Sprite TL Quick Start Guide

Similar documents
Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

INTRODUCTION INSTALLATION LIGHTNING RETARDING LOOPS. Figure 1. Relay Box Antenna Connections. Relay Box Cable Connections

Product Identification

Installation And Programming Guide

MWT-FM. Operation Manual. FM Single Channel Transmitter. man_mwtfm.

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

TUSKIN Equipment Corporation

Installation And Programming Guide

QCA9-33 Active Combiner

Master Time Clock MTC Users Manual

NS-3 RF Noise Source Operation Manual

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

Installation Manual SaVi Note Underwater LED Light

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

QDA4-44 RF Amp/Combiner

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

Atlona HDBaseT-Lite Transmitter over Single CAT5e/6/7

Noise Detector ND-1 Operating Manual


Operation Manual VMS 3.0 Video System

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Electronic M.O.P Card. Instruction Manual Model D

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Linear Array with Intensity Adjustment

Electronic converter for level transmitters MT03L Instructions manual

MYE TV Audio Grabber

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

HDMI Extender over UTP Cable

ALPHA Personal Priority Display User Manual

Tube Rotator. User Guide. Version 1.2

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

TAC1 Telephone Entry System

Install Guide Incredible Technologies, Inc. All Rights Reserved

Installation and Operation Manual. for the. SM-6 Programmable Stereo Mixer

EZ-LIGHT K30L Series With Independent Push Button Contact

For use with QED and hardwired control panels ONLY!

STD-525T PRECISION TIMER

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

FOREST SHUTTLE S / L / M RECEIVER

EZ-LIGHT S18L Color General-Purpose Indicators

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

DIGITAL TIME CLOCK. used with the Meal-Time Control Panel. AGRI-TIME TM Control Instruction Page 1

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

User Manual. VGA to Component or Component to VGA Converter Scaler AT-VGA300CV

LED Series Sealed Backlights

Model R177M and R177S Baseband Switch

VPM2. Operation Manual

Single Station Waterproof Timer

HTP1502W1 Remote Controlled Multicolor Lighting System

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Quick Installation Guide. Indoor / Outdoor Antenna, Antenna Cable & Surge Arrestor

Model Number Structure

VK-P10SE WARRANTY REGISTRATION FORM

STAGE SETTER-8. User Instructions. Elation Professional 4295 Charter Street Los Angeles Ca

Installation and Operation Manual

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

RG NDT INTERNATIONAL INC

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

For warranty service, please contact Microframe at: A technician will gladly assist you.

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

APSPB PUSH BUTTON ZERO Installation Manual

Sphinx II. Owner s Manual. Tube Hybrid Integrated Power Amplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 08/01/16

Operating Manual. Basic Control BC16. two-channel for eco moon

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

Chroma-Q Color Block PSU-30

BENESTON USER MANUAL AHD-ER03H. AHD to HDMI & VGA & AV Converter AHD-ER03H

VPM2. Operator's Manual

Model No. ST100 VTR CONTROLLER

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

MWCS-CC9-MYA MYE 900MHz CableSAT TV Channel Changer

Indoor/Outdoor Security System with Quad Monitor User s Manual

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. June 2015 Part Numbers FIBER DRIVER

TITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT. MATERIAL: White 16lb (60g/m sq), uncoated, prefer recycled stock Ink: Black

3.5 TFT LCD CCTV Service Viewer with Wristband

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

Introduction Congratulations and thank you for purchasing W Box Technologies 0E-HDMISPL2.

16-Channel Headstage Omnetics IFU

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact us. This manual may contain technical or

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

Metal Electrode Meter

LBS-1 (Lowrance Broadband Sounder)

COMPOSITE VIDEO (BNC) TO VGA VIDEO FORMAT CONVERTER AND SCALER AT-RGB110

Information. Marketing Description. For Models: DA2133i. 2113i. User s Guide Rev B

ST-4000D SIGNAL LEVEL METER

User Manual. AtlonA. Passive VGA Extender with Wall Plate or Box options up to 330ft over 1 x CAT5/6/7 Cable AT-VGA100-SR and AT-WPVGA-SR AT-WPVGA-SR

MWCS-AT9-MYA MYE 900MHz (Wireless) CableSAT

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

Tube Roller Shakers. User Guide. Version 1.2

PAD-2 2 Channel A-D Converter Mk2 Rev. 3 Sept. 24, 2017

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

1 x 10 Component Video with Stereo and Digital Audio Distribution Amplifier over CAT5/6 compatible with AT-COMP300RL AT-COMP10SS

Transcription:

Sprite TL Quick Start Guide with 115 VAC Power Cord and 4-Conductor Signal Cable Reference Manual Sprite TL Online and downloadable Product Manuals and Quick Start Guides are available at www.hydrosystemsco.com Please check online for the latest version of this Reference Manual.! WARNING: The Sprite TL Quick Start Guide is intended to be installed by experienced installers, in accordance with all applicable electrical and plumbing codes. All dish machine and dispenser power must be disconnected during installation and/or any time the dispenser cabinet is opened. NOTE: Always use proper lockout tagout procedures when servicing the dispenser. Preface This manual has been written and illustrated to present the basic installation, operation and servicing instructions of the Sprite TL Warewash Dispensing System. Guidelines will be suggested in reference to the preferred method of installation, however, the variety of equipment and the surrounding environment will dictate the actual installation of the Sprite TL. P/N 20-08520-00 Rev. C Hydro Systems Company, Inc. 2015 HydroSystemsCo.com Toll Free: 1.800.543.7184 1

Installation Mechanical Installation NOTE: Choose a suitable mounting location that: (1) Provides the machine operator with access to the dispenser front panel and (2) is within close proximity to the washer and product containers. Unit Mounting! CAUTION: All high voltage wiring must be performed with the cable provided and be enclosed in flexible conduit, seal-tite or other housing approved for damp locations. 1. Mount unit in suitable location with mounting bracket and hardware provided. 2. Discharge tubing: Cut tubing (not provided) to appropriate length and connect from discharge pump (right side) to washing machine inlet port (liquid products). 3. Product intake tubing: Cut tubing (not provided) to appropriate length and connect from intake pump (left side) to product container. Electrical Installation NOTE: The Sprite TL is double-insulated. No earth/ground connection is provided or required. Signal wiring is via one cable that is routed to the signal wiring location in the machine. 115 VAC Plug power cord into 115V outlet. Installation should be performed only by experienced installers in accordance with all applicable electrical and plumbing codes. Disconnect all wash machine and dispenser power during installation or at any time the dispenser cabinet is opened. Always verify all voltage sources with meter. Signal Wiring Input signal wire pairs are optically isolated signal inputs that accept signal voltages ranging from 24-240VAC (or 24VDC). Violet and white/violet = Signal 1 Yellow and white/yellow = Signal 2 Signal wiring only applies to Automatic & Sequence Modes. Signal inputs are ignored in Push-Button Mode. (See USER MODE on page 7 for an explanation of operating modes.) Automatic Mode (AU) Connect violet and white/violet signal wires to supply signal wiring connections for pump 1 (left pump). Connect yellow and white/yellow signal wires to supply signal wiring connections for pump 2 (right pump). Sequence Mode/Occurrence (oc) Connect signal wire pairs to washing machine fill valves (i.e. violet and white/violet to cold fill valve coil and yellow and white/yellow to hot fill valve). P/N 20-08520-00 Rev. C Hydro Systems Company, Inc. 2015 HydroSystemsCo.com Toll Free: 1.800.543.7184 2

Maintenance & Specifications Routine maintenance includes wiping dispenser clean with a damp cloth and periodically replacing Pump Tube. Spare Parts Pump Tube, Detergent, EPDM, (incl. Barb Fittings) 10 pk. 13-07028-10 Pump Front (incl. Captive Screw) 13-06398-00 Pump Spinner 13-06396-00 PC Board (incl. Upper Cabinet Front) 13-06393-110 Power Transformer 13-06394-00 Pump Motor Assembly (left) 13-06523-01 Pump Motor Assembly (right) 13-06524-01 Specifications Size 6" W x 8.875" H x 4.88" D (15.24 cm W x 22.7 cm H x 12.38 cm D) Weight 5.98 lbs. (2.71 kilos) Temperature 120º F Maximum Power 90 to 130 VAC, 50/60 Hz. 0.5 amps (max.) Pump Flow Rate 5.25 oz./minute (156 mls./minute) NOTE: Specifications subject to change without notice. P/N 20-08520-00 Rev. C Hydro Systems Company, Inc. 2015 HydroSystemsCo.com Toll Free: 1.800.543.7184 3

Programming Refer to Programming Menu Screens on page 6 for information on moving through the programming menus. Input Installer Password A password is required for access to programming. The factory pre-set password is 123. To change the password, see Password Edit Pin on page 5. NOTE: You have 10 seconds to input the correct password. An incorrect password returns you to the Home Screen. To input the password: 1. Press and hold ENTER for two seconds to access the Password input screen. 2. Press SCROLL to change the blinking digit to the desired value. Press NEXT to move to the next digit. 3. Repeat for next two digits, then press ENTER when correct password displays. Prime Pump P-1 Press SCROLL to select pump number. Press ENTER to turn pump on. Press ENTER again to turn the pump off. Pump prime is automatically ended after 5 minutes if pump is left on. Clear Load Counter CLr Display toggles every two seconds between CLr and load count (all formulas). Press ENTER to reset. Operating Parameters op Display toggles every two seconds between op and the current selection. Press ENTER to select Au (Automatic), Pb (Push Button), or oc (Occurrence/Sequence) mode of dispenser operation. (See USER MODE on page 7 for information on the three operating modes.) Lockout Period LP Press ENTER to view the lockout period, in minutes. Input is the same as Password input. 000 = Lockout off. NOTE: In Sequence Mode, program the lockout period to be longer than the TOTAL of all programmed pump run and delay times. The lockout period should approximately match the washer cycle time to run a complete load. Formula Program F-1 Press SCROLL to select the formula number (1-4) to program. Press ENTER to move through the Formula Program menu loop (P1, D1, A1, Fin) for that formula. Pump Amount P1A The display toggles every 2 seconds between the stored run time (in seconds) for the selected pump number and Pxx. 1. Press SCROLL to select the desired pump number 2. To set pump run time, press and hold ENTER for two seconds to start pump (display increments in seconds while pump runs). 3. When desired time/volume is reached, press ENTER again to stop the pump and set the value. 4. Repeat for all desired pumps within the current formula selection. Delay Time D1A Press SCROLL to select pump number that needs a delay time, then press ENTER. Input delay time (same input method as Password input), in minutes. P/N 20-08520-00 Rev. C Hydro Systems Company, Inc. 2015 HydroSystemsCo.com Toll Free: 1.800.543.7184 4

Programming Assign Pump A1A (Only active in Sequence Mode.) Assign pump numbers to signal sequence occurrences. 1. Press SCROLL to select pump number, then press ENTER to access occurrence input screen (oc). 2. Press SCROLL to assign the signal occurrence for the previously selected pump number. 3. Press ENTER to return to F-1. Finish Program Fin Press ENTER at this screen to return to the F-1 formula number selection screen in the main menu loop. Filter Duration Fd Press ENTER to set Signal Filter Duration (same input method as Password input) in seconds (0-19, default 3). NOTE: In Sequence Mode, set a Filter Duration time that is long enough to filter out extra fill signals that may occur as the washer calls for more water, etc. Typically, leave at default setting for Automatic Mode. User Prime upr Every two seconds the screen toggles between UPr and current User Prime setting (on or off). Press ENTER to change this setting. Password Edit Pin Choose any three-digit number as a new password. Press SCROLL to change the blinking digit to the desired value. Press NEXT to move the blinking digit. Repeat for all digits. then press ENTER to set the new password. NOTE: Be sure to make note of any password changes! Access to Programming is not available if the password is lost! Exit Program End Press ENTER to exit Programming and return to User Mode. Restore Factory Defaults To clear all values and restore factory settings, press and hold SCROLL for 2 seconds, then press ENTER (while sill pressing SCROLL). FAC displays to indicate that you have restored factory settings and cleared the dispenser s memory (including counter reset to zero). Press ENTER again to return to User Mode. P/N 20-08520-00 Rev. C Hydro Systems Company, Inc. 2015 HydroSystemsCo.com Toll Free: 1.800.543.7184 5

Programming Programming Menu Screens P/N 20-08520-00 Rev. C Hydro Systems Company, Inc. 2015 HydroSystemsCo.com Toll Free: 1.800.543.7184 6

Programming User Mode The Sprite TL dispenser offers three modes of operation: Automatic Mode runs each pump program (program = delay time + run time) once, when it receives a qualified signal to the respective signal input. The Lockout Timer begins when the first pump program starts (start of delay time). During the lockout period, a pump may only run once (regardless of number of signals received). Signal status, lockout status and pumps running display. Sequence/Occurrence Mode is an automatic logic in which signals from input numbers 1 and 2 act as a single-logic input signal. Signal occurrences are counted to determine when each pump runs, based on pumpassignments made in Formula Programming (screen A1A ). Simultaneous input signals count as one signal occurrence. Pump 1 has two programmable amounts, A and B, which are treated as separate programs. Signal status, lockout status and pumps running display. Push Button Mode relies on the user to start the wash formula program. The user selects the formula number, then starts the wash formula program by pressing and releasing ENTER within 2 seconds. Pumps run based on programmed delay and run times. During the lockout time, all start-button presses are ignored (except Password input). Pumps running and lockout status display. NOTE: Password input and User Prime (if enabled) will reset lockout timer and end wash load. User Menu Screens Formula Selection From a Home Screen, press SCROLL to select programmed formulas (1-4). View Load Counter From a Home Screen, press NEXT once to display L. Load counter (all formulas) will toggle between L and load count since Load Counter was last cleared. Prime Pumps (when enabled) 1. From a Home Screen, press NEXT twice to display P1. 2. Press SCROLL to select pump number to prime. 3. Press ENTER to turn selected pump on or off. NOTE: Prime Pumps is only available when unit is not in a lockout timer period. P/N 20-08520-00 Rev. C Hydro Systems Company, Inc. 2015 HydroSystemsCo.com Toll Free: 1.800.543.7184 7

Programming & Warranty Password Access to Programming When Formula Selection displays, press and hold ENTER for 2 seconds. To input password, follow the instructions in Input Installer Password on page 4. Start Formula From a Home Screen, press and release ENTER within 2 seconds to trigger manual dispensing. NOTE: To terminate wash formula before end of lockout period, press and hold ENTER for longer than 2 seconds, release, and wait 10 seconds for screen to revert to Home Screen. Limited Warranty Seller warrants solely to Buyer the Products will be free from defects in material and workmanship under normal use and service for a period of one year from the date of completion of manufacture. This limited warranty does not apply to (a) hoses; (b) and products that have a normal life shorter than one year; or (c) failure in performance or damage caused by chemicals, abrasive materials, corrosion, lightning, improper voltage supply, physical abuse, mishandling or misapplication. In the event the Products are altered or repaired by Buyer without Seller s prior written approval, all warranties will be void. No other warranty, oral, express or implied, including any warranty of merchantablilty or fitness for any particular purpose, is made for these products, and all other warranties are hereby expressly excluded. Seller s sole obligation under this warranty will be, at Seller s option, to repair or replace F.O.B. Seller s facility in Cincinnati, Ohio any Products found to be other than as warranted. Limitation of Liability Seller s warranty obligations and Buyer s remedies are solely and exclusively as stated herein. Seller shall have no other liability, direct or indirect, of any kind, including liability for special, incidental, or consequential damages or for any other claims for damage or loss resulting from any cause whatsoever, whether based on negligence, strict liability, breach of contract or breach of warranty. P/N 20-08520-00 Rev. C Hydro Systems Company, Inc. 2015 HydroSystemsCo.com Toll Free: 1.800.543.7184 8