The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Similar documents
The Haymarket Basingstoke Technical Specifications

The Anvil Technical Specifications

RPAC REDLANDS PERFORMING ARTS CENTRE

Theatre Technical Specifications

Main House Technical Specification

Technical Specification

DEREHAM MEMORIAL HALL

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Dr JOHN GALLAGHER CONCERT CHAMBER

Theatre Technical Specification

Matt Dann Cultural Centre

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

New Theatre Royal Lincoln Technical Information

2017 TECHNICAL SPECIFICATIONS

Technical Specifications Nov 2016

CHELSEA THEATRE. Technical Specifications

Technical Specification

TECHNICAL SPECIFICATIONS

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Specifications

UNIVERSITY CONCERT HALL. Technical Specification

JERWOOD VANBRUGH THEATRE

Technical Specification. Updated: April 2016

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

INFORMATION FOR VISITING COMPANIES

TECHNICAL SPECIFICATION

Technical Specification for the Alley Theatre, Strabane

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

ISLAND HALL TECHNICAL INFORMATION

Arlington Arts Tech Spec 2018

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Main House Technical Specifications

Pleasance London Main House Visiting Company Information Pack May 2017

Latrobe Performing Arts Centre

Cornerstone Technical Specifications 2018 / V1

Technical Specifications

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

MONASH University Academy of Performing Arts

Darlington Hippodrome Technical Specification

Stage. Get In & Parking

Technical Director of Production Andrew Quick Ext 252

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Theatre Technical Specifications

Esso BHP Billiton Wellington Entertainment Centre

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Technical Pack. Attenborough Arts Centre

Concert Hall Technical Specifications

John Leslie Theatre. Technical Specifications. Updated July 2018

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Specification Ardhowen Theatre

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Concert Hall Technical Specifications

Technical specifications Main theatre. Sound

Technical Specification Pavilion Dance

Summary. Access and Parking

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Technical Information

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Shouson Theatre Venue Specifications (updated Jan 2017)

HIRE AND TECHNICAL INFORMATION

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Technical Specifications and Inventory Spring 2018

MAIN THEATRE TECHNICAL SPECIFICATION

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Backstage Accommodation (Ground Floor Mezzanine Level 1 Floor above Loading Bay)

THE STREET THEATRE. Technical Specifications

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Specification

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Anvil Theatre. Technical Information

Yan Yean Theatre Technical Specifications

Technical Data Sheet

TECHNICAL SPECIFICATIONS

There are 10 dressing rooms in Theatre Kerkrade.

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Access to back stage is off Fletcher St on the eastern side of the building

Hopgood Theatre NOARLUNGA CENTRE

Compass Theatre - Technical Information Pack

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

SHUBERT THEATER 247 College Street, New Haven, CT

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

Technical Specifications

CENTRE FOR PERFORMING ARTS

Technical Information

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

Technical Services and Specification

Queensland Performing Arts Centre

Transcription:

The Haymarket Technical Specifications The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW Head of Production E: ruairi.mcnulty@anvilarts.org.uk T: 01256 819797 Ext: 118 Production and E: amanda.wise@anvilarts.org.uk Facilities Administrator T: 01256 819797 Ext: 164 Programme Assistant E: annalee.mcgarry@anvilarts.org.uk T: 01256 819797 Ext: 108 Please note the equipment listed here may not always be available, please check with the Production Department. Updated November 2017 Page 1

MAIN HOUSE STAGE / FLYING Stage plan: See Appendix A Staging: Proscenium Opening Stage Depth Setting line to Back Wall Setting Line to Edge of stage Setting Line to Edge of Forestage/Pit Lift Depth of Forestage/Pit lift Height of stage from Stalls Level Height to Underside of Fly Floor Height to Underside of Pulleys @ Grid Width between Fly Floors 8970mm (w) x 5000 mm (h) 8030mm at Centre Line 1450mm 3100mm 1640mm 940mm 6350mm 10230mm 10400mm LX bars distances from the setting line: LX1: 600mm LX2: 2200mm LX3: 3800mm LX4: 5600mm LX5/Flood bar: 6200mm Backdrop: 7200mm Flying: Hemp Sets 29 Winches 5 Advance FOH Winch Truss 1 Bar Width 10000mm SWL: Hemps 110.00Kg UDL / 55Kg PL Winches 300.00Kg UDL / 60Kg PL House Curtain 175.00Kg UDL FOH Truss 500.00Kg UDL (UDL = Uniformly Distributed Load / PL = Point Load) Updated November 2017 Page 2

GET IN Access to stage is not level and requires either the use of the auditorium pit lift or winch system at the dock door. The Dock door is +4200mm above ground level and all items must be winched in from ground level by a single pickup motor hoist. Max Dimensions for Get Ins: Via Dock door @ +4200mm (h) 2.5M x 5.3M Via Stage Door/Pit Lift 2.4M Diagonal POWER SUPPLIES DSR / Scenery Dock 1x 63A 3 Phase / 1x 63A Single / 1x 32A Single / 2x 16A Single DSL 1x 32A Single Phase Audio Power / Clean Supply A selection of domestic 13 amp sockets are available around the stage and auditorium 24x 15A Non-Dim circuits Stage Manager s desk situated DSR comprising: COMMUNICATIONS Cue Lights control station Infrared stage video monitor Show timer FOH and Backstage Paging A belt pack and headset intercom attached to the desk Intercom comprising: 10 x 1 channel belt packs and headsets 9 x Cue lights Additional communications including: 2 channel IR audio descriptive system Video and audio show relay Video and audio patch running to various points round the building Updated November 2017 Page 3

DRESSING ROOM FACILITIES 2 x en-suite dressing rooms suitable for 1 or 2 performers ( D & C ) 2 x Large Chorus dressing rooms suitable for a maximum of 20 performers each 1 x Dressing room suitable for up to 4 people ( B ) 1 x Dressing Room suitable for 4 people / Visiting Company Managers Room ( A ) 1 x Additional Performer Storage Room 1 x Laundry room Each dressing room has a safe for personal possessions There are 5 toilets which are used by staff and performers Dressing Dressing Chorus Chorus Stairs to SL Room D Room C Dressing Room 1 Dressing Room 2 Sound Kitchen Store Toilet Showers & Toilets Toilets Dressing Room B Stairs to SR Stage Door Under Stage Crossover & entrance to orchestra pit Orchestra Pit Pit Store Laundry room LX Store Crew Room Storage Dressing Room A Updated November 2017 Page 4

AUDITORIUM MIXER POSITIONS The House mixer position is located at the rear of the Stalls. The Mixer Position can be moved to the control box at the rear of the circle or be operated from the side of stage. Tie lines around the stage and auditorium allow you to patch into the house system from a variety of locations. View from Control Room Position View from Stalls Mixer Position Updated November 2017 Page 5

FORMATS The Auditorium Pit Elevator can be used in 3 positions. 1. At stage level to create a stage extension 2. At Auditorium level (usual position) 3. At Orchestral Pit Level Updated November 2017 Page 6

ORCHESTRA PIT An orchestra pit is available in some formats. 13A Power is available in the Orchestra pit. 12 Music stands with lights are available for use in the pit and 1 lit conductor s music stand. Please see Appendix A for a section showing pit positions. STAGE EQUIPMENT AND MASKING A selection of hard masking flats is available to create a variety of formats. To supplement this, the following are also available: 1 x Full White Cyclorama 1 x Full Blacks (2 Pieces) permanently rigged 1 x Tab Swipe Track 1 x Curtain Track 1 x Red House Curtain (permanently rigged) 2 x Book flats for onstage quick change areas 2 x Treads for auditorium/stage access 2 x 8 x 4 Lite Deck at 1 Height 1 x Full black Gauze 1 x White Gauze 1 x Set of Thin Black Blinders in 2 parts 1 x Set of Blacks Dip Traps run the depth of the stage at either side and underneath the Iron. These can be seen on the plans in Appendix A Black Harlequin dance floor is available to cover the entire stage on request. Updated November 2017 Page 7

LIGHTING Control: ETC Ion Lighting Control Desk; 2x DMX Outputs, 512 Ch; 999 Cue Lists; 200 Active Playbacks / Universal Fader Wing with 2 rows of 20 Faders Dimmers: Lanterns: 205 way ETC Sensor. 20 Non Dim Circuits Availability on lanterns varies due to an ongoing maintenance schedule. Please confirm availability when submitting a lighting plan. The current full lantern stock is listed below: Lanterns Stock: 30 Par Cans 13 Floor Cans (7 black and 6 silver) 45 Selecon Rama 150 Fresnel 1.2k 2 Selecon 2.5k Arena Theatre Fresnel 13 ETC Source 4 with 19/26/36 degree lens tubes and one 50 degree. 12 ETC Source 4 Zoom (permanently rigged on the FOH Bridge) 25 ETC Source 4 Zoom Jnr (25 to 50 degree lens) 16 Coda 1K 1 Source 4 Jnr 6 3 channel Flood Battens 12 Birdies Gobo holders and Irises are available for the majority of lanterns. Please contact the Production Department for advice on availability. Updated November 2017 Page 8

SOUND Mix Position: There are two available mix positions for FOH. One is sited at the rear of the stalls underneath the circle balcony. This position is suitable for larger consoles and has a clear view of the stage. Only 13a power is available at this mixing position. No seating requires removing to use this position. N.B Visiting companies please be aware; this mix position can accommodate most consoles. However some larger consoles will not fit due to space restrictions. The second is located inside the control room. There is a sliding glass window which can moved to allow a clear listening position of the P.A. This position is not suitable for large or digital consoles due to restricted space and no multicore run. Only 13a power is available at this mixing position. Tie lines around located around the stage and auditorium allowing you to patch into the house system from a variety of locations. Mixing Desks: Midas M32 Digital The Midas M32 is our permanent FOH console. It can be removed if needed so please advise if you require this. Visiting companies please be aware, this mix position can accommodate most consoles. However some larger consoles will not fit due to space restrictions. 40 Inputs: 32 XLR 6 1/4 Jack Stereo RCA 1 Talkback Mic Input 22 Outputs: 16 Freely assignable XLR 2 Monitor XLR 2 Monitor 1/4 Jack 2 1/4 RCA 4 Band EQ on each input channel 25 Time aligned and Phase Coherent Mix buses 6 mute groups 8 stereo signal processing effect engines including boutique EQ and compressors 7 TFT Display Auto-ranging universal switch mode power supply 32x32 USB audio interface Updated November 2017 Page 9

Digital Stage Boxes 2 x Midas DL16 stage boxes. 16 Input 8 output. Allen & Heath MixWizard WZ3 16:2 16 mic / line inputs Mono fader feeds Mono XLR output 6 Auxiliary Sends 4 Band EQ Plus HPF 2 Stereo Returns On-Board Digital FX P.A System P.A system built around a ground stacked EM Acoustics system. This is supplemented with various delays around the auditorium for extra stalls and circle coverage. Stalls Level Stereo PA 2 x EMS 152 Full Range 2 x EMS 81 in fills 2 x i12 ULF subwoofer 2 x EMS 215 subwoofer 1 x EMS 81x Stalls centre fill mounted above proscenium Circle Level Stereo PA 2 x EMS 122 Full Range Extras 2 x EMS 61 can be mounted on rear of lighting bridge for extra circle coverage Processing 1 x XTA DP 448- Main PA and Delays 1 x XTA DP 424- Subwoofers N.B The P.A system has been installed and set up by the manufacturer, and as such the settings of our processors cannot be changed. Updated November 2017 Page 10

Amplifiers 3 x Full Fat Audio 6000 Amplifiers EMS 152 full range i-12 subwoofer EMS 215 1x FFA 4004 amplifier EMS 61 EMS 81 1 x FFA 6004 amplifier EMS 122 EMS 81x (prosc fill) EMS 81 (stalls in-fill) 2 x FFA 6004 amplifier 8 channels of amplification for on stage monitoring Monitor Speakers 6 x EM Acoustics M10 floor monitors 2 x EV SX 200 speakers (plus 2 stands) Multicores 32/4 analogue multicore installed running to stage left from stalls mixer position Cat5e UTP multicore reel 50m can either run to Stage left (preferred) or stage right 12 Channel XLR Satellite box 1 x 12 Channel Return cable. (Used for L, R, Mono, Monitors) 2 x 12 Channel Send cable Playback 2 x Denon CD player 2 x Tascam Minidisk player 1 x Apple Mac pro with Qlab 3 Headphones 1 x Beyerdynamic DT100 1 x AKG K55 Updated November 2017 Page 11

Power Downstage left 1 x 32a single phase audio power Selection of 32a to 16a step down distribution boxes Selection of 16a to 13a step down distribution boxes Selection of 32a and 16a cable. Selection of 13a extensions A good selection of microphones, cables, D.I boxes, adaptors, stands and other equipment is available. Please contact the Production Department in advance if you require any specific details of our stock. Projector/Lens/Rigging: Panasonic PT-DZ13KEJ projector Panasonic ET-D75LE06 0.9-1.1:1 lens Panasonic ET-RFD91 projector cradle KPM flying bracket Cabling / Distribution: DATA PROJECTOR AND SCREEN 1x CYP PU-507TX-1H 1:1 HDBaseT HDMI/LAN/IR/RS-232/PoE Twisted Pair Transmitter with HDMI Loop (Max. 100m at 1080p or 4K;1 x HDMI input; 1 x HDBaseT, 1 x HDMI output) 1x 45m run of Kramer C-HDK6/HDK6-150 RJ-45 Four-Pair U/FTP Cable (23AWG) Optimized for HDBaseT 1x 4.6 m Kramer C-DPM/HM-15 DisplayPort to HDMI (M-M) Assorted VGA runs (50m) 1x Roland V-4EX Vision Mixer Screen: Stumpfl Monoblox 64 Front / Rear Projection Screen & Frame (16 x 9 / 5m x 3.8m) Please contact the Production Department to check availability. Updated November 2017 Page 12

Appendix A Updated November 2017 Page 13

Updated November 2017 Page 14

Updated November 2017 Page 15

Updated November 2017 Page 16