The Haymarket Basingstoke Technical Specifications

Similar documents
The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

The Anvil Technical Specifications

Main House Technical Specification

DEREHAM MEMORIAL HALL

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Theatre Technical Specification

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Dr JOHN GALLAGHER CONCERT CHAMBER

Matt Dann Cultural Centre

CHELSEA THEATRE. Technical Specifications

TECHNICAL SPECIFICATION

Technical Specification

Technical Specifications

INFORMATION FOR VISITING COMPANIES

Technical Specifications Nov 2016

Theatre Technical Specifications

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

RPAC REDLANDS PERFORMING ARTS CENTRE

Technical Specification for the Alley Theatre, Strabane

TECHNICAL SPECIFICATIONS

Technical Services and Specification

Technical Specification. Updated: April 2016

Technical Specifications

JERWOOD VANBRUGH THEATRE

UNIVERSITY CONCERT HALL. Technical Specification

Latrobe Performing Arts Centre

Technical Specification

2017 TECHNICAL SPECIFICATIONS

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Darlington Hippodrome Technical Specification

Concert Hall Technical Specifications

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Cornerstone Technical Specifications 2018 / V1

Pleasance London Main House Visiting Company Information Pack May 2017

Summary. Access and Parking

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Lighthouse Theatre Technical Specification

THE STREET THEATRE. Technical Specifications

New Theatre Royal Lincoln Technical Information

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Technical Specification Ardhowen Theatre

Technical specifications Main theatre. Sound

Technical Director of Production Andrew Quick Ext 252

Concert Hall Technical Specifications

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

HIRE AND TECHNICAL INFORMATION

Sandusky State Theatre Technical Specifications

Technical Information

Access to back stage is off Fletcher St on the eastern side of the building

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Technical Specification Pavilion Dance

Stage. Get In & Parking

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Technical Specifications

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Pack. Attenborough Arts Centre

TECHNICAL SPECIFICATIONS

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Technical Specifications

Dugdale Centre Technical Specification

Hopgood Theatre NOARLUNGA CENTRE

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

Main House Technical Specifications

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Esso BHP Billiton Wellington Entertainment Centre

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Technical Information

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

ISLAND HALL TECHNICAL INFORMATION

Technical Information

Arlington Arts Tech Spec 2018

Technical Information

MAIN THEATRE TECHNICAL SPECIFICATION

John Leslie Theatre. Technical Specifications. Updated July 2018

Backstage Accommodation (Ground Floor Mezzanine Level 1 Floor above Loading Bay)

Patriots Theater at the War Memorial Technical Data

Technical Specifications

Theatre Technical Specifications

SHUBERT THEATER 247 College Street, New Haven, CT

TECHNICAL PACKAGE.

The Lights Technical Guide June 2017

Queensland Performing Arts Centre

Technical Data Sheet

Technical Specifications. Taylor Little Theater

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

Transcription:

The Haymarket Basingstoke Technical Specifications The Haymarket Wote Street Basingstoke Hampshire RG21 7NW 01256 819797 Administration 01256 844244 Box office 01256 331733 Fax For further information please contact Technical Services or a member of the technical staff on the admin number above. UPDATED October 2012 Please note the equipment listed here may not always be available, please check with Technical Services

MAIN HOUSE STAGE/FLYING. Stage plan: See Appendix A Staging: Proscenium Opening 8970mm (w) X 5000 mm (h) Stage Depth Setting line to Back Wall 8030mm at Centre Line Setting Line to Edge of stage 1450mm Setting Line to Edge of Forestage/Pit Lift 3100mm Depth of Forestage/Pitlift 1640mm Height of stage from Stalls Level 940mm Height to Underside of Fly Floor 6350mm Height to Underside of Pulleys @ Grid 10230mm Width Between Fly Floors 10400mm Flying: Hemp Sets 29 Winches 5 Advance FOH Winch Truss 1 Bar Width 10000mm SWL: Hemps 187.50Kg Winches 300.00Kg House Curtain 175.00Kg FOH Truss 500.00Kg GET IN Access to stage in not level and requires either the use for the auditorium pit lift or winch system at the dock door. The Dock door is at +4200mm from ground level and all items must be winched in from ground level by a single pickup motor hoist. Max Dimensions for Get Ins: via Dock door @ +4200mm (h) 2.5M x 5.3M Via Stage Door/Pit Lift 2.4M Diagonal POWER SUPPLIES 32amp single Phase Clean Supply Down Stage Left Selections of 13 amp supplies are available around the stage and auditorium along with 24 Non-Dim circuits. Stage Manager s desk situated DSR comprising. COMMUNICATIONS Cue Lights Low light stage video monitor Intercom FOH and Backstage Paging Intercom comprising. 6x 6x 10x 1 channel belt packs headsets Cue lights Technical Specification 2 of 12

Additional communications including. 2 channel infra red audio descriptive system Video show relay Video and audio patch running to various points round the building. DRESSING ROOM FACILITIES 2 Ensuite dressing rooms suitable for 1 or 2 performers 2 Large Chorus dressing rooms suitable for a maximum of 20 performers each 1 Additional dressing room suitable for up to 4 people Each dressing room has a safe for personal possessions. There are 4 toilets which are used by staff and performers. A large green room/staff room is usually available This area is for use by visiting company and house crew and is not to be used as a dressing room. It may be used for storage by prior arrangement. A Backstage Layout Is below Dressing Room D Dressing Room C Chorus Dressing Room 1 Chorus Dressing Room 2 Stairs to Stage left Stairs to Stage Right Toilets Toilets Showers Under stage Crossover & Entrance to Orchestra Pit Dressing Room B Orchestra Pit Kitchen To Stage Door Store Green Room Technical Specification 3 of 12

AUDITORIUM Mixer positions: The house mixer position is located at the rear of the Stalls. The Mixer Position can be moved to the control box at the rear of the circle or be operated from side of stage. Tie lines around the stage and auditorium can allow you to patch into house system from most locations View from Control Room Position View From Stalls Mixer Position Formats: The auditorium Pit Elevator can be used in 3 positions. 1. At stage level to create a stage extension 2. At Auditorium level (usual position) 3. At Orchestral Pit Level Technical Specification 4 of 12

Technical Specification 5 of 12

ORCHESTRA PIT An orchestra pit is available in some formats but please be aware that this requires the removal of some seating. Power is available in the Orchestra pit. 10 RAT stand are available for use in the pit and 1 lit conductors music stand. Please see Appendix A for a section showing pit positions. STAGE EQUIPMENT AND MASKING A selection of hard masking flats are available to create a variety of formats. 1 x Full White Cyclorama 1 x Full Blacks (2 Pieces) 1 x Tab Swipe Track with Blacks 1 x House Curtain (permanently rigged) 2 x Book flats for onstage quick change areas 2 x Treds for auditorium/stage access Dip Traps run the depth of the stage ate either side and underneath the Iron. These can be seen on the plans in Appendix A Harlequin dance floor available to cover entire stage on request. LIGHTING Control: Dimmers: Lanterns: STRAND 550i 250 CHANNELS; DMX 512 and D54 OUTPUTS;; GENIUS PRO VER 2.6e; TRACKER MOVING LIGHT CONTROL SOFTWARE 205 way ETC Sensor. 24 Non Dim Circuits Availability on lanterns varies due to ongoing maintenance schedule please confirm availability when submitting a lighting plan. The current full lantern stock is listed below 12 6-way IWB's (LectriFlex connectors) Gobo holders available for the majority of lanterns please check availability Please contact technical department for advice on availability. Lanterns: 24 Par Cans 6 Floor Cans 46 Selecon Rama 150 Fresnel 1.2k 2 Selecon 2.5k Arena Theatre Fresnel 2 Selecon Pacific 8 ETC Source 4 12 ETC Source 4 Zoom 25 ETC Source 4 Zoom Jnr 13 Coda 1K 1 Source 4 Jnr 5 3 channel Flood Battens 12 Birdies Technical Specification 6 of 12

SOUND Mixing Desks Soundcraft GB8 32 Channel Console High performance 4-band GB30 EQ 4 stereo inputs handle mic or line inputs with 48V and mic amps on each input 11 true busses including 8 subgroups, left, right and center 8 auxiliary sends with flexible pre/post switching 4 mute groups 11 x 4 matrix allows 4 separate sub-mixes of left, right, center and group outputs Internal power supply WITH external PSU link option! Direct outputs on every mono channel New True VU overbridge monitors left, right and center plus 4 segment LED s on each input and 12 segment output meters Allen & Heath MixWizard WZ 3 16:2 Mono Inputs: 8 or 16 mic / line channels. Mono fader feeds mono XLR output. 6 Auxiliary Sends. 4 Band EQ plus HPF. 2 Stereo Returns. On-board Digital FX. Our mixing position it sited at the rear of the stalls underneath the circle balcony. EM Acoustics PA System: 2 EMS-152 Full Range, Stalls Level 2 EMS-81 Front Fills, Stalls Level 1 EMS-81X Centre Fill mounted on top of Prosc 2 I-12 ULF Subwoofer, Stalls Level 2 EMS-215 Subwoofer, Stalls Level 2 EMS-122 Full Range, Circle Level 2 EMS-61 Circle Delays, Mounted on Back of Lighting Bridge PA Amplifiers and Processing: 1 XTA DP - 448 Main PA and Delays 1 XTA DP 424 Sub 3 FFA 6000 Amplifiers EMS 152 I-12 EMS 215 1 FFA 4004 Amplifier - EMS 81(Bridge Delay) EMS 61 1 FFA 6004 Amplifier EMS 122 EMS 81X (Prosc) EMS 81 (Front Fill) 2 FFA 6004 Amplifiers 8 Channels of Amplification for on stage monitoring Technical Specification 7 of 12

Monitor Speakers: 6 EM Acoustics M-10 Floor Monitors 4 EV S-200 Monitor Speakers 2 JBL Control 5 4 JBL Control 1 2 EV SX 200 Speakers (plus 2 stands) 2 Portable Pro Sound P.A. System Cables and Snakes 1 32/4 Audio Snake 50m Installed 3 12 Channel Stage Box 3 12 Channel Audio Sends Cable 1 12 Channel Audio Returns Cable 3 Harting Cable Outboard 2 Tascam MD player 2 Denon CD player 1 DBX AFS-224 Advanced Feedback Suppressor 1 Alesis 3630 Compressor 2 Samson D2500 DUAL GRAPHIC Digital EQ 1 Yamaha REV500 FX Unit 1 Tascam SS-R! Flash Card Player Phones 1 x DT100 Headphones 1 x AKG K55 Headphones Instruments + Mic stands 2 Fender Acoustic Guitar (+ 2 x hard case and 2 x Stands) 1 Yamaha Electronic Keyboard (+ 1 x case and stand) 1 LEDJ DJ Starcloth 15 Standard Mic Stands 4 Short Mic Stands A good selection of Microphones, DI boxes, cables, adaptors plus other sound equipment is available. Please check in advance if you require specific details to our stock. Technical Specification 8 of 12

Appendix A

Technical Specification 10 of 12

Technical Specification 11 of 12

Technical Specification 12 of 12