www. ElectricalPartManuals. com l Basler Electric VOLTAGE REGULATOR FEATURES: CLASS 300 EQUIPMENT AVC63 4 FEATURES AND APPLICATIONS

Similar documents
www. ElectricalPartManuals. com l Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

CLASS 300 EQUIPMENT BE3-25A AUTO-SYNCHRONIZER (Single Phase)

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

EA350. Generator Automatic Voltage Regulator Operation Manual

EVC300i. Generator Automatic Voltage Regulator Operation Manual

EVC600i. Generator Automatic Voltage Regulator Operation Manual

BE3-GPR GENERATOR PROTECTIVE RELAY

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

RMX-44 & RMX-62 MIXING MATRIX. Installation & Operation Manual

MAP110 AC-DC Series Data Sheet

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

EG4015. Digital Generator Governor Controller User Manual

02/11/2015

AF-300 E11 Adjustable Frequency Drive

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Solid-State Digital Timer

ADVR-053. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

Datasheet - SRB301LC 24VAC/DC

Series CT7N Bimetallic Overload Relays

VAT 20 Adjustable Frequency Drive

Magnecraft Power Relays

ADVR-08. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

Modular Lube Lubrication Systems System Controls

multi-function meters

Panel-mounting thermostats, type series EM

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Process Transmitter RMA 422

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV.

Type Contact form Model

High Performance Outdoor Test Translators

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Standard RS232 RS ma

Generator protection relay

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

Absolute Rotary Encoder E6CP

Ordering details. Approval. Classification

GP-500 SERIES - Low Voltage

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Flat-Bed Module Recorders

Specifications. Reference Documentation. Performance Conditions

TOSHIBA Industrial Magnetron E3328

Bulletin 190 IEC Modular Starter System

Multifunction Digital Timer

Catalogue Ignitors and power switches for HID

Model Number Structure

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

Process transmitter RMA422

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

XT-17M-B relay - Delay-off, 1 C/O, 16 A

MATE3 Owner s Manual Addendum

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

clipping; yellow LED lights when limiting action occurs. Input Section Features

Type: DILM12 10(24VDC) Article No.:

Modular DAA with 2/4 Wire Convertor. XE0002D Block Diagram

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Kuhnke Technical Data. Contact Details

ALLEN BRADLEY TIMING RELAY

Luminaire installation box Surface-mounted box Ceiling installation box

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

Instruction Manual Model # Block Upconverter

KRF EMC Filters Installation, Operation and Maintenance Manual

1900/25 Vibration Monitor

AS09..S 3-pole Contactors - Spring Terminals

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

Technical data. General specifications. Indicators/operating means

Level Measurement silometer FMC 420, FMC 423

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

Figure 1: Device components

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Datasheet - SRB-E-201ST

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Programmable Power Supplies 188 W 384 W R&S HMP Series

Junior Max (JR Max ) Controller

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

COHERENCE ONE PREAMPLIFIER

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Transcription:

Using enhanced technology, the AVC63-4 voltage regulator is designed for use on 50/60 Hz brushless generators. This encapsulated regulator is economical, small in size, ruggedly constructed, and incorporates solid state technology with frequency compensation, automatic voltage buildup, overexcitation shutdown, and EM filtering as standard. FEATURES: ntegrated circuitry for compact size, simplicity, high reliability. Extremely rugged. Exciter field current 4A continuous, 7 A forcing. Regulation accuracy better than ± 1.0% no load to full load. Fast response. Frequency compensation. Overexcitation shutdown. EM suppression. Available from stock. CSA approved, File #LR 23131. l Basler Electric CLASS 300 EQUPMENT AVC63 4 VOLTAGE REGULATOR P. 0. BOX 269 HGHLAND, LLNOS 62249, U.S.A. PHONE 618-654-2341 FAX 618-654-2351 FEATURES AND APPLCATONS this page DESCRPTON AND SPECFCATONS page 2 & 3 NTERCONNECT page 3 DMENSONS page 4 NSTRUCTON MANUAL Reference Publication Number 91668 00 998 SVC-1 2-95

:::J DESCRPTON: The AVC63-4 model of voltage regulator maintains generator line voltage on brush less generators from 5 KW to over 100 KW in size. The voltage regulator senses generator average voltage to maintain a precise regulation band within ± 1 percent. This is accomplished by converting a 240 V AC single phase power input to a controlled DC signal to the generator's exciter field. The solid-state voltage build-up circuit will enable automatic generator line voltage build-up with a voltage input to the regulator of at least 6 V AC. Customer accessible stability, underfrequency and range adjusts enable fine tuning of the voltage regulator to the generator in use. <( z 0 z u.. 100 80 0 60 => a.. => 0 a: 0!cc a: w z w CD SPECFCATONS: 40 20 "CORNER FREQUENCY" --T _-[ -T.-- - The over-excitation feature assists in protecting the voltage regulator during an over-excitation fault condition. During this mode, a shutdown signal is sent to the power stage, turning the regulator off. This feature will reset when the voltage input is removed (less than 6 VAC for a minimum of 2 seconds) to the regulator. Figure 1 demonstrates the underfrequency characteristics of the voltage regulator during prime mover low speed conditions. Customer curve selection matches the voltage regulator to 50 or 60 Hz systems. --n. - J- --+- - - =r- 0 ---- 0 10 20 30 40 50 60 70 80 FGURE 1 - DC OUTPUT FREQUENCY (Hz) FREQUENCY COMPENSATON CHARACTERSTC MAX FORCNG MAX. 1 MN MN. CONT. (240 Vac NPUT) OHMS@ AMP VOLT AMP VOLT EXCTER FELD RESSTANCE 25 C MAX. OHMS SENSNG/POWER SNGLE PHASE VOLTAGE RANGE NPUT BURDEN 4 63 7 100 15 100 171-264Vac 500VA 2

SPECFCATONS (continued): DC OUTPUT POWER: 4 Adc at 63 Vdc maximum continuous, 7 Adc at 100 Vdc one minute forcing. (Forcing with 240 Vac nominal input). EXCTER FELD DC RESSTANCE: 15 ohms minimum; 100 ohms maximum. AC SENSNG/POWER NPUT: Operating range: 190-240 Vac single phase, 50/60 Hz ±10%. Burden 500VA. VOLTAGE ADJUST RANGE: 171-264 Vac. REGULATON ACCURACY: Better than ±1.0% no load to full load. RESPONSE TME: Less than 1.5 cycles for ±5% change in sensing voltage. EM SUPPRESSON: nternal electromagnetic interference filtering. OVEREXCTATON SHUTDOWN: Field voltage shuts down after time delay if exciter field voltage exceeds 1 00 Vdc ±5%. The time delay is inversely proportional to the magnitude of the detected overvoltage condition up to F+ F- 3 4 _,_.----A AVC63-4 Hz Hz the 135 Vdc point, thus allowing nominal forcing for approximately 1 minute. Beyond 135 Vdc, the field voltage is removed within 2.0 seconds. VOLTAGE BULDUP: nternal provisions for automatic voltage buildup from generator residual voltages as low as 6 Vac. TERMNATONS: 1/4" "Fast-On" Terminals. POWER DSSPATON: 15 Watts maximum. OPERATNG TEMPERATURE: -40 C (-13 F) to +60 C (+140 F). STORAGE TEMPERATURE: -40 C (-40 F) to +85 C (+ 185 F). VBRATON: Withstands 1.2 Gs at 5 to 26 Hz; 0.036" double amplitude at 27 to 52 Hz; and 5 Gs at 53 to 500 Hz. SHOCK: Withstands up to 15 Gs in each of three mutually perpendicular axes. WEGHT: 8 oz. (0.22 kg) Net. NOTES:.&. FOR 50HZ OPERATON, MOVE JUMPER TO 50HZ TERMNAL. &. FOR REMOTE VOLTAGE ADJUST, USE 1000 OHMS, 1/2 WATT (MN) POT FOR 10% ADJUSTMENT RANGE. ffi USE FAST-BLOW FUSE WTH HGH CURRENT NTERRUPT CAPABLTY. OR 7t-----' nterconnection Diagram, 208/240Vac Nominal. FGURE 2 - TYPCAL NTERCONNECTON DAGRAM 3

4.187 DA. (2 PL) NOTES:.350 (9) VOLTAGE ADJUST 0 STABLTY ADJUST t ===== _l 3.935MAX (100) ---- ------------ -- 2.660 MAX (68) Analog Voltage Controller Model AVC63 4 PN: 91668 00 126 nput 190 240 Vac, 50/60Hz, 500 VA Output 63 Vdc, 4 A U r;::;) Basler Electric @ 9 Highland, llinois USA ---..J 1) DMENSONS ARE N NCHES (MLLMETERS). 2) TERMNALS ARE QUCK-CONNECT TABS.250" x.032". (6.35 x 0.8mm) ON.400" (10.16mm) CENTERS (except 60Hz). ffi DMENSONS TO TERMNALS ARE APPROXMATE. 4) NET WEGHT= 8 OZ (0.22 KG) 5) RECOMMENDED TORQUE LMT ON MOUNTNG HARDWARE: a. #8 screw 8-10 ln-lbs b. M4 screw.9 N-m 6) USE OF LOCKNG NUT WTH NYLON NSERT RECOMMENDED WHEN NSTALLNG AVC WTH LOOSE HARDWARE. UNDERFREQUENCY ADJUST 2.200 MAX (56).181 (TYP.) (5).169 (TYP.) (4) ROUTE 143, BOX 269, HGHLAND, LLNOS U.S.A. 62249 P.A.E. Les Pins, 67319 Wasselonne Cedex FRANCE PHONE 618-654-2341 FAX 618-654-2351 PHONE (33-3-88) 87-1010 FAX (33-3-88) 87-0808 http://www.basler.com, info@basler.com Printed in U.S.A.

Using enhanced technology, the AVC11 0-6 full wave voltage regulator is designed for use on 50/60 Hz brushless generators. This encapsulated regulator is small in size, ruggedly constructed, and incorporates solid state technology with frequency compensation, a build-up circuit, overexcitation shutdown, droop input, accessory input, and EM filtering as standard. FEATURES ntegrated circuitry for compact size, simplicity, high reliability. Extremely rugged. Exciter field current 6A continuous, 1 OA forcing. Regulation accuracy better than ±0.5% no load to full load. Fast response. Frequency compensation. Overexcitation shutdown. EM suppression. Accessory input. ADDTONAL NFORMATON NSTRUCTON MANUAL Request Publication 9317700101 l Basler Electric 1 0 1 AVC110-6 VOLTAGE REGULATOR c N EXCTATON ON/OFF SWTCH (F USED) Figure 1 -Typical nterconnection Diagram 277/480V nominal, 3-phase, 4-wire wye connection P. 0. BOX 269 HGHLAND, LLNOS 62249, U.S.A. PHONE 618-654-2341 FAX 618-654-2351 SVE-1 9-01

AVC11Q-6 SPECFCATONS EXCTER SENSNG DC OUTPUT F ELD RESSTANCE POWER NPUT NPUT MAX FORCNG SNGLE MAX. 10 SEC MN. MAX PHASE VOLTAGE CONT. (240Vac NPUT) OHMS@ OHMS VOLTAGE BURDEN ADJUST AMP VOLT AMP VOLT 25oC 6 110 10 200 DC OUTPUT POWER: 6 Adc at 110 Vdc maximum continuous, 10 Adc at 200 Vdc 10 seconds forcing. (Forcing with 240 Vac nominal input). EXCTER FELD DC RESSTANCE: 18.3 ohms minimum; 100 ohms maximum. AC POWER NPUT: Operating range: 180-277 Vac single phase, 50/60 Hz or 125Hz PMG ±10%. Burden 800VA. SENSNG NPUT: 342-528 Vac single phase, 50/60 Hz ±10% <5VA. VOLTAGE ADJUST RANGE: 342-528 Vac. REGULATON ACCURACY: Better than ±0.5% no load to full load. RESPONSE TME: Less than 1.5 cycles for ±5% change in sensing voltage. EM SUPPRESSON: nternal electromagnetic interference filtering. PARALLEL COMPENSATON: SA <10VA. Adjustable up to 6% droop for 0.8PF. ACCESSORY NPUT: ±3Vdc signal causes a ±30% change in the regulation set point. OVEREXCTATON SHUTDOWN: Field voltage shuts down after time delay if exciter field voltage exceeds a set point adjustable approx. 75-125Vdc. The time delay is inversely proportional to the magnitude of the detected overvoltage condition up to the 240 Vdc point, thus allowing nominal forcing for approximately 10 seconds. Beyond 240 Vdc, the field voltage is removed instantaneously. 18.3 100 RANGE 180-277Vac ±10% 50/60Hz 125Hz PMG 800VA RANGE 342-528Vac 50/60Hz VOLTAGE BULDUP: nternal provisions for automatic voltage buildup from generator residual voltages as low as 5 Vac. TERMNATONS: Screw type. POWER DSSPATON: 35 Watts maximum. OPERATNG TEMPERATURE: -40 C (-40 F) to +60 C (+ 140 F). STORAGE TEMPERATURE: -40 C ( -40 F) to + 70 C ( + 158 F). VBRATON: Withstands 1.5 Gs at 5 to 29 Hz; 0.036" double amplitude at 29 to 52 Hz; and 5 Gs at 52 to 500 Hz. SHOCK: Withstands up to15 Gs in each of three mutually perpendicular axes. WEGHT: 12.58 oz. (0.38 kg) Net. 4.912 (1248) ----1 49 2 - -- 1----4.528 ---- 1( ( 12.5) 1 15.0) 1---- 5512 -- ---1 (140 0) Figure 3 - Outline Drawing (Top view) Basler Electric ROUTE 143, BOX 269, HGHLAND, LLNOS U.S.A. 62249 P.A.E. Les Pins, 67319 Wasselonne Cedex FRANCE PHONE 618-654-2341 FAX 618-654-2351 PHONE (33-3-88) 87-1010 FAX (33-3-88) 87-0808 228 DA HOLE (58) (4 PLACES) http://www. basler. com, i nfo@basler.com 02BJQ.)4 11-02-96 Printed in U.S.A.