Type: DILM12 10(24VDC) Article No.:

Similar documents
Type: DILM25 10(24V50HZ) Article No.:

Minicontactorrelay,2NO/2NC,DCoperated

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

AS09..S 3-pole Contactors - Spring Terminals

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Series CT7N Bimetallic Overload Relays

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

02/11/2015

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

A V 50Hz / V 60Hz

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Datasheet - SRB-E-201ST

Bulletin 190 IEC Modular Starter System

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Datasheet - SRB301LC 24VAC/DC

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME. Main. Device short name. Device application

Ordering details. Approval. Classification

GV2P05. Main. Device short name. Device application

GV2ME. Main. Device short name. Device application

Magnecraft Power Relays

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

High performance circuit breakers

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Manual Motor Starter Specifcations

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Data Sheet Definite Purpose Contactors Ex9CK Series

Circuit-Breakers for Motor Protection Series 8523/8

8 Installation Equipment

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

Kuhnke Technical Data. Contact Details

Pluggable interface relays CR-M Miniature relays

LED Driver Compact fixed output

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

Capacitance Limit Detection nivotester FTC 420/421/422

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

Modular pulse operated latching relay 16 A

LED Driver Compact fixed output

Power Circuit of a UL508A Panel. Typical UL489 Application

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

LED MODULES READYLINE DL

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

llen-bradley 194R-HM4-NFPA3


Pluggable interface relays CR-M Miniature relays

LED control gear Compact fixed output

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

KRF EMC Filters Installation, Operation and Maintenance Manual

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Process Transmitter RMA 422

LED Driver Compact dimming

16 A and 25 A power contactors with or without handle

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Interface Relays and Optocouplers Product group picture

Linear flow controls VFC Linear flow controls with actuator IFC

TRISHALA ELECTROLYTICS PVT LTD BANGALORE

ALLEN BRADLEY TIMING RELAY

Product Data Sheet 4656 ZW

Type Contact form Model

LED Driver Linear / area fixed output

AC1036. Definite Purpose Contactors

Transcription:

Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50 60 Hz AC 3 400 V Max. rating for three phase motors, 50 60 Hz AC 3 690 V Max. rating for three phase motors, 50 60 Hz AC 4 230 V Max. rating for three phase motors, 50 60 Hz AC 4 400 V Max. rating for three phase motors, 50 60 Hz AC 4 690 V P kw 3.5 P kw 5.5 P kw 6.5 P kw 2 P kw 3 P kw 4.4 Conventional thermal current I th = I e AC 1 Open I th = I e A 20 For use with DILM32 XHI.. DILA XHI(V).. General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated Operations 10 6 10 DC operated Operations 10 6 10 Operating frequency, mechanical AC operated Operations/h 9000 DC operated Operations/h 9000 Climatic proofing Ambient temperature Damp heat, constant, to IEC 60068 2 78 Damp heat, cyclical, to IEC 60068 2 30 1

Open C 25/60 Enclosed C 25/40 Storage C 40/80 Mechanical shock resistance (IEC/EN 60068 2 27) Half sinusoidal shock, 20 ms Main contacts Make contact g 10 Auxiliary contacts Make contact g 7 Break contact g 5 Protection type Protection against direct contact when actuated from front (IEC 536) Weight IP20 AC operated kg 0,23 DC operated kg 0,28 Terminal capacity Main cable Solid mm 2 1 (0.75 4) 2 (0.75 2.5) Flexible with ferrule mm 2 1 (0.75 2.5) 2 (0.75 2,5) Anschlussschraube Hauptleiter M3.5 Tightening torque Nm 1.2 Terminal capacity Control circuit cables Solid mm 2 1 (0.75 4) 2 (0.75 2.5) Flexible with ferrule mm2 Anschlussschraube Hilfsleiter M3.5 Tightening torque Nm 1.2 Tool Main cable Pozidriv screwdriver Size 2 Standard screwdriver Control circuit cables Pozidriv screwdriver Size 2 Standard screwdriver Terminal capacity Main cable mm mm Finger and back of hand proof 1 (0.75 2.5) 2 (0.75 2.5) 0.8 5.5 1 6 0.8 5.5 1 6 Solid mm 2 0.75 2.5 flexible mm 2 0.75 2.5 flexible with ferrules mm 2 0.75 2.5 Terminal capacity Control circuit cables 2

Solid mm 2 0.75 2.5 Flexible mm 2 0.75 2.5 Flexible with ferrule mm 2 0.75 2.5 Tool Stripping length mm 10 Screwdriver blade width mm 3,5 Main conducting paths Rated impulse withstand voltage U imp V AC 8000 Overvoltage category/pollution degree Rated insulation voltage AC U i V AC 690 Rated operational voltage U e V AC 690 Safe isolation to VDE 0106 Part 101 and Part 101/A1 between coil and contacts V AC 400 between the contacts V AC 400 Making capacity (cos Õ to IEC/EN 60947) up to 690 V Breaking capacity III/3 A 144 220/230 V A 120 380/400 V A 120 500 V A 100 660/690 V A 70 Component lifespan AC 3/AC 4 Tripping characteristics Maximum operating frequency AC 1; 400 V I e Ops/h 800 AC 3; 400 V I e Ops/h 1000 AC 4; 400 V I e Ops/h 300 Short circuit rating Short circuit protection Maximum fuse Type 2 coordination 400 V gg/gl 500 V A 20 690 V gg/gl 690 V A 20 Type 1 coordination 400 V gg/gl 500 V A 35 690 V gg/gl 690 V A 25 AC AC 1 duty conv. therm. current 3 pole 50 60 Hz open at 40 C I th A 22 at 50 C I th A 21 at 55 C I th A 21 at 60 C I th A 20 3

Enclosed I th A 18 Conventional free air thermal current, 1 pole open I th A 50 Enclosed I th A 45 AC 3 duty Rated operational current AC 3 open, 50 60 Hz, 3 pole 220/230 V I e A 12 240 V I e A 12 380/400 V I e A 12 415 V I e A 12 440V I e A 12 500 V I e A 10 660/690 V I e A 7 Motor rating 220/230 V P kw 3,5 240V P kw 4 380/400 V P kw 5,5 415 V P kw 7 440 V P kw 7,5 500 V P kw 7 660/690 V P kw 6,5 AC 4 duty Rated operational current AC 4 open, 50 60 Hz, 3 pole 220/230 V I e A 7 240 V I e A 7 380/400 V I e A 7 415 V I e A 7 440 V I e A 7 500 V I e A 6 660/690 V I e A 5 Motor rating 220/230 V P kw 2 240 V P kw 2,2 380/400 V P kw 3 415 V P kw 3,4 440 V P kw 3,6 500 V P kw 3,5 660/690 V P kw 4,4 DC of three phase capacitors open DC 1 operation 60 V I e A 20 110 V I e A 20 220 V I e A 15 440 V I e A 1,3 4

DC 3 operation 60 V I e A 20 110 V I e A 20 220 V I e A 1,5 440 V I e A 0,2 DC 5 operation 60 V I e A 20 110 V I e A 20 220 V I e A 1,5 440 V I e A 0,2 Current heat loss (3 pole) Current heat loss at I th W 4,7 Current heat loss at I e to AC 3/400 V W 1,1 Impedance per pole m& 2,5 Magnet systems Voltage tolerance AC operated AC operated Pick up U c 0,8 1,1 Drop out voltage AC operated Drop out voltage AC operated Abfall U c 0,3 0,6 DC operated DC operated Pick up U c 0,8 1,1 DC operated DC operated Abfall U c 0,15 0,6 Power consumption of the coil in a cold state and 1.0 U c 50 Hz Pick up VA 24 50 Hz Pick up W 19 50 Hz Sealing VA 4 50 Hz Sealing W 1,2 60 Hz Pick up VA 29 60 Hz Pick up W 23 60 Hz Sealing 4,4 60 Hz Sealing VA 1,3 50/60 Hz Pick up VA 50/60 Hz Pick up W 50/60 Hz Sealing VA 50/60 Hz Sealing W DC operated Pick up W 4.5 DC operated Sealing W 4.5 28 26 22 21 4,6 3,9 1,4 1,2 Duty factor % DF 100 Switching times at 100 % U c (approximate values) Main contacts 5

AC operated Closing delay ms 20 Opening delay ms 15 DC operated Closing delay ms 35 Opening delay ms 15 Arcing time ms 10 Electromagnetic compatibility (EMC) Emitted interference to EN 60947 1 Interference immunity to EN 60947 1 Mounting position Mounting position, AC and DC operated Moeller GmbH, Hein Moeller Str. 7 11, D 53115 Bonn E Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2005 by Moeller GmbH. Subject to modifications. HPL C2005GB INT V3.0 6