File E Vol 1 Auth. Page 1 Issued: Revised: FOLLOW-UP SERVICE PROCEDURE (TYPE R)

Similar documents

Furnish and Deliver New Light Emitting Diode (LED) Fluorescent Light Tubes

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

Test specification: Test procedures:... ErP Commission Regulation (EU) No. 1194/2012 implementing Directive 2009/125/EC the European Parliament and

American National Standard for Electric Lamps Double-Capped Fluorescent Lamps Dimensional and Electrical Characteristics

FLUID VIEW 12V LED TAPE LIGHT

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

SubstiTUBE Value EM Fighter Tube Technical Datasheet

MATERIAL SPECIFICATION FOR SIGNAL HEADS

COVER PAGE FOR TEST REPORT

2-Piece LED Emergency Back-Up and Kits

Philips Corepro LEDtube T8

Philips InstantFit LED PL-C/T Lamp

Illustrated Feature. Options

Commercial Lighting Program TECHNICAL SPECIFICATION GUIDE. *Manitoba Hydro is a licensee of the Trademark and Official Mark.

LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances

1. Product Name. 2. Product Code. 3. Colour. 4. Brief Description. 5. Contents. Wi Fi Mood Lighting. As supplied

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

Model Number Structure

EnabLED Licensing Program for LED Luminaires and Retrofit Bulbs

User Manual. Model 979T and 979R Digital Audio Converters

EXLUX ECOLUX C-LUX 6480 Series

Features. Typical Applications

Warner Photoscanner MCS-500 Series LED Photoelectric Control

COVER PAGE FOR TEST REPORT

FKSZ2.E Drivers for Light-emitting-diode Arrays, Modules and Controllers -...

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations

EXLUX ECOLUX 6480 Series

Instant 802.3af Gigabit Outdoor PoE Converter. Model: INS-3AF-O-G. Quick Start Guide

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

American National Standard for Electric Lamps - Fluorescent Lamps - Guide for Electrical Measures

SQM40/41 Actuators for air and gas dampers

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

Pauluhn Apex. Linear, high bay LED luminaires designed for harsh & heavy industrial applications

ercial the Features Product connectivity

XML LED X M L L E D. Explosionproof Linear LED Lighting

Features. High Brightness SMD LED Light source

FKSZ8.E Drivers for Light-emitting-diode Arrays, Modules and Controllers Cert...

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Photovoltaic Module Installation Manual (IEC)

Seattle IFMA Education Symposium June The Riddles of LED Lighting. Chris Lewis, CFM

SC-C1M SiriusConnect TM Vehicle Tuner

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Protect Your Hearing!

Safety Codes Council Conference Banff C Panel Discussion

Operating instructions

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Surface Mount Multilayer Ceramic Chip Capacitors for High Temperatures 200 C

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

AY-U910 UHF Integrated Long-Range Reader Installation and User Manual

RKDISE LED. LED Center Basket Retrofit Kit EXAMPLE: RKDISE24-LED48FRDMV WATT CAT# APPLICATIONS FEATURES & BENEFITS

Photovoltaic Module Installation Manual (IEC)

NS-3 RF Noise Source Operation Manual

Model 1421 Distribution Amplifier

Winch Adjustable Feed Level Tubes for the Adult Turkey Feeder Installation & Operator s Instruction Manual MF /99

AC Line Rated Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

Procedure And/Or Report Material

Solutions for Electronic Specialty Markets (ESM)

American National Standard for Lamp Ballasts High Frequency Fluorescent Lamp Ballasts

T8 LED Tube. UL-Lighting. Features. Certificates. Web:

CHALICE PENDANT LED DOWNLIGHT 70 Watt LED

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

LED MODULES READYLINE DL

LED SUPERSTAR CLASSIC A 60 DIM 9 W/827 E27 FR

24 Volt RGB/RGA Super Flat LED Rope Part Numbers: SFR-RGB-W, SFR-RGB-B, SFR-RGA-W, SFR-RGA-B

NSR0130P2. Schottky Barrier Diode 30 V SCHOTTKY BARRIER DIODE

Operating Instructions Dimmer for V Incandescent Lamps

QTi DALI 2X14/24/ DIM

Caveled Tunnel Lighting Series. SL-Caveled/100277AC (UL) - B Type - UL certified (E326344) Features. Typical Applications.

Flexible Filament Bulb ST64_4W Golden Datasheet

NEW! Wide Area Lighting - Rough Service Fluorescent. MULTIVOLTAGE Automatically Operates at 120 to 277 VAC 50 or 60 Hz *1142 only

In the center we ve got 2 views of a typical 2 foot by 4 foot fluorescent light fixture, or ceiling troffer. The upper photo shows it in the ceiling,

Scotch Heavy Duty Vinyl Electrical Tape 22

HYDROLUME LED STRIP LIGHT

Instructions. P MHz 1X/10X Passive Probe

Colour Explosion Proof Video Camera USER MANUAL VID-C

Installation Manual for New or Retrofit Installations

Axial Fan, 4 in, Bulletin D85 (Hoffman Thermal Management

BROADCAST RECEIVER. Installation Guide (BR-100-MOT, BRP-100-MOT) Document Version 1.0. BR-100-MOT, BRP-100-MOT Installation Guide

CLD Series. CLD LED Surface Luminaire

Power Injector 1520 Series

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

User Guide. HDMI Fiber Optic Extender. DVI-7350a

American Power Design, Inc.

Operation Manual VMS 3.0 Video System

AYCL253PBR Ariadni 250W Led 3WAY Dimmer Brown

Surface Mount Multilayer Ceramic Chip Capacitors for High Frequency

American National Standard for Electric Lamps Specifications for the Chromaticity of Solid-state Lighting Products

Indoor/Outdoor Security System with Quad Monitor User s Manual

General purpose low noise wideband amplifier for frequencies between DC and 2.2 GHz

IK10 IP68. Specifications. White (4 300 K typical) Warm white (3 000 K typical) Blue (470 nm) Other colors by request

ROAD COMMISSION FOR OAKLAND COUNTY SPECIAL PROVISION FOR LIGHT EMITTING DIODE (LED) VEHICLE TRAFFIC SIGNALS

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

QTi 2X28/54 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DIM T5 ECG dimmable 1 10 V for FL 16 mm. Areas of application.

General purpose low noise wideband amplifier for frequencies between DC and 750 MHz

Transcription:

File E358903 Vol 1 Auth. Page 1 Issued: 2012-10-30 Revised: 2012-10-30 FOLLOW-UP SERVICE PROCEDURE (TYPE R) LIGHT-EMITTING-DIODE RETROFIT LUMINAIRE CONVERSION KITS (IFAR,IFAR7) Manufacturer: SEE ADDENDUM FOR MANUFACTURER LOCATIONS 2776712 (Party Site) Applicant: JAMES INDUSTRY GROUP CO LTD (100591-493) R1205(S01), 12/FL TAI SANG BANK BLDG 130-132 DES VOEUX RD CENTRAL HONG KONG Listee/Classified Co.: (100591-493) 2776712 (Party Site) SAME AS APPLICANT This Follow-Up Service Procedure authorizes the above Manufacturer(s) to use the marking specified by UL LLC, or any authorized licensee of UL LLC, including the UL Contracting Party, only on products when constructed, tested and found to be in compliance with the requirements of this Follow-Up Service Procedure and in accordance with the terms of the applicable service agreement with UL Contracting Party and any applicable Service Terms. The UL Contracting Party for Follow-Up Services is listed on addendum to this Follow-Up Service Procedure ("UL Contracting Party"). UL Contracting Party and UL LLC are referred to jointly herein as "UL." UL further defines responsibilities, duties and requirements for both Manufacturers and UL representatives in the document titled, "UL Mark Surveillance Requirements" that can be located at the following web-site: http://www.ul.com/fus and in the document titled "UL and Subscriber Responsibilities" that can be located at the following website: http://www.ul.com/responsibilities. Manufacturers without Internet access may obtain the current version of these documents from their local UL customer service representative or UL field representative. For assistance, or to obtain a paper copy of these documents or the applicable Service Terms, please contact UL's Customer Service at http://www.ul.com/global/eng/pages/corporate/contactus, select a location and enter your request, or call the number listed for that location. The Applicant, the specified Manufacturer(s) and any Listee/Classified Co. in this Follow-Up Service Procedure must agree to receive Follow-Up Services from UL Contracting Party. If your applicable agreement is a Global Services Agreement ("GSA") with an effective date of January 1, 2012 or later and this Follow-Up Service Procedure is issued on or after that effective date, the Applicant, the specified Manufacturer(s) and any Listee/Classified Co. will be bound to a Service Agreement for Follow-Up Services upon the earliest by any Subscriber of use of the prescribed UL Mark, acceptance of the factory inspection, or payment of the Follow-Up Service fees which will incorporate such GSA, this Follow-Up Service Procedure and the Follow-Up Service Terms which can be accessed by clicking here: http://www.ul.com/contracts/terms-after-12-31-2011. In all other events, Follow-Up Services will be governed by and incorporate the terms of your applicable service agreement and this Follow-Up Service Procedure.

File E358903 Vol 1 Auth. Page 2 Issued: 2012-10-30 Revised: 2012-10-30 It is the responsibility of the Listee/Classified Co. to make sure that only the products meeting the aforementioned requirements bear the authorized Marks of UL LLC, or any authorized licensee of UL LLC. This Follow-Up Service Procedure contains information for the use of the above Manufacturer(s) and representatives of UL and is not to be used for any other purpose. It is provided to the Manufacturer with the understanding that it will be returned upon request and is not to be copied in whole or in part. This Follow-Up Service Procedure, and any subsequent revisions, is the property of UL and is not transferable. This Follow-Up Service Procedure contains confidential information for use only by the above named Manufacturer(s) and representatives of UL and is not to be used for any other purpose. It is provided to the Subscribers with the understanding that it is not to be copied, either wholly or in part unless specifically allowed, and that it will be returned to UL, upon request. Capitalized terms used but not defined herein have the meanings set forth in the GSA and the applicable Service Terms or any other applicable UL service agreement. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental, consequential or punitive damages arising out of or in connection with the use or reliance upon this Follow-Up Service Procedure to anyone other than the above Manufacturer(s) as provided in the agreement between UL LLC or an authorized licensee of UL LLC, including UL Contracting Party, and the Manufacturer(s). UL LLC has signed below solely in its capacity as the accredited entity to indicate that this Follow-Up Service Procedure is in compliance with the accreditation requirements. William R. Carney Director North American Certification Program

File E358903 Vol 1 Addendum To Page 1 Issued: 2012-10-30 Authorization Page Revised: 2012-10-30 LOCATION 2417736 (Party Site) (100554-437) SHENZHEN BESON TECHNOLOGY CO LTD BESON TECH PARK NO 22 DONGFANG ROAD SONGGANG TOWN, BAOAN DISTRICT SHENZHEN GUANGDONG 518105 CHINA Factory ID: None UL Contracting Party for above site is: UL AG

File E358903 Vol. 1 IFAR Page 1 Issued: 2011-04-11 Classification Mark Data Page COMPOSITION AND ELEMENT (FILE IMMEDIATELY AFTER AUTHORIZATION PAGE) CLASSIFICATION MARK The Classification Mark shall consist of the following and shall appear on the product. LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH (+) IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT 4YP5 (+) PERMANENTLY-CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s) MARKING or LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT 4YP5 The following symbol shall be located adjacent to or in close proximity to the regular Classification Mark as shown above. The minimum height of the registered trademark symbol shall be 3/64 of an inch. When the overall diameter of the UL Mark is less than 3/8 of an inch, the trademark symbol may be omitted if it is not legible. Camera-ready artwork and relative proportions are available online at www.ul.com. PROCUREMENT The manufacturer may reproduce the Mark or obtain it from an authorized label supplier. Authorized label suppliers can be found online at www.ul.com. THIS PAGE SHALL BE REVISED BY UL LABEL OPERATIONS ONLY

File E358903 Vol. 1 IFAR7 Page 1 of 2 Issued: 2011-04-11 Canadian Classification Mark Data Page COMPOSITION AND ELEMENT (FILE IMMEDIATELY AFTER AUTHORIZATION PAGE) CLASSIFICATION MARK The Canadian Classification Mark shall consist of the following and shall appear on the product. LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH (+) IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT 4YP5 (+) PERMANENTLY-CONNECTED LUMINAIRES, FLUORESCENT LUMINAIRES, INCANDESCENT LUMINAIRES, HID LUMINAIRES, OFFICE-FURNISHING LIGHTS and/or PORTABLE LUMINAIRES; or indicate the specific luminaire model(s) and luminaire manufacturer(s) MARKING or LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT 4YP5 The following symbols shall be located adjacent to or in close proximity to the regular Classification Mark as shown above. The Canadian/US symbol shall be used if both Canadian and US coverage is authorized: The Canadian symbol shall be used if only Canadian coverage is authorized: THIS PAGE SHALL BE REVISED BY UL LABEL OPERATIONS ONLY

File E358903 Vol. 1 IFAR7 Page 2 of 2 Issued: 2011-04-11 Canadian Classification Mark Data Page The minimum height of the registered trademark symbol shall be 3/64 of an inch. When the overall diameter of the UL Mark is less than 3/8 of an inch, the trademark symbol may be omitted if it is not legible. Camera-ready artwork and relative proportions are available online at www.ul.com. PROCUREMENT The manufacturer may reproduce the Mark or obtain it from an authorized label supplier. Authorized label suppliers can be found online at www.ul.com. THIS PAGE SHALL BE REVISED BY UL LABEL OPERATIONS ONLY

File E358903 Vol. 1 Index Page 1 Issued: 2012-10-29 INDEX Model Section Report Date USC/CNC X/X 22W1200 WOYZ, 18W1200 WOYZ and 22W1500 WOYZ series (Where W denotes Light-Emitting-Diode Retrofit Luminaire Conversion Kits, Models 10W600 WOYZ, 1 2012-07-05 LED package type, represent by A or B, O denotes the external power supply, Y denotes dimmer or not, represent by D or N, Z denotes End Caps Option, represent by S or T ) Light-Emitting-Diode Retrofit Luminaire Conversion Kits, Models 10W600 WINS, 22W1200 WIYS, 18W1200 WIYS and 22W1500 WIYS series (Where W denotes LED package type, represent by A or B, I denotes the Self-ballasted, Y denotes dimmer or not, represent by D or N, S Only one end cap) 1 2012-07-05 X Note: USC United States Standard, Classification CNC Canadian Standard, Classification.

C E R T I F I C A T E O F C O M P L I A N C E Certificate Number 20121030-E358903 Report Reference E358903-20120705 Issue Date 2012-OCTOBER-30 Issued to: JAMES INDUSTRY GROUP CO LTD R1205(S01), 12/FL TAI SANG BANK BLDG 130-132 DES VOEUX RD CENTRAL HONG KONG This is to certify that representative samples of LIGHT-EMITTING-DIODE RETROFIT LUMINAIRE CONVERSION KITS See Addendum Page Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Additional Information: See Addendum Page for additional Standards See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Classification Mark for the U.S. and Canada should be considered as being covered by UL's Classification and Follow-Up Service and meeting the appropriate U.S. and Canadian requirements. The UL Classification Mark includes: the UL in a circle symbol: with the word CLASSIFIED (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL s evaluation of the product; and the product category name (product identity) as indicated in the appropriate UL Directory. The UL Classification Mark for Canada includes: the UL Classification Mark for Canada: with the word CLASSIFIED (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL s evaluation of the product; and the product category name (product identity) in English, French, or English/French as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product. William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus Page 1 of 2

C E R T I F I C A T E O F C O M P L I A N C E Certificate Number 20121030-E358903 Report Reference E358903-20120705 Issue Date 2012-OCTOBER-30 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. USC, CNC - Light-Emitting-Diode Retrofit Luminaire Conversion Kits, Models 10W600 WOYZ, 22W1200 WOYZ, 18W1200 WOYZ and 22W1500 WOYZ series (Where W denotes LED package type, represent by A or B, O denotes the external power supply, Y denotes dimmer or not, represent by D or N, Z denotes End Caps Option, represent by S or T ). USC - Light-Emitting-Diode Retrofit Luminaire Conversion Kits, Self-ballasted LED Tube Lamps, Models 10W600 WINS, 22W1200 WIYS, 18W1200 WIYS and 22W1500 WIYS series (Where W denotes LED package type, represent by A or B, I denotes the Selfballasted, Y denotes dimmer or not, represent by D or N, S Only one end cap) Additional Standards for Safety: UL 1598, CSA C22.2 No. 250.0, the Standard for Luminaires, UL 1598C, the Outline Of Investigation for Light-Emitting Diode (LED) Retrofit Luminaire Conversion Kits, UL 8750, the Standard for Light Emitting Diode (LED) Equipment for Use in Lighting Products, CSA Technical Information Letter No. B- 79, Supplemental Requirements for Retrofitted Luminaires and LED Retrofit Kits for Installation into Previously Installed Luminaires William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus Page 2 of 2

File E358903 Project 12CA58458 July 5, 2012 REPORT On LIGHT-EMITTING-DIODE RETROFIT LUMINAIRE CONVERSION KITS Under the CLASSIFICATION PROGRAM JAMES INDUSTRY GROUP CO LTD Central Hong Kong, China Copyright 2012 UL LLC. UL LLC authorizes the above named company to reproduce this Report provided it is in its entirety.

File E358903 Vol. 1 Sec. 1 Page 1 Issued: 2012-07-05 PRODUCT COVERED: USC, CNC - Light-Emitting-Diode Retrofit Luminaire Conversion Kits, Models 10W600 WOYZ, 22W1200 WOYZ, 18W1200 WOYZ and 22W1500 WOYZ series (Where W denotes LED package type, represent by A or B, O denotes the external power supply, Y denotes dimmer or not, represent by D or N, Z denotes End Caps Option, represent by S or T ). USC - Light-Emitting-Diode Retrofit Luminaire Conversion Kits, Selfballasted LED Tube Lamps, Models 10W600 WINS, 22W1200 WIYS, ZY- T8-18W1200 WIYS and 22W1500 WIYS series (Where W denotes LED package type, represent by A or B, I denotes the Self-ballasted, Y denotes dimmer or not, represent by D or N, S Only one end cap). Note: USC United States Standards Classified CNC Canadian Standards Classified NOMENCLATURE: The complete lamp catalog number is as follows: Example: Catalogue No.: ZY-T8 10W600 W X Y Z 1 2 3 4 5 6 1 Series Designation 2 Designates for the power consumption and lamp length. 10W600 = 10 W, 600 mm length 22W1200 = 22 W, 1200 mm length 18W1200 = 18 W, 1200 mm length 22W1500 = 22 W, 1500 mm length 3 Designates for the LED rating. A = rated 2.9-3.4 V, max. 30 ma. B = rated 2.9-3.4 V, max. 70 ma. 4 Designates the Self-ballasted or not. O = external power supply. I = Self-ballasted. 5 Designates dimmer or not. N = Not suitable for dimmer. D = Suitable for dimmer. 6 Designates End Caps Option. S = Only one end cap. T = Double end caps.

File E358903 Vol. 1 Sec. 1 Page 2 Issued: 2012-07-05 ELECTRICAL RATINGS: LED tube with external LED driver: Retrofit Kit Model No. Length (mm) LED tube Model No. Input Voltage Vdc Input Current ma Input Wattage, W Type of fixture intended to be installed in Max. # of lamps allowed Weight LED driver 10W600 WOYZ 600 10W600 WOYZ Max. 29 250 10 Surface mounted 1 160g LD12W-36-C0250 for non-dimmable LD20W-36-C0250- LE for dimmable 22W1200 WOYZ 1200 22W1200 WOYZ Max. 37 550 22 Surface mounted 1 320g LD30W-42-C0550 for non-dimmable LD30W-42-C0550- RD for dimmable 18W1200 WOYZ 22W1500 WOYZ 1200 1500 18W1200 WOYZ 22W1500 WOYZ Max. 29 Max. 37 550 550 18 22 Surface mounted Surface mounted 1 1 310g 390g LD20W-36-C0550 for non-dimmable LD20W-36-C0550- LE for dimmable LD30W-42-C0550 for non-dimmable LD30W-42-C0550- RD for dimmable

File E358903 Vol. 1 Sec. 1 Page 3 Issued: 2012-07-05 Self-ballasted LED Tube: Retrofit Kit Model No. Length (mm) LED tube Model No. Input Voltage Vac Freque ncy,hz Input Current ma Input Wattage, W Type of fixture intended to be installe d in Max. # of lamps allowed Weight 10W600 WINS 600 10W600 WINS 100-277 (cover 100-120) 50/60 Max. 110 10 Type IC 3 210g 22W1200 WINS 1200 22W1200 WINS 100-277 (cover 100-120) 50/60 Max. 220 22 Type IC 3 380g 22W1200 WIDS 1200 22W1200 WIDS 90-140 50/60 Max. 220 22 Type IC 3 380g 18W1200 WINS 1200 18W1200 WINS 100-277 (cover 100-120) 50/60 Max. 190 18 Type IC 3 370g 18W1200 WIDS 1200 18W1200 WIDS 90-140 50/60 Max. 190 18 Type IC 3 370g 22W1500 WINS 1500 22W1500 WINS 100-277 (cover 100-120) 50/60 Max. 220 22 Type IC 3 460g 22W1500 WIDS 1500 22W1500 WIDS 90-140 50/60 Max. 220 22 Type IC 3 460g

File E358903 Vol. 1 Sec. 1 Page 4 Issued: 2012-07-05 TECHNICAL CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE): USC indicates investigation to UL 1598, the Standard for Luminaires, Third Edition, UL 1598C, the Outline Of Investigation for Light-Emitting Diode (LED) Retrofit Luminaire Conversion Kits, Second Edition and UL 8750, the Standard for Light Emitting Diode (LED) Equipment for Use in Lighting Products, First Edition. CNC indicates investigation to CSA C22.2 No. 250.0, the Standard for Luminaires, Third Edition and the CSA Technical Information Letter No. B-79, Requirements for Retrofitted Luminaires and LED Retrofit Kits for Installation into Previously Installed Luminaires, First Edition. CUL GENERAL CONSTRUCTION, MARKINGS, AND TESTS: Products bearing the C-UL mark shall comply with all applicable requirements of the C-UL portion of the Section General. In addition, the products shall also comply with the requirements of the Standard for Luminaires and the Standard for Light Emitting Diode (LED) Equipment for Use in Lighting Products (UL1598/UL8750/CSA C22.2 No. 250.0). Unless otherwise specified, all components of products bearing the C-UL mark shall be Listed or Recognized for Canada or CSA Certified, in addition to being UL Listed or Recognized.

File E358903 Vol. 1 Sec. 1 Page 5 Issued: 2012-07-05 CONSTRUCTION DETAILS: The product covered shall be constructed in accordance with the following description. Corrosion Protection All ferrous metal parts shall be protected against corrosion by painting, coating, plating, or the equivalent. Installation Instructions - A retrofit kit shall be provided with installation instructions that cover all aspects of luminaire alteration required for the installation of the LED retrofit kit. Each step shall be clearly explained and, when necessary, accompanied by an illustration showing execution of the step. All illustrations shall be legible to allow the installer to distinguish all applicable features of the luminaire and the LED retrofit kit. The installation instructions shall include photographs or line drawings of the luminaire or luminaires intended to be used with the retrofit kit clearly showing: a) The luminaire without the LED retrofit kit as it is seen by the installer of the retrofit kit; b) Details of all panels, brackets, and components and their orientation prior to luminaire alteration when these details are important to installation of the retrofit kit as it is intended to be used. For a LED retrofit kit that is bulk packaged, one set of installation instructions shall be provided with each carton. The installation instructions shall specify all components of the retrofit kit before any installation steps are given so that the user is able to check the content of the retrofit kit.

File E358903 Vol. 1 Sec. 1 Page 6 Issued: 2012-07-05 These products are intended to be used in dry locations only. These products are Classified as to FIRE and SHOCK hazards only.

File E358903 Vol. 1 Sec. 1 Page 7 Issued: 2012-07-05 MARKING: Units shall be legibly and permanently marked with the following. See Section General for marking format. MARKINGS: All markings shall be, legible, and visible after installation. The following markings are required. If label, must be R/C (PGDQ2) suitable for the surface and rated max 70 C and indicates that the marking shall consist of only the exact words shown or a marking including these words and conveying the original intent. Alternative wording for other markings may be used, subject to evaluation: 1. At least one of the components of a retrofit kit shall be marked with the retrofit kit manufacturer s name, trademark, or other descriptive marking in format S16-L2. 2. Model or Catalog number in format S16-L2. 3. Date Marking Code YYYYMMDD in format S16-L2. YYYY means the year, MM means the month, DD means the date. Example 20120712. 4. Input rating in volts, hertz and total amps or watts in format S24-L3. 5. This luminaire has been modified and can no longer operate the originally intended lamp shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including relamping in format S24-L1, Verbatim. 6. LED Lamp Replacement Marking Identification of the replacement LED lamp type/model to be used along with manufacturer and ordering information. Shall be marked on the retrofitted luminaire where readily visible by the user during routine maintenance such as relamping, in format S24-L1. For text, see item 8 below. 7. REPLACE ONLY WITH EPTRONICS INC {Catalog Number]XXX LED DRIVER for LED Tubes with external drivers in format S28-L1. XXX is to be replaced with the corresponding model number of LED driver. 8. REPLACE ONLY WITH ZHIYUAN LIGHTING TECHNOLOGY (HONGKONG) CO. LTD, [Catalogue Number] XXX. XXX is to be replaced with: the corresponding model number, as applicable. In Format S24-L6. 9. NOT FOR USE WITH DIMMERS for models which not suitable dimmer in format S16-L7 and S24-L5.

File E358903 Vol. 1 Sec. 1 Page 8 Issued: 2012-07-05 10. Classification Mark shall include the following or similar: LED RETROFIT LUMINAIRE CONVERSION FOR USE ONLY WITH PRODUCTS DESCRIBED AND INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT Control No. 4TZ2. 11. Devices substituting for linear fluorescent lamps, Models 10W600 WINS, 22W1200 WIYS, 18W1200 WIYS and 22W1500 WIYS series (Where W denotes LED package type, represent by A or B, I denotes the Self-ballasted, Y denotes dimmer or not, represent by D or N, S Only one end cap), connections for the source of electrical supply to the lamp pins shall be clearly marked on the lamp. 12. Devices substituting for linear fluorescent lamps, Models 10W600 WOYZ, 22W1200 WOYZ, 18W1200 WOYZ and 22W1500 WOYZ series (Where W denotes LED package type, represent by A or B, O denotes the external power supply, Y denotes dimmer or not, represent by D or N, Z denotes End Caps Option, represent by S or T ), the connections for the low voltage supply to the lamp pins shall include polarity, if the supply is a direct current type. 13. DOUBLE INSULATION or DOUBLE INSULATED or Symbol a square within a square for 100-277 V Self-ballast LED Tube in format S13L1. 14. MIN. LAMP COMPARTMENT DIMENSIONS _168(L)_X 103(W)_X 30(H) cm. 15. RISK OF ELECTRIC SHOCK USE IN DRY LOCATION ONLY. 16. SUITABLE FOR USE IN ENCLOSED SURFACE MOUNTED LUMINAIRES" for models with external LED driver.

File E358903 Vol. 1 Sec. 1 Page 9 Issued: 2012-07-05 Installation instructions shall include the following statements. 1. WARNING - Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. in format S24-L5. 2. WARNING - Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. in format S24-L5. 3. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. in format S24-L5. 4. WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. in format S24-L5. 5. "This luminaire has been modified and can no longer operate the originally intended lamp," shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including relamping. in format S24-L1. 6. LED Lamp Replacement Marking - Identification of the replacement LED lamp type/model to be used along with manufacturer and ordering information in format S24-L1. 7. WARNING: To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing shunted bi-pin lampholders. Note: Shunted lamp holders are found only in fluorescent luminaires with Instant- Start ballasts. Instant-start ballasts can be identified by the words Instant Start or I.S. marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer. Format S24-L5 8. Format Minimum Size Designation for Marking Height and Typeface SIZE DESIGNATION LETTER HEIGHT FONT TYPEFACE, mm UPPERCASE S16 1.6(0.062) Not specified S24 2.4(0.094) Univers bold Arial bold Helvetica bold Zurich BT Bold S32 3.2(0.125) Not specified S48 4.8(0.188) Univers bold Arial bold Helvetica bold Zurich BT Bold

File E358903 Vol. 1 Sec. 1 Page 10 Issued: 2012-07-05 Format Location Designation for Marking Location designation L1 L2 L3 L4 L5 L6 Description Visible during relamping, and after installation Visible during installation Visible during installation and inspection of wire connections, located near the supply connections On the smallest unit package or carton On an instruction sheet or tag Visible during component replacement Label exposed to a dry/damp environment Type P Type N Type N Type T Type T Type P Label exposed to a wet environment Type P Type P Type P Type T Type T Type P L7 On the lamp Type P Type P Type P designates a permanent label or nameplate that is intended to remain in the applied position for the lifetime of the luminaire under conditions of normal use. It provides information required for user maintenance over the expected life of the product. Type N designates a non-permanent label or nameplate that is intended to remain in place only for the purpose of installation. It shows the certification mark, manufacturer s identification, and product identification. It is made of paper with an adhesive backing. Type T designates a temporary label, instruction sheet, or tag that is not required after installation. It provides installation instructions, and information not required after installation. It is made of printed matter with or without adhesive and/or attachment, and is intended to be included with, or attached to, the product.

File E358903 Vol. 1 Sec. 1 Page 11 Issued: 2012-07-05 LED RETROFIT LUMINAIRE CONVERSIONS KIT Models 10W600 WINS, 22W1200 WIYS, 18W1200 WIYS and 22W1500 WIYS FIGS. 1-3; ILL. 1 General - The general design, shape and arrangement shall be as shown in Figs. 1 through 3, except where variations are specifically described below. All dimensions are nominal, within engineering tolerances, except where specifically indicated as a minimum or a maximum. Refer to ILL. 1 for Installation Instructions. LED Self-Ballasted Tube Lamp R/C (OOLV2/8), Models 10W600 WINS, 22W1200 WIYS, 18W1200 WIYS and 22W1500 WIYS series (Where W denotes LED package type, I denotes the Self-ballasted, Y denotes dimmer or not, S Only one end cap). Refer to File E354439, Vol. 1, Sec. 1 for details.

File E358903 Vol. 1 Sec. 1 Page 12 Issued: 2012-07-05 LED RETROFIT LUMINAIRE CONVERSIONS KIT Models 10W600 WOYZ, 22W1200 WOYZ, 18W1200 WOYZ and 22W1500 WOYZ FIGS. 4-6; ILL. 2-3. General - The general design, shape and arrangement shall be as shown in Figs. 1 through 3, except where variations are specifically described below. All dimensions are nominal, within engineering tolerances, except where specifically indicated as a minimum or a maximum. Refer to ILL. 2-3 for Installation Instructions. The products combine LED tube lamp, LED driver, lamp fixture (optional). LED Tube Lamp - M odels 10W600 WOYZ, 22W1200 WOYZ, 18W1200 WOYZ and 22W1500 WOYZ series (Where W denotes LED package type, O denotes the external power supply, Y denotes dimmer or not, dimmer type is with EOYX listed type, Z denotes End Caps Option). Refer to File E354439, Vol. 1, Sec. 1 for details.