Coils for solenoid valves

Similar documents
Nessie Coils for VDH and VDHT valves

8 Installation Equipment

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

EXPlora. Introduction

Pendant Light Fitting IEC Series 6470/2

7 Lighting Technology

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

I Ex-protected connectors exlink I

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Single Point Flow Monitor SW118 SW119

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath

Size B INDUSTRIAL STANDARD

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

Bimetal Temperature Switch

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

COILS COUPLING TABLE COILS/ELECTROPILOTS ELECTROPILOTS/SOLENOID VALVES. Electropilots. Coils. Solenoid valves G6 GL6.

Level Measurement silometer FMC 420, FMC 423

Contactors and Contactor Assemblies

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Horn loudspeaker, Ex proof, short/long flare

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

82540/ /2-way diaphragm valves

Operating instructions

Modular Lube Lubrication Systems System Controls

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Linear flow control with actuator IFC

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Capacitance Limit Detection nivotester FTC 420/421/422

Connecting cables for valves, round plug connectors Product range overview

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Connecting cables NEBS, for sensors

Filters for Power Lines (Low Leakage Current)

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

SERIES 400 SERIES 620

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Safety dialogue solutions

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

PROPORTIONAL VALVES Sentronic plus

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Mechanical flow switch for On/Off control

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Absolute Encoders Multiturn

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

TUC: Universal thermostat

-V- New. Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

GV2ME. Main. Device short name. Device application

Heating thermostat Series AMHs B Operating Instructions 11.06/

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Feed-through terminal, 2.5 mm², Screw connection, Wemid, dark beige, TS 35

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

DMP 331i / DMP 333i LMP 331 i

Connectors for mains connection IEC

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Inductive sensor NI3-EG08K-Y1-H1341

A V 50Hz / V 60Hz

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Process transmitter RMA422

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Pendant Light Fittings Series 6050

Datasheet - SRB301LC 24VAC/DC

Transcription:

MAKING MODERN LIVING POSSIBLE Technical leaflet Coils for solenoid valves www.danfoss.com

B and A coils Encapsulated coils with long operating life, even under extreme conditions Standard coils for a.c. or d.c. Standard coils from 12 V to 400 V, 50, 60 or 50/60 Hz Standard coils available with 3 core cable, Danfoss terminal box or for DIN plugs Coils can be fitted without use of tools Coils can only be removed with use of tools Contents Enclosure Page B-series,13.5 mm system a.c. d.c. BA IP 00-IP 65 9 W 15 W 3 BD IP 00-IP 65 15 W - 3 BB IP 00-IP 65 10 W 18 W 4 BE/BF IP 67 10 W 18 W 5 BG IP 67 12 W 20 W 6 BN ( hum-free) IP 67 20 W - 7 BO ( EEx miit4) IP 67 10 W 10 W 8 BP ( Ex mbiit4) IP 67 12 W 10.5 W 9 A-series, 9 mm system AB IP 00-IP 65 4.5 W 5 W 10 AC IP 00-IP 65 7 W 10 W 10 AK IP 00-IP 65-3 W 11 AL IP 00-IP 65 4 W - 11 AM IP 00-IP 65 7.5 W 9.5 W 11 Connector for coil type AB and AC IP 65 12 connector for coil type AK, AL, AM, BA, BD, BB IP 65 13 (LED + Varistor) Indicator Connector for coil type AK, AL, AM, BA,BD,BB IP 65 14 (LED + Varistor) Indicator Connector for coil type AB and AC IP 65 15 Universal electronic multi-timer Type ET 20 M IP 00-IP 65 16 2 IC.PD.600.A5.02 / 520B4445

BA/BD Coils Weight 0.16 kg L [mm] Without cable plug 54 With protective cap 71 With cable plug 79 Technical data Design In accordance with VDE 0580 Voltage tolerance 220 and 380 V a.c. coils: +10%, -15%. 230/400 V a.c. coils: +6%, -10%. Other a.c. coils with NC valve: +10%, -15% Other a.c. coils with NO valve and all d.c. coils: ± 10%, cut in BA 39 VA a.c. coils only BD 54 VA Connection Spade connector in accordance with DIN 43650 form A Enclosure, IEC 529 IP00 with spade connec. IP 20 with protective cap, IP 65 with cable plug Ambient temperature BA Max. +40 C BD Max. +50 C Ordering BA/BD Coils Compatibility for Valve type See data sheets for valves BA BD 9 W 19VA 15 W 15 W 29 VA Contact Danfoss for delivery of coils for other voltages Supply voltage Frequency Hz BA024A 24 a.c. 042N7508 BA048A 48 a.c. 042N7510 BA115A 115 a.c. 042N7512 50 BA230A 220-230 a.c. 042N7501 BA240A 240 a.c. 042N7502 BA380A 380-400 a.c. 042N7504 BA024B 24 a.c. 042N7520 BA115B 115 a.c. 60 042N7522 BA220B 220 a.c. 042N7523 BA012D 12 d.c. 042N7550 d.c. BA024D 24 d.c. 042N7551 BD024A 24 a.c. 042N7597 50 BD230A 230 a.c. 042N7591 Symbol Description Enclosure Protective cap (pack of 100 pcs.) IP 20 018Z0282 Cable plug according to DIN 43650-A PG 11 IP 65 042N0156 1) 1) Ordering see page 13 IC.PD.600.A5.02 / 520B4445 3

Coils type BB-Clip on version Weight 0.24 kg L [mm] Without cable plug 62 With protective cap 77 With cable plug 85 Technical data Design In accordance with VDE 0580 Voltage tolerance 220 and 380 V a.c. coils: +10%, -15%. 230/400 V a.c. coils: +6%, -10%. Other a.c. coils with NC valve: +10%, -15% Other a.c. coils with NO valve and all d.c. coils: ± 10%, cut in 44 VA a.c. coils only Connection Spade connector in accordance with DIN 43650 form A Enclosure, IEC 529 IP 00 with spade connec. IP 20 with protective cap, IP 65 with cable plug Ambient temperature Max. +50 C /+80 C - see table below for details Ordering BB Coils Compatibility for Valve type All 2/2-way valves 10 W 21 VA 18 W Contact Danfoss for delivery of coils for other voltages Supply voltage Frequency Hz Ambient temperature [ C] BB024AS 24 a.c. 018F7358 BB115AS 115 a.c. 018F7361 BB230AS 220-230 a.c. 50 018F7351 80 BB240AS 240 a.c. 018F7352 BB380AS 380-400 a.c. 018F7353 BB024BS 24 a.c. 60 018F7365 BB110CS 110 a.c. 018F7360 50/60 BB230CS 220-230 a.c. 018F7363 50 BB012DS 12 d.c. 018F7396 d.c. BB024DS 24 d.c. 018F7397 Symbol Description Enclosure Protective cap (pack of 100 pcs.) IP 20 018Z0282 Cable plug according to DIN 43650-A PG 11 IP 65 042N0156 1) 1) Ordering see page 13 Description Application O-ring ( pack of 10 pcs.) Sealing of clip-on coil 018F0094 4 IC.PD.600.A5.02 / 520B4445

Coils type BE/BF-Clip on version Weight 0.30 kg L [mm] With terminal box 94 With 1 m cable 65 Technical data Design In accordance with VDE 0580 Voltage tolerance 220 and 380 V a.c. coils: +10%, -15%. 230/400 V a.c. coils: +6%, -10%. Other a.c. coils with NC valve: +10%, -15% Other a.c. coils with NO valve and all d.c. coils: ± 10%, cut in 44 VA a.c. coils only Connection BE - coils : Terminal box, Pg 13.5; BF - coils : 1 m 3-core flying lead Enclosure, IEC 529 IP 67 Ambient temperature Max. +50 C /+80 C - see table below for details Ordering BE/BF Coils Compatibility for Valve type 10 W 21 VA Supply voltage Frequency Hz Ambient temperature [ C] BE - coils With terminal box 018F6707 BF - coils With cable BE024AS 24 a.c. 018F6257 BE048AS 48 a.c. 018F6709 018F6259 BE115AS 115 a.c. 018F6711 018F6261 50 BE230AS 220-230 a.c. 018F6701 018F6251 BE240AS 240 a.c. 80 018F6702 018F6252 BE380AS 380-400 a.c. 018F6703 018F6253 All B - 2/2- way valves. BE024BS 24 a.c. 018F6715 018F6265 BE115BS 115 a.c. 60 018F6710 018F6260 BE220BS 220 a.c. 018F6714 018F6264 BE110CS 110 a.c. 018F6730 018F6280 50/60 BE230CS 230 a.c. 018F6732 018F6282 50 BE012DS 12 d.c. 018F6756 18 W d.c. BE024DS 24 d.c. 018F6757 Contact Danfoss for delivery of coils for other voltages Application O-ring ( pack of 10 pcs.) Sealing of clip-on coil 018F0094 Danfoss terminal box for type BN, BE and BG coils IP 67 Enclosure 018Z0081 Danfoss terminal box with LED indication for type BN, BE and BG coils 48-220 V d.c. 24-250 V a.c., 50/60 Hz 018Z0089 IC.PD.600.A5.02 / 520B4445 5

Coils type BG-Clip on version Weight 0.50 kg L [mm] With terminal box 112 Technical data Design In accordance with VDE 0580 Voltage tolerance 220 and 380 V a.c. coils: +10%, -15%. 230/400 V a.c. coils: +6%, -10%. Other a.c. coils with NC valve: +10%, -15% Other a.c. coils with NO valve and all d.c. coils: ± 10%, cut in 55 VA a.c. coils only Connection Terminal box; Pg 13.5 Enclosure, IEC 529 IP 67 Ambient temperature Max. +80 C Ordering BG Coils Compatibility for Valve type All 2/2-way valves. 12 W 26 VA 20 W Contact Danfoss for delivery of coils for other voltages Supply voltage Frequency Hz BG024AS 24 a.c. 018F6807 BG110AS 110 a.c. 018F6811 BG230AS 220-230 a.c. 50 018F6801 BG240AS 240 a.c. 018F6802 BG380AS 380-400 a.c. 018F6803 BG024BS 24 a.c. 018F6815 BG110BS 110 a.c. 60 018F6813 BG220BS 220 a.c. 018F6814 BG012DS 12 d.c. 018F6856 d.c. BG024DS 24 d.c. 018F6857 Description Application O-ring ( pack of 10 pcs.) Sealing of clip-on coil 018F0094 Danfoss terminal box for type BN and BG coils IP 67 Enclosure 018Z0081 Danfoss terminal box with LED indication 48-220 V d.c. 24-250 V a.c., 50/60 Hz 018Z0089 6 IC.PD.600.A5.02 / 520B4445

Coils type BN-Clip on version Hum-free coil Weight 0.60 kg L [mm] With 1 m cable 112 Technical data Design In accordance with VDE 0580 Voltage tolerance 220 and 380 V a.c. coils: +10%, -15%. 230/400 V a.c. coils: +6%, -10%. Other a.c. coils with NC valve: +10%, -15% Other a.c. coils with NO valve and all d.c. coils: ± 10%, cut in 24 VA Connection 1 m 3-core flying lead ; Pg 13.5 Enclosure, IEC 529 IP 67 Ambient temperature Max. +50 C Ordering BN Coils Compatibility for Valve type Supply voltage Frequency Hz All 2/2-way valves. 20 W 26 VA BN230CS 220-230 a.c. 50/60 018F7301 O-rings ( pack of 10 pcs.) Sealing of clip-on coil 018F0094 IC.PD.600.A5.02 / 520B4445 7

Coils type BO Eex m II T4 For explosion-risk environments, such as where flammable liquids and gases are produced, transported or tapped Approvals for use in Zone 1 according to Directive 94/9/EC (ATEX 100A) EN50014 and EN50028 Medium temperature: Up to +90 C Ambient temperature: Up to +40 C IP 67 version with 5 m 3-core flying lead Seal kit as a.c.cessory for extremely wet and aggressive environments (please contact Danfoss) Technical data Voltage tolerance ± 10% Connection 5 m 3-core flying lead Enclosure, IEC 529 IP 67 Ambient temperature -40 C 60 C Media temperature Max. +90 C Ordering BO Coils Conformity certification EX DEMKO 99ATEX 128981X Compatibility for Valve type All B-series valves Supply voltage Frequency Hz BO024C 24 a.c. 018Z6595 BO048C 48 a.c. 018Z6594 10 W 21 VA BO110C 110 a.c. 50/60 018Z6593 BO230C 230 a.c. 018Z6592 BO240C 240 a.c. 018Z6591 10 W BO024D 24 d.c. d.c. 018Z6596 Description Application Seal kit Wet environment 018Z0090 Dimensions and weight Weight : 0.60 kg 8 IC.PD.600.A5.02 / 520B4445

Coils type BP EEx m II T4 The coils are suitable for use in installations where flammable liquids and gases are produced, transported or tapped Approved for use in Zone 1 according to Directive 94/9/EC (ATEX 100A) EN60079-0 : 2006 EN60079-18 : 2004 EN50281-1 - 1 : 1998 Grade of enclosure IP 67 Supplied with 3 m moulded-in 3-core cable Technical data Voltage tolerance ± 10% Connection 3 m 3-core cable Enclosure, IEC 529 IP 67 Ambient temperature Max. -40 C +60 C Media temperature Max. +90 C Ordering BP Coils Conformity certification EX DEMKO 99ATEX 125688X Compatibility for Valve type Supply voltage Connection All B-series valves 12 W 12 W 10.5 W BP024A BP230A BP024D 24 V 50 Hz 220V 50 Hz 24 V d.c. 3 m 018Z6643 018Z6653 018Z6623 Description Application Seal kit Wet environment 018Z0090 Dimensions Moulded-in 3 m, 3-core cable Weight approx. 0.33 kg Special requirements: The supply must be secured against a too high power comption in case of a short circuit. IC.PD.600.A5.02 / 520B4445 9

Coils type AB and AC AB Coil AC Coil Weight 0.05 kg L [mm] Without cable plug 40 With cable plug 56 Technical data 1,411 mm In accordance with VDE 0580 Voltage tolerance ± 10%, cut in AB 9.5 VA a.c. coils only AC 15.7 VA a.c. coils only Connection Spade connectors, 6.3 x 0.8 mm Enclosure, IEC 529 IP 00 with spade connector, IP 65 with cable plug Ambient temperature AB Max. +50 C AC Max. +50 C Ordering AB/AC Coils 1,411 mm See data sheets for valves AB AC Contact Danfoss for delivery of coils for other voltages Supply voltage Frequency Hz AB024C 24 a.c. 042N0802 4.5 W AB110C 110 a.c. 042N0804 6.3 VA 50/60 AB230C 220-230 a.c. 042N0800 AB240C 240 a.c. 042N0801 5 W AB012D 12 d.c. 042N0806 d.c. AB024D 24 d.c. 042N0803 AC024C 24 a.c. 042N0823 7 W AC110C 110 a.c. 042N0825 10 VA 50/60 AC230C 220-230 a.c. 042N0821 AC240C 240 a.c. 042N0822 10 W AC024D 24 d.c. d.c. 042N0824 Symbol Description Enclosure Cable plug for 6.3 x 0.8 mm spade connectors IP 65 042N0139 1) 1) Ordering see page 12 10 IC.PD.600.A5.02 / 520B4445

Coils type AK, AL and AM AK Coil AL Coil AM Coil Technical data Design In accordance with VDE 0580 Voltage tolerance ± 10%, cut in AL 10 VA AM 22.5 VA a.c. coils only Connection Spade connector in accordance with DIN 43650 form A Enclosure, IEC 529 IP 00 with spade connector, IP 65 with cable plug Ambient temperature AL Max. +50 C AM Max. +50 C Ordering AK/AL/AM Coils Compatibility for Valve type See data sheets for valves AM 7.5 W 15 VA 9.5 W Supply voltage Frequency Hz AM024C 24 a.c. 042N0842 AM110C 110 a.c. 042N0845 50/60 AM230C 220-230 a.c. 042N0840 AM240C 240 a.c. 042N0841 AM012D 12 d.c. 042N0848 AM024D 24 d.c. d.c. 042N0843 AL 4W AL230C 230 a.c. 50/60 042N0864 AK 3 W AK024D 24 d.c. d.c. 042N0844 Contact Danfoss for delivery of coils for other voltages Symbol Description Enclosure Protective cap (pack of 100 pcs.) IP 20 018Z0282 Cable plug according to DIN 43650-A PG 11 IP 65 042N0156 1) 1) Ordering see page 13 Dimensions and weight Weight 0.10 kg L[mm] Without cable plug 48 With protective cap 64 With cable plug 72 IC.PD.600.A5.02 / 520B4445 11

Features Connector Industrial standard 11 mm For use with Danfoss coil type AB and AC a.c./d.c. all voltages up to 250 V Enclosure: Up to IP 65 Ambient temperature: Up to +80 C Technical data Type GM 209 N (Bla.c.k) Design DIN 43650-B Cable gland PG 9 Poles 2 + l Max. voltage 250 V a.c./d.c. Approvals CSA Protection class IP 65 (IEC 60529) Max. operating current 16 A Contact resistance 4m Ω Cable diameter 4,5 to 7 mm Wire cross section Max. 1,5 mm 2 Ambient temperature -25 to + 80 C Materials Contacts: CuZn (Tin plated) Terminal block: PA Flat gasket: NBR Housing: PA Ordering Symbol Description Cable plug for 6.3 x 0.8 mm spade connectors Suitable for coil types AB + AC 042N0139 Dimensions and weight Weight 0.023 kg 12 IC.PD.600.A5.02 / 520B4445

Features Connector For use with Danfoss coils type AK, AL, AM, BA, BD and BB AC/DC all voltages up to 250 V Enclosure: Up to IP 65 Ambient temperature: Up to +125 C Technical data Type GDM 2011 J (Grey) Design DIN 43650-A Cable gland PG 11 Poles 2,3 + PE Max. voltage 250 V a.c./d.c. Approvals CSA Protection class IP 65 (IEC 60529) Max. operating current 16 A Contact resistance 4m Ω Cable diameter 6 to 9 mm Wire cross section Max. 1,5 mm 2 Ambient temperature -40 to + 125 C Materials Contacts: CuSn (Tin plated) Terminal block: PA Profiled gasket: NBR Housing: PA Ordering Symbol Description Cabel plug according to DIN 43650-A PG 11 Suitable for coil types AK, AL, AM, BA, BD, BB 042N0156 Dimensions and weight Weight 0.031 kg IC.PD.600.A5.02 / 520B4445 13

Features (LED + Varistor) Indicator Connector For use with Danfoss coils type AK, AL, AM, BA, BD and BB 24 V a.c./d.c. and 230 V a.c. versions Enclosure: Up to IP 65 Ambient temperature: Up to +60 C Technical data Design EN 175301-803 A Supply voltage tolerance ± 10% consumtion Max. 5 ma Protection class IP65 (IEC 60 529) Max. operating current 1,5 A clamping contact Contact resistance 4 m Ω Protection against wrong polarity yes Cable diameter 6 to 8 mm and 8 to 10 mm Wire cross section Max. 1,5mm 2 Ambient temperature -25 to + 60 C Materials Contacts: CuZn, Cu/Sn-plated Terminal block: PA6 + 30% FG, bla.c.k Flat gasket: NBR LABS-free Housing (translucent): PA6 Wire holder: PA6.6 + 50% FG P7,5 bla.c.k Ordering 1,411 mm LED colour Build in VDR 1) resistor 24 V a.c./d.c. Red Yes 042N0263 230 V a.c. Red Yes 042N0265 1) Protects against voltage peaks Suitable for coil types AK, AL, AM, BA, BD, BB Dimensions and weight Weight 0.027 kg 14 IC.PD.600.A5.02 / 520B4445

Features (LED + Varistor) Indicator Connector For use with Danfoss coil type AB and AC 24 V a.c./d.c. and 230 V a.c. versions Enclosure: Up to IP 65 Ambient temperature: Up to +60 C Technical data Design Industrial form Supply voltage tolerance ± 10% consumtion Max. 5 ma Protection class IP 65 (IEC 60 529) Max. operating current 1,5 A clamping contact Contact resistance 4m Ω Protection against wrong polarity yes Cable diameter 5 to 6 mm and 6 to 9 mm Wire cross section Max. 1 mm 2 Ambient temperature -25 to + 60 C Materials Contacts: CuZn, Cu/Sn-plated Terminal block: PA6 + 30% FG, bla.c.k Flat gasket: NBR LABS-free Housing (translucent): PA6 Wire holder: PA6.6 + 50% FG P7,5 bla.c.k Ordering Voltage LED colour Build in VDR 1) resistor 24 V a.c./d.c. Red Yes 042N0267 230 V a.c. Red Yes 042N0269 1) Protects against voltage peaks Suitable for coil types AB, AC Dimensions and weight Weight 0.027 kg IC.PD.600.A5.02 / 520B4445 15

Features Universal electronic multi-timer Type ET 20 M Outside adjustments Light weight and small size External adjustable timing from 1 minute to 45 minutes with 1 to 15 seconds drain open One solid state timer fits all coil voltages from 24-240 V a.c Light diodes for indication All in one unit Manual override (test button). Technical data Type ET 20 M Voltage rating Enclosure Electrical connection Ambient operating temperature range Function Interval timer On timer 24-240 V a.c/ 50-60 Hz. Max. 20 Watt IP 00, IP 65 with cable plug DIN connector ( DIN 43650-A) -10 C to +50 C Start with pulse 0-45 min. 0-15 Sec. Ordering Voltage Suitable for coil types 24-240 V a.c. 042N0185 AK, AL, AM, BA, BD, BB Dimensions and weight Weight : 0.084 kg 16 IC.PD.600.A5.02 / 520B4445 Produced by Metaphor 08-2011