ICN4S5490C2LS35M 4 Light F54 T5 Ho Ballast No Leads

Similar documents
I0P2P59SC35I 2-59W T8 120/277V Electronic Ballast

Electronic Ballast, High Frequency; 2 Lamp(S); 60 W Lamp Wattage; Input Voltage 120/277 V; 50/60 HZ; Parallel Wiring; Can Type Small

VZT2S54 Electr DMMG Ballast

The right fit for your high-output applications

Ariadni Dimmer For 250W CFL/Led, 600W Inc/Hal, or Lutron Hi-Lume A-Series Lte Led Driver, Clamshell Packaging In White

AYCL253PBR Ariadni 250W Led 3WAY Dimmer Brown

ILT-54HO-T5C/277 F54T5 HO > 0.98 ILT-39HO-T5C/277 F39T5 HO > 0.98 ILT-24HO-T5C/277 F24T5 HO > 0.

INNOVATIVE LIGHTING TECHNOLOGY ANNOUNCES THE SMALLEST ONE AND TWO LAMP ELECTRONIC FLUORESCENT BALLLAST AVAILABLE

Sign Illuminating Ballasts

Illustrated Feature. Options

LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances

Appendix B. Ballast Cut-sheets

Pauluhn Apex. Linear, high bay LED luminaires designed for harsh & heavy industrial applications

RadioRA 2 Enhancement and Interface, 120V main repeater with MHz to MHz or MHz to MHz

34MD Series. Motor/Driver Combination. User s Guide E. Landon Drive Anaheim, CA

American National Standard for Lamp Ballasts High Frequency Fluorescent Lamp Ballasts

Philips InstantFit LED PL-C/T Lamp

2-Piece LED Emergency Back-Up and Kits

D600EI Iv 600W Inc Slide Dimmer

Commercial Lighting Program TECHNICAL SPECIFICATION GUIDE. *Manitoba Hydro is a licensee of the Trademark and Official Mark.

Catalogue Ignitors and power switches for HID

Draft Technical Requirements Version 4.3. October 20, 2017

LED MODULES READYLINE DL

Interaction of Infrared Controls And Fluorescent Lamp/Ballast Systems In Educational Facilities

Sign Illuminating Products. Plastic Sign Fluorescent Ballasts HID Sign Ballasts T5, T8, T12 Electronic Ballasts

Philips Corepro LEDtube T8

Exploratory Analysis of Operational Parameters of Controls

Wire Connector, Wire Size 18 to 12 Gauge; Yellow; Standard Package 100 Per Box; Approval Ul; Scotchlok[T] Brand

SCALE & WEIGHT DISPLAYS

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

BRIGHT BRIGHTER BRIGHTEST ONE ILLUMINATOR DESIGN THREE LIGHT SOURCES. featuring the EvenVue Reflector System

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations

1 Power Protection and Conditioning

Dimensions and Weight Size 2.79 HEIGHT X 1.6 WIDTH X 1.19 DEPTH IN, HEIGHT X WIDTH X DEPTH MM

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Cyclo Series. user manual. MartinArchitectural

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

Safety Codes Council Conference Banff C Panel Discussion

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Mapletree Audio Design

User Manual. Model 979T and 979R Digital Audio Converters

LED PL RETROFIT LAMPS PL DirectFit Series

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

HELVAR. CONTROLLABLE ELECTRONIC BALLASTS DALI & 1-10 V controllable ballasts STANDARD ELECTRONIC BALLASTS

15 Series - Dimmer

Seattle IFMA Education Symposium June The Riddles of LED Lighting. Chris Lewis, CFM

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

Woda W7 Underwater Spotlight

llen-bradley 194R-HM4-NFPA3

AVMU2-BHD+/3G Audio monitoring Unit

Tri-level Control HF Sensor

Affordable Performance.

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

RSL MusicPower Plug-In Installation Manual For Naim NAC 72 Preamp

SERIES 6VLFL2X Lensed LED Downlight Lumen Flex

Affordable Performance.

LED Driver Compact fixed output

KRF EMC Filters Installation, Operation and Maintenance Manual

Modular pulse operated latching relay 16 A

American National Standard for Electric Lamps - Fluorescent Lamps - Guide for Electrical Measures

4 Wiring Brochure Wiring and installation of specific control

QTi 2X28/54 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DIM T5 ECG dimmable 1 10 V for FL 16 mm. Areas of application.

Kramer Electronics, Ltd. USER MANUAL. Models: TR-1YC, s-video Isolation Transformer TR-2YC, s-video Dual Isolation Transformers

Furnish and Deliver New Light Emitting Diode (LED) Fluorescent Light Tubes

WLB SERIES HID Lighting for Hose Down Applications

EGM Einthoven Goldberger Module Type 701

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

NEW! Wide Area Lighting - Rough Service Fluorescent. MULTIVOLTAGE Automatically Operates at 120 to 277 VAC 50 or 60 Hz *1142 only

FAQ #1: But LEDs last forever, why do we even care about enduser replacement?

CR Series LED Downlights. Easy to Install with Unprecedented Payback THE QUALITY YOU DEMAND WITH THE SAVINGS YOU DESERVE.

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

APQ Series Type C Power Factor Correction Banks

EXLUX ECOLUX C-LUX 6480 Series

Low Noise Solid State Phono Preamplifier User's Guide and Operating Information

LED FLAT PANEL. Surprisingly simple. Significant savings. INNOVATION. SIMPLIFIED.

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

Operating Instructions Dimmer for V Incandescent Lamps

Caseta Wireless 3-Way/Single-Pole RF Dimmer For Led, Elv, MLV, or Halogen Lights In White


Evaluating and Specifying LED Lighting

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Hi-fi for music lovers...

AMPLIFIER CATALOG FEATURING OUR UNIVERSAL MOUNTING BRACKET

PHONE: (303) FAX: (970) WEBSITE:

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas

FINELITE. 10 Year LED Warranty. High Performance 4" Aperture (HP-4) - Indirect/Direct

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

Colour Explosion Proof Video Camera USER MANUAL VID-C

FLUID VIEW 12V LED TAPE LIGHT

Photometric Test Report

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

SubstiTUBE Value EM Fighter Tube Technical Datasheet

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

MAP110 AC-DC Series Data Sheet

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Emergency lighting units EM INVERTER

Ios english manual:ios english manual.qxd 07/08/ :35 Page 1

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

EA350. Generator Automatic Voltage Regulator Operation Manual

CR Series LED Downlights Easy to Install with Unprecedented Payback

Transcription:

3804 South Street 964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 CN4S5490C2LS35M 4 Light F54 T5 Ho Ballast No Leads Philips Advance Catalog Number CN4S5490C2LS35M Manufacturer Philips Advance Description Ballast, High Frequency; Programmed Start; F54T5/Ho Lamp; 4 Lamp(S); 54 W Lamp Wattage; nput Voltage 120 V; nput Current 2 Ampere; nput Power 240 W; 50/60 HZ; 0.98 Power Factor; 1 Ballast Factor; 10 Percent Maximum THD; Series/Parallel Wiring Weight per unit 1.5 (lbs/each) Product Category Linear Fluorescent Features Ballast Factor 1 nput Current 2 AMPERE nput Power 240 W nput Voltage 120 V Lamp Type F54T5/HO Lamp Wattage 54 W Maximum THD 10 PERCENT Minimum Starting Temperature -20 DEG F Number of Lamps 4 Power Factor 0.98 Starting Type PROGRAMMED Wiring SERES/PARALLEL Dimensions and Weight Size Descriptions Additional nformation Commodity Description Description Long Description Product Type 24 NCH L X 1.18 NCH W X 1 NCH H PACKAGNG TYPE MD PACK Lamps - High ntensity Discharge (Mercury Vapor/Quartz) 4 LGHT F54 T5 HO BALLAST NO LEADS BALLAST, HGH FREQUENCY; PROGRAMMED START; F54T5/HO LAMP; 4 LAMP(S); 54 W LAMP WATTAGE; NPUT VOLTAGE 120 V; NPUT CURRENT 2 AMPERE; NPUT POWER 240 W; 50/60 HZ; 0.98 POWER FACTOR; 1 BALLAST FACTOR; 10 PERCENT MAXMUM THD; SERES/PARALLEL WRNG Linear Fluorescent Ballast

3804 South Street 964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Manufacturer nformation Brand Manufacturers Part Number Model PHL ADVANCE CN4S5490C2LS35M CN Taxonomies, Classifications, and Categories Category Description ELECTRONC BALLAST Type HGH FREQUENCY Availability Manufacturer Status Packaging Carton 1 Package 12 Weight Per each 1.46 Uses, Certifications, and Standards Approval Frequency Rating Non-Stock UL, CSA 50/60 HZ

ELECTRONC FLUORESCENT BALLASTS Ballast Life Philips Advance fluorescent electronic and magnetic ballasts are designed and manufactured to engineering standards correlating to an average life expectancy of 50,000 hours of operation at maximum rated case temperature. Since Philips Advance ballasts operate below their maximum case temperature in the majority of applications, increased ballast life can be expected. As a rule of thumb, ballast life may be doubled for every 10 C reduction in ballast case operating temperature. However, there are many variables, such as input voltage, ambient temperature, etc. which affect ballast operating temperatures, and therefore ballast life. Lamp Operating Frequency Electromagnetic ballasts and the lamps connected to them operate at an input voltage frequency of 60 Hertz (Hz), 60 cycles per second which is the standard alternating voltage/current frequency provided in North America. ballasts, on the other hand, convert this 60 Hz input to operate lamps at much higher frequencies above 20 Kilohertz (khz), 20,000 cycles per second. Philips Advance ballasts operate above 20 khz, but avoid certain ranges such as 30-40 khz (infrared) and 54-62 khz (theft deterrent systems) due to interference issues. Because electronic ballasts function at high frequency, the fluorescent lighting systems that they operate can convert power to light more efficiently than systems operated by electromagnetic ballasts (See chart below). For example, lamps operated on electronic ballasts can produce over 10 percent more light then if operated on electromagnetic ballasts at the same power levels. n effect, today s electronic ballasts provide additional energy savings by matching the light output from electromagnetic ballasts while operating the lamps at lower power. This is the main reason why electronic ballast systems are more efficient than magnetic ballast system. Crest Factor Lamp manufacturers use crest factor to determine ballast performance as it relates to lamp life. Lamp Current Crest Factor is a measurement of current supplied by a ballast to start and operate the lamp. t is basically the ratio of peak current to RMS (average) current. High crest factor currents may cause the lamp electrodes to wear out faster, reducing lamp life. Crest factor requirements are regulated by ANS (American National Standards nstitute) standards and specified by lamp manufacturers. For rapid start and instant start T8 lamps the ratio is 1.7 maximum, and for instant start slimline lamps, it is 1.85 maximum. Peak Peak Crest Factor = R.M.S. R.M.S. Weight and Size Advantages Since electronic components in electronic ballasts are smaller and lighter than the core-and-coil assembly in electromagnetic ballasts, electronic ballasts can weigh less than half as much as comparable electromagnetic models. Almost all Philips Advance electronic ballasts have a smaller cross-section than electromagnetic ballasts but maintain the same mounting dimensions. This means that they can fit into all new fixture designs and can be easily retrofitted into existing fluorescent lighting systems. Controllability The ability of a building s occupants to control how they light their space is becoming an increasingly important factor for organizations in determining what real estate they will lease, buy or invest in. The ability to dim the lights or easily shut them off completely is a trend fueled not just by a desire to help the environment, but also by significant economic benefits. These benefits include greater energy efficiency in terms of reduced HVAC costs as well as energy savings for lighting more comfortable and productive working environments, and compliance with ever tighter energy efficiency regulations. Philips Advance offers three families of electronic controllable ballasts ROVR, Mark 7 0-10V and Mark 10 Powerline. Compatibility With Powerline Carrier Systems A powerline carrier system (PLC) uses electronic wiring devices to send information via a high frequency signal over the 120V or 277V electrical power distribution system of a building. For example, PLC systems are used in automatic clock systems (master time systems) to synchronize all of the clocks in a building or reset the time after a power outage. They eliminate the need for maintenance personnel to reset hundreds of clocks throughout a facility. n a PLC system, a generator is used to impose a 1 to 4V high frequency signal on top of the existing voltage sine wave (60 Hz). This signal is generally in the 2500 to 9500Hz range, with some older systems operating at 19,500Hz or higher. Some electronic ballasts which are capacitive can absorb the signal from a PLC system. As a result, the signal becomes too weak to be heard by the receiver (like a timeclock) connected to the powerline. nstant Start vs. Rapid Start Sockets for Dimming When using dimming ballasts in fixtures, sockets must be of the Rapid Start type. Many fixtures with T-8 nstant Start electronic ballasts use jumpered or shunted nstant Start sockets. Controllable ballasts require two distinctly separate wires for each lamp socket. f you encounter shunted or jumpered sockets in a retrofit application, they must be removed and replaced with Rapid Start sockets. mproper socket application will damage the ballast and void the ballast warranty. Refer to ballast wiring diagram for proper installation. Fluorescent Lamp Burn-n Today, most lamp manufacturers do not require the burn-in of linear fluorescent lamps prior to dimming in order to attain rated lamp life and stable electrical measurements. However, some manufacturers compact fluorescent lamp sources do require a 100 hour burn-in prior to dimming. Consult your lamp manufacturer for their latest requirements. 1-10 Lighting s Atlas 2010-2011

ELECTRONC FLUORESCENT BALLASTS Ordering nformation How to Order Philips Lighting s has developed the industry s broadest distribution system for electronic ballasts. More than 3000 stocking distributors nationwide. For information on the distributor best able to serve your needs, please call 800-372-3331. Ballast Part Number Breakdown CF 2 S 26 H1 LD CFL Mounting/Connector Options BL = Bottom leads BLS = Bottom leads with mounting studs BS = Bottom mounting studs with single entry color coded connectors EL = End leads ELS = End leads with mounting studs LD = Length mounting feet with SmartMate dual entry color coded connectors LS = Length mounting feet with single entry color coded connectors QS = QuikStart Linear Fluorescent Mounting/Connector Options TP* = Thermal Protected 2LS = 2 Level Switching CFL Can Desription H1 = Hybrid metal / plastic case, size 1 L2 = Linear M1 = Metal case, size 1 M2 = Metal case, size 2 M3 = Metal case, size 3 M4 = Metal case, size 4 M5 = Metal case, size 5 M6 = Metal case, size 6 N = N can S1 = Square, style 1 S2 = Square, style 2 Linear Fluorescent Can Desription 90C = 90 C maximum case temperature rating A = A can D = D can G = G can HL = High light output L = L can LW = Low watt MC = Micro can RH* = Reduced harmonics S = Slimline SC = Small can Corporate Offices (800) 322-2086 Customer Support/Technical Service (800) 372-3331 (+) 1 847 390-5000 (nternational) Visit our web site at www.philips.com/advance Lamp Watts (Primary lamp) Wiring Configuration D = 2D, series M = Modified parallel** P = Parallel P = Programmed Start Parallel Q = Quad CFL, series S = Series T = Triple CFL, series TTS = Long twin tube, series TTP = Long twin tube, parallel Maximum Number of Lamps Family Name CF = Compact Fluorescent CN = Centium DA = ROVR DL = ROVR EB = AmbiStar ELB = AmbiStar EL = Standard EZ = Mark 10 Powerline C = Mark 5 LV = Low Cost 0-10V MB = AmbiStar OP = Optanium ZT = Mark 7 0-10V Plan your lighting installation carefully; consider using the services of a qualified lighting designer Consult your local electric utility regarding demand side management rebate programs. Select the Philips Advance electronic ballast which best matches the requirements of your application. The technical specifications in this catalog (located on pages 9-5 to 9-14) will be useful in obtaining bids from electrical contractors. Contact your local Philips Lighting s distributor. You will find them to be a helpful supplier of both products and information. nput Voltage G = 347V H = ntellivolt 347V to 480V 50/60 Hz = ntellivolt 120V to 277V 50/60 Hz J = ntellivolt 277V to 480V 50/60 Hz R = 120V V = 277V * Many current and all future electronic ballast part numbers will not use the RH-TP suffixes even though these ballasts will be thermally protected. ** Parallel Wiring Configuration. However, if one lamp fails, all other lamps in the circuit will extinguish. Lighting s Atlas 2010-2011 1-11

ELECTRONC FLUORESCENT BALLASTS T5HO For 54-80W Lamps No. of Lamps nput Volts F54T5/HO (54W) 1 347-480 Lamp Starting Method Ballast Family Catalog Number nput Power ANS (Watts) Ballast Factor Max. THD % HGH POWER FACTOR Line Current (Amps) CN-2S54+ Centium CN-2S54-90C+ 62 1.02 10 0.52-0.23 CN-2S54-90C-SC Optanium OP-2P54-SC 60 1.00 10 0.50-0.22 Centium HCN-2S54-90C-WL 62 1.02 10 0.18-0.13 Min. Starting Temp. ( F/ C) Dim. SOUND RATED A CN-2S54+ D Centium CN-2S54-90C+ 120-117 1.00 10 1.00-0.43 74 2 CN-2S54-90C-SC B Optanium OP-2P54-SC 117-114 1.00 10 0.98-0.41 TBD 347-480 Centium HCN-2S54-90C-WL 120-119 1.00 10 0.35-0.25 L 74 CN-4S54-90C-2LS E Centium 182-179 1.00 10 1.52-0.66 A CN-4S54-90C-2LS-G 3 Optanium OP-4P54-2LS-G 176-174 1.00 10 1.47-0.83 G TBD 347-480 Centium HCN-4S54-90C-2LS-G 188-186 1.04 10 0.54-0.39 CN-4S54-90C-2LS E Centium 240-234 1.00 10 2.00-0.86 CN-4S54-90C-2LS-G 4 Optanium OP-4P54-2LS-G 235-229 1.00 10 1.96-0.83 G TBD 347-480 Centium HCN-4S54-90C-2LS-G 239-237 1.00 10 0.69-0.50 F80T5/HO (80W) 1 Centium CN-1S80 91-89 1.00 10 0.76-0.33 0/-18 D 73 + Also available with leads (CN-2S24-WL, CN-2S54-WL, or CN-2S54-90C-WL) D B L Wiring Dia. 73 TBD 73 1.00" 8.90" 9.5" 16.70" 16.34" 1.7" Fig. B Fig. D ncludes connectors with no leads 1.70" 16.34" 16.70" 1.00" 16.34" 16.70" Fig. G Fig. L Refer to page 1-37 and 1-38 for wiring diagrams Refer to pages 9-24 to 9-28 for lead lengths and shipping data 1-40 Lighting s Atlas 2010-2011