SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

Similar documents
SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

TECHNICAL SPECIFICATION

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

Revision No. 4 Page No. Page 1 of 7

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Micro duct Cable with HDPE Sheath for Installation by Blowing

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Number of Fiber 6 Core 12 Core. Part Number

1. General. 1. Scope. 2. Quality Assurance

Number of Fiber 12 Core 24 Core 48 Core. Part Number

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

Number of Fiber 6 Core 12 Core 24 Core 48 Core

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

SPECIFICATION. Optical Fiber Cable

Detailed Specifications & Technical Data

TENDER SUMMARY. Tender Title:

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

Ø 1000 * 588 mm 50 kg

LD Series High Performance Loose Tube Fiberoptic Cables

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

OPTICAL FIBRE CABLE NETWORK 2004/1

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

HERA RETICULATION FIBRE CABLE PRODUCT REQUIREMENTS

FREEDM Loose Tube Interlocking Armored Cables

OPTICAL CABLE FIBER-LAN INDOOR

Product Catalogue. Fibre Optic Cable

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

Empowering businesses through innovative network solutions.

Mining and Petrochemical Fiber Optic Cables

SOLO ADSS Short-Span Cables, Fibers

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

ETSI ES V1.1.1 ( )

Material Description Quantity UOM

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

Mar11 Rev E

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

Triax TechInfo. Installing and pulling Fibre Optic cables

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

ANSI/ICEA S STANDARD FOR OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

SPECIFICATION. Spec No : VSS-1402-CS603B

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

Gear up for the future.

DOME OPTIC SPLICE CLOSURE

for FOSTEC INC. 1/ 15

How to Speak Fiber Geek Article 4: Single-Mode Optical Fiber Geometries

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

We design, build, and manage web-scale networks for the needs of tomorrow. System Integration SERVICES

Polymer optical fibre as duplex fibre cable version with PCV or PUR sheath for PROFINET applications type B or C

PRO SERIES FIBRE-150M

SPECIAL SPECIFICATION 8540 Telecommunication Cable

Table of Contents. Open Matrix System (OMS) 1-2

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Fiber Optic Cable System

SPECIAL SPECIFICATION 6559 Telecommunication Cable

A Comparison of Dry Versus Gel Filled Optical Cables

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

Purchase Now ANSI/ICEA S

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

TECHNICAL SPECIFICATION

FIBRE OPTIC CABLE SOLUTIONS

Public Works Division Lighting District Fiber Optic Specifications April 2009

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

INDUSTRY SOLUTIONS: MINING

The World Of Professional Fiber Optics. safe flexible reliable

SECTION 4 TABLE OF CONTENTS

Industry solutions: Broadcast

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

Content. 1.4 Fiber Cable Assembly

HITRONIC Optical Transmission Cable

- Outdoor & Indoor Telephone Cables - Fiber Optic Cables - Electronic Control Cables - Control Cables - Data/LAN Cables - Coaxial Cables

Transcription:

Revision No.:01 Date: 07.10.06 SPECIFICATION OF 96F SM LOOSE TUBE, DRY CORE MINI CABLE PART NO.:D-96/SM/MTY(F)-MFN-O6.3 Checked By: Pavan Maheshwari Process Associate Design & Development Team Approved By: C.S. Gupta Process Associate Manufacturing Team

1. SCOPE APPLICATION This Specification covers the general requirements for Mini fibre optic telecommunication cables used for Micro duct applications. CABLE DESCRIPTION Single mode colour coded fibres, filled with thixotropic jelly colour coded loose tubes, water swellable yarn, SZ stranded around the dielectric central strength member, rip cord and outer Nylon jacket. 2. OPTICAL FIBRE 1) Manufacturing Process : VAD 2) Fibre Type : Single Mode Matched clad fibre as per ITU-T G652D (Japnese made Fiber is preferred) 3) The optical Geometrical, Mechanical and Environment performance of the optical fibre shall be in accordance with table 1 and 2 below. Table 1. The Optical and Geometrical Performance of Single Mode Fibre CHRACTERISTICS UNITS SPECIFICATION Attenuation db/km 0.38 & Average 0.35 at 1310 nm 0.25 & Average 0.21 at 1550 nm Chromatic Dispersion ps/nm.km 3.2 at 1285 nm 1330 nm 18.0 at 1550 nm Zero Dispersion nm 1302 1322 Wavelength Zero Dispersion Slope ps/nm2.km 0.092 Polarization Mode Ps/ km 0.20 Dispersion Cutt-off Wavelength nm 1260 (λcc, 22m of a cabled fibre) Point Discontinuity db 0.10 at 1310 nm & 1550 nm Attenuation at Water db/km 0.34 at 1383 ± 3 nm Peak Attenuation Vs Wavelength db/km 0.05 at 1285 nm & 1330 nm (from the 1310 nm value) 0.05 at 1525 nm & 1575 nm (from the 1550 nm value) Attenuation Vs Bending db 0.10 at 1550 nm

(60mm x 100 turns) Mode Field Diameter µm 9.3 ± 0.5 at 1310 nm 10.5 ± 1.0 at 1550 nm Core Clad Concentricity µm 0.6 Cladding Diameter µm 125 ± 0.7 Cladding Non Circularity % 1.0 Coating Diameter µm 245 ± 10 Fibre Curl m 4 Effective Group Index (Typical) - 1.4670 at 1310 nm 1.4675 at 1550 nm Table 2. The Mechanical and Environment Performance of Single Mode Fibre CHRACTERISTICS UNITS SPECIFICATION Proof Test Kpsi 100 Temperature Cycling db/km 0.05 at1310 nm & 1550 nm (-60 C to +85 C) Temperature Humidity Cycling db/km 0.05 at1310 nm & 1550 nm (-10 C to +85 C, up to 98 % RH) Water Immersion, 23 C db/km 0.05 at1310 nm & 1550 nm Heat Aging, 85 C db/km 0.05 at1310 nm & 1550 nm 3. CABLE CONSTRUCTION The construction of the cable should be in accordance with table 3. below. Table 3. Construction of The Cable ITEMS DESCRIPTION Number of Fibres 96 Type of Fibre Single Mode (ITU T G652D) No. of Fibres per Tube 12 Loose Buffer Tube Material PBT (Polybutylene Terephthalate) Loose Buffer Tube Diameter Nom. 1.5 mm Filling Compound in Loose Buffer Thixotropic Jelly Compound Tube Water Blocking Material Water Swellable Yarn around the CSM (To prevent the ingress of water) Central Strength Member FRP (Fibre Reinforced Plastic) Rip Cord One rip cord (To provide easy cable end preparation) Outer Jacket Material Nylon-12 Outer Jacket Thickness 0.4 mm nominal

4. FIBRE AND LOOSE BUFFER TUBE IDENTIFICATION The colour code of the loose buffer tubes and the individual fibres within the loose buffer tube shall be in accordance with Table 4 and 5 below. Table 4. The colour code of the Individual fibres No. of Fibres Colour of Fibre No. of Fibres Colour of Fibre 1 Blue 7 Red 2 Orange 8 Black 3 Green 9 Yellow 4 Brown 10 Violet 5 Grey 11 Pink 6 White 12 Turquoise Table 5. The colour code of the Loose Buffer Tubes No. of Loose Buffer Tubes Colour of Buffer Tube No. of Loose Buffer Tubes Colour of Buffer Tube 1 Blue 7 Red 2 Orange 8 Black 3 Green 9 Yellow 4 Brown 10 Violet 5 Grey 11 Pink 6 White 12 Turquoise 5. PHYSICAL / MECHANICAL / ENVIRONMENTAL PERFORMANCE AND TESTS The Mechanical and Environmental performance of the cable shall be in accordance with Table 6. Unless otherwise specified, all attenuation measurements required in this section shall be performed at 1550 nm. Table 6. The Mechanical and Environmental Performance of the cable TEST Tensile Loading and Bending Test Compressive Loading TEST METHOD AND ACCEPTANCE CRITERIA # Test Method :TIA/EIA-455-33A - Mandrel Diameter: 30 D (D= Cable Diameter) - Short term tensile load: 800 N for 1 hour - Long term tensile load: 400 N for 10 minutes - Fibre Strain: less than 60% of the fibre proof strain for short term tensile load - Attenuation increment : 0.10 db for long term tensile load. # Test Method:TIA/EIA-455-41A

Resistance Test - Applied Load: 220N/cm - Duration of loading:10 minutes - Attenuation increment: 0.10 db after the completion of the test Cyclic Flexing Test Cable Twist Test Temperature Cycling Test Water Penetration Test # Test Method:TIA/EIA-455-104A - Sheave Diameter: 20D (D= Cable diameter) - No. of flexing cycles: 25 cycles - Flexing speed: 30 cycles/minute - Attenuation increment: 0.10 db after the completion of the test - No jacket cracking and fibre breakage # Test Method:TIA/EIA-455-85A - Cable length twisted: 2 meter - No. of twist cycles : 10 cycles - Twist angle: 180 Degree - Attenuation increment: 0.10 db after the completion of the test - No jacket cracking and fibre breakage # Test Method:TIA/EIA-455-3A - Temperature cycling schedule: 23 C - 30 C 70 C - 30 C 70 C - Soak time at each temperature: 12 hours - Attenuation increment: 0.10 db/km # Test Method:TIA/EIA-455-82B - Length of specimen: 1 meter - Height of Pressure head: 1 meter - Test time: 24 Hours - No leakage through the open cable end 6. PACKING AND MARKING Cable Marking The jacket shall be marked with black colour inkjet printing at the intervals of every meter with following information. a. Name of manufacturer

b. Number of fibres & Cable type c. Year of manufacture d. Sequential length marking in meters Or as per purchase order Cable Packing - Standard length of cable shall be 2000 meters and 4000 meters + 5 %. Other cable length is also provided if required by customer. - Short length up to 10% of the deliveries may be shorter than 2000 and 4000 meter but never shorter than 800 meters. - Each length of the cable shall be wound on a separate wooden reel. - Both ends of the cable shall be sealed with a suitable plastic cap to prevent the entry of moisture during shipping, handling and storage. - The inner end of the cable is housed into a slot on the side of the reel without extra cable length for testing. - Circumference battens shall be secured with steel bands to protect the cable during normal handling and shipping. Cable Reel Details given below shall be distinctly marked with a weather proof material on the both outer sides of the reel flange. Other shipping mark is also available if requested by customer. - Purchaser Name - Length of cable - Number of Fibres & Size - Gross weight - Reel Number - Name of the Manufacturer - Year of Manufacture - Arrow showing the direction the drum shall be rolled. The cable shall be shipped on reels designed to prevent damage to the cable During shipment and installation.

CROSS SECTIONAL DRAWING OF CABLE OUTER SHEATH (NYLON) LOOSE TUBE WITH FIBRES CENTRAL STRENGTH MEMBER WATER SWELLABLE YARNS RIP CORD Diameter, Weight and Minimum Bending Radius No. of Fibres Cable Diameter mm Cable Weight Kg/Km Minimum Bending Radius (mm) Under Load No Load 96F 6.3 + 0.3 38 + 5 126 63 Number of loose tubes & number of fibres per loose tube No. of Fibres No. of Loose tube No. of Fibres per Loose tube 96F 8 12 12 fiber per loose tube is fixed. Rip cord is mandatory. =====================End of Specification =========================