Automated Local Loop Test System

Similar documents
935AT Communications Test Set Specifications

1.2 General Description

950RTS Remote Test System

Noise Detector ND-1 Operating Manual

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

OPERATOR S MANUAL MICRO SEVEN, INC MODEL LS15-C1 TELEPHONE LINE SIMULATOR

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

Natural-sounding telephone audio... Hybrids

MULTIBAND 1/3 RACK-MOUNTED

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

R-1580A Microwave Downconverter. Product Brochure

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

APPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone

1/3 RACK-MOUNTED BLOCK CONVERTERS

2 MHz Lock-In Amplifier

High Performance Outdoor Test Translators

LT-82 Stationary IR Transmitter

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

DVO700 P FIBRE OPTIC TRANSMITTER

Modular DAA with 2/4 Wire Convertor. XE0002D Block Diagram

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

SAL Series Wireless Clock (V1)

Introduction This application note describes the XTREME-1000E 8VSB Digital Exciter and its applications.

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

Analog HD video over fiber converters for smart HD CCTV

PAM-1840 Preamplifier Operation Manual

LAUREL ELECTRONICS, INC.

TONE COMMANDER SYSTEMS, INC l'oth Ave. N.E., Redmond, WA 980'2, U.s.A Telephone: (206) , Telex:

JD725A Cable and Antenna Analyzer - Dual Port

Telephony Training Systems

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

SIGNALCRAFTERS MODEL 5493 DTMF MODEM

bel canto SEP2 Single Ended Triode Tube Preamplifier User's Guide and Operating Information

OPTICAL POWER METER WITH SMART DETECTOR HEAD

MODEL 5493A DTMF MODEM

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

Synthesized Clock Generator

Rack mounted telephone- and leased line modem for industrial applications

Microwave Counter, Power Meter and DVM in One Portable Package

CATV & DOCSIS3.0 Meter / Analyzer. Purchase from:

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

High-Value 100 Series (Outdoor)

Technical Description

ODW-621. RS-232 Point-to-point applications

I N S T R U C T I O N D A T A

Telephony Training Systems

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

TELSYS Cable Mapping System

OWNERS MANUAL LUNATEC V3 MICROPHONE PREAMPLIFIER AND A/D CONVERTER

MS2540 Current Loop Receiver with RS485 Communication

FIM-108 MATRIX FIBER INTERFACE INSTRUCTION MANUAL

TC3301. User's Manual

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

ECT5484. Fiber Optic Digital Video, Audio & Data Multiplexer/Demultiplexer. Single Fiber Operation. Specifications

Instruction Manual Model BlockUpconverter

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

TCM420 Digital Cable Modem

Multiple Band Outdoor Block Up- and Downconverters

Computer - Digital Output - Modem - Analog - RJ 11 Output Jack

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

2x2 HDMI Matrix Switch - 4K with Fast Switching and Auto-Sensing

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

SYNTHESIZED COMMUNICATION CONVERTERS

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

USER MANUAL. Blackburst, Sync, Audio Tone Generator. For Models BSG-50, RM-50/BSG, SR-50/BSG. Doc Rev. F (C) Copyright 2014

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SCALE & WEIGHT DISPLAYS

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

1900/25 Vibration Monitor

SingMai Electronics SM06. Advanced Composite Video Interface: HD-SDI to acvi converter module. User Manual. Revision 0.

innovative technology to keep you a step ahead 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

2-Port HDMI Automatic Video Switch - 4K with Fast Switching

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

GFT Channel Slave Generator

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

UFX-EbNo Series Precision Generators


Master Time Clock MTC Users Manual

Advanced Test Equipment Rentals ATEC (2832)

USB-TG124A Tracking Generator User Manual

Model FS-4608R. Features. Overview

clipping; yellow LED lights when limiting action occurs. Input Section Features

Model GS Port Node 1 GHz with 65/86 MHz split

263 Series LED Bargraph Indicator and Controllers

MultiMode FOMs -ST and -SMA

HD-3500 Series. HD Video, Audio, Data & Tally/GPIO Channels FEATURES

Advanced Test Equipment Rentals ATEC (2832)

DA E: Series of Narrowband or Wideband Distribution Amplifiers

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

Transcription:

INSTRUMENTS Automated Local Loop Test System Comprehensive Local Loop Testing for Voice, Data, Fax and Internet Services Two-way Testing of Copper, Wireless, and Hybrid-Fiber Coax Local Loops A whole new concept in Local Loop Testing. The 923LTS Hand-held unit works in conjunction with the Sage Instruments 356E Plus Central Office Responder to form the fastest and most comprehensive Local Loop Test System in the industry. A single technician can profile a Local Loop in less than 1 minute (additional time required for a 2-way Impulse Noise Test). Using the 23-Tone testing concept as defined in IEEE Standard 743-1995, the system quickly profiles the transmission characteristics of the local loop. Measurements are compared to a user-defined template and the technician receives a PASS or FAIL indication at the subscriber's site. In addition, the system allows you to enter the circuit number, work order number and the technician's identification. The Callback option measures ringing voltage, verifies that the switch translations have been programmed for the correct telephone number and confirms that the station under test is capable of receiving a call. The unit has a programmable phone list for storing frequently called test numbers and also features an optional built-in Butt Set. The unit is capable of storing the last 10 tests. All data is time/date stamped and stored for easy retrieval. An RS-232 port is provided for printing. Comprehensive Measurements The 923LTS is designed to be connected to the customer network interface (CUST-NI) and automatically performs or measures the following: Loop Voltage Loop Current Call Setup Time Verifies Number Translation (requires callback option) Ringing Voltage (requires callback option) Dial Tone Delay 23-Tone to Measurements: Attenuation Distortion @ 23 Frequencies 2-Wire Group Delay @ 22 Frequencies Signal-to-Noise Ratio Signal-to-Total Distortion 2nd & 3rd Order Intermodulation Distortion

Comprehensive Measurements, Continued 3-Tone Slope C-Message Noise (Psophometric Noise - International) C-Notch Noise (P-Notch Noise - International) Noise-to-Ground Absolute Delay 2-Wire Echo Return Loss (ERL, SRH, SRL) Hits: 3-Level Impulse Noise, Timed Phase Hits Gain Hits Dropouts Jitter: Phase Jitter (hi and low) Amplitude Jitter (hi and low) Quick, Easy-to-Use, and Comprehensive. PASS/FAIL indications take the mystery out of interpreting results. Main Menu 1:<Test> 2:Setup 3:View Results Test Select 1:Copper Install 2:Wireless Install 3:HFC Install From the Main Menu, Select 1: <Test> The unit advances to the Test Select Menu. In this menu, select the test you wish to perform, such as 1: <Copper Install>. This will tell the 356E Plus to use the test suite and measurement template associated with this type of service. Phone # Under Test 4085551212 The unit will automatically advances to the Phone # Under Test screen. Here you enter the number for the circuit that you are testing. Press NEXT to advance to the next entry screen. Enter Your ID John 226 Enter your Name or Company Identification and press NEXT. Numeric <Alpha> Enter Order # 12369AY Enter the Work or Service Order Number and press NEXT. Numeric <Alpha> Responder # 1 #:761 4927 Name: WTVL <Tone> Pulse Manually enter a Responder Test Number or select one from the phone list. Press NEXT and the number will be dialed. All Tests Passed The 923LTS will automatically make 2-way tests on the selected circuit. The 923LTS will display All Tests PASSED or FAILED. At this point, press NEXT to view the individual results or start another test. What could be easier?

356E Plus Central Office Unit Central Office Responder The 356E Plus is a stand-alone responder designed to be rack mounted in the Central Office. The unit is connected to a 2-wire or 4-wire analog test number appearance in the central office. The 356E Plus automatically emulates a 105, 105E, 107 or 23-Tone responder as required. Working in conjunction with the 923LTS Hand-held Unit, the 356E Plus will emulate a 23-Tone responder. In this mode, it is sensitive to the same impairments that affect high speed modem traffic. To minimize any communications problems, a very robust protocol is used to communicate back and forth between the 923LTS and the 356E Plus. This protocol is used to pass status and commands and to transport test results from one unit to another. The 356E Plus is also capable of downloading new test templates to the 923LTS. The unit has an RS-232 port for local printing or remote access. The 356E Plus is the "brain" behind the Sage Instruments Automated Local Loop Test System. It stores all the test templates and determines which tests should be initiated. It then compares all test results to the individual templates. It generates a Pass/Fail indication and sends it to the 923LTS. The 356E Plus has a real-time clock that time-date stamps all results. It stores over 100 individual records, including the circuit number, order number, technician's ID number and all individual test measurements. Each time a test suite is completed, the 356E Plus passes the results of the tests to the 923LTS. The 923LTS maintains in its memory results of the last 10 test suites run. A Wide Range of Applications In addition to working with the 923LTS in the Sage Automated Local Loop Test System, the 356E Plus can be used in a variety of other applications. The 356E Plus can be used in conjunction with the 923LTS, the Sage Instruments 930A Communications Test Set, or the 950RTS Remote Test System to address a wide variety of applications in the Central Office, PABX and private network environments. Uses include: provisioning, quality assurance and preventative maintenance of voice, data, fax and special services. The 356E Plus can be placed at Internet ISPs to conduct special studies on Internet modem performance.

Test System Controller (TSC) This TSC software package resides on a Personal Computer and allows the user to remotely communicate with the 356E Plus. The user may download circuit performance templates, update software revisions, and extract stored data from the 356E Plus. Separate templates may be stored for Copper, Wireless, HFC, or any type of loop required. Individual templates may also be developed for installation tests, maintenance tests and special studies. Stored data can be formatted for reporting, or printed for review. TSC Software Utilities The Test File Definition Editor allows the user to create test templates and test limit files for individual service testing. The Test File Viewer utility allows review of extracted test results and generation of printed reports. Administration Central Office Field Test System Controller (TSC) Modem 356E Plus 923LTS Modem Direct The 923LTS, 356E Plus and TSC form an exciting new concept in Local Loop Testing. If you are "lean and mean," concerned about "productivity" and demand "cost effective solutions" CHECK IT OUT! There's nothing like it anywhere in the industry.

Automated Local Loop Test System Standard Features and Options 356E Plus Central Office Unit Basic Unit Includes Operator's Manual Options Callback Additional Operator's Manual For Information on Pricing and Availability Consult Your Local Distributor Test System Controller (TSC) TSC Software Package Windows-based software used to download circuit, performance templates and update application software, and extract stored data from the 356E Plus. For Information on Pricing and Availability Consult Your Local Distributor 923LTS Hand-held Field Test Unit Basic Unit Includes Operator's Manual, AC Adapter, RJ-48 to RJ-11 Test Cord and Grounding Cable. Options For Information on Pricing and Availability Consult Your Local Distributor Built-in Butt Set Callback (Verifies Switch Translations and Measures Ringing Voltage. Callback is also required in the 356E Plus.) Hits and Jitter Measurements (Impulse Noise, Phase/Amplitude Jitter, Phase/Gain Hits, and Dropouts) Soft Pack Carrying Case Test Cord, RJ-48 to Alligator Clips Cable, RS-232 Additional RJ-48 to RJ-11 Test Cord Additional Grounding Cable Additional Operator's Manual

923LTS Hand-held Field Test Unit Line Interface Specifications Input: 2-Wire Loop Holding: 20 ma 42.5 to 105 VDC open circuit voltage with line resistance of 1700Ω. Compatible with constant current source DC Blocking: 150 VDC Balance: >90 db, 50 to 120 Hz, decreasing 6 db/octave above 120 Hz Termination: 600 or 900Ω or complex imepdence; return loss 30 db from 200 to 4000 Hz, 15 db from 20 to 5000 Hz Listen and Talk: Built-in speaker (standard) Talk capabilities (optional) Return Loss Termination: 600Ω or 900Ω (1%) in series with 2.16 µ (3%) or custom termination AC Bridging Impedance: > 20,000Ω, 50 to 5000 Hz AC Impedance to Ground: > 20,000Ω, tip or ring to ground Signaling: Dial Pulse: 10 PPS, accuracy ± 2 PPS, 60% break, accuracy ±2%, 700 msec. interdigit timing DTMF: ±0.5% of Bell standard frequencies -7.0 dbm0 per tone, accuracy ±0.5 db Timing: 50 msec. On/Off, accuracy 0.5 msec. 923LTS AC and DC Measurements DC Measurements: Voltage Voltage DC Measurement Modes Tip-to-Ring Current: AC Measurements: Voltage Voltage Voltage Frequency Frequency Frequency Ringing: Ring Detect: Termination: +99 VDC to -99 VDC (with overrange indication) 0.1 VDC ±2% of reading, ±0.3 VDC Tip-to-Ring Tip-to-Ground Ring-to-Ground ±125 ma 1 ma DC ±2% of reading, ±1 ma DC 0 to 150 V rms 1 V rms ±2% of reading, ±0.5 V rms 20 to 120 Hz 1 Hz ±1 Hz 40 V rms ±8 V (1 REN) resistor in series with capacitor; impedance = 8000Ω @ 20 Hz, 1.5 watts; impedance 7000Ω @ 70 Hz Isolation: Tip and ring and station ground are isolated from data interface connector, charging connector, and case by more than 500 Volts.

923LTS/356E Plus Send/Receive Performance Specifications Send: Frequency 50 to 5000 Hz 1 Hz ±0.5 Hz Level +1 0.1 db Level 1000 Hz: ±0.1 dbm, 0 to -19 dbm 50 to 5000 Hz: ±0.2 dbm, +1 Distortion: 1 khz 70 db, 0 dbm 200 to 3700 Hz: 65 db, 0 to -16 dbm 100 to 5000 Hz: 50 db, +1 Receive: Frequency 20 to 5000 Hz 1 Hz ±1 Hz Level +10 to -50 dbm 0.1 db Level Accuracy (terminated): 1000 to 1020 Hz: ±0.1 db, 0 to -19 dbm 200 to 5000 Hz: ±0.2 db, +10 to -50 dbm 20 to 200 Hz: ±0.5 db, +10 to -50 dbm Noise: Level +10 to +100 dbrnc 1 db Level 1 db Filters: C-Message, C-Notch, 3 khz Flat Noise-to-Ground: Level +40 to +130 dbrnc 1 db Level 1 db Filters: C-Message, C-Notch, 3 khz Flat 923LTS/356E Plus Test Specifications 3-Tone Gain Slope: Programmable 50 to 5000 Hz Loss: +2.0 db to -20.8 dbm ±0.2 db C-Message Noise: 10 dbrnc to 90 dbrnc ±1 db C-Notch Noise: 1020 Hz 20 dbrnc to 70 dbrnc ±1 db Return Loss: Bands: ERL, SRL High & Low 0 db to +40.0 db ±1 db 3kHz Flat Noise: 20 dbrn to 90 dbrn ±1 db Filter: 3 khz Flat Phase and Amplitude Jitter: (standard and low frequency) 1020 Hz Filters: 20-300 Hz or 4-300 Hz 0-20.0% amplitude, 0-20.0º phase ±5% of reading, ±0.2

923LTS/356E Plus Test Specifications, Continued Impulse Noise/Hits: 1020 Hz Threshold: 50-90 dbrnc Spread: 1-9 db (±1 db) Measurements per Second: 1-99 Phase Hit Threshold: 5-30º (±10%, ±5º) Gain Hit Threshold: 1-8 db (±5 db) Test Length: 1 to 99 minutes (each way) 0 to 999 impulses/hits ±1 impulse/hit 23-Tone Test Transmitter: Composite Individual Tones: Flatness: Frequencies: 0 dbm to -40 dbm Phase: per IEEE 743 ± 0.25 Peak to RMS Ratio: 8.79 Receiver: Attenuation: Envelope Delay Distortion: Frequencies: Signal-to-Noise: Signal-to-Total Distortion: Intermodulation Distortion: (2nd and 3rd order) -13.6 db below Composite Level ± 0.1 db 203.125 to 3640.625 Hz in 156.25 Hz steps ± 10 ppm -40 dbm to -6 dbm ± 0.2 db ± 0.2 db ± 10 µsecs 10,000 µsecs 281.15 to 3562.5 Hz in 156.25 Hz steps ± 2 db from 10 db to 24 db ± 1 db from 25 db to 40 db ± 2 db from 41 db to 45 db ± 2 db from 10 db to 24 db ± 1 db from 25 db to 40 db ± 2 db from 41 db to 45 db ± 2 db from 20 db to 29 db ± 1 db from 30 db to 46 db ± 2 db from 47 db to 55 db ± 3 db from 56 db to 60 db General 923LTS General: Weight: Approximately 20 oz. Size: Approximately 4 Wide, 1.5 High X 9 Long Temperature: 0 to 50º C, operating -20 to + 60º C, storage Humidity: 85% Noncondensing Serial Data Input/Output: 1200, 9600, 38,400 and 115,200 bps Power: 120 VAC, 60 Hz or battery 356E Plus General: Weight: Size: Humidity: Temperature: Power: 7 lbs., 12 lbs. Shipping 3.5 High X 17 Wide X 10 Deep 85% Noncondensing 0-50 º C 120 VAC, 60 Hz @ 0.2 Amp Price and Specifications subject to change without notice 062597.R1 Sage Instruments INSTRUMENTS 240 AIRPORT BOULEVARD FREEDOM, CA 95019-2614 TELEPHONE: (408) 761-1000 FAX: (408) 761-1008 www.sageinst.com