ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

Similar documents
ImproX (TRT) Twin Remote Terminal

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

AUTOMATIC VIDEO LOSS A/B SWITCH

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

4 Wiring Brochure Wiring and installation of specific control

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

TeamWork Kits Installation Guide

Caution. Hanging the Screen:

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

CG-1 CAMERA-GUARD INSTRUCTION BOOK IB647501

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Snail Fence InteleCell Deployment Guide

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

FOREST SHUTTLE S / L / M RECEIVER

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS FOR

Panel-mounting thermostats, type series EM

Switching Power Module

TAC1 Telephone Entry System

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

Access Control Keypad for MK-DV, JB-DV

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

Documentation on all Paxton products can be found on our web site -

TV Lift System Model CL-65 Installation Instructions

Safety Light Curtains GuardShield

Inductive sensor With analog output BI15-M30-LI-EXI

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

Art M Digital codelock module

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Optical Distribution Box 300 Installation Guide. Version : R0.0

Inductive sensor NI3-EG08K-Y1-H1341

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

ARS x4 MATRIX SWITCHER Instruction Manual

User s Manual Model WF100 Extension Cable for EXA100

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Azatrax Model Railroad Track Signal Control - Single Track

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Fibre Optic Modem ODW-622

Setting up the Setting up the Dragonfly 1 v June

What is SnoCam? SnoCam Installation Guide. SolarVu


Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Capacitive sensor BCT5-S18-UP6X2T-H1151

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Absolute Encoders Multiturn

Inductive sensor BI1.5-EG08K-Y1

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using.

SPACESCAN SERIES SS 02

SPECIAL SPECIFICATION 6686 BSIF CCTV Central Equipment

Panel-Mounted Thermostat

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

CI-218 / CI-303 / CI430

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Light Curtain Type LA

Unlocking of building entrance door shall be possible by pressing the monitor's door-opener button.

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Sensor technologies Proximity sensors Series ST4. Brochure

VGA AUDIO AUDIO MATRIX SWITCHER S MANUAL

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

NX APPLICATION NOTE Led Guided Assembly Connector Pinning with Continuity

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM

SBL /SBLG Series Wireless Clock

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

ODW-621. RS-232 Point-to-point applications

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Transcription:

SPECIFICATIONS MODEL NUMBER: XRT910-0-0-GB-XX XRT911-0-0-GB-XX XTT911-0-0-NN-XX IMPROX TRT ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL Working Environment XRT910-0-0-GB-XX... (Aluminium Extruded Cabinet) XRT911-0-0-GB-XX... (Open Frame Construction) Designed to work in an indoor (dry) environment, similar to IP40. The Terminal is not sealed against water. Designed to work in an indoor (dry) environment. The Terminal is not sealed against water. 10 V DC to 30 V DC, polarity sensitive. Input Voltage... Power Requirements Current (ma) Power (W) Input Voltage 10 V DC... 110 1.10 (max) Input Voltage 30 V DC... 40 1.20 (max) Relays Relay Output... Relay Contact Ratings... Digital Inputs Type... Protection Range... 2 Relays, each with NO, COM and NC contacts. 10 A at 28 V DC, 5 A at 220 V AC, 12 A at 120 V AC. 4 Dry-contact inputs. +50 V to -50 V continuous, +80 V to -80 V surge.

NOTE: Figure 1: End of Line (EOL) Sensing Circuit End of Line (EOL) Sensing enables the Terminal to raise an alarm when somebody tampers with the circuit (that is, cutting or shorting the wires) between Input 1 (of DOS [1] or DOS [2]) and GROUND (GND). In other words the Terminal distinguishes between tampering on the circuit, and the door being in an actual Normally Open state. By placing Resistors into the circuit between the Input 1 (of DOS [1] or DOS [2]) and GROUND (GND), the Terminal s Digital Input monitors a constant resistance through the circuit. When the circuit is tampered with, the Resistors are bypassed; the Terminal detects the resistance change raising an alarm. LED Diagnostic Indicators Status LED Power On... Upgrade Mode... RS485 Communications Failure... Incoming RS485 Data... Outgoing RS485 Data... Digital Inputs (1-4)... Relays (1 and 2)... Continuous Red. Flashing Red (Steady). Flashing Red (Intermittent). Flashing Green LED. Flashing Red LED. Continuous Green on detected contact closure. Continuous Red on activation of the Relay. Blank Space XRT300-0-0-GB-04 March 2008 Page 2

INSTALLATION INFORMATION Accessories Find the following when unpacking the ImproX TRT Terminal: Either an ImproX (TRT) Twin Remote Terminal with an open frame construction. The construction consists of a Trivalent Passivated Mild Steel Mounting Plate and a Biaxially-oriented Polypropylene Cover Plate. Or an ImproX (TRT) Twin Remote Terminal housed in a Black, Aluminium extruded Cabinet. The Cabinet consists of a Top Cover, a Base and two End Plates. Each End Plate is attached with four Thread Cutter Screws (2.2 x 5 mm). CAUTION: DO NOT use the Metal-oxide Varistors (25 Vrms, 500 A, 77 V max clamping) with mains power applications. Two Metal-Oxide Varistors, 25 Vrms, 500 A, 77 V max clamping. Four Brass Wood Screws (3.5 mm x 25 mm). Four Wall Plugs (7 mm). An extra Fixed Address Label. You will find the following when unpacking the Security Accessory Pack (XTT911-0-0-NN-XX): General Two TORX Fasteners (M3.5 x 10 mm). A T10 TORX Key. Remember the following when installing the ImproX TRT Terminal: NOTE: Where we specify a Remote Reader in this Manual, we imply that the same details apply to the Multi-mode Remotes. Communications Distance The RS485 communications distance between the ImproX Controller and the LAST ImproX TRT in a cable run, MUST NOT exceed 1 km (1 090 yd). Achieve this by using good quality screened, twisted 2-pair cable, with the screen EARTHED at one end. Distance between the ImproX TRT and its Remote Readers The maximum cable distance between the ImproX TRT and its Remote Readers MUST NOT exceed 10 m (33 ft). Achieve this by using good quality screened, twisted pair cable. Distance between ImproX Units You can mount ImproX TRT s directly next to each other. To avoid mutual interference, install the ImproX Remotes alongside each other at least 500 mm (20 in) apart. Jumper Links Long transmission lines or multiple star connections, may cause communication problems. Placing a Jumper Link across the jumper [TR1] in the LAST UNIT AT THE END OF THE CABLE RUN should solve the problem. XRT300-0-0-GB-04 March 2008 Page 3

EARTH Connection Connect the ImproX TRT Terminal to a good EARTH point. Using the RS485 Port, connect the EARTH Lead to the Terminal. Mains EARTH can be used, but electrical noise may exist. CAUTION: Arc Suppression When using the ImproX TRT with FCC approved accessories, ensure that the RS485 cable is routed through a separate grommet to the power cable. Also ensure that you use a CE approved Power Supply Unit. Snubber devices are recommended for EMF Flyback and Arc Suppression when driving an inductive load with the Relay, see Figure 2. Mounting the ImproX TRT CAUTION: NOTE: Figure 2: EMF Flyback and Arc Suppression Make certain that you mount the Terminal on a vibration-free surface. You can mount the ImproX TRT onto virtually any surface including metal. Select the mounting position of the ImproX TRT Terminal, considering accessibility, routing of wires and visibility of the LEDs. XRT910-0-0-GB-XX Secure the Base to the mounting surface, using four suitable screws and wall plugs (supplied), nuts and bolts or rivets. XRT911-0-0-GB-XX Secure the Mounting Plate to the mounting surface, using four suitable screws and wall plugs (supplied), nuts and bolts or rivets. XRT300-0-0-GB-04 March 2008 Page 4

Top Cover Release Mechanism 1. If installed, remove the two TORX Fasteners, using the T10 TORX Key (XTT911-0-0-NN-XX). 2. Remove the top two Thread Cutter Screws (2.2 x 5 mm) from each of the End Plates. 3. Insert a flat head screwdriver (maximum 7 mm) into the cut out in either of the two End Plates. Swivel the screwdriver until the Top Cover makes a click sound. 4. Insert the screwdriver in the gap (on the side of the ImproX TRT) between the Top Cover and the Base. Swivel the screwdriver again, to release the Top Cover from the Base. 5. Remove the remaining Thread Cutter Screws (2.2 x 5 mm) from each of the End Plates. Figure 3: Front End Plate Figure 4: Back End Plate Blank Space XRT300-0-0-GB-04 March 2008 Page 5

DIP-switch Settings NOTE: Once the DIP-switch settings are modified reset the ImproX TRT to acknowledge the new settings. Remote 1 Select and Remote 2 Select DIP-switch Settings Each of the Remote Ports has a 4-way DIP-switch to select the function of that Port. NOTE: If you set both Remote DIP-switches to the all off position then an Auto-ID will not return any Fixed Addresses. DIP-switch Position Connections 0 Channel unused. 1 2 3 No Remote attached, the Channel is used for Relay and Digital Inputs only. ImproX Remote (including the ImproX Multi-mode Remote). ImproX RF 4-Channel Receiver or ImproX (IR) Infrared Receiver. 4 Magstripe. 5 Barcode (code 3 of 9) with Checksum. 6 Barcode (code 3 of 9) without Checksum. 7 Wiegand 26-bit, 44-bit, 40-bit, 37-bit and Tag + PINcode or Reason Code Mode. (Sagem MA100, MA200 or MA300). 8 Wiegand open format. 9 If the ImproX RF is connected to Channel 1 of the TRT then Button 1 of the ImproX (QT) Quad Transmitter reports from Channel 1, Button 2, 3 and 4 do not report at all. If the ImproX RF is connected to Channel 2 of the TRT then Button 2 of the ImproX (QT) Quad Transmitter reports from Channel 2, Button 1, 3 and 4 do not report at all. XRT300-0-0-GB-04 March 2008 Page 6

10 11 12 DIP-switch Position Connections If the ImproX RF is connected to Channel 1 of the TRT then Button 3 of the ImproX (QT) Quad Transmitter reports from Channel 1, Button 1, 2 and 4 do not report at all. If the ImproX RF is connected to Channel 2 of the TRT then Button 4 of the ImproX (QT) Quad Transmitter reports from Channel 2, Button 1, 2 and 3 do not report at all. If the ImproX RF is connected to EITHER channel of the TRT then Button 1 of the ImproX (QT) Quad Transmitter reports only on Channel 1 and Button 2 reports only on Channel 2. If the ImproX RF is connected to EITHER channel of the TRT then Button 3 of the ImproX (QT) Quad Transmitter reports only on Channel 1 and Button 4 reports only on Channel 2. Table 1: Remote 1 Select and Remote 2 Select DIP-switch Settings Blank Space XRT300-0-0-GB-04 March 2008 Page 7

Wiegand Modes Mode Tag Only: Tag + PIN: Tag + Reason: Tag + PIN + Reason: Terminal Action Treats all codes received as tag codes. Treats the first Wiegand code received as the tag code, and the second Wiegand code received as the PIN-code. Treats the first Wiegand code received as the tag code, and the second Wiegand code received as the Reason Code. Treats the first Wiegand code received as the tag code. The second and third Wiegand codes received are treated as the PIN-code and Reason Code respectively. Table 2: Wiegand Modes Wiegand Mode Rules Enter PIN-codes or Reason Codes on the Reader within 10 seconds otherwise the Terminal discards the tag code. The System allows 10 seconds each for the entry of the PIN-code and the Reason Code in Tag + PIN + Reason Mode. If the ImproX TRT expects a PIN-code and receives a number greater than 65535, then the Terminal assumes the number to be a tag code. The Terminal discards the previously read Tag for the current one and the Terminal will still expect a PINcode. If the ImproX TRT expects a Reason Code and receives a number greater than 65535, then the Terminal assumes the number to be a tag code. The Terminal discards the previously read Tag for the current one and the Terminal will still expect a PIN-code or Reason Code, depending on the mode. If the Terminal expects a Reason code and instead receives a number in the range 100 to 65535, the Terminal assumes this is an error. The Terminal discards the entire transaction, entering a new tag code starts the process again. A Wiegand Keypad Reader connected to an ImproX TRT cannot be configured to read PAC-codes or special key codes. If using PIN codes and Reason Codes set the ImproX TRT switches for Wiegand 26-bit, 37-bit, 40-bit and 44-bit, not Wiegand open format. Blank Space XRT300-0-0-GB-04 March 2008 Page 8

Door Lock Select DIP-switch Settings DIP-switch Position Connections 0 Normal Lock. 1 Motor Lock. 2 Pulse or Repeating Lock. 3 4 Fail Safe or Fail Secure with Locked or Unlocked Status (Solenoid Lock). Normal Lock, no Lock or Unlock Sensors, only Emergency Mode support. Table 3: Door Lock Select DIP-switch Settings Blank Space XRT300-0-0-GB-04 March 2008 Page 9

ELECTRICAL CONNECTIONS Connecting the ImproX TRT Terminal Figure 5 shows a typical electrical connection diagram for the ImproX TRT Terminal. Figure 5: Typical ImproX TRT Electrical Connections XRT300-0-0-GB-04 March 2008 Page 10

Figure 6: Remote Port Data Connections for Third-party Devices XRT300-0-0-GB-04 March 2008 Page 11

Fixed Address Label Once the ImproX TRT is installed, sketch a rough site plan. Attach the loose (additional Fixed Address Label packaged with the Terminal) Fixed Address Label in the position of the Terminal on the sketched site plan. When the system installation is complete and all the units are represented on the site plan by their Fixed Address Labels, file the site plan for future reference. GUARANTEE OR WARRANTY CAUTION: We reserve the right to nullify the products guarantee or warranty where you have not properly installed the Metal-oxide Varistors. This product conforms to our Guarantee or Warranty details placed on our Web Site, to read further please go to www.impro.net. USER NOTES XRT300-0-0-GB-04 March 2008 Page 12

USER NOTES XRT300-0-0-GB-04 March 2008 Page 13

USER NOTES XRT300-0-0-GB-04 March 2008 Page 14

USER NOTES XRT300-0-0-GB-04 March 2008 Page 15

This manual is applicable to the ImproX (TRT) Twin Remote Terminal, XRT910-0-0-GB-04, XRT911-0-0-GB-02 and XTT911-0-0-NN-00. (The last two digits of the Impro stock code indicate the issue status of the product). XRT300-0-0-GB-04 Issue 05 Mar 2008 ImproX TRT\English Manuals\LATEST ISSUE \ImprXTRT-insm-en-05.docx XRT300-0-0-GB-04 March 2008 Page 16