Digital Flow Switch for Water

Similar documents
Digital Flow Switch for Water 3 -color/2-screen display

3 -color/2 -screen display

Digital Flow Switch for Large Flow

Digital Flow Switch for Air/Water

Electromagnetic Type Digital Flow Switch

Electromagnetic Type Digital Flow Switch

Electromagnetic Digital Flow Switch

100 : 1. Digital Flow Switch. PFMB Series 66 % 67% 76 % 81% 2-Color Display (Only 200 L type) Compact, Space saving

3-color/ 2-screen display 1

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

Mechanical flow switch for On/Off control

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Digital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Digital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.

Digital Gap Checker. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air STEP 2 STEP 3

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Pressure Sensor. PSAN Series. Compact Digital Pressure Sensors. Features Pressure Measurement Range (Negative, Standard, Compound)

Electromagnetic Type Digital Flow Switch

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Single Point Flow Monitor SW118 SW119

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

PROPORTIONAL VALVES Sentronic plus

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Absolute Rotary Encoder E6CP

Selection matrix for electronic pressure switches

GC61 Digital Pressure Gauge. Operation Manual

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Flow Monitor PF3W3##

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

GC30 Digital Differential Pressure Gauge Operation Manual

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

FLOMAT Electromagnetic Insertion Flowmeter

Solid-State Digital Timer

Photoelectric Sensors E3F2

Absolute Encoders Multiturn

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Micro-Machined Silicon Transducers

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

Modular Lube Lubrication Systems System Controls

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Bimetal Temperature Switch

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Separate Thin Amplifier type. AP-V40AW Series

Signet 2250 Hydrostatic Level Sensor

Technical data. General specifications. Indicators/operating means

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

800 Displaying Series Flowmeter

02/11/2015

100:1. 74 % reduction. 78 % reduction. 1 l/min. Expanded flow range. Compact, Space saving. 3-Colour Display Digital Flow Switch

02/11/2015

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Hybrid Chart Recorder 250 mm (10")

Operating Instructions

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Linear encoders without bearings incremental System for linear motion feedback

Flow Switch. Flow Switch

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Model Number Structure

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

SQM40/41 Actuators for air and gas dampers

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Wall-/Pipe-Mount Level Indicator

SIGNET 5500 Flow Monitor ENGLISH

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Panel-mounting thermostats, type series EM

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Eddy Current Probe System

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

Digital Flow Monitor PFG3#0

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

LAUREL ELECTRONICS, INC.

Linear flow controls VFC Linear flow controls with actuator IFC

Contact-Type Digital Displacement Sensor. HG-S Series. User's Manual WUME-HGS panasonic.net/id/pidsx/global

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Installation and Maintenance Instructions for GC51 Rangeable Pressure Transmitter

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Gear Pump Units For single-line centralized lubrication systems

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Cylindrical Photoelectric Sensor CY-100 SERIES

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Photoelectrics Through-beam Type PA18C.T..., DC

Ø50mm Shaft Multi-Turn Absolute Type

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Transcription:

3-color display New Digital Flow Switch for Water RoHS IP65 3-color / 2-screen display Main screen Sub screen Note 3) Main screen Sub screen Note 3) Instantaneous flow rate Set value Note ) ccumulated value Peak/Bottom value Instantaneous flow rate Note ) Line name Fluid temperature Note ) Main screen shows the instantaneous flow rate only. Note 2) Fluid temperature can be displayed only when the digital flow switch with a temperature sensor is selected. Note 3) Sub screen can be turned off. Note 2) Integrated flow adjustment valve and temperature sensor New Flow adjustment valve Line up remote type New Lineup PVC piping type New Remote sensor unit Temperature sensor Series Remote type 3-color display Digital flow monitor pplicable fluid: Deionized water, chemical, etc. Flow rate range: to L/min Integrated type and remote type added to series. CT.ES-8B

Digital Flow Switch for Water 4% 4% smaller than existing product 7 66.4 Reducing piping space Shortened 74-3 PF2W74-3 (Existing product) 3 5 Straight piping length 42 PF2W74 74 Existing product requires a straight piping length at least 8 times the piping diameter. Temperature sensor Display range: to C (Temperature sensor alone) Minimum setting unit: C nalog output: Current output/voltage output Flow adjustment valve Space saving and reduced piping labor Temperature display Temperature sensor Fluid temperature: to 9 C Ethylene glycol aqueous solution can be used Example) Flow control of the circulating fluid in a chiller Customer s machine Rotatable display Display can be rotated in increments of 45 to suit the installation conditions. Easy operation, improved visibility. Counterclockwise 9 Clockwise 225 35 turn OUT IN OUT (No rotation) Non-grease Mounting OUT IN 8 turn 9 turn IN Bracket mounting Direct mounting Panel mounting Front protective cover Panel mount adapter Features Tapping screw (4 pcs.) Waterproof seal (accessory) Panel Mounting screw (M3 x 8 L) (accessory)

Series /min added L/min Monitor How to Order 2 to 6 3/8, /2 5 to 4 /2, 3/4 Specifications (Integrated Display) 2 to 3/4, Specifications (Remote Sensor Unit) 3 Flow-rate Characteristics (Pressure Loss) 4 PVC piping Integrated type Deionized water Remote sensor to 25 Example of Internal Circuit and Wiring 5, 6 Made to Order 6 Chemical Monitor Description/ Wetted Parts Construction 7 Dimensions 8 3-color display Digital flow monitor can copy to up to switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. 3-Color Display Digital Flow Switch for PVC Piping Copy How to Order Reducing setting labor Minimizing risk of mistakes in setting Specifications (Integrated Display) 2 Master sensor (source of copy) Slave side unit (copy destination) 2 units units Specifications (Remote Sensor Unit) 3 Description/ Wetted Parts Constructions 4 Dimensions 5 Indicator Visually check status of sensor via indicator. Reducing wiring labor by connector e-con connector No tools and peeling required Blinking green/fast Flow rate: Low Blinking green/slow Rated flow or less OFF Rated flow or more Red ON PVC piping type How to Order 6 Specifications 7 Example of Internal Circuit and Wiring 8, M8 connector Flow rate: High 3-Color Display Digital Flow Monitor for Water 3 9 Description (Remote Monitor Unit) 9 Dimensions 2 Power supply/output connection lead wire sensor 3/8 3-Color Display Digital Flow Switch for PVC Piping Ethylene glycol aqueous solution Remote.5 to 4 3 Water 3-Color Display Digital Flow Monitor for Water Integrated 3-Color Display Digital Flow Switch for Water Flow adjustment valve/temperature sensor Rated pplicable Port size Flow Flow adjustment flow range Temperature fluid adjustment valve + Tempera- Rc, NPT, G None sensor (L/min) valve ture sensor Type 3-Color Display Digital Flow Switch for Water INDEX Variations Wetted Parts Pipe CPVC (Heat resistant PVC) Body PPS Seal FKM Details 2 Features 2 Details Measured flow rate

3-color display Digital Flow Switch for Water Series How to Order RoHS Remote sensor unit Integrated display 5 7 5 4 3 T 7 4 3 T M Type Remote sensor unit Integrated display Rated flow range (Flow range) Symbol 4 2 4 adjustment valve 4 None Yes Rated flow range.5 to 4 L/min 2 to 6 L/min 5 to 4 L/min to L/min Flow adjustment valve With/without flow Rated flow rate Symbol 2 4 Nil S L/min type is not available with flow adjustment valve. Note ) External input: The accumulated value, peak value, and bottom value can be reset. Note 2) For units with temperature sensor, OUT2 can be set as either temperature output or flow rate output. Setting when shipped is for temperature output. Options/Part No. Remote sensor unit Output specification/temperature sensor Symbol OUT OUT2 Flow rate Temperature nalog to 5 V 2 nalog 4 to 2 m T nalog to 5 V nalog to 5 V Thread type Nil Rc N NPT F G OUT OUT2 Symbol Flow rate Flow rate Temperature nalog to 5 V nalog 4 to 2 m nalog to 5 V nalog 4 to 2 m External input Note ) External input Note ) () () Note 2) Note 2) (nalog to 5 V) Note 2) nalog to 5 V B C D E F G H T BT CT DT ET FT (nalog 4 to 2 m) (nalog to 5 V) (nalog 4 to 2 m) Symbol 3 4 6 Note 2) Note 2) Note 2) Port size 3/8 /2 3/4 / Integrated display Output specification/ Temperature sensor Temperature sensor nalog 4 to 2 m nalog to 5 V nalog 4 to 2 m Port size Rated flow range 4 2 4 When optional parts are required separately, use the following part numbers to place an order. Description Part no. Qty. Note Bracket Note) ZS-4-K ZS-4-L ZS-4-M For 74/72/54/52 For 74/54 For 7/5 With 4 tapping screws (3 x 8) With 4 tapping screws (3 x 8) With 4 tapping screws (4 x ) Lead wire with M8 connector ZS-4- Lead wire length (3 m) Note) For units with flow adjustment valve, 2 brackets are required. Remote sensor unit/ Instantaneous ccumulated Unit printed on label Symbol flow rate flow Temperature Nil G F L/min gal/min gal/min L gal gal C C F Temperature sensor J L/min L F Under the New Measurement Law, units other than SI (symbol: M ) cannot be used in Japan. None With temperature sensor Note) G, F, J: Made to Order Reference: [L/min].2642 [gal/min] [gal/min] 3.785 [L/min] F = 9/5 C + 32 None With temperature sensor Bracket (Option) Nil None Bracket R Made to Order X9 Seal material EPDM (Refer to page 6.) Calibration certificate (Only flow sensor) Nil None With calibration certificate The certificate is written in both English and Japanese. Integrated display type with temperature sensor can only display flow rate. Integrated display/unit specification Symbol Instantaneous ccumulated flow rate flow Temperature M G F J L/min gal/min gal/min L/min L gal gal L C C F F Under the New Measurement Law, units other than SI (symbol: M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].2642 [gal/min] [gal/min] 3.785 [L/min] F = 9/5 C + 32 Lead wire Nil With lead wire with M8 connector (3 m) N Without lead wire with M8 connector

3-color display Digital Flow Switch for Water Series Specifications (Integrated Display) Model 74 72 74 7 pplicable fluid Detection method Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex Rated flow range.5 to 4 L/min 2 to 6 L/min 5 to 4 L/min to L/min Display flow range.35 to 5.5 L/min.7 to 22. L/min 3.5 to 55. L/min 7 to 4 L/min (Flow under.35 L/min is displayed as. ) (Flow under.7 L/min is displayed as. ) (Flow under 3.5 L/min is displayed as. ) (Flow under 7 L/min is displayed as ) Set flow range.35 to 5.5 L/min.7 to 22. L/min 3.5 to 55. L/min 7 to 4 L/min Minimum setting unit. L/min. L/min L/min Conversion of accumulated pulse (Pulse width: 5 ms).5 L/pulse. L/pulse.5 L/pulse L/pulse Fluid temperature Display unit ccuracy Repeatability Temperature characteristics Operating pressure range Note 3) Proof pressure Note 3) Pressure loss ccumulated flow range Note 4) to 9 C (with no freezing and condensation) Instantaneous flow rate: L/min, ccumulated flow: L Display value: ±3% F.S. nalog output: ±3% F.S. ±2% F.S. Note 2) ±5% F.S. (25 C reference) to MPa.5 MPa 45 kpa at the maximum flow (without flow adjustment valve) 99999999.9 L 999999999 L By. L By.5 L By L Switch output Maximum load current Maximum applied voltage Internal voltage drop Response time Note 2), 5) Output protection Output Flow rate mode Temperature Response time Note 6) nalog output Voltage output Current output Hysteresis External input Display method Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Note 7) Insulation resistance Standards and regulations Wetted parts material Note 8) Piping port size Weight Without temperature sensor/without flow adjustment valve With temperature sensor/without flow adjustment valve Without temperature sensor/with flow adjustment valve With temperature sensor/with flow adjustment valve With lead wire with connector Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 4. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Note 2) When.5 s is selected for the response time of the switch output, the repeatability becomes ±3% F.S. Note 3) Operating pressure range and proof pressure change according to the fluid temperature. Refer to page 3. Note 4) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every 2 or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 24 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note 5) The response time when the set value is 9% in relation to the step input. (The response time is 7 s when it is output by the temperature sensor.) Note 6) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Note 7) When the temperature sensor is used, it will be 25 VC. Note 8) Refer to Wetted Parts Construction on page 7 for details. Temperature Sensor Specifications Rated temperature range Setting/Display temperature range Minimum setting unit Display unit Display accuracy nalog output accuracy Response time mbient temperature characteristics Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9 C. Note 2) The response time is for the temperature sensor alone. or open collector output 8 m 28 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current).5 s/ s/2 s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. Select from hysteresis mode or window comparator mode..5 s/ s/2 s (linked with the switch output) Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer 2-screen display (Main screen: 4-digit, 7-segment, 2-color, Red/Green Sub screen: 6-digit, -segment, White) Display values updated 5 times per second Output, Output 2: Orange 2 to 24 VDC ±% 5 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between whole live part and enclosure 5 MΩ or more (5 VDC mega meter) between whole live part and enclosure CE marking, UL (CS), RoHS PPS, Stainless steel 34, FKM, SCS3 Non-grease 3/8 2 g 285 g 3 g 385 g to C Note ) to C C C ±2 C ±3% F.S. 7 s Note 2) ±5% F.S. 3/8, /2 26 g 335 g 36 g 435 g +85 g /2, 3/4 4 g 53 g 6 g 73 g The output related to the temperature sensor is OUT2 only. Flow rate detecting circuit Temperature detecting circuit 3/4, 72 g 86 g OUT Switch output OUT2 Switch output nalog output The OUT2 can be selected from the output for temperature or flow rate by button operation. Black OUT White OUT2 2 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Details

Series Specifications (Remote Sensor Unit) Model 54 52 54 5 pplicable fluid Detection method Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex Rated flow range.5 to 4 L/min 2 to 6 L/min 5 to 4 L/min to L/min Fluid temperature ccuracy Repeatability Temperature characteristics to 9 C (with no freezing and condensation) ±3% F.S. ±2% F.S. ±5% F.S. (25 C reference) Operating pressure range Note 2) Proof pressure Note 2) Pressure loss Response time Note 3) nalog output Voltage output Current output Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Note 4) Insulation resistance Standards and regulations Wetted parts material Note 5) Piping port size Without temperature sensor/without flow adjustment valve With temperature sensor/without flow adjustment valve Without temperature sensor/with flow adjustment valve With temperature sensor/with flow adjustment valve With lead wire with connector Weight Refer to page 7 for monitor specifications. to MPa Note 2).5 MPa 45 kpa or less at the maximum flow (without flow adjustment valve) s Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC For power supply status, flow rate indicator (Blinking speed changes in response to flow rate), and other error indicator 2 to 24 VDC ±% 3 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between whole live part and enclosure 5 MΩ or more (5 VDC mega meter) between whole live part and enclosure CE marking, UL (CS), RoHS PPS, Stainless steel 34, FKM, SCS3 Non-grease 3/8 95 g 27 g 295 g 37 g 3/8, /2 245 g 32 g 345 g 45 g +85 g /2, 3/4 395 g 55 g 595 g 75 g 3/4, 75 g 84 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 4. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Note 2) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graphs below. Note 3) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Note 4) When the temperature sensor is used, it will be 25 VC. Note 5) Refer to Wetted Parts Construction on page 7 for details. nalog Output Temperature Sensor Specifications Rated temperature range to C Note ) nalog output ±3% F.S. accuracy Response time 7 s Note 2) mbient temperature ±5% F.S. characteristics Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9 C. Note 2) The response time is for the temperature sensor alone. Flow rate/nalog output Voltage output Current output B C V.5 V (.4 V) 5 V Output 4 m 6 m (5.6 m) 2 m C Values in parentheses are for the 7/5. Model Rated flow [L/min] Minimum Maximum 74/54 72/52 74/54 7/5.5 2 5 4 6 4 Minimum rated flow Operating Pressure and Proof Pressure B Maximum Flow rate rated flow Fluid temperature/nalog output 7/5 Voltage output Current output Voltage output Current output.6 V 2.4 m C 5 V 2 m B V 4 m D 5.4 V 2.6 m Output D C B C C C C Fluid temperature 74/72/74/54/52/54 Pressure [MPa] 3.6.4.2 Proof pressure [MPa].8.6 Operating pressure [MPa].4.2 5 9 Fluid temperature [ C] 74S/72S/74S/54S/52S/54S Pressure [MPa].6.4.2 Proof pressure [MPa].8.6 Operating pressure.4 [MPa].2 2 4 6 8 9 Fluid temperature [ C] 7/5 Pressure [MPa].6.4.2.8.6.4.2 Proof pressure [MPa] Operating pressure [MPa] 2 3 4 5 6 7 8 9 Fluid temperature [ C]

3-color display Digital Flow Switch for Water Series Flow-rate Characteristics (Pressure Loss: Without Flow djustment Valve) 74/54 Pressure loss [MPa] Pressure loss [MPa].4.3.2..4.3.2... 2. 3. 4. 74/54 Flow rate [L/min] 5 5 2 25 3 35 4 74/54 ccuracy [% F.S.] 74/54 ccuracy [% F.S.] Flow rate [L/min] Pressure:.3 MPa Piping diameter: ø2 ± ±9 ±8 ±7 ±6 ±5 74/54-3 (at 4 L/min) ±4 ±3 ±2 ± ± 2 4 6 8 Straight piping length [cm] ± ±9 ±8 ±7 ±6 ±5 74/54-4 (at 4 L/min) ±4 ±3 ±2 74/54-6 (at 4 L/min) ± ± 2 4 6 8 Straight piping length [cm] Pressure loss [MPa].4.3.2. 2 4 6 8 2 4 6 Flow rate [L/min] Straight Piping Length and ccuracy (Reference Value) Straight piping length 72/52 7/5 Pressure loss [MPa] The smaller the piping size, the more the product is affected by the straight piping length. Fluid pressure has almost no affect. Low flow rate lessens the effect of the straight piping length. Use a straight pipe that is 8 cm or longer in length to satisfy the ±3% F.S. specification. ( cm or longer for L/min type) 72/52 ccuracy [% F.S.] Pressure:.3 MPa Piping diameter: ø2 Pressure:.3 MPa Pressure:.3 MPa Piping diameter: 25 (Port size ) Piping diameter: ø6 7/5 2 (Port size 6) ccuracy [% F.S.].4.3.2. 2 4 6 8 ± ±9 ±8 ±7 ±6 ±5 ±4 ±3 ±2 ± ± Flow rate [L/min] 72/52-3 (at 6 L/min) 72/52-4 (at 6 L/min) 72/52-3 (at 8 L /min) 2 4 6 8 Straight piping length [cm] ±6 ±4 ±2 7/5-6 (at L/min) 7/5- ± (at L/min) 7/5-6 ±8 (at 5 L/min) ±6 ±4 ±2 7/5- (at 5 L/min) ± 2 4 6 8 Straight piping length [cm] No data for 4 cm, or for under 5 cm, as these cannot be used due to piping dimensions. Flow-rate Characteristics of Flow djustment Valve 74S/54S Flow rate [L/min] 72S/52S Flow rate [L/min] 74S/54S Flow rate [L/min] Measurable Range for Ethylene Glycol queous Solution (Reference Value) queous solution concentration [%] (Weight) 6. 4. 2. 2. 5.. 5. ΔP =.4 MPa ΔP =.3 MPa ΔP =.2 MPa ΔP =. MPa 2 4 5 Number of rotations [rotations] ΔP: Pressure differential between the front and the rear of product ΔP =.5 MPa ΔP =.4 MPa ΔP =.2 MPa ΔP =. MPa 2 4 5 Number of rotations [rotations] ΔP: Pressure differential between the front and the rear of product 6 5 4 3 2 ΔP =.3 MPa ΔP =.5 MPa ΔP =.4 MPa ΔP =.5 MPa ΔP =.3 MPa ΔP =.2 MPa ΔP =. MPa 2 3 4 5 6 7 8 Number of rotations [rotations] ΔP: Pressure differential between the front and the rear of product 9 8 7 6 5 4 3 Measurable within this range 2 2 3 4 5 6 7 8 9 queous solution temperature [ C] 4 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Details

Series Example of Internal Circuit and Wiring/Series 7 (Integrated Display) 2 Output type 7 - -(T)- 2 Output type 7 - -B(T)- Black OUT White OUT2 2 to 24 VDC Black OUT White OUT2 2 to 24 VDC + nalog output type 7 - -C(T)- + nalog output type 7 - -D(T)- + nalog output type 7 - -E(T)- + nalog output type 7 - -F(T)- Black OUT White nalog output 2 to 24 VDC Black OUT White nalog output 2 to 24 VDC + External input type 7 - -G- + External input type 7 - -H- Black OUT White External input 2 to 24 VDC Black OUT White External input 2 to 24 VDC Example of wiring for accumulated pulse output 2 Output type 7 - -(T)- + nalog output type 7 - -C(T)- /7 - -D(T)- + External input type 7 - -G- 2 Output type 7 - -B(T)- + nalog output type 7 - -E(T)- /7 - -F(T)- + External input type 7 - -H- Black OUT White OUT2 (7 (T) only) V or 5 ms 5 ms Black OUT White OUT2 (7 B(T) only) V or 5 ms 5 ms When accumulated pulse output is selected, indicator light turns off. 5

3-color display Digital Flow Switch for Water Series Example of Internal Circuit and Wiring/Series 5 (Remote Sensor Unit) nalog 2 Output type 5 - - Black OUT nalog output (Flow rate) White OUT2 nalog output (Temperature) OUT2 (white wire) only for units with temperature sensor 2 to 24 VDC 3-Color Display Digital Flow Switch for Water Made to Order Seal material for wetted parts changed to EPDM 5 7 Refer to How to Order, page for details. Note) Not compatible with units with flow adjustment valve. Please special-order separately. X9 X9 Seal material EPDM Please consult SMC for detailed dimensions, specifications and delivery. Symbol -X9 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Details 6

Series Description Main unit Integrated display (With temperature sensor and flow adjustment valve) Remote sensor unit (With temperature sensor and flow adjustment valve) Flow adjustment knob Lock ring FLOW indicator Connector Lead wire with M8 connector (Option) Piping port (OUT side) Flow adjustment valve (When the unit with flow adjustment valve is selected) POWER indicator Piping port (IN side) Bracket (Option) Temperature sensor (When the unit with temperature sensor is selected.) Display Output display (Indicator light) Sub screen Main screen (2-color display) Unit display UP button SET button DOWN button Wetted Parts Construction Description Connector Lead wire with M8 connector Piping port Bracket Temperature sensor Flow adjustment valve Flow adjustment knob Lock ring POWER indicator FLOW indicator Description Main screen (2-color display) Sub screen Output display (Indicator light) Unit display UP button SET button DOWN button Connects the lead wire. Supplies power to the product and ensures output. Connects to the piping. Inlet piping goes to the IN side, and outlet piping goes to the OUT side. Mounting bracket for installation of the product Detects the fluid temperature. Orifice mechanism to adjust the flow rate djusts the flow rate. Fixes the flow adjustment knob in place. Indicates the power supply status, indicates product specifications and indicates errors. Blinks at a cycle proportional to the flow rate or indicates errors. Turns off when below rated flow. Displays the flow, status of setting mode, and error code. Displays the accumulated flow, set value, peak/bottom value, fluid temperature, and line name. In the setting mode, the set status is displayed. (Refer to page 2 for details.) Displays the output status of OUT and OUT2. When ON: Orange light turns on. Displays the unit selected. Selects the mode and the display shown on the sub screen, and increases the ON/OFF set values. Press this button to change the mode and to set a set value. Selects the mode and the display shown on the sub screen, and decreases the ON/OFF set values. 7 o i q r w t w e y w u!2! w!3! w Component Parts No. Description ttachment 2 Seal 3 Body 4 Sensor 5 6 7 8 9 2 3 Temperature sensor Temperature sensor body Flow adjustment valve body Flow adjustment valve cover Flow adjustment valve shaft Shaft support O-ring Cap seal Y seal Material SCS3 FKM PPS PPS Stainless steel 34 Stainless steel 34 PPS PPS Stainless steel 34 PPS FKM FKM FKM Note Stainless steel 34 equivalent With brazing JIS Z 326: Bg-7, ISO 3677: B-g56CuZnSn-62/65 ( )

3-color display Digital Flow Switch for Water Series Dimensions 74/72/74/7 Integrated display Connector pin number Example 3 4 54/52/54/5 Remote sensor unit 2 G Z Pin no. 2 3 4 Y D.4 E F Y Pin name DC (+) OUT2 DC ( ) OUT F DD E 2 x piping port B 3 IN N B 3 5 J S (35.5) H K J T U 42 L 4 x WX 4 x P V W OUT V W 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping G Z 2 x piping port IN N S T U H 42 (35.5) K L 4 x WX 4 x P OUT 3-Color Display Digital Flow Monitor for Water 3 Model 74/54 72/52 74/54 7/5 Port size (Rc, NPT, G) 3/8 3/8, /2 /2, 3/4 3/4, 7 78 98 24 5 54 7 92 B 3 3 38 46 D 6 6 68 77 DD 45.6 45.6 53.6 62.6 E 4.6 4.6 48.6 57.6 F 5.2 5.2 9.2 23. G 24 27 32 4 H 4 8 28 42 J 35 39 49 63 K 26 3 35 48 L 8 8 28 28 N 3.6 3.6 6.8 8. P ø2.7 depth 4 ø2.7 depth 2 ø2.7 depth 2 ø3.5 depth 4 S 24 28 34 44 T 22 22 3 36 Bracket dimensions U 32 32 42 48 V 4 4 48 58 W 5 5 58 7 WX 4.5 4.5 4.5 5.5 Y 5 5 5 7 (mm) Z.5.5.5 2. 8 Details

Series Dimensions 74/72/74/7- - T Integrated display: With temperature sensor 54/52/54/5- - T Remote sensor unit: With temperature sensor (mm) Model 74/54- - T 72/52- - T 74/54- - T 7/5- - T 8 89 9 35 5 54 7 92 74S/72S/74S Integrated display: With flow adjustment valve 54S/52S/54S Remote sensor unit: With flow adjustment valve S D T S D T Q Q B F K L N B F K L 4 x P 4 x P N (mm) Model 74S/54S 72S/52S 74S/54S 9 4 2 42 5 54 7 B 63.6 (Max. 68.6) 63.6 (Max. 68.6) 75.25 (Max. 8) D 7.2 74.2 94.5 F 34 34 44 K 58.5 62.5 79. L 8 8 28 N 3.6 3.6 6.8 P ø2.7 depth ø2.7 depth ø2.7 depth Q ø9 ø9 ø28 Q number of rotations 6 6 7 Bracket dimensions S T 56.5 22 6.5 22 78. 3

3-color display Digital Flow Switch for Water Series Dimensions 74S/72S/74S- - T Integrated display: With temperature sensor and flow adjustment valve D S 54S/52S/54S- - T Remote sensor unit: With temperature sensor and flow adjustment valve D S 3-Color Display Digital Flow Switch for Water K (mm) K 3-Color Display Digital Flow Switch for PVC Piping Model D K S 74S/54S- - T 72S/52S- - T 74S/54S- - T (Black) 4 (Blue) 3 M8 2 (White) (Brown) ø 5 23 53 ZS-4- Lead wire with M8 connector Pin no. Pin name Wire color 2 3 4 DC (+) OUT2 DC ( ) OUT Brown White Blue Black 5 8.2 69.5 67.5 54 85.2 73.5 7.5 7 5.5 9. 89. (32.8) ø4 (3) (45) (5) Note) 4-wire type lead wire with M8 connector used for the series. Lead Wire Specifications Nominal cross WG23 Conductor section O.D. Material Insulator O.D. Color Material Sheath Finished O.D. pprox..7 mm Heat resistant PVC pprox.. mm Brown, White, Black, Blue Heat and oil resistant PVC ø4 3-Color Display Digital Flow Monitor for Water 3 Details

Remote sensor unit Integrated display Series Remote sensor unit/output specification Symbol OUT nalog to 5 V 2 nalog 4 to 2 m 5 7 3-color display Digital Flow Switch for PVC Piping 5 U 25 7 U 25 M Type Remote sensor unit Integrated display How to Order Remote sensor unit/ Unit printed on label Symbol Instantaneous ccumulated flow rate flow Temperature Nil L/min L C G gal/min gal C F gal/min gal F J L/min L F Under the New Measurement Law, units other than SI (symbol: M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].2642 [gal/min] [gal/min] 3.785 [L/min] F = 9/5 C + 32 Calibration certificate (Only flow sensor) Nil Bracket (Option) Nil None Bracket RoHS None With calibration certificate The certificate is written in both English and Japanese. Rated flow range (Flow range) Symbol Rated flow range to L/min Connection type U PVC pipe PVC pipe O.D. Symbol Port size 25 25 Integrated display/output specification Symbol OUT OUT2 B C D E F G H nalog to 5 V nalog 4 to 2 m nalog to 5 V nalog 4 to 2 m External input External input External input: The accumulated value, peak value, and bottom value can be reset. R Integrated display/unit specification Symbol Instantaneous ccumulated flow rate flow Temperature M L/min L C G gal/min gal C F gal/min gal F J L/min L F Under the New Measurement Law, units other than SI (symbol: M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].2642 [gal/min] [gal/min] 3.785 [L/min] F = 9/5 C + 32 Lead wire Nil With lead wire with M8 connector (3 m) N Without lead wire with M8 connector Options/Part No. When optional parts are required separately, use the following part numbers to place an order. Description Part no. Qty. Note Bracket Lead wire with M8 connector ZS-4-M ZS-4- With 4 tapping screws (4 x ) Lead wire length (3 m)

3-color display Digital Flow Switch for PVC Piping Series Specifications (Integrated Display) Model pplicable fluid Detection method Rated flow range Display flow range Set flow range Minimum setting unit Conversion of accumulated pulse Fluid temperature Display unit ccuracy Repeatability Temperature characteristics Operating pressure range Note 3) Proof pressure Note 3) Pressure loss ccumulated flow range Note 4) Switch output Maximum load current Maximum applied voltage Internal voltage drop Response time Note 2), 5) Output protection Output mode Flow rate Response time Note 6) nalog output Voltage output Current output Hysteresis External input Display method Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Wetted parts material Note 7) Piping port size Without lead wire with connector Weight With lead wire with connector 7 Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex to L/min 7 to 4 L/min (Flow under 7 L/min is displayed as ) 7 to 4 L/min L/min L/pulse to 7 C (with no freezing and condensation) Instantaneous flow rate: L/min, ccumulated flow: L, Display values updated 5 times per second Display value: ±3% F.S. nalog output: ±3% F.S. ±2% F.S. Note 2) ±5% F.S. (25 C reference) to MPa MPa 45 kpa or less at the maximum flow 999999999 L By L or open collector output 8 m 28 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current).5 s/ s/2 s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode..5 s/ s/2 s (linked with the switch output) Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer 2-screen display (Main screen: 4-digit, 7-segment, 2-color, Red/Green Sub screen: 6-digit, -segment, White) Output, Output 2: Orange 2 to 24 VDC ±% 5 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between whole live part and enclosure 5 MΩ or more (5 VDC mega meter) between whole live part and enclosure CE marking, UL (CS), RoHS PPS, FKM, CPVC Non-grease Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 4. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Refer to the list of applicable fluids on page 24. Note 2) When.5 s is selected for the response time of the switch output, the repeatability becomes ±3% F.S. Note 3) Operating pressure range and proof pressure change according to the fluid temperature. Refer to page 3. Note 4) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every 2 or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 24 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note 5) The response time when the set value is 9% in relation to the step input. Note 6) The response time until the set value reaches 9% in relation to the step input. Note 7) Refer to Wetted Parts Construction on page 4 for details. 25 285 g 37 g 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Details 2

Series Specifications (Remote Sensor Unit) Refer to page 7 for monitor specifications. Model pplicable fluid Detection method Rated flow range Fluid temperature ccuracy Repeatability Temperature characteristics Operating pressure range Note 2) Proof pressure Note 2) Pressure loss Response time Note 3) nalog output Voltage output Current output Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Wetted parts material Note 4) Piping port size Without lead wire with connector Weight With lead wire with connector 5 Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex to L/min to 7 C (with no freezing and condensation) ±3% F.S. ±2% F.S. ±5% F.S. (25 C reference) to MPa Note 2) MPa 45 kpa or less at the maximum flow s Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC For power supply status, flow rate indicator (Blinking speed changes in response to flow rate), and other error indicator 2 to 24 VDC ±% 3 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between whole live part and enclosure 5 MΩ or more (5 VDC mega meter) between whole live part and enclosure CE marking, UL (CS), RoHS PPS, FKM, CPVC Non-grease 25 27 g 355 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 4. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Refer to the list of applicable fluids on page 24. Note 2) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graphs below. Note 3) The response time until the set value reaches 9% in relation to the step input. Note 4) Refer to Wetted Parts Construction on page 4 for details. nalog Output Flow rate/nalog output Voltage output Current output V 4 m B C.4 V 5 V 5.6 m 2 m Rated flow [L/min] Model Minimum Maximum 7/5 Flow-rate Characteristics (Pressure Loss) 7/5 Pressure loss [MPa].4.3.2. 2 4 6 8 Flow rate [L/min] Output C B Minimum rated flow Maximum Flow rate rated flow Straight piping length Fluid pressure has almost no effect. To maintain ±3% F.S. in the specificatioins, use a straight pipe that is cm or longer in length. Operating Pressure 7/5 (for PVC Piping) Max. operating pressure [MPa].2.8.6.4.2 2 3 4 5 Fluid temperature [ C] 6 7 8 9 Straight Piping Length and ccuracy (Reference Value) 7/5 ccuracy [% F.S.] ± ±8 ±6 ±4 ±2 Pressure:.3 MPa Piping diameter: 25 7/5-U25 (at L/min) ± 2 4 6 8 Straight piping length [cm] 3 For measurable range for ethylene glycol aqueous solution (reference values), refer to page 4. For examples of internal circuit and wiring, refer to pages 5 to 6.

3-color display Digital Flow Switch for PVC Piping Series Description Main unit Lead wire with M8 connector (Option) Connector Integrated display (PVC piping) Piping port (OUT side) Remote sensor unit (PVC piping) FLOW indicator POWER indicator 3-Color Display Digital Flow Switch for Water Piping port (IN side) Display Output display (Indicator light) Sub screen Bracket (Option) Main screen (2-color display) Unit display UP button SET button DOWN button Wetted Parts Construction q t w e r w t Description Connector Connects the lead wire. Lead wire with M8 connector Supplies power to the product and ensures output. Piping port Connects to the piping. Inlet piping goes to the IN side, and outlet piping goes to the OUT side. Bracket Mounting bracket for installation of the product POWER indicator Indicates the power supply status, indicates product specifications and indicates errors. Blinks at a cycle proportional to the flow rate or indicates errors. Turns off when FLOW indicator below rated flow. Description Main screen (2-color display) Sub screen Output display (Indicator light) Unit display UP button SET button DOWN button Displays the flow, status of setting mode, and error code. Displays the accumulated flow, set value, peak/bottom value, fluid temperature, and line name. In the setting mode, the set status is displayed. (Refer to page 2 for details.) Displays the output status of OUT and OUT2. When ON: Orange light turns on. Displays the unit selected. Selects the mode and the display shown on the sub screen, and increases the ON/OFF set values. Press this button to change the mode and to set a set value. Selects the mode and the display shown on the sub screen, and decreases the ON/OFF set values. Component Parts No. Description PVC pipe 2 Seal 3 Body 4 Sensor Material CPVC FKM PPS PPS Note Replacement Parts No. Description Part no. Qty. PVC pipe ZS-4-U25 5 25 retaining plate (M5 x 8 with two hexagonal socket head cap screws) ZS-4-U25- Replacing the PVC pipe may cause accuracy to fluctuate by to 2%. 4 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Details

Series Dimensions 7-U25 Integrated display 7 23 57.6 77.4 77 54 2 x 25 (35.5) IN OUT 63 28 8 46 3 58 7 2 59 36 4 x 5.5 48 57 42 Connector pin number Example 3 4 2 Pin no. 2 3 4 Pin name DC (+) OUT2 DC ( ) OUT 4 x 3.5 depth 4 5-U25 Remote sensor unit 62.6 IN OUT ZS-4- Lead wire with M8 connector (Black) 4 (Blue) 3 M8 2 (White) (Brown) ø Pin no. Pin name Wire color 2 3 4 DC (+) OUT2 DC ( ) OUT Brown White Blue Black 5 (5) (45) (32.8) (3) Note) 4-wire type lead wire with M8 connector used for the series. ø4 Lead Wire Specifications Nominal cross WG23 Conductor section O.D. Material Insulator O.D. Color Material Sheath Finished O.D. pprox..7 mm Heat resistant PVC pprox.. mm Brown, White, Black, Blue Heat and oil resistant PVC ø4

3-color display Digital Flow Monitor for Water Series 3 3 Type 3 Remote monitor unit For remote sensor units, select the analog output to 5 V type. pplicable sensors: 5 - -(T) Output specification Symbol OUT OUT2 B C D E F G H J nalog to 5 V nalog to 5 V nalog 4 to 2 m nalog to 5 V nalog 4 to 2 m External input External input nalog to 5 V K nalog 4 to 2 m nalog 4 to 2 m In combination with remote sensor unit with temperature sensor, only OUT2 can be set for temperature sensor output. Lead wire With power supply/output connection lead wire (2 m) Nil Power supply/output connection lead wire ZS-4-W N Without power supply/output connection lead wire Lead wire is not connected, but shipped together. Options/Part No. How to Order Remote monitor unit/unit specification Symbol Instantaneous ccumulated flow rate flow Temperature M L/min L C G gal/min gal C F gal/min gal F J L/min L F Under the New Measurement Law, units other than SI (symbol: M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].2642 [gal/min] [gal/min] 3.785 [L/min] F = 9/5 C + 32 MVC Calibration certificate (Only flow monitor) Nil None With calibration certificate The certificate is written in both English and Japanese. Option 2 Nil None Sensor connector ( pc.) C Sensor connector (e-con) Connector is not connected, but shipped together. Option Nil None Panel mount adapter T V Waterproof seal (accessory) Panel Panel mount adapter Mounting screw (M3 x 8 L) (accessory) Front protective cover + Panel mount adapter Front protective cover Panel mount adapter Mounting screw (M3 x 8 L) (accessory) Waterproof seal (accessory) When optional parts are required separately, use the following part numbers to place an order. Description Part no. Note Panel mount adapter Front protective cover + Panel mount adapter Front protective cover only Power supply/output connection lead wire Sensor connector (e-con) Lead wire with connector for copying ZS-26-B ZS-26-C ZS-26- ZS-4-W ZS-28-C-4 ZS-4-Y With waterproof seal and screws With waterproof seal and screws Separately order panel mount adapter, etc. Lead wire length (2 m) pc. Connect up to slave units Panel RoHS 6 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Details

Series 3 Specifications Model Display flow range Set flow range Minimum setting unit Conversion of accumulated pulse Display unit ccuracy Repeatability Temperature characteristics ccumulated flow range Note ) Switch output Maximum load current Maximum applied voltage Internal voltage drop Response time Note 2) Output protection Output Flow rate mode Temperature Response time Note 3) nalog output Voltage output Current output Hysteresis External input Input/output Display method Indicator light Power supply voltage Current consumption Connection Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Weight Without power supply/output connection lead wire With power supply/output connection lead wire.35 to 4.5 L/min (Flow under.35 L/min is displayed as. ).35 to 4.5 L/min. L/min.5 L/pulse 3.7 to 8. L/min 3.5 to 45. L/min. L/min. L/pulse.5 L/pulse Instantaneous flow rate: L/min, ccumulated flow: L Display value: ±.5% F.S. nalog output: ±.5% F.S. ±.5% F.S. ±.5% F.S. (25 C reference) 99999999.9 L 999999999 L 7 to 2 L/min L/min L/pulse By. L By.5 L By L or open collector output 8 m 28 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current) s/2 s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. Select from hysteresis mode or window comparator mode. s/2 s (linked with the switch output) Voltage output: to 5 V Output impedance: kω Output current: 4 to 2 m Max. load impedance: 3 Ω for 2 VDC, 6 Ω for 24 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer Input for copy mode 2-screen display (Main screen: 4-digit, 7-segment, 2-color, Red/Green Sub screen: 6-digit, -segment, White), Display values updated 5 times per second Output, Output 2: Orange 2 to 24 VDC ±% 5 m or less Power supply output 5P connector, sensor connection 4P connector (e-con) IP4 (Only front face of the panel is IP65 when panel mount adapter and waterproof seal of optional parts are used.) to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between whole live part and enclosure 5 MΩ or more (5 VDC mega meter) between whole live part and enclosure CE marking, UL (CS), RoHS 5 g g Note ) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every 2 or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 24 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note 2) The response time when the set value is 9% in relation to the step input. (The response time is 7 s when it is output by the temperature sensor.) Note 3) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Temperature Sensor Specifications.7 to 8. L/min (Flow under.7 L/min is displayed as. ) 3.5 to 45. L/min (Flow under 3.5 L/min is displayed as. ) 7 to 2 L/min (Flow under 7 L/min is displayed as ) Rated temperature range Setting/Display temperature range Minimum setting unit Display unit nalog output accuracy Response time mbient temperature characteristics to C Note ) to C C C ±3% F.S. 7 s Note 2) ±5% F.S. Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9 C. Note 2) The response time is for the temperature sensor alone. nalog Output Remote sensor unit The output related to the temperature sensor is OUT2 only. Remote monitor unit DC (+) Brown Flow rate to 5 V Black Temperature to 5 V White DC ( ) Blue OUT Switch output nalog output OUT2 Switch output nalog output The OUT2 can be selected from the output for temperature or flow rate by button operation. Black OUT White OUT2 Flow rate/nalog output B C Voltage output V.5 V (.4 V) 5 V Current output 4 m 6 m (5.6 m) 2 m Values in parentheses are for the combination with the 5. Model 54 52 54 5 7 Rated flow [L/min] Minimum Maximum.5 4 2 6 5 4 Output C B Minimum rated flow Maximum rated flow Fluid temperature/nalog output Voltage output Current output Voltage output Current output.6 V 2.4 m C 5 V 2 m B V 4 m D 5.4 V 2.6 m Be sure to use in combination with remote sensor units with temperature sensor. Flow rate Output D C B C C C C Fluid temperature

3-color display Digital Flow Monitor for Water Series 3 Example of Internal Circuit and Wiring 2 Output type 3 + nalog output type 3C + nalog output type 3D Black OUT White OUT2 Gray COPY 2 to 24 VDC 2 Output type 3B + nalog output type 3E + nalog output type 3F Black OUT White OUT2 Gray COPY 2 to 24 VDC 3-Color Display Digital Flow Switch for Water + External input type 3G Black OUT White nalog output Gray COPY Black OUT White External input Gray COPY 2 to 24 VDC 2 to 24 VDC Black OUT White nalog output Gray COPY + External input type 3H Black OUT White External input Gray COPY 2 to 24 VDC 2 to 24 VDC 3-Color Display Digital Flow Switch for PVC Piping nalog 2 Output type 3J/3K Black nalog output White nalog output Gray COPY 2 to 24 VDC Sensor input circuit to 5 V (Flow rate) Black DC ( ) Blue N.C./ to 5 V (Temperature) White DC (+) Brown r e w q 3-Color Display Digital Flow Monitor for Water 3 Details 8

Series 3 Example of Internal Circuit and Wiring Wiring example of accumulated pulse output 2 Output type 3 Black OUT + nalog output type 3C/3D + External input type 3G 2 Output type 3B + nalog output type 3E/3F + External input type 3H White OUT2 (3 only) V 5 ms 5 ms Black OUT White OUT2 (3B only) V or 5 ms 5 ms When accumulated pulse output is selected, indicator light turns off. or Description (Remote Monitor Unit) Main screen (2-color display) Sensor connector Output display (Indicator light) Sub screen Unit display Power supply/ output connection lead wire Description Main screen (2-color display) Sub screen Output display (Indicator light) Unit display UP button SET button DOWN button Displays the flow, status of setting mode, and error code. Displays the accumulated flow, set value, peak/bottom value, fluid temperature, and line name. In the setting mode, the set status is displayed. (Refer to page 2 for details.) Displays the output status of OUT and OUT2. When ON: Orange light turns on. Displays the unit selected. UP button SET button DOWN button Selects the mode and the display shown on the sub screen, and increases the ON/OFF set values. Press this button to change the mode and to set a set value. Selects the mode and the display shown on the sub screen, and decreases the ON/OFF set values. Sensor connector q w e r 2 3 4 Power supply/output connection lead wire 9 Pin no. 2 3 4 5 Gray COPY White OUT2 Black OUT 2 Pin no. q w e r Terminal DC (+) N.C./IN DC ( ) INPUT Connector no. 2 3 4 Lead wire color Brown White (Not used/temperature sensor to 5 V input) Blue Black (Flow rate sensor to 5 V input) When using the lead wire with M8 connector included with the 5 series Lead Wire Specifications Nominal cross Conductor section O.D. Material WG26 pprox..5 mm Cross-linked vinyl Insulator Sheath O.D. Color Material pprox.. mm Brown, Blue, Black, White, Gray Oil and heat resistant vinyl Finished O.D. ø3.5

3-color display Digital Flow Monitor for Water Series 3 Dimensions 4 Front protective cover + Panel mount adapter 4 53 47 6 9.4 (2) 4. (7.5) 2.5 36.8 NC/IN Sensor connector (4P) Power supply/ output connector (5P) 3-Color Display Digital Flow Switch for Water Panel fitting dimmensions pplicable panel thickness:.5 to 8 mm (Without waterproof seal).5 to 6 mm (With waterproof seal) 37.5 +..2 46.4 42.4 Front protective cover Waterproof seal 37.5 +..2 4 x R or less Panel 48 or more Panel mount adapter 55 or more 3-Color Display Digital Flow Monitor for Water 3 3-Color Display Digital Flow Switch for PVC Piping Details 2

Series Details Integrated Display (Series 7)/Remote Monitor Unit (Series 3) Output operation The output operation can be selected from the following: Output (hysteresis mode and window comparator mode) corresponding to instantaneous flow rate, Output corresponding to accumulated flow, ccumulated pulse output Note) t the time of shipment from the factory, it is set to hysteresis mode and normal output. When a temperature sensor is attached, the output to the temperature sensor is selectable only for OUT2. (Refer to How to Order for details.) Indication color The indication color can be selected for each output condition. The selection of the indication color provides visual identification of abnormal values. (The indication color depends on OUT setting.) ON: Green, OFF: Red ON: Red, OFF: Green lways: Red lways: Green Response time The response time can be selected depending on the application. ( second for default setting) bnormalities can be detected more quickly by setting the response time to.5 seconds. The effect of the pump fluctuation and flickering of the display can be reduced by setting the response time to 2 seconds. Note) The temperature sensor output is fixed to 7 seconds. Response time.5 seconds second 2 seconds Integrated display Series 7 pplicable model Remote monitor unit Series 3 Selection of display on sub screen The display on the sub screen in measuring mode can be set. External input function This function can be used when external input is available. The accumulated value, peak value, and bottom value can be reset by remote control. ccumulated flow external reset: This function resets the accumulated value to when an input signal is applied. In accumulated increment mode, the value will be zero when reset, and the accumulated value will increase from zero. In accumulated decrement mode, the value will be the set value when reset, and the accumulated value will decrease from the set value. When the accumulated value is memorized, every time the accumulated value external reset is activated, the memory element (EEPROM) will be accessed. Take into consideration the maximum number of times the memory element can be accessed, million times. The total of external input times and accumulated value memorizing time interval should not exceed million times. Peak and bottom reset: Peak and bottom values are reset. Forced output function Output is turned ON/OFF compulsorily when starting the system or during maintenance. This enables confirmation of the wiring and prevents system errors due to unexpected output. For the analog output type, the output will be 5 V or 2 m for ON and V or 4 m for OFF. lso, the increase or decrease of the flow and temperature will not change the on/off status of the output while the forced output function is activated. ccumulated value hold function ccumulated value can be saved on the unit even when the power supply is turned off. The accumulated value is memorized every 2 or 5 minutes during measurement, and continues from the last memorized value when the power supply is turned on again. The lifetime of the memory element is million access cycles. Take this into consideration before using this function. Sub screen Integrated display Remote monitor unit Set value display Displays the set value. (The set value of OUT2 cannot be displayed.) ccumulated value display Displays the accumulated value. (The accumulated value of OUT2 cannot be displayed.) Peak value display Displays the peak value. Bottom value display Displays the bottom value. Line name display Displays the line name. (Up to 6 alphanumeric characters can be input.) Fluid temperature display Displays the fluid temperature. (When the temperature sensor type is selected.) OFF Displays nothing. The above are examples of integrated displays. (Same as remote monitor unit) Power saving mode The display can be turned off to reduce the power consumption. In power saving mode, decimal points blink on the main screen. If any button is pressed during power saving mode, the display is recovered for 3 seconds to check the flow, etc. Setting of secret code Users can select whether a secret code must be entered to release key lock. t the time of shipment from the factory, it is set such that the secret code is not required. 2 Peak/Bottom value indication The maximum (minimum) flow is detected and updated from when the power supply is turned on. In peak (bottom) value indication mode, this maximum (minimum) flow is displayed. Keylock function Prevents operation errors such as accidentally changing setting values.