Processing Specification MiniBridge IDC

Similar documents
MicroBridge. for Automotive-Applications ED Full-scale MicroBridge Male Connector 6 Pin Catalog E

MiniBridge 1.27 mm Connectors

MaxiBridge mm Connectors. Ed Full-scale MaxiBridge 8 Pins Catalog E

HARTING Ethernet cabling cables and connectors, 4 wire

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz)

ERbic Bus Interface Connector System. Catalog E /06 Edition 4

Cable installation guidelines

Building a MidiBox LCD Cable

Cables for robot applications

CATEGORY 5e CABLING SOLUTIONS

Coaxial Cable Termination

Laying of cables and lines in electrical installations and data networks

Ribbon Cable connector Compliant with MIL Standard

Ribbon Cable connector Compliant with MIL Standard

DIN EUROCARD CONNECTORS

Connectivity for Ethernet

Ribbon Cable connector Compliant with MIL Standard

Connecting cables NEBS, for sensors

Highlights: Cables & Adaptors. Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Connector Adaptors

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

CATEGORY 6 CABLING SOLUTIONS

BUS UNITRONIC BUS CAN

Ribbon Cable connector Compliant with MIL Standard

Continuous Flex Data Cable

4320 SS-25 Self-Strip Terminating Block

OCT 15 Rev B

Connecting cables for valves, round plug connectors Product range overview

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

D-COAX, Inc. D-COAX Male-Female 1501 Series Cables and Cable Pairs. High Frequency, Skew Matched, Phase Stable Cable Pair (40 GHz)

PRODUCT INFORMATION. ETHERLINE EC Flex Cat.5e M8

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Pivot Power RJ45 Modular Plug Connectors

FLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable

0.3 mm Pitch, 1.5 mm Mated Height, Board- to-fine Coaxial Cable Connectors

Connecting cables for valves, Sub-D Type codes

Ribbon Cable connector Compliant with MIL Standard

GT21 Series GT21A Series

MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors. NOT the LATEST REVISION

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Main Products. Cable Assemblies Wire Harnesses Raw Cables. Connectors

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

CATEGORY 6A CABLING SOLUTIONS

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Connectors, self-assembly

PKK PKK CHARACTERISTICS. Dimensions. Travel. Travel speed. Acceleration. Temperature. Special versions APPLICATION AREAS. PLE max.

PL Series. Plastic Push Pull Interconnects

CATEGORY 6A CABLING SOLUTIONS

PKK PKK CHARACTERISTICS. Dimensions. Travel. Travel speed. Acceleration. Temperature. Special versions APPLICATION AREAS. PLE max.

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

HighBand 25. TrueNet Category 6 Solutions

NewScope-7A Operating Manual

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

Rectangular, Multiple-Position Rack/Panel Insulation Displacement Connectors (IDC)

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

Figure 1: Device components

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009

BNC 75 Ohm RF-Connectors

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Multi-Media Installation Guide

Volition TM RJ45 K5e Jacks

Small Circular Connector. JN1/JN2 Series. Dust Cap

Panel-Mounted Thermostat

Adapter Selection. Entry Size (Continued) Table E. Multiplication. factors for wire bundles. with Equal Size Wires. This table provides multiplication

PRODUCT INFORMATION ETHERLINE PN FLEX. Info CPR: Article number choice under For Profinet applications Flexible use

Documentation VFD clock 8 a clock

Magic Patch Patch Leads & Accessories

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

Bus Cables & Industrial Ethernet Cables

3 SLiC Aerial Closure with Rubber End Seal

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

ELECTRONIC CONNECTOR ASSEMBLY TRAINING CERTIFICATION EXAM (DVD-62C) v.1

Product Information. Manual change system SHS

PREMIUM 5e F/UTP PRODUCTS

Instructions. Cable with Armor F CAUTION. October Rev A

MPI Cable Selection Guide

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

Cicoil. Not your father s flat cable

Fiberglass - Technical Data

The Custom Interconnect Leader TM

STRUCTURED CABLING SYSTEMS (SCS)

Medical Application Information

Rectangular, High-Pin-Count Rack/Panel Insulation Displacement Connectors (IDC)

Compact Module. Category 6 FTP Cabling System

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

12G Broadcast connectors

R/C Afterburner Light Kit For Electric EDF Jets 2009 Hyperdyne Labs

Flat Cable. Table of Contents

LED MODULES READYLINE DL

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Connectors, self-assembly


3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

The WINSTA Connection System for Linect Lights

Transcription:

Processing Specification MiniBridge IDC ERNI Electronics GmbH & Co. KG Seestrasse 9 l 73099 Adelberg / Germany l +49 7166 50-0 l www.erni.com Version 5 IMS Verarbeitungsspezifikationen Seite 1 von 11

Table of Contents Fundamentals... 3 Product characteristics... 3 Cable design... 4 Tools... 4 General information... 4 Partially assembled MiniBridge connectors with 0.35 mm² cable cross-section... 5 Processing parameters... 5 Pressing force... 5 Pressing speed... 5 Available tools... 5 Tools for hand lever presses... 5 Lower tools female straight connectors... 6 Lower tools female right angle connectors... 6 Assembly... 7 Position of wire... 7 Right angle cable termination (Type P)... 7 Straight cable termination (Type A)... 8 Flat ribbon cable alignment... 8 Position of the IDC Terminal... 9 Cable guide locking... 9 Visual characteristics... 9 Dimensions... 10 Inspection... 10 Inspection of part characteristics... 10 Electrical inspection... 11 Application Note... 10 Recommendation for cable-laying... 10 Version 5 IMS Verarbeitungsspezifikationen Seite 2 von 11

Fundamentals The acceptance criteria for cable assemblies and cable harness assemblies in the current IPC-A-620 manual is generally recommended for the assembly of ERNI connectors. Product characteristics IDC terminal- connectors of the MiniBridge product family are available in the Standard and Koshiri version. Number of pins 2, 3, 4, 6, 8, 10 and 12 pins Locking Positive lock - red cable guide and latch at the Standard and Koshiri version. Detachable by toll Friction lock - black cable guide and latch at the Standard version. Detachable by hand without tools Standard Koshiri Terminal sizes IDC terminals for the Standard version are available in AWG 26/24 and AWG 22 size IDC terminals for the Koshiri version are available in AWG 22 size Version 5 IMS Verarbeitungsspezifikationen Seite 3 von 11

Cable design The MiniBridge IDC termination meets the requirements of DIN EN 60352-4. Following cables are permissible within that standard: Flat ribbon cables or discrete wire with round solid core or stranded wires with 7 strands are to be used. Stranded wires must have tin-plated (tin or tin-lead) or silver-plated strands. The insulating material must be PVC or a different material that is compatible with the cutting and clamping process. That means, that the complete displacement of the insulation material by the inner termination clamp edges should be possible without damaging the wire. For stranded wires, the cable insulation must additionally be suitable to hold the strands in place, so they can not be inadvertently displaced during the assembly process. When using flat ribbon cables, the insulation material between wires (including each insulation gap belonging to the flat cable design) must be completely displaced by the edge of the ID termination clamp. In addition to DIN EN 60352-4, stranded wires with plain strands are qualified as well. Due to the compact design of the connector, only cables with an outer diameter, which fits into the corresponding cable guide, can be used. Only cables with a maximum outer diameter of 1.07 mm or 1.27 mm, depending on the cable guide, may be processed. The qualification has been successfully performed with the following cable types: Flat ribbon cable: Cable construction AWG 26 with 7 strands, pitch 1.27 UL 2651 (Insulation PVC) UL 21151/1581 (Insulation Polyolefin, halogen-free) Discrete wire: cable construction AWG 26, 7 x 0.14 mm UL 1061 (Insulation PVC, strands tin-plated) UL 1671 (Insulation ETFE, strands tin-plated) Discrete wire: cable construction AWG 24, 7 x 0.22 mm UL 10125 (Insulation ETFE) MIL-W16 878E (Insulation PTFE, strands silver-plated) Discrete wire: cable construction AWG 22, 7 x 0.26 mm UL 10125 (Insulation ETFE, strands tin-plated) Discrete wire: Automotive cable 0.35 mm 2, 7 x 0,26 mm FLU2X 0,35-A (Insulation XPE, strands copper plain) FLU7Y 0.35-A (Insulation ETFE, strands copper plain) Tools General information In order to prevent connector damage from excessive pressure the only tools allowed are those which limit the press-in distance so, that it may not be possible to press below the lower dimension limit. Version 5 IMS Verarbeitungsspezifikationen Seite 4 von 11

Tools need to have sufficient space, so that the locking mechanisms cannot become damaged during the pressing process. Partially assembled MiniBridge connectors with 0.35 mm² cable cross-section There is a variation in the processing of partially loaded IDC connectors using discrete wire with a cross-section of 0.35 mm² (AWG 22). In this case, the only tools and devices permitted for use are those which close the unloaded positions of the cable guide and prevent excessive pressure on the neighboring ID terminal clamps on the plastic body. This preventive operation is not necessary using IDC connectors with smaller cross-sections (AWG 24/26). However, it is an useful action to avoid assembly errors and scrap. Processing parameters Pressing force Depends on cable cross-section and insulation material. Pressing forces up to 100 Newton per contact are necessary for processing MiniBridge connectors. Devices such as hand-lever presses, other types of presses, or machines should be designed accordingly. Pressing speed A maximum pressing speed of 10 mm/s is recommended. Available tools Tools for hand lever presses Basic tool set ERNI Part- No. 501260 consists of upper tool and lower tool holder for assembly on Version 5 IMS Verarbeitungsspezifikationen Seite 5 von 11

hand-lever presses with Ø 10H7 for the upper tool holder and T-slot 10H9 for the lower tool holder. Lower tools MiniBridge female straight connector (Type A) 2 pins ERNI Part- No. 172000 3 pins ERNI Part- No. 172001 4 pins ERNI Part- No. 172002 6 pins ERNI Part- No. 172003 8 pins ERNI Part- No. 172004 10 pins ERNI Part- No. 172005 12 pins ERNI Part- No. 172006 Example Lower tools MiniBridge female right angle connector (Type P) 2 pins ERNI Part- No. 172007 3 pins ERNI Part- No. 172008 4 pins ERNI Part- No. 172009 Version 5 IMS Verarbeitungsspezifikationen Seite 6 von 11

6 pins ERNI Part- No. 172010 8 pins ERNI Part- No. 172011 10 pins ERNI Part- No. 172012 12 pins ERNI Part- No. 172013 Example Assembly Position of wire Right angle cable termination (Type P) In the end position (cable beginning or cable end) of the connector, the cable tail must be aligned with the housing and cable guide respectively. Version 5 IMS Verarbeitungsspezifikationen Seite 7 von 11

The maximum permissible gap of 0.3 mm relates to the distance between the conductor and stranded wires respectively and the housing and cable guide respectively. The cable protrusion is not relevant to the assembly of the connector and can be arbitrary. The maximal permissible protrusion depends on the application of the cable assembly. An application specific guideline is recommended when the IPC-A-620 criteria is no longer sufficient. Straight cable termination (Type A) A sufficient plug-in depth for flat ribbon cable or discrete wire for straight cable termination must be safely achieved. This is guaranteed when the cable is visible inside the control window. Flat ribbon cable alignment Right angle (90 ) between the IDC connector and the flat ribbon cable should be attained. Allowable deviation is ± 2 Version 5 IMS Verarbeitungsspezifikationen Seite 8 von 11

Position of the IDC Terminal The correct flat ribbon cable or discrete wire position in the IDC is achieved when the tips of the termination clamps are visible in the corresponding window of the cable guide. MiniBridge right-angled female connector (Type P) MiniBridge straight female connector (Type A) Cable guide locking Visual characteristics Both parts (housing and cable guide) must be fully engaged, however, they must not be over-pressed. Version 5 IMS Verarbeitungsspezifikationen Seite 9 von 11

Visual characteristics of the engaged connector MiniBridge straight female connector (Type A) Cable guide (1) engaged in housing (2) Safely engaged 1 2 MiniBridge right-angled female connector (Type P) Cable guide (1) engaged in housing (2) Safely engaged 1 2 Dimensions The following dimensions must be achieved for the fully engaged, fully closed connector. MiniBridge right-angled female connector (Type P) MiniBridge straight female connector (Type A) Inspection Inspection of part characteristics Cable position Version 5 IMS Verarbeitungsspezifikationen Seite 10 von 11

Flat ribbon cable alignment Position of the IDC terminations Engaging of the housing parts Dimensions of the fully closed connector Electrical inspection A suitable contact probe with a probe tip should be used for electrical inspection. This method provides a connection on the tip of the spring contact without damaging the inspection surface. A spring loaded contact probe with a diameter of 0.35 mm and a spring load of 0.6 N is recommended. Alternatively, a male connector soldered onto the PCB can be used for the electrical inspection as well. Application note Recommendation for cable-laying For cable-laying direct behind the contact end the bending radius shall not be less than triple 1) cable diameter-size. This avoids the impairment of the insulation support at the IDC area. 1) Based on bending radii for flexible cables according to DIN VDE 0298 Part 3 Version 5 IMS Verarbeitungsspezifikationen Seite 11 von 11