Examples this section is intended to be read in conjunction with the Introduction

Similar documents
The TSL Tally and UMD Configuring Program. Examples this section is intended to be read in conjunction with the Introduction

Mixer Connection Details

Mixer Connection Details

TallyMan UMD & Tally Systems

(((((((((<<<<<<<<<<<<<<<<<<<<Q

TallyMan UMD and Tally Systems

AMU2-2MHD+ Audio monitoring Unit

MV-8 Series & MV-Flex Multiviewers Integrated and Standalone Options for Every Operation

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

AVMU2-BHD+/3G Audio monitoring Unit

MV-8 Series & MV-Flex Multiviewers Integrated and Standalone Options for Every Operation

Sirius 800. Hybrid SDI, Audio & IP routing to 12G, with unrivalled processing & multiviewer capability. 4K Routing 12G SDI. 40/50GbE ST2110 IP routing

FRONT WIRING DIAGRAM FOR ProCommander 2Series

AMU1-BHD+ Audio monitoring Unit

Using SignalTap II in the Quartus II Software

application note Indigo AV Mixer

C8188 C8000 1/10. digital audio modular processing system. 4 Channel AES/EBU I/O. features. block diagram. 4 balanced AES inputs

4040C COMMUNICATION MODULE

Using Virtual GPIO in Axia iq and Radius consoles

eyeheight dk3 SDI luminance keyer user manual

IP LIVE PRODUCTION UNIT NXL-IP55

4-in-1 Motor Controller CAN

C8000. switch over & ducking

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

4X70 PROFINET SYSTEM

RCP Manual. Congratulations! RCP Version 1.0

Infrastructure Applications Broadcast Fibre Optic Solutions

AMU2-8HD+ & 3G Audio Monitoring Units Handbook TSL Vanwall Road, Maidenhead, Berkshire, SL6 4UB

MX-AIR : THE PERFECT TOOL FOR SWITCHING AUDIO & VIDEO

EN TECHNICAL MANUAL. Audio/video module for 2-wire system Art / 1621VC. Passion.Technology.Design.

HDMI-8x8. MicroQ User Manual APANTAC LLC, 7556 SW BRIDGEPORT ROAD, PORTLAND, OR TEL: , FAX:

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

The GTP-32 Control Processor helps you solve equipment interface, control and monitoring problems, quickly and easily

C ch optical MADI & AoIP I/O. MASTER mode: A C8000 frame may be clocked via MADI input or AES67 network. AoIP Dante Brooklin II OEM module

TBS8030 HDMI Encoder User Guide

MASTERPIECE USER MANUAL

ADPCM Voice Compression Options for Sprint 2 TDM

Outside Broadcast Applications Broadcast Fibre Optic Solutions

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

The New Reference Standard is Here!

SignalTap Analysis in the Quartus II Software Version 2.0

ATEM ToolKit (for ATEM Production Switchers)

This document describes the different ways to allow the automation system to close a gpi contact from the transmission list.

Dimming actuators GDA-4K KNX GDA-8K KNX

ATEM Television Studio Pro HD

BROADCAST PRODUCTION\MASTER CONTROL SWITCHERS

Users Manual Firmware 2.03 September 6, 2017

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

Users Manual Firmware 3.03 May 9, 2018

2070 PROFINET MODULE

IP LIVE PRODUCTION UNIT NXL-IP55 USO RESTRITO. OPERATION MANUAL 1st Edition (Revised 2) [English]

HD A/V MATRIX SWITCHER HDMX-1104

NewTek SX-SDI Serial Digital Switcher INSTALLATION

UHF REMOTE RECEIVER INSTALLATION & PROGRAMMING

Embedded Master Module

3Gb/s, HD, SD quad split to WUXGA converter / multiview building block with timecode input COPYRIGHT 2011 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED

Phone: or Website:

E NSEMBLE. Carbon. Analog video interface for Silicon Graphics O2. User Manual. Software Version: v Date of Publication: 5/98 rev.

EEG A1452 SCTE-104 Inserter Frame Card

Smart Control SC16 3-Channel for matrix

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

LCS-2. Low Voltage Lighting Control Relay Processing Panel. Operator s Manual

AVM-T-MIX and AVM-T-MIX SD. Touch Series Audio Monitoring Unit. Handbook Version One

AV-3G-XMUX User Manual

BSM Evolution USB - Compact ON AIR console. BSM Evolution USB. AEV On Air compact broadcast console

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

X-Panda User s Guide

User Guide. MonitorMix User Guide 1

CROSSPOiNT was founded in His founder s expertise soon allows the company to start designing equipments to improve the production process in TV

MD-QUAD VERSION 3 1 to 4 Channel (3G/HD/SD)-SDI Multi-Viewer / Quad-Split with SDI and HDMI outputs Operating Manual for Firmware Version 2.

Feature Descriptions INDEX

Combo Board.

Tebis application software

Model 4455 ASI Serial Digital Protection Switch Data Pack

SIERRA VIDEO. Sierra View SM-xx Multi-Viewer Models: SV-SM-8, SV-SM-12 and SV-SM-16. User s Manual

New Products and Features on Display at the 2012 IBC Show

E-1 Digital Control Surface Technical Guide

Copyright 2013 ACURA Global. UHF860 RFID READER. User s manual. English draft TM970180

ARRI AMIRA. Multi Camera Setup WHITE PAPER DRAFT. Date: October 11, 2018

RELEASE NOTES. Introduction. Supported Devices. Mackie Master Fader App V4.5.1 October 2016

VHF & UHF REMOTE RECEIVERS INSTALLATION AND PROGRAMMING INSTRUCTIONS MODEL NUMBERS TMP-5414 & TMP 5428

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

UTAH 100/UDS Universal Distribution System

HD/SD Three-Layer Logo Keyers

Breaker-and-a-half Automatic reclosing and leader follower.

CULT. Connection diagram. PC Installer application. 1. General principle. 2. Overview. CULT: PC Installer application EN1.5

ATEM Television Studio HD

SAC6840N 2X1 Switcher USER MANUAL

PRODUCTS. Most precise. State-of-the-art. Future proof. BROADCAST DISPLAYS

Supplement to the Operating Instructions. PRemote V 1.2.x. Dallmeier electronic GmbH. DK GB / Rev /

SIPROTEC 5 Application Note

MODULAR I/O DIGITAL AUDIO CONSOLE. Flexible. Affordable. Built To Last.

ControlSpace Designer software 5.1

DA CHANNEL AES AUDIO MIXER/ ROUTER MODULE

BecauseRFL andhubbel haveapolicyofcontinuousproductimprovement,wereservetherighttochangedesignsandspecificationswithoutnotice.

PRODUCT MANUAL. Product Description. Waterproof 4 Channel DMX to RGB-W LED Controller

Wilo WZC Universal Zone Control Installation and operating instructions

33 Really Good Reasons To Choose A Ross Carbonite

NV5100MC. Multi-channel, HD/SD master control switching and branding system. Master control switching and channel branding

ADE-60 4:4 MIX UTILITY

Transcription:

The TSL Tally and UMD Configuring Program Examples this section is intended to be read in conjunction with the Introduction Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299 Revised 27/09/06 1 Examples

Examples 1.0 Mapping one Direct Tally to a UMD to light both LEDS 2.0 Mapping a System Tally to a UMD to light both LEDS independently. 3.0 Mapping a Permanently ON System Tally to the Mixer and outputting tallies to a camera. 4.0 A 2 x 1 Emergency C/O Router Examples 2 Revised 21/11/05

1.0 Mapping one Direct Tally to a UMD to light both LEDS A tally from a Parallel I/O has been named Cam 1 Red. The Tally Channel to which it has been assigned is 1 with the Name: Program/Red Tallies. This tally has been mapped to this UMD as a Direct Tally in the Direct Tally Assignment dialog box. It will be seen that the UMD s Left Tally Channel Mask is set to accept tally channel: Program/Red Tallies. The settings for the Right Mask are the same. Tally 1 will light both the LH and RH tally lamps on the UMD. Revised 27/09/06 3 Examples

2.0 Mapping a System Tally to a UMD to light both LEDS independently. Tally Channels derived from a Parallel I/O are flagged as Tally Channel 2: Iso 1 and Tally Channel 3: Iso 2. The System Tally A System Tally may consist of two of these tallies. Next, add Tally 2 and Tally 3 to System Tally 1. The Active Tally Out Channels must also be set to Iso 1 and Iso 2. System Tally 1 is made up of two I/P tallies, Tally 2 and Tally 3, assigned to Tally Channels named Iso 1 and Iso 2. The Active Tally Channel Mask is set to allow these tallies through. The UMD dialog box System Tally 1 is assigned to the UMD but the Mask has been set to accept Iso1 for the Left Tally and Iso2 for the Right Tally. Separate left and right tallying is now possible via a System Tally. Examples 4 Revised 21/11/05

The UMD Tally Channel Masks The Left and Right Masks set to accept the desired active tally channel, Iso 1 or Iso 2. This will give individual control of the left and right tally LEDs. 3.0 Mapping a Permanently ON System Tally to the Mixer and outputting tallies to a camera. Main Router Vision Mixer Permanently ON System Tally If a permanently ON System Tally is set to a Mixer s PGM O/P it is possible to map this all the way back to the tally O/P pin for connection to a camera s CCU. The idea is that once mapped, selecting any mixer source will send a tally to the correct camera etc. An extension of this idea is that if a prime router O/P might need be taken to air as an emergency O/P, provided that a tally has been set to the router s destination, all cameras etc will receive correct tally signals. Please see the next section. Revised 27/09/06 5 Examples

Create the Permanently ON System Tally. Select an Active Tally Channel Mask box. Go to the Mixer PGM Destination dialog box. Add a Direct Tally in the System Tally. A permanent tally is now set to the Mixer s PGM bus. Examples 6 Revised 21/11/05

Map (assign) the Mixer I/P(s) to the correct Router Destination(s). Map the Router s Source to a physical O/P pin. Router Source 1 Map this source to a Parallel I/O output pin. A CTD-1E is used here. Revised 27/09/06 7 Examples

Adding the selected tally to the output. Ensure that the Active Tally Out Channel matches the Tally Channel assigned to the original System Tally. A tally will now appear on the hardware pin which may be wired to the camera s CCU. Examples 8 Revised 21/11/05

4.0 A 2 x 1 Emergency C/O Router A TallyMan module may be set up which allows tally information to be routed from the transmission o/p back to the router sources and then out to cameras etc. in the event of a mixer malfunction as well as the ability to show the correct source mnemonic that is on-air. Please bear in mind that the drawings give a systems overview from the TallyMan viewpoint. 2 x 1 Emergency Router in TallyMan From Mixer PGM UMD Source 1 Router Source 2 Emergency Router Bus Activating GPI Tally i/p from a parallel I/O Assign this tally to the router s bus A tally set to Source 2 will switch the Emergency 2 x 1 Router to Source 2. The non tallied state is a default to Source 1. If Router sources are connected to the Tally Outputs of a Parallel I/O in TallyMan, tallies may be taken to cameras etc. An external C/O switch to select between Mixer and Router O/Ps. External Switch This could be a simple switch or a GPI from a physical 2 x 1 router. One pole needs to carry out the External Tally control. Possibly a permanently On tally for the mixer PGM Bus. Activating Tally i/p to TallyMan Controller Revised 27/09/06 9 Examples

Examples 10 Revised 21/11/05