TASTEPROBE Type DTP-1. Pre-amplifier for recording from contact chemosensilla INSTRUCTIONS

Similar documents
Operating Instructions

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

STIMULUS CONTROLLER, Type CS-55 INSTRUCTIONS

Metal Electrode Meter

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System

EGM Einthoven Goldberger Module Type 701

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Using an oscilloscope - The Hameg 203-6

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

SC26 Magnetic Field Cancelling System

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

LAUREL ELECTRONICS, INC.

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

medlab One Channel ECG OEM Module EG 01000

Features/Specifications

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

Beginners How to Test DSO138mini

3B SCIENTIFIC PHYSICS

Activity P32: Variation of Light Intensity (Light Sensor)

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I

Cryoelectronics. MS-FLL User s Manual. Mr. SQUID Flux-Locked Loop. STAR Cryoelectronics 25 Bisbee Court, Suite A Santa Fe, NM U. S. A.

ML785 PowerLab/8SP ADInstruments Data Acquisition Systems

4.9 BEAM BLANKING AND PULSING OPTIONS

Introduction to the oscilloscope and digital data acquisition

Operating instructions Electronic preset counter Type series 717

Video Streamer Modifications

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

ECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS

Portable in vivo Recording System

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Hardware & software Specifications

DIGITAL SPEAKER MANAGEMENT UK


New Generation of MEA-Systems: MEA2100-System

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Digital Storage Oscilloscopes 2550 Series

2 MHz Lock-In Amplifier

Fluke 190-Series II Firmware Upgrade V11.44

P-2 Installing the monitor (continued) Carry out as necessary

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

UHF REMOTE RECEIVER INSTALLATION & PROGRAMMING

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

3G/HD/SD dual channel audio embedder/de-embedder

SignalTap Plus System Analyzer

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

Operating Instructions

Electrical connection

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 65 MSPS DUAL ADC

Noise Detector ND-1 Operating Manual

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

imso-104 Manual Revised July 19, 2012

MICROMASTER Encoder Module

Micro-DCI 53ML5100 Manual Loader

ASK THE EXPERTS: Procedure for Verifying Magnetic Pickup Signal Integrity Using a Windrock Portable Analyzer

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Absolute Encoders Multiturn

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

EVD-L04/100A1-960, EVD-L08/200A1-960 and. EVD-L16/400A1-960 DVRs. Quick Operation Guide

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

LM/TM-30xx, 31xx Series LCD Monitor User s Manual Rev. A0

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

C-net WIND. User s Guide

Interface Connectors for Miniature, Portable Terminal Devices

013-RD

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Sensor technologies Proximity sensors Series ST4. Brochure

"shell" digital storage oscilloscope (Beta)

VNS2200 Amplifier & Controller Installation Guide

imso-104 Manual Revised August 5, 2011

AI-1664LAX-USB. Features. 100KSPS 16-bit Analog Input Unit for USB AI-1664LAX-USB 1. Ver.1.01

Lt DELTA USA, Inc

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

VFR 1 Recorder USER MANUAL

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

REGO Start&Go USER MANUAL

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Single Axis Position Controller

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Introduction: Overview. EECE 2510 Circuits and Signals: Biomedical Applications. ECG Circuit 2 Analog Filtering and A/D Conversion

University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

G.R.A.S. Sound & Vibration

Transcription:

TASTEPROBE Type DTP-1 Pre-amplifier for recording from contact chemosensilla INSTRUCTIONS

SYNTECH 2002 Hilversum, The Netherlands Reproduction of text and/or drawings is permitted for personal use. The use of reproductions in publications is only allowed if correct reference is made to SYNTECH

TastePROBE Type DTP-1 with high input impedance headstage and electrode holder

READY RUNNING CLIP INPUT HEADSTAGE (GAIN 1 x) CLIP TOTAL SYSTEM GAIN 10 x MENU DOWN (RUN) UP (MODE) ENTER SYNTECH TastePROBE DTP-02 FRONT PANEL IDAC SIGNAL / POWER INTERFACE TastePROBE DTP-02 REAR PANEL 12 V DC EXT. POWER SUPPLY SIGNAL OUT TRIGGER OUT TRIGGER ENABLE + PEDAL SWITCH Fig. 1 TASTEPROBE FRONT and REAR PANEL

1 INTRODUCTION The SYNTECH Tasteprobe, Type DTP-1, is a further development of the prototype of the special amplifier described by Marion-Poll and Van der Pers (1996) that permits reliable DC recordings from insect taste receptors using the Hodgson (1955) technique. The present model can operate in DC or in AC mode. In DC mode the complete signal, slow (DC) and fast (AC) fluctuations are recorded and amplified. In AC mode the slow (DC) fluctuations are out-filtered and only the fast (AC) components of the signal (like Spikes) are amplified. In both recording modes the DC initial offset at the onset of the recording (before contact is made between the recording electrode and the preparation) is cancelled automatically. DESCRIPTION (The numbers refer to the encircled numbers in Fig. 1) FRONT PANEL 1 Input receptacle for the headstage (Probe) containing the high input impedance pre-amplifier. The pipette electrode holder is mounted directly on the headstage. 2 Display showing the settings and the modes of operation 3 LED indicating the 'ready' status of the device 4 LED showing the 'running' status 5 LED indicating a positive over-voltage at the input 6 LED indicating a negative over-voltage at the input 7 MENU button 8 Selection button ; also: ENABLE button 9 Selection button ; also: PASS-THROUGH operation 10 Enter button to leave the menu and to return to ready REAR PANEL 11 Receptacle to connect the Tasteprobe with a Syntech IDAC interface 12 12 V Power input (not needed with Syntech IDAC interface) 13 Signal output (10 x amplified) 14 Trigger signal output 15 Enable switch (pedal switch) input

INTELLIGENT DATA ACQUISITION CONTROLLER USB ANALOG DIGITAL 1 2 3 4 POWER EXTENSION READY IDAC SIGNAL / POWER INTERFACE Syntech NL TasteProbe V2.0 RUNNING CLIP TastePROBE DTP-02 INPUT HEADSTAGE (GAIN 1 x) CLIP 12 V DC EXT. POWER SUPPLY SIGNAL OUT TRIGGER OUT TRIGGER ENABLE TOTAL SYSTEM GAIN 10 x MENU DOWN (RUN) UP (MODE) ENTER PEDAL SWITCH SYNTECH TastePROBE DTP-02 FRONT REAR Electrode holder with pipette electrode Probe GROUND of SET UP PEDAL SWITCH Fig. 2 CONNECTIONS FOR USE WITH SYNTECH USB-IDAC

2 OPERATION USING THE INITIAL SETTINGS The instrument can be operated without changing the settings as entered by the manufacturer. These setting are suitable for a first test and to become familiar with the system. After the device has been connected the settings can be checked by pushing the MODE button repeatedly; push ENTER to return to the READY state. CONNECTIONS to Syntech USB-IDAC (Fig. 2) 1 Connect the headstage (probe) 2 Connect the pedal switch 3 Make the connection between the IDAC interface using the special cable supplied (see figure). Connect to the Analog 1 input of the USB- IDAC (Fig. 2). (Power is supplied by the USB-IDAC through this cable). 4 Make the connection for the Trigger : connect the Trigger out at the rear of the Tasteprobe to the Digital 1 input of the USB-IDAC. 5 Configure the Autospike program to record at least Channel 1, enter the ext. ampl. factor to 10; set the high Filter at 3000 Hz, the low Filter to 100 Hz, and set the Digital channel 1 to trigger at the highest sample rate (Fig. 7). Connect an Audio monitor amplifier to the Audio output of the USB- IDAC, and enable the Audio output for Channel 1 (Fig. 7). CONNECTIONS to any DATA ACQUISTION SYSTEM (fig. 3) 1 Connect the headstage (probe) 2 Connect the pedal switch 3 Connect the SIGNAL OUT receptacle at the rear of the Tasteprobe to an analog signal input of a suitable DATA ACQUISITION system. 4 Make the connection for the Trigger : connect to the Trigger out at the rear of the Tasteprobe to the trigger input of the DATA ACQUISITION system 5 Provide the 12V power at the rear of the Tasteprobe using a suitable power supply (12 V DC, regulated ; min. 200 ma) 6 Configure the Data Acquisition software for recording of the analog signal, and select a NEGATIVE trigger input. (If only a Positive trigger input is available, change the Trigger setting in the Tasteprobe menu to Positive (Fig. 6).

DATA ACQUISITION SYSTEM 12 V POWER SUPPLY ANALOG SIGNAL INPUT TRIGGER INPUT 12 V DC READY IDAC SIGNAL / POWER INTERFACE Syntech NL TasteProbe V2.0 RUNNING CLIP TastePROBE DTP-02 INPUT HEADSTAGE (GAIN 1 x) TOTAL SYSTEM GAIN 10 x SYNTECH TastePROBE DTP-02 MENU DOWN (RUN) UP (MODE) ENTER CLIP 12 V DC EXT. POWER SUPPLY + SIGNAL OUT TRIGGER OUT TRIGGER ENABLE PEDAL SWITCH FRONT REAR Electrode holder with pipette electrode Probe GROUND of SET UP PEDAL SWITCH Fig. 3 CONNECTIONS FOR USE WITH DATA ACQUISITION SYSTEM

3 INPUT CONFIGURATION (Fig. 4) 7 Prepare the pipette electrode (Fig. 5). 8 Select and prepare a suitable insect preparation. Connect the preparation to the central (common) GROUND of the recording set up. 9 Connect the shaft of the headstage also to the central GROUND 10 Connect the Faraday cage and other metal devices to the central GROUND PASS-THROUGH RECORDING 11 Start the Syntech Auto spike program. Check the Recording properties and the Filter settings (Fig. 7) or start another suitable Data Acquisition program. 12 Press the ENTER button of the Tasteprobe. The READY Led should go ON. 13 Check the baseline on the display of the recording system. Adjust the vertical scale (sensitivity) of the recording display between 1 mv - 10 mv. 14 Press the UP (MODE) button: The Tasteprobe is now in PASS-THROUGH mode. In this mode the system operates as a normal 10x amplifier. 15 Establish contact with the preparation. Record the resulting signal trace. If the data acquisition system and software settings all are properly adjusted the signal from the preparation should be visible on the signal display. The characteristics of the recorded signal should be the same as expected from a normal 10x amplifier with a high-pass filter of 100 Hz. Offset voltages are NOT compensated in the PASS-THROUGH mode! (Signals from taste sensilla may NOT come through!)

To USB port USB CABLE USB-IDAC INTERFACE INTELLIGENT DATA ACQUISITION CONTROLLER USB ANALOG DIGITAL 1 2 3 4 POWER EXTENSION READY IDAC SIGNAL / POWER INTERFACE INPUT HEADSTAGE (GAI N 1 x) Syntech NL TasteProbe V2.0 RUNNING CLIP CLIP 12 V DC EXT. POWER SUPPLY TastePROBE DTP-02 SIGNAL TRIGGER TRIGGER OUT OUT ENABLE TO TAL SYSTEM GAIN 10 x MENU DOWN (RUN) UP (MODE) ENTER PEDAL SWITCH SYNTECH TastePROBE DTP-02 FRONT REAR Faraday cage Micro Manipulator Probe Preparation GROUND of SET UP Pedal switch Fig. 4 GENERAL RECORDING ARRANGEMENT

stainless steel body pipette guide wire guide CROSS SECTION of ELECTRODE HOLDER insulation SILVER WIRE 0.3-0.5 mm make tiny bend at end of wire insert wire into holder screw holder onto probe GLASS PIPETTE ELECTRODE diam. 1.5 mm insert pipette into electrode holder Do NOT connect electrode holder to ground! Fig. 5 Electrode Preparation

DC 100 Hz 2V, 1V, GND, +1V, +2V, Open Continue, 1 100 Sec OFF ON 0 1 30 Sec 0.5 100 ms Negative Positive 1 12 ON OFF 0 60 ON OFF Fig. 6 MENU OPTIONS and SETTINGS

Recording Properties / Settings * Enable Channel 1 * Select Sample rate at 11904 or higher * Set External Amplification to 10 * Set Digital Sample rate at 1904 (the maximum) Recording Properties / Digital I/O * Enable Channel 1 * Set Trigger to input 1 * Set A/B Channel to None Filter Settings * Set High cutoff at 3kHz * Set Low cutoff at 100Hz * Enable Audio out Fig. 7 AutoSpike RECORDING and FILTER SETTINGS

Filter Settings * Set High cutoff at 3kHz * Set Low cutoff at DC * Enable Audio out Use SLIDER for coarse adjustment UP - DOWN buttons for fine adjustment Fig. 8 AutoSpike FILTER SETTINGS and OFFSET CONTROL for DC RECORDING

4 NORMAL (Offset-compensated) RECORDING 16 Disconnect the pipette electrode from the preparation 17 Press the ENTER button (The READY Led goes ON) if needed. This is only necessary if the system is NOT already in the READY state. 18 Press the PEDAL SWITCH (or the DOWN (RUN) button). The display now shows: WAITING FOR CONTACT... and the RUNNING Led is blinking It is possible that the RECORDING is triggered, indicated on the display and by a BEEP. If this is the case, the TRIGGER threshold must be increased. Press the MENU button several times until the Trig. Threshold appears; use the UP button to increase the value (max. is 12;Fig. 6) 19 Make contact with the preparation. A BEEP should be audible, and the display shows RECORDING, indicating that the offset has been compensated and the recording is started. During recording the RUNNING Led is ON. The display counts down the recording time (in seconds) and the end of the recording time is indicated by another BEEP. If NO Beep is produced, and the system does NOT go into the Recording state, the TRIGGER threshold might be too high; Decrease the Trig. Threshold in the appropriate MENU box (Fig. 6). The system returns to the READY state automatically. 20 Check the recorded signal on the display of the signal acquisition system used. Adjust scale and timing values if necessary 21 To make another recording disconnect the electrode from the preparation, and press the PEDAL switch (or the DOWN (RUN) button) just before making contact again.

5 DC RECORDING For DC recording it is necessary to set all signal conditioning circuits in DC mode and to adjust the output baseline level exactly to zero. The signal may contain large DC fluctuations; therefore, the signal recording interface (Syntech IDAC or any other acquisition system) output scale should be adjusted accordingly (10-20 mv). If full DC recording results in too large fluctuations the signal can be filtered (High-Pass 0.1 Hz - 10 Hz; see Fig. 6) until the signal fits in the recording amplitude window. The DC component of the signal is stronger suppressed at higher filter values. For DC recording, the following settings and adjustments must be made: * In the Tasteprobe: High-Pass : DC (Fig. 6) * In the IDAC Filter settings: Low cutoff: DC (Fig. 8) The filter settings in any other acquisition system must be set to DC * Set the signal display scale to 10 or 1 mv and bring the signal trace to the zero level (Fig. 8) Operation of the Tasteprobe in DC mode is otherwise the same as for AC recording ( steps 16-21) ZEROING TIME In DC recording the signals may show large irregular fluctuations at the onset, which are a result of instabilities during the initial contact with the sensillum. These large fluctuations may be suppressed by increasing the ZEROING TIME. However, any actionpotentials generated during the zeroing time will not be recorded. Therefore, the zeroing time should be as short as possible. PROBE OFFSET and TRIGGER THRESHOLD Normally the Probe Offset (Fig. 6) is kept at ground (= zero) potential by a shunt resistor of 1 Gohm inside the headstage. This offset voltage can be adjusted from -2 to +2 V (Fig. 6) to test the sensitivity of the preparation to input offset transients or the improve the activation of the trigger. The input may also be left in the open state. The trigger threshold is adjustable in 12 steps, and should be adjusted such that no 'false triggering' occurs before the pipette has been brought in contact with the preparation, but that the trigger does respond immediately after contact has been made. The trigger can only be activated in the WAITING FOR CONTACT... state.

6 AUTOMATIC INITIALISATION (AUTO RESTART) It is not always necessary to use the pedal switch to enable the WAITING FOR CONTACT... state. If the recording situation is free of interference and there is no risk for activation of the trigger before contact has been made, or if repeated contact need to be made, the Tasteprobe can be set to Auto Restart by changing the appropriate setting (Fig. 6) In the Auto Restart mode the system automatically returns to the WAITING FOR CONTACT... after an adjustable delay. The delay can be entered in the Restart Delay box (Fig. 6). During the restart delay time the trigger cannot be activated, and the count-down time is indicated by a BEEP every second. A few seconds before the end of the restart delay time the beep rate is increased. The restart delay time allows replacement of the pipette without the risk of 'false triggering'. For repeated stimulations the delay time can be set to zero. TRIGGER OUTPUT The trigger output is a TTL signal, which changes either from Low (0) to High (5V) during the recording time if set to Positive, or from High (5V) to Low (0) if set to Negative (Fig. 6). The Syntech USB-IDAC responds by default to a Negative trigger; however, this can be inverted in the Digital I/O properties. Make sure that for any other signal acquisition system the trigger polarity is set according to the trigger requirements of that system. REFERENCES Hodgson, E.S., J.Y. Lettvin & K.D. Roeder, 1955. Physiology of a primary chemoreceptor unit. Science 122: 417-418 Marion-Poll, F. & J. van der Pers, 1996. Un-filtered recordings from insect taste sensilla. Entomologia Experimentalis et Applicata 80: 113-11 January 2003

Tel: +31 35 6219760 Fax: +31 35 6218377 Site: www.syntech.nl E-mail: info@ syntech.nl (syntech@knoware.nl) P.O. box 1547 NL-1200 BM Hilversum, The Netherlands