GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

Similar documents
Technical Manager Dave Nott Tel: * Mo: Deputy Technical Manager Anton Holmes Tel: *

DEREHAM MEMORIAL HALL

New Theatre Royal Lincoln Technical Information

Theatre Technical Specifications

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Specification for the Alley Theatre, Strabane

Technical Specifications Nov 2016

Main House Technical Specification

Technical Specification Pavilion Dance

Technical Specification

INFORMATION FOR VISITING COMPANIES

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Theatre Technical Specification

Derby Theatre. Technical Information Main Stage. Derby Theatre. 15 Theatre Walk. St. Peters Quarter. Derby DE1 2NF.

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Stage. Get In & Parking

UNIVERSITY CONCERT HALL. Technical Specification

Dr JOHN GALLAGHER CONCERT CHAMBER

HIRE AND TECHNICAL INFORMATION

Technical Specification

The Haymarket Basingstoke Technical Specifications

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

The Georgian Theatre Royal Technical Information For Visiting Companies

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

TECHNICAL SPECIFICATION

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Main House Technical Specifications

Matt Dann Cultural Centre

Information for Incoming Companies

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

TECHNICAL SPECIFICATIONS

Technical Specifications

Pleasance London Main House Visiting Company Information Pack May 2017

Latrobe Performing Arts Centre

ISLAND HALL TECHNICAL INFORMATION

Technical Specification Ardhowen Theatre

Darlington Hippodrome Technical Specification

Cornerstone Technical Specifications 2018 / V1

Summary. Access and Parking

TECHNICAL SPECIFICATIONS

MAIN AUDITORIUM TECHNICAL INFORMATION

JERWOOD VANBRUGH THEATRE

Technical Information

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

MAIN THEATRE TECHNICAL SPECIFICATION

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Technical Specifications Updated 01/10/2017. Stage

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

CHELSEA THEATRE. Technical Specifications

Venue details. Stage Dimensions. Stage section Width Depth Height to Grid. Main Stage 8.8m (ex. wings) 7.32m 8.1m Baptistery 7.19m 6.4m 8.

Technical specifications Main theatre. Sound

Lighthouse Theatre Technical Specification

2017 TECHNICAL SPECIFICATIONS

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Hirers Technical Information Pack

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Technical Information

Technical Specification. Updated: April 2016

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Hopgood Theatre NOARLUNGA CENTRE

Technical requirements & conditions for hirers

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

ROSE THEATRE BASEMENT

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

CENTRE FOR PERFORMING ARTS

TECHNICAL SPECIFICATIONS

Arlington Arts Tech Spec 2018

Technical Specification Ver 01/16

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

Technical Specification

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Technical Information

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Technical Services and Specification

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Harlequin Vinyl floor (permanently installed) Clean removable Harlequin vinyl floor available for hire Rake

RPAC REDLANDS PERFORMING ARTS CENTRE

Sandusky State Theatre Technical Specifications

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

The Breen Center for the Performing Arts Saint Ignatius High School

ROSE THEATRE MAIN THEATRE

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Concert Hall Technical Specifications

Technical Specifications - Theatre

Compass Theatre - Technical Information Pack

Technical Specifications

Technical Specification 2016

MAIN HOUSE TECHNICAL SPECIFICATION

The Anvil Technical Specifications

Jane Mallet Theatre Technical Specifications

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Transcription:

WWW.GORDON-CRAIG.CO.UK BOX OFFICE 01438 363 200 GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

STAFF CHIEF TECHNICIAN (SOUND) Dave Nott Email: dave.nott@sll.co.uk Tel: 01438 242612 Mob: 07766 445779 DEPUTY CHIEF TECHNICIAN (STAGE) Anton Holmes Email: anton.holmes@sll.co.uk Tel: 01438 242612 SENIOR STAGE TECHNICIAN (LIGHTING) Alastair Rivers Email: al.rivers@sll.co.uk Tel: 01438 242614 STAGE TECHNICIANS Ashley Chappell Email: stagetech@sll.co.uk Tel: 01438 242614 Joe Leggett Alexandra Farrow In the first instance please direct all enquiries to backstage@sll.co.uk as this gets sent to the whole team. COMPANY OFFICE NUMBER Tel: 01438 242628 *Only in operation during in-house shows and at request of incoming companies. the gordon craig theate technical specification 1

STAGE Proscenium Arch, flat floor, Black Harlequin Cascade Dance Floor Access via Dock Door SL: Pros Opening - Adjustable: Proscenium Height: Proscenium to Rear Wall: Depth from Setting Line: Total Stage Width (inc Wings): FLYING SYSTEM 17 4 (5.28m) X 7 8 (2.34m) 30 0 (9.15m) to 40 0 (12.20m) 17 8 (5.38m) 26 0 (7.93m) Front of Stage 30 0 (9.15m) Iron Line 25 0 (7.62m) House Tabs 23 6 (7.16m) 83 0 (25.30m) 29 Double Purchase Counterweight Lines at 9 (0.23m) centres - operated SR from fly floor Grid Height: 49 4 (15.04m) Bar Length: 44 0 (13.41m) 9 0 Extension Bars Available Maximum S.W.L. of counterweight bars; 250kg U.D.L. DRAPES AND MASKING Standard Black Leg and Borders and Hard Masking Flats Additional Black Masking available on request. House Tabs motorised (Drop or Draw) operated from Prompt Desk SL. 1x pair of Black Tabs 1x Full Black Drape 1x White Seamless Cyclorama 1x Pale blue Festoon Drape 1x Pale blue Festoon Border 2x Pairs of Silver Swag Legs 1x Silver Swag Border 2x Black Shark tooth Gauze s 2x White Shark tooth Gauze 1x RGB LED Starcloth (DMX Controlled) the gordon craig theate technical specification 2 the gordon craig theatre marketing

STAGE MANAGEMENT Prompt Desk / Corner situated SL. Full headset and cue light (Twelve out stations) communication to all operational areas. Motorised House Tabs (Drop or Draw) and Safety Curtain rise. Show and Conductor View colour monitors, Infra-Red Show monitor. Show relay and tannoy call to all dressing rooms and backstage areas. Orchestra Pit Lift control, Stage Working light and Blues circuit control. Clock and Stopwatch, two 10A Independents. Steel Deck Staging 16-8 x 4 and 4-4 x 4 with 1, 2 and 3 foot legs. (Large quantity may be charged for and need prior arrangement) SCENERY To conform to Theatre Licensing Regulations, The Theatre s Duty Stage Manager may Fire Test any Scenery brought into the Theatre. Please speak to any of the Theatres Technical Staff if you have any queries. SPECIAL EFFECTS & HEALTH AND SAFETY Effects are considered to be any Pyrotechnics, smoke, haze, firearms, strobe lighting, bladed articles, special rigging etc. The Venue Stage Manager will require you to complete necessary paperwork on your arrival, this will include, Production Risk Assessments (Unless you can provide your own) and the Health and Safety & Evacuation Policy. You may also be asked for copies of any Industry Competency Certificates (IPAF, PASMA, etc), PAT Test Certificates, LOLER Certificates etc. THE THEATRE NEEDS 28 DAYS WRITTEN NOTICE FOR PERMISSION TO USE ANY EFFECTS AND WE RESERVE THE RIGHT TO REFUSE EFFECTS, RIGGING, USE OF ELECTRICAL EQUIPMENT AND ACCESS EQUIPMENT IF RISK ASSESSMENTS, METHOD STATEMENTS, SUPPORTING EVIDENCE OR CERTIFICATES ARE NOT PRODUCED OR IF SUFFICIENT NOTICE IS NOT GIVEN ORCHESTRA PIT Motorised Orchestra Pit and or Apron (operated from Prompt Desk). Accommodating maximum twenty musicians (this includes the conductor). Sixteen RAT illuminated music stands. BACKSTAGE AND DRESSING ROOMS Thirteen Dressing Rooms accommodating 70 people on two floors. Company Office situated on first floor dressing room 8. Direct line 01438 242628 Wardrobe Room with sink, automatic washing machine and 2x tumble dryer s situated on second floor. (There is NO LIFT to this floor) Green Room on ground floor with fridges, kettle, 2x microwaves, eating area, TV. Video Show Relay. Rehearsal Room with mirrors to one wall. Steinway Concert Grand, Kwai Baby Grand Piano. the gordon craig theate technical specification 3

LIGHTING EQUIPMENT Equipment ETC ION control desk ETC Sensor+ Dimmers Details Storage to USB 176 x 3kW circuits 34 x 5kW circuits 24 x Non-Dim / Independents Circuit No Load Location Phase 1-24 3kW FOH Bridge L1 25-30 5kW FOH Bridge L1 31-38 3kW FOH SR Juliet L1 37-42 3kW FOH SL Juliet L1 43-48 3kW FOH SR Side Bar L1 49-54 3kW FOH SL Side Bar L1 55-72 3kW LX 1 (18 Way IWB) L2 73-90 3kW LX 2 (18 Way IWB) L2 91-108 3kW LX 3 (18 Way IWB) L2 109-118 5kW Auxiliary (10 circuits) L3 119-126 3kW Auxiliary (8 circuits) L3 127-132 5kW Auxiliary (6 circuits) L1 133-144 3kW Auxiliary (12 circuits) L3 145-150 3kW DSL Dips L2 151-156 3kW DSR Dips L2 157-162 5kW USL Dips L2 163-168 5kW USR Dips L2 171-176 3kW NON-DIM FOH Bridge L1 177-178 3kW NON-DIM FOH SR Juliet L1 177-178 3kW NON-DIM FOH SL Juliet L1 179-180 3kW NON-DIM LX 1 (patch floor SL) L1 181-182 3kW NON-DIM LX 2 (patch floor SL) L1 183-184 3kW NON-DIM LX 3 (patch floor SL) L1 185-186 3kW NON-DIM Auxiliary (patch floor SL) L1 187 + 179b 3kW NON-DIM DSL Dips L2 188 + 180b 3kW NON-DIM DSR Dips L2 189 + 181b 3kW NON-DIM USL Dips L2 190 + 182b 3kW NON-DIM USR Dips L2 191 + 192 3kW NON-DIM Orchestra Pit L3 P1 - P3 3kW Orchestra Pit SL (patch circ.) L3 P4 - P6 3kW Orchestra Pit SR (patch circ) L3 197-200 2x 3kW, 2x 5kW House Lights L3 201-206 3kW FOH Auditorium Rear L1 207-212 3kW FOH Bridge Auxiliary L1 213-214 3kW SL Juliet L1 215-220 3kW DSL Dips L2 221-226 3kW DSR Dips L3 227-232 3kW USL Dips L2 233-238 3kW USR Dips L3 All on stage bars are supplied via socapex. ETC-NET Outputs: Cat 5E, Situated: FOH Bridge, Patch Floor All Stage Dips DMX Outputs: 5 Pin XLR, Situated: FOH Bridge, LX 1, LX2, LX3. All Stage Dips the gordon craig theate technical specification 4

LIGHTING EQUIPMENT 24 Source Four 15/30 750W Profile Spots. STD Rig FOH 12 Source Four 25/50 750W Profile Spots. STD Rig On Stage 36 Robert Juliat Lutins 1000W Fresnels. STD Rig On Stage. 36 Strand Cantata F 1200W Fresnels. 15 Strand Cantata 26/44 1200W Profile Spots. 11 Strand Cantata 18/32 1200W Profile Spots. 12 Strand Cantata 11/26 1200W Profile Spots. 42 Par 64 Cans 1000W Beamlights. 38 x Std Rig (We can provide all Lanterns in any combination of CP60,61,62 you require by prior arrangement) 14 Phillips PLCYC1 125W LED Floods. Std Rig Cyc Colour Wash. 2 Robert Juliat Korrigan Follow spots 1200W HMI Hire Charge for this equipment 12 Rainbow Pro 8 Scrollers Hire Charge for this equipment Scroll Colour A - 130,103,152,154,107,111,201,144,118,132,119,126,139,122,128,164,106,179,102,101 Scroll Colour B - 029,128,111,107,136,156,179,138,122,442,152,763,103,130,203,202,201,719,197,195, 118,132, #74 Bespoke or Stock scrolls must be ordered 4 weeks in advance. 2 Le Maitre G150 Smoke Machines Hire charge for this equipment 2 Jem ZR-44 Hi-Mass DMX Smoke Machines Hire charge for this equipment 2 Le Maitre MVS Hazer Hire charge for this equipment 4 Robe 575 AT moving head Intelligent lights Hire charge for this equipment Installed Gobos may vary from Standard Various Socapex cable, 6 and 12 way IWB s, 15A Extension cables, Grelcos, 6 x Tank traps stands, Booms, T- Bars, Gobos and holders. Full range of LEE Filters Colours 101-206 available, please check with theatre staff your Colour Filter is available. Additional lighting equipment maybe hired by arrangement with the Theatre staff All Theatre Lanterns and Colour Filter subject to availability the gordon craig theate technical specification 5 the gordon craig theatre mar- keting guide 3

MAINS POWER Toured LX Supply. Three Phase 200A Busbar Chamber situated SL. Toured LX Supply. Three Phase 63A Single Phase 63A Situated DSL Fitted 63A TPN and 63A SPN Ceeforms. Toured LX Supply. Three Phase 63A Single Phase 63A Situated Patch Floor SL. Fitted 63A TPN and 63A SPN Ceeforms. Toured Sound Supply. Single Phase 63A Situated DSL. Fitted 63A SPN Ceeform. Single Phase 32A Situated DSL. Fitted 32A SPN Ceeform. Single Phase 16A Situated DSL. Fitted 16A SPN Ceeform. Single Phase 63A Situated DSR. Fitted 63A SPN and 2x 32A SPN Ceeform. Toured Sound Multicore and Power Run 50M required. Running Stage Right. Multicore and Power Run 75M required. Running Stage Left. the gordon craig theate technical specification 6

SOUND EQUIPMENT Mixers Yamaha CL5 v3 72+8 channels (FOH STD) Yamaha QL5 v3 64+8 channels (Hire Charge) Interfaces 2 x Yamaha Rio 3224-D Stage Left & Right 1 x Yamaha RSio64-D System Outputs Front Of House 12 x d&b audiotechnik T10 L & R. 4 x d&b audiotechnik T10 Cluster 4 x d&b audiotechnik B4-SUB Sub 6 x d&b audiotechnik E6 * Front Fills * This is a permanent line array system and cannot be moved. *Not permanently installed due to the motorized apron, there is a hire charge for the front fill speakers. Please phone to discuss hire charge. Foldback/Monitors 4 x d&b audiotechnik E9 Foldback / Monitors 2 x JBL SoundFactor 15 s Foldback / Monitors. 6 x JBL Eon 10 Foldback / Monitors 6 x MyMix Personal Mixers * Personal Mixers * 1 x MyMix IEX-16 (ADAT Input) * Personal Mixers * *There is a hire charge for the MyMix Personal Mixers. Please phone to discuss hire charge. Amplifiers 1 x d&b audiotechnik 30D L & R 1 x d&b audiotechnik 30D Cluster and Sub 1 x d&b audiotechnik 10D Front Fills 1 x d&b audiotechnik 10D Foldback 2 x Yamaha P3200 Foldback the gordon craig theate technical specification 7

SOUND EQUIPMENT Patch Full Cat5E Patch to all areas for Dante/Control/MyMix 6 x Cisco SG200-26P Managed Switches (Running V-Lans) Full Analogue XLR Patch to S/L, S/R, U/S, Orchestra Pit Microphones 5 x Shure SM 58 4 x Shure SM 57 4 x Sennheiser ME 66 shotgun 10 x Sennheiser MKH 50 4 x Beyer Dynamic M201 An extensive list of microphones is available on request. Radio Mic Kit UHF 16 x Sennheiser EM500 G2 Receivers & SK500 G2 Transmitters 12 x Sennheiser EM500 G3 Receivers & SK500 G3 Transmitters All Radio Mics use MKE-2 Gold mic head 4 x Sennheiser SK-965 hand held Transmitter *There is a hire charge for all radio mics. Please phone to discuss hire charge. Direct Injection Boxes 8x BSS AR-133 DI Boxes Show Control 1x CTR Electronics CSC Show Control PC* - Dante Virtual Soundcard Output over Cat5 - Nemesis UMT-2D MIDI Control - Full On-Site CSC Software License *Permanent Installation in Sound Box, Cannot be used at temporary FOH Position Additional Sound equipment maybe hired by arrangement with the Theatre staff All Sound Equipment subject to availability the gordon craig theate technical specification 8