Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

Similar documents
Single Point Flow Monitor SW118 SW119

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Model KBF 115 Constant climate chambers with large temperature / humidity range

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

DMP 331i / DMP 333i LMP 331 i

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

EGM Einthoven Goldberger Module Type 701

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

BASIC PH METER BASIC PH METER KIT

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

Up to 85% higher Service Life due to efficient sealing method.

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Model KBF 1020 Constant climate chambers with large temperature / humidity range

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Level Measurement silometer FMC 420, FMC 423

TUC: Universal thermostat

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Capacitance Level Measurement Electronic insert FEC 12

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Process Transmitter RMA 422

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

USER S MANUAL. FX2N-8AD Analog input block

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

Generator protection relay

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

SCALE & WEIGHT DISPLAYS

PROPORTIONAL VALVES Sentronic plus

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Standard signal metering in wall-mounting case

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

SPACESCAN SERIES SS 02

Mechanical flow switch for On/Off control

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Panel-mounting Thermostats EM Series

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

Inductive sensor With analog output BI15-M30-LI-EXI

Panel-mounting thermostats, type series EM

Process transmitter RMA422

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

Bimetal Temperature Switch

IMPAC Infrared Thermometers

DATA SHEET Panorama Rudder Indicator, TRI-2

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

FLOMAT Electromagnetic Insertion Flowmeter

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Heating thermostat Series AMHs B Operating Instructions 11.06/

Operating instructions

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Inductive sensor NI3-EG08K-Y1-H1341

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Electrical connection

LAUREL ELECTRONICS, INC.

Model ED 23 Drying and heating chambers Classic.Line with natural convection

SAUTER flexotron RDT405 Manual

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Filters for Power Lines (Low Leakage Current)

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

RKSlimlift / EM. Two-stage lifting column

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Photoelectrics Through-beam Type PA18C.T..., DC

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Magnetic Sensor - Incremental EHP

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Absolute Encoders Multiturn

Model KT 53 Cooling incubators with thermoelectric cooling

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Pressure transmitter COMPACT IO-Link,

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

Transcription:

Hygrotest 600 Instruction manual en WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

Contents Introduction...2 Handling instructions...3 Dimensions of measuring instrument...3 Description of functions...4 Standard versions...5 Version options...6 Connection assignment...8 Description of 2 wire technology...8 Connection suggestions for 2 wire technology...9 Current measurement...9 Voltage measurement...10 Attaching ferrite sleeve...11 Installing a digital display...11 Advice on use...12 Adjustment...13 Adjustment with testo 650/400...13 Adjustment with control and adjustment set...14 Maintenance...15 Cleaning the humidity sensor...15 Technical data...16 Ordering data...17 Introduction Dear Customer Thank you for purchasing a Testo product. We hope you will enjoy the benefits of this product for a long time to come and that it will aid you with your work. Please read this instruction manual carefully and familiarise yourself with the operation of the instrument before putting it to use. If problems should occur which you cannot rectify yourself, please consult our Customer Service Department or your nearest distributor. We will do our best to help you quickly and competently to avoid downtimes. EMC according to guideline 2004/108/EEC 2

Handling instructions Please read prior to operation! Do not measure on live parts! Observe sensor measuring ranges! The probes may be damaged if overheated. Observe maximum storage and transport temperature as well as maximum operating temperature (e.g. protect instrument from direct sunlight). The warranty is invalid if inexpertly handled or force is used! Installation, adjustment and calibration work should only be carried out by trained professionals. 41* Dimensions of instrument in mm 120* 105 140 M20x1.5 M16x1.5 M16x1.5 82.5* 52 * Mounting dimensions 5.1* 3 130 Opening Ø 5 mm Note The cable lead-ins differ depending on version

Description of functions The affordable transmitters from the hygrotest 600 series have been developed for a wide variety of HVAC applications but also for industrial drying processes, for example. Depending on design the modular design facilitates wall assembly, duct assembly as well as measurements at inaccessible points (probe can be attached to pipe). The transmitters can be easily calibrated and adjusted on-site via a control and adjustment set (see adjustment guidelines). The user saves time and money when assembling and installing thanks to the industrial standard 4 to 20mA in 2 wire technology and the variable assembly options (rail, wall, duct, separate probes). Advantages of hygrotest 600 Ideal price/performance ratio: - Electronics immune to interference thanks to reverse battery protection, overvoltage protection, EMC compliance to industrial standards - Electrical isolation - Low installation and assembly costs thanks to industrial 4 to 20 ma 2 wire technology - Easy on site calibration and adjustment for humidity and temperature via adjustment set - LED display (optional) - RS 485 Interface (optional) 4

Standard versions Terms W: Wall H: Humidity D: Duct T: Temperature P: Probe -20/+70 C: Standard scaling -20/+70 C Part no. for hygrotest 600 product series: 0555.0600 Example: hygrotest 600 PHT / -20/+70 (cable version with external probe, with humidity and temperature measurement up to + 70 C) hygrotest 600 WH hygrotest 600 WHT -20/+70 C For monitoring ambient air conditions using an external humidity and temperature probe (temperature output only in Hygrotest 600 WHT). 65 12 Scaling: 4 to 20mA = 0 to 100% RH 4 to 20mA = -20 to +70 C (WHT -20/+70 C) Plastic (70 C version) DH / DHT 70 Stainless steel 1.4571 (120 C version) hygrotest 600 DH hygrotest 600 DHT -20/+70 C hygrotest 600 DHT -20/+120 C For duct measurement in compact design using an external humidity and temperature probe. 12 200 Scaling: 4 to 20mA = 0 to 100% RH 4 to 20mA = -20 to +70 C (DHT -20/+70 C) 4 to 20mA = -20 to +120 C (DHT -20/+120 C) Plastic (70 C version) 100 210 12 1.4571 Stainless steel 1.4571 (120 C version) hygrotest 600 PHT -20/+70 C hygrotest 600 PHT -20/+120 C With an external humidity and temperature probe, 2 m long cable, maximum Scaling: 4 to 20mA = 0 to 100% RH 4 to 20mA = -20 to +70 C (PHT -20/+70 C) 4 to 20mA = -20 to +120 C (PHT -20/+120 C) 5

Version options 600 PHT -20/120 600 PHT -20/70 600 DHT -20/120 600 DHT -20/70 600 DH 600 WHT -20/70 600 WH Order Code Analog output B 1 4 to 20 ma (2-wire-technology) Probe Probe material stainless steel 1.4571 Probe material plastic C 1 Standard probe length incl. sensor protection filter 65 65 200 200 200 100 210 C 2 Special probe length, stainless steel incl. sensor protection cap... DH -20/+120 C: min 100mm; PHT -20/+120 C: min. 150mm; max. 800mm C 3 Special probe length, plastic, 100 mm, incl. sensor protection cap Cable D 1 Standard cable length 2 m D 2 Special cable length up to tip of probe...m (min. 250 mm; max.2 m) Adjustment F 1 Humidity inaccuracy ±2 %RH Sensor protection caps G 1 Stainless steel sintered cap G 2 Wire mesh filter G 3 PTFE sintered filter G 4 Slid metal filter G 5 ABS-cap slit Displays H 1 Display double-spaced - loop feed with maximum load 50 Ohm H 2 Display double-spaced - external supply with max. load 500 Ohm H 3 Display double-spaced - with RS485 - no analog outputs possible H 4 Display double-spaced - with RS485 -analog output possible H 5 Display double-spaced with RS485 and 2x2 limit signal outputs - analog outputs possible 6

Version options 600 PHT -20/120 600 PHT 20/70 600 DHT 20/120 600 DHT -20/70 600 DH 600 WHT -20/70 600 WH Order Codes H 6 Display double-spaced with 2x2 limit signal outputs - analog outputs possible H 7 Simple display single-space - loop feed with maximum load 50 Ohm Scaling K 1 Standard scaling channel 1 (4 to 20 ma = 0 to 100 %RH) K 2 Special scaling channel 1 (4 to 20 ma =... choosen unit out of L Note: please specify the scaling range L 1 Realtive humidity (%RH) L 2 Dewpoint ( Ctd) L 3 Dewpoint ( Ftd) M 1 Standard scaling channel 2 (4 to 20 ma = temperature scaling ( C) -20/70-20/70-20/120-20/70-20/120 M 2 Special scaling channel 2 (4 to 20 ma =... choosen unit out of N Note: please specify the scaling ranges N 1 Temperature ( C) N 2 Temperature ( F) - standard - optional 7

Connection assignment Connection socket for scaling adapter or testo 400/650 instrument for 1-point adjustment In order to avoid losing the adjustment values, adjustment buttons should only be activated if the adjustment container is screwed on (see page 10, adjustment with control and adjustment set). enable switch 1 switch 2 75,3%rH calibr. 11,3%rH calibr. +%rh -%rh + C - C 1 2 3 4 } 1 + RH 2 wire techn. 4 to 20 ma = 0 to 100 %RH, 2 - RH 3+ C 4 - C } 2 wire techn. 4 to 20mA = ^-20 to +70 C (with WHT -20/70 / DHT -20/70 / PHT -20/70) 2 wire technology 4 to 20 ma ^= -20 to +120 C (with DHT -20/120 / PHT -20/120) Description of 2 wire technology 2 wire transmitters are used to convert non-electrical parameters, e.g. temperature, pressure, relative humidity etc. to an electrical standard signal of 4 to 20 ma. The transmitters are connected to a d.c. voltage source by means of 2 cables. The power consumption of the transmitter from the d.c. current source changes linearly in the range from 4 to 20 ma, depending on the parameter being measured. The advantages of the two wire system are easy installment and problem-free connection. The length of the cables does not influence the measured signal. A further additional advantage is the so-called live zero signal i.e. 0 parameter corresponds to a current of 4 ma. In this way, this value is also clearly transmitted and cannot be confused, for example, with a system which is switched off or an ununterrupted line. 8

Connection suggestions for 2 wire technology Current measurement Option 1: Transmitter 230V/ 110V 24 V DC 1 2 3 4 4 to 20 ma = -20 to +120 C / +70 C for WHT/DHT/PHT 4 to 20 ma = 0 to +100 %RH Option 2: 4 to 20 ma = 0 to +100 %RH Transmitter 230V/ 110V 1 2 3 4 4 to 20 ma = -20 to +120 C/+70 C for WHT/DHT/PHT hygrotest 600 with displays H1, H3, H7 is supplied via the humidity connections. The temperature output, if available, can only function if a humidity circuit with 24 V is connected. This also applies in combination with all displays. 9

Connection suggestions for 2 wire technology Voltage measurement Long signal paths can be a problem when transmitting voltage signals (cable resistance, interference etc.). It is advisable to use current signals for safe transmission (4 to 20 ma). Shunt resistances between 50 Ω or 500 Ω (50 Ω: 0.2 to 1 V, 500 Ω: 2 to 10 V) are parallel connected to the multimeter, controller etc. when measuring voltage (0.2 to 1 V, 2 to 10 V) (see Figure). Advantage - Reliable signal due to power transmission - Recognises disconnected cable ( live zero ) Voltage measurement from 2 to 10 V or 2 to 10 V is not possible in instruments with displays H1, H3, H7 since they are loop-fed. Transmitter 1 2 3 4 %RH 50Ω (500Ω) 50Ω (500Ω) 0.2...1V (2...10V) = -20...+70 C 0.2...1V (2...10V) = 0...+100 %RH 10

Bohrvorlage für Messwertumformer hygrotest 600 Drilling template for the transmitter hygrotest 600 66mm Bohrdurchmesser ist abhängig von der Montageart. Drilling hole diameter depends on mounting type. 66mm 66mm 125mm für D-Varianten for D versions 51mm ø 5mm 82,5mm

Attaching ferrite sleeve for 2 wire technology Note To comply to EMC rules, all outside cables have to carry ferrite sleeves. These sleeves are delivered with the instrument. Please insert the analog output signal cable of each channel through one of the sleeves (outside the housing). Connection socket for scaling adapter or testo 400/650 instrument for 1-point adjustment Slide switch Screws Cable connector Fig. 1 Installing a digital display Max. load 50 Ω with displays H1, H3, H7 - Remove housing cover from hygrotest 600. Disconnect electrical supply. - In displays H1, H7 move right slide switch (SW11) from the bottom position to the upper OFF position (Fig. 1). In displays H2, H3, H4, H5, H6 switch remains on ON position. - Remove 4 screws from the instrument board (Fig.1). - Attach cable connector (Fig. 2) of display (watch out for guide pin) to connection socket (Fig. 1). Fig. 2 Spacing pins - Screw in spacing pins on instrument board (Fig. 3). - Mount display board with screws on spacing pins. Fig. 3 - Perform electrical connection. - Screw on new housing cover (with window) 11

Advice on use Seal The hygrotest 600 humidity and temperature transmitter is employed in a wide variety of industrial applications. Some advice which can lead to better measuring results is given below. General The better the process air flows past the probe, the sooner the transmitter will display the correct temperature and humidity. - Low flow rate and uncontaminated atmosphere Use slotted sensor caps (0554.0755) to achieve a faster response time. - Atmosphere containing dust or particles Use a PTFE sintered cap (0554.0647) to protect the sensor against contamination. - Strong flow rates up to 10 m/s with few particles Use a stainless steel sintered cap (0554.0647). - Flow rates >10 m/s or lots of particles Fit a deflector in the direction of flow and mount the probe away from the wind with a suitable sintered cap. - Applications in which drips may form Install the probe in such a way that condensate can run off. Use dew protection (0554.0166)(see drawing). You may need to use a PTFE sintered cap with a drill hole (0554.9913). - Measuring humidity in chemical gases Gas concentrations deviating from the natural ambient atmosphere may have an influence on the values or damage the humidity sensor. - For installation support please contact your local testo partner. 12

Adjustment Two options are available for adjustment: 1. Adjustment with the reference instrument testo 650/400 and precision humidity probe from testo. 2. Adjustment with reusable saturated salt solutions 11.3 %RH and 75.3 %RH (control and adjustment set). Micromatch connection Display port and port for scaling adapter or handheld instrument for adjustment. Protection pin on right Adjustment with testo 650/400 If the testo 650/400 is used for adjustment, you will also need the cable, Part no. 0409.0214 and precision humidity probe 0636.9741. Note The following describes a 1-point adjustment. This is only advised if hygrotest 600 is operated close to the adjustment point (working point). Before opening the transmitter: - interrupt the control circuit of the transmitter; Heated humidity probe Reference probe 26.4%rF 27.2%rF 25.1 C 26.2 C Caution! 1. Remove the cover of the transmitter. 2. Plug the connecting cable into the micromatch connection on the transmitter board or display board (see diagram). 3. Set up transmitter control circuit. If you are using a display, you must interrupt communication between the display and the transmitter. To do this, press the key for at least 3 seconds. Communication of the display is interrupted and the display unit shows dashes (- - - -). 4. Plug the precision humidity probe into the right port and the connecting cable into the left port of the testo 650 or testo 400 reference instrument. 5. Attach the precision humidity probe immediately adjacent to the probe of the transmitter in order to obtain comparable values. 6. Switch on testo 650/400. The two-part display will show the values of the transmitter on the left, and the values of the reference instrument on the right. 13

Adjustment 7. Push on OK button of the testo 400/650. Choose menu probe. Press OK again and choose menu Adjustment. After a further push of the OK button the humidity and temperature value of the testo 400/650 is sent to Hygrotest. Humidity adjustment in the transmitter is cancelled via Probe Reset and set back to previous values. Now take off the cable between testo 400/650 and the Hygrotest transmitter. 8. If you are using a display, reestablish communication between the display and the transmitter by pressing the key briefly. 9. Close the transmitter and reestablish connections. Note To ensure accuracy, use a regularly calibrated reference instrument and precision humidity probe to carry out the adjustment. Note An adjustment period of at least 60 minutes is advised at a constant temperature of 25 C. Note Adjustment of the transmitter is possible from firmware version 1.22 in the testo 650 or testo 400. Adjustment with control and adjustment set A 2-point humidity adjustment of the transmitter can be performed using the control and adjustment set. For other adjustment instructions, please refer to the Control and adjustment set instruction manual. Note For the adjustment process, if a display is connected (H1, H2, H3, H4, H5 or H6), please refer to the Display instruction manual. 1. Remove the sensor cap. 2. Note the immersion depth of the probe. 3. Screw the humidity container to the probe with a suitable adapter. 4. Perform the adjustment at a constant temperature. 5. Wait to the end of the compensation period (recommended: >6h). 6. Carry out adjustment. To do this, press the key for the corresponding values (11.3 %RH or 75.3 %RH) and the Enable key at the same time (see top drawing on page 13). Note The adjustment period is at least 180 minutes at a constant temperature of 25 C. 14

Maintenance Cleaning the sensor For cleaning the humidity sensor isopropanol should be used. Not suitable is spirit, as spirit contains small tracks of oil. Rinse the humidity sensor in isopropanol until no dirt is visible anymore. Afterwards wash up the humidity sensor with distilled water. Do not towel the sensor with a cloth, as the lid electrode could be damaged. 15

Technical data hygrotest 600 Housing: Material: ABS, grey colour RAL 7035 Dimensions: 130 x 105 (140) x 52 mm Humidity sensor: Temp. sensor Screw connections: 2 x M 16 x 1.5 Ambient temp.: -10 to +70 C Storage temp.: -40 to +80 C Protection class: IP 65 Testo sensor plugged in with: DHT -20/+120 C and PHT -20/+120 C With other types the sensor is soldered NTC plugged in with: DHT -20/+120 C and PHT -20/+120 C With other types the sensor is soldered Measuring ranges: Humidity: 0 to 100% RH Temperature: -20 to +70 C (WHT -20/70/ DHT -20/70 / PHT -20/70-20 to +120 C (DHT -20/120 /PHT -20/120) Temp. coefficient: 0.05%RH/ C for temp. deviating from 25 C Accuracy Humidity: ±2% RH (0 to 90 %RH) ±3% RH (90 to 100 %RH) Accuracy Temperature: ±0.3 C (-20 to +50 C) 1.5% of reading >50 C Outputs can be scaled Pressure tightness of probe: 4 bar (DHT -20/120 / PHT -20/120), at +10 to +40 C Vacuum-tightness of probe: Approx. -0.5 bar (DHT -20/ 120 / PHT -20/120) The other types are designed for atmospheric conditions. Electrically isolated outputs: Power supply: Max. load without display: Max. load with display H1: Power supply with display H1: Reaction time: integration time of 1s Humidity and temperature (WHT, DHT, PHT only ) 24 V DC (10 to 30 V DC) At 10 V, 100 Ohm At 18 to 30 V, 500 Ohm 20 to 30 V, 50 Ohm At least 20 V t90 approx. 10 to 20 s We recommend an in the case of very quick analog recorders or PLC inputs. Temperature resistance Probe and cable: 120 C (DHT -20/120 / PHT -20/120) 70 C (WH, WHT -20/70, DH, DHT -20/70, PHT -20/70) Analog outputs: Humidity Resolution: Accuracy: Drift: Temperature Resolution: Accuracy: Drift: Humidity and temperature: 0.02 ma 0.04 ma 0.001 ma/ C 0.02 ma 0.04 ma 0.003 ma/ C 4 to 20 ma in 2 wire technology (WHT, DHT, PHT only) 16 EMC: according Guidline 89/336 EEC Probe material: Polycarbonate(PC) except with DHT -20/120 / PHT -20/120, here 1.4571 stainless steel is used. All data referring to a rated temperature +25 C. Warranty 2 years

Ordering data Accessories for hygrotest 600 Designation Part. No. Metal protection cage 0554.0755 Stainless steel sintered cap 0554.0647 Cap with wire mesh filter 0554.0757 PTFE sintered filter 0554.0759 Dew protection 0554.0166 for highest humidity Aluminium Wall bracket for probe with cable 0554.1798 for PHT Single duct screw-on 0554.1793 connection for DH/DHT 17

Ordering data Accessories for hygrotest 600 Designation Part. No. Duct screw-on connection 0554.1794 for DHT/PHT (not pressure tight) Pressure-tight stainless steel fitting 1/2 with cutting ring up to 10 bar 0554.1795 Pressure-tight stainless steel fitting 1/2 with PTFE ring, adjustable up to 6 bar 0554.1796 for DH/DHT and PHT Flange for screw connections to DIN 2576, stainless steel 0554.1797 to be used in conjunction with pressure tight fitting. Control and adjustment set 75.3 % 0554.0638 Control and adjustment set 11.3 % and 75.3 % 0554.0660 Power supply 230 V - 24 V DC 0554.1742 Connecting cable for reference hand-held unit testo 400/650, cable length 1.5 m 0409.0214 18

19

testo AG Postfach 11 40, 79849 Lenzkirch Testo-Straße 1, 79853 Lenzkirch Telefon: (07653) 681-0 Fax: (07653) 681-100 E-Mail: info@testo.de Internet: http://www.testo.com 0973 6004 en 07