Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Similar documents
Perle Fast Ethernet Media Converters

Perle Fast Ethernet Media Converters

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

User s Guide TN-GB-SM512. Gigabit Interface Converter (GBIC) Transceiver Modules

OptEnet OC48 Regenerator Module User Manual

Small Form-Factor Pluggable (SFP) Module Installation Guide

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

Product Operation Manual

USER S GUIDE NEC-GXE-xx Base-X Fiber ExpressCard

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

Owner s Manual. 10/100 Media Converters. Models: N SC-MM (850nm), N SC-15 (1310nm) 10/100/1000 Media Converters

USER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode

Single mode 9/125µm, duplex

User s Guide F-SM-MM-02 Stand-Alone Media Converter Fast Ethernet or ATM Singlemode to Multimode

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

USB-0100TX USB Fast Ethernet Converter. User s Guide

User s Guide CSETF10xx-205 Slide-in-Module Media Converter Ethernet and Fast Ethernet 10/100Base-TX to 10/100Base-SX

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

Fiber Converters TFC-110 Series. ŸQuick Installation Guide (1)

OM2000N INSTALLATION MANUAL

Fiber Converters TFC-1000 Series. ŸQuick Installation Guide (1) ŸTechical Specifications (4)

33415 Rev. B Page 1 of 22

VersiVision. FVTMHA0xA / FVRMHA0xA 16-CHANNEL DIGITALLY ENCODED VIDEO 1-CHANNEL BI-DIRECTIONAL DATA MULTIPLEXER USER S MANUAL.

opengear OPG-1L 50 MHz-2.3 GHz

FiberLink 7142 Series

UNDER TABLE 4X1 HDMI SWITCHER

Ethernet Media Converters

I N S T R U C T I O N D A T A

IEC G-port Gigabit smart rackmount Ethernet switches STAT PWR1 PWR2 FAULT FDX/HDX MODE. Warranty

Quick Start Guide. Wireless TV Connection with Dongle. GWHDKITD PART NO. Q1504-b

User s Guide J/RS232-xx-01 Stand-Alone Media Converter Just Convert-It RS-232 to Fiber

MultiMode FOMs -ST and -SMA

TP /351 HDMI Over Coax with IR

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

MT IN, 2-OUT CAT-5 TO VGA RECEIVER CARD FOR MULTI-TASKER USER S GUIDE

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

VGA to DVI Extender over Fiber SET

Quick Start Guide. Wireless TV Connection with Dongle. GWHDKITD PART NO. Q1504

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

DA1931CT/ TP to Video + Audio Receiver

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater. Installation and Operations. Manual

SYNC/VIDEO, SYNC FOR MULTI-TASKER MATRIX SWITCHER USER S GUIDE

HD1-DX HDMI Extender

ES-3305P / ES-3308P / ES-3316P. Quick Installation Guide / v1.0

Synchronous Fiber Optic Modem

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

HFC. Enhance. QHFCN CATV Optical 2-way Mini Node Installation & Operation Guide

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

MultiView T4 / T5 Transmitter

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

ASP-FIBRS1 User Manual

TC3005(LED/ELED/LASER) User's Manual

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

LONWORKS Fibre Optic Converter

AP61 Hardware Installation Guide

User s Guide SSETF10xx-205 Stand-Alone Media Converter Ethernet and Fast Ethernet 10/100Base-TX to 10/100Base-SX

VersiVision. FVTM2BBxA / FVRM2BBxA 2-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA 2-CHANNELS BI-DIRECTIONAL AUDIO

IMC-21A Series. Industrial 10/100BaseT(X) to 100BaseFX media converters. Introduction. Specifications. Ethernet Media Converters and Extenders

ViaLiteHD Fibre Optic Green OEM Link Modules

FiberLink 3350 Series

D3.1/CCAP Compliant HFC. Enhance. QHFCN CATV Optical 2-way Mini Node INSTALLATION & OPERATION MANUAL.

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

In-Band OAM Gigabit Ethernet to MM LC Fiber Media Converter - 550m, Metal Housing

FOM-9010, FOM-9011 and FOM-9012

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

Fiber Optic Meter Fiber Optic Source

E3/DS3 Fibre Extender

OPERATION MANUAL INSTALLATION AND KML.F. Fiber Optic Interface Main Link. Kilomux Module. The Access Company

One channel video link With duplex data and contact closure

3G/HD/SD-SDI to HDMI Converter

twister Mbps Multimode-to-Singlemode Media Converter

Metrobility. Installation & User Guide Model: R380-SS MULTIRATE PWR

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

LONWORKS Fibre Optic Router

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

19 / 20.1 / 22 WIDE SCREEN TFT-LCD MONITOR

Fibre Optic Modem ODW-611

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

SVIDF201x-100. SVIDF201x-110

User s Guide SRS2F Stand-Alone Media Converter RS-232 to Fiber

HD1-LX HDMI & IR Extender

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

HDMI to VGA Converter

Quick Installation Guide. TFC-1000 TFC-210 Series TFC-2000 Series

Reference Manual D VD 5820

25W 9xxnm Uncooled Multimode Laser Diode Module

Fibre Optic Modem ODW-622

Transcription:

Perle Fast Ethernet Fiber to Fiber Media Converter Module Installation Guide C-100MM-XXXXX CM-100MM-XXXXX Unmanaged Module Managed Module P/N 5500313-10 (Rev D)

Overview This document contains instructions necessary for the installation and operation of the Perle Fast Ethernet Fiber to Fiber Media Converter Module(s) (C-100MM and CM-100MM) that are used in conjunction with a Perle MCR chassis. The C-100MM are the unmanaged media converter modules, and the CM-100MM are the managed versions. These products allow dissimilar 100Base- X fiber interfaces to connect to each other. These are the fiber to fiber conversion models: Multimode to Multimode (MM) Multimode to Single Mode () Multimode to Single Mode Single Strand () These media converter modules operate over different wavelengths and distances, depending on the model selected (See tables below). For information on the management options of the CM-100MM converter module, refer to the MCR-MGT Module User s Guide. Fiber port 1 MM1 Model Connector Mode Distance Wavelength (TX/RX) All models SC/ST/LC MM. 2 km/1.2 mi. 1310 nm Fiber port 2 MM2/2 Model Connector Mode Distance Wavelength (TX/RX) C-100MM-M2xx2 CM-100MM-M2xx2 C-100MM-S2xx20 CM-100MM-S2xx20 C-100MM-S2xx40 CM-100MM-S2xx40 C-100MM-S2xx80 CM-100MM-S2xx80 C-100MM-S2xx120 CM-100MM-S2xx120 C-100MM-S1xx20U CM-100MM-S1xx20U SC/ST/LC MM 2 km/1.2 mi. 1310 nm SC/ST/LC 20 km/12.4 mi 1310 nm SC/ST/LC 40 km/24.9 mi 1310 nm SC/ST/LC 80 km/49.7 mi 1550 nm SC/ST/LC 120 km/74.6mi 1550 nm SC/ST 20 km/12.4 mi. 1310/1550 nm Fast Ethernet Fiber to Fiber Media Module Installation Guide 2

C-100MM-S1xx20D CM-100MM-S1xx20D C-100MM-S1SC40U CM-100MM-S1SC40U C-100MM-S1SC40D CM-100MM-S1SC40D SC/ST 20 km/12.4 mi. 1550/1310 nm SC 40 km/24.9 mi. 1550/1310 nm SC 40 km/24.9 mi. 1550/1310 nm Note: Please refer to Perle s web site for the most up to date Installation guides, models and specifications http://www.perle.com/ Fast Ethernet Fiber to Fiber Media Module Installation Guide 3

Installation The media module comes equipped with a bank of DIP switches and jumpers for setting configuration. The default DIP switch settings (all switches in the UP position) and jumper settings will work for most installations. The following steps are used to configure the Perle Fast Media Converter Module: Set the Auto-Config jumper. (CM-100MM only) (optional) Set the DIP switch settings. (optional). Insert the media module into the chassis. Connect fiber cable 1 to port MM1. Connect fiber cable 2 to port MM2/2. Auto-Config Jumper (CM-100MM only) The Auto-Config jumper is J5. Refer to the diagram below for labelling. This jumper only applies to the CM-100MM converter module. Auto (Pin 2 and Pin 3 are strapped): When set to Auto. At power up the media module will, check its internal flash memory to see if configuration information has been downloaded to it from a management module. If so, the media module will use this configuration as its running configuration. If there is no configuration in flash, the media module will read the settings of the DIP switches and use those settings as its running configuration. SW (Pin 1 and Pin 2 are strapped): When set to SW (Switch). At power up, the media module will read the settings of the DIP switches and use those settings as its running configuration. The media module will ignore any configuration information in its flash memory. Note: The default jumper setting is Auto Fast Ethernet Fiber to Fiber Media Module Installation Guide 4

DIP Switch Settings Note: All switch changes take effect immediately and will result in a link reset on both fiber ports. Link Mode (Switch 1) Switch Position Up (default) Mode Link Pass-Through Mode Down Standard Mode Link Pass-Through: In this mode, the link state on one fiber connection is directly reflected through the media module to the other fiber connection. Standard Mode: In this mode, each fiber link can be brought up and down independently of each other. A loss of link on either fiber connection can occur without affecting the other fiber connection. Fast Ethernet Fiber to Fiber Media Module Installation Guide 5

Far End Fault (Switch 2) Switch Position Up (default) Mode Enabled Down Disabled Enabled: If the media module detects a loss of fiber signal on the fiber receiver, the media module will immediately send a FEF on the transmitter of its fiber link to the remote end module. This, in effect, notifies the fiber link partner that an error condition exists on the fiber connection. Note: This switch needs to be set to either generate or detect the Far-End Fault signal. Disabled: The media module will not monitor for, or generate Far End Fault. Illustration of the FEF feature Media Converter A Configuration Link Mode Standard Mode Far-End Fault Enabled Media Converter B Configuration Link Mode Link Pass Through Mode Far-End Fault Enabled Fast Ethernet Fiber to Fiber Media Module Installation Guide 6

Sequence of Events 1. Media module A loses fiber connection (RX) on MM2/2. 2. Media module A sends FEF on transmitter (TX) MM2/2. 3. Media module B detects loss of fiber link on receiver RX MM2/2. 4. Media module B turns off transmitter (TX) on MM1. 5. Media module A MM1 is not affected. Remote Loopback Fiber 1 (Switch 3) Switch Position Up (default) Mode Disabled Down Enabled Disabled: This is the normal position for regular operation. The switch must be set to this position in order for data to pass through the media module. Enabled: This is a test mode. All data received on the receive (RX) fiber connection is looped back to the transmit (TX) fiber connection. Note: Only one fiber interface can be in loopback at a time. Remote Loopback Fiber 2 (Switch 4) Switch Position Up (default) Mode Disabled Down Enabled Disabled: This is the normal position for regular operation. The switch must be set to this position in order for data to pass through the media module. Enabled: This is a test mode. All data received on the receive (RX) fiber connection is looped back to the transmit (TX) fiber connection. Note: Only one fiber interface can be in loopback at a time. Fast Ethernet Fiber to Fiber Media Module Installation Guide 7

Installing Media Converter Modules Caution: Observe electrostatic discharge precautions when installing the media module(s) into the chassis. Failure to observe this caution could result in damage to the module(s) and/or chassis. The Perle media module can be installed in any available slot and in any order within the MCR chassis. Remove the media module from its packaging. Using a cross-head screwdriver, remove the screw holding the face plate to the chassis to reveal the slot opening. Set the jumpers and DIP switches on the media module to the desired operating mode. (optional) Locate the top and bottom alignment guides inside the MCR chassis. Using the module alignment guides gently slide the module into the slot until it becomes flush with the front of the chassis. Light pressure may be needed to seat the module. Do not force the module as you might cause damage. If there is resistance, remove the module and check the module connector for damaged or incorrectly aligned pins. If these are not damaged, retry to insert the module. Tighten the captive retainer screw to ensure the media module is locked in place. Remove the dust caps from the fiber connectors and connect the fiber cables. Fast Ethernet Fiber to Fiber Media Module Installation Guide 8

Removing Media Convert Modules Loosen the captive retainer screw on the front of the media module and gently pull the module towards you. If not inserting a replacement media module cover the opened slot with a face plate and secure the screw. Installing the Duplex Fiber Cable Locate a 100Base-X compliant duplex (2 strands) fiber cable with the appropriate connectors. Connect the fiber cables from the media module to the other media module/switch/fiber device ensuring that the RX and TX are reversed at the opposite end. Installing the Simplex Fiber Cable Locate a 100Base-X compliant simplex (1 strand) fiber cable with appropriate connectors. Connect the fiber cable from one media module to another media module/converter/switch/fiber device. Fast Ethernet Fiber to Fiber Media Module Installation Guide 9

Operation Status LED The Perle Fast Ethernet Media Converter modules have three single colored status LEDs located on the face plate of the module. PWR - Power/Test On- Power is on, the module is operating normally. Blinking- slowly: the module is in loopback mode. Blinking- quickly: the module has a hardware error. LK1 MM1 (Fiber Link 1) Activity On- Fiber link present. Blinking- quickly: Fiber link present and receiving data. Off- No fiber link present. LK2 MM2/2 (Fiber Link 2) Activity On- Fiber link present. Blinking- quickly: Fiber link present and receiving data. Off- No fiber link present Fast Ethernet Fiber to Fiber Media Module Installation Guide 10

Troubleshooting General Ensure the module is correctly seated to the backplane in the MCR chassis. The PWR LED should be on solid. Ensure all cabling is of the correct type and is in good working order. Ensure both devices on either end of the fiber are compatible. If using a simplex fiber connection, ensure that you have both an Upstream (U) and Downstream (D) media module. For duplex fiber connections, ensure the RX and TX has been reversed between the two media converter module. No connectivity If unable to get full connectivity with all DIP switches in the UP position, these methods are recommended for troubleshooting. Note: If troubleshooting a CM-100, setting the Auto-Config jumper (J5) to SW will ensure the DIP switches are being read. Method 1 1. Set the Link mode to Standard (SW1 Down) on both media converter module. Leave all other switches in the Up position. 2. Connect the near end device to the MM1 port. The LK1 should be lit to indicate a good fiber connection. If the LK1 LED is not lit, then check the fiber cable and the attached device. 3. Repeat step 2 for the MM2/2 port 4. Return the media module to the desired configuration. Method 2: The fiber connection can also be verified by configuring the remote media module for loopback mode. The LEDs on both media converter module should be lit. Data should pass through the local module, over the fiber connection to the remote media module. At the remote media module, the data will be looped back and passed through MM2/2 transmit fiber link. Fast Ethernet Fiber to Fiber Media Module Installation Guide 11

Technical Specifications The following applies to all C-100MM and CM-100MM media converter modules: Maximum Power Consumption 3.5 watts Operating Temperature: 0 C to 50 C (32 F to 122 F) Storage Temperature: -25 C to 70 C (-13 F to 158 F) Operating Humidity: 5% to 90% non-condensing Storage Humidity: 5% to 95% non-condensing Operating Altitude: Up to 3,048 m (10,000 ft) Weight: 0.15 kg (0.33 lbs) MTBF: (C-100MM) 484,202 hours (CM-100MM) 489,076 hours Fiber Optic Specifications Fiber port 1 MM1 Model C-100MM-M2SC2 CM-100MM-M2SC2 Mode MM Wave length (nm) RX: 1310 TX Power Min: -20 Max: -12 RX Power Min: -31 Max: -14 Budget 11 Fiber port 2 MM2/2 Model C-100MM-M2SC2 CM-100MM-M2SC2 Mode MM Wave length (nm) RX: 1310 TX Power Min: -20 Max: -12 RX Power Min: -31 Max: -14 Budget 11 C-100MM-M2ST2 CM-100MM-M2ST2 MM RX: 1310 Min: -20 Max: -12 Min: -31 Max: -14 11 C-100MM-M2LC2 CM-100MM-M2LC2 MM RX: 1310 Min: -20 Max: -12 Min: -30 Max: -14 10 C-100MM-S2SC20 CM-100MM-S2SC20 RX: 1310 Min: -18 Max: -7 Min: -32 14 C-100MM-S2ST20 CM-100MM-S2ST20 RX: 1310 Min: -15 Max: -8 Min: -32 17 C-100MM-S2LC20 CM-100MM-S2LC20 RX :1310 Min: -15 Max: 0 Min: -34 Max: -5 19 C-100MM-S2SC40 CM-100MM-S2SC40 RX :1310 Min: -5 Max: 0 Min: -34 29 Fast Ethernet Fiber to Fiber Media Module Installation Guide 12

Model Mode Wave length (nm) TX Power RX Power Budget C-100MM-S2ST40 CM-100MM-S2T40 RX :1310 Min: -5 Max: 0 Min: -34 29 C-100MM-S2LC40 CM-100MM-S2LC40 RX :1310 Min: -5 Max: 0 Min: -34 29 C-100MM-S2SC80 CM-100MM-S2SC80 Min: -5 Max: 0 Min: -34 29 C-100MM-S2ST80 CM-100MM-S2ST80 Min: -5 Max: 5 Min: -34 29 C-100MM-S2LC80 CM-100MM-S2LC80 Min: -5 Max: 0 Min: -34 29 C-100MM-S2SC120 CM-100MM-S2SC120 Min: 0 Max: 5 Min: -35 35 C-100MM-S2ST120 CM-100MM-S2ST120 Min: 0 Max: 5 Min: -35 Max: 0 35 C-100MM-S2LC120 CM-100MM-S2LC120 Min: 0 Max: 5 Min: -35 35 C-100MM-S1SC20U CM-100MM-S1SC20U Min: -14 Max: -8 Min: -32 18 C-100MM-S1SC20D CM-100MM-S1SC20D RX:1310 Min: -14 Max: -8 Min: -32 18 C-100MM-S1ST20U CM-100MM-S1ST20U Min: -15 Min: -3 4 12 C-100MM-S1ST20D CM-100MM-S1ST20D RX:1310 Min: -15 Min: -3 4 12 C-100MM-S1SC40U CM-100MM-S1SC40U RX:1550 Min: -8 Min: -33 25 C-100MM-S1SC40D CM-100MM-S1SC40D RX:1310 Min: -8 Min: -33 25 Fiber Cabling Requirements: MM: : 50/125 microns or 62.5/125 microns 9/125 microns Note: Please refer the product page on the Perle website for the most up to date specifications. http://www.perle.com/ Fast Ethernet Fiber to Fiber Media Module Installation Guide 13

Compliance Information FCC This product has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this Guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. EN 55022, Class A, WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. EN 55024, Class A Laser Safety IEC 60825-1:2007 This product meets Class I Laser safety requirements per IEC-60825-1:2007 standard and complies with FDA/CDRH 21 CFR1040.10 and 21 CFR1040.11. WARNING: Visible and invisible laser radiation may be present when cables are not connected. Do not stare into the beam or view the beam directly with optical instruments. Failure to observe this warning could result in an eye injury or blindness. WARNING: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure. Fast Ethernet Fiber to Fiber Media Module Installation Guide 14

Warranty / Registration Perle s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage. Details can be found at: http://www.perle.com/support_services/warranty.shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center (PTAC) can be found at the link below. A Technical Support Query may be made via this web page. www.perle.com/support_services/support_request.shtml Copyright 2017 Perle Systems Limited All rights reserved. No part of this document may be reproduced or used in any form without written permission from Perle Systems Limited. Fast Ethernet Fiber to Fiber Media Module Installation Guide 15