OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Similar documents
OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Underground Installation of Optical Fiber Cable by Pulling

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

FIBER OPTIC CABLE PULLING

Aerial Cable Installation Best Practices

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Installation of Optical Fiber

FREEDM Loose Tube Interlocking Armored Cables

Placing Fiber Optic Cable in Underground Plant

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

Triax TechInfo. Installing and pulling Fibre Optic cables

TECHNICAL SPECIFICATION

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

Cable installation guidelines

White Paper. Next Generation of Fiber Optic Loose Tube Cable. ABSTRACT INTRODUCTION. Stephen Martin, Product Line Manager, RCDD

Aerial Installation Guidelines for Fiber Optic Cable

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

Cable Installation Tips

Mining and Petrochemical Fiber Optic Cables

Selecting the correct cable type for Outside Plant Application

Cable Installation Tips

SECTION COMMUNICATIONS HORIZONTAL CABLING

SOLO ADSS Short-Span Cables, Fibers

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

SECTION COMMUNICATIONS HORIZONTAL CABLING

Public Works Division Lighting District Fiber Optic Specifications April 2009

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Underground Installation of Optic Fiber Cable Placing

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Section Communications Optical Fiber Backbone Cabling

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications

Purchase Now ANSI/ICEA S

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Gel-sealed in-line fiber optic closure

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

PREMIUM 5e F/UTP PRODUCTS

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

OPTICAL CABLE FIBER-LAN INDOOR

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

STRUCTURED CABLE SYSTEM (SCS)

FusionLink Central Tube Ribbon Preparation & handling procedure

Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved.

GenSPEED Category 5e Cables 3

Micro duct Cable with HDPE Sheath for Installation by Blowing

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

Data Sheet HFBR-4531Z/4532Z/4533Z/4535Z. Crimpless Connectors for Plastic Optical Fiber and Versatile Link. Features. Description.

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

ETSI ES V1.1.1 ( )

Microduct Fiber Optic Cable Installation procedure

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

WIRE AND CABLE FIRE TESTS

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

SPECIFICATION. Optical Fiber Cable

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

DOME OPTIC SPLICE CLOSURE

Student Services & Classroom Addition

MXE " 3 Cell MXC "

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Fiberglass - Technical Data

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

Microduct Fiber Optic Cable Installation Procedure

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

UNOLS Wire Pool Database. Presented by Rick Trask Woods Hole Oceanographic Institution

VITALink MC. 2 Hour Fire Rated Cable UL FHIT 120/ULC S139 FHIT Installation Manual

SECTION FIBER OPTIC STATION CABLES

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

TITLE: FIBER OPTIC SHOCK FIXTURES

ANSI/ICEA S STANDARD FOR OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

OmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet

e-enterable Fiber Optic Splice Closure (Re-Enterable Aerial Closure for Access Service)

Follow The Leader In Shielded Technology

High Voltage Cables kv. Handling and Operating Instructions

LD Series High Performance Loose Tube Fiberoptic Cables

TECHNICAL SPECIFICATION

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

The FiberMark1 offers an ideal solution for

Stretch DVI TM. User s Manual DVFC-100. Manual Contents

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

Transcription:

Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Conduit Installation A conduit cable installation involves placement of one or more optical cables inside a preinstalled conduit that runs between access points. Access points can be as large as a manhole vault or small as a hand hole. Conduit installation can consist of newly installed conduits or pre-existing conduits. New conduits should be installed in as straight path as possible. Existing conduits typically require maintenance prior to installing a cable. Conduits can be installed in direct buried applications, backbone distribution systems, horizontal distribution systems, or aerial applications. Aerial conduit can reduce cable cost by eliminating the need to use aerial fiber optic cables when aerial crossings are necessary. Aerial conduits also provide cable protection against rodents, projectile objects, such as rocks and gun pellets, and harsh weather conditions. They can be used to cross highways, water, wooded areas, or any location where direct buried conduit is not a viable option. Precautions Prior to Installing Cable Temperatures Installation & Operation Installation and operating temperatures for indoor and indoor/outdoor fiber optic cables are defined in standards ICEA S-83-596 Standard for Optical Fiber Premises Distribution Cable and ICEA S-104-696 Standard for Indoor-Outdoor Optical Fiber Cable, respectively. stored in a heated storage area at least twenty four hours prior to cable installation. Clearing Conduits Using a plug approximately the same diameter as the inside of the conduit, clear all burrs and obstructions in the conduit by pulling the plug through the structure. Follow with a wire brush and swab to clean and remove foreign matter from the conduit. Smooth, burr-free conduit interiors are important in preventing abrasion damage to the cable jacket during pulling. Cable Twist Fiber optic cables should never be subjected to excessive twist. Excessive twist in the cable causes bending stress in the fibers, resulting in increased attenuation. During a conduit installation, a breakaway swivel should always be used to attach the pull rope to the cable in order to prevent twisting. Please refer to the Installation General Guidelines of the Optical Cable Corporation Installation Guide. ing Lubricants Friction between the outer jacket of the cable and the conduit creates unwanted tension on the cable while pulling the cable through the conduit. Proper cable lubrication is designed to reduce the tension on the fiber optic cable. The recommended amount of lubricant is dependent on the size and length of the conduit system as well as the jacketing and conduit material in which the cable is being pulled into. The following equation can predict a satisfactory quantity of lubricant need for an average pull. Q = 0.0015 x L x D The temperatures listed in the ICEA documents are minimum temperature ranges for these cables types. Some cable types, based upon the manufacturer, may be able to be installed and operate at different temperatures. Please consult the cable manufacturer. In cold weather installations, it is recommended that fiber optic cables be Where: Q = quantity needed in gallons L = length of pull in feet D = nominal inside diameter of conduit in inches Quantity of lubricant for complex pulls, old/dirty conduits, high conduit fill ratio, several bends, increases in elevation, and high temperatures may require an increase Page 2 of 6

in lubricant up to 50% more than the prediction listed above. It is recommended that water based lubricants be used for all cable outer jackets or lubricants that match the cable jacket type. Conduit Capacity For fiber optic cables, the National Electric Code (NEC) conduit fill tables apply only when the cables have metallic members or are placed in conduits with electrical power cables. Please refer to the NEC handbook for the conduit fill tables. For non NEC applicable installations, TIA/EIA-569-B Commercial Building Standard for Telecommunications Pathways and Spaces provides guidelines on cable capacity for conduits ranging from 16 mm (1/2 trade size) to 103 mm (4 trade size). Table 9 of the standard lists the conduit sizing for horizontal cables and Tables 10 and 11 lists the conduit fill ratio for backbone cables. However, the number of cables that can be installed is limited by the maximum pulling tensions of the cables. Please refer to TIA/EIA-569-B Commercial Building Standard for Telecommunications Pathways and Spaces for more information. To calculate fill ratio for a single cable in a conduit, the following equation can be used. Where: Fill Ratio = d 2 /D 2 d = outside diameter of cable D = inside diameter of conduit section of conduit will have more than two 90-degree bends, or equivalent, between pull points. For backbone distribution systems, TIA-758- A Customer-owned Outside Plant Telecommunications Infrastructure Standard states that no section of conduit will be longer than 183 m (600 ft) between pull points. The standard also states that no section of conduit will have more that two 90-degree bends, or equivalent, between pull points. Please refer to TIA/EIA-569-B Commercial Building Standard for Telecommunications Pathways and Spaces and TIA-758-A Customer-owned Outside Plant Telecommunications Infrastructure Standard for more information. Estimating ing Tensions Depending on the route layout, it may be necessary to estimate the pulling tensions prior to installing the cable. One key parameter in tension calculations is the coefficient of friction. The friction coefficient depends on the fiber optic cable jacket material, the conduit type, and the pulling lubricant type (if used). The lubricant manufacturers should provide friction coefficients necessary for the calculations. Once the friction coefficient has been determined, the pulling tensions can be calculated by using the following simplified formulas. Straight : T out = T in + (W)(K)(L) For multiple cables, the following equation can be used. Fill Ratio = d 1 2 + d 2 2 + + d n 2 Lengths and Bends D 2 For horizontal distribution systems, TIA/EIA- 569-B Commercial Building Standard for Telecommunications Pathways and Spaces states that no section of conduit will be longer than 30 m (100 ft) between pull Horizontal Bend: T out = T in (e KΦ ) Where: T out = Tension Exiting Section T in = Tension Entering Section W = Weight of Cable(s) K = Coefficient of Friction Φ = Angle of Bend (radians) The calculations must be done in sections. Straight pulls and horizontal bends must be calculated separately. For example, if a points. The standard also states that no Page 3 of 6

route consists of twenty feet of straight conduit and then a ninety degree bend, the straight section would be calculated first using the back tension of the reel as the T in. The ninety degree bend would then be calculated using the T out of the straight section as T in for the bend section calculation. Please note that these are simplified equations. More complex equations include weight correction factors for multiple cable pulls and gravitational corrections for nonhorizontal conduit sections and bends. ing software may be required for complex tension calculations. For more information, please refer to the annex section of TIA/EIA-569-B Commercial Building Standard for Telecommunications Pathways and Spaces. Tools and Hardware Fiber optic cable can be installed in conduits either by pulling the cable by hand or by using a capstan. When using a capstan to pull the cable through the conduit, the capstan must have a diameter that must meet the minimum bending radius of the cable under installation tensile load. The capstan must also have a tension monitoring device in order to measure the installation tensile load. Installation tensile loads in excess of 2,700 Newtons (600 pounds) are not recommended. The installation tensile load ratings for Optical Cable Corporation s cables can be found on Optical Cable Corporation s web site (www.occfiber.com), catalog, or by phone at (800) 622-7711. (Continued at top right of page) Fiber optic cable pulling sheaves should also be used at both the pulling end and pay-off end of the installation in order to maintain the proper bending radius of the fiber optic cable as the cable enters and exits the hand-hole, man-hole, etc. During the installation of fiber optic cable, it is highly recommended to use a pulling grip that attaches to the fiber optic cable and a breakaway swivel that is rated at the proper pulling tension of the cable. Please refer to the Installation General Guidelines of the Optical Cable Corporation Installation Guide. Various pull lines can be used. lines with low elasticity are preferred. The pull line can be either flat or round. However, small diameter pull lines can cut certain types of conduit when under tension. Installation Cable installations in conduit from one access point to another access point may require a capstan. Figure 1-1 below represents a typical conduit installation utilizing a capstan to pull the cable at the pulling end of the route and a sheave (or wheel block that meets the minimum bending radius of the cable) at both ends of the pull. (Continued at bottom left of page) Capstan Sheave Sheave Figure 1-1 When pulling cable through conduit to multiple access points, it may be necessary to pull to an access point, figure 8 the cable at the access point, flip the figure 8 cable, Page 4 of 6

and continue on with the pull to the next access point. This is typically done when the cable cannot be installed by passing through an access point. Figures 2-1 through 2-3 detail this type of conduit installation. The cable in the illustrations is being pulled by hand. Flip Figure 8 Figure 8 By Hand Figure 2-2 Figure 2-1 Figure 2-3 In some conduit installations, a mid-point cable pull technique may be needed to install the cable. This may due to long conduit lengths, excessive bends in the conduit, or for other reasons. This technique requires pulling the cable from a mid point access location towards one end of the route, paying of the remainder of Page 5 of 6

excess cable on the reel into a figure 8, flipping the figure 8, and pulling the rest of the cable towards the other end of the route. Figures 3-1 through 3-4 detail this type of conduit installation. The cable in the illustrations is being pulled by hand. Flip Figure 8 Figure 3-3 Figure 3-1 Figure 8 By Hand Figure 3-4 Figure 3-2 Page 6 of 6