Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.

Similar documents
I Ex-protected connectors exlink I

Process transmitter RMA422

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

PMG. Vibration Energy Harvesters

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Capacitance Level Measurement Electronic insert FEC 12

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Inductive sensor NI3-EG08K-Y1-H1341

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Model JDF Field Indicator

Pendant Light Fitting IEC Series 6470/2

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor NI10-M18-Y1X-H1141

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

ATEX-manual for units

Eddy Current Probe System

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

TFR5 Room or outdoor temperature sensor. CombiTemp TM

IEPE Premium Accelerometer, Top Connector

IEPE Premium Accelerometer, Side Connector

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

7 Lighting Technology

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

8 Installation Equipment

RMA42. Technical Information

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

ACT20X Series for hazardous area applications Section A

I/A Series Hardware Fieldbus Communications Module, FCM10Ef

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

PROPORTIONAL VALVES Sentronic plus

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

BNC-2110 DESKTOP AND DIN RAIL-MOUNTABLE BNC ADAPTER

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

MODEL HS35 DRAWWORKS OPTICAL ENCODER

Pressure transmitter For applications in hazardous areas Model IS-3

RSCC. Load cells. Special features. Data sheet

EXPlora. Introduction

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DMP 331i / DMP 333i LMP 331 i

3500/42M Proximitor*/Seismic Monitor

Process Transmitter RMA 422

TFRN Industrial RTD temperature sensor. CombiTemp TM

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Circuit-Breakers for Motor Protection Series 8523/8

Quality products from a single source

TFRN Industrial RTD temperature sensor. CombiTemp TM

3 Cleaning. 4 Technical data

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

BNC-2120 INSTALLATION GUIDE. Connector Accessory for Multifunction DAQ Devices

Capacitance Limit Detection nivotester FTC 420/421/422

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

FIELD MOUNTED RATE TOTALISER MODEL 202D

Operating instructions

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

CATEGORY 6 CABLING SOLUTIONS

Highlights: Cables & Adaptors. Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Connector Adaptors

Speed sensor MiniCoder GEL 2471

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

TFRH Hygienic RTD temperature sensor. CombiTemp TM

User manual Version Ex Remote station XGA 15" family type 17-71KB-45../... Ex Remote station SXGA 18" family type 17-71KB-55../...

Rosemount 1151 Smart Pressure Transmitter

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Inductive sensor With analog output BI15-M30-LI-EXI

I/A Series Hardware Fiber Optic LAN Converter

Level Measurement silometer FMC 420, FMC 423

4 Wiring Brochure Wiring and installation of specific control

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

ExCam XPT Q6055. User Manual

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

General Specifications

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Flow Measurement SITRANS F M

Transcription:

Thermoacoustics Technical Brochure Product Line for Combustion Dynamics on Gas Turbine

Modular Measuring Chains. This technical brochure provides an overview how the various system components of the Kistler thermoacoustics product line can be combined to form complete measuring chains for typical application scenarios. Various measuring chain configurations for operation in non explosive environments (Non-Ex) and in potentially explosive atmospheres ('Ex-nA' non sparking and 'Ex-ia' intrinsically safe) are explained in detail. Non-Ex p Type 6021A..., 6023A..., 6025A... Softline Cable Differrential Charge Amplifier Type 5181A... DA System Non-Sparking (Ex-nA) Hazardous area (ATEX Zone 2) Non-hazardous area Type 6021AE..., 6023AE..., 6025AE... Softline Cable Differential Charge Amplifier 5185A... DA System Intrinsically Safe (Ex-ia) Hazardous area Non-hazardous area ATEX Zone 0, 1 or 2 ATEX Zone 1 or 2 Type 6021AE..., 6023AE..., 6025AE... Softline Cable Differential Charge Amplifier 5183A... Ex-barrier DA System 2

High-Temperature Pressure s. Kistler's durable sensors based on proprietary PiezoStar crystal material have been developed specifically for high-temperature environments of up to 700 C. 36,7 5,1 9 Type 6021 + 11 - - 0,01 0,03 9,5 - - 0,01 0,03 9 GND 53,6 40,7 5,1 Key Features 19,05 12 - - 0,01 0,03 49,7 24,8 5 12,3 Type 6023 Operating temperature range 55... 650 C / 67... 1 200 F Integrated mineral insulated hardline cable Differential signal output, 2-wire system Acceleration compensated High natural frequency >50 khz Internally case isolated 19 12,7 - - 0,01 0,03 Types 6021A..., 6023A... and 6025 A... 13 Type 6025 Available Configurations The Kistler sensor platform is highly flexible. s are available in different cable lengths and with several cable terminations. Options Length of hardline cable Various cable terminations Ex-Certification (Ex-nA, Ex-ia) IECEx ä1258 IECEx SEV XXXXX Ex na IIC T6 to T710 Gc Ex ia IIC T6 to T710 Gc SEV XX ATEX XXXX II 3G Ex na IIC T6 to T710 Ga II 1/2G Ex ia IIC T6 to T710 Ga 6021A... 65 pc/bar 9,5 Type 6021 Lemo PCA.0S.302 602_A_B0A... 6023A... 95 pc/bar 12 Type 6023 7/16"-27 UNS-2A 602_A_B0B... 6025A... 105 pc/bar 12,7 Type 6025 3

Two-Wire Softline Cables. Kistler's two-wire softline cables form an integral part of the differential measuring system. They are responsible for disturbance-free transmission of low level charge signals over distances up to 50 meters even in environments with electromagnetic interferences. Key Features Operating temperature range 55... 200 C / 67... 392 F 2-core twisted pair, indiv. braided shield Steel overbraid Locking connectors + + SGND Options Standard cable length: 5, 10 and 20 m Different connector options GND GND Available Cable Configurations Compatibility L = 0,5...... 50 50 m m Compatibility Type 602xAxA... A2 9,9 LEMO FFA.0S.302 FFA.1E.304 13 A4 AI Casing Type 518xAA 46,3 5,3 41,3 Type Z20167 B2 12 Fischer S 103 A051 45,3 FGG.0B.302 42,6 9,5 A2 e.g. Bently Electronics Type 602xAxB... C2 13 7/16"-27 UNS-2A 31,8 10 35,3 40 2 pole open leads plus drain wire A3 DIN Rail Casing Type 517xAB Cable gland for AI Casing Type 518xAA 4

Differential Charge Amplifiers. Kistler's differential charge amplifier family offers a wide range of signal conversion possibilities and is available in non-ex, Ex-ia and Ex-nA versions. Type Version Ex Protection Enclosure 5181A... Non-Ex version 5183A... Ex-ia II 3G Ex na II T5 Ga II 3G Ex na IIC T5 Ga X 5185A... Ex-nA II 3G Ex na IIC T5 Gc II 3G Ex na IIC T5 Gc X Each Type is available in two enclosure versions Aluminum die cast enclosure Ideal for low channel count Installation in Ex-zone without additional enclosure Connectors or cable glands Aluminum die-cast Plastic DIN-Rail Aluminum die-cast Plastic DIN-Rail Signal Output and Power Supply Option only for Type 5181A available Types 5181AA... / 5183AA... / 5185AA... Plastic DIN-Rail enclosure Ideal for high channel count Installation in Ex-zone requires additional "Ex Box" Screw terminal connections 114,5 99 Types 5181AB... / 5183AB... / 5185AB... 22,5 Options Sensitivity: Default U-Out version: 10 mv/pc I-Out version: 6 μa/pc Custom SE voltage Out * ±10 V: 10 400 mv/pc SE voltage Out 5 ±5 V: 5... 200 mv/pc Diff. Out ±10 V: 10 400 mv/pc I-Out 14 ±6 ma: 6 240 μa/pc * Extended ranges are available on request Signal output options: Voltage SE (±10 V; 5 ±5 V) or Differential (±10 V) Current (14 ±6 ma); 3-wire or 2-wire current loop Programmable low and high pass filter Default (f HP 0,5 Hz / f LP 10 khz) 5

Measuring Chain Configurations. The following examples show some of the most common measuring chain configurations for non-ex and for Ex-protection Ex-nA and Ex-ia. HT-Pressure s Softline Cable Differential Charge Amplifier Typ 5181AA... Non-Ex Installation Type 6021A-... Typ 6023A-... Typ 6025A-... Softline cable Typ 5181AB... Typ 5185AA... Ex-nA (Zone 2) Installation Type 6021AE... Typ 6023AE... Typ 6025AE... Softline cable Typ 5185AB... HT-Pressure s Softline Cable Differential Charge Amplifier Ex-barrier Typ 5183AA... Ex-ia (Zone 0, 1, 2) Installation Type 6021AE... Typ 6023AE... Typ 6025AE... Softline cable Typ 5183AB... 3rd party 6

Special Use Cases. The following use cases show how Kistler measuring chains can be configured to meet specific requirements. Use Case 1: Ex-Applications (-na, -ia) 1-wire PE Differential Charge Amplifier For applications in hazardous environment (-na, -ia) standard 1-wire PE Ex-certified pressure sensors can be operated with the differential charge amplifier Type 5183 or 5185. Hazardous area (ATEX Zone 2) Non-hazardous area p 1-Wire PE Softline Cable Differential Charge Amplifier Type 5185A... Advantage: Ex-applications can be covered available on request DA System Disadvantage: non differential signal Use Case 2: Differential Single Ended Operation of differential output sensor with a conventional non-differential charge amplifier (typically in a laboratory environment). p Type 6021A..., 6023A..., 6025A... Softline Cable Type 1654A... Non-differential Charge Amplifier DA System Advantage: use of non-differential charge amplifiers Disadvantage: non differential signal 1-wire Ground Isolated Connecting Cable, Type 1654A... For operation with non-differential charge amplifiers. LEMO FFA.0S.302 1 pole connector BNC pos. 7/16"-27 UNS-2A 7

960-201e-01.16 2016, Kistler Group Kistler Group Eulachstrasse 22 8408 Winterthur Switzerland Tel. +41 52 224 11 11 Kistler Group includes the Kistler Holding AG and all its subsidiaries in Europe, Asia, Americas and Australia. Find your local contact at