VIPA Accessories. ProfiHub B BE00 Manual

Similar documents
MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Level Measurement silometer FMC 420, FMC 423

MICROMASTER Encoder Module

Fibre Optic Modem ODW-611

Operating instructions

ERbic Bus Interface Connector System. Catalog E /06 Edition 4

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

Trusted 40 Channel 120 Vac Digital Input FTA

ODW-621. RS-232 Point-to-point applications

PicoScope 2000 Series PC Oscilloscopes

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Trusted 40 Channel 120 Vac Digital Input FTA

User Manual KUNBUS-PRS

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

EGM Einthoven Goldberger Module Type 701

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Modular DAA with 2/4 Wire Convertor. XE0002D Block Diagram

Fibre Optic Modem ODW-622

SIMATIC. ET 200S distributed I/O IM151-1 BASIC interface module (6ES7151-1CA00-0AB0) Preface. Properties 1. Parameters 2. Error and system messages 3

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

EA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE SINGLETURN ABSOLUTE ENCODERS EA PROFIBUS

I/A Series Hardware Fiber Optic LAN Converter

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Process transmitter RMA422

E3/DS3 Fibre Extender

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

Gamma instabus. Technical product information

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

Fibre optic router for TP/FT-10 LRW-112PP

Mains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.

LONWORKS Fibre Optic Router

Telemetry Receiver Installation Guide

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Capacitance Level Measurement Electronic insert FEC 12

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk1

GV 460 / GV 461 Impulse Splitters for Incremental Encoders with Potential Separation between Input and Outputs

Process Transmitter RMA 422

LONWORKS Fibre Optic Converter

Marshall Electronics. Broadcast A/V Division VAC-HT12-KIT. 4K HDBaseT Extender Kit. User Manual

Capacitance Limit Detection nivotester FTC 420/421/422

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

DCP100 Digital Control Programmer Specifications

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

OM2000N INSTALLATION MANUAL

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

HD1-LX HDMI & IR Extender

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Absolute Encoders Multiturn

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

HP SMA BFOC. Brief instruction. Version. 4en.

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1

Long Range Ethernet Extender

Document Part Number: Copyright 2010, Corelis Inc.

Rack mounted telephone- and leased line modem for industrial applications

MS2540 Current Loop Receiver with RS485 Communication

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Siemens Industry Online Support

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

X4 Process Controller

4, 8, 16 Port VGA and Audio Extender / Splitter with Audio over Single CAT5

DMX-Splitter 4. User Manual

Electrical connection

VGA to DVI Extender over Fiber SET

1x12 VGA & Audio over CAT5 Splitter

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

MultiView T4 / T5 Transmitter

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

Product model and standard

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

One channel video link With duplex data and contact closure

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

User Manual. SCR Multiswitch Ref. 9744SKY, 9746SKY, 9748SKY

Trusted 40 Channel Analogue Input FTA

Transcription:

VIPA Accessories ProfiHub B5 973-5BE00 Manual HB151E Rev. 12/04 January 2012

Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or used except in accordance with applicable agreements. This material is protected by the copyright laws. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to VIPA), except in accordance with applicable agreements, contracts or licensing, without the express written consent of VIPA and the business management owner of the material. For permission to reproduce or distribute, please contact: VIPA, Gesellschaft für Visualisierung und Prozessautomatisierung mbh Ohmstraße 4, D-91074 Herzogenaurach, Germany Tel.: +49 (91 32) 744-0 Fax.: +49 9132 744 1864 EMail: info@vipa.de http://www.vipa.de Note Every effort has been made to ensure that the information contained in this document was complete and accurate at the time of publishing. Nevertheless, the authors retain the right to modify the information. This customer document describes all the hardware units and functions known at the present time. Descriptions may be included for units which are not present at the customer site. The exact scope of delivery is described in the respective purchase contract. CE Conformity Hereby, VIPA GmbH declares that the products and systems are in compliance with the essential requirements and other relevant provisions of the following directives: 2004/108/EC Electromagnetic Compatibility Directive 2006/95/EC Low Voltage Directive Conformity is indicated by the CE marking affixed to the product. Conformity Information For more information regarding CE marking and Declaration of Conformity (DoC), please contact your local VIPA customer service organization. Trademarks VIPA, SLIO, System 100V, System 200V, System 300V, System 300S, System 400V, System 500S and Commander Compact are registered trademarks of VIPA Gesellschaft für Visualisierung und Prozessautomatisierung mbh. SPEED7 is a registered trademark of profichip GmbH. SIMATIC, STEP, SINEC, S7-300 and S7-400 are registered trademarks of Siemens AG. Microsoft und Windows are registered trademarks of Microsoft Inc., USA. Portable Document Format (PDF) and Postscript are registered trademarks of Adobe Systems, Inc. All other trademarks, logos and service or product marks specified herein are owned by their respective companies. Information product support Contact your local VIPA Customer Service Organization representative if you wish to report errors or questions regarding the contents of this document. If you are unable to locate a customer service center, contact VIPA as follows: VIPA GmbH, Ohmstraße 4, 91074 Herzogenaurach, Germany Telefax:+49 9132 744 1204 EMail: documentation@vipa.de Technical support Contact your local VIPA Customer Service Organization representative if you encounter problems with the product or have questions regarding the product. If you are unable to locate a customer service center, contact VIPA as follows: VIPA GmbH, Ohmstraße 4, 91074 Herzogenaurach, Germany Telephone: +49 9132 744 1150 (Hotline) EMail: support@vipa.de

Manual VIPA Accessories Contents Product ProfiHub B5 Order number VIPA 973-5BE00 The information contained in this manual is supplied without warranties. The information is subject to change without notice. Icons Headings Important passages in the text are highlighted by following icons and headings: Danger! Immediate or likely danger. Personal injury is possible. Attention! Damages to property is likely if these warnings are not heeded. Note! Supplementary information and useful tips. HB151E - Rev. 12/04 1

Contents Manual VIPA Accessories Contents Contents... 2 Product description... 3 Installation... 8 Technical Data... 13 Important Safety Information for users Handling of electrostatic sensitive modules VIPA modules make use of highly integrated components in MOS- Technology. These components are extremely sensitive to over-voltages that can occur during electrostatic discharges. The following symbol is attached to modules that can be destroyed by electrostatic discharges: Attention! Personnel and instruments should be grounded when working on electrostatic sensitive modules! 2 HB151E - Rev. 12/04

Manual VIPA Accessories Product description Product description General The ProfiHub B5 PROFIBUS DP repeater in a IP20 casing for industrial automation, to implement long multi-device spur lines and backbone structures with star/tree segments for PROFIBUS DP. PROFIBUS DP is a high speed communication bus that has to comply with strict rules concerning spur lines, because of possible reflections that could lead to communication disturbances. It has the functionality of 5 galvanic isolated transparent repeaters. This allows network structures with extended spur lines that individually can handle a maximum of 31 devices and a length equal to the main bus. The ProfiHub B5 refreshes a received message on one channel and transfers it to all the other channels. Because the ProfiHub B5 creates isolated segments, the devices can now be removed and added during operation. Also electrical bus problems and EMC disturbances in a spur do not spread to the other segments. The intelligent logic and isolation circuits of the ProfiHubs do not change the bit width. This means the ProfiHubs do not have limitations in serial placement. The logic also detects the transmission speed automatically. To assist the installation work, termination is integrated and can be switched on/off. The grounding concept is also selectable: direct or capacitive grounding. The ProfiHub B5 is to be powered by DC 10...32V. For troubleshooting, maintenance and commissioning there are LEDs at the front side of the ProfiHub B5 Order data Type Order number Description ProfiHub B5 973-5BE00 5 channel PROFIBUS DP Repeater HB151E - Rev. 12/04 3

Product description Manual VIPA Accessories Features 5 Galvanic isolated channels (repeater segments). Transparent for all PROFIBUS DP protocols DP - RS 485 specifications for each channel. 9.6kbps to 12Mbps 31 devices per channel 1200 m spur line length (depends on transmission speed) No limit in serial placement or cascading of ProfiHubs No PROFIBUS address required Integrated termination facilities (switches) Configurable grounding system (direct or capacitive). IP 20 classification (according to DIN 40 050) Application areas Dynamic spur lines to actuators, flow meters and ph analyzers. Removable drives and motors Pull/Plug motor control centers (drawers) Roof mounted devices in tank farms Dirty and humid environments Barrier for non galvanic isolated equipment Large star/tree structured networks 4 HB151E - Rev. 12/04

Manual VIPA Accessories Product description Additional Benefits Hot slave insertion and removal during operation Short circuit protection on each channel Compact and robust construction Status and error display (per channel) Suitable for all DP cables Conveniently arranged networks Easy extendable installations Channel structure Every channel is electrically isolated and internally connected to the transparent intelligent backbone. The termination is switchable and powered by the ProfiHub. The shielding of the PROFIBUS cable can be directly grounded or indirectly grounded. RX-OK ERROR Powered Termination Intelligent Backbone Isolation circuit RS485 circuit A B PROFIBUS DGND I Indirect grounding C C Direct grounding Isolated area direct grounding of other channels HB151E - Rev. 12/04 5

Product description Manual VIPA Accessories Grounding System The ProfiHub can be grounded by 3 methods: Direct grounding Indirect grounding (through a capacitor) Combination of direct and indirect In most cases it is recommended always to use Direct Grounding with the power supply and the shielding of the PROFIBUS cables. If you do not want to ground all or some cables to the common ground, the cable shielding should be connected to pin "I". A capacitor with a parallel high value resistor will separate the 2 potentials. If by accident on 1 channel the Direct Grounding is connected with the Indirect Grounding, the Direct Grounding wins. Cable length for PROFIBUS DP The cables on the channels and the Main Channel should comply with the PROFIBUS DP cable specifications for RS485. Baudrate (kbit/s) 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Segment length (m) 1200 1200 1200 1200 1000 400 200 100 100 100 Segment length (feet) 3940 3940 3940 3940 3280 1310 656 328 328 328 Cable types for PROFIBUS DP The cable type should comply with the PROFIBUS DP cable specifications for RS 485. Parameter Wires Impedance Capacity Loop resistance Wire diameter Wire area Value 2 (twisted) 150Ohm (3... 20MHz) < 30pF/m < 110Ohm/km > 0.64mm > 0.32mm 6 HB151E - Rev. 12/04

Manual VIPA Accessories Product description Diagnostic LEDs LED Color Description Power green Power is not switched on or an internal failure Power supply not stable or an internal failure Power supply OK READY green Power is not switched on or an internal failure Trying to detect the transmission speed, but has not locked it yet The transmission speed has been detected Main green No communication detected on the Main Channel RX-OK 1 or more devices communicating on the Main Channel 1 or more devices communicating on the Main Channel Main red No problem has been detected ERROR Problem in the cabling has been detected (Main Channel) Problem in the cabling has been detected (Main Channel) Main yellow Termination off (Main Channel) INT. TERM. Termination on (Main Channel) Channel green There is no communication detected (on this channel) RX-OK 1 or more devices communicating (on this channel) 1 or more devices communicating (on this channel) Channel red No problem has been detected ERROR Problem in the cabling has been detected (on this channel) Problem in the cabling has been detected (on this channel). Channel yellow Termination off (on this channel) INT. TERM. Termination on (on this channel) off: blinking: on: HB151E - Rev. 12/04 7

Installation Manual VIPA Accessories Installation Location The ProfiHub B5 can be installed everywhere in a non-hazardous area that complies with IP 20 (DIN 40 050) and the specified temperature range of -20 to +75 o C. Position The ProfiHub B5 can be installed in every position, but it is recommended to install it with the cables pointing down. In this position it is also easier to read the status display. Mounting The ProfiHub B5 has to be mounted on 35mm DIN rail with a minimum width of 167mm. Power Supply The 3-pole screw type power connector is located on the bottom left of the ProfiHub B5. PIN Wiring + + - - I Indirect grounding The power supply has to comply with the following specifications: Voltage: DC 10... 32V Current: Min. 130mA Wire diameter: < 2.5mm² Procedure To connect the 24V supply to the 3-pole screw-type terminal, proceed as follows: Strip the insulation from the cable or the conductors for the 24V power supply. Secure the conductors in the screw-type terminal Note! There is a grounding point that can be used. To connect the power supply, you need a 3mm screwdriver. Diagnose If the power is switched on it can be diagnosed by the following indicators: All the LEDs should be shortly blinking. The POWER LED is ON. The READY LED is ON or blinking. 8 HB151E - Rev. 12/04

Manual VIPA Accessories Installation Note! It is recommended to use a power supply with a ground lead (3-wire). Backbone Connect the DP backbone cable to the bottom-left connector of the Main Channel. If the ProfiHub is not the last device on the bus segment, connect the Bus-Out cable to the right connector of the Main Channel. The second method is to place a PROFIBUS standardized plug with an in/out cable on the DB9 connector. Communication status LEDs DB9 Bus In-/Out-Connector Bus-Out Connector Bus-In Connector Pin layout PIN (Clamp) A B I Wiring green wire red wire Cable shielding or Cable shielding LED If the Main Channel recognizes valid PROFIBUS messages from 1 or more connected devices, the RX-OK LED of this channel should be blinking. HB151E - Rev. 12/04 9

Installation Manual VIPA Accessories Spur segments Connect the spur segments to the connectors of channel 1 to 5. The second method is to place a PROFIBUS standardized plug on the DB9 connector of the specific channel. Communication status LED Channel 1 Channel connector Channel 1 Channel connector Channel 1 Pin layout Pin (Clamp) A B I Wiring green wire red wire Cable shielding or Cable shielding Note! Connecting the cable shielding is not required when the ground clips are used. LED If the Main Channel recognizes valid PROFIBUS messages from 1 or more connected devices, the RX-OK LED should be blinking. 10 HB151E - Rev. 12/04

Manual VIPA Accessories Installation Termination The termination of the Main Channel has been set to OFF by default. If the ProfiHub is the last device on the bus, the termination should be set to ON. The termination of the channels have been set to ON by default. Because it is assumed that the new segment is started at the ProfiHub. Termination LED Main Channel Termination Main Channel The termination LED of the specific channel is activated when the termination switch is set to ON. Note! When the DB9 connector is used and the cable starts at the ProfiHub, it is recommended to use the termination on the DB9 plug and NOT the ProfiHub. HB151E - Rev. 12/04 11

Installation Manual VIPA Accessories Baudrate switch The ProfiHub B5 recognizes the transmission speed by default. If it is required that the ProfiHub B5 is locked to a certain transmission speed, the baudrate switch should be set to the required value. Baudrate speed switch Settings Values 0 Auto detect (Default) 1 9.6kbps 2 19.2kbps 3 45.45kbps 4 93.75kbps 5 187.5kbps 6 500kbps 7 1500kbps 8 3000kbps 9 6000kbps A 12000kbps B... F Auto detect Note! To set the transmission speed, you need a 3mm screwdriver. 12 HB151E - Rev. 12/04

Manual VIPA Accessories Technical Data Technical Data Order number Type Dimensions and weight Dimensions (LxWxH) in mm Weight Environmental conditions Operating temperature 973-5BE00 ProfiHub B5 167x111x32 (with screws) 650g -20 to +75 C Isolation class IP 20 (DIN 40 050) Protocol specifications Supported protocols Transmission speed Transmission speed detection Transmission speed switch Data delay time Delay time jitter Specification PROFIBUS cable Cable lengths DP-V0, DP-V1, DP-V2, FDL, MPI, FMS, PROFIsafe, PROFIdrive and any other protocol auf FDL-Basis 9.6kbps to 12Mbps (including 45.45kbps) Auto detect (default) or settable with a rotary switch < 10s (if it set to auto detect) 1.25Tbit at 9.6kbps to 93.75kbps 1.3Tbit at 187.5kbps to 500kbps 1.4Tbit at 1.5Mbps 1.6Tbit at 3Mbps 2.0Tbit at 6Mbps 3.0Tbit at 12Mbps Max. 1/4 bit time 1200m at 9.6kbps to 93.75kbps 1000m at 187.5kbps 400m at 500kbps 200m at 1.5Mbps 100m at 3Mbps to 12Mbps 10mm (when the ground rail is used) Cable thickness Wire diameter < 2.5mm 2 Wire type Stranded or solid core Number of devices max. 31 per channel (including ProfiHubs, OLMs, PCs) Termination Integrated and switchable Powered according to IEC 61158 (390/220/390 Ohm) - all channels (default on) - main channel (default off) Cascading depth no limits Redundancy no Power supply specifications Nominal supply voltage DC 10... 32V Current consumption 130mA at DC 24V power supply (all channels fully loaded) Power dissipation max. 4.1W HB151E - Rev. 12/04 13

Technical Data Manual VIPA Accessories Reverse polarity protection Cable thickness yes Wire diameter < 2.5mm 2 Others MTBF 10mm (when the ground rail is used) 398723 hours according to IEC62380 (RDF-2000 / UTE C 80-810, mathematical model for failure rates). 14 HB151E - Rev. 12/04