Catalog 2000/2001. Multimedia Communikation Equipment. Satellite Components. Signal Processing. Terrestrial Antennas

Similar documents
Addresses. Headquarters. Service-Center. Hotline. Companies abroad

Kathrein is a leading international specialist for reliable, high-quality communication technologies.

TDH 700 Main and sub unit for digital headend

LEVEL METER FOR ANALOGUE AND DIGITAL SIGNALS

Digital headend system CDH TRIAX - your ultimate connection

CSE 2800 digital main unit

Universal compact SAT-processing

Grundig SAT Systems SATELLITE TV CONVERTER STC 1200 ENGLISH

Digital Compact Headends

receivers and home accessories

INSTRUCTION MANUAL SATELLITE. Version V4.0. NTi R. NTi. 13V[] 17V[] 22Kc[]> TBrst[] DiSEqC[] ü. Edition 11/2004 DILAN 2150 SAT LEVEL METER

SAT 75 SAT Reflector-Ø 0,75 0,85. 41, ,5 Half-value aperture 38,3 2,4 2,1. 1,37 Mount for mast Ø

5 Getting Started Connecting the DVB-T Receiver First Steps... 9

MS8631 RF WIDEBAND AMPLIFIER. MS RACK ADAPTER for Digi-8

S7000L. TV & Satellite Analyzer. All IN ONE. Satellite & Terrestrial. Key Features. Model Guide

MyM-3S Micro Master. Installation Guide. English. design for TV

MyM Pro 3S/6S Installation guide

WISI COMPACT HEADEND Channel Processing

GDB9 INSTRUCTION MANUAL DIGITAL TERRESTRIAL RECEIVER

Directional Antenna MHz K , SITEL Caponago Tel.02 /

RFT-806D. Twin Digital Modulator AV to QAM. User Manual

Figure 1: V 613 CI plug-in card

Dishes. TDS steel/tda alu. series TDS steel/tda alu. euroline TDS bulk pack DAP series LNB brackets. LNB units

RFT-851FTA. Twin DVB-T to PAL remodulator. User Manual

Figure 1: V 713 CI plug-in card

RiniLink R1000_SG. Covert Wireless Digital Surveillance COFDM System

Cisco D9865 Satellite Receiver

Interactive Satellite Terminal Installation / Validation Manual

SYMBOLS USED ON THE RECEIVER... 3 SAFETY INSTRUCTIONS... 4 I.GENERAL INFORMATION...

QRF5000 MDU ENCODER. Data Sheet

RFS-806. Digital Modulator AV to QAM. User Manual

Xpresionn Digital Terrestrial Receiver. User Guide

BROADBAND CATALOGUE. TV MICROREPEATERS DVB-T Gap Fillers and Digital & Analogue Microrepeaters

MANUAL ENG DT Also contains Menu opttions and data for built-in modulator Data for broadband amplifier QPSK NDS

The new standard for customer entertainment

PREMIUM HEADEND SYSTEM

TXSYSTEMS. Circuit of a TCG15 AD. Dish Specification 60CM

MANUAL ENG DT-1600 ENGLISH. Also contains Menu options and data for built-in modulator Data for broadband amplifier QPSK

USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade)

MyM Pro T2 Installation guide

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

FireTV User's Guide 1

SAT IF-IF conversion system 9 cable system 5 cable dscr system 17 cable system System accessories 5 cable system

Table of Contents. Table of Contents. Safety Warning General Information. Installing Equipment Channel List Guide Menu Guide Main Page

Digital TV Transmitter

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

SPECIFICATION. DVB-T/ DVB-C / Worldwide hybrid Switchable NIM Tuner

DIGICAST DTVANE. DMB-9020 HD Professional IRD OVERVIEW

广州七彩商贸有限公司. Guangzhou Qicai Business Trade Co.,LTD. Moile : Tell:

User s manual OLY 9X K OLY 9X OLY 9V. User s Guide. Headend cascade multiswitch OLY 9X K Cascade multiswitch OLY 9X. Cascade line amplifier OLY 9V

Headend Station KAB 5000

Johansson Catalogue EDITION 2013

DM-1CH SD DVB-T MODULATOR INSTRUCTION MANUAL

Mini Combo STB Model:Timbox-Mini

TDX Cabinet - main unit for TDX range of modules

Head-End Receiver Modulator

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

The new standard for customer entertainment

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica

Installation & Operational Manual

Digital Active Outdoor DVB-T/T2 Antenna

SPECIFICATION. DVB-T / Worldwide NIM Tuner

UNFOLD THE BASE. Quick Start Guide CONTENTS INSTALLING LCD TV ON THE WALL

HD RANGER+ Evolution? NO. Revolution!

Johansson Catalogue EDITION 2012

B-LINE HIGH QUALITY SYSTEM

Owner s Manual. Sat-Meter MSK 15. Order No.:

Cisco D9865 Satellite Receiver

Professional Headend Solutions. A-LINE series featuring MPEG Encoder, Multiplexer, Scrambler, Modulators, and IP Streamers

SPECIFICATION. Multistandard Demodulator tuner. ATSC/Legacy analog NTSC/BTSC

Front and Rear Panel Remote Control Connecting to a Television...4. Connecting to an Audio System...5

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Interactive Satellite Terminal Installation / Validation Manual

Ultra-ViewRF 8HD Director Monitor. User Operation Manual

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Operating instructions V 514 / X-QAM quad

Connectors, Cables, Level meters

DQT1000 MODEL DIGITAL TO QAM TRANSCODER WITH DIGITAL PROCESSING AND MULTIPLEXING

KDL-37EX503 The stylish, cost conscious, picture performer

ADR-1000AS Compact Modular SMATV Headend

MANUAL ENG DT-1610C. Also contains Menu options and data for built-in modulator Data for broadband amplifier QAM PAL

The essential Full High Definition experience

OPERATION Channel Manager HDD Installation... 22

INSTALLATION MANUAL. Model: HDD. ATSC/QAM Digital to Analog Demodulator

Re:source. Communication Module. SAT Version. Dominating Entertainment. Revox of Switzerland. E2.00

Horizon HD-STM. Combo Signal Analyzer TEST REPORT

User s Guide. Digital Satellite Receiver

TD Dishes. Flexible solutions - easy installation. your ultimate connection

I.General Information Preface Main Features For Your Safety General Operation of the Receiver Front Panel...

Multiple Band Outdoor Block Up- and Downconverters

TDX overview. TDX Headend. Quite simply a revolution. Triax A/S Bjørnkærvej Hornsyld Denmark. System technology. WEB-Configurator.

Introduction This application note describes the XTREME-1000E 8VSB Digital Exciter and its applications.

COMTECH TECHNOLOGY CO., LTD. MTAS-F SPECIFICATION

Xsarius Satmeter Pro. Manual

V/L V/H H/L H/H. Satellite - Input. Programmable Cascadable switch. with 32 User Bands with Terrestrial input & 1 Legacy port

STC 160 Head-End Station Quad modulators

MANUAL ENG DT-2100 ENGLISH QPSK

1. Before Getting Started Main Features Accessories 2

Before you can install your LCD TV on the wall, you must fi rst remove the base using the steps below:

Transcription:

Catalog 2000/2001 Multimedia Communikation Equipment Satellite Components Signal Processing Terrestrial Antennas Tap-offs, Distrib. Boxes, Couplers Mechanical Accessoires Antenna Outlet Sockets Amplifiers Connectors, Cable, Test Equipment Multiswitches Technical Apendix Contents from A to Z Installation Examples

Satellite Components Parabolic antennas Overview of universal receiving systems (LNB) Universal receiving systems (LNB) Complete packages (Hit SAT) Satellite receivers 7

Satellite Components Offset parabolic reflectors, 75 cm and 90 cm Ø Type perfect 75 perfect 90 Order No. light gray 913 969-001 913 944-101 slate gray 913 969-011 913 944-111 brick red 913 969-023 913 944-123 perfect line For fixed alignment to one or two satellites in the frequency range 10.7-12.75 GHz Particularly suitable for multiple satellite reception (multifocus) 6 apart Robust, aluminum reflector, wall thickness 1.6 mm Adjustment scale for elevation Click-in system rails for attaching 1 or 2 receiving systems from the CS... C range Robust, galvanized and powder coated mast mount with anti-rotation lock Cable duct in feed arm Feed arm pre-assembled, unfoldable Packing contains only 2 parts: - Reflector and - Mast mount Mast mount, back and and supporting arm pre-assembled, folded flat for straightforward, rapid installation, no separate parts Corrosion protected parts Three different colors Reflector Ø m 0.75 0.90 Frequency range GHz 10.7-12.75 10.7-12.75 Gain at 10.95 GHz dbi 37.3 38.3 Half-value aperture 2.4 2.0 Offset angle 21 21.1 Noise temp. at 30 elevation K 42 40 Quality factor db/k 21.1 22.3 Mount for mast Ø mm 40-89 40-89 Adjustment range, elevation 15-45 10-40 Wind load N 480 1) 600 1) Width / height cm 80/75 90.5/95.5 Weight incl. packing kg 8.95 11.0 Packing dimensions cm 95 x 80 x 22 95 x 90 x 24 Scope of delivery - Reflector - Supporting arm with adaptor plate for fitting one or two LNBs - Mast mount with el/az adjustment Can be combined with - All receiving systems CS... C (with click-in system mount) - Wall mounts and supports see Mechanical Accessories section 1) Wind load calculated in accordance with EN 50083 Part 1 with q = 800 N/m 2 and c = 1.2 8

Offset parabolic reflector, 85 cm Ø Type FESAT 850 C Order No. light gray 913 835-001 slate gray 913 835-011 dark brown 913 835-014 orange-brown 913 835-023 Reflector Ø m 0.85 Frequency range GHz 10.7-12.75 Gain at 11.3/12.1/12.6 GHz dbi 38.0/38.6/39.0 Half-value aperture 2 Offset angle 24.6 Noise temp. at 30 elevation K 55 Quality figure db/k 20.6 Mount for mast Ø mm 50-80 Adjust. range, elevation/azimuth 10-45 / 0-360 Wind load N 660 1) Width/height mm 860/945 Weight kg 11.0 Packing dimensions cm 94.5 x 96 x 20 Scope of delivery - Reflector - Supp. arm with system mount CAS 5585 N - Mast mount with el/az adjustment Can be combined with - All receiving systems CS... C - Double feed mount DFH 6 - Wall mounts and supports see Mechanical Accessories section For fixed alignment to one satellite in the frequency range 10.7-12.75 GHz Made of impact-resistant glass fiber reinforced plastic Feed mount for fitting receiving systems from the CS C range without click-in system mount Robust, galvanized, mast mount, with anti-rotation lock Adjustment scale for elevation Four different colors 1) Wind load calculated in accordance with EN 50083 Part 1 with q = 800 N/m 2 and c = 1.2 Double feed mount for FESAT 850 C Type DFH 6 Order No. 913 923-001 FESAT 850 C ASTRAreception Eutelsatreception Material Stainless steel Weight g 40 Packing Polythene bag H V H V Angled mounting plate for mounting a second receiving system CS C For simultaneous reception of two satellites about 6 apart, such as ASTRA 19.2 East and Eutelsat 13 East 9

Satellite Components Offset parabolic reflectors, 85 cm, 95 cm and 120 cm Ø Type FESAT 85 K FESAT 95 K FESAT 120 K Order No. light gray 913 054-001 913 978-001 913 968-001 slate gray - - 913 968-011 brick red - - 913 968-023 Offset parabolic reflectors For fixed alignment to one satellite in the frequency range 10.7-12.75 GHz Aluminum reflector Adjustment scale for elevation Robust mount Corrosion protected parts Cable duct in feed arm Feed arm pre-assembled, unfoldable Mast mount, back and supporting arm pre-assembled, folded flat for straightforward installation, no separate parts FESAT 85 K and 95 K Click-in system rail for attaching one or two receiving systems from the CS... C range 6 apart FESAT 95 K: Supplied in two boxes FESAT 120 K Click-in system rail for attaching 3 receiving systems in the CS... C range 3 and 6 apart Supplied in two boxes Reflector Ø m 0.85 0.95 1.20 Frequency range GHz 10.7-12.75 10.7-12.75 10.7-12.75 Gain at 10.95 GHz dbi 38.3 39.7 41.5 Half-value aperture 2.1 1.78 1.37 Offset angle 21.1 21 21.3 Noise temp. at 30 elevation K 40 38 36 Quality factor db/k 22.3 23.9 25.9 Mount for mast Ø mm 40-89 40-89 60-89 Adjustment range, elevation 15-40 15-40 5-45 Wind load (800 N/m 2 ) N 600 800 1270 Width/height mm 82.5/87.5 94.5/101.5 124.5/133.5 Weight kg 11 13 21 Packing dimensions Reflector cm 111 x 97 x 19 113 x 107 x 15 141 x 132 x 9 Mast mount cm - 80 x 29 x 19 100 x 28 x 35 Scope of delivery - Reflector - Supporting arm with feed mount - Mast mount with el/az adjustment Can be combined with - All receiving systems CS... C (with click-in system mount) - Wall mounts and supports see Mech. Accessories section 10

Hit SAT PROGRAM Offset parabolic reflectors Type Hit FESAT 65 Hit FESAT 75 Hit FESAT 85 Order No. light gray 965 038-001 965 039-001 965 040-001 slate gray 965 038-011 965 039-011 965 040-011 brick red 965 038-023 965 039-023 965 040-023 Reflector Ø m 0.65 0.75 0.85 Frequency range GHz 10.7-12.75 10.7-12.75 10.7-12.75 Gain at 10.95 GHz dbi min. 36 min. 37.3 min. 38.3 Half-value aperture 2.85 2.4 2.1 Offset angle 21.3 21 21.1 Noise temp. at 30 elevation K 46 42 40 Quality figure db/k 19.4 21.1 22.3 Mount for mast Ø mm 40-89 40-89 40-89 Adjustment range, elevation 15-45 15-45 15-45 Wind load (800 N/m 2 ) N 375 480 600 Width/height cm 67 x 71.5 75 x 80 85.5 x 90.5 Weight kg 6 6.5 9 Packing dimensions cm 80 x 95 x 22 80 x 95 x 22 90 x 95 x 24 Scope of delivery - Reflector with back/supporting arm with feed mount - Mast mount with el/az adjustment Can be combined with - Receiving systems Hit CS 201 / 300 / 320 / 400 / 404 - Wall mounts and supports see Mechanical Accessories section The solution for single or multiple subscriber systems with future-proof technology, the highest quality and an attractive price/performance ratio. A well thought out concept in which the products are available individually, as well as in packaged systems including receivers and multiswitches Offset parabolic reflectors For fixed alignment to one satellite in the frequency range 10.7-12.75 GHz Standard feed mount for all receiving systems in the Hit range Feed fitting 23 + 40 mm Aluminum reflector Adjustment scale for elevation Robust mount Corrosion protected parts Cable duct in feed arm Feed arm pre-assembled, unfoldable Back and mast mount pre-assembled, folded flat for straightforward installation, no separate parts Reflector consists of only 2 parts Stiftung Warentest (German consumer organisation) assessment: GUT (GOOD) (Issue 09/99) Double feed mount for FESAT 85 Type Hit DFH 852 Order No. 965 069-001 Eutelsat ASTRA Plastic feed mount with aluminum connecting piece for fitting a second receiving system from the Hit CS... range For simultaneous reception of satellites about 6 apart, e.g. ASTRA 19.2 East and Eutelsat 13 East, using the parabolic antenna Hit FESAT 85 11

Best.-Nr. 965 044-001 Best.-Nr. 965 045-001 1 2 Best.-Nr. 965 046-001 Low High V H V H Best.-Nr. 965 076-001 Satellite Components Overview universal receiving systems Universal receiving systems for digital and analog signals For offset parabolic antennas Single Twin Quatro Quatro with perfect... range, FESAT...C, FESAT...K multiswitch Type CS 312 C CS 322 C CS 348 C CS 358 C Order No. 913 946-001 913 966-001 913 948-004 913 977-001 Frequency ranges: Input: Output: 10.7-11.7 GHz 11.7-12.75 GHz 950-1950 MHz 1100-2150 MHz CS 312 C CS 322 C CS 348 C CS 358 C Oscillator frequencies 2 1 Low band: High band: 9.75 GHz 10.6 GHz H/V Low H/V High H/V Low H/V Low H/V High H/V High H V Low H V High each output H/V + Low/High For offset parabolic antennas Hit FESAT 65, Hit FESAT 75, Hit FESAT 85 and suitable for all standard feed mounts of 40 mm Ø Type Hit CS 300 Hit CS 320 Hit CS 400 Hit CS 404 Order No. 965 044-001 965 045-001 965 046-001 965 076-001 Frequency ranges: Input: Output: 10.7-11.7 GHz 11.7-12.75 GHz 950-1950 MHz 1100-2150 MHz Hit CS 320 Hit CS 400 Hit CS 404 Hit CS 300 Oscillator frequencies Low band: High band: 9.75 GHz 10.6 GHz H/V Low H/V High H/V Low H/V Low H/V High H/V High V H V H Low High each output H/V + Low/High Common features Reception for satellites digital/analog digital/analog digital/analog digital/analog e.g. ASTRA, e.g. ASTRA, e.g. ASTRA, e.g. ASTRA, Eutelsat... Eutelsat... Eutelsat... Eutelsat... Use 1 subscriber 2 subscriber in multi-subscriber 4 subscribers; can be systems in expanded to multiconjunction with subscriber system multiswitches using multiswitch CKR..., CMK, CVE with 22 khz signal Number of outputs 1 2 4 4 Switching capabilities Polarization V/H 13/18 V Band low/high 0/22 khz 12

Example applications Single Twin perfect / Hit-FESAT perfect / Hit-FESAT CS 312 C / Hit CS 300 CS 322 C / Hit CS 320 BWS 2910 F EDA 3902 F EDA 3902 F EDA 3902 F analog / digital analog / digital analog / digital Quatro Quatro Switch perfect / Hit-FESAT perfect / Hit-FESAT CS 348 C / Hit CS 400 CS 358 C / Hit CS 404 CKR 5041 analog / digital analog / digital analog / digital analog / digital EDA 3902 F EDA 3902 F EDA 3902 F EDA 3902 F EDA 3902 F EDA 3902 F EDA 3902 F EDA 3902 F analog / digital analog / digital analog / digital analog / digital 13

Satellite Components Universal receiving systems, digital and analog Type CS 312 C CS 322 C Order No. 913 946-001 913 966-001 Common features For all offset parabolic antennas of the perfect... range, FESAT...C, FESAT...K For the reception of e.g. ASTRA, Eutelsat, digital and analog Remotely fed via the coaxial cable(s) Easy and quick installation by means of click-in system rail Weather-proof housing for the receiving system including the F-connectors Downwardly compatible For mounting to FESAT parabolic reflectors, remove the click-in system mount and secure using the screws provided Meets EN 50083-1 and EN 50082-1 CS 312 C 11/12 GHz, Single 1 output, horizontal/vertical For individual antenna systems Polarization plane switching 13/18 V from the receiver Frequency range switching 0/22 khz from the receiver CS 322 C 11/12 GHz, Dual/Twin 2 outputs, horizontal/vertical For antenna systems with up to 2 subscribers Independent polarization plane switching using 13/18 V from the receiver Frequency range switching 0/22 khz from the receiver Frequency range Input low band GHz 10.7-11.7 or 10.7-11.7 or high band GHz 11.7-12.75 11.7-12.75 Output low band MHz 950-1950 or 950-1950 or high band MHz 1100-2150 1100-2150 Oscillator frequency GHz 9.75 (low band) 9.75 (low band) GHz 10.6 (high band) 10.6 (high band) Noise figure of the system db 0.8 0.8 Amplification db 50 50 Polarization linear, can be linear, outputs switched to horiz. can be switched ind. or vertical to horiz. or vertical Polarization decoupling db 25 25 Switching voltage for vertical plane V +13 (11.5-14) +13 (11.5-14) horizontal plane V +18 (16-19) +18 (16-19) Switching signal for low band khz 0 0 high band khz 22 22 Current consumption ma max. 130 max. 150 Connectors Ω F-socket, 75 F-sockets, 75 Operating temperature C 40 to +60 40 to +60 Weight g 465 485 Packing dimensions cm 18.5 x 12 x 9.5 18.5 x 12 x 9.5 CS 312 C H/V Low H/V High CS 322 C 2 1 H/V Low H/V Low H/V High H/V High 14

Type CS 348 C CS 358 C with built-in multiswitch Order No. 913 948-004 913 977-001 Frequency range Input low band GHz 10.7-11.7 and 10.7-11.7 high band GHz 11.7-12.75 11.7-12.75 Output low band MHz 950-1950 and 950-1950 high band MHz 1100-2150 1100-2150 Oscillator frequency GHz 9.75 (low band) 9.75 (low band) GHz 10.6 (high band) 10.6 (high band) Noise figure of the system db 0.8 0.8 Amplification db 50 50 Polarization linear, 4 outputs; linear, 4 outputs; 2 horiz. + low/high, can be switched 2 vert. + low/high vert./horiz. + low/high independently Polarization decoupling db 25 25 Switching voltage for vertical plane V - +13 (11.5-14.2) horizontal plane V - +18 (15.8-19) Switching signal for low band khz - 0 high band khz - 22 Remote feeding voltage V 12-19 on any - output Current consumption ma max. 230 max. 300 Connectors Ω F-sockets, 75 4 x F-sockets, 75 Operating temperature C 40 to +60 40 Weight g 660 660 Packing dimensions cm 18.5 x 12 x 9.5 18.5 x 12 x 9.5 CS 348 C H V Low H V High CS 358 C each output H/V + Low/High Common features For all offset parabolic antennas from the perfect... range, FESAT...C, FESAT...K For the reception of e.g. ASTRA, Eutelsat, digital and analog Remotely fed via the coaxial cable(s) Simple and quick installation by means of click-in system rail Weather-proof housing for the receiving system including the F-connectors Downwardly compatible For mounting to FESAT parabolic reflectors, remove the click-in system mount and secure using the screws provided Meets EN 50083-1 and EN 50082-1 CS 348 C 11/12 GHz, Quatro, 4 outputs Remote feeding with 11.5-19 V possible on each output For star distribution or floor distribution in conjunction with multiswitches (individual or in cascade) For channel processing CS 358 C 11/12 GHz, Quatro Switch, 4 outputs For antenna system with up to 4 subscribers Switching using integrated multiswitch All subscribers can receive analog and digital signals independent of each other Can be expanded to multiple subscribers systems by means of multiswitch with 22 khz switching signal 15

Best.-Nr. 965 044-001 Best.-Nr. 965 045-001 1 2 Satellite Components Hit SAT PROGRAM Universal receiving systems, digital and analog Type Hit CS 300 Hit CS 320 Order No. 965 044-001 965 045-001 For all Hit SAT parabolic antennas, Hit FESAT 65, Hit FESAT 75 and Hit FESAT 85 Suitable for all standard feed mounts of 40 mm Ø For the reception of e.g. ASTRA, Eutelsat, digital and analog Receiving systems (LNBs) in completely encapsulated die-cast aluminum housing Additional protection by means of plastic outer housing Low current consumption Meets EN 50083-1 and EN 50082-1 Hit CS 300 11/12 GHz, Single 1 output horizontal/vertical For individual antenna systems Polarization plane switching 13/18 V from the receiver Frequency range switching 0/22 khz from the receiver Hit CS 320 11/12 GHz, Dual/Twin 2 outputs horizontal/vertical For antenna systems with up to 2 subscribers Independent polarization plane switching using 13/18 V from the receiver independent frequency range switching using 0/22 khz from the receiver Frequency range Input low band GHz 10.7-11.7 10.7-11.7 high band GHz 11.7-12.75 11.7-12.75 Output low band MHz 950-1950 950-1950 high band MHz 1100-2150 1100-2150 Oscillator frequency GHz 9.75 (low band) 9.75 (high band) GHz 10.6 (high band) 10.6 (high band) Noise figure typ. db 0.9 0.9 Amplification db 50 50 Polarization linear, can be linear, outputs can be switched to horiz. switched indep. to or vertical horiz. or vertical Polarization decoupling db 25 25 Switching voltage for vertical polarization V +13 (11.5-14.2) +13 (11.5-14.2) horizontal polarization V +18 (15.8-19) +18 (15.8-19) Switching signal for low band khz 0 0 high band khz 22 22 Current consumption ma max. 150 max. 300 Connectors Ω F-socket, 75 2 x F-sockets, 75 Feed fitting mm 40 40 Operating temperature C 30 to +60 30 to +60 Weight g 380 450 Packing dimensions W x H x D cm 11 x 6.5 x 9.7 14.7 x 11.5 x 7.8 Hit CS 320 Hit CS 300 H/V Low H/V High H/V Low H/V Low H/V High H/V High 16

Best.-Nr. 965 046-001 Low High V H V H Best.-Nr. 965 076-001 Universal receiving systems, digital and analog with built-in multiswitch Type Hit CS 400 Hit CS 404 Order No. 965 046-001 965 076-001 Frequency range Input low band GHz 10.7-11.7 10.7-11.7 high band GHz 11.7-12.75 11.7-12.75 Output low band MHz 950-1950 950-1950 high band MHz 1100-2150 1100-2150 Oscillator frequency GHz 9.75 (low band) 9.75 (low band) GHz 10.6 (high band) 10.6 (high band) Noise figure typ. db 0.9 0.9 Amplification db 50 50 Polarization linear, 4 outputs; linear, 4 outputs; 2 horiz. + low/high, can be switched 2 vert. + low/high vert./horiz. + low/high independently Polarization de-coupling db 25 25 Switching voltage for vertical polarization V - +13 (11.5-14.2) horizontal polarization V - +18 (15.8-19) Switching signal for low band khz - 0 high band khz - 22 Remote feeding voltage V 12-18 on any - output Current consumption ma max. 300 max. 350 Connectors Ω F-sockets, 75 F-sockets, 75 Feed fitting mm 40 40 Operating temperature C 30 to +60 30 to +60 Weight g 470 470 Packing dimensions W x H x D cm 14.7 x 11.5 x 7.8 16.5 x 11.7 x 7.7 For all Hit SAT parabolic antennas Hit FESAT 65, Hit FESAT 75 and Hit FESAT 85 For the reception of e.g. ASTRA, Eutelsat, digital and analog Receiving system (LNB) in completely encapsulated die-cast aluminum housing Additional protection by means of plastic outer housing Meets EN 50083-1 and EN 50082-1 Hit CS 400 11/12 GHz, Quatro 4 outputs For star distribution or floor distribution in conjunction with multiswitches (individual or cascade) Remote feeding with 12 to 18 V possible on any output Multiswitch with standard feeding, easy to use For channel processing Hit CS 404 11/12 GHz, Quatro Switch 4 outputs For antenna systems with up to 4 subscribers Switching using integrated multiswitch All subscribers can receive analog and digital signals independent of each other Can be expanded to multiple subscriber systems by means of multiswitch with 22 khz switching signal Hit CS 404 Hit CS 400 V H V H Low High each output H/V + Low/High 17

Satellite Components Hit SAT PROGRAM Hit packages Type Hit Package Hit Package Hit Package Hit Package Hit Package Hit Package Hit Package 6511 6521 7521 7521 FTA 7521 A 7541 MS 7541 QS Order No. light gray 965 048-001 965 049-001 965 050-001 965 081-001 965 063-001 965 051-001 965 077-001 slate gray 965 048-011 965 049-011 965 050-011 965 081-011 965 063-011 965 051-011 965 077-011 brick red 965 048-023 965 049-023 965 050-023 965 081-023 965 063-023 965 051-023 965 077-023 Components, comprising of: Parabolic Hit FESAT 65 antennas Hit FESAT 75 Hit FESAT 85 LNBs Hit CS 201 Hit CS 300 Hit CS 320 Quatro Switch Hit CS 404 LNB + Hit CS 400 + multiswitch Hit CKR 5041 Analog and Hit CSR 601D Plus digital CSR 3100 FTA receiver CSR 401 D Outdoor installation for: 1 subscriber 2 subscribers 4 subscribers analog + digital Can be More subscribers expanded, e.g. with additional analog receivers, e.g. receiver Hit CSR 601 D plus SET TOP-Box can be connected with add. relay 18

Hit Sets Hit Package Hit Package Hit Package Hit Set Hit Set Hit Set Hit Set 8521 8521 A 8541 MS 752 752 A 852 852 A 965 052-001 965 064-001 965 053-001 965 066-001 965 065-001 965 068-001 965 067-001 965 052-011 965 064-011 965 053-011 965 066-011 965 065-011 965 068-011 965 067-011 965 052-023 965 064-023 965 053-023 965 066-023 965 065-023 965 068-023 965 067-023 This is a summary of the standard packages and sets. Other combinations are also possible. You will find further information in the Hit SAT brochure or in the price list. Hit Packages Complete satellite receiving systems in one box Comprising of: - Offset parabolic antenna in a choice of 3 sizes and 3 colors - Universal receiving systems Single, Twin or Quatro (switch) - - Multiswitch for multiple subscriber systems - Sat receiver, analog / digital For a wide variety of digital and analog programs Hit Sets Complete satellite outdoor unit in one box Comprising of: - Offset parabolic antenna in a choice of 3 sizes and 3 colors - Universal receiving systems Single, Twin or Quatro (switch) 19

Satellite Components Satellite receiver, analog Type CSR 401 D Order No. 965 071-001 Satellite receiver for analog TV and radio reception 1 input 400 pre-set programming positions 4-digit LED display Dynamic noise suppression, switchable 3 Scart sockets for TV, video recorder and decoder 4 Cinch sockets (audio L/R, video and 0/12 V) LNB polarity switching using switching voltage 14/18 V Fix LNB oscillator frequency (9.75/10.6 GHz) LNB oscillator frequency can also be selected (5.15/10.0/10.75/11.0/11.475 GHz) 22 khz switching signal DiSEqC 1.0 switching function PLL tuning for audio and video Possible to receive C/Ku band Volume can be adjusted in 32 steps Mute Video contrast can be adjusted in 8 steps Programmable sleep timer Parental lock/inhibit Test picture generator Data transfer from unit to unit RF section Input frequency MHz 900-2150 Input Ω F-socket, 75 LO frequency, fix GHz 9.75 / 10.6 LO frequency, switchable GHz 5.15 / 10.0 / 10.75 / 11.0 / 11.475 Input level range dbµv 49-79 IF bandwidth MHz 27 Frequency tuning PLL FM threshold, static 6 db C/N RF modulator Output signal CCIR PAL B/G, C 28-C 47 tunable (C 38 pre-set) Output and input Plug and socket acc. to IEC 169-2.75 Ω (terr. antenna) Video Output frequency 0 Hz-5 MHz De-emphasis CCIR Rec, 405-1 Output level V pp 1 Output Euro-Scart and Cinch socket Decoder output Output signal PAL, clamped, filtered, unclamped, unfiltered Output level V pp 1 Output Euro-Scart Audio Operating modes Mono / stereo De-emphasis 50 µs / 75 µs / J 17 switchable Audio carrier frequencies MHz 5-9 Bandwidth switchable khz 110 / 130 / 180 / 230 / 280 / 330 / 380 / 500 Output level 1 V pp at 600 Ohm Output Cinch and Euro-Scart LNB supply 14 V / 18 V, max. 300 ma Switching signal khz 22 Additional switching function DiSEqC 1.0 Supply voltage 230 V~ ±15% / 50 Hz Power consumption W 30 Operating temperature C +5 to +50 Weight kg 1.9 Dimensions mm 270 x 60 x 220 Packing dimensions mm 410 x 75 x 260 20

Satellite receiver, analog Type Hit CSR 601 D plus Order No. 965 060-002 RF section Input frequency MHz 920-2150 Input Ω F-socket, 75 LO frequency, fix GHz 9.75 / 10.0 / 10.6 Input level range dbµv 49-79 IF bandwidth MHz 27 Frequency tuning PLL FM threshold, static 6 db C/N RF modulator Output signal CCIR PAL B/G, C 30-C 45 tunable (C 38 pre-set) Output level dbµv 75 Output and input Ω Plug and socket acc. to IEC 169-2. 75 (terr. antenna) Video Output frequency 0 Hz-5 MHz De-emphasis CCIR Rec, 405-1 Output level V pp 1 Output Euro-Scart and Cinch socket Decoder output Output signal PAL, clamped, filtered, unclamped, unfiltered Output level V pp 1 Output Euro-Scart Audio Operating modes Mono / stereo De-emphasis 50 µs / 75 µs / J 17 switchable Audio carrier frequencies MHz 5-8.8 Bandwidth switchable khz 150 / 280 Output level 1 V pp at 600 Ω Output Cinch and Euro-Scart LNB supply 13 V / 18 V, max. 450 ma (short circ.-proof) Switching signal khz 22 Tone burst EUTELSAT specification Additional switching function DiSEqC 1.0 Supply voltage 230 V~ ±10% / 50 Hz Power consumption W 30 Operating temperature C +5 to +50 Weight kg 2.12 Dimensions mm 375 x 67 x 220 Satellite receiver for analog TV and radio reception 1 input 250 pre-set programming positions OSD menu selectable in German and English 3 Scart sockets for TV, video recorder and decoder Programming of channels for radio operation Cinch sockets for the connection to a HiFi system LNB polarity switching using switching voltage 14/18 V Selectable LNB oscillator frequency (9.75/10.0/10.6 GHz) LNB switching low /high band 0/22 khz DiSEqC 1.0 switching function for multiple satellite reception PLL tuning for audio and video Audio and video parameters adjustable on each programming position Program list with slide function Audio mode selectable per program Volume control via remote control Program name display Sleep timer, can be set from 30 minutes to 4 hours Parental lock/inhibit Data transfer from unit to unit Included in Hit-SAT packages Stiftung Warentest (German consumer organisation) assessment: GUT (price/performance winner GOOD) 21

Satellite Components Satellite receiver, analog Type Hit CSR 2601 TWIN Order No. 965 042-001 TWIN receiver for the simultaneous viewing and recording of different programs 2 inputs, tuner A and B selectable 2 x 250 pre-set programming positions Panda Wegener stereo compatible OSD menu selectable in German, English, French and Italian 3 Scart sockets for TV, video recorder and decoder Programming of channels for radio operation Cinch sockets for the connection to a HiFi system LNB polarity switching using switching voltage 14/18 V Selectable LNB oscillator frequency (5.15/9.75/10.0/10.6 GHz) LNB switching low/high band 0/22 khz DiSEqC 1.0 switching function for multiple satellite reception Possible to receive C/KU band PLL tuning for audio and video Volume can be adjusted in 16 steps Sleep timer, 4 settings in 28 days can be set Parental lock/inhibit Test picture generator Button for switching on and off Video magazine assessment: Preis/Leistungssieger GUT (price/performance winner GOOD) RF section Input frequency MHz 900-2150 Input Ω F-socket, 75 LO frequency, fix GHz 5.15 / 9.75 / 10.0 / 10.6 Input level range dbµv 49-79 IF bandwidth MHz 27 Frequency tuning PLL FM threshold, static 6 db C/N RF modulator Output signal CCIR PAL B/G, C 28-C 47 tunable Output level dbµv 75 Output and input Plug and socket acc. IEC 169-2.75 Ω (terr. antenna) Video Output frequency 0 Hz-5 MHz De-emphasis CCIR Rec, 405-1 Output level V pp 1 Output Euro-Scart Decoder output Output signal MAC unclamped, unfiltered without deemphasis / PAL 1 unclamped, unfiltered with de-emphasis / PAL 2, clamped, filtered Output level V pp 1 Output Euro-Scart Audio Operating modes Mono / stereo De-emphasis adaptive 50 µs / J 17 switchable Audio carrier frequencies MHz 5-8.8 Bandwidth switchable khz 150 / 280 / 400 switching Output level 1 V pp at 600 Ohm Output Euro-Scart LNB supply 13 V / 18 V, max. 450 ma Switching signal khz 22 Add. switching function DiSEqC 1.0 Supply voltage 230 V~ ±10%/50 Hz Power consumption W 16, stand by 8 Operating temperature C +5 to +50 Weight kg 2.85 Dimensions mm 375 x 67 x 220 22

Satellite receiver, analog and digital Type CSR 3500 AD Order No. 913 965-001 RF section Input frequency MHz 920-2150 Input level dbµv 44-84 IF bandwidth analog/digital MHz 27 / 36 Analog section Gain control AGC Scart outputs video and TV Video CCIR Rec. 405-1 Video bandwidth MHz 5 Video output level 1 Vpp at 75 Ω Audio carrier tuning MHz 5.0-9.0 Audio mode Mono / stereo switchable Audio bandwidth khz 150 / 280 switchable Audio output level 1 Vpp at 600 Ω Digital section Demodulation type QPSK Symbol rate MS/s 2-35 (SCPC, MCPC) Viterbi decoding 1 / 2.2 / 3.3 / 4.5 / 6.7 / 8.8 / 9 Reed Solomon decoding FEC: 204, 188, t = 8 Transport demultiplex Demultiplex acc. ISO/IEC 13818-1 Max. input stream MHz 60 serial, 7.5 parallel PID working capacity 32 PID SI filtering acc. DVB-SI spec. (ETS 300 468) Video decoder parameters Video decoding ISO/IEC 13818-2MP/ ML Picture format 4:3, 16:9, pan & scan letter box Resolution max. 720 x 576 Audio decoder parameters Audio decoding ISO/IEC 13818-3 layer 1 & 2 Operating mode Mono, dual, stereo, joint stereo Sampling frequency khz 16 / 22.05 / 24 / 32 / 44.1 / 48 Digital free to air receiver with additional analog receiver section TWIN receiver, for the simultaneous viewing and recording of different analog and digital programs 1400 programming positions 700 for digital television, 300 for digital radio and 400 for analog Sat programs State-of-the-art technology in reliable quality and equipped for the future 2 inputs, tuner A and B selectable Loop-through output for passing on the RF signal Ergonomic universal remote control for television, video recorder, digital and analog satellite receiver Automatic program search Simple operation by means of on-screen menu in either German, English, French or Italian Manual program store facility Ku / C band RS 232 interface for interactive use with PC Switching commands 13/18 V, 0/22 khz, DiSEqC 1.0 Cinch sockets for audio 3 SCART sockets for TV, video and decoder Info-guide for program information (EPG) Last station memory Signal strength meter for parabolic reflector setting Operating temperature 0 C to 40 C Weight 2.5 kg Dimensions (W x H x D) 337 x 240 x 69 mm RS 232 data interface Interface asynchronous, 9-pole sub-min D Data rate bps max. 19200 Input analog/digital F-socket / F-socket LNB remote feeding ma max. 400 Switching commands 13/18 V, 22 khz, DiSEqC 1.0 Supply voltage 190-260 V, 50 Hz Power consumption W 30 23

Satellite Components Satellite receiver, digital Type CSR 3100 FTA Order No. 913 972-001 Free to air receiver (DVB MPEG-2 programs) for the reception of open, unencrypted, digital signals 2000 programming positions (1500 TV and 500 digital radio) Mains on/off switch Clearly laid out screen menus (OSD) Automatic and manual search 2 SCART sockets for TV, video or analog receiver Cinch sockets for audio Volume control Electronic Program Guide (EPG) Teletext function for TV DiSEqC 1.0 technology Display for signal strength for easy setting CD quality audio replay Favorite channel function SCPC/MCPC channels can be received in C/Ku band Previous channel function Picture reproduction function (4:3, 16:9) Languages: German and English Parental lock LED clock RS 232 interface for the connection of a PC LNB switching 13/18 V, 0/22 khz and 0/12 V IR remote control Operating temperature +5 C to +50 C Weight 2.0 kg Dimensions (W x D x H) 320 x 220 x 60 mm Tuner SAT IF MHz 920-2150 Loop-through output MHz 920-2150 SAT/IF bandwidth MHz 8/55, automatic switching according to the symbol rate Input impedance Ω 75 Input level dbµv 42 82 Polarization switching 13/18 VDC, max 400 ma, short circuit-proof Band switching 0/22 khz and 0/12 V I/Q output asymmetr. output, controlled by AGC input Demo- Demodulation capacity QPSK dulator Symbol rate MS/s 2-45 Viterbi decoding rate 1 / 2.2 / 3.3 / 4.5 / 6.7 / 8.8 / 9 Reed Solomon decoding FEC: 204, 188, t = 8 Demulti- Demultiplex acc. ISO/IEC 13818-1 plexer Max. input stream MHz 60 (serial)/7.5 (parallel) PID working capacity 32 PID SI filtering Acc. DVB-SI spec. (ETS 300 468) Audio Audio decoding ISO/IEC 13818-3 layer I & II Operating mode Mono, dual, stereo, joint stereo Sampling frequency khz 32 / 44.1 / 48 Baseband video/audio output Video output impedance Ω 75 Video output level V pp 1 Audio output impedance Ω 600 unbalanced Audio output level V pp 3.0 with volume control Service Connector 9-pole D-socket port Protocol RS-232 asynchronous Data rate bps max. 38400 Front 4-digit LED display Channel numbers display 3 buttons Power, Down, Up IR sensor khz 38 PCMCIA slots - Outputs SAT-IF input Loop-through output Audio output RS 232 interface Supply voltage Power consumption F-socket F-socket Cinch 9-pole D-female type 230 V~, 50 Hz max. 40 W /stand by 7 W 24

Satellite receiver, digital Type CSR 3602 CI Order No. 913 970-001 Tuner SAT IF MHz 920-2150 Loop-through output MHz 920-2150 SAT IF bandwidth MHz 8 / 55, automatic switching to suit the symbol rate Input impedance Ω 75 Input level dbµv 42 82 Plane switching 13 / 18 VDC, max 400 ma, short circ. proof Band switching khz 0 / 22 I/Q output asymmetr. output, controlled by AGC input Demo- Demodulation capacity QPSK dulator Symbol rate MS/s 2-35 Viterbi decoding rate 1 / 2.2 / 3.3 / 4.5 / 6.7 / 8.8 / 9 Reed Solomon decoding FEC: 204, 188, t = 8 Demulti- Demultiplex acc. ISO / IEC 13818-1 plexer Max. input stream MHz 60 (serial) / 7.5 (parallel) PID working capacity 32 PID SI filtering acc. DVB-SI spec (ETS 300 468) Audio Audio decoding ISO/IEC 13818-3 layer I & II Operating Mode Mono, dual, stereo, joint stereo Sampling Frequency khz 32 / 44.1 / 48 Baseband video/audio output Video output impedance Ω 75 Video output level V pp 1 Audio output impedance Ω 600 unbalanced Audio output level V pp 3.0 with volume control Service Connector 9-pole D-socket port Protocol RS-232 asynchronous Data rate bps max. 38400 Front 4-digit LED display Channel numbers display 3 buttons Power, Down, Up IR sensor khz 38 PCMCIA slots 2 Digital stereo satellite receiver for the reception of DVB standard programs that are transmitted uncoded or coded (encrypted) and in the CID format. 2 CI for all standard common interface modules Dolby digital, CD quality on audio replay 2000 pre-set memory positions (1400 for TV, 600 for radio) Easy operation by means of OSD function 3 SCART sockets for TV, video and analog receiver Cinch sockets for audio RS 232 interface for the connection of a PC IR remote control universal Adjustment functions for LNC and distribution system parameters Search function DiSEqC 1.0 technology Signal strength display for easy setting Volume control Teletext function Favorite channel function SCPC/MCPC channels can be received in C/Ku band Previous channel function Picture reproduction function (4:3, 16:9) with pan & scan Electronic Program Guide (EPG) Languages: German, English, French and Italian Operating temperature +0 to +40 C Weight 2.5 kg Dimensions (W x D x H) 337x 240 x 69 mm Outputs SAT IF input Loop-through output Audio output RS 232 interface F-socket F-socket Cinch 9-pole D-female type Supply voltage 230 V~, 50 Hz Power consumption W max. 35 25

Satellite Components Satellite receiver, digital Type CSR 3402 QAM Order No. 913 975-001 Digital QAM receiver for the reception of digital program packages in private head end systems (SMATV) 2 CI for all standard common interface modules Automatic program search Clearly laid out on-screen display (OSD) Picture reproduction function (4:3, 16:9) with pan & scan 2 Scart sockets for TV and video recorder 4 Cinch sockets (0/12 V, video out, audio out L and R) Video in LD quality, audio in CD quality RS 232 interface for PC and software updating 4 digit 7-LED display Mains on/off switch Volume control in 64 steps Favorite channel setting Previous channel function EPG (Electronic Program Guide in the OSD) Languages: German and English LED clock Tuner Input frequency MHz 47-862 Input level dbµv 47 69 Tuning frequency steps khz 62.5 C/N (64 QAM-256 QAM) db 25 Noise figure db 8 Output bandpass quality db < 3 (5.5 MHz bandwidth) Phase noise dbc/hz 87 (10 khz offset) MPEG transport stream A/V decoding Modulation 16, 33, 64, 128, 256 QAM Transport stream MPEG-2 ISO/IEC 13818 Input data rate Mbit/S max. 90 Picture adjustment 4:3, 16:9 with pan vector Video resolution 720 x 576 (Pal), 720 x 480 (NTSC) Audio decoding MPEG-1 audio layer 1,2, Musicam Audio mode Stereo, dual, joint stereo, mono Sampling rate khz 32 / 44.1 / 48 Memory Flash Memory Mbytes 1 (up to 2 ) Program DRAM Mbytes 8 EEPROM kbytes 2 Audio/video and data in/out SCART 1 x TV, 1 x VCR RGB video out TV Scart 0/12 V 1 x Cinch CVBS video out 1 x Cinch, 2 x Scart ( TV, VCR, Aux) Analog audio out 2 x Cinch (L CH and R CH) Data interface Resolution 16 bit DAC Output level V rms max. 2 Volume and mute control RS 232 C, baud rate 114200, Sub-D 9 pin. PCMCIA Number of slots 2 Type DVB I, II common interface standard Supply voltage AC 90-240V, 50/60 Hz Power consumption max. 40 W, max. 7 W in stand by Dimensions W x H x D mm 320 x 60 x 240 Weight kg 2.0 Operating temperature C + 5 to +50 Technical data not finalised at the time of going to print Available 2nd quarter 2000 26

Terrestrial Antennas FM antennas Band antennas for television, VHF I and III Channel antennas for television, VHF III Band antennas for television, UHF IV and V Multi-band antennas for VHF III and UHF IV/V Channel group antennas for television, UHF IV/V Indoor antennas 27

Terrestrial Antennas Introduction Radio Antennas Stereo signals can be received using any Hirschmann FM antenna. Because, however, a higher signal level and greater freedom from reflection are needed for clear stereo reception than for mono reception, it is usually necessary to use a directional antenna. Omnidirectional reception The omnidirectional radio antenna has approximately the same sensitivity for all directions and can only be recommended for well supplied reception areas. Radiation pattern The most important terms 2 1 Side lobe Average of 1 and 2 Major lobe -3 db Angle of acceptance U r U v Gain Ratio of an antenna s receive power in its main receiving direction to receive power of a L/2 dipole at the same installation site (logarithmic measure expressed in db) Angle of acceptance Angular aperture of the major lobe between the points where the gain is lower by 3 db than its maximum value Directional reception The directional antenna receives signals from one main direction better than omnidirectional antennas, but has poorer reception of signals from other directions. A directional antenna is absolutely necessary for areas where signals are weak, or in areas where a particular weak transmitter is to be received. Major lobe Section of the radiation pattern in the direction of the maximum gain Side lobe Lateral and rearward lobe-shaped sections of the radiation pattern that have a lower gain than in the main receiving direction Front to back ratio* Ratio of the voltage Uv in the main receiving direction to an average Ur generated on the basis of the voltages of the side lobe 2 in the back direction (180 ) and of the larger side lobe 1 in the rear sector (90-270 ) (logarithmic measure expressed in db) * Corresponding to a definition by the Technical Commission of the Receiving Antennas association in ZVEI 28

FM antennas Type U4 U1 Order No. 910 664-501 910 980-501 Gain db 3 0 Horizontal angle of acceptance 360 78 Dipole length m 1.5 1.5 Wind load N 49 27 Mast Ø mm max. 60 max. 54 Weight kg 0.8 0.7 Indiv. packing dimensions cm 152 x 13.5 x 11.5 149 x 10.6 x 10.5 Frequency range 87.5-108 MHz Coaxial or symmetrical connection using a quick clamp Type FM 30 FM 50 Order No. 910 906-002 910 907-002 Gain db 5 6.5-7 Front to back ratio db 14 15 Horizontal angle of acceptance 70 66 Length m 1.16 1.76 Wind load N 58 87 Mast Ø mm max. 54 max. 54 Weight kg 0.92 1.35 Indiv. packing dimensions cm 153 x 26 x 22 151 x 29 x 24 Frequency range 87.5-108 MHz Coaxial or symmetrical connection using screw clamp Swiveling mast mount Elements pre-assembled 29

Terrestrial Antennas Antenna head for AM and FM Type GEMA 4 KR Order No. 910 802-501 Pattern Frequency range: AM 0.15-26.1 MHz, FM 87.5-108 MHz To be mounted on the tip of masts AM reception with fiberglass rod Coaxial connection Protection against surge voltages and static charges in accordance with EN 50083-1 AM reception with 1.2 m long fiberglass rod AM gain db 6 1) Directional characteristic for FM reception Crossed dipole Gain for FM db 3 Front to back ratio db - Horizontal angle of acceptance 360 Length m 1.5 (dipole) Wind load N 71 Mast Ø mm 36-54 Weight kg 2.0 Indiv. packing dimensions cm 120 x 13 x 13 1) Referred to the radio reference antenna conforming to DIN 57 855 Part 2/VDE 0855 Part 2, 4.1.1., with 2 measurement frequencies 1 MHz. Band antenna for VHF I Type FESA 2 RA/K2-4 Order No. 912 650-534 For channels 2-4 Coaxial connection using a quick clamp Swiveling mast mount Channels 2-4 Gain db 3 Front to back ratio db 9 Horizontal angle of acceptance 75 Length m 1.09 Wind load horizontal N 82 vertical N 104 Mast Ø mm max. 60 Weight kg 1.6 Indiv. packing dimensions cm 185 x 17.5 x 11.5 30

Band antennas for VHF III Type FESA 4 BV FESA 13 BV Order No. 910 890-501 910 893-501 Channels 5-12 5-12 Gain db 5.5 9-11 Front to back ratio db 14 23 Horizontal angle of acceptance 60 45 Vertical 95 60 Length m 0.53 2.51 Wind load horizontal N 32 89 vertical N 36 112 Mast Ø mm max. 54 max. 60 Mast mount fixed swiveling Weight kg 0.5 1.5 Indiv. packing dimensions cm 18 x 96 28 x 146 For channels 5-12 Suitable for horizontal or vertical installation Vertical installation possible only on support TRAG 53 (see Mechanical Accessories section) Coaxial or symmetrical connection using a quick clamp Channel antennas for VHF III, Super-Magneta 9 db gain class Type FESA 309 AN K.. Order No. 910 838-... Order No. Index -505-506 -507-508 -509-510 -511 Channel 5 6 7 8 9 10 11 Gain db 9 9 9 9 9 9 9 Front to back ratio db 23 23 23 23 23 23 23 Angle of accept. horizontal 52 52 52 52 52 52 52 vertical 66 66 66 66 66 66 66 Length m 1.53 1.48 1.44 1.39 1.35 1.29 1.23 Wind load horizontal N 32 31 30 29 29 28 27 vertical N 54 52 50 49 47 46 44 Weight kg 1.34 1.34 1.34 1.30 1.30 1.30 1.30 Indiv. packing dimensions cm 112 x 14 x 11 104 x 14 x 11 Suitable for horizontal or vertical installation 31

Terrestrial Antennas Band antennas for UHF IV/V, Super-Spectral 15dB gain class Type FESA 815 N 37 Order No. 910 862-501 Suitable for horizontal or vertical installation For channels 21-37 Channels 21-24 25-30 31-37 Gain db 12.5 13.5 15 Front to back ratio db >30 30 >30 Angle of accept. horiz. 42 37 31 vertical 50 43 34 Length m 1.45 Wind load horiz. N 89 vertical N 124 Weight kg 2.8 Indiv. packing dimensions cm 78 x 49.5 x 11 Type FESA 815 N 48 Order No. 910 863-501 For channels 21-48 Channels 21-23 24-28 29-34 35-41 42-48 Gain db 11.5 12 13 14 15 Front to back ratio db 28 30 28 >30 26 Angle of accept. horiz. 44 41 37 32 27 vertical 52 48 42 36 29 Length m 1.38 Wind load horiz. N 87 vertical N 120 Weight kg 2.7 Indiv. packing dimensions cm 70.5 x 49.5 x 11 Type FESA 815 N 69 Order No. 910 865-501 For channels 21-69 Channels 21-25 26-30 31-36 37-42 43-49 50-55 56-62 63-69 Gain db 9 9.5 10 10.5 11 12 13.5 15 Front to back ratio db 22 23 >25 >28 >28 25 24 22 Angle of accept. horiz. 50 46 42 40 38 35 31 27 vertical 60 55 50 47 43 39 35 30 Length m 1.22 Wind load horiz. N 83 vertical N 110 Weight kg 2.6 Indiv. packing dimensions cm 71.5 x 49.5 x 11 32

Band antennas for UHF IV/V, Super-Spectral 17dB gain class Type FESA 817 N 37 Order No. 910 866-501 For channels 21-37 Channels 21-23 24-26 27-30 31-37 Gain db 14.5 15 16 17 Front to back ratio db 30 >30 >30 28 Angle of accept. horiz. 33 30 28 23 vertical 37 35 32 26 Length m 2.72 Wind load horiz. N 136 vertical N 217 Weight kg 3.8 Indiv. packing dimensions cm 104.5 x 61 x 11 Suitable for horizontal or vertical installation If horizontal installation is intended, it is recommended to install the antenna at the tip of the mast or on a support (TRAG 53, see Mechanical Accessories section) Type FESA 817 N 48 Order No. 910 867-501 For channels 21-48 Channels 21-24 25-29 30-34 35-40 41-48 Gain db 13 14 15 16 17 Front to back ratio db >30 27 30 29 29 Angle of accept. horiz. 34 33 30 25 21 vertical 37 36 33 30 24 Length m 2.54 Wind load horiz. N 132 vertical N 203 Weight kg 3.8 Indiv. packing dimensions cm 99.5 x 58 x 11 Type FESA 817 N 69 Order No. 910 869-501 For channels 21-69 Channels 21-26 27-33 34-40 41-48 49-55 56-62 63-69 Gain db 10.5 12 13 14 15 16 17 Front to back ratio db 24 28 30 >30 28 27 26 Angle of accept. horizontal 43 39 35 31 27 24 21 vertical 51 45 40 35 31 28 26 Length m 2.08 Wind load horiz. N 124 vertical N 183 Weight kg 3.4 Indiv. packing dimensions cm 115 x 38.5 x 11 33

Terrestrial Antennas Band antennas for UHF IV/V Type FESA 7 BO 60 1) FESA 12 BO 60 1) Order No. 910 977-501 910 978-501 For channels 21-60 Suitable for horizontal and vertical installation Coaxial or symmetrical connection using screw clamps Channels 21-60 21-60 Gain db 5-9.5 6-12 Front to back ratio db 12-18 17-23 Angle of accept. horizontal 67-49 64-38 vertical 90-63 92-49 Length m 0.64 1.07 Wind load horizontal N 16 20 vertical N 23 36 Mast Ø mm max. 54 max. 54 Mast mount fixed fixed Weight kg 0.3 0.5 Indiv. packing dimensions cm 16 x 85 16 x 75 1) In self-service polythene bags suitable for retail Band antenna for UHF IV/V Type FESA 805 Order No. 910 486-502 Channels 21-68 Gain db 10-13 Front to back ratio db 20-23 Angle of accept. horizontal 50-37 vertical 40-28 Length m Aluminum shield 0.62 x 0.80 Wind load horizontal N 46 vertical N 46 Mast Ø mm max. 54 Mast mount fixed Weight kg 1.6 Indiv. packing dimensions cm 86 x 63 x 21 (3 pcs.) 34

Multi-band antennas for VHF III and UHF IV/V Type FESA 218 LDK FESA 215 L 665* Order No. 910 501-501 971 116-501 Reception bands VHF III UHF IV/V VHF III UHF IV/V Channels 5-12 21-60 5-12 21-65 Gain db max. 7.5 6-14 2-3 7-11 Front to back ratio db 15-20 17-28 15 20 Horizontal angle of accept. 70 53-31 70 46 Length m 1.28 0.7 Wind load N 104 42 Weight kg 2.1 Indiv. packing dimensions cm 72 x 43 x 18 Coaxial or symmetrical connection using a quick clamp For masts up to Ø 60 mm * For window or balcony installation, please also order FETRA 2 Channel group antennas for UHF IV/V Type FESA 2129 A FESA 2737 A FESA 3548 A Order No. 971 160-502 971 162-502 971 163-502 Channels 21-29 27-37 35-48 Gain db 11-12.5 11-12.5 11-12.5 Front to back ratio db 24 24 25 Angle of accept. horizontal 35 35 35 vertical 40 40 43 Length m 1.54 1.415 1.23 Wind load horizontal N 58 51 46 vertical N 51 45 40 Coaxial or symmetrical connection using the proven quick clamp Low wind load Swiveling mount for masts up to Ø 60 mm Elements pre-assembled Type FESA 4255 A FESA 5062 A Order No. 971 164-502 971 165-502 Channels 42-55 50-62 Gain db 11-12.5 11-12.5 Front to back ratio db 25 24 Angle of accept. horizontal 35 38 vertical 43 43 Length m 1.085 1.045 Wind load horizontal N 45 42 vertical N 40 36 35

Terrestrial Antennas Indoor FM antenna Type ZU 726 V SOUND Order No. 910 756-502 Frequency range 87.5-108 MHz Low space requirement due to shortened dipole High receive power by means of a high-grade matching network Brown plastic housing High-gloss nickel-plated dipole Reception band VHF II (FM) Gain db 10 1) Noise figure db 4 Operating voltage 230 V~ +6%, 10%/ 50-60 Hz Power consumption W 1.5 Mains connection m Cable approx. 1.5 m long with Euro plug 1) Antenna gain including amplification. Indoor antenna for VHF III and UHF IV/V Type ZIFA 796 LP-V Order No. 910 887-502 For channels 5-12 and 21-69 Logarithmic periodic antenna for UHF IV/V, shortened dipole for VHF III High receive power UHF antenna can be swivelled about the longitudinal axis to align to horizontally or vertically polarized stations VHF dipole can be swivelled with respect to the UHF antenna Very good directional effect to suppress reflections (ghost pictures) Brown plastic foot and support High-gloss nickel plated elements Reception bands VHF III UHF IV/V Gain db max. 17 1) max. 20 1) Noise figure db 2.5 3 Front to back ratio db - 15-22 Operating voltage 230 V ~ +6%, 10%/50-60 Hz Power consumption W 1.5 Mains connection m Cable approx. 1.5 m long with Euro plug Antenna connection cable m 1.5 connector Plug to IEC 169-2 (DIN 45 325) 1) Antenna gain including amplification. 36

Mechanical Accessories Supports, masts Wall mounts Plug-in masts and telescopic masts Passing through collars Sealing cuffs, clamps Mast base brackets Mast accessory sets Earth strap and bar Mast mounts and antenna supports 37

Mechanical Accessories Introduction Mast calculation The conditions detailed in the EN 50083-1 must be observed when mounting antennas on a mast. The sum of the moments resulting from the intrinsic moment of the mast and the bending moments caused by the mounted antennas must not exceed the maximum permitted bending moments of the mast itself. The bending moment caused by an antenna is calculated by the following formula: Wind load (N) x distance (m) = bending moment (Nm) The distance and bending moment refer to the top clamping point. Bending moments in excess of 1650 Nm require proof of structural stability. Wind load x distance = bending moment 1) 71 N x 2.1 m = 149.1 Nm 2) 83 N x 1.7 m = 141.1 Nm 3) 600 N x 0.9 m = 540.0 Nm Total bending moment of the antennas 830.2 Nm The usable bending moment of 896 Nm for the antennas to be mounted (see table Load carrying capacities of mast combinations ) is higher than 830.2 Nm. Therefore the intended configuration is permitted! 1) GEMA 4 KR 2) FESA 815 N 69 1 x STEMA 50 / 300 2.1 m 3) perfect 90 Hirschmann ü 1.7 m 0.9 m 0.9 m 38

Support for satellite antennas Type STG 60 Order No. 981 000-073 Substructure mounting plate Length m 1.2 Pipe Ø mm 60 Wall thickness mm 3.6 Weight kg 12.7 For antennas with Ø m 1.20 Stable design Pipe with large wall thickness Masts Type MAR 60/200 MAR 60/300 MAR 89/300 Order No. 981 000-055 981 000-056 981 000-057 Length m 2.0 3.0 3.0 Pipe Ø mm 60 60 89 Wall thickness mm 3.4 3.4 3.4 Weight kg 10 15 16 For antennas with Ø m 0.9 0.9 1.2/1.5/1.8 Max. perm. bending moment Nm 1650(2035) 1) 1650(2035) 1) 3848 For mounting satellite antennas to walls, roof beams, etc. Hot dip galvanized 1) Observe EN 50083-1 limitation: 1650 Nm. The value given in brackets may only be exploited if adequate stability of the building's structure has been verified by calculation. Wall mount Type MH 50 Order No. 601 140-100 For pipe Ø mm 27-60 Distance from wall mm 225 Weight kg 2.45 For attaching antenna masts to outside walls Wall mounting only with masonry bolts, do not use thermoplastic wall plugs 39

Mechanical Accessories Wall mounts Type MHR 42 MHR 60 Order No. 981 000-059 981 000-062 For attaching parabolic antennas to outside walls Hot dip galvanized Closed off with plastic plug Pipe diameter mm 42.4 60 Pipe thickness mm 2.3 3.65 Distance from wall mm 163 223 Drilling hole diameter mm 12 14 Weight kg 2 5.4 Special property for small parabolic antennas Used for perfect 75, Hit FESAT 65/75 FESAT 850 C, FESAT 85, perfect 90, Hit FESAT 75/85 Wall mounts Type MHR 61 MHR 89 Order No. 981 000-063 981 000-064 For attaching parabolic antennas to outside walls Hot dip galvanized Closed off with plastic plug Pipe diameter mm 60 89 Pipe thickness mm 3.65 3.2 Distance from wall mm 428 413 Drilling hole diameter mm 14 14 Weight kg 6.3 12.7 Special property Large distance from the wall, for 90 mounting, as a result 180 swivel range of the antenna Used for Hit FESAT 65/75, FESAT 95 K, FESAT 120 K FESAT 850 C, perfect 75/90 40

Wall mounts Type WH 34 WH 50 Order No. 965 014-101 965 016-101 Pipe diameter mm 50 50 Pipe thickness mm 3 3 Distance from wall mm 255 500 Drilling hole diameter mm 11 11 Weight kg 0.8 1.2 Used for Hit FESAT 65/75/85, Hit FESAT 65/75/85 FESAT 850 C, FESAT 85 K, FESAT 850 C, perfect 75 perfect 90 For attaching parabolic antennas to outside walls Made of aluminum High stability due to special aluminum profile Closed off with plastic plug Roof-space antenna pipes Type UDR 1 UDR 3 Order No. 981 000-018 981 000-019 Length m 1 1 Attachment method with pressed-in screw with screws or nails Pipe diameter mm 21 34 Pipe thickness mm 2 2 For mounting terrestrial antennas in the roof space 41

Mechanical Accessories Plug-in masts Type STEMA 42/200 STEMA 50/200 STEMA50/300 Order No. 811 077-102 813 775-102 813 775-103 Same outside diameter can be plugged together Economical combination possible due to staggered lengths Protected by bead against rotating Made of high-grade steel STEMA 42/ Sendzimier hot dip galvanized, STEMA 50/ hot dip galvanized Length m 2.0 2.0 3.0 Outer Ø mm 42 50 50 Wall thickness mm 2 2 2 Weight kg 3.92 4.74 7.12 Load carrying capacities of masts Total length L g m 2.00 2.00 3.00 Clamped length L e =1/6 L g L e m 0.33 0.33 0.50 Max. perm. bend. mom. M g Nm 730 1040 1040 Ant. up to 20 m above ground Usable bending moment M n Nm 673 975 896 Intrinsic moment of mast M s Nm 57 64 144 Ant. over 20 m above ground Usable bending moment M n Nm 652 952 842 Intrinsic moment of mast M s Nm 78 88 198 Mast combinations Type 2 x STEMA 42/200 2 x STEMA 50/200 Load carrying capacities of masts Total length L g m 3.85 3.85 Clamped length L e =1/6 L g L e m 0.65 0.65 Max. perm. bend. mom. M g Nm 730 1040 Ant. up to 20 m above ground Usable bending moment M n Nm 524 803 Intrinsic moment of mast M s Nm 206 237 Ant. over 20 m above ground Usable bending moment M n Nm 446 714 Intrinsic moment of mast M s Nm 284 326 Mast combinations Type STEMA 50/300 +50/200 2 x STEMA 50/300 Load carrying capacity of masts Total length L g m 4.85 5.85 Clamped length L e =1/6 L g L e m 0.80 1.00 Max. perm. bend. mom. M g Nm 1040 1040 Ant. up to 20 m above ground Usable ending moment M n Nm 664 492 Intrinsic moment of mast M s Nm 376 548 Ant. over 20 m above ground Usable bending moment M n Nm 523 286 Intrinsic moment of mast M s Nm 517 754 42

Telescopic masts Type SCHIMA 48/500 SCHIMA 60/601 Order No. 910 820-101 910 818-101 Total length m 4.8 5.8 Pipe Ø/wall thickness, inner mm 40/2.0 48/2.0 outer pipe mm 48/2.0 60/2.5 Number of cable inlets 4 5 Weight kg 11.3 18.4 Length when delivered mm 2.6 3.1 Load carr. cap. of telescopic masts Total length L g m 4.8 5.8 Clamped length L e =1/6 L g L e m 0.80 0.95 Max. perm. bend. moment outer pipe M g Nm 1055 1650 (2058) 1) Ant. up to 20 m above ground Usable bending moment M n Nm 723 1041 (1449) 1) Intrinsic moment of mast M s Nm 332 609 Ant. over 20 m above ground Usable bending moment M n Nm 599 813 (1221) 1) Intrinsic moment of mast M s Nm 456 837 1) The value given in brackets may only be exploited if adequate stability of the building s structure has been verified by calculation. Two-part Inner pipe prevented by a stop from pulling out Swift fixing of the inner pipe with a wing nut Rubber sleeves included Sendzimier hot dip galvanized (SCHIMA 60/601 only hot dip galvanized) Explanations: With a minimum clamped length amounting to 1/6 of the complete pipe s length (as detailed in EN 50083-1): M n = permissible bending moment at the top clamping point, useful for the antennas to be mounted. M s = intrinsic moment of the mast at the top clamping point. M g = maximum permissible bending moment of the mast. 43

Mechanical Accessories Passing through collars for masts Type DAB 50-9 DAB 52-3 N Order No. 601 064-000 601 131-101 Roof coverings for roofs slanted at angles from 5 to 50 Please order sealing cuffs separately For pipe Ø mm up to 60 up to 60 Material weather-proof zinc plate connection black piece plastic lead plate Suitable for universal universal Frankfurt style and others Dimensions mm 400 x 300, 400 x 300, 2 mm thick Connec. 0.6 mm thick, Plate 0.8 mm thick Sealing cuffs Type DAB 60-1 DAB 50-2 DAB 42-2 Order No. 910 822-101 601 026-101 601 025-101 For rain-tight covering of passingthrough collars for masts Weather-proof DAB 60-1: self-sealing with additional tightening strap For pipe Ø mm 32-60 48-57 40-48 For Hirschmann masts STEMA 42/..., STEMA 50/..., STEMA 42/..., STEMA 50/..., SCHIMA48/500 SCHIMA48/500 SCHIMA 48/500, SCHIMA 60/601 Clamps Type BEG 60 U BEG 50 U BEG 42 U Order No. 810 910-100 810 909-100 810 971-100 For securing masts with two hexagon wood screws on straight beams or on beams that slant to the left or right For pipe Ø mm 60 48-50 42 For Hirschmann masts SCHIMA 60/601 STEMA 50/..., STEMA 42/..., SCHIMA 48/500 44

Mast base bracket, mast cap Type MF 63 MAKA 15 Order No 910 781-100 910 231-100 For pipe Ø mm 30-60 32-60 Material black plastic MF 63 For securing masts on horizontal surfaces with 2 hexagon wood screws 8 x 45 The mast is kept at a distance from the floor by a stop thus ensuring that antenna cables can be fed out MAKA 15 End piece for antenna mast Earth strap, rubber cap Type ERB 50 GT 8 V Order No. 910 230-000 910 366-100 For pipe Ø mm max. 60 - For hole Ø mm - max. 6 ERB 50 For equipotential bonding and for earthing in acc. with VDE 0855, Part 1 GT 8 V For sealing off cable inlets Mast accessory sets Type MZ 60 MZ 50 MZ 89 Order No. 910 852-102 910 851-102 913 689-102 ➀ ➂ ➄ ➃ ➁ ➅ Suitable for pipes with Ø mm 60 48-50 89 Mast base (1) MF 63 MF 63 MAFU 89 Fixing clamp (2) BEG 60 U BEG 50 U S 90 Passing though collar for mast (3) DAB 52-3 N DAB 52-3 N BBZ 90 Sealing collar/sealing strap (4) DAB 60-1 DAB 50-2 MAB 60; 2 off Mast cap/pipe cover (5) MAKA 15 MAKA 15 KK 90 Earth strap (6) - - EB 1 For securing masts and passing them through roofs 45

Mechanical Accessories Earth bar Type ES 6 Order No. 942 234-101 For clamping of 10 RF cable screens and one earth wire Individual parts made of steel, surfaces galvanized See EN 50083-1 for details of prescribed use RF cable Ø mm 3-8 Earthing conductor Ø mm min. 2 Support for antennas, window support Type TRAG 53 FETRA 2 Order No. 912 027-100 910 982-501 TRAG 53 For mounting one VHF III or UHF IV/V antenna Made of steel, galvanized (sendzimier) FETRA 2 Made of light metal for smaller antennas Simple installation since the support with the antenna can be mounted to the previously attached support bracket With drip ring Distance to antenna 40 cm from mast - Mast Ø mm max. 60 - Support pipe mm Ø 30 x 1.5 - Wind load N 18 - Protrusion cm - 67 Antenna mast mounts Replacement mounts are available for antennas with longitudinal support 20x20 mm, 12x18 mm and 12 x 12 mm. They can be ordered at our Service Center (for address see Technical Appendix section). 46

Amplifiers Overview of amplifiers House connection amplifiers Line/distribution amplifiers Diplex modules and return path modules for house connection amplifiers, line/distribution amplifiers Multi-band amplifiers Terrestrial amplifiers Amplifiers for satellite and terrestrialsignals Terrestrial antenna amplifiers Remote feed power supply for GPV and GLV series Mast pre-amplifiers Line equalizer 47

Amplifiers Overview House connection amplifiers RC amplifiers eco-power midi-power suitable for digital Primary use Small MATV distribution installations Small and mid MATV distribution sized MATV distrib. installations with installations return path Output stages Push-pull Push-pull Types GHV GHV GRV GPV Standard 10 20 30 630 830 635 835 20 2065 Remotely fed Interstage equalizer Line equalizer For networks 450 MHz up to 606 MHz 862 MHz Return path 5-30 MHz 5-55 MHz 5-65 MHz active Max. output level Two channel assignment IMD2 60 db (EN 45004 A1) dbµv 100 100 102 105 102 110 108 IMD3 60 db (EN 45004 B) dbµv 112 112 114 115 114 118 117 102 116 Cenelec grid CSO 60 db dbµv 92 2) 92 2) 93 2) 96 1) 93 2) 105 1) 104 2) CTB 60 db dbµv 98 2) 98 2) 99 2) 102 1) 99 2) 103 1) 102 2) Basic gain db 10 20 29 29 29 32 31 19 20 115 dbµv 108 Max. output level (CENELEC 42 ch / 862 MHz) GPV high-power + GPV high-power 105 GHV midi-power 95 GHV eco-power 4 8 12 16 20 subscribers 48

BK-Verstärker CATV Broadband Amplifier C3-Amplificateur 14 G 47-862 29/36dB 120 dbµv RC - 30 MHz -1dB RC - 55 MHz -1dB RC - 65 MHz -1dB q RC - Amp. +20 db BK-Verstärker CATV Broadband Amplifier C3-Amplificateur G 47-862 29/36dB 124 dbµv RC - 30 MHz -1dB RC - 55 MHz -1dB RC - 65 MHz -1dB q RC - Amp. +20 db House connection amplifiers Line / distribution amplifiers high-power high-power + 839 851 Large house Large house CATV and broadband cable networks distribution distribution installations installations Push-pull GaAs Power doubler GaAs Push-pull Darlington Push-pull Power power doubler doubler GPV GLV 839 841 851 660 668 860 865 841 F 851 F 660 F 668 F 860 F 865 F 839 I 841 I / F 851 I / F 5) 5) 4) 4) 4) 4) 4) 4) 4) 114 114 117 114 118 114 116 121 122 124 122 126 121 123 109 1) /107 2) 110 1) /108 2) 112 1) / 110 2) 113 1) 116 1) 109 2) 112 2) 109 1) /107 2) 110 1) /108 2) 112 1) / 110 2) 110 1) 114 1) 107 2) 110 2) 30/37 3) 29/36 3) 29/36 3) 28/35 3) 28/35 3) 28/35 3) 28/35 3) 1) Channel load with 29 TV channels up to 606 MHz 2) Channel load with 42 TV channels up to 862 MHz 3) Basic gain can be changed with a jumper, lower gain set in the factory 4) Optional 5) Line equalizer can be changed with a jumper for 606 MHz or 862 MHz Application example 1: House connection point 5 2: House connection amplifier GHV / GPV 3: Return path amplifier GRV 20 / GRV 2065 4: Tap-off ARS 1264 A 5: Antenna outlet socket EDU 04 F 6: Line amplifier GLV 660 F 7: Tap-off AFC 1641 6 7 1 2 3 4 49

Amplifiers Overview Amplifiers for terrestrial signals Antenna amplifiers Remotely fed Antenna amplifier Locally fed Types MPV MPO 11 F 12 F 31 F 32 F 310 F 11 31 Inputs AM - - - - - - - - FM (+ B I on MPV ) - - 1 1 1-1 VHF (B I) - - - - - - - VHF (B III) - - 1 1 1-1 VHF (BI or B III) - - - - - - - UHF - - 1 1 1-1 VHF - UHF (B I-B IV/V) 1 1 - - - 1 - Gain AM db - - - - - - - FM db 23 20 23 20 29 24 22 VHF (B I) db 23 20 23 20 29 24 22 VHF (B III) db 23 20 23 20 29 24 22 VHF (BI or B III) db - - - - - - - UHF db 23 20 23 20 29 24 22 Max. output level AM dbµv - - - - - - - FM dbµv 113 110 113 110 112 110 110 VHF (B I) dbµv 113 110 113 110 112 110 110 VHF (B III) dbµv 113 110 113 110 112 110 110 VHF (BI or B III) dbµv - - - - - - - UHF dbµv 113 110 113 110 112 110 110 Amplifier for terrestrial and satellite signals Super broadband amplifier 47-2400 MHz 50 Types CVE 235 CNV 235 CNV 11 F Main area of application Small SMATV distribution installations Features Coupler satellite/terr. Terrestrial gain Satellite gain Remote feed for LNBs (feed through) Input terrestrial 1 satellite 2 terrestrial + satellite 2 1 Output terrestrial + satellite 2 2 1 Level control, satellite 2 2 - Gain terrestrial db 5 29 12 satellite db 27-35 27-35 13-21

Multi-band amplifiers Terrestrial signal amplifiers 0.15-862 MHz 47-862 MHz GNS CMU 320 A 440 A 445 A 450 A 108 119 128 155 1 1 1 - - - - 1 1 1 1 1 1 1 1-1 1 1 - - - - 1 1 1 1 - - - - - - - - 1 1 (1 ch) 2 (2 ch) 3 (5 ch) 1 1 1 1 2 (8 ch) 3 (9 ch) 3 (8 ch) 2 (5 ch) - - - - - - - - - 1.5 26 26 - - - - 20 27 27 34 4 35 35 35 27 27 34 - - - - 20 27 27 34 - - - - - - - - 28 43 43 43 20 27 27 34 40 53 53 53-113 113 - - - - 109 109 109 116-116 116 116 109 109 116 - - - - 109 109 109 116 - - - - - - - - 106 116 116 116 109 109 109 116 100 116 116 116 Example for the inputs on CMU : 3 (5 ch) = 3 inputs for 5 channels 1 2 4 Application example 1: Multi-band amplifier GNS A or terrestrial signal amplifier CMU 2: Distribution box VEDO 0422 A 3: Tap-off ARS 0912 A / ARS 1412 A / ARS 2012 A 4: Antenna outlet socket EDU 04 F 3 51

Amplifiers eco-power series Without line equalizer For use as post-amplifier in broadband CATV networks after the connection point or in trunk networks Frequency range 5-862 MHz Passive return path 5-30 MHz or 5-65 MHz Line equalizers LES 450, LES 600 and LES 860 can be bolted on RF connections: F-connectors Operating voltage 230 V~ +6%, 10%/50-60 Hz Plastic/metal housing IP 20 Operating temperature 20 C to + 50 C (EN 60065), functional up to +60 C Wall mounting with enclosed screws Meets FN 50083-1, -2, -3 (suitable for digital) Note You will find return path amplifiers GRV 20 and GRV 2065 at the end of this section House connection amplifiers for small house installations Type GHV 10 GHV 10/65 Order No. 944 739-003 944 739-065 Return path 5-30 MHz 5-65 MHz Frequency range forward 47-862 MHz 85-862 MHz Power consumption 3 W Weight 0.35 kg Dimensions 125 x 105 x 63 mm Type GHV 20 GHV 20/65 Order No. 944 731-003 944 731-065 Return path 5-30 MHz 5-65 MHz Frequency range forward 47-862 MHz 85-862 MHz db Attenuator 20 db Power consumption 5 W Weight 0.35 kg Dimensions 125 x 105 x 63 mm Type GHV 30 GHV 30/65 Order No. 944 732-003 944 732-065 Return path 5-30 MHz 5-65 MHz Frequency range forward 47-862 MHz 85-862 MHz db Attenuator 20 db eco-power series accessories Line equalizers LES For compensating frequency-dependent cable attenuation Slope in the respective frequency range can be adjusted RF connections with F-connectors Can be bolted onto the house connection amplifiers GHV 10, GHV 20 and GHV 30 Metal housing Line equalizer LES Power consumption 5 W Weight 0.4 kg Dimensions 125 x 105 x 63 mm 52

RC VHF I-UHF Frequency range MHz 5-30 65 47 85-450 - 606-862 Gain db 0.5 10 Max. output level Two channel assignment IMD2 60 db (EN 45004 A1) dbµv 104 100 IMD3 60 db (EN 45004 B) dbµv 114 112 Cenelec grid CSO 60 db dbµv - 93 1) 92 2) CTB 60 db dbµv - 100 1) 98 2) Stat. grid CSO/CTB 66 db dbµv 89 3) - Noise figure db 6 Return loss db 17 15 13 Frequency range MHz 5-30 65 47 85-450 - 606-862 Gain db 0.5 20 T Max. output level Two channel assignment IMD2 60 db (EN 45004 A1) dbµv 104 100 IMD3 60 db (EN 45004 B) dbµv 114 112 Cenelec grid CSO 60 db dbµv - 93 1) 92 2) CTB 60 db dbµv - 100 1) 98 2) Stat. grid CSO/CTB 66 db dbµv 89 3) - Noise figure db 6 Return loss db 17 16 12 Frequency range MHz 5-30 65 47 85-450 - 606-862 Gain db 1 29 T Max. output level Two channel assignment IMD2 60 db (EN 45004 A1) dbµv 109.5 102 IMD3 60 db (EN 45004 B) dbµv 115 114 Cenelec grid CSO 60 db dbµv - 94 1) 93 2) CTB 60 db dbµv - 101 1) 99 2) Stat. grid CSO/CTB 66 db dbµv 92 3) - Noise figure db 6 Return loss db 17 17 15 1) Channel load with 29 TV channels up to 606 MHz 2) Channel load with 42 TV channels up to 862 MHz 3) Channel load with 36 TV + 24 FM channels up to 450 MHz All values with level control set to 0 db and linear frequency response (0 db equalization) T Input with level control Type LES 450 LES 600 LES 860 Order No. 947 558-001 947 559-001 947 560-001 Frequency range MHz 47-450 47-606 47-862 Adjustable equalization db 18 18 18 Basic attenuation db 1 1 1 (frequency independent) Dimensions mm 44 x 48 x 24 44 x 48 x 24 44 x 48 x 24 53

Amplifiers House connection amplifiers for small house installations eco-power series With line equalizer For use as a post-amplifier in broadband CATV networks after the connection point or in the trunk networks of community antenna systems Transmission range up to 606 MHz or up to 862 MHz Passive return path 5-30 MHz or 5-65 MHz Level control 20 db Integrated line equalizer 18 db GHV 630: for 606 MHz GHV 830: for 862 MHz RF connections: F-connectors Operating voltage 230 V~ +6%, 10%/50-60 Hz Plastic/metal housing IP 20 Wall mounting with accompanying screws Operating temperature 20 C to + 50 C (EN 60065), functional up to +60 C Weight 0.35 kg Dimensions 125 x 105 x 63 Meets EN 50083-1, -2, -3 (suitable for digital) Type GHV 630 GHV 630/65 Order No. 944 736-003 944 736-065 GHV 630 GHV 630/65 Return path 5-30 MHz 5-65 MHz Frequency range forward 47-862 MHz 85-862 MHz RC VHF I - UHF ch 37 Frequency range MHz 5-30 65 47 85 606 Gain db 1 29 T Max. output level Two channel assignment IMD2 60 db (EN 45004 A1) dbµv 105 IMD3 60 db (EN 45004 B) dbµv 115 Cenelec grid CSO 60 db dbµv 96 1) CTB 60 db dbµv 102 1) Stat. grid CSO/CTB 66 db dbµv 92 3) Full assign. CSO/CTB 66 db dbµv 88 4) Noise figure db 6 Return loss db 17 14 14 Power consumption W 5 db Note You will find return path amplifiers GRV 20 and GRV 2065 at the end of this section Type GHV 830 GHV 830/65 Order No. 944 733-003 944 733-065 GHV 830 GHV 830/65 Return path 5-30 MHz 5-65 MHz Frequency range forward 47-862 MHz 85-862 MHz db 1) Channel load with 29 TV channels up to 606 MHz 2) Channel load with 42 TV channels up to 862 MHz 3) Channel load with 36 TV + 24 FM channels up to 450 MHz 4) Any channel load with 60 analog / digital TV channels. The available output level increases by 2 db at an initial equalization of 6 db 5) Any channel load with 80 analog / digital TV channels. The available output level increases by 2 db at an initial equalization of 6 db All values with level control set to 0 db and linear frequency response (0 db equalization) T Input with level control RC VHF I - UHF ch 69 Frequency range MHz 5-30 65 47 85 862 Gain db 1 29 T Max. output level Two channel assignment IMD2 60 db (EN 45004 A1) dbµv 102 IMD3 60 db (EN 45004 B) dbµv 114 Cenelec grid CSO 60 db dbµv 93 2) CTB 60 db dbµv 99 2) Stat. grid CSO/CTB 66 db dbµv 92 3) Full assign. CSO/CTB 66 db dbµv 85 5) Noise figure db 6 Return loss db 17 15 15 Power consumption W 5 54

House connection amplifiers for mid sized house installations Type GHV 635 GHV 635/65 Order No. 944 766-001 944 766-065 GHV 635 GHV 635/65 Return path 5-30 MHz 5-65 MHz Frequency range forward 47-862 MHz 85-862 MHz db RC VHF I - UHF ch 37 Frequency range MHz 5-30 65 47 85 606 Gain db 1 32 T Max. output level Two channel assignment IMD2 60 db (EN 45004 A1) dbµv 110 IMD3 60 db (EN 45004 B) dbµv 118 Cenelec grid CSO 60 db dbµv 105 1) CTB 60 db dbµv 103 1) Stat. grid CSO/CTB 66 db dbµv 103 3) Full assign. CSO/CTB 66 db dbµv 97 4) Noise figure db - 6 Return loss db 17 16 16 Power consumption W 7 Type GHV 835 GHV 835/65 Order No. 944 765-001 944 765-065 GHV 835 GHV 835/65 Return path 5-30 MHz 5-65 MHz Frequency range forward 47-862 MHz 85-862 MHz RC VHF I - UHF ch 69 Frequency range MHz 5-30 65 47 85 862 Gain db 1 31 T Max. output level Two channel assignment IMD2 60 db (EN 45004 A1) dbµv 108 IMD3 60 db (EN 45004 B) dbµv 117 Cenelec grid CSO 60 db dbµv 104 2) CTB 60 db dbµv 102 2) Stat. grid CSO/CTB 66 db dbµv 103 3) Full assign. CSO/CTB 66 db dbµv 96 5) Noise figure db 6 Return loss db 17 15 14 Power consumption W 7 db midi-power series With line equalizer For use as a post-amplifier in broadband CATV networks after the connection point or in the trunk networks of community antenna systems Transmission range up to 606 MHz or up to 862 MHz Passive return path 5-30 MHz or 5-65 MHz Level control 20 db Integrated line equalizer 18 db GHV 635: for 606 MHz GHV 835: for 862 MHz RF connections: F-connectors Operating voltage 230 V~ +6%, 10%/50-60 Hz Plastic/metal housing IP 20 Wall mounting with accompanying screws Operating temperature 20 C to + 50 C (EN 60065), functional up to +60 C Weight 0.7 kg Dimensions 125 x 105 x 63 Meets EN 50083-1, -2, EN 50083-3, quality class 2 (suitable for digital) Note You will find return path amplifiers GRV 20 and GRV 2065 at the end of this section 1) Channel load with 29 TV channels up to 606 MHz 2) Channel load with 42 TV channels up to 862 MHz 3) Channel load with 36 TV + 24 FM channels up to 450 MHz 4) Any channel load with 60 analog / digital TV channels. The available output level increases by 2 db at an initial equalization of 6 db 5) Any channel load with 80 analog / digital TV channels. The available output level increases by 2 db at an initial equalization of 6 db All values with level control set to 0 db and linear frequency response (0 db equalization) T Input with level control 55

BK-Verstärker CATV Broadband Amplifier C3-Amplificateur 14 G 47-862 29/36dB 120 dbµv RC - 30 MHz -1dB RC - 55 MHz -1dB RC - 65 MHz -1dB q RC - Amp. +20 db BK-Verstärker CATV Broadband Amplifier C3-Amplificateur G 47-862 29/36dB 124 dbµv RC - 30 MHz -1dB RC - 55 MHz -1dB RC - 65 MHz -1dB q RC - Amp. +20 db Amplifiers Standard program up to 862 MHz For broadband CATV networks Power doubler GaAs hybrid output stage Locally or remotely fed Two basic gains (configurable, e.g. 29 / 36 db on GPV 841) Can be individually configured using diplex modules return path and forward range 5-30 MHz 47-862 MHz 5-55 MHz 77-862 MHz 5-65 MHz 85-862 MHz Return path (in conjunction with diplex modules) - passive (can be switched off) - active with return path module Integrated line equalizer 0-18 db Equalization, switchable to 606 MHz or 862 MHz Level control 0-20 db Die-cast housing Screw terminal for equipotential bonding on exterior of housing Protection class IP 55, for indoor and outdoor installation RF connections: F-connectors Meets EN 50 082-1, EN 50 083-3, quality class 2 (suitable for digital) Note You will find diplex modules and return path modules after the line / distribution amplifiers GLV House connection amplifiers for large house installations high-power high-power high-power + Type GPV 839 GPV 841 GPV 851 Order No. 944 773-001 944 769-001 944 770-001 839 851 Frequency range MHz 47-862 47-862 47-862 Basic gain low db 30 29 29 high db 37 36 36 Frequency response db ± 1 ± 0.75 ± 0.75 Noise figure db 7 7 7 Output level acc. EN 50083 at 60 db IMD 2nd order dbµv 114 115 117 at 60 db IMD 3rd order dbµv 121 122 124 Cenelec 1) CSO / CTB dbµv 107 108 110 Return loss at input and output db 16 16 16 Group propagation delay 2) ns 15 15 15 Adjustable line equalizer db 0-18 0-18 0-18 Adjustable attenuator db 0-20 0-20 0-20 Test point on output db 30 ±1 30 ±1 30 ±1 Operating voltage (50-60 Hz) V~ 230 +10/-15% 230 +6/-15% 230 +6/-15% Power consumption W 8 14.5 20 Operating temperature acc. EN 60065 C 20 to +60 20 to +55 20 to +55 Functional in the range C 40 to +70 40 to +60 40 to +60 Weight kg approx. 2 approx. 2.5 approx. 2.5 Dimensions W x H x D mm 190 x 115 x 70 190 x 115 x 70 190 x 115 x 70 1) 42 channels, measured data at room temperature, equalizer and level control set to 0 db 2) Group propagation delay lower channel video carrier / color subcarrier (4.43 MHz separation) Special types Versions GPV I All basic units are available as GPV I with additional interstage pre-emphasis (configurable 0 / 7 db) The table shows the data that differ from the basic units Type GPV 839 I GPV 841 I GPV 851 I Order No. 944 773-003 944 769-003 944 770-003 Interstage pre-emphasis db 0 / 7 0 / 7 0 / 7 Test point on input and output db 30 ±1 30 ±1 30 ±1 Versions GPV F The basic units GPV 841 and GPV 851 are available in remotely fed GPV F versions Remote feed over input or output Forwarding of the remote feed voltage Interstage pre-emphasis, configurable The table shows the data that differ from the basic units Type GPV 841 F GPV 851 F Order No. 944 776-001 944 777-001 Interstage pre-emphasis db 0 / 7 0 / 7 Test point on input and output db 30 ±1 30 ±1 Operating voltage (50-60 Hz) V~ 32-65 32-65 Power consumption W 11 14 56

Line/distribution amplifiers up to 606 MHz Type GLV 660 GLV 660 F GLV 668 GLV 668 F Order No. 944 403-001 944 404-001 944 407-001 944 408-001 Frequency range 1) MHz 47-606 Basic gain low db 28 high db 35 Frequency response db ±0.5 Linearity in the TV channel 0.2 db / 0.5 MHz; 0.5 db / 7 MHz Noise figure db 7 Output level acc. EN 50083 at 60 db IMD 2nd order dbµv 114 114 118 118 at 60 db IMD 3rd order dbµv 122 122 126 126 Cenelec 2) CSO dbµv 113 113 116 116 CTB dbµv 110 110 114 114 Return loss on input and output db 20 Group propagation delay 3) ns 10 Interstage pre-emphasis, fixed db 0 / 7 Adjustable line equalizer db 18 Adjustable attenuator db 0-18 Test point db 26 ±1 Operating voltage (50-60 Hz) V~ 230 4) 32-65 230 4) 32-65 Power consumption W 13 13 (at 40 V) 18 18 (at 40 V) Current capacity of the remote feed circuits A - 2-2 Operating temperature range acc. EN 60065 C 20 +55 Functional in the range C 40 +60 Weight kg approx. 2 Dimensions W x H x D mm 190 x 115 x 70 1) Basic unit without diplex module and without active return path module 2) 42 channels at 60 db IMD 3) Group propagation delay from video carrier to color subcarrier 4) +15/ 10% Accessories for GLV Threaded socket PG 11 with inner pin PG 11 M-3,5/12 F: cable side 3.5/12 F-socket, Order No. 980 000-209 PG 11 M-IEC 14 F: cable side threaded IEC-socket M 14, Order No. 960 979-001 PG 11 M-FF (Nr): cable side F-socket, Order No. 960 980-001 Threaded adaptor PG 11-5/8, Order No. 980 000-199 Remote feed power supply SWF 6530, see end of this section Order No. 947 592-001 For use in broadband CATV distribution networks up to 606 MHz Darlington power doubler output stage in GLV 668 (F) Push-pull output stage in GLV 660 (F) Up to 5 units can be cascaded Locally or remotely fed Two basic gains selectable using internal jumpers (interstage) Level control on the input Equalization of frequency-dependent line attenuation, fixed (interstage) and adjustable Can be individually configured using diplex modules return path and forward range 5-30 MHz 47-606 MHz 5-55 MHz 77-606 MHz 5-65 MHz 85-606 MHz Return path (in conjunction with diplex module) - passive (can be switched off) - active with return path module, adjustable attenuator and equalizer GLV F: Remote feed via input, output or loop-through of the remote feed voltage can be selected by repositioning fuses. Additional internal terminals for direct connection of the remote feed voltage Internal IEC test sockets on input and output for forward and return channel measurements Input and output protected against overvoltage RF connections for PG 11 threaded fitting Die-cast housing, protection class IP 65, for installation indoors and outdoors Screw terminal for equipotential bonding on exterior of housing Meets EN 50 082-1, EN 50 083-3, quality class B Note You will find diplex modules and return path modules after the line / distribution amplifiers GLV 57

Amplifiers Line / distribution amplifiers up to 862 MHz Type GLV 860 GLV 860 F GLV 865 GLV 865 F Order No. 944 405-001 944 406-001 944 409-001 944 410-001 For use in broadband CATV distribution networks up to 862 MHz Power doubler output stage in GLV 865 (F) Push-pull output stage in GLV 860 (F) Up to 5 units can be cascaded Locally or remotely fed Two basic gains selectable with internal jumpers (interstage) Level control on the input Equalization of frequency-dependent line attenuation, fixed (interstage) and adjustable Can be individually configured using diplex modules return path and forward range 5-30 MHz 47-862 MHz 5-55 MHz 77-862 MHz 5-65 MHz 85-862 MHz Return path (in conjunction with diplex module) - passive (can be switched off) - active with return path module, adjustable attenuator and equalizer GLV F: Remote feed via input, output or loop-through of the remote feed voltage can be selected by positioning fuses. Additional internal terminal for direct connection of feed voltage Internal IEC test sockets on input and output for forward and return channel measurements Input and output protected against overvoltage RF connections for PG 11 threaded fitting Die-cast housing, protection class IP 65, for installation indoors and outdoors Screw terminal for equipotential bonding on the exterior of housing Meets EN 50 082-1, EN 50 083-3, quality class B Frequency range 1) MHz 47-862 Basic gain low db 28 high db 35 Frequency response db ±0.5 Linearity in the TV channel 0.2 db / 0.5 MHz; 0.5 db / 7 MHz Noise figure db 7 Output level acc. EN 50083 at 60 db IMD 2nd order dbµv 114 114 116 116 at 60 db IMD 3rd order dbµv 121 121 123 123 Cenelec 2) CSO dbµv 109 109 112 112 CTB dbµv 107 107 110 110 Return loss on input and output db 20 Group propagation delay 3) ns 10 Interstage pre-emphasis, fixed db 0 / 7 Adjustable line equalizer db 18 Adjustable attenuator db 0-18 Test point db 26 ±1 Operating voltage (50-60 Hz) V~ 230 4) 32-65 230 4) 32-65 Power consumption W 13 13 (at 40 V) 18 18 (at 40 V) Current capacity of the remote feed circuits A - 2-2 Operating temperature range acc. EN 60065 C 20 +55 Functional in the range C 40 +60 Weight kg approx. 2 Dimensions W x H x D mm 190 x 115 x 70 1) Basic unit without diplex module and without active return path 2) 42 channels at 60 db IMD 3) Group propagation delay from video carrier to color subcarrier 4) +15/ 10% Accessories for GLV Threaded sockets PG 11 with inner pin PG 11 M-3,5/12 F: cable side 3.5/12 F-socket, Order No. 980 000-209 PG 11 M-IEC 14 F: cable side threaded IEC-socket M 14, Order No. 960 979-001 PG 11 M-FF (Nr): cable side F-socket, Order No. 960 980-001 Threaded adaptor PG 11-5/8, Order No. 980 000-199 Remote feed power supply SWF 6530, see end of this section Order No. 947 592-001 58

Modules for house connec. amplifiers GPV and line/distrib. amplifiers GLV Diplex modules GRM 3047 P GRM 5571 P GRM 5577 P GRM 6585 P Order No. 944 412-001 944 432-001 944 413-001 944 416-001 Frequency range return path MHz 5-30 5-55 5-55 5-65 forward path MHz 47-862 70-862 77-862 85-862 Throughpass attenuation return path db 1 1 1 1 forward path db 1 1 1 1 Return loss db 20 18 20 20 Decoupling between forward / return path db 63 63 63 63 Total selection db - 80 - - Operating temperature range C 20 to +80 Diplex modules for house connection amplifiers GPV and line/distribution amplifiers GLV Diplex modules passively divide the frequency range into return path and forward path Return path modules GRM 3005 G GRM 5505 G GRM 6505 G Order-No. 944 411-001 944 415-001 944 419-001 Frequency range MHz 5-30 5-55 5-65 Gain db 20 20 20 Frequency response db 1 1 1 Noise figure db 7 7 7 Output level acc. EN 50083 at 60 db IMD 2nd order dbµv 110 110 110 at 60 db IMD 3rd order dbµv 118 118 118 Return loss at input and output db 20 20 20 Adjustable line equalizer db 0-10 0-10 0-10 Adjustable attenuator db 0-10 0-10 0-10 Current consumption from the internal 24 V supply ma approx. 60 approx. 60 approx. 60 Operating temperature range C 20 to +80 20 to +80 20 to +80 Return path modules for house connection amplifiers GPV and line/distribution amplifiers GLV Equalizer and attenuator on the module input For use with high return path input level Return path modules GRM 2030 G GRM 2055 G GRM 2065 G Order No. 944 414-001 944 421-001 944 420-001 Frequency range MHz 5-30 5-55 5-65 Gain db 20 20 20 Frequency response db 1 1 1 Noise figure db 5 5 5 Output level acc. EN 50083 at 60 db IMD 2nd order dbµv 108 108 108 at 60 db IMD 3rd order dbµv 116 116 116 Return loss at input and output db 20 20 20 Adjustable line equalizer db 0-10 0-10 0-10 Adjustable attenuator db 0-10 0-10 0-10 Current consumption from the internal 24 V supply ma approx. 60 approx. 60 approx. 60 Operating temperature range C 20 to +80 20 to +80 20 to +80 Return path modules for house connection amplifiers GPV and line/distribution amplifiers GLV Equalizer and attenuator on the module output Improved signal-to-noise ratio for RC input signal level below 90 db 59

Amplifiers Multi-band amplifiers 0.15-862 MHz GNS 320 A For small to medium size MATV systems Type GNS 320 A GNS 440A, GNS 445 A, GNS 450 A For medium size MATV systems Order No. 944 652-001 470 174 - - 862 230 87,5 MHz - 108 MHz Common features For amplifying terrestrial signals RF connections: coaxial sockets acc. IEC 169-2 Operating voltage 230 V~ +6%, 10%/50-60 Hz Metal-plastic housing Operating temperature 20 C to +50 C Meets EN 50083-1, -2 Type GNS 440 A Order No. 944 655-001 20 db level control on each input, except AM Power consumption 4 W Dimensions 200 x 105 x 63 mm 470-862 174 47 - - 230 68 0,15 MHz - 108 MHz Type GNS 445 A Order No. 944 656-001 470-862 174-230 47-68 0,15 MHz - 108 MHz 20 db level control on all inputs. External clamp + 24 V for remote feed of remote add-ons (max. 60 ma) Type GNS 450 A Order No. 944 657-001 470-862 174-230 47-68 0,15 MHz - 108 MHz 20 db level control on all inputs. External clamp + 24 V for remote feed of remote add-ons (max. 150 ma) 60

AM FM VHF I VHF III UHF IV/ V Frequency range MHz 0.15-10 87.5-108 47-68 174-230 470-862 Gain db - 20-20 20 Max. output level dbµv - 109 1) - 109 1) 109 1) dbµv 109 2) Noise figure db - 7-7 7 Power consumption W 4 W Dimensions mm 200 x 105 x 63 Frequency range MHz 0.15-10 87.5-108 47-68 174-230 470-862 Gain db 1.5 27 T 27 T 27 T 27 T Max. output level dbµv - 109 1) 109 1) 109 1) 109 1) dbµv 109 2) Noise figure db - 7 7 7 7.5 Power consumption W 4 Dimensions mm 200 x 105 x 63 Frequency range MHz 0.15-10 87.5-108 47-68 174-230 470-862 Gain db 26 T 27 T 27 T 27 T 27 T Max. output level dbµv 113 3) 109 1) 109 1) 109 1) 109 1) dbµv 109 2) Noise figure db - 7 7 7 7.5 Power consumption W min. 6.5 / max. 8.5 Dimensions mm 200 x 105 x 63 Frequency range MHz 0.15-10 87.5-108 47-68 174-230 470-862 Gain db 26 T 34 T 34 T 34 T 34 T Max. output level dbµv 113 3) 116 1) 116 1) 116 1) 116 1) dbµv 116 2) Noise figure db - 7 7 7 7.5 Power consumption W min. 12 / max. 17 Dimensions mm 265 x 135 x 75 1) According to DIN 45 004 B for 66 db IMD and channel load with 2 channels (3rd order interference products) 2) According to DIN 45 004 A1 for 60 db IMD (2nd order interference products) 3) For 66 db harmonic attenuation (ak2 and ak3) at f = 260 khz All values with attenuator T at 0 db 61

Amplifiers Terrestrial signal amplifier 47-862 MHz Type CMU 108 Order No. 960 845-001 Using only one unit it is possible to actively combine all terrestrial signals. Different signal levels from the same or different directions can be set to an uniform level Compact MATV (Master Antenna Television) system that, along with FM signals (passive), can also transmit the VHF band and 8 UHF channels (active). Up to two UHF antennas along with one VHF and one FM antenna can be connected to the CMU 108 Simple programming of the UHF channels with the integrated keypad and digital display Each UHF channel can be separately selected and programmed via a switch Level control for all UHF channels and the VHF range All settings are stored automatically LED display for activated UHF channels An integrated level meter with LED display makes it possible to set the output level without the need for measuring equipment RF connections: F-connectors Wall mounting The post-amplifier CPA 108 can be connected to the output of the CMU 108 with a jumper cable Meets EN 50083-1, -2 VHF UHF FM Frequency ranges MHz 47-230 470-862 87.5-108 Recommended input level for S/N 45 db dbµv 51-91 51-71 Operational input level dbµv 42-91 41-75 Number of inputs 1 2 1 Gain db 28 40 4 Noise factor db < 5 < 7 - Level control adjust. range db 20 + 10 20 Max. output level per channel dbµv 106 100 - for 60 db IMD 1) dbµv up to 117 (with post-amplifier CPA 108) Output level red dbµv > 92 display green dbµv 91 yellow dbµv < 90 Power supply 230 V~ + 6%,-10%, 10 W Operating temperature C 0 to + 50 Weight kg 3 Dimensions H x W x D mm 280 x 250 x 55 1) According to EN 45 004 B (3rd order interference products) and channel load with 2 channels 62

Post-amplifier 47-862 MHz Type CPA 108 Order No. 960 846-001 VHF UHF FM Frequency ranges MHz 47-230 470-862 87.5-108 Gain db 25 25 33 Noise figure db 7 6 7 Adjustable attenuator db 20 20 20 Max. output level for 60 db IMD 1) dbµv 117 117 117 Power supply 230 V~ + 6%,-10%, 8 W Operating temperature C 0 to + 50 Weight kg 0.75 Dimensions mm 185 x 105 x 40 1) According to EN 45 004 B (3rd order interference products) and channel load with 2 channels For additional amplification of the CMU 108 output signal. This combination is suited for larger MATV systems The gain of the VHF, UHF and FM bands can be set independently Separate amplifier for each band LED function indicator Can be connected to the output of the CMU 108 Wall mounting RF connections: F-connectors F-connecting jumper cable included Meets EN 50083-1, -2 63

Amplifiers Terrestrial signal amplifiers Type CMU 119 CMU 128 CMU 155 Order Nos. CCIR Standard B/G 960 885-001 960 886-001 960 887-001 OIRT Standard D/K 960 885-002 960 886-002 960 887-002 CMU 119, CMU 128 and CMU 155 are compact amplifier systems that selectively amplify up to 10 VHF/UHF channels and FM (see the table below Inputs/Channel Configurations ) Signals from up to 5 different aligned TV antennas and one FM antenna can be combined actively with a single unit. In addition, a loop-through input for TV signals of 47-862 MHz is available An Automatic Equalization System (AES) controls the signal level automatically, thus significantly simplifying amplifier adjustment (separate control unit CEB 110 required) The channels are programmed via the separate control unit CEB 110, Order No. 960 888-001 LED for manual adjustment of channel level The number of channels per input is adjusted via jumpers Level control for the output level Remote feed socket 24 V/30 ma for separate mast amplifier Installation indoors RF connections: F-connectors Meets EN 50083-1, -2, -5 (quality class 3), EN 60065 Inputs/channels 1 x FM 1 x FM 1 x FM 3 x UHF/9 channels 3 x UHF/8 channels 2 x UHF/5 channels 1 x VHF/1 channel 2 x VHF/2 channels 3 x VHF/5 channels Possible channel configurations A B C D A B C A B C Inputs FM band 1 1 1 1 1 1 1 1 1 1 UHF 1 5 6 7 8 3 4 6 3 4 5 UHF 2 3 2 1 0 3 2 0 2 1 0 UHF 3 1 1 1 1 2 2 2 - - - VHF 1 1 1 1 1 1 1 1 2 3 4 VHF 2 - - - - 1 1 1 2 1 0 VHF 3 - - - - - - - 1 1 1 64

Technical data for CMU 119, CMU 128, CMU 155 Inputs VHF UHF FM Frequency range MHz 47-230 470-862 87.5-108 Gain db 43 53 35 Min. input level (S/N >30 db) dbµv 42 37.5 - Operational input level dbµv 70-90 60-80 - Maximum input level dbµv 95 85 101 Tuning per channel db 25-20 20 - Attenuator FM input db - - 25 Attenuator output db 20 20 - Selectivity (±20 MHz) db 25 25 - Noise figure db 10 5.5 6 Loop-through input Gain db 17.5 17.5 - Max. input level dbµv 90 90 - Maximum output level 1) dbµv 116 Output level 10 channels dbµv 110 Decoupling between the inputs UHF-UHF db > 30 UHF-VHF/FM db > 60 Operating voltage 230 V~ 15/+10%, 50-60 Hz Power consumption W 48 Operating temperature range C 0 +50 Weight kg approx. 3 Dimensions H x W x D mm 325 x 255 x 70 1) According to EN 45004 B (60dB IMD), FM: EN 45004 B (-30 db) Control unit Type CEB 110 Order No. 960 888-001 For programming channels on the amplifier units CMU 119, CMU 128 and CMU 155 Selected channel and amplifier are displayed Power supply is via connected signal amplifier Cable with connector for connecting to the terrestrial signal amplifier is attached to the control unit as one piece 65

Amplifiers Amplifiers for terrestrial and satellite signals 47-2400 MHz CNV 11 F Remote fed post-amplifier for terrestrial and satellite signals Remote feed for LNBs via the RF cable For individual antenna systems with longer lengths of cable F-connector input and output Power supply for the LNBs and postamplifier is from receiver or multiswitch Line equalizer LES 2020 F for the compensation of the frequencydependent cable attenuation in the distribution network at the end of this section Meets EN 50083, Part 2 Type CNV 11 F Order No. 947 764-001 47-2400 MHz 47-2400 MHz 13-18 V Type CVE 235 CVE 235 For the amplification and combining of satellite signals in the 1st IF band (950-2400 MHz) and of terrestrial signals (47-862 MHz) For the reception of analog and digital signals One input each for horizontal and vertical polarized satellite signals. The terrestrial signal is passively fed-in on both outputs via an additional input Adjustable attenuator 20 db for Sat One output each for - horizontal satellite signals + terr. - vertical satellite signals + terr. For the remote feed of receiving systems via the satellite input (13 V / 18 V). Suitable for twin LNBs Meets EN 50 083-1, -2 Order No. 947 642-001 950-2400MHz (V) 950-2400MHz (H) 47-862 MHz 13 V 18 V 0-20 db db 47-2400 MHz (V) db ~ 47-2400 MHz (H) 0-20 db CNV 235 Post-amplifier for the compensation of the attenuation losses in the distribution network Selective signal amplification of the terrestrial and two satellite signals 20 db level control for each amplifier Power supply via the DC input using power supply included Meets EN 50083-1, -2 Type CNV 235 Order No. 947 643-001 0-20 db 47-2400 MHz V H db db Common features RF connections: F-connectors Metal housing for indoor installation Operating temp. 20 C to +60 C V H 47-2400 MHz 66

VHF I-UHF SAT Frequency range MHz 47-862 950-2150 2150-2400 Gain db 12 13-21 20 Max. output level dbµv 95 1) 103 3) 103 3) dbµv 113 2) 115 4) 113 4) Noise figure db 5 6 6 Remote feed voltage, current 13-18 V, max. 450 ma Power consumption W approx. 0.6 Dimensions mm 80 x 44 x 25 Frequency range MHz 47-862 950-2150 2150-2400 Gain db - 30-35 27 Throughpass attenuation db 5 - - Equalization db - 5 - Decoupling SAT/SAT db - 60 55 Max. output level dbµv - 110 3) 107 3) dbµv - 121 4) 118 4) Noise figure db - 8 - Return loss input db 10 9 7 output db 13 10 8 Operating voltage 230 V~ ±10% / 50-60 Hz Current output to LNBs, max. 550 ma, distributed across both inputs Weight kg 1.6 Dimensions W x H x D mm 348 x 115 x 83 Frequency range MHz 47-862 950-2150 2150-2400 Gain db 29 30-35 27 Equalization db - 5 - Decoupling to other planes input to input db 60-55 60 55 output to output db 20-18 55 55 input to input db - 60 55 Max. output level dbµv 110 1) 110 3) 107 3) dbµv 117 2) 121 4) 118 4) Noise figure db 4-5 8 - Return loss input db 12 10 8 output db 13 10 8 Operating voltage 230 V~ ±10% / 50-60 Hz Weight kg 1.2 Dimensions W x H x D mm 285 x 115 x 83 1) According to EN 50083, Part 3 for 2nd order interference products at 60 db IMD 2) According to EN 50083, Part 3 for 3rd order interference products at 60 db IMD 3) According to EN 50083, Part 3 for 2nd order interference products at 35 db IMD 4) According to EN 50083, Part 3 for 3rd order interference products at 35 db IMD, corresponds to DIN 45004 B All values with level control at 0 db and linear frequency response (0 db equalization) 67

Amplifiers Remotely fed antenna amplifiers 47-862 MHz Amplifier VHF I-UHF IV/V Frequency range 47-862 MHz Remote fed via output Power supply MPN 201 can be connected directly, (locally fed) + 15 V terminal for feed to active units connected ahead of the amplifier RF connections: F-connectors Metal housing for indoor installation Black plastic end brackets for wall mounting Fixing screws included Type MPV 11 F MPV 12 F Order No. 944 780-001 944 781-001 VHFI-UHF IV/V, FM Output 2 (only MPV 12) MPN 201 15 V = 220 V ~ Output Frequency range VHF I - UHF IV/V VHF I - UHF IV/V Channels ch 2-69 ch 2-69 Gain db 23 20 Max. output level 1) dbµv 113 110 Noise figure db 4.5 4.5 Current consumption at 15 V= ma 110 110 Dimens. (w/o power supply) mm 135 x 110 x 45 135 x 110 x 45 Type MPV 31 F Order No. 944 782-001 UHF IV/V VHF III VHF I, FM MPN 201 15 V = 220 V ~ Output Frequency range VHF I FM VHF III UHF IV/V Channels ch 2-4 ch 5-12 ch 21-69 Gain db 23 23 23 23 Max. output level 1) dbµv 113 113 113 113 Noise figure db 4.5 4.5 4.5 4.5 Current consumption at 15 V= ma 110 Dimens. (w/o power supply) mm 135 x 110 x 45 Type MPV 32 F Order No. 944 783-001 UHF IV/V VHF III VHF I, FM MPN 201 15 V = Output 2 220 V ~ Output 1) According to DIN V VDE 0855, Part 10 for 60 db IMD (3rd order interference products) in accordance with DIN 45004 B and use of 2 channels Frequency range VHF I FM VHF III UHF IV/V Channels ch 2-4 ch 5-12 ch 21-69 Gain db 20 db 20 db 20 db 20 db Max. output level 1) dbµv 110 110 110 110 Noise figure db 4.5 4.5 4.5 4.5 Current consumption at 15 V= ma 110 Dimens. (w/o power supply) mm 135 x 110 x 45 68

Type MPV 310 F Order No. 944 784-001 UHF IV/V VHF III VHF I, FM T T T MPN 201 15 V = 220 V ~ Output Frequency range VHF I T FM VHF III T UHF IV/VT Channels ch 2-4 ch 5-12 ch 21-69 Gain db 29 29 29 29 Max. output level 1) dbµv 112 112 112 112 Noise figure db 6 6 6 6 Current consumption at 15 V= ma 100 Dimens. (w/o power supply) mm 135 x 110 x 45 1) According to DIN V VDE 0855, Part 10 for 60 db IMD (3rd order interference products) in accordance with DIN 45004 B and use of 2 channels Amplifier VHF I-UHF IV/V Frequency range 47-862 MHz Remote fed via output Power supply MPN 201 can be directly connected (locally fed) + 24 V terminal for feed to units connected ahead of the amplifier Remote feed of mast amplifier via input possible 18 db level control on the input for each band RF connections: F-connectors Metal housing for indoor installation Black plastic end brackets for wall mounting Fixing screws included Remote feed power supply for antenna amplifiers Type MPN 201 F Order No. 944 779-001 Frequency range MHz 0.5-862 Throughpass attenuation db 1 Output voltage V= 15 (minus to ground) Output current, max. ma 200 Dimensions mm 115 x 105 x 45 For the local or remote feed of the Mini-Power amplifier MPV Output voltage electronically stabilised and short circuit proof With built-in remote feed voltage coupler One coaxial output Supply voltage 230 V~/50 Hz. Mains cable approx. 1 m long with Euro plug Metal housing for indoor installation Wall mounting on the plastic parts of the housing using the screws included Quick connector included 69

Amplifiers Locally fed antenna amplifiers 47-862 MHz Type MPO 11 MPO 31 Order No. 981 000-023 981 000-024 MPO 11 Locally fed amplifier 1 input for FM, VHF I - UHF V Integrated totally insulated power supply MPO 31 Locally fed amplifier 3 inputs for FM, VHF III and UHF IV-VHF V Integrated totally insulated power supply Inputs 1 FM, VHF I - UHF V FM 2 - VHF III 3 - UHF IV - V 1 output FM, VHF I - UHF V FM, VHF III, UHF IV - V Gain db 24 22 Max. output level dbµv 113 110 Noise figure db 4.5 4.5 Polarity (minus to ground) V= 24 24 Current consumption ma approx. 110 approx. 110 Connectors F-sockets F-sockets Supply voltage 230 V~, 50 Hz 230 V~, 50 Hz Power consumption W approx. 4 approx. 4 Dimensions mm 138 x 112 x 49 138 x 112 x 49 Empty mast housing Type MLGH 1 For housing the amplifier series MPV Plastic housing suitable for outdoor installation For installation on the wall or on the mast up to Ø 50 mm Scope of delivery: angled KOS connector and angled KOK connector (IEC) Dimensions H x W x D 170 x 160 x 75 mm Order No. 974 117-001 70

Return path amplifiers Type GRV 20 GRV 2065 Order No. 944 746-003 944 746-065 GRV 20 GRV 2065 Return path, active 5-30 MHz 5-65 MHz Frequency range forward, passive 47-862 MHz 85-862 MHz db RC VHF I - UHF C 69 Frequency range MHz 5-30 65 47 85 862 Gain db 19 20 T 0.5 Max. output signal dbµv 102 1) 116 1) Noise figure db 8 6 Power consumption W 3 5 Weight kg 0.35 0.45 Dimensions mm 190 x 135 x 75 1) 60 db IMD3 in accordance with EN 45004 B House connection point GHV HP LP HP GRV 20 LP 47 862 MHz HP 4 30 MHz LP to indoor distribution network Return path amplifiers Can be used as return path amplifiers for interactive broadband CATV house distribution networks Can be combined with all house connection amplifiers GHV 20 db level control GRV 2065 also with equalizer Operating voltage 230 V~ +6%, 10%/50-60 Hz Plastic/metal housing IP 20 Wall mounting with screws included Operating temperature 20 C to +50 C Remote feed power supply Type SWF 6530 Order No. 947 592-001 Operating voltage V~ 230 or 240 (switchable) +6%, 10% / 50-60 Hz Output voltage, switchable V~ 42 50 58 65 Output current, max. A 4.75 4.0 3.45 3.05 Power consumption, max. VA 200 Operating temperature C 20 to +50 Weight kg 5.33 Dimensions mm 170 x 188 x 85 For supplying power to remote fed amplifiers in distribution networks, such as the - GPV series - GLV series 4 selectable output voltages Output: IEC threaded connector M 14/1 (plug with cable included) Control output: 4 mm round socket Short circuit proof by means of electronic output protection Indoor installation on the wall Mains cable approx. 1.5 m long with earthed plug Protection class 1, protection class IP 65 Meets EN 60 065, EN 50083-1,-2 Accessories Power inserter CA 1065-14 for 5/8" connector (to 1 GHz) Order No. 980 000-377 Fitting 5/8 M-AC Order No. 980 000-391 71

Amplifiers Mast pre-amplifier set 47-862 MHz Type APS 330 Order No. 944 574-001 APS 330 Comprising - Remote fed multi-band amplifier SNF 330 - Short circuit proof power supply SNN 250 - Mast mount SNO-U 40 Multi-band amplifier SNF 330 Low noise pre-amplifier in sealed metal housing with weather-proof plastic outer housing for mast mounting To be used near the antenna One input each for VHF I/FM, VHF III, UHF IV/V Remote feed from power supply via the RF cable Please order connector KOS 1 Z for the power supply separately Meets EN 50083-1, -2 Multi-band amplifier Frequency range MHz 47-108 174-230 470-862 Gain db 24 23 24 Output level, max. dbµv 98 97 98 Noise figure db 2.6 2.7 3.3 Remote feed voltage/current approx. 13 V / approx. 30 ma Operating temperature C 20 to +60 Dimensions mm 130 x 115 x 70 Power supply Operating voltage 230 V~ +6%, 10%/50-60 Hz Power consumption W approx. 2 Output voltage/current V approx. 13 / approx. 30 ma Throughpass attenuation db 0.5 Accessories for amplifiers Type LES 2020 F Order No. 947 589-001 Attenuation curve LES 2020 F 0 0 250 500 750 1000 1250 1500 1750 2000 f/mhz LES 2020 F 40 2150 MHz Line equalizer 40-2150 MHz For the compensation of frequencydependent cable attenuation Use e.g. with amplifiers CVE With DC throughpass Please order adaptor F-IEC separately (SBFC 01, see Connectors section) RF connections: F-connectors Meets EN 50083-2 10 20 30 D/dB Frequency range MHz 40 950 2150 Throughpass attenuation db 21 12 2 Max. remote feed current 1 A/24 V DC Operating temperature C 20 to +60 Dimensions mm 90 x 47 x 20 40 2150 MHz 72

Multiswitches Overview of multiswitches Special switches, switching relays Single switches and cascade switches for 3 cable systems Single switches and cascade switches for 5 cable systems Single switches and cascade switches for 9 cable systems 73

Multiswitches Overview 2 cable system, 2 satellite 3 cable system, 2 satellite inputs + inputs, indiv. and cascade terrestrial, individual Types CKR CKR 3121 3161 2400 2402 3400 F 3041 3081 3121 3161 Frequency range MHz 47-47- 47-47- 47-47- 47-2050 2050 2050 2300 2300 2300 2300 Number of inputs 2 2 3 3 3 3 3 Number of subscribers 4 4 4 4 8 12 16 Number of cascadable - 2 - - - - - outputs Switching voltage V 13/18 13/18 13/18 13/18 13/18 13/18 13/18 khz Multiswitch, individual Multiswitch, cascadable Input amplifier Post -amplifier Locally fed Remotely fed What is DiSEqC (Digital Satellite Equipment Control)? DiSEqC is a newly developed system that makes it possible to choose between the reception of more than 4 satellite polarization planes. The previous criteria for making the selection - between horizontal or vertical polarization was the switching voltage - 13/18 V - between upper or lower band was the 22 khz signal. These signals were permanently transmitted over the RF cable. A further selection criterion became necessary to make it possible to select further polarization planes. And in the future the number of selection criteria could well increase considerably further. DiSEqC was developed to bring a halt to this expansion in the number of selection criteria and to create a system that is as simple as possible, but offers the capability of being expanded in the future, and is thus safeguarded in terms of future developments. DiSEqC replaces the previous selection criteria and expands them considerably. The basis for this expansion is a procedure in which digital information is transmitted from the receiver to the receiving system or multiswitch. The 22 khz signal already in use is used as the carrier signal. In order, for example, to implement the selection of a satellite polarization plane, the carrier is modulated with digital information. This information is then sent to the switching unit only once. The selection of another satellite plane is performed in a similar manner, only with different digital information. If DiSEqC is to be used, the individual components, e.g. multiswitch and receiver, must be DiSEqC compatible. The previous selection criteria can continue to be used since a 22 khz carrier that is permanently switched on or off does not contain digital information. 74

5 cable system, 4 satellite inputs + 5 cable system, 4 satellite inputs + terrestrial, individual terrestrial, cascade CKR... CVE CVE CNV CNV CMK CMK 5041 5061 5081 5121 5161 5510 5520 5510 5520 5405 5805 47-47- 47-47- 47-47- 47-47- 47-47- 47-2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 2400 5 5 5 5 5 5 5 5 5 5 5 4 6 8 12 16 - - - - 4 8 - - - - - 5 5 5 5 5 5 13/18 13/18 13/18 13/18 13/18 13/18* 13/18* - - 13/18 13/18 0/22 0/22 0/22 0/22 0/22 - - - - 0/22 0/22 * LNB supply 9 cable system, 8 satellite inputs + 9 cable system, 8 satellite terrestrial, individual inputs + terrestrial, cascade Types CKR CVE CMK CNV 9400 ND 9600 ND 9800 ND 9120 ND 9160 ND 9409 ND 9409 D 9009 ND Frequency range MHz 47-47- 47-47- 47-47- 47-47- 2300 2300 2300 2300 2300 2300 2300 2300 Number of inputs 9 9 9 9 9 9 9 9 Number of subscribers 4 6 8 12 16 4 4 - Number of cascadable - - - - - 9 9 9 outputs Switching voltage V 13/18 13/18 13/18 13/18 13/18 13/18* 13/18 13/18 khz 0/22 0/22 0/22 0/22 0/22-0/22 0/22 Tone Burst, DiSEqC Tone Burst, DiSEqC Multiswitch, individual Multiswitch, cascadable Input amplifier Post-amplifier Locally fed Remotely fed * LNB supply 75

Multiswitches Switching relays Common features RF connections: F-connector Meets EN 50083-1, -2 Type CKR 12 A CKR 21 DD CBG 12 D Order No. 981 000-331 981 000-486 981 000-485 Switching relay CKR 12 A for the connection of a digital receiver For analog and digital signals For switching one satellite plane to two satellite receivers, e.g. digital receiver (d-box) and analog receiver The receiver on output B (digital receiver) receives the satellite signal as soon as it is switched on. If switched off, the receiver on output A receives LNB or Multiswitch CS... C LNB or Multiswitch CS... C CS... C CKR 21 DD the signal Add-on unit to the input of the satellite CGB 12 D Tone Burst Generator receiver Remotely fed via the RF cable Internal relaying of the 13/18 V remote feed voltage and the 22 khz switching signal Metal housing for wall mounting CKR 12 A Digital (has priority) Analog CKR 21 DD (Tone Burst, 22 khz) G 13/18V 22 khz 5-12 V Actuation indoors Switching relay CKR 21 DD for 22 khz switching signal or tone burst Used as individual unit, for analog and digital signals For selecting one of two satellite planes Selection is controlled by the receiver with - a tone burst signal or - 22 khz switching signal Selection command changed from tone burst to 22 khz switching signal using sliding switch The tone burst signal generator CBG 12 D can be added to the inputs of receivers that are not capable of generating a tone burst Add-on unit to the input of the satellite receiver or direct connection to the down lead Remotely fed via the RF cable Internal relaying of the 13/18 V remote feed voltage and the 22 khz switching signal (only useful when used with tone burst switching) to the LNBs Metal housing with plastic brackets for installation indoors Generator CBG 12 D for the generation of a tone burst signal For generating a tone burst signal for switching, e.g. for the switching relay CKR 21 DD For upgrading a receiver that is not equipped with tone burst Add-on unit to the input of the Frequency range MHz 47-2200 47-2300 47-2300 Throughpass attenuation db 1.5 1.5 1 Decoupling 47-862 MHz db 25 30-950-2300 MHz db 25 30 - Switching command by 0 or 13-18 V Tone burst signal or 5/12 V from receiver 22 KHz signal or manually via (adjustable) sliding switch Operating voltage V 13-18 13-18 13-18 Current consumption at 18 V ma 100 35 16 Remote feed current, max. ma 400 450 500 at input/output Operating temperature C 30 to +60 30 to +60 20 to +60 Weight g 110 140 140 Dimensions W x H x D mm 80 x 75 x 30 83 x 74 x 42 83 x 74 x 42 satellite receiver The tone burst signal is controlled by - a 5/12 V voltage from the receiver or - manually via a sliding switch on the unit 5/12 V feed via a permanently connected cable with plug Internal relaying of the 13/18 V remote feed voltage and the 22 khz switching signal Metal housing with plastic brackets for installation indoors 76

Two and three cable system for 4 subscribers Type CKR 2400 CKR 2402 CKR 3400 F Order No. 947 526-001 947 525-001 947 500-001 Input 1 CKR 2400 Input 2 47-2050 MHz (from Input 1 or 2) 13 / 18 V Input 1 Loop-through output 1 2 CKR 2402 Input 2 47-2050 MHz (from Input 1 or 2) 13 / 18 V 950-2050 MHz 47-862 MHz 1 2 950-2050 MHz 1 or 2 and 47-862 MHz 950-2050 MHz 13 / 18 V Common features: For analog signals For the selection of one of two satellite planes, independent of any of the receivers connected Controlled using the 13/18 V LNB supply voltage from the receiver over the RF cable Metal housing for wall mounting indoors Remotely fed over the RF cable RF connections with F-connector Meets EN 50083-1, -2 Frequency range MHz 47-2050 47-2050 47-862 950-2050 Gain db - - - 3.5 Tap-off attenuation db 10 14 - - Throughpass attenuation db - 4±1.5 16 - Noise figure db - - - 6 Max. output level dbµv - - - 92 1) Decoupling input 1/input 2 db 26 26-26 between outputs db 18 18 32 20 Switching voltage for selecting input 1 V 13 (11-14.5) 13 (11-14.5) - 13 (13-14) input 2 V 18 (15.9-19) 18 (15.9-19) - 18 (17-19) Current consumption, max. ma 40 40-70 Rem. feed curr., max. per input ma - - - 400 Operating temperature C 20 to +60 20 to +60 20 to +60 Dimensions mm 165 x 105 x 24 165 x 105 x 24 150 x 110 x 28 1) In accordance with EN 50083-3 at 35 db IMD (3rd order interference products) Two cable system, cascadable, for 4 subscribers CKR 2400, CKR 2402 Cascadable for floor star distribution CKR 2402: with throughpass for both planes. Further switches CKR 2402 or CKR 2400 can be connected CKR 2400: without throughpass. For use on the end of a cascade Remote supply of the LNBs, e.g. via CVE 235 Three cable system (with terrestrial input) for 4 subscribers CKR 3400 F Used as single unit Separate input for feeding in terrestrial signals Internal relaying of the remote feed voltage to the LNBs 77

Multiswitches Three cable system (with terrestr. input) for 4 and 8 subscribers Type CKR 3041 CKR 3081 Order No. 981 000-513 981 000-514 Fig.: CKR 3081 Used as single unit, 3 inputs, for analog or digital signals For the selection of one of two satellite planes, independent of any of the receivers connected Selection using the 13/18 V switching voltage from the receiver via the down lead Connection of 4 receivers with CKR 3041 8 receivers with CKR 3081 Separate input for feeding in terrestrial signals and permanent relaying to all subscribers Active in the satellite and terrestrial range for compensation of distribution attenuation Locally fed LNBs supplied from the multiswitch Metal housing with plastic side brackets for installation indoors RF connections with F-connectors Meets EN 50083-1, -2 Terr: 47-862 MHz Sat: 950-2300 MHz S: switching command 13/18 V Terr Sat H V Sat/Terr S CS 322 C/CS 348 C or Hit CS 320/Hit CS 400 CKR 3041 = ~ Sat H V Sat/Terr CKR 3081 Frequency range MHz 47-862 950-2300 47-862 950-2300 Throughpass attenuation db 0-2 4-6 0-2 8-10 Max. perm. output level dbµv 95 1) 90 2) 88 1) 85 2) Decoupling H/V db > 20 > 20 > 20 > 20 Switching voltage for selecting from vertical input V - 13-13 horizontal input V - 18-18 Operating voltage V 230 V ~ ±10% 230 V ~ ±10% Remote feed current, max. ma 700 700 Operating temperature C 20 to +60 20 to +60 Dimensions W x H x D mm 300 x 80 x 115 400 x 80 x 115 1) In accordance with EN 50 083-3 at 60 db IMD (3rd order interference products) 2) In accordance with EN 50 083-3 at 35 db IMD (3rd order interference products) Terr S CS 322 C/CS 348 C or Hit CS 320/Hit CS 400 = ~ 78

Three cable system (with terrestr. input) for 12 and 16 subscribers Type CKR 3121 CKR 3161 Order No. 981 000-515 981 000-516 Fig.: CKR 3121 Terr: 47-862 MHz Sat: 950-2300 MHz S: switching command 13/18 V Terr Sat Sat/Terr S CKR 3121 Frequency range MHz 47-862 950-2300 47-862 950-2300 Throughpass attenuation db 2-4 10-12 4-6 6-8 Max. perm. output level dbµv 88 1) 85 2) 88 1) 85 2) Decoupling hor./vert. db > 20 > 20 > 20 > 20 Switching voltage for selecting from vertical input V - 13-13 horizontal input V - 18-18 Operating voltage V 230V ~ ±10% 230V ~ ±10% Remote feed current, max. ma 700 700 Operating temperature C 20 to +60 20 to +60 Dimensions W x H x D mm 400 x 80 x 115 468 x 80 x 115 1) In accordance with EN 50 083-3 at 60 db IMD (3rd order interference products) 2) In accordance with EN 50 083-3 at 35 db IMD (3rd order interference products) H 8 CS 322 C/CS 348 C or Hit CS 320/Hit CS 400 V = ~ Terr Sat Sat/ Terr S H V CKR 3161 12 CS 322 C/CS 348 C or Hit CS 320/Hit CS 400 = ~ Used as single unit, 3 inputs, for analog or digital signals For the selection of one of two satellite planes, independent of any of the receivers connected Selection using the 13/18 V switching voltage from the receiver via the down lead Distribution to 12 receivers with CKR 3121 16 receivers with CKR 3161 Separate input for feeding in terrestrial signals and permanent relaying to all subscribers Active in the satellite and terrestrial range for compensation of distribution attenuation Locally fed LNBs supplied from the multiswitch Metal housing with plastic side brackets for installation indoors RF connections with F-sockets Meets EN 50083-1, -2 79

Multiswitches Five cable system (with terrestr. input) for 4, 6 and 8 subscribers Type CKR 5041 CKR 5061 CKR 5081 Order No. 947 640-002 947 652-002 947 637-002 Used as single unit, 5 inputs, for analog and digital signals For selecting one of four satellite planes independent of any of the receivers connected, e.g. H/low band or H/high band or V/low band or V/high band Selection via the switching voltage from the receiver using 13/18 V and 0/22 khz over the RF cable Connection of 4 subscribers with CKR 5041 6 subscribers with CKR 5061 8 subscribers with CKR 5081 Equipment for distribution to 12 and 16 subscribers can be found on the following page Separate input for feeding in terrestrial signals and permanent relaying to all subscribers Active in the satellite range to compensate the distribution attenuation Locally fed LNBs supplied from the multiswitch Metal housing with plastic side brackets for installation indoors RF connections with F-connector Meets EN 50083-1, -2 For high reliability of the digital electronics, all multiswitches in the five cable system are equipped with the high-tech ASIC chip Terr: 47-862 MHz Sat: 950-2400 MHz F: remote feed voltage S: switching command 13/18 V 0/22 khz Fig.: CKR 5041 Terr Sat F Sat/Terr S CKR 5041 Frequency range MHz 47-862 950-2400 47-862 950-2400 47-862 950-2400 Atten. inputs LNB 1-4/output db 40 6 40 6 40 7 Atten. terr. input/output db 0 15-25 0 15-25 0 15-25 Decoupling vert./horiz. -input LNB 1-4/output db - 25-25-20-25-20 -input LNB/input LNB db - 26-30 - 30 Decoupling between outputs db 20 30 20 30 20 30 Max. output level dbµv 94 1) 90-94 2) 94 1) 90-94 2) 94 1) 90-94 2) Switching voltage vert./horiz. V 13/18 13/18 13/18 Switch.commandlow/high bandkhz 0/22 0/22 0/22 Operating voltage V 230 V~ ±10% 230 V~ ±10% 230 V~ ±10% Remote feed current, max. ma 700 700 700 Operating temperature C 20 to +60 20 to +60 20 to +60 Dimensions W x H x D mm 300 x 80 x 115 350 x 80 x 115 350 x 80 x 115 Weight g 1400 1480 1500 1) In accordance with EN 50 083-3 at 60 db IMD (3rd order interference products) 2) In accordance with EN 50 083-3 at 35 db IMD (3rd order interference products) CS 348 C or Hit CS 400 = ~ Terr Sat F Sat/Terr Fig.: CKR 5081 CKR 5061 CS 348 C or Hit CS 400 S = ~ Terr Sat H V Sat/Terr CKR 3081 S CS 322 C/CS 348 C or Hit CS 320/Hit CS 400 = ~ 80

Five cable system (with terrestr. input) for 12 and 16 subscribers Type CKR 5121 CKR 5161 Order No. 947 653-002 947 654-002 Terr: 47-862 MHz Sat: 950-2400 MHz F: remote feed voltage S: switching command 13/18 V 0/22 khz Terr Sat F Sat/Terr S Fig.: CKR 5161 CKR 5121 8 CS 348 C or Hit CS 400 Frequency range MHz 47-862 950-2400 47-862 950-2400 Atten. input LNB 1-4/out. 1-4 db 40 6 40 6 Atten. terr. input/output 1-4 db 0 5-25 0 15-25 Decoupling vert./horiz. - input LNB 1-4/out. 1-4 db - 25-20 - 25-20 - input LNB/input LNB db - 30-30 Decoupling between outputs db 20 30 20 30 Max. output level dbµv 94 1) 90-94 2) 94 1) 90-94 2) Switching voltage vert./horiz. V 13/18 13/18 Switch.commandlow/high bandkhz 0/22 0/22 Operating voltage V 230 V~ ±10% 230 V~ ±10% Remote feed current, max. ma 700 700 Operating temperature C 20 to +60 20 to +60 Dimensions W x H x D mm 400 x 80 x 115 468 x 80 x 115 Weight g 1580 1600 1) In accordance with EN 50 083-3 at 60 db IMD (3rd order interference products) 2) In accordance with EN 50 083-3 at 35 db IMD (3rd order interference products) = ~ Sat/ Terr Terr Sat F S CKR 5161 12 CS 348 C or Hit CS 400 = ~ Used as single unit, 5 inputs, for analog and digital signals For selecting one from four satellite planes independent of any of the receivers connected, e.g. H/low band or H/high band or V/low band or V/high band Selection via the switching voltage from the receiver using 13/18 V and 0/22 khz over the RF cable Connection of 12 subscribers with CKR 5121 16 subscribers with CKR 5161 Equipment for distribution to 4, 6 and 8 subscribers can be found on the previous page Separate input for feeding in terrestrial signals and permanent relaying to all subscribers Active in the satellite and terrestrial range to compensate the distribution attenuation Locally fed LNBs supplied from the multiswitch Metal housing with plastic side brackets for installation indoors RF connections using F-connectors Meets EN 50083-1, -2 For high reliability of the digital electronics, all multiswitches in the five cable system are equipped with the high-tech ASIC chip 81

Multiswitches Common features: For the reception of analog and digital signals Power supplied via the built-in power supply Down leads from the feed-in amplifiers CVE 5510 and CVE 5520 are voltage free Metal housing with plastic side brackets for installation indoors Inputs and outputs: F-connectors Meets EN 50 083-1, -2 Feed-in amplifiers Used as feed-in for the multiswitch five cable system Separate input for feeding in terrestrial signals and separate distribution Transmission of the remote feed voltage over the input to the LNB Cascadable with the multiswitches CMK 5405 or CMK 5805 and the post-amplifiers CNV 5510 or CNV 5520 Level control for all inputs on CVE 5520 only Five cable system, cascadable, feed-in amplifier and post-amplifier Feed-in amplifier Type CVE 5510 CVE 5520 Order No. 947 635-002 947 620-002 CS 348 C or Hit CS 400 Terr remote feed voltage Sat/Terr V H V H = CVE 55x0 ~ Sat/Terr Frequency range MHz 47-862 950-2400 47-862 950-2400 Gain db 8-10 8-12 19-23 22-26 Noise figure db 6 3,5 5 7 Equalization db 1 4 3 4 Decoupling vert./ - sat./sat. db 45 35-30 45 35-30 horiz. - terr./sat. db 40 30 40 30 Max. output level dbµv 102 1) 93 3) 102 1) 102 3) dbµv 114 2) 100 4) 114 2) 114 4) Max. rem. feed current for LNBs ma 700 600 Operating voltage 230 V ~ ± 10%, 50-60 Hz 230 V ~ ± 10%, 50-60 Hz Operating temp. (EN 60065) C 20 to +60 20 to +60 Weight kg 1.5 1.6 Dimensions W x H x D mm 348 x 115 x 83 348 x 115 x 83 Post amplifier Type CNV 5510 CNV 5520 Order No. 947 636-002 947 634-002 CMK 5805 CNV 55x0 = ~ Sat/Terr CMK 5405 Sat/Terr Post-amplifier For post amplifying 4 satellite IF signals and terrestrial signals Satellite IF signals and terrestrial signals are amplified individually and distributed Cascadable with the feed-in amplifiers CVE 5510 or CVE 5520 and the Multiswitches CMK 5405 or CMK 5805 Level control for all inputs on CNV 5520 and terrestrial input on CNV 5510 only 82 Frequency range MHz 47-862 950-2400 47-862 950-2400 Gain db 8-10 8-12 19-23 22-26 Noise figure db 6 3.5 5 7 Equalization db 1 4 4 4 Decoupling vert./ - sat./sat. db 45 35-30 45 35-30 horiz. - terr./sat. db 40 30 40 30 Max. output level dbµv 102 1) 93 3) 102 1) 102 3) dbµv 114 2) 100 4) 114 2) 114 4) Operating voltage 230 V ~ ± 10%, 50-60 Hz 230 V ~ ± 10%, 50-60 Hz Operating temp. (EN 60065) C 20 to +60 20 to +60 Weight kg 1.5 1.6 Dimensions W x H x D mm 348 x 115 x 83 348 x 115 x 83 1) In accordance with DIN EN 50083-3 at 60 db IMD (2nd order interference products) 2) In accordance with DIN EN 50083-3 at 60 db IMD (3rd order interference products) 3) In accordance with DIN EN 50083-3 at 35 db IMD (2nd order interference products) 4) In accordance with DIN EN 50083-3 at 35 db IMD (3rd order interference products)

Five cable system, cascadable for 4 or 8 subscribers per unit Type CMK 5405 CMK 5805 Order No. 947 619-002 947 641-002 S CMK 5405 S CMK 5805 S=switching command 13/18 V and 0/22 khz Frequency range MHz 47-862 950-2400 47-862 950-2400 Throughpass attenuation input St /output St db 2.5 1.5 4.0 2.5 Tap-off attenuation input St /output Re db 16 15 20 18 Decoupling - vert./hor. db - 25-25 - input St /output St db - 40-36 - 40-36 - input St /output Re db 30 15 30 18 Max. output level dbµv - 90 1) - 90 1) Switching voltage vert./hor. V 13/18 13/18 Switch. volt. low/high band khz 0/22 0/22 Current cons. per subscriber ma 110 100 Operating temp. (EN 60065) C 20 to +60 20 to +60 Weight kg 0.6 0.8 Dimensions W x H x D mm 235 x 115 x 70 235 x 115 x 70 1) In accordance with EN 50083 at 35 db IMD (3rd order interference products) St: Trunk, Re: Five cable system cascade example: S CS 348 C or Hit CS 400 Terr remote feed voltage Sat/Terr V H V H = CVE 55x0 ~ Sat/Terr S CMK 5405 For the distribution of 4 satellite IF signals and terrestrial signals to 4 or 8 subscribers in conjunction with feed-in amplifiers CVE 5510 or CVE 5520 Cascadable with further multiswitches CMK 5405 or CMK 5805 and the postamplifiers CNV 5510 or CNV 5520 For the reception of digital and analog signals The CMK is remotely fed with power via the receivers connected At each subscriber output it is possible to switch to one of the four satellite inputs using the switching command 13/18 V and 0/22 khz The terrestrial signals are also present with the receiver switched off Down leads after the feed-in amplifiers CVE 5510 or CVE 5520 are voltage free Metal housing with plastic side brackets for installation indoors Inputs and outputs: F-connectors, 75 Ohm Meets EN 50083-1 and -2 For high reliability of the digital electronics, all multiswitches in the five cable system are equipped with the high-tech ASIC chip CMK 5805 S S=switching command 13/18 V and 0/22 khz CNV 55x0 CMK 5405 = ~ Sat/Terr S Sat/Terr 5 x RFC 75 83

Multiswitches Nine cable system/diseqc (with terrestr. input) for 4, 6 and 8 subscribers Type CKR 9400 ND CKR 9600 ND CKR 9800 ND Order No. 947 648-001 947 649-001 947 650-001 Used as single unit, 9 inputs, for analog and digital signals For selecting one of eight satellite planes, for example from two different satellites, independent of any of the receivers connected. The following can be selected from both satellites: H/low band, H/high band, V/low band or V/high band Selection is made from the receiver over the RF cable using - switching voltage 13/18 V - 0/22 khz and - DiSEqC signal Completely DiSEqC compatible (DiSEqC 2.0). This means that the switching relay, e.g. - sends confirmation of the selection to the receiver - answers receiver inquiries as to the setting of the relay Separate input for feeding in terrestrial signals and permanent relay to all subscribers Connection of 4 subscribers with CKR 9400 ND 6 subscribers with CKR 9600 ND 8 subscribers with CKR 9800 ND Locally fed LNBs supplied from the multiswitch Metal housing with plastic side brackets for installation indoors RF connections with F-connectors Meets EN 50083-1, -2 Terr: 47-862 MHz Sat: 950-2300 MHz S: switching command 13/18 V 0/22 khz Terr Sat Sat/Terr S CKR 9400 ND 2 x CS 348 C or 2 x Hit CS 400 Fig.: CKR 9400 ND Frequency range MHz 47-862 950-2300 47-862 950-2300 47-862 950-2300 Throughpass attenuation db 16 6 18 6 18 6 Decoupling - input/input db > 40 > 40 > 40 > 40 > 40 > 30 - output/output db > 25 > 25 > 25 > 25 > 25 > 25 Switching command for DiSEqC signal or tone burst with 13/18 V and 0/22 khz selecting an input Operating voltage V 230 V ~ ± 10% 230 V ~ ± 10% Rem. feed current, 13 V max. ma 500 500 500 Rem. feed current, 18 V max. ma 1200 1200 1200 Operating temperature C 20 to +60 20 to +60 Dimensions W x H x D mm 400 x 80 x 115 400 x 80 x 115 400 x 80 x 115 Max. output level dbµv - 102 2) - 102 2) - 102 2) 1) In accordance with EN 50083-3 at 35 db IMD (3rd order interference products) = ~ Terr Sat Sat/Terr CKR 9600 ND 2 x CS 348 C or 2 x Hit CS 400 = ~ S Terr Sat Sat/Terr S CKR 9800 ND 2 x CS 348 C or 2 x Hit CS 400 = ~ 84

Nine cable system DiSEqC (with terrestr. input) for 12 and 16 subscribers Type CKR 9120 ND CKR 9160 ND Order No. 947 685-001 947 686-001 Terr: 47-862 MHz Sat: 950-2300 MHz S: switching command 13/18 V 0/22 khz CKR 9120 ND Frequency range MHz 47-862 950-2300 47-862 950-2300 Throughpass attenuation db 8 8 10 8 Decoupling - input/input db 40 40 40 40 - output/output db > 25 > 25 > 25 > 25 Switching command for DiSEqC signal or tone burst with 13/18 V and 0/22 khz selecting an input Operating voltage V 94-265 94-265 Rem. feed current, 13 V max. ma 500 500 Rem. feed current, 18 V max. ma 1200 1200 Operating temperature C 20 to +60 20 to +60 Dimensions W x H x D mm 400 x 80 x 205 400 x 80 x 205 Max. output level dbµv 79 1) 102 2) 79 1) 102 2) 1) In accordance with DIN EN 50083-3 at 60 db IMD (2nd order interference products) 2) In accordance with DIN EN 50083-3 at 35 db IMD (3rd order interference products) Terr Sat Sat/Terr S 8 2 x CS 348 C or 2 x Hit CS 400 = ~ Terr Sat Sat/ Terr S Fig.: CKR 9120 ND CKR 9160 ND 12 2 x CS 348 C or 2 x Hit CS 400 = ~ Used as single unit, 9 inputs, for analog and digital signals For selecting one of eight satellite planes, for example from two different satellites, independent of any of the receivers connected. The following can be selected from both satellites: H/low band, H/high band, V/low band or V/high band Selection is made from the receiver over the RF cable using - switching voltage13/18 V - 0/22 khz and - DiSEqC signal Completely DiSEqC compatible (DiSEqC 2.0). This means that the switching relay, e.g. - sends confirmation of the selection to the receiver - answers receiver inquiries as to the setting of the relay Switching signal 22 khz for universal LNB can be enabled Connection of 12 subscribers with CKR 9120 ND 16 subscribers with CKR 9160 ND Separate input for feeding in terrestrial signals and permanent relaying to all subscribers Level control 10 db for each input Locally fed LNBs supplied from the multiswitch Metal housing with plastic side brackets for installation indoors RF connections with F-connectors Meets EN 50083-2 85

Multiswitches Nine cable system with DiSEqC, cascadable, 9 inputs and outputs, 4-24 subscribers Feed-in multiswitch CVE 9409 ND Used as headend for the multiswitch nine cable system Separate input for feeding in terrestrial signals Locally fed Type CVE 9409 ND CMK 9409 D Order No. 981 000-366 981 000-363 Multiswitch CMK 9409 D Cascadable by relaying the trunk lines Remotely fed from the receiver connected, no additional power supply required A post-amplifier CNV 9009 ND is to be fitted after every second CMK 9409 D Fig.: CVE 9409 ND Common features For floor star distribution in systems with 4 to 24 subscribers, for analog and digital signals For selecting one of eight satellite planes, for example from two different satellites, independent of any of the receivers connected. The following can be selected from both satellites: H/low band, H/high band, V/low band or V/high band Selection is made from the receiver over the RF cable using - switching voltage 13/18 V - 0/22 khz and - DiSEqC signal Completely DiSEqC compatible (DiSEqC 2.0). This means that the switching relay, e.g. - sends confirmation of the selection to the receiver - answers receiver inquiries as to the setting of the relay Terrestrial signals are permanently relayed to all subscribers over a separate trunk line, even when the receivers are switched off Termination resistors for terminating the cascade are included with the feedin multiswitch CVE 9409 ND LNBs supplied from the multiswitch Metal housing with plastic side brackets for installation indoors RF connections with F-connectors Meets EN 50083-1, -2 Terr: 47-862 MHz Sat: 950-2300 MHz S: switching command 13/18 V 0/22 khz Terr Sat = ~ Sat/ Terr CVE 9409 ND CMK 9409 D e. g. 2 x CS 348 C Sat/ Terr S CMK 9409 D CMK 9409 D Frequency range MHz 47-862 950-2300 47-862 950-2300 Throu. atten. input St /output St db 3-4 1.0-2.5 3-4 1.0-2.5 Tap-off atten. input St /output Re db 15-18 12-8 15-18 12-8 Decoupling - input sat St /input sat St db > 25 > 25 > 25 > 25 - input terr St /input sat St db > 30 > 30 > 30 > 30 - input sat St /input terr St db > 35 > 35 > 35 > 35 - output St /output St db > 40 > 40 > 40 > 40 Switching command for DiSEqC signal or tone burst with 13/18 V and 0/22 khz selecting an input Operating voltage V 230 V ~ ± 10% - Rem. feed current, 13 V max. ma 350 - Rem. feed current, 18 V max. ma 850 - Operating temperature C 20 to +60 20 to +60 Dimensions W x H x D mm 330 x 115 x 65 355 x 115 x 65 St: Trunk, Re: = ~ Sat CVE 9409 ND Terr Sat/ Terr S 86

Nine cable system, post amplifier for 4-24 subscribers, cascadable Type CNV 9009 ND Order No. 981 000-364 Terr: 47-862 MHz Sat: 950-2300 MHz S: switching command 13/18 V 0/22 khz CMK 9409 D CMK 9409 D Frequency range MHZ 47-862 950-2300 Gain db 16-19 12-15 Max. output level dbµv 95 1) 108 2) Noise figure db 7 5 Decoupling input/input db > 40 >40 input/output db > 40 >40 output/output db > 40 >40 Oper. voltage/current consumption 230 V~ ±10% Operating temperature C 20 to + 60 Dimensions W x H x D mm 330 x 115 x 65 1) In accordance with DIN EN 50083 at 60 db IMD (3rd order interference products) 2) in accordance with DIN EN 50083 at 35 db IMD (3rd order interference products) = ~ Sat CNV 9009 ND Terr Sat/ Terr S Post-amplifier for compensating attenuation losses in the cascade. Amplifies satellite and terrestrial signals, analog and digital Cascadable with multiswitch CMK 9409 D Terrestrial signals are fed over a separate trunk line Each trunk line is individually amplified and distributed A post-amplifier CNV 9009 ND is to be fitted after every second CMK 9409 D Termination resistors for terminating the cascade are included with the feedin multiswitch CVE 9409 ND Locally fed Metal housing with plastic side brackets for installation indoors RF connections with F-connectors Meets EN 50083-2 87

Multiswitches Multiswitches example systems For 4, 6, 8, 12 and 16 subscribers 5 cable system/ 4 subscribers 5 cable system/ 6 subscribers 5 cable system/ 8 subscribers CS 348 C CS 348 C CS 348 C CKR 5041 CKR 5061 CKR 5081 5 cable system /12 subscribers 5 cable system /16 subscribers CS 348 C CS 348 C Single switches for multiswitch system analog / digital CKR 5121 CKR 5161 9 cable system /4 subscribers 9 cable system /6 subscribers 9 cable system /8 subscribers 2 x CS 348 2 x CS 348 2 x CS 348 CKR 9400 ND CKR 9600 ND CKR 9800 ND 88

Signal Processing SAT IF converter unit Compact headend CSE 100/102 Block converter Analog and digital satellite processing Modules for CSE 2000 Analog and digital satellite processing system CSE 3200 Modules for CSE 3200 TELECOP modulator 89

Signal Processing The single-cable solution for the future Using the compact headend station CSE 12, analog and digital programs from different satellites can be selected, individually converted, arranged in a new order as required - and that in the 1st SAT IF Unwanted programs can be filtered out Compact headend station CSE 12 Base unit Type CSE 12 Order No. 960 843-003 SAT IF to SAT IF, analog and digital In the output frequency range from 950 MHz to 2150 MHz, using 3 x CSE 12 up to 36 analog programs can be converted and several hundred digital programs received Problem-free distribution of programs from different satellites and different polarizations (e.g. ASTRA, Eutelsat, Türksat, Intelsat) All existing installation structures and networks can still to be used s with an upper frequency limit of 1750 MHz can still be used Remote feeding of receiving systems via inputs 1, 4, 7, 10 Channel-selective level control Constant output level due to AGC Optional data transfer cable for transmitting programming data to a further base unit CSE 12 Mains cable with Euro plug, approx. 1m Meets EN 50083-1, -2 Input frequency MHz 950-2150 Frequency steps MHz 1 Input level dbµv 52-75 IF bandwidth, switchable MHz 27 / 36 Oscillator interference at input db < 65 Output frequency MHz 950-2150 Output level (AGC stabilised) dbµv 70-85 Level control db 20 Loop-through input MHz 5-2150 Signal to oscillator level at output db > 25 Spurious signal level at output db > 30 LNB power supply 18 V/1 A/420 ma on outputs 1, 4, 7, 10 Connections inputs F-sockets outputs F-socket Operating voltage 230 V ~ ±10% / 50-60 Hz Power consumption W max. 66 Operating temperature C 0 to +50 Dimensions mm 380 x 240 x 90 Weight kg 3.8 Input distribution panel Type CEV 12 Order No. 960 844-001 Distributes the signals from one satellite or more to the 12 inputs of the base unit CSE 12 Plugs directly into F-type connectors Relays the remote feed voltage directly to the receiving systems Any required distribution variation can be implemented Meets EN 50083-1, -2 Input frequency MHz 950-2150 Connections inputs F-sockets outputs F-quick connectors Coupling off attenuation db 14-20, pre-equalized Switch isolation db min. 20 Current throughpass, max. 1.4 A / 24 V (4 x from output 1, 4, 7, 10) Operating temperature C 0 to +50 Dimensions mm 275 x 95 x 25 Weight kg 0.4 90

Band pass filters Type CBS 20 CBS 06 Order No. 960 847-001 960 848-001 Throughpass tap-off Throughpass range MHz 950-2150 950-2150 Throughpass attenuation db 2.5 2.5 Current pass-through, max. A 0.4 0.4 Filter tap-off Throughpass range MHz 1288-1906 1421-1612 Gain db 14 14 Output level (35 db IMA3) dbµv 105 105 Rejection range MHz 950-1245/ 950-1355/ MHz 1980-2150 1700-2150 Current consumption ma 80 80 Connections input F-socket F-socket outputs 1 x F-socket, 1 x F-socket, 1 x F-plug 1 x F-plug Dimensions mm 90 x 47 x 20 90 x 47 x 20 Weight kg 0.13 0.13 Band pass filters for CSE 12 The filters can be screwed on directly to the base unit CSE 12 and the input distribution panel CEV 12 without the need for additional parts No additional distribution units are required Remote feed voltage is relayed directly to the receiving system All band pass filters can be retrofitted or replaced at any time CBS 20 Filters out 20 programs from ASTRA 1 A, 1 B, 1 C horizontally These are passed to the CSE 12 via the IF input so that 32 programs can be received Included in the 32 programs are all important German stations as well as tm 3, arte, VIVA, and VIVA II CBS 06 Filters out 6 programs from ASTRA 1 A and 1 C vertically These are passed to the CSE 12 via the IF input so that 30 programs can be received All important German programs including DW-TV, VIVA, VIVA II, tm 3 and EURO NEWS, as well as RAI UNO, RAI DUE, BBC World, NBC, CNN etc. can be received via ASTRA and Eutelsat 91

Signal Processing Satellite signal processing with perfectly matched high-tech components Satellite signal processing unit for small SMATV (e.g. block of flats and residential estates) Low cost alternative to satellite reception with receivers Both for new installations and as an expansion for existing installations TV and video equipment can be operated independently in a flat Compact headend station CSE 100 Mono, CSE 102 Stereo Base units Type CSE 100 CSE 100-5 CSE 102 Order No. 960 784-002 960 784-003 960 805-001 Quick installation easy programming Problem-free and quick installation Five programs are already preprogrammed Programs set can be changed at any time Channel spacing or frequency spacing can be programmed as required Programming set available as kit from Hirschmann Service Center, Order No. 496 750-200 Hirschmann quality Made in Germany Developed and manufactured in proven Hirschmann quality Satellite signal processing, analog Mono version (CSE 100) or stereo version (CSE 102) with a package of five programs CSE 100-5 also with 5 decoder interfaces Can be expanded to cover up to 20 programs through the use of several units With the block converter CBC 103, up to 30 programs are then possible Video polarity switching for C band satellites (only CSE 100) Can be set to the standards PAL G, I, K and SECAM L, (CSE 102 stereo can be set to TV standard PAL G) Decoder connection for the reception of encrypted programs RF connections F-sockets Meets EN 50083-1, -2 92 Input frequency MHz 950-2050 Input level dbµv 47-70 2nd IF MHz 480 IF bandwidth MHz 15 / 27 27 Frequency tuning PLL synthesizer, AFC can be switched off FM threshold (static) 7 db C/N TV standards G/L/I/K (M prepared) G Output channel range C 22 to C 69 tuneable (8 MHz spacing) Output frequency range MHz 478-862 (250 khz steps) Output level dbµv 100, adjustable 0-10 db Throughpass input F-socket (47-862 MHz) Throughpass attenuation db 3.5 Video signal (clamped, filtered) Bandwidth video MHz 5 baseband MHz 10 De-emphasis CCIR recommendation 405-1 (625 lines) or linear, by internal jumpers Video deviation compens., switchable 13.5/16/19/22.5 MHz per Volt Energy dispersion suppression db > 30 Decoder connections 2 5 2 Output/ video V pp 1 input level baseband V pp 1 audio mv 500 Outputs/inputs Submin D sockets, 15-pole, 3-row Audio audio carrier frequencies 5.5-9.5 MHz (10 steps) de-emphasis Adaptive de-emphasis for mono and stereo on main audio carrier 50 µs or J 17 50 µs bandwidths 150 khz for sub audio carrier 350 khz for main audio carrier operating modes Mono/stereo summation/main audio carrier frequency range 40 Hz-15 khz cumulative harmonic distortion factor < 1% LNB supply +18 V, max. 500 ma Mains voltage 230 V~ ±10% / 50-60 Hz max. 55 W Mains cable approx. 2 m with Euro plug, meets IEC 65 Operating temperature C 10 to +50 Dimensions mm 380 x 250 x 90 Weight kg 3

Input distribution panel Type CEV 100 Order No. 960 802-001 1st polarization plane H/V Frequency range MHz 950-1750 1750-2150 Throughpass attenuation db 1.7 2.2 Connection attenuation db 13.5 13.5 Directional attenuation db 25 25 Internal decoupling db 18 18 2nd polarization plane V/H Frequency range MHz 950-1750 1750-2150 Throughpass attenuation db 3.6 4.4 Connection attenuation db 13 13 Directional attenuation db 25 25 Internal decoupling db 28 20 Max. rem. feeding curr. per input ma 500 Operating temperature C 20 to +60 Specially for CSE 100 and CSE 102 Stereo For distributing the signals from one or more satellites to the five inputs on a CSE 100 or CSE 102 Can be plugged in directly (using F-quick-connectors) Relaying of the remote feed voltage to the receiving systems Any required distribution variation can be implemented RF-connections input: F-sockets, output: F-quick connectors 75 Ω termination resistor (RFC 75) and a connecting cable included Meets EN 50 083-1,-2 Block converter Type CBC 103 Order No. 960 818-001 Conversion Feed-through Input frequency range MHz 475-625 47-862 Output frequency range MHz 160-310 - Gain db 4 3 Signal to noise ratio (S/N) db 69 - Max. output level dbµv 92 1) Power consumption W approx. 3 Operating voltage 230 V ~ + 6%, 10% / 50-60 Hz Ambient temperature C 10 to +50 Dimensions mm 125 x 105 x 83 Weight kg 0.35 1) For 60 db IMA (CSO, CTB) and channel load with 10 TV channels 10 additional programs through conversion from UHF to VHF For placing on the output of the CSE 100 / CSE 102 Stereo All systems with CSE 100 / CSE 102 Stereo can be retrofitted at any time Conversion to band III and special channels S9-S21 Feed-through capability for the frequency range from 47-862 MHz RF connections F-sockets Meets EN 50 083-1,-2 93

Signal Processing CSE 2000 - the new headend station generation from Hirschmann Ever more attractive analog and increasingly also digital programs require new, innovative headend station systems. Using the new CSE 2000, Hirschmann is offering a flexible, modular system in which analog and digital processing units complement each other ideally. The new headend system from Hirschmann for adjacent channel operation is used for the reception and processing of analog and digital satellite programs, ADR signals, as well as terrestrial TV and FM programs The system consists of the base unit with 8 slots for modules. Integrated into the base unit is a programmable input distribution panel with six inputs and 16 outputs. An integrated control unit allows easy programing of all modules Multi-standard modules for international TV standards Additional audio/video modulators for injecting external signals into the system It is possible to remove a module from the base unit or change the slot without reprogramming the module Attenuator on each module allows the balancing of the output level Decoder interfaces for the connection of decoders / descramblers for signal decryption The system can use adjacent channels without restrictions Remotely controlable The integrated output amplifier is designed to feed large networks Installation in 19" rack or wall mounting possible 94

Headend station CSE 2000 Base unit Type CSE 2000 Order No. 960 900-001 Input frequency MHz 950-2400 Input level dbµv 60-85 Output frequency MHz 47-862 Output level analog 1) dbµv max. 104 digital dbµv max. 100 Attenuation loop-through input db 4 Input distribution panel Inputs 6 Outputs 16 Throughpass attenuation db 12 Decoupling input / input db 25 Output amplifier Gain db 28 Output level dbµv 108 Frequency response db 3 Noise factor db 6.5 Level control db 0-20 Base unit CSE 2000 For the installation of up to 8 modules (single or twin) Sturdy, screened metal housing with - control unit - 7-segment display - programmable satellite input distribution panel - output amplifier - power supply Housing can be locked Serial interface for service and PC programming Passive loop-through input For indoor installation on the wall or in a 19" rack Power supply Operating voltage 160-265 V~, 50-60 Hz 88-140 V~, 50-60 Hz internally switchable Power consumption W approx. 120, fully equipped with 8 modules incl. remote feed Remote feed voltage V 0 / 13 / 18, switchable Remote feed current via inputs 1, 3, 5, 6 4 x 500 ma, in total max. 1 A RF connections F-sockets Serial interface 4-pole RJ 45 socket Operating temperature C 0 to +50 Dimensions W x H x D mm 484 x 358 x 221 Weight kg 8.8 (14 kg fully equipped with CHS 2000 S) 1) According to EN 50 083-3, channel load with 16 TV channels at 60 db IMA (2nd order interference products) 95

Signal Processing CHD 2000 M / S For processing QPSK modulated SAT IF signals into an analog output channel (PAL) Search functions Selection of TV programs or radio programs without picture (black screen) Audio processing in accordance with standards 9-pole submin D socket for PC connection, for upgrading the module software All RF connections F-sockets Common interface module CHI 2000 for decoding encrypted signals can be added as an option Test picture generator Audio level adjustable CHD 2000 Q For processing QPSK modulated SAT IF signals into a QAM modulated output channel Normal or inverted position can be set Generator for pseudo-random signals and unmodulated carrier for calibrating the system Quality diagnostics of the input signal All connections F-sockets Headend station CSE 2000 Satellite TV modules, digital Type CHD 2000 S CHD 2000 M CHD 2000 Q Order No. 960 902-101 960 907-101 960 897-101 Programs converted 1 1 1 transponder Processing QPSK > PAL QPSK > PAL QPSK > QAM Input frequency range MHz 920-2150 920-2150 950-2150 AFC MHz ±4 ±4 ±8 Input level dbµv 47-70 47-70 47-70 Symbol rate MS/s 2-35 2-35 15.0-29.999 1) Output symbol rate, max MS/s - - 7 Output level dbµv 90 90 87 Output frequency range MHz 110-862 110-862 110-862 TV standard B/G D/K, L, I - Modulation - - 16, 64 QAM 1) 1) Other values on request Satellite TV modules, analog Type CHS 2000 S CHS 2000 B CHS 2000 M CHS 2000 O Order No. 960 899-101 960 910-101 960 898-101 960 909-101 For processing analog satellite TV signals into a TV channel in the terrestrial band TWIN modules (except CHS 2000 B) 3-step adjustable FM threshold Integrated baseband interface can be used by adding an optional interface CHE 2000 D AFC ±8 db Level control 0-20 db F-sockets for output and loop-through input Test picture generator Audio level can be adjusted 96 Channels converted 2 1 2 2 Input frequency range MHz 950-2150 Input level dbµv 47-70 Video deviation selectable MHz 16/22.5 Video polarity - neg./pos. neg./pos. - Video bandwidth 20 Hz-5 MHz Audio frequency MHz 5.5-9.5 Audio IF bandwidth khz 150 / 350 Audio de-emphasis adaptive / 50 µs Output frequency range MHz 110-862 45-470 110-862 110-862 Output level dbµv 90 TV standard B/G (stereo) D/K, I, L D/K, I, L D/K (OIRT)

TV modules, analog, terrestrial Type CHT 2000 T CHT 2000 B CHT 2000 M Order No. 960 903-101 960 911-101 960 973-101 Channels converted 2 1 2 Input frequency range MHz 47-862 45-862 45-862 Input level dbµv 70-85 Audio signal Stereo Stereo, Nicam Stereo, Nicam Output frequency range MHz 110-862 45-470 110-862 Output level dbµv 90 Attenuator db 0-20 TV standard B/G D/K, I, L D/K, I, L Channel converter, for converting channels within the terrestrial band TWIN modules (except CHT 2000 B) Automatic gain control (AGC) All connections F-sockets Audio/video modulator modules Type CHM 2000 S CHM 2000 M Order No. 960 912-101 960 913-101 Channels 2 2 Video input level V pp 1 Video bandwidth 20 Hz-5 MHz Audio signal Stereo, dual, mono Mono Audio input level mvms 500, R i = 10 kω Audio bandwidth 40 Hz-15 khz Output frequency range MHz 110-862 Output level dbµv 90 Attenuator db 0-20 TV standard B/G D/K, I, L TWIN modules Modulation audio/video to TV Interface CHE 2000 D for the injection of audio and video signals is included Submin D sockets for audio / video inputs F-sockets for output and loop-through input 97

Signal Processing ADR processing module CHA 2000 A Processing of 2 subcarriers - ADR (QPSK modulated) or - analog (SAT subcarrier pairs) into FM signals Station identification information contained in the ADR signal is modulated on the FM signal as an RDS signal in accordance with the standards Via the optional interface CHE 2000 D, up to 2 audio signals can be injected, modulated and converted to the FM band Entry of RDS station names via the control panel for analog signals FM converter CHA 2000 U Conversion of two FM programs in the frequency range 87.5 MHz-108 MHz to any two FM frequencies Same channel operation possible Very high neighboring channel separation Automatic gain control (AGC) FM amplifier CHV 2000 U For amplifying the FM band Six tunable traps for attenuating local stations with high signal levels Two traps can be used for the same input frequency to increase the attenuation Headend station CSE 2000 FM processing module Type CHA 2000 A CHA 2000 U CHV 2000 U Order No. 960 905-101 960 906-101 960 904-101 Function Processing FM converter FM amplifier (ADR or analog) 2 FM channels into into 2 FM channels 2 FM channels Input frequency range MHz 950-2150 87.5-108 87.5-108 Input level dbµv 47-70 53-99 Analog subcarrier MHz 6-9 - - ADR subcarrier MHz 0.18-9 - - Gain db - - 34 Noise factor db - - 3 Reduction per trap db - - 14 Output frequency range MHz 87.5-108 87.5-108 87.5-108 Output level dbµv 91 91 91 Attenuator db 0-20 Interface CHE 2000 D For fitting to analog modules For the connection of decoder/descrambler for signal decryption For feeding video and audio signals into the system Forced switching via 12 V switching voltage possible A 15-pole submin D socket per channel with inputs and outputs for video and audio signals Interface CHI 2000 I For plugging onto digital satellite modules CHD 2000 S and CHD 2000 M For decoding encrypted signals Defined common interface port for a CA module with smart card from all major providers: VIACCESS, NAGRAVISION, CONAX, CRYTOWORKS, IRDETO Interfaces Type CHE 2000 D CHI 2000 I Order No. 960 901-101 960 972-001 Function with module type analog digital Interface for the following modules CHA 2000 A CHD 200 S CHS 2000 S CHD 2000 M CHS 2000 M CHS 2000 O CHS 2000 B 98

Accessories for headend station CSE 2000 Programming kit Type CHZ 2000 P Order No. 960 914-001 Programming kit For connecting to the serial interface on the base unit or a PC The programming kit adopts - the settings of all modules fitted to a base unit - settings that have been made on the PC These settings can then be transferred from the programming kit to the modules in a second base unit No need to set up existing module configurations again A programming kit can copy and store the settings from up to 4 base units (= a 19" rack) For operation on the PC, the programming software CHZ 2000 S and an external power supply (6-18 V), e.g. CST 18/600, are necessary Programming Software Type CHZ 2000 S Order No. 960 915-001 Programming software Facilitates the convenient configuration of a base unit CSE 2000, all module settings can be made directly on the PC Several configurations can, e.g., be preprogrammed and stored ready for use The configuration can be transferred directly to a base unit CSE 2000 connected directly to the PC or to the programming kit CHZ 2000 P connected to the PC The connecting cable is included, an RS 232 interface is required on the PC Runs under Windows Facilitates the remote control of the headend station via modem 99

Signal Processing Headend station system CSE 3200 Processing of analog and digital satellite TV programs as well as satellite audio subcarriers and ADR programs Converting of terrestrial TV and radio signals Amplifying of radio signals Base unit CSS 3012 A For fitting up to 12 modules with the capability of processing up to 24 TV or 48 radio programs Base unit CSS 3016 For fitting up to 16 modules with the capability of processing up to 32 TV or 64 radio programs Base unit CSS 3042 For fitting up to 2 double or single modules with the capability of processing up to 4 TV or 8 radio programs. Expansion unit for the base units CSS 3012 A and CSS 3016 The connection to the active bus panel is established when a module is inserted in a free slot. All signals for the indoor distribution system are available at the bus panel s output Adjacent channels can be used without restriction Each module has a level control for balancing the output signals The modules are menu programmed via the integrated control unit For servicing modules can be replaced without the need for reprogramming, except for CKU 3220 A Voltage for the bus panel and the feed voltage for the receiving systems can be drawn from the front of the power supply unit Upward compatibility: all modules of the previously used CSR 3100 system can also be used in the base unit CSS 3012 A (not in CSS 3016) Downward compatibility: all modules can be used in the CSR 3100 system and fit also into the older base unit CSS 3002 A Base unit CSS 3012 A 100

Headend station system CSE 3200 Base units Type CSS 3042 CSS 3012 A CSS 3016 Order No. 960 890-001 960 962-001 948 403-001 Fig.: CSS 3012 A with door removed Fig.: CSS3016 with door removed Slots for modules 2 12 16 Input frequency range MHz 950-2150 Output frequency range MHz 45-862 Input distribution panel Number of inputs 2 4 4 Outputs (per input) - 9 9 Input level see modules (47-80 dbµv) Throughpass attenuation db - 16 16 RF connections F-sockets F-sockets F-sockets Output amplifier Frequency range MHz 45-862 45-862 45-862 Output level 1), max. dbµv 94-107, 106 104 depending on module - - Adjustable attenuator db 20 20 20 Outputs F-sockets IEC sockets IEC sockets Power supply Operating voltage V~ 220-240, 50-60 Hz 195-260, 50-60 Hz 195-260, 50-60 Hz Power consumption, approx. W 48, fully equipped 180, fully equipped 190, fully equipped incl. remote feeding incl. remote feeding incl. remote feeding of the LNB s of the LNB s of the LNB s Remote feed for LNBs 14 V/0.5 A 18 V/1 A, 18 V/1 A, short-circuit proof short-circuit proof Operating temperature C 20 to +50 20 to +50 20 to +50 Dimensions W x H x D mm 412 x 395 x 110 700 x 410 x 310 532 x 637 x 310 Weight, fully equipped kg approx. 8 approx. 50 approx. 60 1) Measured fully equipped and with max. number of TV channels: all interference products (CSO,CTB, CMX) reduced by 60 db CSS 3042 For fitting up to 2 double or single modules Expansion for the base units - CSS 3016 (CSE 3200 system) - CSS 3012 A (CSE 3200 system) - CSS 3002 A (CSE 3100 system) Consists of a sturdy, screened metal housing with - central microprocessor control unit, - RF bus panel and - power supply Meets EN 50083-1, -2, EN 60065 CSS 3012 A: for fitting up to 12 modules for max. 24 TV or 48 radio programs CSS 3016: for fitting up to 16 new modules only, for max. 32 TV or 64 radio programs CSS 3012 A + CSS 3016 Consists of a sturdy, screened metal housing with - central microprocessor control unit, - input distribution panel, - output amplifier and - power supply Microprocessor control unit: - dialog-driven via display - connected to the individual modules via I 2 C bus rails Satellite input distribution panel: - 4 inputs - 9 outputs per input The connection to the modules is made by using pre-assembled coaxial cables which are included with the modules The integrated hybrid amplifier permits an adjustable output level of up to 106 dbµv Installation indoors The unit can either be placed on a flat surface or mounted on the wall with the enclosed hardware Doors can be locked and removed from their hinges for servicing Meets EN 50083-1, -2, EN 60065 101

Signal Processing Satellite TV modules, digital, single Type CDQ 3935 CDQ 3940 CDP 3930 CDP 3940 Digital TV modules, QPSK QAM For processing QPSK modulated SAT IF signals into a QAM modulated output channel The module has a satellite input, an RF output as well as a digital input and output (parallel MPEG II interface) Coaxial cable for the connection to the input distribution panel included Digital TV modules, QPSK PAL For processing QPSK-modulated SAT IF signals into an analog output channel (PAL) S-VHS interface (modified) with signal inputs/outputs: 1 x composite video, 2 x audio, 12 V switching voltage Coaxial cable for the connection to the input distribution panel included Order No. 960 893-002 948 402-001 960 894-002 948 399-001 Conversion QPSK QAM QAM PAL PAL Input frequency range MHz 950-2150 Input level dbµv 35-80 Symbol rate MS/s 3-30 (MCPC/SCPC) Modulation 4, 16, 32, 64, 128, 256 QAM - - Output frequency range MHz 302-462 470-862 118-382 470-862 Standard - - B/G, CCIR G, CCIR Interface RS 232 - - Data rate 19.2 kbit decoder, retrofittable - - 15-pole submin D socket MPEG II 25-pole submin D, parallel - - S-VHS (modified) - - Operating temperature C 5 to +50 Satellite TV modules, analog, twin, CCIR Type CKM 3913 CKM 3933 CKM 3955 CKM 3944 Order No. 948 384-001 948 385-001 948 387-001 948 386-001 For processing two FM modulated satellite TV signals from the 1st IF position into VHF/UHF standard channels (CCIR) Adjacent channel operation possible Using the control unit the following can be set: input and output channels with fine tuning, video deviation, IF bandwidth, audio frequency, operating mode, de-emphasis, volume Coaxial cable for the connection to the input distribution panel included Decoder retrofit set CDN 3800 S Conversion Channel A: 1st SAT IF K 2-K 4 S 3-S 24 S 21-S 41 K 21-K 69 Channel B: 1st SAT IF S 3-S 24 S 3-S 24 S 21-S 41 K 21-K 69 Input frequency range MHz 950-2150 Input level dbµv 57-80 Output frequency range channel A: MHz 47-68, 118-334 302-462 470-862 channel B: MHz 118-334 118-334 302-462 470-862 Standard B/G B/G G G Operating temperature C 5 to +50 102

Headend station system CSE 3200 Terrestrial TV modules, analog, twin, CCIR Type CKU 3013 CKU 3033 CKU 3055 CKU 3044 Order No. 948 392-001 948 393-001 948 395-001 948 394-001 Conversion channel A: 47-862 MHz MHz 47-68 119-334 302-470 470-862 channel B: 47-862 MHz MHz 119-334 119-334 302-470 470-862 Input level dbµv 75-85 Standard B/G Operating temperature C 5 to +50 For converting two standard CCIR TV channels from the bands I, III or IV/V into two standard CCIR TV channels in the bands VHF I, LSC, VHF III, USC and UHF IV/V Input and output channels can be fine tuned using the control unit Adjacent channel operation possible FM processing modules Type CKS 3922 CKU 3224 CVU 3200 Order No. 948 391-002 960 895-002 960 696-003 Function Processing FM converter FM amplifier (ADR or analog) 4 FM channels into into 2 FM channels 4 FM channels Input frequency range MHz 950-2150 87.5-108 87.5-108 Input level dbµv 47-70 10-95 10-95 Gain db - - 43 Noise factor db < 9 Reduction per trap db - - 14-17 Output frequency range MHz 87.5-108 Operating temperature C 5 to +50 ADR processing CKS 3922 For processing 2 ADR carriers or analog satellite carrier pairs from the SAT IF plane or from an external baseband source into the FM band, with RDS modulation Inputs, either 1st IF or 15-pole submin D socket, can be used together or individually for channel processing Audio input/output (stereo) Baseband input/output Coaxial cable for the connection to the input distribution panel included FM converter CKU 3224 For converting 4 FM channels into four other FM channels Adjacent channel operation possible Programmable via the control unit in the base unit FM amplifier CVU 3200 For amplifying the FM band Six adjustable traps for attenuating local stations with high signal levels Level control for adjusting to high receiving voltages 103

Signal Processing Satellite TV modules, digital, single, OIRT Type CDP 3930 O CDP 3940 O Order No. 960 400-001 948 401-002 Digital TV modules QPSK PAL For processing a QPSK modulated SAT IF signal into an analog output channel (PAL, OIRT) Coaxial cable for the connection to the input distribution panel included Decoder retrofit set CDN 3800 S Conversion QPSK PAL, OIRT Input frequency range MHz 950-2150 Input level dbµv 35-80 Symbol rate MS/s 3-30 (MCPC/SCPC) Output frequency range MHz 118-334 470-862 Standard D/K (OIRT) Interface RS 232 9-pole submin D socket, serial S-VHS (modified) Operating temperature C 5 to +50 Satellite TV modules, analog, twin, OIRT Type CKM 3913 O CKM 3933 O CKM 3944 O Order No. 948 388-001 948 389-001 948 390-001 For processing two FM modulated satellite TV signals from the 1st IF position into VHF/UHF standard channels (OIRT) Adjacent channel operation possible Using the control unit the following can be set: input and output channels with fine tuning, video deviation, IF bandwidth, audio frequency, audio main/sub carrier, main carrier de-emphasis, volume adjustment Coaxial cable for the connection to the input distribution panel included Decoder retrofit set CDN 3800 S Conversion Channel A: 1st SAT IF MHz 48.5-230 118-334 470-862 Channel B: 1st SAT IF MHz 118-334 118-334 470-862 Input frequency range MHz 950-2150 Input level dbµv 57-80 Standard D/K (OIRT) D/K (OIRT) K (OIRT) Operating temperature C 5 to +50 104

Headend station system CSE 3200 Terrestrial TV modules, analog, twin, OIRT Type CKU 3013 O CKU 3033 O CKU 3044 O Order No. 948 396-001 948 397-001 948 398-001 Conversion Channel A: 47-862 MHz MHz 48-95 118-334 470-862 Channel B: 47-862 MHz MHz 118-334 118-334 470-862 Input level dbµv 72-84 75-85 72-84 Output frequency range MHz 48-328 119-328 470-862 Standard OIRT OIRT OIRT Operating temperature C 5 to +50 For converting two standard OIRT TV channels from the bands I, II (OIRT), III or IV/ V into two standard OIRT TV channels in the bands VHF I, VHF III and UHF IV/V Input and output channels can be fine tuned using the control unit Adjacent channel operation possible Decoder retrofit kit Type CDN 3800 S Order No. 960 750-001 Connections 15-pole high density submin D socket, matching plug included Submin D socket assignments 1/6 = Audio input left/right 2 = Composite video input 3 = External switching voltage 0/12 V 4 = Baseband output (unclamped, PAL de-emphasis) 5 1 10 6 5 = Comp. video output (clamped, PAL de-emphasis) 15 11 8/11 = Ground 9 = + 12 V 12/13 = Audio output left/right For connecting of - decoder/descrambler, - video recorder for feeding in video programs - external audio/video sources, e.g. surveillance camera for children s playground For retrofitting the SAT TV modules CKM Provides one satellite channel as clamped composite video signal and as a baseband signal. If required, this can be switched from PAL de-emphasis to flat de-emphasis (no de-emphasis) Suitable for feeding in video and audio signals 105

Signal Processing TELECOP modulator Type TELECOP Modulator Order No. 960 856-001 Modulates a video/audio signal and transfers it to a UHF TV channel For the connection of a video camera, e.g. for monitoring: - the house entrance - the children s play area - the garden gate or garage door Audio signal can be fed in via microphone The modulated signal is fed into the existing house distribution network and provides an additional TV program to each subscriber The modulator provides the operating voltage for the video camera Suitable for all common television standards e.g. standards G, I, K, L, M Built-in test picture generator Meets EN 50083-1,-2 Accessories For increasing the output level, an amplifier, e.g. GHV 20 or GHV 30 can be connected after the modulator Video input Frequency range MHz 0-5 Connection DIN 5-pin MAB 5100S Impedance Ω 75 Level V pp 1 S/N weighted db 50 Audio input Connection DIN 5-pin MAB 5100S Impedance kω 5 Level V pp 1.23 RF output Frequency range MHz 470-862, 1 channel from K 21-K 69, adjust. Connection F-connector, socket Impedance Ω 75 Level dbµv 71 Modulation / video signal Double side band Spurious signal level up to 862 MHz db 60 TV standard G, I, K, L, M, adjustable Camera voltage/current 12 V / max. 400 ma Operating voltage 230 V~ + 6%, <10% / 50-60 Hz Power consumption, approx. W 18 Operating temperature C 10 to +50 1) Weight kg 2.5 1) In accordance with EN 60 065, functionality is retained in the range of 20 C to +60 C 106

Tap-offs, Distribution Boxes, Couplers Overview of tap-offs/distribution boxes Tap-offs/distribution boxes with screw terminals Tap-offs/distribution boxes in semi-circular housing Tap-offs/distribution boxes for broadband cable with F-connections Tap-offs/distribution boxes for satellite with F-connections Second unit distribution box Antenna couplers Remote feed voltage coupler 107

Tap-offs, Distr. Box., Couplers Overview Primary area of use single/matv with satellite () CATV indoor distribution Frequency range AM (0.15 4 MHz) CATV (5-862 MHz) Terr. + SAT (5-2400 MHz) return path possible Connections screw terminals F-connectors Installation surface mounting flush mounting Remote feed possible Tap-offs 1 x ARS 0912 A ARS 101 AFC 0811 AFC 1011 S ARS 1412 A AFC 1211 AFC 1511 S ARS 2012 A AFC 1611 AFC 2011 S AFC 2011 AFC 2511 S 2 x ARS 1024 A ARS 102 AFC 0921 AFC 1021 S ARS 1424 A AFC 1221 AFC 1521 S ARS 2024 A AFC 1621 AFC 2021 S AFC 2021 AFC 2521 S 3 x ARS 1034 A ARS 1434 A ARS 2034 A 4 x AFC 1041 S AFC 1641 AFC 1541 S AFC 2041 S AFC 2541 S 6 x AFC 1861 8 x AFC 2081 Distribution 2 x VEDO 0422 A VEDO 042 VFC 0421 VFC 0421 SF Boxes VEDO 0422 F 3 x VEDO 0632 A VEDO 063 F VFC 0631 VFC 0631 SF 4 x VEDO 0744 A VFC 0741 VFC 0741 SF 6 x VFC 061 8 x VFC 1281 12 x VFC 1219 not shown 108

Introduction Tap-offs For the connection of one or more tap-off cables to a continuous (trunk) cable. Trunk input Tap-off Throughpass attenuation Attenuation between trunk input and trunk output. Trunk input Tap-off 1 Coupling attenuation Attenuation between the tap-offs (in the case of multiple tap-offs). Tap-off 2 Trunk output Trunk output Trunk input Trunk output Tap-off Tap-off attenuation Attenuation between the trunk input and the tap-off (in the case of tap-off without directional couplers, also between the trunk output and the tapoff). Trunk input Trunk output Tap-off Directional attenuation Attenuation between the trunk output and the tapoff (in the case of tapoffs with directional couplers). Distribution boxes For splitting an incoming trunk cable s signals into two or more trunk cables. Trunk input Distribution attenuation Attenuation between trunk input and trunk outputs. Trunk output Trunk output Trunk input Coupling attenuation Attenuation between the outputs. Trunk output Trunk output 109

Tap-offs, Distr. Box., Couplers Tap-offs with screw terminals in rectangular housing 1 x Type ARS 0912 A ARS 1412 A ARS 2012 A Order No. 947 472-002 947 473-002 947 474-002 1 x Tap-offs Die-cast housing with screw cover Universal for all distributions in cabinets and indoors Surface mounted Suitable for return path For cable with inner conductor Ø: max. 1.5 mm outer conductor Ø: min. 4.0 mm max. 9.0 mm Meets EN 50083-1, -2, -4 Frequency range MHz Throughpass db 0.15-30 1.4 1.2 1 attenuation 47-862 1.2-1.4 0.8 0.6 950-2400 2.0-2.4 1.2-1.6 1.0-1.4 Tap-off db 0.15-30 11.5 15 20 attenuation 47-862 10 15 20 950-2400 10 14.5 20-21 Directional db 0.15-30 16-22 15-30 22-30 attenuation 47-862 34-32 36-32 36-32 950-2400 20-18 24-22 26 Dimensions L x W x H mm 96 x 52 x 30.2 96 x 52 x 30.2 96 x 52 x 30.2 2 x Type ARS 1024 A ARS 1424 A ARS 2024 A Order No. 947 475-002 947 476-002 947 477-002 2 x Tap-offs Die-cast housing with screw cover Universal for all distributions in cabinets and indoors Surface mounted Suitable for return path For cable with inner conductor Ø: max. 1.5 mm outer conductor Ø: min. 4.0 mm max. 9.0 mm Meets EN 50083-1, -2, -4 110 Frequency range MHz Throughpass db 0.15-30 2.8 2.4 1.6 attenuation 47-862 2.5 1.6 1.2 950-2400 4.0-4.8 2.4-3.2 2.0-2.8 Tap-off db 0.15-30 11.5 15 20 attenuation 1 47-862 10 15 20 950-2400 10 15 20-21 Tap-off db 0.15-30 12.5 16.5 20.5 attenuation 2 47-862 11.5 15.5 20.5 950-2400 11.5-12.5 15.5 20.5 Coupling db 0.15-30 26-32 30-40 40-50 attenuation 47-862 44-42 46 50 950-2400 30-28 36 40 Directional db 0.15-30 16-22 15-26 22-30 attenuation 47-862 34-32 36-32 36-32 950-2400 20-18 24-22 26 Dimensions L x W x H mm 141 x 52 x 30.2 141 x 52 x 30.2 141 x 52 x 30.2

Tap-offs with screw terminals in rectangular housing 3 x Type ARS 1034 A ARS 1434 A ARS 2034 A Order No. 947 478-002 947 479-002 947 480-002 Frequency range MHz Throughpass db 0.15-30 4.4 4.6 2.4 attenuation 47-862 4 2.4 1.8 950-2400 5.8-7.2 3.6-4.8 3.0-4.2 Tap-off db 0.15-30 11.5 15 20 attenuation 1 47-862 10 15 20 950-2400 10 15 20 Tap-off db 0.15-30 12.5 16.5 20 attenuation 2 47-862 11.5 15.5 20 950-2400 12 16 20 Tap-off db 0.15-30 13.5 18 21 attenuation 3 47-862 13 16.5 21 950-2400 13.5 16.5 21 Coupling db 0.15-30 26-32 30-40 40-50 attenuation 47-862 44-42 46 50 950-2400 30-28 36 40 Directional db 0.15-30 16-22 15-26 22-30 attenuation 47-862 34-32 36-32 36 950-2400 20-18 24-22 26 Dimensions L x W x H mm 141 x 52 x 30.2 141 x 52 x 30.2 141 x 52 x 30.2 3 x Tap-offs Die-cast housing with screw cover Universal for all distributions in cabinets and indoors Surface mounted Suitable for return path For cable with inner conductor Ø: max. 1.5 mm outer conductor Ø: min. 4.0 mm max. 9.0 mm Meets EN 50083-1, -2, -4 111

Tap-offs, Distr. Box., Couplers Distribution boxes with screw terminals in rectangular housing 2 x Type VEDO 0422 A VEDO 0422 F Order No. 947 469-002 947 511-002 2 x Distribution boxes Die-cast housing with screw cover Universal for all distributions in cabinets and indoors Surface mounted For cable with inner conductor Ø: max. 1.5 mm outer conductor Ø: min. 4.0 mm max. 9.0 mm Meets EN 50083-1, -2, -4 VEDO 0422 F: remote feed of both outputs to the input (diode decoupling) Frequencyrange MHz Distribution db 0.15-30 6 - attenuation 47-862 3.8-4.2 3.8-4.2 950-2400 5-6 5.2-6.2 Coupling db 0.15-30 4-20 - attenuation 47-862 24-20 24-20 950-2400 20-18 20-18 Max. rem. feed volt./current per output - 24 V=/500 ma Dimensions L x W x H mm 96 x 52 x 30.2 96 x 52 x 30.2 3 x, 4 x Type VEDO 0632 A VEDO 0744 A Order No. 947 470-002 947 471-002 3, 4 x Distribution boxes Die-cast housing with screw cover Universal for all distributions in cabinets and indoors Surface mounted For cable with inner conductor Ø: max. 1.5 mm outer conductor Ø: min. 4.0 mm max. 9.0 mm Meets EN 50083-1, -2, -4 Frequency range MHz Distribution db 0.15-30 7 8.5 attenuation 47-862 7.0-7.5 8.5-9.2 950-2400 8.5-9.5 10-11 Coupling db 0.15-30 6-22 4-17 attenuation 47-862 22-18 18-16 950-2400 18 16 Dimensions L x W x H mm 141 x 52 x 30.2 141 x 52 x 30.2 112

Tap-offs with screw terminals in semi-circular housing 1 x, 2 x Type ARS 101 ARS 102 Order No. 945 020-001 945 021-001 Frequency range MHz DC DC Throughpass db 4-30 1.4 2.8 attenuation 47-862 1.2-1.4 2.4-2.6 950-2400 2.0-2.4 4.0-4.8 Tap-off db 4-30 10 11.5 attenuation 1 47-862 10 10 950-2400 10 10.5 Tap-off db 4-30 - 125 attenuation 2 47-862 - 11.5 950-2400 - 12.5 Coupling db 4-30 - 32 attenuation 47-862 - 42-44 950-2400 - 28-30 Directional db 4-30 22 22 attenuation 47-862 34-32 34-32 950-2400 20-18 20-18 Dimensions ø mm 53.5 (26 high) 53.5 (26 high) 1, 2 x Tap-offs Die-cast housing with integrated hinged clamps Hinged clamps can be fixed in place Universal for all indoor distributions Surface mounted or installed in a Ø 70 mm flush mounting box (with mini or midi cable also in55, =^ 58 mm Ø, flush mounting box), screws for surface mounting included Suitable for return path For cable with inner conductor Ø: 0.4-1.4 mm outer conductor Ø: 2.7-5.7 mm Remote feed possible via trunk input/output, max. 500 ma/24 V DC Meets EN 50083-1, -2, -4 Distribution boxes with screw terminals in semi-circular housing 2 x, 3 x Type VEDO 042 VEDO 063 F Order No. 945 022-001 945 023-001 Frequency range MHz DC DC Distribution db 0.15-30 5 7 attenuation 47-862 3.8-4.2 7.0-7.7 950-2400 4.8-5.8 8.5-9.5 Coupling db 0.15-30 20 22 attenuation 47-862 24-20 22-18 950-2400 20-18 18 Dimensions ø mm 53.5 (26 high) 53.5 (26 high) 2, 3 x distribution boxes Die-cast housing with integrated hinged clamps Hinged clamps can be fixed in place Universal for all indoor distributions Surface mounted or installed in a Ø 70 mm flush mounting box (with mini or midi cable also in55, =^ 58 mm Ø, flush mounting box), screws for surface mounting included Suitable for return path For cable with inner conductor Ø: 0.4-1.4 mm outer conductor Ø: 2.7-5.7 mm VEDO 042: remote feed possible via input and outputs, max. 500 ma/24 V VEDO 063 F: remote feed possible via input/output 1, max. 500 ma/24 V Meets EN 50083-1, -2, -4 113

Tap-offs, Distr. Box., Couplers Tap-offs with F-connections, frequency range up to 1000 MHz 1 x Type AFC 0811 AFC 1211 AFC 1611 AFC 2011 Order No 947 359-101 947 360-101 947 361-101 947 362-101 1 x Tap-off Die-cast housing For CATV indoor distribution Surface mounted For F-connections with inner conductor Ø: min. 0.5 mm max. 1.2 mm Suitable for return path Inner conductor isolated capacitively Meets EN 50083-1, -2, -4 Frequency range MHz Throughpass db 5-40 1.5 0.8 0.5 0.5 attenuation 40-1000 1.5-2.0 0.8-1.1 0.5-0.7 0.5-0.7 Tap-off db 5-40 8.5 12 16 20 attenuation 40-1000 8.5 12 16 20 Directional db 5-40 30 24 36 38 attenuation 40-1000 30 1) 32 1) 36 40 1) Dimensions L x W x H mm 24x50x51 24x50x51 24x50x51 24x50x51 1) From 40 MHz, reduced by 1.5 db per octave 2 x Type AFC 0921 AFC 1221 AFC 1621 AFC 2021 Order No. 947 363-101 947 364-101 947 365-101 947 366-101 2 x Tap-off Die-cast housing For CATV indoor distribution Surface mounted For F-connections with inner conductor Ø: min. 0.5 mm max. 1.2 mm Suitable for return path Inner conductor isolated capacitively Meets EN 50083-1, -2, -4 Frequency range MHz Throughpass db 5-40 3.7 1.5 0.8 0.8 attenuation 40-1000 2.8-3.5 1.5-1.9 1.1-1.5 1.1-1.5 Tap-off db 5-40 8.5 13 16.5 20 attenuation 40-1000 8.5 13 16.5 20 Coupling db 5-40 28 40 46 50 attenuation 40-1000 28-22 40-32 46-36 50-36 Directional db 5-40 18 28 34 36 attenuation 40-1000 20-18 30 1) 34 1) 36 1) Dimensions L x W x H mm 24x72x51 24x72x51 24x72x51 24x72x51 1) From 40 MHz, reduced by 1.5 db per octave 114

Tap-off with F-connections, frequency range up to 1000 MHz 4 x, 6 x, 8 x, 12 x Type AFC 1641 AFC 1861 AFC 2081 VFC 1219 Order No. 947 367-101 947 368-101 947 369-101 947 585-001 Fig.: AFC 1641 Fig.: VFC 1219 Frequency range MHz Throughpass db 5-40 4.5 6 9 - attenuation 40-862 3.8-4.0 6 8 - Tap-off db 5-40 12.5 12.5 12.5 11.5 attenuation 1 40-1000 12.5 12.5 12.5 11.5 Tap-off db 5-40 13.5 13.5 13.5 13 attenuation 2 40-1000 13.5 13.5 13.5 13 Tap-off db 5-40 14.5 14.5 14.5 15 attenuation 3 40-1000 14.5 14.5 14.5 15-16 Tap-off db 5-40 15 15.5 15 15 attenuation 4 40-1000 15 15.5 15 15-16 Tap-off db 5-40 - 16.5 16 16.3 attenuation 5 40-1000 - 16.5 16 17 Tap-off db 5-40 - 17.5 17 16.3 attenuation 6 40-1000 - 17.5 17 17 Tap-off db 5-40 - - 18 17.5 attenuation 7 40-1000 - - 18 18 Tap-off db 5-40 - - 19 17.5 attenuation 8 40-1000 - - 19 18 Tap-off db 5-40 - - - 18 attenuation 9+10 40-1000 - - - 18 Tap-off db 5-40 - - - 19 attenuation 11+12 40-1000 - - - 19 Coupling db 5-40 38 40 36 36 attenuation 40-1000 40-34 40-36 40-36 36-34 Directional db 5-40 26 26 26 - attenuation 40-1000 30-25 30-24 30-24 - Dimensions L x W x H mm 91x60x 40 135x60x 40 135x60x 40 179x52x 40 4, 6, 8, 12 x Tap-offs Die-cast housing For CATV indoor distribution Surface mounted For F-connections with inner conductor Ø: min. 0.5 mm max. 1.2 mm Suitable for return path Inner conductor isolated capacitively Meets EN 50083-1, -2, -4 VFC 1219: Shielding rate up to 300 MHz > 85 db 470 MHz > 80 db 1000 MHz > 75 db Meets EN 50083 Part 1/A1, Part 2/A1, Part 4 115

Tap-offs, Distr. Box., Couplers Distribution boxes with F-connections, frequency range up to 1000 MHz 2 x, 3 x, 4 x Type VFC 0421 VFC 0631 VFC 0741 Order No. 947 355-101 947 356-101 947 357-101 Fig.: VFC 0421 2, 3, 4 x Distribution boxes Die-cast housing For CATV indoor distribution For F-connections with inner conductor Ø: min. 0.5 mm max.1.2 mm Suitable for return path Inner conductor isolated capacitively Surface mounted Meets EN 50083-1, -2, -4 Frequency range MHz Distribution db 5-40 3.5 3.5 7.2 attenuation 1 40-1000 3.9-4.4 3.8-4.4 7.5-8.2 Distribution db 5-40 3.5 6.8 7.2 attenuation 2 40-1000 3.9-4.4 7.0-8.2 7.5-8.2 Distribution db 5-40 - 6.8 7.2 attenuation 3 40-1000 - 7.0-8.2 7.5-8.2 Distribution db 5-40 - - 7.2 attenuation 4 40-1000 - - 7.5-8.2 Coupling db 5-40 24 20 22 attenuation 40-1000 25-20 25-22 24-20 Dimensions L x W x H mm 50 x 51 x 24 72 x 51 x 24 72 x 51 x 24 6 x, 8 x Type VFC 1061 VFC 1281 Order No. 981 000-108 981 000-109 Fig.: VFC 1281 6, 8 x Distribution boxes Die-cast housing For CATV indoor distribution For F-connections with inner conductor Ø: min. 0.5 mm max.1.2 mm Test output 20 db Suitable for return path Inner conductor isolated capacitively Surface mounted Meets EN 50083-1, -2, -4 Frequencyrange MHz Distribution db 5-40 10.7 12.3 attenuation 1+2 40-1000 10.7-12.0 12.3-13.2 Distribution db 5-40 10.7 12.3 attenuation 3+4 40-1000 10.7-12.0 12.3-13.2 Distribution db 5-40 10.7 12.3 attenuation 5+6 40-1000 10.7-12.0 12.3-13.2 Distribution db 5-40 - 12.3 attenuation 7+8 40-1000 - 12.3-13.2 Coupling db 5-40 12 14 attenuation 40-1000 20 20 Dimensions L x W x H mm 135 x 60 x 41 135 x 60 x 41 116

Tap-offs with F-connections, frequency range up to 2400 MHz 1 x Type AFC 1011 S AFC 1511 S AFC 2011 S AFC 2511 S Order No. 947 564-002 947 565-002 947 658-002 947 659-002 Example assembly Frequency range MHz DC DC DC DC Throughpass db 5-40 2 1.5 1.5 1.5 attenuation 40-1000 2.5 1.5 1.5 1.5 1000-2400 3.2 2.2 2.2 2.2 Tap-off db 5-40 11 15 20 25 attenuation 40-1000 10 15 20 25 1000-2400 10 15 20 25 Directional db 5-40 26 30 35 40 attenuation 40-1000 22 25 30 30 1000-2400 20-18 22-20 25 28-25 Dimensions L x W x H mm 53 x 53 x 16 53 x 53 x 16 53 x 53 x 16 53 x 53 x 16 1 x Tap-offs With the spacer included two tap-offs can be fitted together For 1st SAT IF distribution in buildings Remote feed via trunk, DC max 24 V/1 A Die-cast housing Meets EN 50083-1, -2 2 x Type AFC 1021 S AFC 1521 S AFC 2021 S AFC 2521 S Order No. 947 566-002 947 567-002 947 622-002 947 660-002 Example assembly Frequency range MHz DC DC DC DC Throughpass db 5-40 4.5 3 2 1.5 attenuation 40-1000 3.5 3 2 1.5 1000-2400 4.5 4 3 2.5 Tap-off db 5-40 11 15 20 25 attenuation 40-1000 11 15 20 25 1000-2400 11 15 20 25 Coupling db 5-40 35 40 45 20 attenuation 40-1000 25 35 35 20 1000-2400 25-20 30-25 30 20 Directional db 5-40 18 23 25 30 attenuation 40-1000 18 20 22 25 1000-2400 17 20 22 25 Dimensions L x W x H mm 75 x 53 x 16 75 x 53 x 16 75 x 53 x 16 75 x 53 x 16 2 x Tap-offs With the spacer included two tap-offs can be fitted together For 1st SAT IF distribution in buildings Remote feed via trunk, DC max 24 V/1 A Die-cast housing Meets EN 50083-1, -2 117

Tap-offs, Distr. Box., Couplers Tap-offs with F-connections, frequency range up to 2400 MHz 4 x Type AFC 1041 S AFC 1541 S AFC 2041 S AFC 2541 S Order No. 947 602-002 947 603-002 947 604-002 947 661-002 Example assembly 4 x Tap-offs With the spacer included two tap-offs can be fitted together For 1st SAT IF distribution in buildings Remote feed via trunk, DC max 24 V/1 A Die-cast housing Meets EN 50083-1, -2 Frequency range MHz DC DC DC DC Throughpass db 5-40 5 3 1.5 1.5 attenuation 40-1000 6 3.5 2 1.5 1000-2400 6 5 3 2.5 Tap-off db 5-40 10.5 15 20 25 attenuation 40-1000 11.5 15 20 25 1000-2400 13 15.5 20.5 25.5 Coupling db 5-40 18 20 20 20 attenuation 40-1000 20 22 22 22 1000-2400 18 20 20 20 Directional db 5-40 20 30 40 45 attenuation 40-1000 23 23 25 30 1000-2400 20-18 20 20 25 Dimensions L x W x H mm 75 x 62 x 16 75 x 62 x 16 75 x 62 x 16 75 x 62 x 16 Distribution boxes with F-connections, frequency range up to 2400 MHz 2, 3, 4 x Type VFC 0421 SF VFC 0631 SF VFC 0741 SF Order No. 947 568-002 947 569-002 947 570-002 2, 3, 4 x Distribution boxes With the spacer included two distribution boxes can be fitted together For 1st SAT IF distribution in buildings Die-cast housing Surface mounted For F-connections with inner conductor Ø: min. 0.5 mm max. 1.2 mm Suitable for remote feed via all outlets Remote feed 24 V DC/1A Meets EN 50083-1, -2, -4 Frequency range MHz Example assembly DC DC DC Distribution db 5-40 4.5 7.5 8.5 attenuation 40-1000 5 8 9 1000-2400 6.2 10.5 11 Coupling db 5-40 18 20 22 attenuation 40-1000 20 20 20 1000-2400 20 20 20 Dimensions L x B x H mm 53 x 53 x 16 53 x 53 x 16 53 x 53 x 16 118

Plug-on distribution box for device output Type VZV 420 F Order No. 981 000-020 Frequency range MHz Distribution db 0.15-26.1 3.5 attenuation 47-862 3.5 950-2050 5 Coupling db 0.15-26.1 3.5 attenuation 47-862 20 950-2050 14 Dimensions L x W x H mm 45 x 48 x 20 Can be plugged onto devices with IEC sockets Remote feed voltage is passed through over both branches Diode decoupled outputs RF connections with coaxial sockets and plugs in accordance with IEC 169-2 Meets EN 50083-2 Second unit distribution box, passive, active Type ZGV 77 ZVA 134 Order No. 947 502-001 947 440-002 Frequency range MHz Distribution db 0.15-862 3.5 - attenuation 950-2150 5 - Coupling db 0.15-862 18 - attenuation 950-2150 15 - Gain per output db 47-862 - 6 Max. perm. output level dbµv 47-862 - 100 1), 80 2) Coupling attenuation db 47-862 - 16 Noise figure db 47-862 - 6 Operating voltage - 230V~ +6%, 10%/50-60Hz Operating temperature C 20 to +50 For connecting two TV sets to one antenna outlet socket Can be plugged into the TV output of antenna outlet sockets conforming to IEC 169-2 Distribution to two radio sets is also possible when using the KVS 1 coaxial connector (see Connectors section) ZVA 134: with built-in amplifier. Separate plug-type power supply unit, cable approx. 1.5 m long Meets EN 50083-1, -2 1) For 60 db IMD (3rd order interference products) according to EN 45 004 B and channel load of 2 channels. If more than 2 channels are assigned, the output level must be reduced in the usual manner. 2) For 60 db IMD (2nd order interference products) according to EN 45 004 A1. The maximum operating level permitted is the lesser of 1) and 2)! 119

Tap-offs, Distr. Box., Couplers Antenna couplers for outdoor mounting Multi-band couplers for outdoor mounting 0.15-862 MHz Type Hit AWN 60 B 3/4 Order No. 945 036-000 Weather-proof, black plastic housing with brackets for masts up to 50 mm Ø or for fixing to the wall with two screws For combining or separating two or more frequency ranges Coaxial inputs and outputs RF cable connection with screw terminals and cable clamp Only for export outside the EU Frequency range AM FM VHF I VHF III UHF IV/V MHz 0.15-26.1 87.5-108 47-68 174-230 470-862 Throughpass attenuation db 1 1 2 Dimensions mm 107 x 65 x 47 Multi-band couplers for outdoor mounting 0.5-862 MHz Type WAK 301 Order No. 945 004-000 Weather-proof, black plastic housing with brackets for masts up to 50 mm Ø or for fixing to the wall with two screws For combining or separating two or more frequency ranges Coaxial inputs and outputs RF cable connection with screw terminal and cable clamp Only for export outside the EU Frequency range AM FM VHF I VHF III UHF IV/V MHz 0.15-26.1 87.5-108 47-68 174-230 470-862 Throughpass attenuation db 1 1 1 2 Dimensions mm 135 x 90 x 60 Antenna couplers for indoor mounting Band coupler for 0.15-446 MHz and 470-862 MHz Type BWS 202 Order No. 947 338-001 470-862 MHz 2 1 0,15-446 MHz 120 For combining or separating two frequency ranges RF connections with coaxial sockets and plugs in accordance with IEC 169-2 Mounting bracket for wall mounting included Meets EN 50 083-1, -2 0,15-862 MHz Freq. range MHz 0.15-446 470-862 Throughp. att. db 0.5 0.5 Suppr. atten. db 24 24 Dimensions mm 70 x 90 x 35

Antenna couplers for indoor mounting Band coupler for 47-862 MHz and 950-2400 MHz Type BWS 2910 F Order No. 981 000-041 Frequency range input 1 satellite MHz 950-2050 input 2 terr. MHz 47 862 Throughpass attenuation satellite input db 1.5 terr. input db 1.0 Remote feed input 1 Remote feed current max. 1A Dimensions mm 67 x 71 x 24 For combining or separating terrestrial signals and satellite IF signals All connections are F-connectors Meets EN 50 083-1, -2 Band coupler for 47-862 MHz and 950-2400 MHz Type BWS 3910 F Order No. 981 000-042 Frequency range 1 terr. input MHz 47-862 2 satellite inputs MHz 950-2400 2 outputs MHz 47-2400 Throughpass attenuation, terr. db 4.5 Throughpass attenuation, sat. db 2 Remote feed both satellite inputs Remote feed current per branch max. 1 A Dimensions mm 100 x 95 x 32 For combining terrestrial signals and satellite IF signals for 2 subscribers All connections are F-connectors 121

Tap-offs, Distr. Box., Couplers Band couplers Band couplers for 47-862 MHz and 950-2200 MHz Type BWS 4910 F Order No. 981 000-552 For combining terrestrial signals and satellite IF signals for 4 subscribers For use with Hit CS 404 and CS 358 C Quatro-Switch LNB All connections are F-connectors To provide active terrestrial operation even if the receiver is switched off, it is necessary to connect a commercially available plug-type power unit with a 3.5 mm jack. In passive operation, terrestrial transmission is also possible without a power supply Frequency range 1 terr. input MHz 47-862 4 satellite inputs MHz 950-2200 4 outputs MHz 47-2200 Throughpass attenuation, terr. db 12-14 (passive), 4-6 (active) Throughpass attenuation, sat. db 4-6 Remote feed 4 satellite inputs Remote feed current per branch 500mA DC for active operation 12-18 V/100 ma (socket for 3.5 mm jack) Current consumption, active terr. approx. 40 ma Dimensions mm 120 x 85 x 40 Remote feed voltage coupler Type FW 2 Order No. 947 442-001 For combining or separating RF and the remote feed voltage Suitable for return path Can be plugged onto all device inputs with RF sockets conforming with IEC 169-2 Supply voltage fed in through attached switch circuit Meets 50083-1, -2a Frequency range MHz 5-2050 Maximal load carrying capacity 60 Veff/540 maeff Throughpass attenuation db 0.8-2.0 Dimensions mm 51 x 36 x 22 122

Antenna Outlet Sockets Overview of antenna outlet sockets Super broadband sockets standard range Special satellite sockets Data sockets Special types Filter sockets connecting cable Termination resistance Distance frame, cover plate central plates 123

Antenna Outlet Sockets Introduction Attenuation Trunk input Throughpass attenuation Attenuation between trunk input and trunk output. Plug Trunk input Socket Internal coupling attenuation Attenuation between plug output and socket output. Trunk output Trunk output Plug Trunk input Trunk output Socket Connection attenuation Attenuation between trunk input and plug or socket output. Plug Trunk input Socket EN coupling attenuation (2 outlet method) Attenuation between the outputs of two antenna outlet sockets. Plug Socket Trunk output Socket types Double antenna outlet sockets Universal sockets, suitable for satellite, terrestrial and broadband cable, CATV Triple antenna outlet sockets For individual satellite and SMATV installations Data socket for broadband cable/catv 4 x antenna outlet sockets For use in multiswitch installations (star or tree structure) TV Network structures RF TV Satellite RF Data Floor star Star network Tree network Tree and star network H V H V 6 x GEVU 15 Switch 124

Overview Standard range Characteristics RP VHF I FM VHF/UHF Sat Super broadband Universality, Universal for all 4 sockets for all applications applications Future-oriented assignment of the outputs EDU 04 F EDU 04 F remote feed GEDU 10/15/20 via TV plug Spec. satellite sockets Indiv. sat. and SMATV inst. with 1st sat. IF distribution EDA 3902 F Single cable connection GEDA 3913 F with selec. distribution, remote feed via sat. output EVU 02 F Two separate connections with selective distribution remote feed via both sat. outputs GEVU 15 Switch Two separate connections with integrated multiswitches, switchable via both sat. outputs RF (IEC) TV RF (IEC) TV S 1 (F) RF (IEC) TV S 1 (F) S 2 RF (IEC) TV S 1 (F) S 2 Data sockets FSE 6502 FSD 6510 FSD 6513 FSD 6515 Single cable connection with selective distribution with extremely high decoupling of the data output RF (IEC) TV Data (F) Special types Specially configured subscriber connections for CATV networks FS 1 D FS 7 D FS 12 D FS 1 NL FS 1 B Minimum attenuation for optimized star distribution Selective filter sockets Selective filter sockets with galvanic isolation RF (IEC) TV RF (IEC) TV ED 01 S GD 11 S Remote feed via satellite socket Sat (IEC) RF/TV 125

Antenna Outlet Sockets Double Antenna outlet sockets Super broadband technology: future-orientated up to 2400 MHz Universal socket suitable for connecting a radio, TV set or satellite receiver Suitable for satellite, terrestrial and broadband cable, CATV Can be used for all international standards: B/G, D/K, I, L, M, CCIR/OIRT, PAL/SECAM/NTSC/digital TV Continuous cross over area at both outputs, i.e. any assignment with both return path and forward path possible Easy installation and connection Socket and plug to IEC 169-2 Can be installed in 55 flush mounting box (58 mm Ø) or in distance frame Please order termination resistor, frame, and cover plate separately Shielding rate EMC class A up to 300 MHz > 85 db 470 MHz > 80 db 1000 MHz > 75 db 2400 MHz > 55 db Quantity boxed: 10 pieces GEDU 10, 15 and 20 meet EN 50083-1/ A1, -2 EDU 04 F meets EN 50083-1/ A1, -2/A1 Standard range super broadband Single socket Type EDU 04 F Order No. 947 527-001 Throughpass socket Type GEDU 10 Order No. 947 529-001 Throughpass socket For use in individual and MATV installations on decoupled tap-off lines. Transmits remote feed voltage. Color code black max. 24 V 500 ma 2 1 2 1 For use in MATV installations preferably at the end of a trunk line with a large number of sockets. Color code blue Type GEDU 15 Order No. 947 528-001 For use in MATV installations. Colour code green 2 1 Throughpass socket Type GEDU 20 Order No. 947 530-001 For use in MATV installations preferably at the begin of a trunk line with a large number of outlet sockets. Color code red 2 1 126

RP VHF I FM LSC- UHF IV/V Sat IF VHF III ESC Frequency range MHz 5-40 47-68 87.5-108 125-470 470-862 950-2050 2050-2400 Connection attenuation 1 (RF), socket db 4.0 4.0 4.0 4.0 4.0 4.7 5.5 2 (TV), plug db 4.0 4.0 4.0 4.0 4.0 4.7 5.5 Internal coupling attenuation db 14 20 20 20 20 20 20 Remote feed voltage/current max. 24 V=/500 ma via TV output Frequency range MHz 5-40 47-68 87.5-108 125-470 470-862 950-2050 2050-2400 Throughpass attenuation db 2.8 2.2 2.2 2.2 2.4 3.2 4.2 Connection attenuation 1 (RF), socket db 11.5 10.0 10.0 10.0 10.0 10.0 11.5 2 (TV), plug db 11.5 10.0 10.0 10.0 10.0 10.0 11.5 Coupling attenuation RF/TV int. db 40 42 42 42 38 32 30 TV/TV db 40 50 50 50 46 32 32 Directional attenuation TV/RF db 35 40 40 40 36 22 20 Frequency range MHz 5-40 47-68 87.5-108 125-470 470-862 950-2050 2050-2400 Throughpass attenuation db 1.0 0.8 0.8 0.8 0.8 1.4 1.8 Connection attenuation 1 (RF), socket db 14.5 14.5 14.5 14.5 14.5 15.0 15.5 2 (TV), plug db 14.5 14.5 14.5 14.5 14.5 15.0 15.5 Coupling attenuation RF/TV int. db 18 24 24 24 24 24 24 TV/TV db 44 54 54 54 54 44 42 Directional attenuation TV/RF db 30 40 40 40 40 30 26 Frequency range MHz 5-40 47-68 87.5-108 125-470 470-862 950-2050 2050-2400 Throughpass attenuation db 0.8 0.6 0.6 0.6 0.8 1.1 1.4 Connection attenuation 1 (RF), socket db 20 20 20 20 20 20 21 2 (TV), plug db 20 20 20 20 20 20 20 Coupling attenuation RF/TV int. db 18 24 24 24 24 24 24 TV/TV db 60 64 64 64 60 50 50 Directional attenuation TV/RF db 40 44 44 44 40 30 30 127

Antenna Outlet Sockets Triple Antenna outlet sockets EDA 3902 F, GEDA 3913 F Suitable for satellite and terrestrial For satellite distribution in a tree structure For connecting a radio, TV and satellite receiver Outputs: socket for RF, plug for TV both to IEC 169-2, F-socket for satellite Connecting system for screw-less inner conductor clamping 0.8-1.3 mm Ø Can be installed in 55 flush mounting box (58 mm Ø) or in distance frame AR 20 50 x 50 mm central plate ADE 30 included Suitable for the majority of switch ranges Please order distance frame AR 20 and cover plate ADR 20 separately Quantity boxed: 4 pieces Meets EN 50083-1, -2 4 x Antenna Outlet Sockets EVU 02 F: For connecting a radio, TV and two independent connections for satellite receivers Two independent satellite receivers can be operated in conjunction with an external multiswitch GEVU 15 S: Two equivalent IEC outputs (socket and plug) for the connection of radios and TVs. Two outputs (F-sockets) each with an integrated H/V switch (multiswitch) to operate two satellite receivers independently EVU 02 F and GEVU 15 switch: Can be installed in 55 flush mounting box (58 mm Ø) or in distance frame 76 x 76 mm cover plate included Please order distance frame AR 20 separately Clamp connection: inner conductor: 0.4-1.4 mm Ø outer conductor: 2.7-4.5 mm Ø For connecting mini coaxial cable or KOKA 780 TWIN-Sat cable Quantity boxed: 10 pieces Meets EN 50083-1, -2 Standard program, special satellite sockets Single socket Type EDA 3902 F Order No. 947 499-301 Throughpass socket Type For use in individual and SMATV installations on decoupled tap-off lines. Transmits remote feed voltage via satellite output GEDA 3913 F Order No. 947 521-301 Single socket Type For use in SMATV installations. Remote feed voltage transmission via satellite outlet. Capacitively isolated termination resistor already fitted. EVU 02 F Order No. 947 282-001 Throughpass socket with integrated multiswitch Type TV TV Sat/terr. 1 max. 24 V / 500 ma Sat RF Sat RF max. 24 V 500 ma max. 24 V 500 ma Sat/terr. 2 max. 24 V / 500 ma Simultaneous connection of up to four sets possible. Throughpass of the remote feed TV FM voltage. For use in SMATV installations with multiswitches, extends broadband cable systems by including additional satellite programs. GEVU 15 S Order No. 947 281-001 Sat 1 H / V Sat 2 H / V Simultaneous connection of up to four sets possible. Integrated multiswitch for TV FM each satellite output (switched via 13 V (vertical) or 18 V (horiz.). For use in SMATV installations without additional multiswitches (two cable installation). H V 128

RP VHF I FM LSC-VHFIII UHF IV/V Sat IF ESC Frequency range MHz 5-40 47-68 87.5-108 174-470 470-862 950-2150 Connection attenuation RF, socket db 2.0 2.0 2.0 - - - TV, plug db 1.5 1.5 1.5 1.5 1.5 - Sat, F-socket db - - - - - 2.0-3.0 Remote feed voltage/current max. 24 V=/500 ma via satellite output Frequency range MHz 5-40 47-68 87.5-108 174-470 470-862 950-2150 Throughpass attenuation db 1.0 1.0 1.0 1.0 1.0 2.0-3.0 Connection attenuation RF, socket db 14 14 14 - - - TV, plug db 14 14 14 14 14 - Sat, F-socket db - - - - - 14 Coupling attenuation TV/TV db 45 45 45 45 45 - Terr./Sat db 20 20 20 20 20 20 Sat/Sat db - - - - - 32 Remote feed voltage/current max. 24 V=/500 ma via satellite output Frequency range MHz 5-40 47-68 87.5-108 125-470 470-862 950-2150 Connection attenuation input Ht/output FM (socket) db - - 6.5 - - - input Ht/output TV (plug) db 5.0 6.0-6.0 6.0 - input Ht/output S1 (F-socket) db 2.5 2.2 2.2 2.2 2.2 2.5 input V/output S2 (F-socket) db 0.2 0.4 0.4 0.4 0.4 0.5 Internal coupling attenuation Output S1/S2 db - - - 48 48 36-30 Remote feed voltage/current max. 24 V=/500 ma via satellite output Frequency range MHz 5-40 47-68 87.5-108 125-470 470-862 950-2150 Throughpass attenuation db 1 1 1 1 1.2 1.6-2.2 Connection attenuation inputv/output FM (socket) db 14 14 14 14 14 - input H/outputTV (socket) db 14 14 14 14 14 - S1/inputV or inputh (F-socket) db - - - - - 16 S2/inputV or inputh (F-socket) db - - - - - 16 Coupling attenuation input H/output S1 and V/S2 db - - - - - 36 input H/output S2 and V/S1 db - - - - - 36 Coupl. atten. int. output S1/S2 db - - - - - 26 Max. current cons. on S1 and S2 (max. 20 V) 30 ma 129

Antenna Outlet Sockets Data sockets Triple Antenna outlet sockets For connecting a radio, TV and a PC Suitable for broadband CATV installations Electrical isolation of the outputs FM/TV 1000 V AC (1 min.) Data 1500 V AC (1 min.) High decoupling of the data/tv/fm outputs Connecting system for screw-less inner conductor clamping 0.8-1.3 mm Ø Can be installed in 55 flush mounting box (58 mm Ø) or in distance frame 50 x 50 mm central plate included (standard spacing) Suitable for the majority of switch ranges Please order distance frame AR 20 and cover plate ADR 20 with central plates separately Quantity boxed: 4 pieces Meets EN 50083-1, -2 Single socket Type FSE 6502 Order No. 947 687-001 For use in individual and MATV installations on decoupled tap-off lines. Throughpass socket Type FSD 6510 Order No. 947 688-001 For use in broadband CATV installations on the end of a trunk line. TV TV Data RF Data RF Throughpass socket Type FSD 6513 Order No. 947 689-001 Data For use in broadband CATV installations. TV RF Throughpass socket Type FSD 6515 Order No. 947 690-001 Data For use in broadband CATV installations preferably at the start of a trunk line with a large number of sockets. TV RF 130

RP VHF I FM LSC-VHF III UHF IV/V ESC Frequency range MHz 5-40 47-65 86-108 125-470 470-862 Connection attenuation RF, socket db - - 4.0 - - TV, plug db - - - 2.0 2.0 data output, F-socket db 10 10 10 10 10 Coupling attenuation data/tv db 50 50-25 25 Frequency range MHz 5-30 47-68 87.5-108 125-470 470-862 Throughpass attenuation db 3.0 3.0 3.0 3.0 3.0 Connection attenuation RF, socket db - - 15 - - TV, plug db - 11-11 11 data output, F-socket db 10 10 10 10 10 Coupling attenuation TV/TV db 40 40 40 40 40 data/tv db 55 35 35 35 35 Frequency range MHz 5-30 47-68 87.5-108 125-470 470-862 Throughpass attenuation db 2.0 2.0 2.0 2.0 2.0 Connection attenuation RF, socket db - - 17 - - TV, plug db - 13-13 13 data output, F-socket db 12 12 12 12 12 Coupling attenuation TV/TV db 43 43 43 43 43 data/tv db 60 40 40 40 40 Frequency range MHz 5-30 47-68 87.5-108 125-470 470-862 Throughpass attenuation db 2.0 2.0 2.0 2.0 2.0 Connection attenuation RF, socket db - - 19.0 - - TV, plug db - 17.0-17.0 17.0 data output, F-socket db 15.5 15.5 15.5 15.5 15.5 Coupling attenuation TV/TV db 47 47 47 47 47 data/tv db 60 40 40 40 40 131

Antenna Outlet Sockets Double Antenna outlet sockets Filter sockets up to 1000 MHz Suitable for specially configured subscriber connections for broadband cable/catv networks For connecting a radio and a TV Suitable for return path (RP) Easy installation and connection Socket and plug to IEC 169-2 Can be installed in 55 flush mounting box (58 mm Ø) or in distance frame Please order accessories separately Special types in large quantities only Meets EN 50083-1, -2 Special types Single socket Type FS 1 D Order No. 947 593-001 Special socket for broadband CATV and MATV installations on decoupled tap-off lines. Throughpass socket Type FS 7 D Order No. 947 623-001 2 1 Special socket for broadband CATV and MATV installations. 2 1 Throughpass socket Type FS 12 D Order No. 947 594-001 Special socket for broadband CATV and MATV installations. 2 1 Single socket Type FS 1 NL Order No. 947 595-001 Special socket for broadband CATV and MATV installations on decoupled tap-off lines. Galvanic separation of the RF and TV coaxial connections (> 2 kv, 50 Hz). 2 1 Single socket Type FS 1 B Order No. 947 632-001 Special socket for broadband CATV and MATV installations on decoupled tap-off lines. Galvanic separation of the RF and TV coaxial connections (> 2 kv, 50 Hz). 2 1 132

RP/VHF I FM (LSC)-VHF III ESC UHF IV/V Frequency range MHz 5-68 87.5-108 118-125 125-470 470-1000 Connection attenuation 1 (RF), socket db 20 1.0 20 26 26 2 (TV), plug db 0.8 12 2.0 0.8 0.8 Internal coupling attenuation db 20 12 20 26 26 Frequency range MHz 5-68 87.5-108 118-125 125-470 470-1000 Throughpass attenuation db 2.8 2.8 2.8 2.8 3.3 Connection attenuation 1 (RF), socket db 30 8-26 30-26 2 (TV), plug db 7.4 18 8 7 8 Directional attenuation db 25 42 42 36 36 Internal coupling attenuation db 20 15-20 25-22 Frequency range MHz 5-68 87.5-108 118-125 125-470 470-1000 Throughpass attenuation db 0.8 0.8 0.8 0.8 0.8 Connection attenuation 1 (RF), socket db 30 12 30 36 36 2 (TV), plug db 12 22 12 11 11 Directional attenuation db 30 40 40 40 36 Internal coupling attenuation db 20 12 20 26 26 Frequency range MHz 5-75 87.5-140 160-174 174-470 470-862 Connection attenuation 1 (RF), socket db 33-12 1.3 12-17 17-36 26 2 (TV), plug db 1 12-14 1.5 0.8 0.8 Internal coupling attenuation db 33-12 12-14 12-17 17-36 26 Frequency attenuation MHz 5-75 87.5-108 118-125 125-470 470-862 Connection attenuation 1 (RF), socket db 30-12 1.8 12-14 14-26 26 2 (TV), plug db 1.8 12 1.8 0.8 0.8 Internal coupling attenuation db 30-12 12 12-14 14-26 26 133

Antenna Outlet Sockets Double Antenna outlet sockets Filter sockets up to 2400 MHz Universal socket for connecting a radio, TV or satellite receiver Suitable for satellite and terrestrial Suitable for satellite distribution in a tree structure Can be used for all international TV standards: B/G, D/K, I, L, M, CCIR/OIRT, PAL/SECAM/NTSC/digital TV Easy installation and connection Socket and plug to IEC 169-2 Can be installed in 55 flush mounting box (58 mm Ø) or in distance frame Please order termination resistor, frame and cover plate separately Quantity boxed: 10 pieces Shielding rate EMC class A up to 300 MHz > 85 db 470 MHz > 80 db 1000 MHz > 75 db 2400 MHz > 55 db Meets EN 50083-1, -2 GD 11 S Termination resistor R 77 DC for GD 11 S see last page of this section Other tap-off attenuations supplied on request Filter sockets Single socket Type ED 01 S Order No. 947 644-001 Throughpass socket Type For use in individual and in MATV installations on decoupled tap-off lines. Transmits remote feed voltage. GD 11 S Order No. 947 645-001 max. 24 V 500 ma 2 1 5-860 MHz 950-2400 MHz max. 24 V 500 ma 2 1 5-860 MHz 950-2400 MHz For use in MATV installations at the end of a trunk line with a large number of sockets. Transmits remote feed voltage. Connection cable FEKAB: For connecting a radio, TV or satellite receiver to an antenna outlet socket in accordance with IEC 169-2 Completely assembled, with angled coaxial plug and angled coaxial socket in accordance with IEC 169-2 SATKAB: For the connection of a satellite receiver to an antenna outlet socket with F-connectors Completely assembled, with 2 angled connectors Common features: White cable and connectors Packed in polythene bag Quantity boxed: 10 pieces Shielding rate 90 db IEC plug/socket Type FEKAB 1.5 m FEKAB 3 m Order No. 910 957-001 910 957-002 2 x F-quick connectors Type SATKAB 1.5 m SATKAB 3 m Order No. 947 665-150 947 666-150 Fig. FEKAB Length 1.5 m 3.0 m Frequency range 0.15-2400 MHz 0.15-2400 MHz Attenuation at 2050 MHz 2 db 4 db Adaptor IEC/F-connector F/IEC connector see SBFC.. Conn... sec. see SBFC.. Conn... sec. 134

RP VHF I FM LSC- UHF IV/V Sat IF VHF III ESC Frequency range MHz 5-40 47-68 87.5-108 125-470 470-862 950-2150 2150-2400 Connection attenuation 2 RF/TV (plug) db 1.0 1.0 1.0 1.0 1.2 20 25 1 Sat (socket) db 30 30 30 30 25 1.2 1.2 Coupling attenuation TV/Sat db 30 30 30 30 30-25 20 25 Remote feed voltage/current max. 24 V=/500 ma via satellite output Frequency range MHz 5-40 47-68 87.5-108 125-470 470-862 950-2150 2150-2400 Throughpass attenuation db 1.0 1.0 1.0 1.0 1.2 1.6 2.4 Connection attenuation 2 RF/TV (plug) db 11 11 11 11 11.5 25 30 1 Sat (socket) db 35 35 35 35 35 11.5 12.0 Coupling attenuation TV/Sat db 30 30 30 30 25 20 25 Directional attenuation output/tv db 30 30 30 30 30 35 30 output/sat db 35 35 35 35 35 20 15 Remote feed voltage/current max. 24 V=/500 ma via satellite output Accessory Termination resistors Type R 77 R 77 DC Order No. 910 508-002 947 691-001 For reflection-free termination Frequency range 0.15-2400 MHz Use with antenna outlet sockets, tapoffs, distribution boxes R 77 DC: DC capacitively isolated 135

Antenna Outlet Sockets For surface mounting of all Hirschmann antenna outlet sockets Color: ivory and white For antenna outlet sockets EDU..., GEDU..., FS... Associated cover plate AD 350 or ADR 20 with central plates Accessories Distance frame Type AR 20 Order No, ivory 910 382-002 white 910 382-005 For Hirschmann antenna outlet sockets EDU..., GEDU... and FS... Color: ivory and white Made of impact-proof plastic For standard range and also for some special types Dimensions: 81 x 81 mm Cover plate Type AD 350 Order No. ivory 910 460-202 white 910 460-205 For Hirschmann antenna outlet sockets EDU..., GEDU..., FS..., EDA..., GEDA... Made of impact-proof plastic Standard grid Please order cover plate separately Color: ivory and white Dimensions: 50 x 50 mm Central plate Type ADE 20 ADE 30 Order No. ivory 947 692-002 947 693-002 white 947 692-005 947 693-005 Suitable for Hirschmann central plates and distance frames Made of impact-proof plastic Colour ivory and white Dimensions: 75 x 75 mm Cover plate Type ADR 20 Order No. ivory 947 694-002 white 947 694-005 136

Connectors, Cable, Test Equipment Overview Connectors, Cable, Test equipment Coaxial IEC connectors Coaxial F-connectors Adapter plugs, adapter connectors, adapters, earth block House connecting box, adjustable attenuator Fixed attenuators Termination resistor for F-connectors Coaxial cable Level meters and Spectrum analyzers 137

Connec., Cable,Test Equipment Overview RF cable with matching connectors,, @@ ÀÀ,@ À,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ HÀ,ÀÀ À, @,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ, @ À @ À, H F-connectors KOKA... 702 712 780 724 2200 SAT 709 799 Digi 741 11 RG Screw-on plugs SFC 040 SFC 052 SFC 061 RG 59 SFC 070 Crimp plugs CFS 56 SUV SFC 250 W SFC 273 CFS 11 IEC connectors Plugs, male KOS 1 Z KOS 3 N KOSWI 3 Sockets, female KOK 1 Z KOK 3 N KOKWI 3 138

Coaxial connectors and angled connectors to IEC 169-2 Type KOS 1 Z KOK 1 Z Order No. 947 537-100 947 541-100 Version Plug, male Socket, female For cable with inner cond. Ø mm 0.5-1.0 0.5-1.0 outer cond. Ø mm max. 5.2 max. 5.2 sheath Ø mm max. 7.2 max. 7.2 Cable type KOKA 702, 709, KOKA 702, 709, 712, 799, 2200 SAT 712, 799, 2200 SAT Screw-less connection for inner conductor, no need for tools With strain relief Frequency range 0-2400 MHz Shielding rate at 470 MHz 75 db 470-862 MHz 70 db 950-1750 MHz 60 db 1750-2400 MHz 55 db Quantity boxed: 50 pieces in endless bags, assembled Color: white Type KOS 3 N KOK 3 N Order No. 947 539-100 947 546-100 Version Plug, male Socket, female For cable with inner cond. Ø mm 0.7-1.13 0.7-1.13 outer cond. Ø mm max. 5.2 max. 5.2 sheath Ø mm max. 7.8 max. 7.8 Cable type KOKA 702, 712, KOKA 702, 712, 709, 799, 2200 SAT 709, 799, 2200 SAT Screw connection for inner conductor With strain relief Frequency range 0-2400 MHz Shielding rate up to 862 MHz 75 db 950-1750 MHz 65 db 1750-2400 MHz 60 db Quantity boxed: 50 pieces in endless bags, assembled Color: white Type KOSWI 3 KOKWI 3 Order No. 947 544-100 947 548-100 Version Angled plug Angled socket For cable with inner cond. Ø mm max. 1.0 max. 1.0 outer cond. Ø mm max. 5.6 max. 5.6 sheath Ø mm 4.5-7.2 4.5-7.2 Cable type KOKA 702, 709, KOKA 702, 709, 712, 799, 2200 SAT 712, 799, 2200 SAT Screw connection for inner conductor With strain relief Frequency range 0-2400 MHz Shielding rate up to 862 MHz 75 db 862-1750 MHz 65 db 1750-2400 MHz 60 db Quantity boxed: 50 pieces in endless bags, assembled Color: white 139

Connec., Cable,Test Equipment Coaxial F-connectors Screw-on plugs Type SFC 040 SFC 052 Order No. 947 390-001 947 389-001 Frequency range 0-2400 MHz Quantity boxed 100 pieces For cable with outer Ø mm approx. 4.0 approx. 5.2 Cable type KOKA 724 KOKA 780 TWIN-SAT Screw-on plugs Type SFC 061 SFC 070 Order No. 947 371-001 947 388-001 Frequency range 0-2400 MHz Quantity boxed 100 pieces For cable with outer Ø mm approx. 6.1 approx. 7.0 Cable type RG 59 KOKA 702, 712, 709, 799, 2200 SAT Crimp plugs Type SFC 250 W SFC 273 CFS 11 Order No. 947 563-001 947 391-001 980 000-120 Frequency range 0-2400 MHz SFC 250 W water-proof, IP 67 Quantity boxed SFC 100 pieces CFS 11 5 pieces or 10 pieces For cable with braid Ø mm approx 5.0 approx. 7.3 8.0 Cable type KOKA 702, KOKA 741 KOKA 11 RG 712, 709, 799 Dimension a for crimp pliers a 0.360 0.475 0.475 /0.096 Crimp plug Type CFS 56 SUV Order No. 981 000-104 Frequency range 0-2400 MHz Water-proof, IP 67 For cable with dielectric mm approx 4.8 Cable type KOKA 2200 SAT Dimension a for crimp pliers a 0.360 140

Adapter plugs Type SBFC 01 SBFC 02 WFC 01 Order No. 947 395-001 947 415-001 947 372-001 Adapter IEC socket/ IEC socket/ F socket/ F-plug F-socket F-plug Frequency range 0-2400 MHz Quantity boxed Packed individually 10 pieces Packed together 100 pieces F-connector adapters Type KVFC 01 KVFC 02 Order No. 947 374-001 947 387-001 Adapter F-socket/ F-plug/ F-socket F-plug For connecting two RF cables, each with F-plugs or F-sockets Frequency range 0-2400 MHz Boxed quantity Packed individually 10 pieces Packed together 100 pieces IEC-connector adapters Type KVS 1 KVK 1 Order No. 947 194-001 981 000-107 For connecting two RF cables, each with double plug and socket to IEC 169-2 Frequency range 0-862 MHz Quantity boxed Packed individually 10 pieces Packed together 100 pieces F-quick connector Type KVFC 03 Order No. 947 591-001 For connecting two F-sockets Use, e.g., for cascading multi-switches Frequency range 0-2400 MHz Earth and F-connection block Type GBD-1 Order No. 980 000-160 Connecting any coaxial cable with F-connectors Simple option for earthing F-accessory Type GPF-591 Order No. 981 000-103 Test adapter for quick measurements Push on F-plug, threaded F-socket 141

Connec., Cable,Test Equipment House connection box Type HCB 862 Order No. 947 314-002 Connection between broadband cable distribution network and indoor distribution Connections: screw terminals Input: inner conductor Ø max. 2.2 mm, outer conductor Ø max. 8.8 mm Output: inner cond. Ø max. 1.7 mm, outer conductor Ø 7.5 mm Capacitive isolation of the inner conductor Max. earthing conductor connection 10 mm 2 Plastic outer housing Housing cover can be lead sealed Shielding rate up to 862 MHz 75 db IEC test socket on input and output Operating modes can be selected using switch S1 and S2 The technical data complies with the requirements of the FTZ (German Telecommunications Authority) Wall mounting Frequency range MHz 5-862 Throughpass attenuation db 0.8-1.5 Decoupling input/output db 50-45 Return loss 5-450 MHz db 20 ( 40-450 MHz 1 db per octave) 450-862 MHz db 10 Test voltage inner/outer conductor of the outside cable 2 kveff, 50 Hz Impedance Ω 75 Operating temperature C 20 to +55 Dimensions W x H x D mm 115 x 130 x 60 Adjustable attenuator Type VDF 18 F VDR 757 F Order No. 947 590-001 947 504-001 For reducing excessive signal levels Remote feed voltage is relayed Meets EN 50083-2 Frequency range MHz 47-2150 40-2150 Attenuation adjustment range db 18 20 Max. remote feed current 1 A/24 V DC 1 A/24 V DC Connections F-socket, F-plug IEC Dimensions mm 58 x 38 x 20 44 x 47 x 24 142

Fixed attenuators With IEC connections Type FDG 75/6 FDG 75/10 Order No. 947 107-106 947 107-110 Frequency range MHz 0.15-862 0.15-862 Attenuation db 6 10 Color ring coding red yellow With F-connections Type FDFC 6 FDFC 10 Order No. 947 445-006 947 445-010 Frequency range MHz 0.15-862 0.15-862 Attenuation db 6 10 For reducing excessive input levels, particularly when adjusting AGC amplifiers and converters (10 db value) Adapter plugs with fixed attenuation values Shielding rate up to 470 MHz 75 db 470-862 MHz 65 db For reducing excessive input levels, particularly when adjusting AGC amplifiers and converters (10 db value) Adapter plugs with fixed attenuation values Shielding rate up to 470 MHz 75 db 470-862 MHz 65 db Termination resistor Type RFC 75 Order No. 947 373-001 For terminating open outputs with F-connections Frequency range 0-2400 MHz Quantity boxed Packed individually 10 pieces Packed together 100 pieces 143

Connec., Cable,Test Equipment RF cable Type KOKA 702 KOKA 712 KOKA 724 Order No. 1) 100 m reel 198 702-100 198 712-100 - 200 m reel - - 128 111-002 500 m drum 198 702-500 198 712-500 -,, @@ ÀÀ,@ À,, @@ ÀÀ 75 Ω coaxial cable to EN 50117 Features Full PE cable Full PE cable with Full PE cable, thick braid, small diameter high return loss Preferred use Standard building Interactive CATV- Mini-cable for spaceinstallation up to building distribution saving installation 862 MHz installations, public (MATV) buildings, etc. Meter markings yes yes yes Diameter/material inner conductor mm 0.75/Cu 0.75/Cu 0.4 steel/cu insulation mm 4.8/PE 4.8/PE 2.6 full/pe outer conductor mm 5.5/AI/PET/AI foil Cu foil AI foil + Cu braid + 5.4 Cu braid + Cu braid tinned, blank, tinned, braid coverage 40% braid coverage 80% braid coverage 55% Sheath mm 6.8/PVC white 6.8/PVC white 4.1/PVC white 1) Ordering example for 300 m KOKA 712 in 100 m reel: 300 (m) KOKA 712/198 712-100 2) DC resistance of the loop consisting inner conductor and shield of a 100 m cable at +20 C Bending radius, min. one-time cm 3.5 7 6.5 DC resistance Ω 6.7 2) 5 2) 6.7 2) Shortening factor 0.66 0.66 0.66 Return 5-30 MHz db 23 26 20 loss 30-470 MHz db 23 26 20 470-862 MHz db 22 26 20 862-2150 MHz db 20 20 - Shielding 30-470 MHz db 75 90 75 rate 470-1000 MHz db 75 90 75 1000-2150 MHz db 65 85 70 Attenuation (100 m/20 C) 5 MHz db - - - 50 MHz db 5.7 5.5 10.0 100 MHz db 8.1 7.9 15.0 200 MHz db 11.7 11.4 21.5 400 MHz db 17.1 16.3-800 MHz db 24.8 23.9 44.0 1000 MHz db 27.7 26.5 50.8 1600 MHz db 36.9 36.1-2150 MHz db 43.3 40.3 76.4 2400 MHz db 46.5 44.5 - Fire load MJ/m 1.1 1.1 - Operating temperature C 25 to +70 25 to +70 25 to +70 144

RF cable Type KOKA 709 KOKA 2200 SAT KOKA 799 DIGI* Order No. 1) 100 m reel 198 709-100 128 114-001 Order-No. 300 m reel - 128 114-004 see below 500 m drum 198 709-500 128 114-003,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ Features Cell PE cable Full PE, cable Cell PE cable, physic. high shielding molded, low rate, silvered attenuation, high braid shielding rate, Preferred use SMATV installa- Universal for Universal for tions SAT IF and CATV SAT IF and CATV indoor installations indoor installations Meter markings yes yes yes Diameter/material inner conductor mm 1.1/Cu wire blank 0.75/steel Cu 1.13/Cu wire blank insulation mm 4.8/cell PE 4.5/full PE 4.8/cell PE physic. molded with outer layer outer conductor mm 5.6/AI/PET/AI foil double lines/ai 5.6/AI/PET/AI foil + alloy braid foil + Cu braid, + Cu braid, silvered tinned Sheath mm 6.8/PVC white 6.6/PVC white 6.8/PVC white+blk. Bending radius, min. one-time cm 7 3.5 7 DC resistance Ω 6.8 2) 7.0 2) 5 2) Shortening factor 0.82 0.66 0.8 Return 5-30 MHz db - 20 - loss 30-470 MHz db 18 20 23 470-862 MHz db 16 20 20 862-2150 MHz db 14 15 18 Shielding 30-470 MHz db 75 90 85 rate 470-1000 MHz db 75 95 90 1000-2150 MHz db 65 85 75 Attenuation (100 m/20 C) 5 MHz db 1.6-1.4 50 MHz db 4.4 58 4.2 100 MHz db 5.9 8.5 5.7 200 MHz db 8.2 11.9 8.0 400 MHz db 12.1-11.3 800 MHz db 18.0 25.6 16.8 1000 MHz db 20.5 29.4 19.1 1600 MHz db 27.2-25.1 2150 MHz db 31.6 44.2 29.0 2400 MHz db 33.4-30.8 Fire load MJ/m 0.66-0.66 Operating temperature C 25 to +70 25 to +70 25 to +70 * Order Nos KOKA 799 DIGI 198 799-101 (100 m, white PVC), reel 198 799-501 (500 m, white PVC),drum 198 799-102 (100 m, black PVC), reel 198 799-502 (500 m, black PVC), drum KOKA 799 FRNC FRNC type also halogen-free, flame-resistant 198 799-105 (100 m, white), reel 198 799-505 (500 m, white), drum 198 799-106 (100 m, black), reel 198 799-506 (500 m, black), drum 75 Ω coaxial cable to EN 50117 for KOKA 2200 Sat, KOKA 799 and KOKA 712 1) Ordering example for 1500 m KOKA 799 white FRNC on 500 m drums: 1500 (m) KOKA 799 FRNC/198 799-505 2) DC resistance of the loop consisting inner conductor and shield of a 100 m cable at +20 C 145

Connec., Cable,Test Equipment RF cable Type KOKA 780 TWIN-SAT KOKA 741 KOKA 11 RG Order No. 1) 100 m reel 198 780-100 - - 500 m drum - 198 741-500 198 011-500,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,ÀÀ, @ À,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ H H, @ À,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ,, @@ ÀÀ, @ À 75 Ω coaxial cable to EN 50117 Features Double Robust full PE Cell PE cable cell PE cable cable, low atten., very low attenuation, halogen-free halogen-free Preferred use 1st Sat IF for all CATV networks Trunk line for two and four trunk line Sat IF and CATV cable solutions building installations 1) Ordering example for 300 m KOKA 712 in 100 m reel: 300 (m) KOKA 712/198 712-100 2) DC resistance of the loop consisting inner conductor and shield of a 100 m cable at +20 C Meter markings yes - - Diameter/material inner conductor mm 0.8/Cu 1.1/Cu 1.63/steel Cu pl. insulation mm 3.5/cell PE 7.2/PE 7.25/cell PE outer conductor mm 4.2/AI/PET/AI foil 7.7/Cu band 8.1/AI/PET/AI foil + Cu braid overlapping + alloy braid tinned sheath mm 5.4x 11.5/PVC white 10.4/PE black 9.9/PE black Bending radius, min. one-time cm 3.5 10 6 DC resistance Ω 7.0 2) 2.4 2) 6.8 2) Shortening factor 0.85 0.66 - Return 5-30 MHz db 20 24 23 loss 30-470 MHz db 20 26 23 470-862 MHz db 20 23 20 862-2150 MHz db 15-20 Shielding 30-470 MHz db 75 75 85 rate 470-1000 MHz db 75 75 75 1000-2150 MHz db 65-65 Attenuation (100 m/20 C) 5 MHz db - - 0.8 50 MHz db 5.6 3.4 2.7 100 MHz db 8.1 5.3 3.8 200 MHz db 11.7 7.7 5.6 400 MHz db 16.9 11.5 8.1 800 MHz db 24.8 17.0 12.0 1000 MHz db 27.7-13.7 1600 MHz db 29.4-18.1 2150 MHz db 42.3-21.6 2400 MHz db 45.9-23.2 Fire loss MJ/m 0.8 - - Operating temperature C 25 to +70 25 to +70 25 to +70 146

Level meter, analog Type UPM 1500 Order No. 948 382-001 Frequency range: MHz 47-2150 TV standard Standard B/G, additional TV standards optional Digital video and Level measurement 64 QAM standard; level audio transmission measurement in QPSK standard Measurement precision db ± 1.5 (20 C)/ ±2.5 (0-40 C ) Measurement bandwidth: FM/TV-SC measurement khz 200 TV video carrier meas. khz 200 1st Sat IF MHz 27 Meas.- FM/TV dbµv 30-130 range 1st Sat IF dbµv 40-110 RF input IEC socket, 75 Ω; autom. input attenuation control/level correction calculated TV video display b/w screen, screen diagonal 14 cm blanking interval can be displ. via rotary switch Audio reproduction and Via built-in loudspeakers (FM, TV, Sat) measurement facilities TV sound carrier measurement SC 1 or SC2, SAT sound carrier can be tuned in10 khz steps from 5.00-9.75 MHz, acoustic level trend indication (tone), NICAM audio carrier meas. Spectrum analyzer Anal. analyzer with fast autom. sweep function in all bands; manual dynamic matching in analyzer mode for all bands; switching function TV picture/fm audio C/N measurement Assessment of the satellite receiving unit, adjust. facility for different transponder bandwidths Power- mains operation 230 V/115 V~, ±6%, 50-60 Hz/60 W supply battery operation Charger built-in, battery type 12 V/3.5 A (not included); battery life: normal operation 1.5 h; for LNB feed 18 V/200 ma-1h Protective measures Protection class II to VDE 0411 Dimensions W x H x D mm 380 x 160 x 350 (without handle) Level meter with analog analyzer for all bands (terr., broadband cable, SAT from 47-2150 MHz) 50 station memory locations, can be programmed as required with memory protection function TV screen Station search LNB feed voltage on input socket 0/14/18 V, I=500 ma Measurement of the LNB feed current 12 V voltage output 0/22 khz switching function DiSEqC 1.0, switching function Level measurement for 64 QAM standard Level measurement for QPSK standard Acoustic signal for antenna alignment C/N measurement LC display, illuminated, 2 x 16-digit, in German, English, French Concise instructions and accessory compartment in the lid, additional compartment for small parts Closed instrument with captive lid or removable lid All connections and controls accessible from the front Low weight, approx. 5.8 kg (without battery) Accessories included: mains cable, measuring cable, adapter, IEC, F-plug and carrying strap Options: TV standard B/G and one further standard from: D/K, M/N, L or I, bit error rate measurement (BER) for QPSK and QAM 147

Connec., Cable,Test Equipment Level meter, analog and digital Type UPM 2600 D Order No. 948 383-001 Level meter with digital analyzer for all bands (terr., broadband cable, SAT from 47-2150 MHz) 200 station memory locations, can be programmed as required with memory protection function TV screen b/w Station search Programmable RS 232 interface for printer connection, PC connection for remote control, monitoring, evaluation 20000 measured values can be stored Terrestrial remote feed for amplifiers DiSEqC 1.0 switching function Level measurement and bit error rate measurement for 64 QAM and QPSK signals Screen display of the constellation diagram for QAM Acoustic signal for antenna alignment LC display, illuminated, 2 x 16-digit, in German, English, French with level trend indication C/N measurement Video input Concise instructions and accessory compartment in the lid, additional compartment for small parts Closed unit with captive lid or removable lid All connections and controls accessible from the front Weight approx. 9.5 kg (without battery) Accessories included: mains cable, measuring cable, adapter, IEC and F- plugs Options (two standard version) TV standard B/G and one of the following additional TV standards: D/K (OIRT), M/N (FCC), L (France), I (UK), satellite video signal distribution (C band), polarizer control, pulsed/magnetic/ mechan. 12 V external power supply (input and output), software for PC, videotext can be retrofitted Frequency range MHz 47-2150 TV standard Standard B/G, addition TV standard optional Digital video and audio trans. Level meas. 64 QAM standard; bit error rate measurement in 64 QAM standard, QAM constellation diagram (symbol or state diagram), level meas. in QPSK standard, bit error rate meas. in QPSK standard Measurement precision db ± 1.5 (20 C)/ ± 2.5 (0-40 C ) Measurement bandwidth: FM/TV-SC measurement khz 200 TV video carrier meas. khz 200 1st Sat IF MHz 27 Measurement range FM/TV dbµv 30-130 1st Sat IF dbµv 40-130 RF input Ω IEC socket, 75; autom. input attenuation control/level correction calculated TV picture display b/w screen, screen diagonal 16 cm, zoom function: 50% enlarg. (horiz. and vertical), blanking interv. can be disp. per key Audio reproduction and Via built-in loudspeakers (FM TV, Sat) measurement facility TV sound carrier meas. SC1/2, SAT sound subcarrier can be tuned in 10 khz steps from 5.00-9.75 MHz, acoustic level trend indication (tone), NICAM audio carrier meas. Spectrum analyzer Digital analyzer, with fast automatic sweep function in all bands; broadband, narrow spectrum display; switching function TV picture/fm audio LNB supply and Feed voltage on input socket from control of 10-22 V/DC, adjustable in 0.1 V steps remote feed voltage at 400 ma; meas. of the LNB feed current; AC switching voltage (U pp =0.6V), adjustable from 0.2-30.0 khz Power supply mains operation 230 V/115 V~, ±6%, 50-60 Hz/60 W battery operation Charger built-in, battery type 12 V/6.5 A (not included); battery life: normal operation 3h; at LNB feed 18V/200 ma-2h Protective measures Protection class II to VDE 0411 Dimensions W x H x D mm 440 x 148 x 358 (without handle) 148

Level meter, analog and digital Type UPM 3300 Order No. 948 404-001 Frequency range MHz 5-2150 IF input MHz 38.9 TV standard, color standards PAL, SECAM, NTSC Frequency/channel entry Via keypad Satellite audio IF frequency MHz 5.00-9.99 in 10 khz steps, adjustable as req. RF input Ω IEC socket/75 (DIN 45 325) Measurement range FM/TV band dbµv 20-126 sat. band dbµv 40-126 IF measurement (38.9 MHz) dbµv 50-126 Return path (5-65 MHz) dbµv 20-126 Measurement precision db ±1.5 (at 20 C), ±2.5 (from 0 C to 40 C) Measured value memory Approx. 20,000 measured values DVB measurements Level measurement for QPSK and 64 QAM, BER for QPSK and 64 QAM-MER for 64 QAM constellation diagram for 64 QAM Symbol rate QAM 500...7000 kbd QPSK 3...30 MBd Code rate From 1 / 2 to 8 / 9 (automatic detection) TV audio carrier measurement Separate measurement for audio carrier I for stereo and dual sound and audio carrier II with acoustic reproduc. of transmissions audio I or II (NICAM audio carrier meas.) Spectrum analyzer Digital analyzer with switchable measurement bandwidths, for wide and narrow band display in all bands Printer 24-digit thermal printer LNB feed LNB feed, can be adjusted as required from 10-22 V (0.1 V steps), short-circuit proof, switching signal 22 khz and DiSEqC 1.0 Power supply 110-250 V~/50-60 Hz, 12 V external, battery 12 V/2.2 Ah (chg. time approx. 8 h.) Protective measures Protection class II to VDE 0411 Dimensions W x H x D mm 315 x 150 x 315 Level meter for analog and digital TV, with printer and real-time clock Frequency range 5-2150 MHz Videotext can be opened for each station With bit error rate measurement (BER) for QPSK and 64 QAM, constellation diagram and modulation error measurement (MER) DiSEqC and RDS output Graphic capable color LC display 5.5 full color Water and dirt resistant keypad Interface for MPEG-2 data stream, RS 232 interface, RDS output and SCART connection (video input and output) 12 V connecting socket Connection for stereo headphones As standard with built-in rechargeable battery 12 V/2.2 Ah, a second rechargeable battery can also be added Scope of delivery: measuring cable IEC- IEC, RF and F-adapters, mains cable, roll of paper for printer Weight 6.8 kg with one rechargeable battery Options: MPEG 2 decoder, S/N measuring module, ADR decoder or NICAM decoder Display of a satellite spectrum in narrow band mode. Cross polarizations become visible here. Constellation diagram for a 64 QAM signal. Display of the spectrum for a 1st satellite IF plane. Here level skewing can be seen. 149

Turboplaner II The planning program for Windows MFD-2HD 150