INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

Similar documents
F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

(Non-Radioactive Surge Arrester) OPERATION MANUAL RS232 TO RS485/RS422 BOX CHAPTERS APPENDICES. A. Warranty Information.. 11

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

TC3005(LED/ELED/LASER) User's Manual

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. June 2015 Part Numbers FIBER DRIVER

Mini HD-SDI Optical Transceiver Model No : VCF-MF01TXRX

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

TC1630. T1/E1 FIBER OPTIC MODEM User's Manual

ASP-FIBRS1 User Manual

MODEL 2873 Chassis with RS422 CLOCK RECOVERY Module, IOCRM4

TC3301. User's Manual

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

I N S T R U C T I O N D A T A

Instruction Manual RT-91600D-SL RR-91600D-SL Sixteen Channel Video Multiplexer With Remote Diagnostic Interface

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

PSM-003. Micro Polarization Controller/Scrambler. User Guide

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

VersiVision. FVTM2BBxA / FVRM2BBxA 2-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA 2-CHANNELS BI-DIRECTIONAL AUDIO

Single mode 9/125µm, duplex

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

VersiVision. FVTMHA0xA / FVRMHA0xA 16-CHANNEL DIGITALLY ENCODED VIDEO 1-CHANNEL BI-DIRECTIONAL DATA MULTIPLEXER USER S MANUAL.

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

Fiber Converters TFC-1000 Series. ŸQuick Installation Guide (1) ŸTechical Specifications (4)

FiberLink 3350 Series

12G/6G/3G/HD/SD-SDI over Single mode SFP-type Fiber Optic Extender Immune to Pathological. User Manual. rev: Made in Taiwan

RS-232 to Multi-Mode Fiber Optic Media Converter

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

Synchronous Fiber Optic Modem

instruction manual model 315 video sync separator s/n

VGA to DVI Extender over Fiber SET

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

DA8-T DA8-T MANUAL

Fiber Converters TFC-110 Series. ŸQuick Installation Guide (1)

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL


USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)

Perle Fast Ethernet Media Converters

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

VCF-HCFB01TXRX SD/HD/3G-SDI Optical Transceiver with Independence audio

PRO-CoaxExt HDMI extender over Coaxial cable with bi-directional IR User s Guide

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PHOX TM. Camera Link Fiber Extender. Base Configuration KEY FEATURE APPLICATIONS PHOX-BM PHOX-BL-10/20/40/50

BRIGHTLINK HDMI EXTENDER OVER ETHERNET - H METER MODEL: BL-EXT-IP-264

Model 5240 Digital to Analog Key Converter Data Pack

FOM-9010, FOM-9011 and FOM-9012

HD/SD-SDI to HDMI adaptor board HD-3000S Manual

Functional Diagram: Figure 1 PCIe4-SIO8BX-SYNC Block Diagram. Chan 1-4. Multi-protocol Transceiver. 32kb. Receiver FIFO. 32kb.

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

R20CE 10-bit Encoder. R-series Card Module User Manual. August 25, 2003 P/N

ECT5484. Fiber Optic Digital Video, Audio & Data Multiplexer/Demultiplexer. Single Fiber Operation. Specifications

FiberLink 3500 Series Transceivers

H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 WolfPack Operating Instruction

Perle Fast Ethernet Media Converters

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

H m HDMI Wallplate Extender over IP

H.264 HDMI Extender over IP Extender With LED, Remote, RS232. Operating Instruction

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

8 Port HD/SD-SDI Switch

Ethernet Media Converters

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

Model /29S RF Splitter

SignalTap Plus System Analyzer

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

LBO-HDMI-AD LINK BRIDGE TM FIBER OPTIC HDMI VIDEO CONVERTING TRANSMITTER SYSTEM

INSTRUCTION MANUAL. FiberSaver Series, FS-6000, FS-12000, FS-18000

SD/HD/3G-SDI Video + Power + Data RS-485 Transmission over Coax Kit

GFT Channel Digital Delay Generator

J C F A U D I O AD8 MANUAL 1.4 JCF AUDIO, LLC CAMARILLO ST. NORTH HOLLYWOOD, CA

TranScend Opto-Stacker & Destacker. Operation Manual

Agilent E4430B 1 GHz, E4431B 2 GHz, E4432B 3 GHz, E4433B 4 GHz Measuring Bit Error Rate Using the ESG-D Series RF Signal Generators, Option UN7

3-DRX. AUTOMATIC THREE CHANNEL DIGITAL AES/EBU REPEATER and ANALOG AUDIO SWITCHER INSTALLATION AND OPERATING MANUAL

3G fiber. TL7075/76 Optical 3Gbit/s Link solution with full duplex Communication Channel. TL Features. TL Features

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

Model 7600 HD/SD Embedder/ Disembedder Data Pack

o-microgigacn Data Sheet Revision Channel Optical Transceiver Module Part Number: Module: FPD-010R008-0E Patch Cord: FOC-CC****

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

Laboratory 4. Figure 1: Serdes Transceiver

Content. 3G SDI 4X1 Switcher 1 INTRODUCTION. 1 2 SPECIFICATION PACKAGE CONTENT PANEL DESCRIPTION CONNECTION AND OPERATION..

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

Warnings and Precautions

instruction manual Model 619YY video dual vertical line generator s/n

FiberLink 3355 Series

USER MANUAL MODEL 2701/B, C, D. G.703/G.704 NTU with EIA-530, V.35, X.21 Interfaces SALES OFFICE (301) TECHNICAL SUPPORT (301)

LONWORKS Fibre Optic Converter

PAD-2 2 Channel A-D Converter Mk2 Rev. 3 Sept. 24, 2017

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

Analog HD video over fiber converters for smart HD CCTV

16-BIT LOAD CELL/DUAL STATUS INPUT

32 Channel CPCI Board User Manual

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

Transcription:

210 South Third Street North Wales, PA USA 19454 (T) 215-699-2060 (F) 215-699-2061 INSTRUCTION MANUAL FOR LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE i

TO THE CUSTOMER Thank you for purchasing this equipment from APOGEE LABS, Inc. Our intention is that the equipment meets your requirements and exceeds your expectations and you find our documentation adequately describes its operation and use. We continue to strive for higher levels of quality in our products, services and customer support and look forward to hearing from you if you have any comments or questions regarding these areas. We sincerely believe that the customer comes first. WARRANTY APOGEE LABS, Inc. warrants its products to be free from defects in materials and workmanship for a period of 18 months from the date of shipment to the original purchaser. APOGEE LABS Inc. obligation for any defect shall be limited to repair or replacement at our discretion of defective equipment. APOGEE LABS, Inc. assumes no liability if defects result from improper use, repairs not made by APOGEE LABS, Inc., negligence, accident, mishandling or misapplication of the equipment. No other warranty is expressed or implied and APOGEE LABS, Inc. assumes no liability for consequential damages. Should a warranty repair be required, please contact APOGEE LABS, Inc. for a Return Authorization Number. EXTENDED WARRANTY APOGEE LABS, Inc. offers an extended warranty plan to cover equipment beyond the normal Eighteen (18) month warranty plan. Under the extended warranty, APOGEE LABS will repair or replace equipment and/or components which have failed under normal use at its sole discretion. This extended warranty does not cover repair or replacement of equipment or components that failed because of improper use, repairs not made by APOGEE LABS, Inc., negligence, accident, misapplication of the equipment, or mishandling. A one-year or multi-year Extended Warranty may be purchased. Please contact our sales department for a price quotation. ii

Table of Contents Description Page Number Module Overview Features 1 Overview 1 Configuration 1 Input Termination 2 Input / Output Polarity 2 Operation 3 Data Clock Relationship 4 LED Status Indicators 4 Specifications 5 Application Information 5 iii

FEATURES IOC534TX serial TTL data and clock input (fiber out) IOC534RX serial TTL data and clock output (fiber in) 100 bps to 20 Mbps data rate Asynchronous Data only mode up to 9 Mbps Less than 1/2 bit period plus 100 ns latency input to output using 1 meter fiber cable Channel to channel skew <20ns Less than 1ns induced jitter Instantaneous acquisition Multiple fiber mode and connectors available Single fiber moves both data and clock signals Provides electrically isolated link Input code - NRZ-L, NRZ-M, NRZ-S, RNRZ-L Input Clock, 0 degree or 180 degree clock Output Code - NRZ-L, NRZ-M, NRZ-S, RNRZ-L (same as input does not translate) Output Clock: 0 degree clock OVERVIEW The IOC534 Pluggable Interface Module (PIM) provides the ability to transfer serial signals over a fiber optic cable with very low latency. These modules may be used to provide a DC isolated data link, a medium length (up to 10km standard) data path, and also to reduce radiated emissions. The transmitter accepts a serial synchronous data stream (data and clock) and converts it to an optical signal for transmission over single mode fiber optic cable. The encoded data is received by the receiver module, which converts the optical signal back to its original data and clock form. The IOC534 uses industry standard BNC connectors. Both operate from 100 bps to 20 Mbps and requires one of the 14 available slots in the 2073 or 2873 chassis. These modules are also supported by the single-slot AL2073-SL chassis. CONFIGURATION When installed in the AL2073/AL2873 chassis, the system functions as a NRZ input to NRZ output system. The data and clock polarity is automatically detected and adjusted to ensure that the data is sampled at a stable portion of the bit period. The IOC534 modules have jumpers that allow the inversion of the input data and clock. The Clock input and output can act as a low to medium rate data transport without the need for a synchronous clock. Connect the asynchronous data signal input to the IOC534TX Clock input connector and connect the clock output connector on the IOC534RX to the data signal destination This provides for a maximum data rate of 9Mbps. 1 of 5

INPUT TERMINATION The IOC534TX provides input termination options for both the data and clock signals. This is done through jumper configuration on the module. See the table below for configuration: Jumper JP4 JP5 Signal Data In Clock In Assignment 1-2: 50 Ohm Termination 2-3: 75 Ohm Termination 3-4: Hi-Z Termination (~30K) 1-2: 50 Ohm Termination 2-3: 75 Ohm Termination 3-4: Hi-Z Termination (~30K) INPUT / OUTPUT POLARITY The IOC534TX provides the ability to invert the incoming data and clock signals. The IOC534RX provides the ability to invert the outgoing data and clock signals. This is done through jumper configuration on the module. See the table below for configuration: Model Jumper Signal Assignment IOC534TX JP1 Data In 1-2: Normal Data Polarity IOC534RX JP2 Data Out 2-3: Inverted Data Polarity IOC534TX JP6 Clock In 1-2: Normal Clock Polarity IOC534RX JP3 Clock Out 2-3: Inverted Clock Polarity The default jumper position from the factory is to have all installed jumpers at location 1-2. Refer to diagram below for jumper location. 2 of 5

OPERATION The IOC534 modules are simple plug and play modules. When placed in a chassis and powered on, they only need to be connected to their proper cable and let them transport their data. IOC534 TX/RX CABLING Synchronous mode In synchronous mode, both the data and clock are transmitted by the user over the fiber optic cable. In this mode the user connects the data and clock to the IOC534TX module s inputs. The fiber optic cable is connected to the TxD port. The fiber optic cable is then run to the IOC534RX module s RxD fiber input. The data and clock are output on the IOC534RX Data and Clk connectors respectively. IOC534TX IOC534RX Asynchronous mode In asynchronous mode, only the data is transmitted by the user over the fiber optic cable. In this mode the user connects the data to the IOC534TX module s clock (Ck) input. The fiber optic cable is connected to the TxD. The fiber optic cable is then run to the IOC534RX module s RxD fiber input. The data is output on the clock (Ck) connector. IOC534TX IOC534RX 3 of 5

DATA / CLOCK RELATIONSHIP The IOC534 modules operate on a 0 degree data and clock relationship. This means that the data transitions while the clock signal transitions from a zero to a one state (rising edge). This ensures the bit detection of the data is stable during the falling edge of the clock. The following image demonstrates this relationship. The IOC534 will detect if the edge alignment is improper and invert the clock to ensure clean data transmission. LED STATUS INDICATORS The AL2073 chassis has status LEDs to indicate status of signals and give an indication of the operation status of the modules. On the AL2073 chassis each slot has two status indicators. SLOT Top LED Indicator Bottom LED Indicator Slot Number Module LED Status Definition IOC534TX IOC534RX Top LED Bottom LED Top LED Bottom LED ON ON ON ON BLINKING Data transitions are seen on the data input connector Clock transitions are seen on the data input connector The fiber optic signal is detected on the fiber RX input Data and clock signals are being output Only clock signals are being output (no data transitions are seen) 4 of 5

SPECIFICATIONS GENERAL IOC534: BNC connectors 1 Slot Module (3 x 6 x 0.9 ) Requires single slot in AL2073/AL2873 chassis ELECTRICAL SIGNAL INPUT IOC534TX: TTL with 50/75Ω termination Supports NRZ Input codes Maximum Data rate 20Mbps (at 50% duty cycle) Min clock edge-edge time: 25ns Automatically detects input data clock relationship ELECTRICAL SIGNAL OUTPUT IOC534RX: TTL (90mA sink/source) Supports NRZ Output codes Output code same as input OPTICAL SIGNAL I/O SC or ST type connector* Single-mode or multi-mode fiber* 1310 nm wavelength 10 km range Minimum optical output power: -9.5dB Maximum receiver sensitivity: -20dB contact sales for longer distances * contact sales for fiber configuration POWER CONSUMPTION IOC534TX: 225mA (at 20 Mbps) IOC534RX: 430mA (at 20 Mbps) ENVIRONMENTAL Operating temperature: 0 to 40 C Relative Humidity: 0 to 95% non-condensing APPLICATION INFORMATION The IOC534 modules transport data over long distances (10km or greater) of fiber optic cable. The IOC534 modules do this with very low latency allowing user data to get to its end point with minimal delay thus removing the variable of delay from being a data transport concern. The IOC534 utilizes industry standards for both the electrical and optical signal interfaces. The units are self adjusting to any data rate within its specified range requiring no operator setup. 5 of 5