User Manual. Version 1.4

Similar documents
LEDWash RGBW USER MANUAL

LED WASH LIGHT( 4 1) USER MANUAL

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

IMS Mk2 Universe Drive IP65 Quick Start Guide TMB 24/7 Technical Support

IMS MK2 Simple Universe Drive

ProPlex Digital RGB Drive PortableMount TMB 24/7 Technical Support

FloppyDrive 3x2 24V and 12V PortableMount USER MANUAL

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

LED-BANK4 USER MANUAL. COLORbank 4

LED-PAR200B USER MANUAL. COLORsplash 200B

Ilumipanel 36X3 IP Optic RGB

Snapshot. COLORado Panel USER MANUAL

User Manual. Version 1.3 Revised 05/17/17

Stratos Duo RGB. User Manual. Order code: EQLED371

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

Snapshot. COLORdash Batten USER MANUAL

Edition Notes. Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing

Ilumipod 36 IP Optic VW

1. BEFORE YOU BEGIN INTRODUCTION CONTROL FEATURES... 5 Additional Features... 5 PRODUCT OVERVIEW SETUP... 6

Edition Notes. Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing

Snapshot. User Manual. Use on Dimmer. Outdoor. Sound Activated DMX. Master/Slave Autoswitching Power Supply Replaceable Fuse.

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Snapshot. User Manual. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave Auto-ranging Power Supply Replaceable Fuse.

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

PART 1 PRODUCT (GENERAL)...1.

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

USER MANUAL Table of Contents

Edition Notes. Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing. Intended Audience. Disclaimer.

Edition Notes. Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing. Intended Audience. Disclaimer

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

thinpar 38

SquareLED - Aura Bar & Matrix Beam Light 100

Fusion 120 Zoom. User Manual. Order code: EQLED068

RIO TRI PAR MICROH. Information. Technical 104 F(40 C) 9.6 in (245 mm) Width. 9.6 in (245 mm) Height. 8.0 in (205 mm) Weight

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

COLORtube EQ Controller

LED ZOOM PAR Please R ead O ver T his M anual B efore O perating T he L ight F ixture.

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

Operation Manual Flare software version 8.8 Flare Jr software version 9.3C

VGAD-12 ORDERCODE

ORDER CODE: EQLED65 USER MANUAL

1. Before you Begin Introduction Setup Operation Technical Information Technical Specifications...

Quick Reference Guide

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

TABLE OF CONTENTS. Page 2 of 16 COLORband PiX IP User Manual (Rev. 1)

USER MANUAL Table of Contents

Table of Contents. COLORado 3 User Manual /10:56

192 Channel DMX Controller

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

Stage Flood QCL 24x10W, Stage Flood Inst QCL 24x10W LED floodlight. user manual

LED WASH RGBW XL. manual

LED Thunder S-150 Code 1097

Stage Flood Inst QCL 48x10W LED floodlight. user manual

Edition Notes. Edition Notes. Trademarks CHAUVET is a registered trademark of CHAUVET & Sons Inc. (d/b/a CHAUVET or

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

Edition Notes. Edition Notes. Trademarks CHAUVET is a registered trademark of CHAUVET & Sons Inc. (d/b/a CHAUVET or

Yoke Safety cable loop. Up Light Bulb

Hex-color RGBAW+UV LED strip light

Edition Notes. Edition Notes. Trademarks CHAUVET is a registered trademark of CHAUVET & Sons Inc. (d/b/a CHAUVET or

TABLE OF CONTENTS. 1. Before you Begin... 3 What is Included... 3 Unpacking Instructions... 3 Text Conventions... 3 Icons... 3 Safety Notes...

Snapshot DMX MEGA STROBE III. User Manual

Edition Notes. Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing. Intended Audience. Disclaimer.

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

PRO PAR HEX 12. User Manual

EDITION NOTES. Document Revision

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

USER MANUAL Table of Contents

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

TFX-950CM Stage Wash 950

LED Pixel Track V3 ORDERCODE 42200

ENGLISH Spectral M800 MKII

ICOLOR210Z. Imported from China by LOTRONIC S.A. Av. Z. Gramme 9 - B-1480 Saintes

BEFORE YOU BEGIN INTRODUCTION CONTROL FEATURES... 5 Additional Features... 5 PRODUCT OVERVIEW SETUP...

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

Snapshot. Obey 10 DMX Controller USER MANUAL

Venus W36 LED Moving Wash

Opti Tri White Par. User Instructions

LED Techno Strobe RGB ST-4000RGB USER MANUAL

ETC Quick Guide. Source Four LED Profile

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do

广州朗闻光电有限公司 GUANGZHOU LONGMAN PRO LIGHT FACTORY CO,. LTD. Vpower L350. System No.: LQ FULL RGBW

aorun manual V2.0 MARCH 2018

Mini Stage Par 4 8W QCL RGBA/RGBW 25 /40 LED PAR. user manual

LED Par 36 COB RGBW 12W, LED Par 46 COB RGBW 20W, LED Par 64 COB RGBW 60W, LED Par 56 COB RGBW 30W LED PAR. user manual

TABLE OF CONTENTS INTRODUCTION

Spectra Batten (Order code: LEDJ95)

Led Dynamic DMX Tri Curtain Manual

Glow P7B LED Par Beam

WaferPar QUAD-W 7 CKU (US) / CKE (EU) USER MANUAL

American DJ. User Instructions. Model: Mega Bar 50RGB

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. 115 V / 230 V Switchable. Replaceable Fuse.

DMX LED light effect with 4 lenses

LED Spot 300W. Please read this user manual before your operation

ENGLISH Spectral M800 Q4 IP65

Snapshot. Q-Wash LED USER MANUAL. Ok on Dimmer. Outdoor OK. Sound Activated. DMX/Master/Slave. 115V/230V Switch. Replaceable Fuse.

STAGE SETTER-8. User Instructions. Elation Professional 4295 Charter Street Los Angeles Ca

Transcription:

User Manual Version 1.4 Revised 05/17/17

1.BEFORE YOU BEGIN What is included 1 x Fixture 1 x Power cable with plug 1 x User Manual Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton; check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing. AC POWER This fixture has an auto-switching switch-mode power supply that can accommodate a wide range of input voltages. The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages. This fixture will accommodate between 100V and 240V AC 50-60 Hz. Each light is connected end to end by the power socket POWER IN and POWER OUT on the light Help preserve the environment! Ensure that this product is recycled at the end of its life. Your supplier can give details of local arrangements for the disposal of products. 2

Safety Instructions! WARNING! Please read these instructions carefully, which includes important information about the installation, usage and maintenance of this product.. The following symbols are used to identify important safety information on the product and in this manual:! DANGER! Safety hazard. Risk of severe injury or death DANGER! Hazardous Voltage. Risk of lethal or severe electric shock. WARNING! Fire hazard WARNING! LED light emission. Risk of eye injury. WARNING! Refer to user This light belongs to grade I protection device, therefore the light must connect to the earth excellently. And the power connection must be operated by the professional technician. Make sure that the working voltage will not higher or lower than the rated value. Make sure that the cable didn't be damage or lacerated by sharp. The light must be power off when it's standing idle or before clearing. The cable must with plug, and you must pull out the cable by handle the plug. Please be careful when installing the lighting. Never touch the bared cable, or it will cause the deadly electric shock. Please use the suitable and safe cable to connect the light. Please never remodel the light randomly, we will not take the guarantee for the faulty and damage which caused by dismantle repair or remodel of the nonprofessional person. Maximum ambient temperature 40 C. Do not operate fixture at temperatures higher than this. Never connect the device to a dimmer pack. Do not daisy chain power to more than 8 units @ 120V and 15 units @ 230V. 3

2.INTRODUCTION Specifications Voltage Rating: AC100V 240V 50-60Hz Power Rating: 65W Cos ö:0.67 Power Usage: 130VA LED Quantity: 9X4-in-1(RGBW) LED: 550mA Beam Angle: 50 Ingress Protection: indoor Product Size: 480x140x105mm Package Size: 510x210x175mm N/W:3.5Kg Features RGBW color mixing with or without DMX controller 5 distinct dimming curves User defined program/ inner optional program LED display with password protection Transfer custom programs between fixtures Operating Modes: DMX512 Connection with ID Address/Master & Slave... DMX Channels: HSV/11CH/03CH/04CH/DEF/ 05CH/06CH 3 channels(hsv): Hue+Saturation+Value 11 channels: Dimmer+RGBW+Macro + strobe + AUTO + Auto speed +dimming speed +ID 3 channels :RGB 4 channels :Dimmer+RGB 4 channels (DEF):RGBW 5 channels:dimmer+rgb W 6 channels:dimmer+rgbw + Strobe 4

Product Overview Control board Power in Power out 5pin DMX IN 5pin DMX OUT 3PIN DMX OUT 3PIN DMX IN Dimensions Hanging bracket/ floor stand Bracket adjustment knob 5

3.SETUP Installation Requirement This product can be used in a variety of situations, can hang and put on the ground. If hanging the fixture for over head use, then please follow the below steps. Please choose the suitable location to put or hang the light when installing it. You must use the exclusive clamp hanger and screw when hanging it, and make sure the weight of the light is within limits of the hanger. Please make sure without any flammable objects within 0.5m when installing the light. The installation should be operated by professional person; any irregular installation will cause the body injury or equipment damage. Block access below the work area and use suitable and stable platform when installing or servicing fixture. Hanging Clamp Note: sold separately Safety Cable Note: the cable must be secured through the heat sink ventilation passageway. 6

Connection of DMX Signal Wire 1 Please use the fixture controller wire specially when use the DMX512 Controller. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture. 2 Connect the end of the cable coming from the first fixture which will have a (male) 3 pin connector to the input connector of the next fixture consisting of a (female) 3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on. 3 This product can be connected numerous lamps in series without the need for the signal amplifier; the signal will not be weakened. DMX IN DMXOUT DMX IN DMXOUT DMX IN DMXOUT 3-PIN TO 5-PIN CONVERSION CHART Note! If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter. 3 PIN TO 5 PIN CONVERSION CHART Conductor Ground/Shield Data ( - ) signal Data ( + ) signal Do not use Do not use 3 Pin Female(output) Pin 1 Pin2 Pin 3 5 Pin Male (Input) Pin 1 Pin2 Pin 3 Do not use Do not use 7

4.OPERATING INSTRUCTIONS Control Panel Functions BUTTON MODE ENTER UP DOWN FUNCTION Exits from the current menu or function Enables the currently displayed menu or sets the currently selected value in to the selected function Navigates upwards through the menu list and increases the numeric value when in a function Navigates downwards through the menu list and decreases the numeric value when in a function Menu Map MAIN FUNCTION SUB- FUNCTION SELECTION INSTRUCTION (0 ~ 100%) User can combine RED, GREEN, BLUE and WHITE to generate a custom color 00~20 01~10 01~10 001~512 Select strobe frequency 10 auto programs available chose program from 10 EDIT programs Set DMX start address 8

MAIN FUNCTION SUB- FUNCTION SELECTION INSTRUCTION 01~66 ON~OFF Password OFF DIM1/2/3/4 Password V1.47 Sets the operating mode for the fixture:to receive signal from a DMX controller (DMX).receive signal or Download programs from Master fixture. (Slave) 3 channels Hue Saturation Value 11 channels D+RGBW+S 3 channels RGB 4 channels D+RGB 4channels RGBW 5 channels D+RGBW 6 channels D+RGBW+S Assign ID address for fixtures Enable or disable ID Upload programs(password required) "Off" means select linear dimming, or choose dimmer 1-4 to control the dimming speed, dimming 1 of the fastest dimming curves, 4 for the most slowly dimming curve Reset factory defaults Version number 01~09 custom 01~30 scene (0~255) custom 01~90 scene ON~OFF (0~20Hz)Select strobe frequency (0~255) step time transition time of last step to current step Enables or Disables password lockout 9

Operating instructions 1.Upload custom program or set to another machine Set all the fixtures which receive custom programs from the source fixture as Press MODE button until is displayed. Then press ENTER button, use UP/DOWN buttons until is displayed. Press MODE return to MENU On the Master unit, Press MODE button until is displayed on source fixture. Then press ENTER button, use UP/DOWN buttons until is displayed. Then press ENTER button, Input password UP, UP, DOWN, DOWN, press ENTER.All the lights display yellow color when uploading.after upload finish,it will turns to green which means upload successful.if has mistake,it will turns to red color. Press <MODE> on the source unit to exit the upload mode. 2 Enable password lock ON / OFF {ENTER} ON enable lock OFF disable lock Enable the password lock, control panel in the boot or go into standby automatically take effect, this time to operate lamps need to enter your password. { MODE UP MODE DOWN MODE UP MODE DOWN } {ENTER} 3 Factory reset {UP UP DOWN DOWN} {ENTER} Note: The password is permanently set as {UP UP DOWN DOWN} Then press ENTER button 4 Custom program Press MODE button until is displayed, press ENTER access program mode. Select the program you'll edit by pressing UP/DOWN buttons. The available range is o1-10. Select the step you'll edit by pressing UP/DOWN buttons, and then press ENTER button access program. 10

When 'R000' display on the screen, press the UP/DOWN button to choose the value. Repeat this step to edit the value of 'G000', 'b000','w000', 'S000', 'T000' and 'F000'. Please pay attention for the 'S' is the rate of strobe. 'T' is the operating time of the present step, the value is between 0 to 255. 'F' is the transition time from previous step to present step. The transition time is the quickest when the FADE is 0. Notice: Please operate the program in turn, from the 01st step to the 30th step. When the operating program less than 30 steps, please set the final step value be 0 Repeat step 3 till complete programming. Exit program mode by pressing MODE buttons three times. DMX512 Controller Mode 1 DMX operate mode setting Access control panel function by pressing MODE until is displayed. Press ENTER, press UP/DOWN buttons until the is displayed. Press ENTER, Press MODE return to MENU 2 Setting DMX512 Address 001--512 Access control panel function by pressing MODE until is displayed. Press ENTER, set starting address by pressing UP/DOWN between 001 and 512. Press MODE to exit. 3 Setting Channel Mode HSV/11CH/03CH/04CH/DEF/ 05CH/06CH Access control panel function by pressing MODE until is displayed. Press ENTER button, select DMX channel by pressing UP/DOWN, Press MODE to exit. 11

DMX512 Channel Values 11 channels Channel 1 Dimming 2 RED 3 Green 4 Blue 5 white 6 Macro color control 7 Strobe 8 auto & custom program Value 000~009 010~255 000~009 010~019 020~029 030~039 040~049 050~059 060~069 070~079 080~089 090~099 100~109 110~119 120~129 130~139 140~149 150~159 160~169 170~179 180~189 190~199 200~225 Description 0-100% 0-100%(Or STEP TIME when CUS.01-10 is activated) 0-10 0%(Or FADE TIME when CUS.01-10 is activated) 0-100% 0-100% No Function Macro color control Strobe(00~20Hz) No Function Out1 AUTO1 Out2 AUTO2 Out3 AUTO3 Out4 AUTO4 Out5 AUTO5 Out6 AUTO6 Out7 AUTO7 Out8 AUTO8 Out9 AUTO9 Out10 AUTO10 cust1 custom program 1 Cust2 custom program 2 Cust3 custom program 3 Cust4 custom program 4 Cust5 custom program 5 Cust6 custom program 6 Cust7 custom program 7 Cust8 custom program 8 Cust9 custom program9 Cust10 custom program10 12

13 ID ADDRESS SELECTION VALUE 000~009 010~019 020~029 030~039 040~049 050~059 060~069 070~079 080~089 090~099 100~109 110~119 120~129 130~139 140~149 150~159 160~169 170~179 180~189 190~199 200~209 210 211 FUNCTION All Ids ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 ID9 ID10 ID11 ID12 ID13 ID14 ID15 ID16 ID17 ID18 ID19 ID20 ID21 ID22 VALUE 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 FUNCTION ID23 ID24 ID25 ID26 ID27 ID28 ID29 ID30 ID31 ID32 ID33 ID34 ID35 ID36 ID37 ID38 ID39 ID40 ID41 ID42 ID43 ID44 Id45 VALUE 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 FUNCTION ID46 ID47 ID48 ID49 ID50 ID51 ID52 ID53 ID54 ID55 ID56 ID57 ID58 ID59 ID60 ID61 ID62 ID63 ID64 ID65 ID66 Channel 9 Auto Speed 10 Dimming speed 11 ID Value Description 0~100%(only when using ch.8) Dimming speed ID address selection

MASTER DIMMER Channels 1 controls the intensity of the currently projected color When the slider is at the highest position (255), then the intensity of the output is at themaximum. RED, GREEN BLUE AND WHITE COLOR SELECTION Channels 2, 3,4 and 5 control the intensity ratio of each of the Red, Green, Blue&white LEDs. 1,2,3,4 and 5 channel can be used in combinationr COLOR MACROS Channel 6 selects the required Color Macro. Channel 6 has priority over Channels 2, 3,4& 5. Channel 1 is used to control the intensity of the current Color Macro. STROBE Channel 7 controls the strobe of Channels 1 through 6. Channel 7 has priority over Channels 2, 3, 4 & 5. Speed of the strobe is adjustable from 0 to 20 Hz. AUTO & CUSTOM PROGRAMS Chanel 8 selects the preset Auto/Custom programs 1~10 When activating the Auto/Custom programs, it is then possible to control the Step time and Fade time by using Channels 2 & 3 respectively. Channel 8 has priority over channels 2-7. DIMMER SPEED Channel 10 is for selecting the dimmer mode and dimmer speed. When channel 10 is not activated, then RGBW and Master Dimmer are linear. The dimmer modes 1, 2, 3, and 4 are different speeds of the nonlinear dimming curves ID ADDRESS SELECTION Use channel 11 to select ID addressed fixtures. Each independent DMX address can have up to 66 ID addressed fixtures. ID address 0 allows control of all fixtures simultaneously. 14

3 channels HSV Channel Value 1 2 3 Description Hue Saturation Value (Intensity) Note: In HSV mode, Hue stands for the visible light, such as red, yellow, and cyan, etc. Saturation refers to the dominance of hue in the color; when saturation is at 100%, then the color is at its purest. Value is the color's brightness; when value is at 100%, then the color is at its brightest. 3 channels Channel 1 2 3 Value Description Red Green Blue 4 channels Channel 1 2 3 4 Value Description Dimming Red Green Blue 4 channels DEF Channel 1 2 3 4 Value Description Red Green Blue White 15

5 channels Channel 1 2 3 4 5 Value Description Dimming Red Green Blue White 6 channels Channel 1 2 3 4 5 6 Value Description Dimming Red Green Blue White Strobe ID Address Instructions 1.Setting ID address 1 Access control panel function by pressing MODE until is displayed. 2 Press ENTER, increase or reduce ID values by pressing UP/DOWN between 01 and 66. 3 Press MODE to exit. 2. Enable or disable ID ON-OFF 1 Access control panel function by pressing MODE until is displayed. 2 Press ENTER, select by pressing UP/DOWN until is displayed. 3 Press ENTER, turn on or off ID addressing by pressing UP/DOWN buttons. 4 Press MODE to exit. For every DMX512 address the user can set 66 separate ID addresses. ID addressing is a secondary function in DMX512 mode. In DMX512 Controller Mode, the user can simultaneously control the individual DMX address of all lights, and can control the lights which have separate ID address in independent DMX512. 16

DMX address:001 DMX address:001 DMX address:001 DMX address:008 ID address:01 ID address:02 ID address:03 ID address:01 DMX address:008 DMX address:008 ID address:02 ID address:03 Select STAG channel on fixture's control panel (Please refer to DMX512 Channels Selection). The figure above shows a simple DMX layout which has used three units at each DMX address. The three units have different ID addresses. In the DMX address: 001, the user can control the first three lights simultaneously. When using channel 11 select the channel number is 020-029 and ID Address=02, the controller can control the second light individually. When using channel 11 select the channel number is 000-010 and ID Address=00, all the lights are in common use at the same DMX address. 17

Master/Slave Control Mode 1 Setting master machine Access control panel function by pressing MODE until is displayed. Press ENTER, select or by pressing UP/DOWN buttons. Press ENTER, and then press MODE to exit. You can choose pre-set programs, the range is o1--10. Or you can choose custom programs, the range is o1--10. 2 Setting slave machine Access control panel function by pressing MODE until is displayed. Press ENTER, press UP/DOWN buttons until the is displayed. Press MODE return to MENU 3 Usage of Master/Slave When two or more fixtures connected, you can set up the first machine as the Master and the followed fixtures as Slaves. The Master can choose pre-set programs... or, all the slaves will follow the Master's operation synchronously. 5. APPENDIX Service Maintenance Guide Symptom(s) 1 or more LEDs are not illuminating Possible Solution(s) Clean the fixture regularly to avoid any such failure. This fixture is convection cooled, which means that if the surface is kept clean and free of debris, then proper cooling will be allowed to occur An LED may have failed, resulting in an open circuit. In this event, all of the red, green, or blue in a single module will no longer illuminate. This does not mean that all of the LEDs have failed, but the circuit is wired in series. An LED may have failed, resulting in a short circuit. In this event, only the single LED which has failed will no longer function. This does not mean that all of the LEDs have failed, but the circuit is wired in series. -Note: In the event of LED failure, a replacement LED PCB assembly may be purchased directly from Our company 18

Symptom(s) Breaker/Fuse keeps blowing Device has no power Fixture is not responding to DMX Loss of signal COLOR-CON Controller does not function, or does not function properly Stand alone operation The display is only showing: #### Possible Solution(s) Check total load placed on the electrical circuit Check for a short in the electrical wiring: internal and/or external Check for power on Mains -Note: In the event of autoswitching transformer failure, the unit can be sent in for repair; however, a replacement part can be ordered directly from Our company Check Control Panel settings for correct addressing Check DMX cables Check polarity switch settings on the controller Check cable connections Call service technician -Note: In the event of Display PCB failure, a replacement PCB can be ordered directly from Our company Use only DMX cables Install terminator Note: Keep DMX cables separated from power cables or black lights Make sure connector is firmly connected to device This fixture must be in the correct mode in order to properly respond to the COLOR-CON controller. The correct mode is DMX in the onboard Control Panel This fixture has built-in, automatic programs that may be triggered from the onboard Control Board The password lockout has been enabled. you can use the password: { MODE UP MODE DOWN MODE UP MODE DOWN } 19

Blow-out Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Description Dustproof acrylic LED Lens assembly LED Metal-core PCB assembly bearing side cover Bracket adjustment metal knob DMX socket LED Driver PCB case FAN Neutrik power socket Electronic Transformer Display Clear plastic cover LED Display PCB Display mounting apparatus Part Number 6D00207 4170901 2D00201 6D00208 6D00201 5020108 5040208 2D00202 6D00204 5060109 5050110 5080139 6D00212 2D00203 6D00203 20

Limited Warranty Nuri*Lites LED fixtures (the Product) are warranted by TMB against defective materials or workmanship for a period of one (1) year from the date of original sale by TMB. TMB s warranty shall be restricted to the repair or replacement of any part that proves to be defective and for which a claim is submitted to TMB before the expiration of the applicable warranty periods. This Limited Warranty is void if the defects of the Product are the result of: Opening the casing, repair, or adjustment by anyone other than TMB or persons specifically authorized by TMB Accident, physical abuse, mishandling, or misapplication of the product. Damage due to lightning, earthquake, flood, terrorism, war, or act of God. TMB will not assume responsibility for any labor expended, or materials used, to replace and/or repair the Product without TMB s prior written authorization. Any repair of the Product in the field, and any associated labor charges, must be authorized in advance by TMB. Freight costs on warranty repairs are split 50/50: Customer pays to ship defective product to TMB; TMB pays to ship repaired product, ground freight, back to Customer. This warranty DOES NOT cover consequential damages or costs of any kind. A Return Merchandise Authorization (RMA) Number must be obtained from TMB prior to return of any defective merchandise for warranty or non-warranty repair. For all repairs please contact TMB Tech Support Repair using the contact information below or email TechSupportRepairNA@tmb.com. US UK 527 Park Ave., San Fernando, CA 91340 21 Armstrong Way, Southall, UB2 4SD England Tel: +1 818.899.8818 Tel. +44 (0)20.8574.9700 Fax: +1 818.899.8813 Fax +44 (0)20.8574.9701 tmb-info@tmb.com tmb-info@tmb.com www.tmb.com www.tmb.com Return Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #). Products returned without an RMA # will be refused. Please contact TMB and request RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer s responsibility. TMB reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. Note: If you are given an RMA #, please include the following information on a piece of paper inside the box: 1) Your name 2) Your address 3) Your phone number 4) The RMA # 5) A brief description of the symptoms TMB 24/7 Technical Support US/Canada: +1 818.794.1286 Toll Free: 1 877.862.3833 (877.TMB.DUDE) UK: +44 (0)20.8574.9739 Toll Free: 0800.652.5418 e-mail: techsupport@tmb.com 21