OFI-400 Series Optical Fiber Identifiers. OFI-400 Series Models

Similar documents
OFI Optical Fiber Identifier User s Guide

User's Guide to the PROLITE-30B

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

OpticalProducts. Illuminating Your Network. Testing the World s Networks

2 GENERAL DESCRIPTION

Compact live fiber identifier with integrated optical power meter

Light Source. Specification & User Manual

Fiber Optic Meter Fiber Optic Source

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

HCS - HES Cabling Systems

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

INSTALLATION INSTRUCTIONS

L-Band Fiber Optic Link

3M Fiber Optic Wall Mount Enclosure 8430 Series

Model OTDV Broadcast Transport Links OPERATING MANUAL

CN Remove the scanner assembly (X476 and X576 models) and all doors/covers.

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

Service FOR SERVICE. Quick Reference Guide. Page 23. Contact your help desk at

DGC-1000A CLAMP-ON GROUND RESISTANCE TESTER

FTK200. Users Guide. Optical Fiber Test Kit

SatellitePlus Model OLAT/OLAR. Advanced L-Band Series. 10-4,000 MHz OPERATING MANUAL

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Buffer Tube Midspan Access Tool Accessing fibers in buffer tube procedure

U SER S G UIDE. TS2002A Fiber Optic Test Kit

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

SLiC Fiber Aerial Closure System

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

Datasheet: MultiFiber Pro Update

ST800K-U Optical Power Meter. User Manual V1.0

OPTICAL POWER METER WITH SMART DETECTOR HEAD

OTLT / OTLR 3000 Manual. L-Band Fiber Optic Link MHz INSTRUCTION MANUAL

LTS-1500 Fiber Optic Test Set Operating Instructions

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

Lensed Fibers & Tapered Ends Description:

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

3M No Polish Jacketed SC/APC Connector

Optical Distribution Box 300 Installation Guide. Version : R0.0

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

Introduction...2. Features...2 Safety Precautions...2. Installation...4

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

Crimp & Cleave Termination Instructions for SEL ST Connectors

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

PM-1500 / LS-1500 Fiber Optic Power Meter and Light Source Operating Instructions. Quality Fiber Optic Test Equipment

3M Distribution Box (DDB)

3M No Polish Jacketed SC/APC Connector

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

Analog to Digital conversion of HD video. The HD-Now provides a simple method of upgrading ROVs for live HD. Keep existing infrastructure intact.

Fiber ICT. Optical Fiber Catalogue

VOH681/VOH681P. ion Manual

FTE6100 Tunable Laser Source User's Guide

SimpliFiber Pro. Users Manual. Optical Power Meter and Fiber Test Kits

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

Passive Four Channel Stereo/Mono Mixer/Splitter. Artcessories. User's Manual

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

Model 4700 Photodiode Characterizer

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

Extreme Density Networks Are You Ready?

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

Operating Instructions DCI-50-CT Cable Identifier

PSM-003. Micro Polarization Controller/Scrambler. User Guide

Operating Instructions DCI-50-CT Cable Identifier

Fiber Meter. Specification & User Manual

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

Fiber tester. Optical power meter XL-FM141. Optical power meter User s Manual

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

Gel-sealed in-line fiber optic closure

Advanced Test Equipment Rentals ATEC (2832)

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

J R Sky, Inc. Cross-Modulation Distortion Analyzer

Datasheet: SimpliFiber Pro

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

Datasheet: MultiFiber Pro

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

T-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

Shifty Manual. Shifty. Voice Allocator Hocketing Controller Analog Shift Register Sequential/Manual Switch. Manual Revision:

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Amplifier for fiber optics. Dimensioned drawing

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

TECHNICAL SPECIFICATION

DP1 DYNAMIC PROCESSOR MODULE OPERATING INSTRUCTIONS

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

Installation & Programming Manual. Please read before using this timer.

LDG M-7600 External Meter for Icom IC-7600

Section Communications Optical Fiber Backbone Cabling

Transcription:

OFI-400 Series Optical Fiber Identifiers Quick Reference Guide MODEL FIBER SIZE DESCRIPTION AND FUNCTION OFI-400 SM fibers: 250 µm coated 900 µm coated Ribbon 2 mm jacketed 3 mm jacketed Designed for use with a wide range of single-mode fibers. Ideal for network personnel involved in installation, reconfiguration, restoration, and maintenance tasks that involve bare, buffered, jacketed, or ribbon fibers in outside plant pedestals, fiber cabinets, aerial enclosures, and inside plant premises demarcation cabinets. Facilitates access in crowded splice trays. OFI-400C SM fibers: 2 mm jacketed 3 mm jacketed OFI-400HP SM fibers: 2 mm jacketed 3 mm jacketed OFI-400 Series Models Ideal for general purpose maintenance, configuration, and installation tasks. Functionally equivalent to the OFI-400 model but includes an optical head design and a calibration scheme optimized for use with jacketed fibers. Designed for use where high levels of optical power are present. Ideal for fibers carrying a single high-power signal, CWDM or DWDM signals with high total power levels, amplified optical signals, or pump lasers associated with EDFA or Raman amplifiers. When display reaches +23 (200 mw) or greater, the OFI-400HP displays High warning indication. www.aflglobal.com or (800) 321-5298, (603) 528-7780 1

FEATURE NAME Power key db Front Panel Keys and Indicators Direction of Traffic indicators No Signal indicator db/ / Set Ref key Backlight key LCD Display KEY OR INDICATOR FUNCTION This key provides two functions as follows: Press and release the key to turn the OFI identifier On or Off (optionally pull the trigger to activate the OFI). OFI automatically turns off after four (4) minutes of inactivity. Press and hold the key during power up until the letter P is displayed to disable the Auto Off feature. Note: OFI identifier will stay powered up until the Power key is pressed to turn it Off. Left and Right arrows identify the direction of the detected Traffic signal and will illuminate accordingly when a traffic signal is present regardless of the transmission rate. Note: Traffic is a light signal modulated by a random data sequence. Illuminates to indicate absence of an optical signal. Provides two functions as follows: Press and hold the key until the word HELD is displayed to store the currently measured absolute power () level as the new reference level. Once the new reference is set, the OFI identifier switches to the relative power (db) measurement mode. Press and release the key to toggle the displayed core power measurements between and db. When the OFI identifier is turned on, press the key to toggle the Backlight feature On or Off. Shows various test and settings data Core power measurements or absence of signal When present multiple Tone frequencies High (OFI-400HP only), HI and LO warnings Low batteries status 2

REF # DESCRIPTION Display Readings 1 The Battery icon appears on the OFI display to indicate a low battery condition. The discharged 2 x 1.5 V alkaline batteries require replacement. 2 This field displays core power measurements values: absolute power in or relative power in db. If an optical signal is not present, this field displays LO. When power exceeds the OFI s measurement range, this field displays HI indication. 3 Depending on the selected measurement mode, this field will display the following: for absolute power measurements. db for relative power measurements. Note: once reference level is set, the user may press the db///set Ref key to toggle between the and db units of measure. 4 When detected, this field displays test Tone frequencies values 270 Hz, 330 Hz, 1000 Hz, or 2000 Hz. In the Set Ref mode, this field shows HELD label to indicate that new reference power level is set. During disabling the Auto Off feature procedure, this field displays P to indicate that the Auto Off feature is disabled. OFI-400HP model only: when the OFI-400HP display reaches +23 (200 mw) or greater, this field displays High warning indication. If a Tone signal is present, this field will alternate between the Tone value and the High indication. 1 2 4-88.8 8888 Hz 3 3

Safety and Precautions Safety Caution: To avoid serious eye injury, never look directly into the optical outputs of fiber optic network equipment, test equipment, patch cords, or test jumpers. Always assume that optical outputs are on. Precautions It is important that the precautions given below be followed to ensure operating efficiency and to prevent inducing excessive signal loss during testing. The OFI identifier utilizes an optical assembly, which must be kept free of dirt, grease and other contaminants. The OFI s head is designed to guide the fiber being tested to a precise position relative to the optical assembly. The user should be careful to place fibers gently and in the provided fiber groove. Forcing the fiber into the head assembly or misaligning it may induce optical losses above specifications. Important: The OFI identifier will not falsely indicate Tone. Therefore, only fibers identified as carrying a Tone signal should be cut. Caution: Displayed power levels on the OFI identifier should not be used to determine actual signal strength in the optical fiber. Note: Actual results can vary by several db depending on fiber type, coating material, jacket color, jacket hardness, and other factors. Note: Bright ambient room or outdoor light can cause the OFI to give false Traffic readings when testing dark fibers. To be sure that the fiber is carrying live traffic, shield the optical assembly area of the OFI with your hand. Bright ambient light cannot cause false No Signal readings, however, low level traffic signals in color-coated fiber may not be detected. 4

OFI-400 Model: Configuring the Proper Plunger Position It is very important to place the OFI-400 model plunger in the correct position for testing 250 µm and 900 µm coated and ribbon fibers or for testing 2 mm and 3 mm jacketed fibers. Remove the plunger cover and observe the plunger position. Make sure the plunger is oriented correctly for the type of fiber to be tested. If not, lift the plunger from the two retaining pins. Rotate the plunger such that the correct side is facing out and will be used for the fiber under test alignment. Replace the plunger and cover. Plunger cover Retaining pins Plunger Label Plunger Position for testing 250 µm, 900 µm and ribbon fibers Plunger Label - Top View Position for testing 2 mm and 3 mm jacketed fibers Plunger Label - Top View 2mm/3mm 250/900/RIB A 250/900/RIB 2mm/3mm A The 250/900/RIB side faces out for the 250 µm and 900 µm coated and ribbon fibers testing The 2mm/3mm side faces out for the 2 mm and 3 mm jacketed fibers testing 5

Testing Fibers OFI-400 model only: Prior to testing, make sure the plunger is oriented correctly for the type of fiber to be tested. OFI-400, OFI-400C, OFI-400HP models: 1. Turn on the OFI identifier by pressing the Power key -. Alternatively the OFI may be activated by pulling down the trigger. An audible tone generator will beep when the unit is energized. 2. Gently insert the fiber to be tested into the fiber groove located at the top of the OFI s head. 3. Pull down and hold the trigger to depress the fiber being tested against the optical assembly. 4. The OFI identifier will start taking measurements when the plunger has closed and the fiber is in the appropriate position. Once the trigger is completely retracted, the OFI will discriminate transmitted optical signals as follows: If the fiber under test is carrying service, the OFI s display will show power readings and indicate the direction of the transmitted signal by illuminating the corresponding Direction of Traffic indicator --> or. If the fiber under test is carrying a Tone signal, then the OFI s display will show the detected Tone frequency value and activate the beeper (continuous sound). When no signal is present, the OFI will illuminate the No Signal indicator and show the LO label on the display. If power exceeds the unit s measurement range, the OFI will display HI. OFI-400HP model only: when display reaches +23 (200 mw) or greater, the OFI-400HP will display High warning indication. Note: When the OFI-400HP reads High, do not clamp it onto fiber in one location for more than 30 seconds at a time, as the fiber may become heated. 6

Testing Fibers OFI-400 Model: Additional Information for Ribbon Fibers Testing Ribbon fiber is typically comprised of 4, 8, or 12 fibers with a 250 µm coating attached together. The OFI-400 models will test ribbon fibers, however, the user should be aware of some limitations. The OFI-400 will not isolate a specific fiber from the group in a ribbon. If the ribbon being tested is carrying a Tone signal on one fiber and service Traffic signal on any of the other fibers in the group, the OFI-400 will only identify the ribbon as carrying a Tone signal and no Traffic will be indicated. Caution! When testing ribbon fiber that is not carrying a Tone signal, the OFI-400 could possibly give false No Signal identification if two service fibers in the ribbon are carrying equal power in opposite directions. The signals will cancel one another resulting in a false reading. Due to detector positioning and to ensure accurate readings, it is recommended to flip ribbon fiber to test both sides. 7

Measuring Core Power 1. Turn on your OFI unit by pressing the Power key -. 2. Gently insert the fiber to be tested into the fiber groove A located at the top of the OFI s head. 3. Pull down and hold the trigger B to depress the fiber against the optical assembly. Proceed to step 4. -21 2000 Hz No Signal Set Ref db A B Measuring Absolute Power 4. Observe the display readings. 5. The core power measurement is displayed in. Note: The OFI-400 model is calibrated for Corning 250 µm SMF-28 fiber at 1550 nm for core power measurements. Readings will be invalid for fibers other than 250 µm bare fiber (approximately 20 to 30 db below the core power of 3 mm SMF jumper cable). Measuring Relative Power 4. Press and hold the db//set Ref key for a couple of seconds until the word HELD is displayed to store the currently measured level as the new reference level. Once the new reference is set, the OFI switches to the relative power (db) measurement mode. 5 Observe the display readings. 6. The relative power measurement is displayed in db. Note: You may press and release the db//set Ref key to toggle the displayed power measurements between db and. 8

9V 1310nm 1550nm Wave ID CW 2kHz 1kHz 330Hz 270Hz Mode Output Adjust Hz Identifying a Specific Fiber During installations, maintenance, rerouting, or restorations it is often necessary to isolate a specific fiber from a bundle without disrupting service. By simply clamping an OFI onto a fiber before making any cuts, the identifier will indicate if there is Traffic, Tone, or No Signal and display the detected Traffic signal direction. An audible tone generator will beep when the unit is energized and will produce continuous sound when a Tone signal is detected. When used in conjunction with a light source capable of generating a frequencymodulated Tone signal, an OFI identifier will isolate the fiber carrying the Tone from service fibers and dark fibers. 1. Connect an optical laser source producing a frequency-modulated Tone signal to the fiber to be tested. 2. Turn on your OFI and insert the fiber to be tested in the fiber groove. 3. Pull down and hold the clamping trigger to depress the fiber under test into the optical assembly. 4. When a Tone signal is detected, the OFI will display the detected Tone frequency value and produce a continuous sound. Fiber Under Test Fiber Groove -21 2000 No Signal -21 2000 Hz OLS2 DUAL Optical Laser Source OLS Optical Light Source transmits 2000 Hz Tone signal Set Ref db OFI-400 OFI-400 detects the transmitted Tone, displays the detected Tone value and produces a continuous sound 9

Cleaning Optical Assembly Optical assembly of the OFI s must be kept free from dirt or other contaminants to ensure operating efficiency and accurate measurements. Follow your company s approved cleaning procedures. AFL recommends using lint free FiberWipes and FPF1 or FCC2 cleaning fluid. 1. Remove the OFI s plunger cover. 2. Lift the plunger from the two retaining pins. Maintenance 3. Dampen the wipe with the FPF1 or FCC2 cleaning fluid and gently clean the exposed prism and optical windows. 4. Once completed, replace the plunger and plunger cover. When the Battery indicator appears at the top of the OFI s display, the 2 x 1.5 V alkaline batteries require replacement. To replace the discharged batteries: 1. Remove the retaining screw and slide the battery plate away from the unit. 2. Replace the discharged batteries. Battery Replacement 3. Replace the battery plate and retaining screw. Repair and Calibration All NOYES test equipment products are warranted for a period of (1) one year from the date of delivery to the end user. NOTICE! NOYES Optical Fiber Identifiers contain no user serviceable parts. Except for changing batteries, these units must be returned to NOYES or authorized agents for repair and calibration. 2011, AFL, all rights reserved. OFI4-00-1ENG Revision A, 2011-11-18 www.aflglobal.com or (800) 321-5298, (603) 528-7780 10