or 12-ribbon fiber. 2.0 Kit Contents Visually inspect all components. If any component is missing or appears damaged, do not install. Call customer service at 1-800-426-8688 for a replacement product. 2.1 3M Fiber Optic Splice Closure 2178-XSB/XSB-FR Kit Contents A. M. C. B. E. I. L. F. K. G. J. D. H. N. 3M Multiport Grommet included in certain kits only. A. 1-2178-XSB closure body with bolts B. 2 - Sheath retention inserts C. 1-3M Multiport Grommet (certain kits only) D. 4-1" Washer trees E. 1-1.4" Plug F. 8 - Cable ties (blue) G. 8 - Cable ties (green) H. 2-3M Reclosable Dual Lock Fasteners I. 1 - Roll Scotch Linerless Rubber Splicing Tape 130C J. 1 - Packet of silicone lubricant K. 2-1" Hose clamps L. 1 - Sheath scuff M. 1 - Tray support with strap N. 1 - Tape collar gauge O. 1 - Transition tube-tie-down. Bracket not shown. 78-8135-0094-5-K 3

2.2 3M Fiber Optic Splice Closure 2178-XLB/XLB-FR Kit Contents A. M. C. L. E. N. I. B. K. 3M Multiport Grommet included in certain kits only. H. D. F. J. G. A. 1-2178-XLB closure body with bolts B. 2 - Sheath retention inserts C. 1-3M Multiport Grommet (certain kits only) D. 4-1" Washer trees E. 1-1.4" Plug F. 8 - Cable ties (blue) G. 8 - Cable ties (green) H. 2-3M Reclosable Dual Lock Fasteners I. 1 - Roll Scotch Linerless Rubber Splicing Tape 130C J. 1 - Packet of silicone lubricant K. 2-1" Hose clamps L. 1 - Sheath scuff M. 1 - Tray support with strap N. 1 - Tape collar gauge O. 1 - Transition tube-tie-down. Bracket not shown. 2.3 3M Fiber Optic Splice Closure Adapter 2181-XB/XB-FR Kit Contents A. C. M. M. I. B. O. L. K. E. N. H. J. D. F. G. 3M Multiport Grommet included in certain kits only. A. 1-2181-XB adapter with gasket B. 3 - Sheath retention inserts C. 1-3M Multiport Grommet (certain kits only) D. 4-1" Washer trees E. 1-1.4" Plug F. 8 - Cable ties (blue) G. 8 - Cable ties (green) H. 2-1.4" Washer trees I. 1 - Roll Scotch Linerless Rubber Tape 130-C J. 1 - Packet of silicone lubricant K. 3-1" Hose clamps L. 1 - Sheath scuff M. 10 - Bolts N. 1 - Tape collar gauge O. 2-1" Plugs 4 78-8135-0094-5-K

2.4 Additional materials required: 3M Fiber Optic Splice Tray 2532 To branch splice in the center port, order 3M 1.4" Cable Branch Port Kit, part no. 80-6113-1460-2. For armored sheath cable, use 3M Scotchlok Shield Bond Connector 4460-D/FO. Note: Closure can handle two trays. 3.0 Cable Preparation 3.1 Determine amount of cable needed for storage and splicing. The closure can store 8' (2.4 m) of buffer tube fiber. 3.2 Remove sheath and clean fiber per company practice. 3.3 Scuff 6" (150 mm) of cable sheath, starting at end of sheath. 3.4 Secure the strength members. 3.4.1 If cable has central strength member, assemble strength member clamp onto strain relief bracket as shown in Figure 2. Mark and cut the central strength member at end of strength member clamp. Figure 1 3.4.2 If cable has dual strength members, assemble strength member clamp onto strain relief bracket as shown in Figure 3. Figure 2 Figure 3 78-8135-0094-5-K 5

3.4.3 If securing the strength members is not required, the front half of the sheath retention inserts can be removed as shown in Figure 4. 3.4.4 Slide central strength member under retention lug and tighten bolt to 40 in-lbs ± 5 in-lbs (4.6 N m ± 0.6 N m). 3.4.5 Cut a small length of the unused sheath scuff and place it grit side inward inside of the hose clamp. Figure 4 Note: The cut piece of sheath scuff should wrap at least halfway around the cable sheath, but not completely around the cable. Place cable retention clamp and sheath scuff onto the cable so that hose clamp will be 1" (25 mm) from end of sheath. 3.4.6 Install hose clamp and tighten to 40 in-lbs ± 5 in-lbs (4.6 N m ± 0.6 N m). 3.5 For armored cables (Figure 6), use 3M Scotchlok Shield Bond Connector 4460-D/FO Kit. Figure 5 Figure 6 6 78-8135-0094-5-K

3.6 Place retention clamp into place in the closure and mark location of gasket edges on cable. This will be the area of the tape collar. 3.7 Determine the diameter of the scuffed area of the cable and choose two (2) appropriately sized washers for each cable. Washer inner diameters should be as close to the diameter of the cable as possible. 3.7.1 If diameter of cable is close to either end of the marked washer diameter range, try both sizes and choose the snuggest fit available. 3.7.2 For example, if the cable diameter measures 1.12", try both the 1.0 1.1 and 1.1 1.2 marked washers. Select the washer with the snuggest fit around the cable diameter, allowing the washer to close at the split. 3.8 Place washers onto cable on either side of the area marked for tape collar build up. Washers may be split if necessary to ease installation. Figure 7 3.9 Using the supplied Scotch Linerless Rubber Splicing Tape 130C, build up the collars to the appropriate diameter from approximately 1.5 (40 mm) from sheath opening. Figure 8 Figure 9 78-8135-0094-5-K 7

3.9.1 Collars should be built up to 1.45" diameter for large port and 1.05" diameter for the smaller port. Use the tape collar gauge provided in kit to measure for required diameter. 1.05" end 1.45" end Figure 10 3.10 Thinly coat all surfaces of cable ports and tape collar with silicone lubricant and insert into gasket at the proper port. Insert cable retention clamp into slot at same time and push down until cable is in proper alignment. Note: Ensure that washers are properly seated in the grooves of the case on either side of the gasket. Note: Carefully follow health and safety environmental instructions as given on Material Safety Data Sheet for the silicone lubricant. 3.11 Using two (2) black cable ties, retain cables in ports by placing ties both inside and outside the base. Note: White cable ties are shown for clarity. Figure 11 Figure 12 8 78-8135-0094-5-K

3.12 For ribbon transition to tray applications, secure the transition tube to the bracket mounted in base. 3.13 When tray support and tray are in place, mount the other end of the transition tube to the tray. Figure 13 4.0 Drop Cable Preparation 4.1 Determine how many drop cables will be passing through the 3M Multiport Grommet. Figure 14 4.2 Remove sheath on drops exposing buffer tubes to a length required per company practice. 4.3 Insert drops into multiport grommet first and then insert blank plugs last. Note: A small amount of lubricant provided in kit may be placed on blank plugs and cable to allow for ease of installation into multiport grommet. An additional method to ease installation is to take sheath scuff supplied in closure kits, and slightly sand the leading edge of the drop cable and blank plugs. Figure 15 78-8135-0094-5-K 9

4.4 Grease approximately 2" (50 mm) of cable drop jacket. 4.5 Place a small amount of lubricant on the gasket inside diameter in the area where it seals with the 3M Multiport Grommet. Note: Carefully follow health and safety environmental instructions as given on Material Safety Data Sheet for the silicone lubricant. Figure 16 4.6 Insert drop 1" 2" (25 mm 50 mm) into multiport grommet and then pull back out. 4.7 Insert drop the entire length of multiport grommet. 4.8 Repeat steps 4.3 4.7 for the blank plugs as well. Note: Leave future ports orientated to top of closure for ease of future installations of drop. 5.0 3M Multiport Grommet 6-Port (1.4") Installation 5.1 Break off the tab feature as shown on both cable strain relief brackets. 5.2 Place cable strain relief brackets on either side of the grommet, with three drops on either side as shown. Insert cable strength members into small K-connectors. Figure 17 Figure 18 10 78-8135-0094-5-K

5.3 Secure cable strain relief brackets and the strain relief bracket from the closure to the grommet with the hose clamp as shown. Tighten the hose clamp to 40 in.-lbs. ± 5 in.-lbs. (4.6 N m ± 0.6 N m). Note: Ensure that extruded retention feature of strain relief has sufficient contact with surface of grommet. Figure 19 5.4 Tighten the six K-connector nuts to 40 in.-lbs. ± 5 in.-lbs. (4.6 N m ± 0.6 N m) each. Figure 20 5.5 Place cable strain relief and the 3M Multiport Grommet assembly into closure. 5.6 Place cable ties around multiport grommet assembly inside and out as shown. Note: White cable ties are shown for clarity. 5.7 Follow closure instruction for all other preparation leading up to and including sealing closure. 3M Fiber Optic Splice Closure 2178 XSB 3M Fiber Optic Splice Closure 2178 XLB 78-8135-0094-5-K 11

6.0 Tray Installation and Splicing 6.1 Once cables have been anchored, place tray support in position and tighten two (2) screws. 6.2 Cut two 3M Reclosable Dual Lock Fasteners in half. Remove liner from two pieces of fastener and place on tray support as shown. Mate second two pieces of fastener to the attached pieces. Remove liner from back of top pieces and attach first tray. 7.0 Fiber Management Inside Tray 7.1 Select appropriate splice holder based on type of splicing to be performed Figure 21 7.2 Remove adhesive backing and position splice holders on tray. Note: Positioning of splice holders should be such that a minimum of 1.5" (40 mm) bend radius is maintained for each fiber to be spliced. Note: In a dirty environment an alcohol wipe may be used to clean tray surface for better adhesion. Note: Carefully follow safety, health and environmental information given on product label or the Material Safety Data Sheet for the cleaner. 7.3 Route buffer tube or ribbon to desired tray corner. Note: Do not exceed minimum 1.5" (40 mm) bend radius during routing process. 7.4 Secure loose buffer tube to tray using the supplied cable ties. Figure 22 12 78-8135-0094-5-K

7.5 Place ribbon fiber into 1" 1.5" (25 mm 40 mm) of ribbon retention grommet (cut segments as needed from supplied length) and secure assembly into tray using supplied cable ties. Be sure to use two cable ties per each buffer tube. (A maximum of six ribbons can be loaded into each retention grommet segment.) Note: Do NOT use pliers to tighten cable ties to tray. Cable ties should be hand tightened such that ribbon or buffer tube are immobilized. Over tightening can cause damage to buffer tube or ribbon. Figure 23 7.6 Splice per company practice and place sleeves into splice holders. 8.0 Splice Closure Assembly 8.1 Thinly coat all gasket surfaces with a light application of silicone lubricant to aid in gasket sealing. Note: Carefully follow health and safety environmental instructions as given on Material Safety Data Sheet for the silicone lubricant. 8.2 Place cover on base and hand start bolts 1, 5, 7, and 3 in that order first. All others can be started in any order. Using tightening sequence, torque all bolts to 240 in-lbs. Torque -FR Closures to 50 in-lbs. TORQUING SEQUENCE 8.3 Closure should be flash tested by pressurizing closure to a maximum of 5 PSI. Check for leaks and then release air pressure. 8.4 On future opening and closing of closure, if leaks are detected, torque bolts or re-tape cable ports as needed. 78-8135-0094-5-K 13

9.0 Opening Splice Closure 9.1 To re-enter splice closure, open bolt positions 5, 7, 1 and 3 in seqence. All other bolt positions can be opened randomly. 10.0 Closure Accessories 3M Cable Branch Port Kit 2178-XSB-1.4B 3M Wall Mount Bracket 2198 3M Adjustable Aerial Hanger Bracket Kit 2184 3M Fiber Splice Organizer Tray 2532 3M 4-Port Grommet 4PGA 14 78-8135-0094-5-K

78-8135-0094-5-K 15

3M, Scotchlok and Dual Lock are trademarks of 3M Company. Scotch is a registered trademark of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Communication Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 1-800-426-8688 www.3mtelecommunications.com Please Recycle. Printed in USA. 3M 2010. All Rights Reserved. 78-8135-0094-5-K